EC type-examination certificate UK/0126/0099



Similar documents
EC Type-Approval Certificate UK 2943

Certificate of EC type-examination of a measuring instrument Number: UK/0126/0102

Certificate of EC type-approval of a measuring instrument Number: UK 2421 Revision 4

Supplementary Certificate of Approval NMI S669

How To Test For Totalizing Weight

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Experience with taximeters with a look at the corresponding tables

Repeaters and Mimics Data Sheet

Duct Humidity Transmitter

Industrial Balances PREMIUM Series 490 IBK/ITK/ISK

WELMEC 2.4 (Issue 2) WELMEC. European cooperation in legal metrology GUIDE FOR LOAD CELLS

NMI R 51 Automatic Catchweighing Instruments

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Product Information Sheet UH28CS-12kV Hi Pot Tester

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Multi-Range Programmable DC Power Supplies 9115 Series

IO-DIM6 6-Channel, Digital to Analogue Converters

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Temperature & Humidity SMS Alert Controller

Polyphase kwh Electricity Meter

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

NITP 6.1 to 6.4 National Instrument Test Procedures for Non-automatic Weighing Instruments

OIML R 76-1 RECOMMENDATION. Edition 2006 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Non-automatic weighing instruments

Using installed Fieldbus Wiring to carry Ethernet Communications

WELMEC European cooperation in legal metrology

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Programmable Controller G Series. New. Models

3500/22M Transient Data Interface

Telephone- and leased line modem for industrial applications TD-36

MechoNet TM Network Interface (MNI) Specification Submittal

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Current Monitoring Kit QUICK START GUIDE

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

EGSTON Standard E2xFxWx 12W

Certificate Pursuant to section 12 of the Weights and Measures Act 1985 Series V009 Revision 1

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Current Monitoring Kit

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

Multi-Range Programmable DC Power Supplies 9115 Series

SUPPLEMENT TO CERTIFICATE Series: 003 Revision 3

EC DECLARATION OF CONFORMITY FOR MACHINES

SNMP Web Management. User s Manual For SNMP Web Card/Box

Product Information Sheet UH36 Hi Pot Tester

INSTALLATION MANUAL XM3 Reader

3500/62 Process Variable Monitor

S-series DeviceNet Interface Card

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

Application/Connection Examples

Digital input modules

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

INSTRUCTION MANUAL VRT-200. TECSYSTEM S.r.l. Via Cristoforo Colombo, 5/C Corsico (MI) phone / Fax:

HCR3.2/.. Chipcard reader HOTEL SOLUTION

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MLC TM Maximum Productivity and Versatility for Control without Compromise!

User manual Rev 1.3 Contents

L5354 ControlNet Communications Interface

Voltage Regulator SPAU 341 C. Product Guide

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

IntesisBox KNX Mitsubishi Heavy Industries AC

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

WELMEC. European cooperation in legal metrology

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

OZW30. Central Unit SYNERGYR

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

Flow Monitoring System

Instruction Manual FL

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Rackmount Intelligent Pressure Scanners

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Rack mounted telephone- and leased line modem for industrial applications

UniOP epad33 and epad33t

QuickSpecs. Models HP Server Console Switches

Panel Meters and Controllers Modular Panel Meter Type EDM 35

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Installation manual. Generator Paralleling Controller GPC multi-line C

IRT Eurocard. Type DAX Audio Extractor for 270 Mb/s SDI

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

DVI KVM Switches DP-MUX 7.4

WIRELESS MAGNETIC CONTACT

The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.

3500/93 System Display

WELMEC European co-operation in legal metrology Guide for Examining Software (Non-automatic Weighing Instruments)

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

GSM Controller BR160GM-Gate

Electronic Control Devices The European Product Catalogue 2007

MI4 - Operator Panel : Engineering

WELMEC European Cooperation in Legal Metrology

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

KNX Panasonic Air Conditioners

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Transcription:

UK/0126/0099 MI-006 EC type-examination certificate UK/0126/0099 Issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments (Automatic Catchweighers) Regulations 2006 (SI 2006/1257) and the Measuring Instruments (Non-Prescribed Instruments) Regulations 2006 which implement, in the United Kingdom, Council Directive 2004/22/EC, this EC type-examination certificate has been issued to: Avery Weigh-Tronix Ltd Foundry Lane Smethwick West Midlands B66 2LP United Kingdom In respect of an automatic catchweighing instrument as described in the descriptive annex and having the following characteristics: Maximum capacity Dependant on application Minimum capacity Min 20 e Scale interval e 0.1 g Number of scale intervals n 10,000 Accuracy class Y(a) The necessary data (principal characteristics, alterations, securing, functioning etc) for identification purposes and conditions (when applicable) are set out in the descriptive annex to this certificate. Issue Date: Valid Until: Reference No: 09 June 2011 08 June 2021 TS0101/0004 Signatory: for P R Dixon Chief Executive National Measurement Office Stanton Avenue Teddington TW11 0JZ United Kingdom Tel +44 (0)20 8943 7272 Fax +44 (0)20 8943 7270 Web www.bis.gov.uk/nmo 0135 MID Annex B Rev. 2 01 April 2011

Descriptive Annex 1 INTRODUCTION This pattern of an automatic catchweighing instrument, comprising a controller designated the Avery Weigh-Tronix E1105/ E1110 / E1205 / E1210 Series, appropriate conveyors, pack detection and pack flow management devices, and a weighing unit comprising a load receptor and associated load cell(s), is designed to operate as an automatic weight labeller (Category Y). The instruments are designed to weigh packs statically. Sufficient time must be allowed for the static weight to be correctly taken for each application; a maximum conveyor speed must be determined, secured and checked at verification to ensure that the errors in automatic operation are less than the MPEs. Pack and labelling information is stored in files called PLUs selectable by the operator for the commodity or labels being processed. Labels are printed for the above transaction data and are applied to the packs automatically. Alternatively, the measurement data can be stored using the Data Storage Device. The data may be transmitted to a host computer for use in other applications, beyond the scope of this approval. 2 FUNCTIONAL DESCRIPTION 2.1 Mechanical 2.1.1 The instrument comprises a frame on which are mounted the modular conveyor sections (typically in-feed, weighing, out-feed). The conveyors type, number, size and shape are not restricted. 2.1.2 The instrument is designed to be permanently installed and fitted with a level indicator located on the weigh platform. 2.1.3 Weigh platform 2.1.3.1 The weighing device comprises a number of single strain gauge load cells fitted to the weigh platform. Any compatible load cell(s) may be used providing the following conditions are met: There is a respective OIML Certificate of Conformity (R60) or a test certificate (EN45501) issued for the load cell by a Notified Body responsible for type examination under Directive 2009/23/EC. The certificate contains the load cell types and the necessary load cell data required for the manufacturer s declaration of compatibility of modules (WELMEC 2, Issue 5, May 2009), and any particular installation requirements. A load cell marked NH is allowed only if humidity testing to EN45501 has been conducted on this load cell. The compatibility of the load cells and indicator is established by the manufacturer by means of the compatibility of modules calculation, contained in the above WELMEC 2 document, at the time of verification or declaration of EC conformity of type. The load cell transmission must conform to one of the examples shown in the WELMEC Guide 2.4, Guide for Load cells. 2/10

2.1.3.2 The instrument captures the weight when the stability of equilibrium has been reached. The zero-tracking device may be configured to be active when there are no packs on the platform. If a zero has not occurred within 375minutes, the conveyor stops and operation is inhibited until a zero occurs. Once a zero has been performed (semi-automatic zero-setting or zero tracking), weighing continues normally. 2.2 Electrical 2.2.1 The Avery Weigh-Tronix E1105/ E1110 / E1205 / E1210 Series (Figure 1) controller is as described in Evaluation Certificate GB-1395. It must be to Build Standard 5, as designated by 5 on the rating plate. 2.2.2 The system uses pack detection devices (e.g. photocells) and pack flow management devices (e.g. PLC) to determine where and when the packs have to be stopped on the weigh platform. The instrument also comprises a number of motors, drivers and relays to ensure correct pack flow. 2.3 Devices 2.3.1 The controller is provided with the following operational features (firmware): Semi-automatic zero-setting ( 4% max) Zero tracking ( 4% max, may be disabled) Automatic zero-setting (inhibits weighing if a zero has not occurred within 375minutes) Semi-automatic and pre-set tare devices (subtractive) Indication of stability of equilibrium Zero indicator Multi-interval option, with a maximum of 3 partial weighing ranges Totalisation Static calibration, not accessible to the user Data Storage Device, with a maximum of 65,000 data sets Digital and analogue outputs for controlling external devices Multi-scale option (additional internal A/D module card), with a maximum of 2 scales Automatic operation prevented during warm-up (2 min 15sec) 2.3.2 The following features or interlocks are provided: Preset Tare value can be displayed temporarily during automatic operation (by pressing the Status key) Semi-automatic zero setting not operable during automatic operation Tare and Preset Tare devices not operable during automatic operation Preset Tare values rounded to the nearest scale interval Printing below Min is not allowed Conveyor speed setting, not accessible to the user Totalised weight is clearly identified and is algebraic sums of printed/stored values When no labeller is in use, the recorded data (DSD) must include: date, time, pack weight, Tare or Preset tare if Net is recorded, instrument ID, pack ID (or batch ID when it is impractical to store individual batch IDs, provided the batch can be physically identified), units of measurement When no labeller is in use, the instrument must stop when the DSD is full, unless if at verification it can be shown that the DSD capacity and machine throughput ensure only records that are old enough will ever be deleted / 3/10

overwritten otherwise records cannot be overwritten unless they are older than x days, with x being a secured parameter to be determined at verification, manual deletion of data must be prevented unless records are older than x days. An approved external DSD may be connected to expand the storage capacity of the system, provided the above requirements are satisfied 3 TECHNICAL DATA 3.1 The instrument has the following technical characteristics: Power supply 110-240 Vac 50/60 Hz Maximum tare - Max Maximum number of scale intervals 10,000 Accuracy class Y(a) Load cell excitation voltage 10 VDC Minimum load cell impedance 22 Ω Maximum load cell impedance 1200 Ω Minimum input voltage per scale interval 0.6 µv Measuring range minimum voltage 6 mv Measuring range maximum voltage 20 mv Fraction of maximum permissible error Pind = 0.5 Operating temperature range -10 C to +40 C Climatic environment Closed, non-condensing EM Classification E1 and E2 Load cell cable (junction box to indicator) 6 core with braided outer screen. 0.5 mm2 per core, flexible PVC overall jacket Maximum length = 69 m (138 m/mm2). 3.2 Documentation and drawings Description OIML R51 manual Schematic diagram (Main board) Schematic diagram (ADC module) PCB assembly (Main board) E11xx PCB assembly (ADC module) Assembly drawing (E1110) Assembly drawing (E1105) Assembly drawing (E1205) Document No. NEU-087459 SCH25-000926 SCH25-000575 AWT25-000927 AWT25-000576 AWT05-053480 AWT05-800003 AWT05-800001 Assembly drawing (E1210) AWT05-800004 PSU (PS36-24-AV) Schematic diagram 5519 Dimensional drawing (plastic case E1105, E1205) 61226-366 (Front Cover) 61226-365 (Rear Housing) Dimensional drawing (metal case E1110, E1210) 61226-364 (Front Cover) 61226-363 (Enclosure) Service manual 76103-900 4/10

User manual (E1105 and E1110) 76103-899 User manual (E1205 and E1210) 76103-950 Expansion board 1 (analogue) PCB assembly Expansion board 1 (analogue) schematic diagram Expansion board 2 (digital) PCB assembly Expansion board 2 (digital) schematic diagram SRAM Expansion board PCB assembly SRAM Expansion board schematic diagram AWT25-000978 SCH25-000977 AWT25-001122 SCH25-001150 AWT25-001152 SCH25-001151 Anybus AB4306 Profibus DP board 70782-187 Anybus AB4136 DeviceNet board 70782-183 Anybus AB4007 ControlNet board 70782-184 Anybus AB4209 EthernetmodbusTCP board 70782-185 Anybus AB4307 EthernetIP board 70782-186 The functions to implement an automatic catchweighing instrument using the Avery Weigh- Tronix E1105 / E1110 / E1205 / E1210 Series are configured on an application-specific basis, and using a combination of Alarms, Trips and Setpoints, within the constraints of section 2.1.2 above and OIML R51-1:2006. A user manual specific to each application should be produced explaining the configuration and operation of the instrument to the end user. 4 PERIPHERAL DEVICES AND INTERFACES 4.1 Interfaces The instrument may have the following interfaces: Load cell 4 or 6-wire shielded connection (hardwired) 1 or 2 x RS232/RS485/20 ma (model dependant) 1 x serial O/P (to external O-I/P module) 10/100 Base T Ethernet Trip O/P (3) Control I/P (3) External PC style keyboard (IBM PS/2) Note: the load cell cable may be longer than 30 m, provided its length meets the requirement in table 3.1. 4.2 Optional interfaces and PCBs 4.2.1 The instrument may be fitted with any or all of the following optional boards: (i) load cell interface board (to allow the connection of a second platform, maximum of 16 load cells) and 2 analogue O/Ps (voltage or current), (ii) digital expansion board with two serial ports, which can be configured as either RS232 or RS485 or RS422, pulse input and BCD interface, (iii) SRAM expansion board, (iv) Anybus expansion board allowing any one of the following additional 5/10

fieldbus interfaces: a. Profibus DP b. DeviceNet c. ControlNet d. EthernetmodbusTCP e. EthernetIP 4.2.2 The indicator may additionally be configured to allow up to 16 remote I/O interfaces to be connected for driving relays, motors etc. and receive inputs from switches, photocells, etc. 4.3 Peripheral devices The instrument may be connected to any peripheral device that has been issued with a test certificate or parts certificate by a Notified Body responsible for Annex B (MI-006) under Directive 2004/22/EC in any Member State and bears the CE marking of conformity to the relevant directives; or A peripheral device without a test certificate may be connected under the following conditions: it bears the CE marking for conformity to the EMC Directive; it is not capable of transmitting any data or instruction into the weighing instrument, other than to release a printout, checking for correct data transmission or validation; it prints weighing results and other data as received from the weighing instrument without any modification or further processing; and it complies with the applicable requirements of Paragraph 8.1 of Annex I. 5 APPROVAL CONDITIONS The certificate is issued subject to the following conditions: 5.1 Legends and inscriptions 5.1.1 The instrument bears the following legends: CE marking Supplementary metrology marking Notified body identification number Accuracy class Serial number Manufacturers mark or name Certificate number Max Min e = T = Temperature-range Power supply Pneumatic pressure (if applicable) Maximum speed / pack rate 6/10

5.2 Software 5.2.1 The version numbers of the legally relevant software is either 768C App Basic for the E1105 / E1110 controller, or 769C App Advanced for the E1205 / E1210 controller. 5.2.2 The software of the pack flow management device (e.g. PLC) does not contain any legally relevant software. The software sends commands to the indicator in response to inputs such as pack detection, speed, weighing operation from the indicator. The software is application specific, the operation of which must be described in the application user manual required in section 3.2. 6 LOCATION OF SEALS AND VERIFICATION MARKS 6.1 The CE marking, supplementary metrology marking and certificate number are located on the instrument, and must be clearly visible. The CE mark shall be impossible to remove without damaging it. The data plate shall be impossible to remove without it being destroyed. The markings and inscriptions shall fulfil the requirements of Paragraph 9 of Annex I of the Directive 2004/22/EC. 6.2 Access to the configuration and calibration facility is password protected. The indicator increments a configuration and/or calibration value (designated as config Event and Calibration Event respectively) each time the indicator is re-configured and/or calibrated. The value(s) are recorded on a tamper evident label on or near the rating plate. The current value can be displayed by selecting either:- Super (F2) Alter (F3) (F3) x 3 Audit (F1) View (F2), for the E1105 / E1110 controller, or Super (F2) Alter (F3) (F5) x 3 Audit (F1) View (F2), for the E1205 / E1210 controller. The dot matrix display then shows: Audit Trail Calibration Events xx Config Events xx. Pressing Escape (ESC) - Exit (F1) - Exit (F1) returns the indicator to normal operating mode. 6.3 Alternatively, physical sealing may be used to protect the calibration and legally relevant parameters. Calibration and configuration modes can be entered via a push button located on the main PCB which is accessed by removing the front cover of the sealed enclosure 6.4 Components that may not be dismantled or adjusted by the user (load cell, calibration mode) will be secured by either a wire and seal or tamper evident label and securing mark. The securing mark may be either: a mark of the manufacturer and/or manufacturer s representative, or an official mark of a verification officer. 7/10

7 ALTERNATIVES There are currently no alternatives. 8 ILLUSTRATIONS Figure 1 Figure 2 Figure 3 E1105 and E1110 controllers E1205 controller Rating plate 9 CERTIFICATE HISTORY ISSUE NO. DATE DESCRIPTION UK/0126/0099 09 June 2011 Type examination certificate first issued. 8/10

Figure 1 E1105 and E1110 controllers Figure 2 E1205 controller 9/10

Figure 3 Rating plate Crown Copyright 2011 NATIONAL MEASUREMENT OFFICE Department for Business, Innovation & Skills 10/10