HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE



Similar documents
powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

Boundary-breaking acoustic focusing cytometry

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

CyAn : 11 Parameter Desktop Flow Cytometer

FlowSight. Flow cytometry with vision

Introduction to flow cytometry

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Immunophenotyping peripheral blood cells

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

CyFlow Space Your flexible flow cytometer

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

Easy to use. Compact. Flexible. Sorting Chip

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Introduction to Flow Cytometry

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

NovoCyte Flow Cytometer Operator s Guide

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

BD FACSComp Software Tutorial

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8

APPLICATION INFORMATION

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

Introduction to Flow Cytometry

These particles have something in common

COMPENSATION MIT Flow Cytometry Core Facility

Standardization, Calibration and Quality Control

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Science is hard. Flow cytometry should be easy.

Standard Operating Procedure

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Cytell Cell Imaging System

Attune NxT Acoustic Focusing Cytometer

Principles of Flowcytometry

flow cytometry reinvented

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Uses of Flow Cytometry

FACSCanto RUO Special Order QUICK REFERENCE GUIDE

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

How to operate the BD FACSCanto flow cytometer

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

Let the BD FACSAria II accompany your best performance ever

Flow cytometry basics fluidics, optics, electronics...

UCHC Guide to CellQuest Pro. FACS Calibur instruments

Three Rules for Compensation Controls

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

Institut für Experimentelle Immunologie und Bildgebung

Cell Cycle Tutorial. Contents

INSIDE THE BLACK BOX

Introduction to Flow Cytometry:

BD FACSVerse. Simply brilliant

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Attune Acoustic Focusing Cytometer

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

LSR II Users Guide Stanford Shared FACS Facility 06/10/13

Establishing Optimum Baseline PMT Gains to Maximize Resolution on BD Biosciences Digital Flow Cytometers

ArC Amine Reactive Compensation Bead Kit

Compensation Controls Data Visualization Panel Development Gating Quantum Dots

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

FACS Laboratory. BD LSRs Operator Training. Training Guide.

BD FC Beads 8-Color Kit for BD OneFlow Assays

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection

TROUBLESHOOTING FLOW CHART

Below is a list of things you should be aware of before you schedule your sort.

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

Zecotek S Light Projection Network Marketing

UV-Vis spectrophotometers

EDF Extended Depth of Field

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

Application Note. Single Cell PCR Preparation

Setting up and calibration of a flow cytometer for multicolor immunophenotyping

Agilent Cary 60 UV-Vis

Partec PAS. Your Flow Cytometer.

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

guava Flow Cytometry easycyte Systems

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

EdU Flow Cytometry Kit. User Manual

Flow Cytometry A Basic Overview

Analyzer Experiment setup guide for LSRII and Canto s

Welcome to More Choice BD Analyte Specific Reagent (ASR) Catalog

Flow Cytometry. flow cytometer DNA apoptosis ph

CyAn ADP with Summit Software User Guide

Cell Sorting. S3e Cell Sorter Quick Guide

Becton-Dickinson FACSCalibur Flow Cytometer Instructions

Transcription:

POWERFUL. INTUITIVE. CUSTOMIZABLE. HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE

ABOUT ACEA Established in 2002, ACEA Biosciences, Inc. develops cutting-edge cell analysis platforms for life science research. More than 1,000 ACEA cell analysis instruments are being used by scientists around the world for a wide range of biological research and drug discovery applications. ACEA released their real-time, label-free xcelligence System in 2008, and continues to develop new technology. To help ensure success of our customers and their applications, ACEA provides exceptional customer service and expert technical support.

NOVOCYTE A HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE Address the full range of current and future multi-parameter cellular analysis research needs with the NovoCyte flow cytometer. ACEA brings researchers high performance flow cytometry at a low investment cost with the NovoCyte platform. ACEA offers a system which is: Powerful - up to 15 parameter detection with enhanced sensitivity and resolution. Intuitive - automated instrument maintenance functions and advanced data analysis capability for greater usability. Customizable - 1 to 3 laser options, exchangeable filters, multiple sampling options and flexible analysis formats. HIGH PERFORMANCE LOW COST

KEY INSTRUMENT FEATURES Optimized PMT Voltage & 24 Bit Detection Dynamic Range Provides 10 7 dynamic range for signal detection and processing, offering a broader signal range than other flow cytometers. Wide range of fluorescence and scattering signal intensities eliminates the need for complicated and laborious PMT voltage adjustment. Data acquisition is simply load-and-go. Volumetric Fluidics System for Increased Accuracy & Easy Maintenance Direct absolute counting, no need for addition of counting beads. Accurate pressure sensors monitor fluidic status in real-time, providing warning messages at abnormal high pressures due to possible flow path obstruction. Automated fluidic functions maintain the instrument at an optimum status, allowing for reliable and accurate data acquisition. Automated SIP (sample injection probe) washing following sample acquisition minimizes sample carryover and increases capability to detect rare events. High speed data acquisition of up to 35,000 events per second. 1

Configurable Fluorescence Detection Channels for Enhanced Assay Flexibility Customizable selection and upgrade with lasers of different wavelengths allow for personalized, versatile choices of fluorochromes for flow cytometry assays. User interchangeable filters and dichroic mirrors broaden available fluorescence channels to expand users detection options. 13 Fluorescence Channel Detection: Multiple Laser Options Providing Flexibility of Choice (405nm, 488nm, 640nm) Customize the instrument to meet detection needs with blue, red and violet laser options. System can be upgraded as analytical requirements increase no need to purchase another instrument. State-of-the-art solid-state lasers provide high quality and extremely stable optical illumination. Novel Optical Design & Enhanced Signal Detection Patent pending independent beam shaping optics and light collection system maximizes signal detection efficiency, increasing sensitivity and resolution for each fluorescence channel. Fixed optical alignment removes need for daily maintenance and adjustment of optical system, providing convenient operation and superior long-term stability. Optimized forward scatter obscuration bar increases sensitivity. Enhanced small particle detection and resolution as a result of optimized obscuration bar design. 2

KEY SOFTWARE FEATURES Experiment Analysis Design Experiment Manager provides a schematic view of the sample analysis being performed. This allows for access to cytometer settings, compensation matrix, report generation and data analysis. Multiple samples can be analyzed with the same settings by a simple drag-and-drop template function. Automated & Versatile Data Analysis Functions Powerful NovoExpress software allows efficient data acquisition, data analysis and report generation. NovoExpress software provides flexible analysis templates and plotting tools, offering enhanced data analysis efficiency. 3

Pre & Post Acquisition Compensation In addition to automated compensation, instantaneous compensation results results can be simply achieved by adjustment of the compensation scaling bar on the plot, allowing rapid and accurate compensation, thus eliminating tedious trial and error adjustments of compensation matrix coefficients. Before Quick Compensation Scaling Bar After Quick Compensation Quick Compensation Plots Rapid Import & Export of Data Files FCS (Flow Cytometry Standard) 3.0 files can be imported for analysis by NovoExpress. Data can also be exported as a FCS 3.0 file for further analysis in a 3rd party software, or as a CSV (Comma Separated Value) file for analysis in programs such as Microsoft Excel. The NovoCyte's volumetric precision pump enables direct absolute counting without the need for reference counting beads. One click enables the concentration of your sample to be calculated. 4

NOVOCYTE PROVIDES OUTSTANDING PERFO High Sensitivity & High Resolution Detection Highly efficient light collection ensures reliable detection of sub-micron particles and dim signals. Using innovative optical design for light collection and high quality PMTs, fluorescence signals are efficiently detected with an exceptionally high signal-to-noise ratio, ensuring a high detection sensitivity for weak positive samples and small particles. Bangs Laboratories NIST Traceable Particle Size Standards High Fluorescence Signal Resolution Improves Detection Accuracy Advanced optical and fluidic system design, premier quality components, and innovative signal processing algorithms collectively ensure accurate extraction of detection parameters with consistently low variation. Spherotech 8-peak Rainbow Beads Volume-Based Direct Absolute Counting, No Additional Counting Beads Required With a high accuracy syringe pump controlling the injected sample volume and minimal cell loss in the fluidics, the NovoCyte flow cytometer achieves accurate direct cell counting without the need for expensive counting beads. 5

RMANCE Powerful signal detection and data analysis capabilities, and a user friendly software interface guarantee fast, economic, and accurate flow cytometry data generation and reliable data analysis. Immunophenotyping Immunophenotyping quickly identifies candidate cell types, sub-classes and functions. The ACEA NovoCyte flow cytometer can be used for multi-parameter lymphocyte sub-population counting and phenotyping, helper T lymphocyte differentiation and functional study, new sub-population identification, disease-specific sub-population identification, and cell surface marker detection. T Subsets Analysis T/B/NK Phenotyping Lymphocyte sub-population analysis: Normal human peripheral blood was stained with T subset (CD3/CD4/CD8/CD45) or T/B/NK (CD3/CD19/CD16+56/CD45) cocktails with RBCs lysed using RBC lysis solution. 6

NOVOCYTE PROVIDES OUTSTANDING PERFO 10-Color Analysis of T Cell Subpopulations Understanding the function and interaction of the molecular and cellular components of the immune system demands multiparameter analysis. The NovoCyte flow cytometer, with its innovative optical detection design, can simultaneously detect up to 15 parameters in a single experiment, enabling identification and detailed study of subpopulations of cells in blood samples. A B C D F E G CD4 + cell subpopulations analysis: Normal human whole blood was stained with a cocktail of 10 mabs (see Table 1). Cells were analyzed on ACEA NovoCyte TM 3000 (Cat#2010011). In this figure, CD4 + T lymphocytes (lower right quadrant of Plot C) were further analyzed. CD4 + Treg cells express high levels of CD25 and low levels of CD127 (Plot D). The CD45RO - RA + (upper left quadrant of Plot E) population generally represents naïve/effector CD4 + T cells, which can be further divided into naïve T and effector T cells based upon different levels of CD62L and CCR7 expression (Plot F). CD45RO + RA - cells are mainly activated T cells and memory T cells (lower right quadrant of Plot E). The memory T cells can be further divided into central memory T cells and effector memory T cells by analyzing expression levels of CD62L and CCR7 (Plot G). 7

RMANCE (CONTINUED) Antibody Specificity Format Laser (Excitation) FL Channel on NovoCyte Filter (Emission) CD25 BV421 405nm VL1 445/45 CD3 BV510 405nm VL2 530/30 Table 1. Expanded Detection Channel Capabilities with 3-Laser System: This table summarizes the 10-color experiment antibody combination using the NovoCyte three laser system which includes 4 colors of the 405nm laser, 4 colors of the 488nm laser and 2 colors of the 640nm laser. CCR7 BV650 405nm VL5 675/30 CD45RA BV785 405nm VL6 780/60 CD4 FITC 488nm BL1 530/30 CD127 PE 488nm BL2 585/40 CD8 PerCP 488nm BL4 675/30 CD45RO PE-Cy7 488nm BL5 780/60 CD62L APC 640nm RL1 675/30 CD45 APC-Cy7 640nm RL2 780/60 Cell Cycle Analysis Normal human somatic cells are diploids containing a constant amount of DNA. During cell cycle progression, DNA synthesis results in a doubling of total DNA content, followed by restoration of the normal DNA content after mitosis. With the NovoCyte flow cytometer, detailed cell cycle analysis can be performed to understand tumor cell differentiation, cell transformation and cell-compound interaction. A549 cell cycle analysis with PI: After treatment with 10 μm MG132 or 500μM 5-FU for 16 hours, A549 cells were analyzed for cell cycle distribution with the ACEA Novocyte flow cytometer. With the NovoExpress built-in cell cycle analysis module, the plot shows cells in G0/G1 phase (green), S phase (yellow), and G2/M phase (blue). Compared to normal untreated cells, MG132 treated cells were arrested at G2/M phase, while 5-FU treated cells were arrested at G0/G1 phase. 8

IMPROVED EASE OF USE Convenience of Operation & Maintenance With accurate pressure sensors monitoring fluidic status in real-time, the possibility of flow path obstruction is greatly reduced, allowing for reliable and accurate data acquisition. Automated cleaning and de-contamination functionality simplifies routine maintenance. A simple click of a button initiates the automated cleaning and de-contamination process and effectively removes any residual samples in the fluidics path, saving users valuable time from laborious manual cleaning and decontamination routines. Levey-Jennings 报 告 操 作 者 :User1 报 告 日 期 :2014-3-4 17:33:07 QC 测 试 微 球 批 号 :FC3MV002 软 件 版 本 :1.0.0.1307 仪 器 序 列 号 :451131110197 FSC-H CV FSC-H MFI 2.00% 400,000 1.60% 320,000 1.20% 240,000 CV MFI 0.80% Automated instrument QC test provides information on day-to-day performance of the 0.40% 80,000 NovoCyte. QC analysis only takes a couple of minutes to run, providing user reassurance. 160,000 0.00% 0 2014-2-16 2014-2-20 2014-2-24 2014-2-28 2014-3-4 2014-2-16 2014-2-20 2014-2-24 2014-2-28 2014-3-4 2014-2-18 2014-2-22 2014-2-26 2014-3-2 2014-2-18 2014-2-22 2014-2-26 2014-3-2 BL1-H CV BL1-H MFI Integrated Quality Control 2.00% 1.60% 1,000,000 800,000 The Levey-Jennings plots allow display of daily cytometer QC results over time. CV 1.20% 0.80% 0.40% MFI 600,000 400,000 200,000 0.00% 2014-2-16 2014-2-20 2014-2-24 2014-2-28 2014-3-4 2014-2-18 2014-2-22 2014-2-26 2014-3-2 0 2014-2-16 2014-2-20 2014-2-24 2014-2-28 2014-3-4 2014-2-18 2014-2-22 2014-2-26 2014-3-2 BL2-H CV BL2-H MFI 2.00% 300,000 1.60% 240,000 CV 1.20% 0.80% 0.40% 0.00% 2014-2-16 2014-2-18 2014-2-20 2014-2-22 2014-2-24 2014-2-26 180,000 Autosampler Option for High-Throughput Analysis of Multiple 60,000 Samples 0 Modular 2014-3-4 autosampler 2014-2-16 is compatible 2014-2-20 2014-2-24 with 2014-2-28 sample 2014-3-4 2014-3-2 2014-2-18 2014-2-22 2014-2-26 2014-3-2 tubes (24 tubes) and 24/96 well plates, allowing for versatile loading modes and increased throughput. 2014-2-28 MFI 120,000 1 9

SUPPORTING YOUR RESEARCH Technical Support Our skilled technical support team is available to provide field- or phone-based assistance. As highly qualified flow cytometry experts, our support team will address your needs in both NovoCyte and application support. Warranty ACEA ensures success in your research by providing technical expertise and knowledge in maintaining the high level performance of your NovoCyte system. Our technical team provides reliable service to maintain productivity, accuracy and high performance throughout the instrument s life cycle. Full Warranty and Extended Warranty includes: One PM during a twelve-month period, includes One (1) One-Year Fluidic System Maintenance Kit Software Revisions that are released during the Agreement term Unlimited service visits during the term of the agreement 48-hour guaranteed response to a request for emergency on-site service Unlimited telephone support for instruments will be provided at no additional charge ACEA NOVOCYTE COMPATIBLE FLUOROCHROMES 405nm 488nm 640nm FL Channel Pacific Blue TM 445/45 530/30 585/40 615/24 675/30 780/60 Brilliant Violet TM 421 DAPI AmCyan Brilliant Violet TM 510 Pacific OrangeTM Brilliant Violet TM 570 Qdot 605 Brilliant Violet TM 605 Qdot 655 Brilliant Violet TM 650 Qdot 800 Brilliant Violet TM 785 FITC Alexa Fluor 488 GFP PI PE PE-Texas Red PE-Alexa Fluor 610 PE-Cy TM 5 PerCP 7-AAD TM PE-Cy 7 APC Alexa Fluor 647 TM APC-Cy 7 Alexa Fluor 700 * Contact ACEA or your local distributor for complete compatibility list 10

NOVOCYTE SPECIFICATIONS Model Number 1000 2000 2060 3000 Specification 488 nm 488 nm 640 nm 488 nm 640 nm 405 nm 488 nm 640 nm 445/45 nm Detectors 530/30 nm 585/40 nm 615/24 nm 675/30 nm Sampling Data Processing Fluidics Optics 780/60 nm Laser Configuration Spatially separated beams with 10 x 80 μm elliptical spots Optical Alignment Procedure Fixed, no operator alignment required Flow Cell 170 x 290 μm rectangular quartz flow cell FSC/SSC Resolution FSC: < 0.5 μm; SSC: < 0.2 μm Cell Size 0.2-50 μm Fluorescence Threshold Sensitivity FITC < 75 MESF; PE < 50 MESF Fluorescence Resolution < 3% CV for CEN Filters User Exchangeable Sample Acquisition Rate 35,000 events/second Volumetric Absolute Count Precision CV < 5% Sample Flow Rate 5-120 μl/min Sheath Flow Rate 6.5 ml/min Sample Aspiration Volume 10-100 μl Fluid Container Capacity 3 L sheath, 3 L waste, 500 ml cleaning, 500 ml decontamination Carryover < 0.1% Fluidics Maintenance Automated startup, cleaning, decontamination and shutdown Parameters Height and Area for FSC, SSC and all Fluorescence Channels, Width and Time Dynamic Range 24 bit; 7.2 decades logarithmic scale; no need for PMT voltage adjustment Compensation Full inter-beam matrix, during or post acquisition Output Data Files FCS 3.0; CSV; Batch Reports Computer Operating System Microsoft Windows 7 Professional (64 bit) Software ACEA NovoExpress TM Manual Sample Loading 12 x 75 mm tube Automatic Sample Loading Optional - compatible with 12 x 75 mm tube, 1.5 & 2mL tubes, 24-well and 96-well microtiter plates Operating Conditions Instrument Dimension (W X D X H) Instrument Weight Power Requirements Environment Requirements 23.6 x 17.7 x 15.4 in (60 x 45 x 39 cm) 86 lb (39 kg) 100/115/230 VAC, 50-60 Hz Temperature: 15-32 C ; Relative Humidity: 80% maximum 11

ORDERING INFORMATION Instrument - Includes Workstation & NovoExpress Software Model Laser Configuration Description Catalog Number ACEA NovoCyte 1000 Blue Laser (488 nm) 3 color, FSC, SSC 2010001 ACEA NovoCyte 2000 Blue / Red Laser (488/640 nm) 4 color, FSC, SSC 2010002 ACEA NovoCyte 2060 Blue / Red Laser (488/640 nm) 6 color, FSC, SSC 2010004 ACEA NovoCyte 3000 Blue / Red / Violet Laser (488/640/405 nm) 13 color, FSC, SSC 2010011 Accessories, Reagents and Kits Description Catalog Number ACEA NovoSampler TM 2020001 NovoCyte QC Particles (2ml; 50 tests) 8000001 NovoCyte 1-Year Fluidic System Maintenance Kit 2030006 NovoCyte 6-Month Fluidic System Maintenance Kit 2030008 NovoFlow Sheath Fluid (1X; 10L) NovoFlow Sheath Fluid (6X; 10L) NovoClean Solution (1X; 500mL) NovoClean Solution (5X; 500mL) NovoRinse Solution (1X; 500mL) NovoRinse Solution (5X; 500mL) 875B601 876B601 872B602 873B602 872B603 873B603 Extended Warranties - Service Contract Options Description Catalog Number One-Year Extended Service Warranty for NovoCyte One-Laser System 2040003 Two-Year Extended Service Warranty for NovoCyte One-Laser System 2040004 One-Year Extended Service Warranty for NovoCyte Two-Laser System 2040005 Two-Year Extended Service Warranty for NovoCyte Two-Laser System 2040006 One-Year Extended Service Warranty for NovoCyte Three-Laser System 2040007 Two-Year Extended Service Warranty for NovoCyte Three-Laser System 2040008 12

Corporate Headquarters ACEA Biosciences Inc. 6779 Mesa Ridge Road Ste 100 San Diego, CA 92121 t 858.724.0927 f 858.724.0928 toll-free 866.308.2232 www.aceabio.com For life science research only. Not for use in diagnostic procedures. 2014 ACEA Biosciences, Inc. All rights reserved. NovoCyte, NovoExpress, NovoFlow, NovoClean, NovoRinse, xcelligence, and ACEA Biosciences are trademarks of ACEA Biosciences, Inc. in the US and other countries. All other product names and trademarks are the property of their respective owners.