VISIT US ON OUR WEBSITE @ WWW.PSI-PCI.COM



Similar documents
Engineering & Testing Services. Hydraulic Fitting Design and Hydro-Mechanical Testing

Herschel PACS Test Procedure STM PACS-KT-PR-011 Issue: 1 Revision: -

For Multi-Parameter Meters see mvx

SHOCK AND VIBRATION RESPONSE SPECTRA COURSE Unit 3. Sine Sweep Frequency and Octave Calculations

OPTIMASS 6000 Technical Datasheet

OPTIMASS 1400 Technical Datasheet

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

Flight Qualification of Omnisafe Anti-Torque, Multi Mate/Demate Fitting

BLADDER SURGE CONTROL SYSTEM

API Flanged Safety Relief Valves Series 526 CATALOG

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Compliant Terminal Technology Summary Test Report

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

Micro Motion Model D and DL Coriolis Flow and Density Meters

The number of parameters required for authoring an ipart depends on the type of the part you are publishing.

TRANSPORT OF DANGEROUS GOODS

Model DE-3 Air Release Head

Air Eliminators and Combination Air Eliminators Strainers

Baumann Flexsleev Sanitary Control Valve

TYPE CERTIFICATE DATA SHEET Nº EA-2011T03 Type Certificate Holder: COSTRUZIONI AERONAUTICHE TECNAM S.r.l. Via Tasso, Napoli Italy

Installing a Probe. Typical Installation

SMG. P/N _B NSF Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet. April Spanish French

Product and Package Testing Requirements for Transportation, Storage and Delivery

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

Physics 101 Hour Exam 3 December 1, 2014

SMA Interface Mating Dimensions (Per MIL-STD-348)

The Unique Accelabar Flow Meter

SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *

Address for Correspondence

The accelerometer designed and realized so far is intended for an. aerospace application. Detailed testing and analysis needs to be

VERTICAL TURBINE AND PROPELLER PUMPS

Review and History of PSI Elastomeric Diaphragm Tanks

AMP CO Plus Insert for Cat. 6 A Applications

Evaluation of Soft Soldering on Aluminium Nitride (AlN) ESTEC Contract No /05/NL/PA. CTB Hybrids WG ESTEC-22nd May 2007

Automotive Application Questionnaire for Electronic Control Units and Sensors. Electronic Components and Systems

MECHANICAL AND THERMAL ANALYSES OF THE CABLE/ STRAND STRAIN TEST FIXTURE

Nozzle Check Valves. NOREVA nozzle check valves are used

Lithium Ion Battery Specifications

A practical guide to restrictive flow orifices

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

SIMPLAIR PIPING TOOL

OLI. Oil level indicator

Rackmount Intelligent Pressure Scanners

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining

Vibration and Shock tests on a typical Current Transformer Set

APPENDIX F VIBRATION TESTING PROCEDURE

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

Fluid Mechanics: Static s Kinematics Dynamics Fluid

ETSI EN V2.1.2 ( )

167D Series Switching Valves

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

KNC Model 3666 Automatic Pressure Calibration System

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

4 Posiflow Proportional Solenoid Valves

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

Tool Holder Catalog INDEX ABC VDI 25 LL /Rö

LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO

Comparison of the Response of a Simple Structure to Single Axis and Multiple Axis Random Vibration Inputs

CCI HEAT PIPE DESIGN GUIDE

IRB 2600ID-15/1.85 Simple integration, high performance

I-PEX MHF4 Micro Coaxial Connector

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Vibration Test for Large Lithium-ion Battery Assemblies on UN Transportation Manual of Tests & Criteria JARI

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

HALT and HASS. Test Equipment For Highly Accelerated Life Test and Stress Screen Applications

DAKTON µ BOX MANUAL µbox User Manual 1

Automatic Self-Cleaning Strainers

TEST REPORT. Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Scientific & Technical Report

Green Thread Product Data

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

Portable Digitilt Tiltmeter

Osmosis. Evaluation copy

SELECTION, APPLICATION & MAINTENANCE

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

IFC 070 Technical Datasheet

SJT / SJM / SJP Large Vertical Pumps

Pipe Cutting and Beveling Clamshells

Mini slide, Series MSN narrow version Ø 6-16 mm double-acting with magnetic piston cushioning: elastic with integrated ball rail guide

CNG & Hydrogen Tank Safety, R&D, and Testing

Electromagnetic Flow Meter

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Operating instructions Platform/floor scales

Rusty Walker, Corporate Trainer Hill PHOENIX

Thermostatic valve Type AVTA

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Trace Dissolved Oxygen Sensor

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Liquid Level Limit Switch liquiphant T FTL 20

Pos. Qty. Article Description Price / Clamping surface x 430 mm Additional table load 1200 kg 3 T-slots 14 H12 for mounting on fixture, etc..

Transcription:

VISIT US ON OUR WEBSITE @ WWW.PSI-PCI.COM SIZE: 49.25'' in ID x 72.29'' in length Updated August 2011 SIZE: 1250.95 mm ID x 1836.17 mm length The tank assembly is a hemispherical pressure vessel of all welded construction. It is mounted by 32 circumferential tabs with nut plates located on one of the hemispheres near the girth weld joint. The tank contains an internally-mounted propellant management device (PMD), with perforated sheet and woven screen, fabricated to maintain speration of liquid propellant and gaseous pressurant, and to provide predictable gas-free liquid propellant expulsion from the tank under low or zero gravity conditions. The PMD has been designed to allow horizontal handling with low fill fractions. The PMD has also been modified by the addition of a slosh control device to allow multiple erection and de-erection cycles. The propellant and pressurant ports are 3/8 inch titanium-to-304 CRES transition tubes. Specification Requirements Imperial Units Ref. Temp. Metric Units Ref. Temp Reference / Note P/N 80517-1 Operating Pressure Proof Pressure Proof Cycle MEOP Cycle Design Burst Pressure Total Tank Volume Required Propellant Volume Maximum Mass Propellant Tube Diameter Pressurant Tube Diameter Frequency - lateral* Frequency - axial* 250.0 312.5 312.5 250.0 375.0 103,700 130 0.375 0.375 > 20 > 100 psid psid psid psid psid in3 in3 lb inch inch Hz Hz 92 F F F F F F F 17.2 21.5 21.5 17.2 25.9 1,700.0 59.09 9.525 9.525 bar bar bar bar bar liters liters kg mm mm 33.3 C C C C C C C 24 cycles 25 cycles minimum 20 to 96% fill fraction When immersed in propellant When immersed in propellant Loaded Tank Sine Vibration-Qualification/Protoflight (Wet) Frequency Acceleration (g,0-peak) 5-13 0.25 in. S.A. 13-17 5 Lateral (X or Y) 17-45 3 45-100 2 5.0-22.3 0.2 in. S.A Protoflight 22.3-24 10.2* 24-26 Ramp Down Axial(Z) 26-50 2.6 50-52 Ramp Down 52-100 1.3 Fluid: Loaded with 1670 kg of distilled water. Limit Acceleration(g) 5 5 3 3 10.2* 10.2* 10.2* 4.5 4.5 2.6 Loaded Tank Sine Vibration - Acceptance (Wet) Frequency Acceleration(g, 0 -Peak) 5-13 0.19 in. S.A 13-17 3.86 Lateral (X or Y) 17-45 2.31 45-100 1.54 5.0-22.3 0.13 in. S.A Acceptance 22.3-24 7.6* 24-26 Ramp Down Axial (Z) 26-30 2 50-52 Ramp Down 52-100 1 * Allowance made for 1g gravitational Limit Acceleration (g) 3.86 3.86 2.31 2.31 7.6* 7.6* 7.6* 3.46 3.46 2 Test Test Axis Axis

Unloaded Tank Sine Vibration - Qualification and Protoflight Frequency (Hz) Acceleration (g, 0-Peak) Test Axis 5.0-10.8 0.25 in. S.A 10.8-20 3 Qualification All (X,Y,Z) 20.0-100 1.5 100.0-400 1 Sweep Rate: 2 octaves/min Qualification 4 octaves/min Protoflight and Acceptance Loaded Tank Water: Random Vibration Level Frequency Protoflight and Qualification Acceptance (Reference only - - test not required) 90 to 100 100 to 800 800 to 2000 +30 db/oct +30 db/oct 0.054 g2/hz -3 db/oct 0.027 g2/hz -3 db/oct OVERALL (grms) 8.7 6.2 Loaded with 1670 kg of water and pressurized to MEOP 3.0 Minutes/Axis, Qualification Duration: 1.0 Minute/Axis, Acceptance and Protoflight

Interface Vibration test plot

ACCEPTANCE TESTS Examination of Product Weight Determination Pre-Proof Volume Determination Proof Pressure Test Post-Proof Volume Determination Expulsion Efficiency PMD Bubble Point Test External Leakage Test Penetrant Inspection Radiographic Inspection Final Examination of Product Cleanliness Verfication QUALIFICATION TESTS Examination of Product Weight Determination Pre-Proof Volume Determination Proof Pressure Test Post-Proof Volume Determination Proof Pressure Cycle Test MEOP Pressure Cycle Test Expulsion Efficiency Vibration Test PMD Bubble Point Test External Leakage Test Penetrant Inspection Radiographic Inspection Final Examination of Product Cleanliness Verfication Burst Pressure Test Reference Document Pass required lb maximum in3, record required psig, record required Actual Test Data: Serial No. XXX Pass/fail lb actual Acceptance Test not available as of 08/11/2011 3 in, record required %, record required Record required Propietary -6 Record required <1x10 std/cc Pass required Pass required Pass required Record required in3, record actual psig, record actual 3 in, record actual %, record actual Record actual Record actual Pass/fail Pass/fail Pass/fail Record actual Reference Document Actual Test Data: SN 0001Q Pass Pass/fail 130 111.52 lbs actual 103700 104192 in3, record actual in3, record required psig, record required 312.5 320 psig, record actual 104344 105188 in3, record actual in3, record required psig, record required 312.5 320 psig, 24 cycles psig, record required 250 252 psig, 100 cycles %, record required > 99.5 99 %, record actual See below for more details* Proprietary Record required PropietaryRecord actual std/cc He max 56-000264 1x10-6 3.6x10-8 std/cc He, record actual Pass required 56-000265 Pass Pass/fail Pass required 56-000266 Pass Pass/fail Pass required 56-000267 Pass Pass/fail Record required 56-000268 Pass Record actual psig, record required 56-000269 375 519 psig,record rupture Pass required lb maximum *Qualification Vibration Test Charts Natural Frequency Required min frequency ~ 47 Hz > 35 Hz X-Axis ~ 47 Hz > 35 Hz Y-Axis (lateral) ~ 61 Hz > 55 Hz Z-Axis (axial) Fluid: 3682 lb of Water or Nitrogen Gas @ 250 psig and ~ 64 deg. F *Qualification Sine Vibration Levels (Dry) Axis Y&Z Frequency (Hz) 5-10.8 10.8-20 20-100 100-400 Acceleration(G) (0-PEAK).25 inch SA 3.0 1.5 1.0 *Qualification Sine Vibration Levels (Wet) Axis Lateral (Y) Axial (Z) Frequency (Hz) 5-13 Acceleration (G) (0-Peak).25 inch SA 13-17 17-45 45-100 5-22.3 22.3-24 24-26 26-50 50-52 52-100 5.0 3.0 2.0.20 inch SA 10.2 Ramp Down 2.6 Ramp Down 1.3 *Qualification Random Vibration Levels Frequency(Hz) 90-100 100-800 800-2000 Overall G-rms Levels + 30 db/octave.054 G2/Hz -3dB/Octave 8.7 Prior to and after the full level random vibration test a 1/4 g sine survey shall be performed from 5 Hz to 2000 Hz at 4 octaves per minute with a 3 g limit in the lateral axis and a 4.5 g limit in the axial axis.

Burst Tank Pictures