NFPA Combustible Dust Compliance and the Industrial Ventilation System



Similar documents
WEEKLY SAFETY MEETING All Euramax Subsidiaries COMBUSTIBLE DUST. Safety Meeting Contents. Meeting Notice. Leaders Guide.

During Various Aluminum Fabricating Operations

Combustible dust. How to use this guide. Combustible Dust

9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration

Combustible Dust - Things that go Boom. W. Jon Wallace, CSP, MBA Workplace Group, LLC O: E: jwallace@workplacegroup.

Combustible Dust. Overview

Combustible Dust Ensuring Safety and Compliance. Brian Edwards, PE Conversion Technology Inc. ENVIRONMENTAL & SAFETY CONSULTING ENGINEERS

COMBUSTIBLE DUST in the WOOD PRODUCTS INDUSTRY

COMBUSTIBLE DUST EXPLOSIONS

Combustible Dust: - The Basics You Need to Know. Presented by: Mary Ann Heaney, CIH, CSP ohsm, llc.

AIHA Professional Development Conference by Daniel Brechko, Managing Consultant

Explosion Prevention

Designing your dust collection system to meet. triangle: fuel (combustible dust), an ignition source, and

Assessing the Potential for a Dust Explosion and Navigating the Current Regulatory Environment

ARE YOU IN COMPLIANCE WITH THE OSHA COMBUSTIBLE DUST DIRECTIVE? Revised March 18, 2009

Anew combustible dust standard from the National. Get ready for NFPA 652: The new combustible dust standard

Illinois Manufacturers Best Practices January 2016 Webinar

The Status of Combustible Dust Regulation

Dust Collector Fire and Explosion Highlights Need for Combustible Dust Considerations In System Designs

How to be Sure Your Dust Collector Design and Installation are NFPA Compliant. Presented by: Jeff Kice Kice Industries, Inc.

Chapter 12 Industrial Ventilation

Chemical Fume Hoods. Environmental Health and Safety

Combustible Dust CAN HURT YOU

Key Safety Issues for Combustible Dust Handling. By Molly R. Myers, P.E. Senior Safety and Risk Management Consultant

Electrical Classification

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

DRYER VENTING SPECIFICATIONS DRYER SAFETY

INVESTIGATION REPORT COMBUSTIBLE DUST HAZARD STUDY KEY ISSUES: U.S. CHEMICAL S AFETY AND H AZARD INVESTIGATION BOARD FEDERAL REGULATIONS

Combustible Dust Basics

Spray Booth Guideline

Combustible Dust Booklet

VAV Laboratory Room Airflow The Lowdown on Turndown

Compressed Gas Cylinder Program

12.85 Enforcement and Consultation Guidance for Combustible Dust Hazards December 30, 2008

On-Demand Ventilation Energy Saving in Industrial Applications

Approval Standard for Fume Exhaust Ducts or Fume and Smoke Exhaust Ducts

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Commercial Kitchen Fire Safety

A Guide to ICC Spray Booth Codes

deflagration fire marshal pmax wood rubber sugar explosion protection kst

Principles of Ventilation. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Geismar Site Reviewed: 07/05/16 Effective: 07/05/16 Supersedes: 08/04/14 Preparer: Owner: Approver: S/IH Team Leader S/IH Team Leader Manager LA Hub

Safety Data Sheet for Whole Grain

SPECIAL APPLICATIONS

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Guardian Fire Safety Solutions FIRE RISK CONTROL IN WELDING FUME EXTRACTION SYSTEMS

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Combustible Dust Hazards

Downflo workstation DuSt ColleCtorS

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Exhaust Calculation Booklet

Safe Method: Gas Safety in Catering Establishments

Combustible Dust. The Basics. Presented by: Mary Ann Heaney, CIH, CSP ohsm, llc.

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

SAFE TRANSFER OF POWDERS INTO FLAMMABLE LIQUIDS David E. Kaelin Sr., Senior Process Safety Specialist

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance

Combustible Dust Fire and Explosion Protection:

Pulverized Coal Pipe Testing and Balancing

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

PANDA SPRAY BOOTH FILTER INFORMATION

Course Title: Safety Issues in Electronics Engineering Technology Number of Credits: 3 B.A. B.S. B.A.S A.A. A.S. Degree Type

Asbestos Work Permit Procedures

To provide guidelines for the safe inspection of potential combustible worksites and for the safe collection and shipment of combustible dust

Reducing Injury and Damage Related to Electric Dryer Fires. Fire Containment Tests for the Second Edition of UL 2158

Meeting OSHA Recommendations for Combustible Dust

Effective Spray Painting Booth/Room Provided by Harleysville s Risk Control Department ext

Dust Explosion Fundamentals: Ignition Criteria and Pressure Development

HVAC Code Requirements

Remediation of Water-Based Drilling Fluids and Cleaning of Cuttings

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

99/92/EC (ATEX 137) USE

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

Elkhorn Construction, Inc. Safety Manual Title: Sandblasting Safety Policy Effective Date:

Is This Combustible Dust?

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

Requirements for Hydrogen Storage and Use

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Combustible Dust in the Workplace An overview of its recognition, evaluation, and control

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

1.2 Refrigerant Equipment. General

Efficient Pneumatic Conveying Dense Phase vs. Dilute Phase: How Being Accurate is More Cost Effective Than Being Conservative

Best Practices for Handling Nanomaterials in Laboratories

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Iron and Steel Manufacturing

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems

Guidelines for Mold Remediation (Removal)

Combustible Dust Seminar. Paul M. Sullivan, CIH Compliance Supervisor NCDOL/OSH Division - Charlotte Field Office (704)

Transcription:

NFPA Combustible Dust Compliance and the Industrial Ventilation System Presented By: Tom Kroeger PE tkroeger@kirkblum.com Kirk & Blum, a CECO Environmental Company Marty Schloss PE marty.schloss@schlossengineering.com Schloss & Associates PLLC Advantages of a NFPA Combustible Dust Program Provide a safe work environment to protect workers. OSHA, Insurance Companies, and local building officials are enforcing what used to be recommendations and now are Enforceable Standards. Focus of OSHA has changed with the Combustible Dust National Emphasis Program (NEP). Enforcement has begun utilizing the General Duty Clause. Minimize production interruptions and protect capital equipment. 1

NFPA Combustible Dust and the Importance of Capture The most cited OSHA violations involving NFPA combustible dust compliance is housekeeping primarily from lack of or inefficient capture. 1/32 of combustible dust accumulation on building surfaces may be enough dust to fuel a secondary explosion. Over 90% of combustible dust explosion fatalities are the result of secondary explosion caused material buildup due to housekeeping or capture. Plastic Molding Manufacturer North Carolina 2003 Polyethylene Powder 6 workers killed Hundreds of injuries Plant destroyed Facility was the major employer in area 2

Acoustic Board Manufacturer Kentucky 2003 Phenolic Resin Dust 7 workers killed 37 Injuries Aluminum Casting Facility Indiana 2003 Aluminum Dust 1 worker killed Several Injuries 3

Industrial Facility 2008 Sugar Dust 14 workers killed 38 Injuries Milling and Packaging Dust Fires and Explosions Like all fires, a dust fire occurs when fuel (the combustible dust) is exposed to heat (an ignition source) in the presence of oxygen (air). Removing any one of these elements of the classic fire triangle (Figure 1) eliminates the possibility of a fire. Fuel Ignition Figure 1 Oxygen Classic fire triangle 4

Dust Fires and Explosions A dust explosion requires the simultaneous presence of two additional elements dust suspension and confinement (Figure 2). Suspended d dust burns more rapidly and confinement allows for pressure buildup. Removal of either the suspension or the confinement elements prevents an explosion, although a fire may still occur. Fuel Ignition Dispersion Confinement Oxygen Figure 2 Dust Explosion Pentagon Explosion Types A primary dust explosion occurs when a dust suspension within a container, room, or piece of equipment is ignited and explodes. A secondary explosion occurs when dust accumulated on floors or other surfaces is lifted into the air and ignited by the primary explosion. Depending on the amount of dust in the area, a small deflagration or primary explosion may cause very powerful secondary dust explosions. A secondary dust explosion may follow a primary nondust explosion (e.g., natural gas, pressure, vessel, etc.). 5

Secondary Explosion The Typical Explosion Event Initial Internal Deflagration Process Equipment 0 25 50 75 100 125 150 175 200 225 250 300 325 Time, msec. 6

The Typical Explosion Event Initial Internal Deflagration Shock Wave Process Equipment 0 25 50 75 100 125 150 175 200 225 250 300 325 The Typical Explosion Event Initial Internal Deflagration Elastic Rebound Shock Waves Process Equipment 0 25 50 75 100 125 150 175 200 225 250 300 325 Time, msec. 7

The Typical Explosion Event Initial Internal Deflagration Dust clouds caused by Elastic Rebound Process Equipment 0 25 50 75 100 125 150 175 200 225 250 300 325 Time, msec. The Typical Explosion Event Containment Failure from Initial Deflagration Dust Clouds Caused by Elastic Rebound Process Equipment 0 25 50 75 100 125 150 175 200 225 250 300 325 Time, msec. 8

The Typical Explosion Event Dust Clouds Caused by Elastic Rebound Process Equipment Secondary Deflagration Initiated 0 25 50 75 100 125 150 175 200 225 250 300 325 Time, msec. The Typical Explosion Event Process Equipment Secondary Deflagration Propagates through Interior 0 25 50 75 100 125 150 175 200 225 250 300 325 Time, msec. 9

The Typical Explosion Event Secondary Deflagration Vents from Structure 0 25 50 75 100 125 150 175 200 225 250 300 325 Time, msec. The Typical Explosion Event Secondary Deflagration Causes Collapse and Residual Fires 0 25 50 75 100 125 150 175 200 225 250 300 325 Time, msec. 10

Exhaust System Components I. Hood Design 11

I. Hood Design Hoods are where system design begins We must understand d the process to determine most effective hood design Common hood configurations include canopy, side draft, or connection to a process Hood design dictates how much air we have to transport to provide worker protection Adding enclosures reduces volume of air needed to control a contaminant. 12

Covers on conveyor belts and similar material handling equipment reduces needed air volume and improves collection. Velocity Definitions 13

Velocity Definitions V 1 = Capture Velocity This is what is required to turn the contaminant stream and draw it into the system. Typical range of capture velocities is 100 500 ft/min Capture velocity required and distance to work determine volume. Velocity Definitions V 2 = Face Velocity This is simply the velocity of the air where it enters the system. Typically 150-250 for a canopy, 2000 ft/min for a slot. Does not contribute to capture! 14

Velocity Definitions V 3 = Conveying Velocity 3 This is the speed at which you transport the contaminant to the collection device. It is critical to system performance. If it s too low, settling and plugging of ductwork occur. If it s too high, excess wear occurs, and the system energy requirements will be high. Typical Conveying Velocities MUA, HVAC Mist, Fumes Industrial dust 1500-2500 ft/min 2500-3500 ft/min 3500-4500 ft/min Metal dust, Cement 4500-5500 ft/min 15

NFPA Combustible Dust and Conveying Velocities NFPA combustible dust regulations require conveying velocities be maintained in all sections of the ductwork to eliminate fuel in case of an explosion. II. Ductwork Design 16

Ductwork Design - Airflow Effective airflow design saves energy, reduces wear, and lowers operating cost. Examples of good construction: Long radius elbows Small angle branch entries Gradual tapers and hood entries Ductwork Design - Construction Construction is critical Shape Pressure Gauge Design Span Reinforcing Wear Corrosion You pay for good ductwork once; you pay operating costs again and again over the entire life of the system. NFPA Combustible Dust Compliance and the Industrial Ventilation System 17

NFPA Combustible Dust and Ductwork Design NFPA regulations require a total system design review be performed when additional equipment is added or removed to ensure conveying velocities are maintained. Ductwork between filtration equipment (baghouse) and the process or room return must have explosion isolation devices. III. Collection Devices Baghouse Cloth Bag Filter Cartridge Filter Wet Scrubbers Impingement Packed Tower Electrostatic Precipitators 18

Baghouse Application Most collector styles will work on most applications, if properly applied Collector capacity varies with dust type and loading Collector is selected after system is designed and volume is selected Baghouse Application Two Main Parameters Air-to-Cloth ratio 19

Air-to-Cloth Ratio - Definition Cubic Feet of Air Per Minute (CFM) Square Feet of Cloth Media Ft 3 /min Ft 2 = Ft/min Air-to-Cloth Ratio = Filtering Velocity Appropriate Air-to-Cloth Ratios Industrial Dust, Foundry Sand, Moderate Loading 5.5/1 Sand Systems, Finishing Systems, Heavier Loadings 5.0/1 Furnace Fume, Melt Systems, Ultra Fine Particulate 4.0/1 20

Baghouse Application Two Main Parameters Air-to-Cloth ratio Can Velocity Baghouse Application Can Velocity Can Velocity is the upward velocity in the collector housing. 21

Can Velocity Calculation Can Velocity Calculation Net can area is gross housing cross section, less circular area of filters. Gross Housing Area = 200 ft 2 400 bags, 6 dia., = 78.6 ft 2 Net Can Area = 121.4 ft 2 Q/A = V can 22

Approximate Can Velocities Heavy Dust, Moderate Concentration Lighter Dust, or Heavier Concentration Very Light Fine Dust, Difficult Applications 350 ft/min max 300 ft/min max 250 ft/min max Baghouse Pulsing Systems Time Based on fixed interval Demand Based on Pressure Drop IntelliPulse (Pressure Holding)- Computer controlled to minimize air usage 23

Baghouse Pulsing Minimizing pulsing is the goal Saves compressed air Reduces bag wear Protects filter cake Reduces emissions Combustible Dust and the Baghouse The baghouse are the perfect host for a combustible dust explosion. All five components of the explosion pentagon are present : Fine particulate makes up the dust cake on the bag. Filter pulse systems disperse the fine dust in a dense cloud above the Minimum Explosive Concentration (MEC) Air is conveying medium Sparks and fires from process machines are common occurrence. The filter enclosure provides a means of containment NFPA Combustible Dust Compliance and the Industrial Ventilation System 24

What About the Dust? You get a lot of dust. That 50,000 CFM system from earlier is delivering 428 lbs. of dust per hour, 3,424 lbs. per 8 hr shift! Dust removal is critical to collector operation Screw conveyor and rotary valve run all the time No storage in the hopper! Future Baghouse Requirements Historical emission level was.01 gr/cf MACT standard for existing facilities is.005 gr/cf MACT standard for new facilities is.001 gr/cf Improvements come from application, filter media, and pulse management 25

Good installation is no longer enough Performance must be proven at startup Performance must be monitored MACT requirements are in effect for most industries OSHA is enforcing NFPA regulations for combustible dust IV. Exhaust Fan Air Flow Static Pressure Accessories 26

IV. Exhaust Fan IV. Exhaust Fan 27

IV. Exhaust Fan IV. Exhaust Fan Energy Conservation Need high static for system to work long term Good duct design lowers static pressure requirements Efficient Hood design lowers volume requirements Conservative dust collector application lowers pressure drop Retrofitting an existing system with explosion isolation may add additional static pressure requirements. 28

V. Makeup Air Integral component to facility air quality Your building is always in balance, even without makeup air Much can be done with unheated makeup air correctly distributed NFPA Combustible Dust Regulations and Makeup Air NFPA Regulations may not allow the filtered air to be returned to the space. If allowed the air must be filtered to 99.9% efficient at 10 μm and the energy from a combustible dust explosion be removed 29

Industrial Ventilation Any Questions? 30