ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw



Similar documents
ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

ABB micro inverters MICRO-0.25/0.3-I-OUTD, CDD and accessories 250 to 300 W

SolarMax P series The power package for residential solar plants

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

ABB central inverters PVS to 1000 kw

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

SUNNY TRIPOWER 5000TL 12000TL

SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY. Apparent Power Control (APC) unique micro inverter with

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

/ The allrounder with maximum yield. / WLAN interface / Smart Grid Ready

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

INVERTER SYSTEM PRODUCT BROCHURE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Solar Inverters Product Catalogue. Solar inverters, monitoring and support for residential / commercial installations and power plants

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SRS2025. Home & small Business. Energy Storage Solution

Three-phase monitoring relay CM-PFE

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

User s Manual Before using the inverter, you need to read and save the safety instructions.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Power Meter Series 700

Rack mounted telephone- and leased line modem for industrial applications

Photovoltaic Solar Energy Unit EESFB

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

for Energy Storage System, New & Renewable Energy

A project to optimise quality and energy efficiency must include metering

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

JSI Series Single Phase String Inverter. Features. Typical Efficiency Curve JSI-1500TL JSI-2000TL JSI-2500TL

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Telephone- and leased line modem for industrial applications TD-36

SYSTEM MONITORING Locally and remotely

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Quick Connect. quick - simple - efficient.

Sunny Family 2012 PRODUCT CATALOG

Electronic Control Devices The European Product Catalogue 2007

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Phase Modular Finally the benefits of Modular ups are for all

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Thyristor-controlled power supplies and battery chargers

SOLAR POWER CONDITIONER Service Manual

WVC300 Micro-inverter solar grid system (Power line communications)

Panorama Electricity meters For reliable values of energy consumption

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

vacon 8000 solar inverter a driving force in solar energy

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Remote Monitoring and REC 501 Control Unit Product Guide

HYBRID POWER SYSTEMS for TELECOM applications

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Thermistor motor protection

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

46120-F0 Solar Energy Training System

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

GROWATT NEW ENERGY CO.,LTD. GR - UM

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

HERZ-Thermal Actuators

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

YSmart Technology Co.,Ltd

Installation Guide Solar Connect-11

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

BB800 Off-Grid Solar System

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Energy Management Energy Meter Type EM23 DIN

Fronius IG Plus. The next generation grid-connected PV inverter

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

Application Note: String sizing Conext CL Series

SOLAR300N Rel /01/10

Huawei Solar Inverter Solution

Re-defining the utility-scale inverter

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

ADM1TE 5/30A DIN rail single phase two wire energy meter

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Inverter / Charger Installation General Operations and AC and DC Connections

is then retained absolutely without interruption.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

ACS-30-EU-EMDR-10-MOD

Actuator-Sensor-Interface

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

SURGE PROTECTIVE DEVICES

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

MOUNTING AND OPERATING INSTRUCTIONS

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

DS 600. A contact free flux gate based current measurement sensor 600A rms

Your own power station: For continuous power

Transcription:

Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges with solar energy is that it is unpredictable and its usage is not completely discretionary. The solution is to combine energy storage and load management capability with a traditional PV inverter. In this way self-consumption and energy self-sufficiency can be improved to a further level. *Self-consumption is how much PV energy is used at home and not exported to the grid with respect to the total energy production. Energy self-sufficiency is how much PV energy is used at home and not exported to the grid with respect to the total energy consumption. The advantages of a single, fully integrated device Coordination of all the energy flows with the goal of aligning PV energy production and home consumption Battery management and battery life are optimized One user interface, with remote capability, to monitor renewable energy production and manage home loads Highlights The REACT-4.6-TL (Renewable Energy Accumulator and Conversion Technology) is a PV single-phase grid connected inverter able to store energy in a 2.0kWh useful capacity Li-Ion battery integrated within the same product enclosure, expandable up to 3x All features found in our family of string inverters are maintained: double fast MPPT, broad input voltage range, top class efficiency with TL topology, compactness, installation flexibility Up to four onboard load management outputs are included as well as an auxiliary AC back-up output for off grid capability in case of a black out

REACT-3.6/4.6-TL Additional highlights The product is designed for a long life cycle with a 10 year expected battery life thanks to the Li-Ion technology Storage capacity can be further expanded up to three times adding further battery units Align production to consumption Technical data and types Solar and storage inverter system REACT-3.6-TL REACT-4.6-TL REACT-UNO-3.6-TL REACT-UNO-4.6-TL System components REACT-BAT-AP1 REACT-MTR-1PH (or -3PH) Solar and storage inverter REACT-UNO-3.6-TL REACT-UNO-4.6-TL Input side Absolute maximum DC input voltage (Vmax,abs) 600 V Start-up DC input voltage (Vstart) 200 V (adj. 120...350 V) Operating DC input voltage range (Vdcmin...Vdcmax) 0.7 x Vstart...580 V (min 90 V) Rated DC input voltage (Vdcr) 360 V Rated DC input power (Pdcr) 5000 W 6000 W Number of independent MPPT 2 Maximum DC input power for each MPPT (PMPPTmax) 2500 W 3000 W Linear derating [520V VMPPT 580V] Linear derating [520V VMPPT 580V] MPPT input DC voltage range (VMPPTmin... VMPPTmax) at Pacr, not operative battery 160 520 V 180 520 V Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax) 12 A / 24 A 13.5 A / 27 A Maximum input short circuit current for each MPPT 15.0 A Number of DC inputs pairs for each MPPT 2 DC connection type Tool Free PV connector WM / MC4 Input protection Reverse polarity protection Yes, from limited current source Input over voltage protection for each MPPT - varistor Yes Photovoltaic array isolation control According to local standard DC switch rating for each MPPT (version with DC switch) 25 A / 660 V Battery charger Maximum charging power 3000 W Maximum discharging power 3000 W Output side AC Grid connection type Single-phase Rated AC power (Pacr @cosφ=1 ) 3600 W 4600 W Maximum AC output power (Pacmax @cosφ=1) 3600 W 4600 W Maximum apparent power (Smax) 4000 VA 5100 VA Rated AC grid voltage (Vac,r) 230 V AC voltage range 180...264 V 1) Maximum AC output current (Iac,max) 19 A 24 A Rated output frequency (fr) 50 Hz / 60 Hz Output frequency range (fmin...fmax) 47...53 Hz / 57 63 Hz 2) Nominal power factor and adjustable range > 0.995, adj. ± 0.9 @ Pacr, ± 0.8 with max Smax Total current harmonic distortion < 2% AC connection type Screw terminal block, cable gland M25 Output protection Anti-islanding protection According to local standard Maximum external AC overcurrent protection 25 A 32 A Output overvoltage protection - varistor 2 (L - N / L - PE) ABB solar inverters Product flyer for REACT-3.6/4.6-TL

Daily energy flows example of REACT-4.6 8kWh 2.5kWh 10kWh 2kWh 2kWh Self-consumption 8+2 20 = ( ) = 50% Energy self-sufficiency = ( 8+2) = 80% 12.5 Technical data and types Solar and storage inverter REACT-UNO-3.6-TL REACT-UNO-4.6-TL Operating performance Maximum efficiency (ηmax) 97.1% Weighted efficiency (EURO/CEC) 96.6% / - Typical battery full cycle efficiency 94.0% Communication Remote monitoring Integrated Wireless local monitoring Integrated, WiFi certified User interface Mobile APP, Webserver UI, Graphic display Wired local monitoring PVI-USB-RS232_485 (opt.) Environmental Ambient temperature range -20...+55 C Optimal battery operational temperature range +5...+35 C Full battery function operational temperature range charge 0...+40 C Full battery function operational temperature range discharge -10...+45 C Relative humidity 0 95% non condensing Maximum operating altitude without derating 2000 m / 6560 ft Recommended location Indoor with ventilation openings Physical Environmental protection rating IP54 (inverter), IP21 (battery pack) Cooling Natural Dimension (H x W x D), equipped with 1 battery unit 740 mm x 983 mm x 229 mm Battery unit dimension (H x W x D) 740 mm x 490 mm x 229 mm Weight, equipped with 1 battery unit < 60 kg Battery unit weight < 30 kg Mounting system Wall bracket Safety Isolation level Transformerless Marking CE Safety and EMC standard EN 50178, IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN61000-3-11, EN61000-3-12, EN60529 Grid standard (check your sales channel for availability) CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, VFR2014 Other features Load management function Output for GOGO-box (opt.) AC back up output, off grid Optional, automatic or manual restart, even with battery discharged Battery charge from AC Services to grid enabled by factory, can be disabled No PV input version Optional special version, AC bus storage 1) The AC voltage range may vary depending on specific country grid standard 2) The Frequency range may vary depending on specific country grid standard Remark. Features not specifically listed in the present data sheet are not included in the product Product flyer for REACT-3.6/4.6-TL ABB solar inverters

Block diagram of REACT-4.6 Router + Modem Mobile App Wi-Fi network CLOUD Smartphone - Tablet - Desktop App. Database Aurora Vision Technical data and types Battery pack Manufacturer Battery type Typical/Max power discharge Max power charge Usable life average battery capacity Battery lifetime Battery calendar lifetime, typical Safety and EMC REACT-BAT-AP1 Panasonic Li-Ion 1.5 kw / 1.8 kw 1.1 kw 2 kwh (6 kwh, with 3x battery pack) > 4500 cycles 10 years ( Max 9 MWh discharged) EN62109-1, EN62109-2, EN50178, compliance to applicable requirements of EN60950-1, EN61000-6-2, EN61000-6-3, UN38.3, UN34.80 Meter REACT-MTR-1PH (or -3PH) AC line meter Necessary for optimum battery energy management Order separately REACT-MTR-1PH or REACT-MTR-3PH Measures P/ Q/ A/ V/ I Measures accuracy and resolution <1%, 1% Current capability 30 A, up to 5 Adc tolerant AC phases 1 or 3 Rated grid voltage / voltage range 110-230 V / 85...265 V Rated grid frequency / frequency range 50-60 Hz / 45...65 Hz Power supply and consumption Integrated, <1 W Isolation and dielectric strength 4kVrms (for 1 minute) between AC measuring ports and communication port Installation category CAT III, Protection class Front IP40, screw terminals IP20 Installation DIN 43880 Rail, 3 or 4 modules wide Operational temperature range -20...+55 C Safety and EMC IEC 61010-1, IEC 61326-1 Product flyer for REACT-3.6/4.6-TL ABB solar inverters

Block diagram of REACT-4.6 REACT-UNO IN1.1(+) IN1.2(+) IN1.1(-) MPPT 1 (DC/DC) Bulk caps Inverter (DC/AC) Switch L AC Backup Output N IN1.2(-) Line filter Grid parallel relay L AC Output N IN2.1(+) MPPT 2 (DC/DC) IN2.2(+) IN2.1(-) Residual current detection PE IN2.2(-) Control circuit RS485 + T/R - T/R RTN DC/DC DSP contr. µp DC/AC DSP contr. Remote control Alarm + R - R N.C N.O C Charger/ Discharger (DC/DC) Go Go Box RS485 RTU Modbus RS485 (Meter) Protection WIFI + T/R - T/R RTN + T/R - T/R RTN STOP REACT-BAT Battery pack Protection BMS Optional REACT-BAT Battery pack Protection BMS Product flyer for REACT-3.6/4.6-TL ABB solar inverters

Support and service ABB supports its customers with dedicated, global service organization in more than 60 countries and strong regional and national technical partner networks providing complete range of life cycle services. For more information please contact your local ABB representative or visit: www.abb.com/solarinverters www.abb.com/solar www.abb.com Copyright 2015 ABB. All rights reserved. Specifications subject to change without notice. BCD.00381 Rev. B EN 27.03.2015