Analytical Testing Services Commercial Price List ManTech International Corporation January 2016



Similar documents
Thermal cover:layout 1 1/18/11 3:56 PM Page 2 TA Instruments

CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager

Department of Engineering Enzo Ferrari University of Modena and Reggio Emilia

Thermal diffusivity and conductivity - an introduction to theory and practice

Characterization of Electronic Materials Using Thermal Analysis

Rapid Cure of Polyimide Coatings for Packaging Applications using Variable Frequency Microwave Irradiation

4 Thermomechanical Analysis (TMA)

Client: RENOLIT Italia Srl. Work completion: 01/10/2008 (or after receipt of the weathered samples) Notes: Preliminary Report

Lecture 9, Thermal Notes, 3.054

Thermal Analysis Excellence

Table of content. L81/RITA high speed Thermo Balance. Quattro Dilatometer. L75/1250/B/S Macro Dilatometer. New air cooled furnace program

Back to Basics Fundamentals of Polymer Analysis

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

Infrared Optical Fiber. Datasheets and Price list. JTIngram Sales and Marketing

What is Solar Control?

IUCLID 5 COMPOSITION AND ANALYSIS GUIDANCE DOCUMENT: IRON ORES, AGGLOMERATES [EINECS NUMBER , CAS NUMBER ] IRON ORE PELLETS

Tech Bulletin. Understanding Solar Performance

Determination of the heat storage capacity of PCM and PCM objects as a function of temperature

Raman spectroscopy Lecture

CVD SILICON CARBIDE. CVD SILICON CARBIDE s attributes include:

Solar heat reflective paint & coatings using 3M Glass Bubbles

TA INSTRUMENTS DYNAMIC MECHANICAL ANALYZER

Zero Width Glass Cutting with CO 2 Laser

Effects of Tg and CTE on Semiconductor Encapsulants

Amodel AS-1133 HS. polyphthalamide. Technical Data Sheet

Spectral Measurement Solutions for Industry and Research

Master of Simulation Techniques. Lecture No.5. Blanking. Blanking. Fine

TIE-31: Mechanical and thermal properties of optical glass

The CVD diamond booklet

Corning HPFS 7979, 7980, 8655 Fused Silica. Optical Materials Product Information Specialty Materials Division

Characterization of Polymers Using TGA

3 Nextel Textiles. Ceramic fiber products for outerspace applications.

Ultra-high Barrier Plastic. MSE5420 Flexible Electronics Martin Yan, GE Global Research

Reflectance Characteristics of Accuflect Light Reflecting Ceramic

XFA 600 Thermal Diffusivity Thermal Conductivity

DETECTION OF COATINGS ON PAPER USING INFRA RED SPECTROSCOPY

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETER (DSC) Insert Nickname Here. Operating Instructions

R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Chapter 6 Metal Films and Filters

WOOD WEAR TESTING USING TRIBOMETER

CERAMIC XENON LAMPS APPLICATIONS FEATURES & BENEFITS VAC CERAMIC XENON LAMPS

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied

DIODE PUMPED CRYSTALASER

nanovea.com MECHANICAL TESTERS Indentation Scratch Wear

PIEZOELECTRIC FILMS TECHNICAL INFORMATION

Components for Infrared Spectroscopy. Dispersive IR Spectroscopy

Coating Thickness and Composition Analysis by Micro-EDXRF

HFM Heat Flow Meter Thermal Conductivity Analyzer

THE IMPACT OF YIELD STRENGTH OF THE INTERCONNECTOR ON THE INTERNAL STRESS OF THE SOLAR CELL WITHIN A MODULE

Moldflow Material Testing Report MAT2215 ISOGLASS H 30 FVL C NAT

Micro-Power Generation

Experiment 5. Lasers and laser mode structure

Preface Light Microscopy X-ray Diffraction Methods

OPTICAL DETECTION OF KCl VAPOR AND ATOMIC K RELEASES FROM BIOMASS FUELS COMBUSTED IN SINGLE PARTICLE REACTOR

Innovative value chain development for sustainable plastics in Central Europe

DuPont Kapton HN. polyimide film

Power distribution systems

3M Thermal Bonding Film AF42

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Optical Communications

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

The Three Heat Transfer Modes in Reflow Soldering

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

Fiber Optic Specifications

XII. 3.2 Determining Bulk Material Properties Determining the Properties of Fluids 42

Solution for Homework #1

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

Detection of Exposure Damage in Composite Materials Using Fourier Transform Infrared Technology

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

High power picosecond lasers enable higher efficiency solar cells.

Iterative calculation of the heat transfer coefficient

Preliminary Comments

Expansion and shrinkage of fibers

Lecture 14. Chapter 8-1

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

Group A/B Dust Explosion Classification Chilworth Hazard and Risk Profile (CHARP) - Standard package of tests

joining expertise at the service of the plastic converting industry

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

CERTIFICACIONES Y PRUEBAS DE LABORATORIO

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

ADHESIVE BONDING PERFORMANCE OF GA COATED 590 MPa TENSILE STRENGTH STEELS

Agilent Cary 60 UV-Vis

Bridging the analytical gap

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation

INFRARED PARTS MANUAL

Temperature. LumaSense Technologies, Inc. supplies a unique selection of very precise calibration

A Beginner s Guide DMA

Applications. Blue IF 039, Green IF 062, Yellow IF 022, Orange IF 041, Red IF 090,Dark Red IF 091 IR pass IF 092, IF098, IF 093 Surface 1 5/2 0.

Nanoscale Resolution Options for Optical Localization Techniques. C. Boit TU Berlin Chair of Semiconductor Devices

THERMAL RADIATION (THERM)

DSC Differential Scanning Calorimeter

Espotel Test Laboratory Services. November 20, 2014

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Silicone Rubber Thermal Interface Materials: Applications and Performance Considerations

Material data sheet. EOS CobaltChrome MP1. Description

Optical Fiber Switches

Transcription:

Analytical ing Services Commercial List ManTech International Corporation January 2016

TABLE OF CONTENTS MECHANICAL TENSILE TESTING... 1 DIFFERENTIAL SCANNING CALORIMETRY (DSC)... 2 THERMOMECHANICAL ANALYSIS (TMA)... 3 DYNAMIC MECHANICAL ANALYSIS (DMA)... 4 UV/VIS/NIR SPECTROPHOTOMETRY... 5 FOURIER TRANSORM INFRARED SPECTROSCOPY (FTIR)... 6 EMISSIVITY... 7 ELECTRICAL RESISTIVITY... 8 SURFACE PROFILOMETRY... 9 CONSULTING... 10 VOLUME TESTING DISCOUNTS... 11 CONTACT INFORMATION... 11 Note: pricing includes an analytical report in electronic format containing all test data.

Tensile Mechanical Tensile ing Tensile Strength; Elongation at Break; Elastic Modulus; Yield Strength; Peel Strength, Seal Strength Instron Model 5569: Two Column Table Mounted Universal Materials ing System with Environmental Chamber Supporting 120 C to +300 C. Room Temperature Below Room Temperature Above Room Temperature ASTM D638 10, D882 02, D3528 96, D1002 05, D1938 08; F88/F88M 15; D903 98 ASTM D638 10, D882 02, D3528 96, D1002 05, D1938 08; F88/F88M 15; D903 98 ASTM D638 10, D882 02, D3528 96, D1002 05, D1938 08; F88/F88M 15; D903 98 ASTM D638 10, D882 02, D3528 96, D1002 05, D1938 08; F88/F88M 15; D903 98 ASTM D638 10, D882 02, D3528 96, D1002 05, D1938 08; F88/F88M 15; D903 98 if testing conducted at RT if testing conducted below RT if testing conducted above RT Ambient temperature (~23 C) Above Room Temperature (24 C to 150 C) Above Room Temperature (151 C to 300 C) Below Room Temperature ( 60 C to 22 C) Below Room Temperature ( 120 C to 60 C) 1 $250 1 $450 1 $350 Up to 5 $250 Up to 5 $300 Up to 5 $400 Up to 5 $525 Up to 5 $625 Page 1 of 11

DSC Scan Differential Scanning Calorimetry (DSC) Glass Transition Temperature (T g ); Melting Temperature (T m ); Crystallization Temperature (T c ) TA Instruments Model Q200 Modulated Differential Scanning Calorimeter (DSC) with 50 C to +725 C temperature capability; mass flow control; RCS90 refrigerated cooling system; gas dryer. ASTM D7426 08; D3418 08; E1356 08 ASTM D7426 08; D3418 08; E1356 08 ASTM D7426 08; D3418 08; E1356 08 Duplicate Scan Up to 100 C 10 C/min or Higher Rate Duplicate Scan Up to 300 C 10 C/min or Higher Rate Duplicate Scan Up to 500 C 10 C/min or Higher Rate 1 $300 1 $300 1 $360 1 $420 Page 2 of 11

Thermomechanical Analysis (TMA) TMA Scan Coefficient of Thermal Expansion (CTE); Glass Transition Temperature (T g ); Creep; Modulus, Tan Delta TA Instruments Q400EM Thermomechanical Analyzer (TMA) with Mass Flow Control; Modes of operation include temperature ramp, isostrain, force ramp, stress ramp, strain ramp, isostrain, creep, stress relaxation, dynamic TMA, and modulated TMA; Temperature Range is 150 C to +1000 C; automated furnace and probe movement, automated sample dimension measurement, and automated air cooling; Quartz sample stage; Available probes include standard expansion probe, penetration probe, macro expansion probe; Film and fiber accessory kit; 3 point bend probe. ASTM E831 06 ASTM E831 06 ASTM E831 06 Case Specific Creep Case Specific Creep Case Specific Creep Duplicate Scan Up to 100 C 10 C/min or Higher Rate Duplicate Scan Up to 300 C 10 C/min or Higher Rate Duplicate Scan Up to 500 C 10 C/min or Higher Rate Initial Creep Setup Minimum Temp 40 C range Initial 24 hour test Single Scan Minimum Temp 40 C range Each additional 24 hour Single Scan Minimum Temp 40 C range 1 $300 1 $300 1 $360 1 $420 1 $1,250 1 $1,250 1 $600 Page 3 of 11

Dynamic Mechanical Analysis (DMA) DMA Scan Storage Modulus (E'); Loss Modulus (E''); Tan Delta; Glass Transition Temperature (T g ) Rheometrics DMTA Mark V Dynamic Mechanical Thermal Analyzer (DMA); Modes of operation include single cantilever, dual cantilever, three point bend, shear, or extension modes; Temperature sweep range is 75 C to +500 C; frequency sweep or stress sweeps are also available 1 $325 Case Specific Call 1 Call Page 4 of 11

UV/Vis/NIR Spectrophotometry UV/Vis/NIR Scan Ultraviolet (UV), Visible, and Near Infrared (NIR) Transmission, Reflection, Absorption Perkin Elmer Model Lamda 950 Spectrophotomer with spectral range 175 3300 nm complete with spectralon coated integrating sphere (250 2500 nm) for true reflectance and transmission measurements. 1 $250 Film Scan Trans. or Refl. 500 nm Range Film Scan Trans. or Refl. Full 250 2500 nm Range 1 $250 1 $360 Liquid Scan Trans. Only 500 nm Range 1 $250 Liquid Scan Trans. Only Full 175 3300 nm Range Data Analysis, Reduction for Solar Optical Values (τ s, ρ s, α s ) for AM0 or AM1.5 1 $360 1 $150 Page 5 of 11

Fourier Transform Infrared Spectroscopy (FTIR) FTIR Scan Infrared Transmission, Reflection, Absorption Bruker Model Tensor 27 Fourier Transform Infrared Spectrometer with Spectral range 1 25 µm, complete with gold coated integrating sphere for true reflectance and transmission measurements. Film Scan Trans.or Refl. Liquid Scan Transmission Only Solid Pellet Scan Transmission Only 1 $350 1 $350 1 $350 1 $450 Page 6 of 11

Infrared Emissivity Emissivity Scan Hemispherical or Normal Infrared Emittance / Infrared Emissivity ASTM E408 71 AZ Technology Temp 2000A Emissometer/reflectometer measures total hemispherical reflectance, <3 to >35 micrometers wavelength. Provides both normal and hemispherical 300k (ambient) emittance measurements. The recognized replacement for the no longer produced Gier Dunkle DB 100 IR Reflectometer, with improved performance and maintainability and in accordance with the ASTM E408 standard. IR Emittance Hemispherical or Normal 1 $250 Up to 5 $150 Page 7 of 11

Electrical Resistivity Resistivity Measurement Surface or Bulk Electrical Resistivity ASTM D257 07 ASTM D257 07 Prostat PRS 812 resistance meter coupled with Prostat PRF 911 concentric ring fixture or PRF 912B miniature concentric ring fixture Surface Resistivity 10 1 10 12 ohms/sq range Volume Resistivity 10 1 10 12 ohms range 1 $200 Up to 3 $175 Up to 3 $175 Page 8 of 11

Surface Profilometry Surface Profilometry Step Height 3 D Surface Profile Bruker Dektak 150 Surface Profiler with automated sample stage. 150 x 150 mm X Y scan capabiltiy with sample thicknesses up to 1 mm. 2 D Step Height Measurement 1 $350 1 $250 3 D Surface Mapping 1 $1,500 Page 9 of 11

Consulting Additional Consulting General Consulting Consulting Services with Ph.D. Analytical Laboratory Manager Time N/A Consulting Per Hr 1 hr $200 Page 10 of 11

Volume ing Discounts Pricing discounts are available for multiple samples, please inquire for more information. Contact Information For any questions or for additional information, please contact: Analytical Laboratory Manager D. Lynn Rodman, Ph.D. Phone 256 971 7043 Email lynn.rodman@nexolve.com Address 655 Discovery Drive Huntsville, AL 35806 Page 11 of 11