OPLC Installation Guide

Similar documents
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Screen 3.5" Color Touch 4.3" Color Touch Keypad or Function Keys Programming Com Port, Built-in

UniStream CPU-for-Panel

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

V350-R34 V350J-R34. npn inputs pnp inputs

V350-TA24 V350J-TA24.

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Using Remote Operator 2/2010

MCR1900 Media Converter 19-Slot Chassis

=============================== WARNING

Universal Vehicle Power Supply 9007AX01. Installation Instructions

AXIS 291 1U Video Server Rack Installation Guide

Sunny Boy Accessories SMA POWER BALANCER

DLP-PU/E Instruction Manual

Radiant Temperature Sensor TY7321

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

3M Wrist Strap and Footwear Tester 740. User s Guide

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Manual. Solar Fountain Mobile Phone Charger

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Advantium 2 Plus Alarm

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Architect/Contractor Information Package

Single Station Remote Alarm

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

HM-W536 Install Guide

Model 201 Wiegand Touchpad Reader Installation Guide

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Achat 115MA full-range speaker. user manual

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

NFC Communication Tray Model: HHX-IT3-Z

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

5800 Temperature Sensor Cable Assembly

Single Phase Soft Starter

MIC-WKT and MIC-WKT-IR

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Troubleshooting and Diagnostics

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Modular I/O System Analog and Digital Interface Modules

StorTrends 3400 Hardware Guide for Onsite Support

About the BitStorm 6051 POTS Splitter

BroadBand PowerShield. User Manual

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

LIEBERT VNSA Installation Sheet

Battery Power Inverters

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Application/Connection Examples

HMI display Installation Guide

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

M3 ORANGE Snap-On. User Guide. Product Model: A-SNO-ATYP-060-R00. Compatible Device: M3 ORANGE. Version 2.2 Released in March 2013

AMPSEAL* Automotive Plug Connector and Header Assembly

Power supply unit Model: PAC-SC50KUA

Serial ATA Hard Drive Enclosure

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

AXIS T81B22 DC 30W Midspan

HP UPS R1500 Generation 3

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

SMART Board 8055i and 8055i-SMP

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

12 Volt 30 Amp Digital Solar Charge Controller

PCI Express USB 2.0 Adapter Card

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

U-shaped Micro Photoelectric Sensor

How To Use A Sata Dsa Hard Disk Storage System

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Mounting Instructions for SP4 Power Modules

12-Volt 10-Amp Regulated Power Supply

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

WIRELESS STATUS MONITOR

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

Cross-beam scanning system to detect slim objects. 100 mm in

ADM1TE 5/30A DIN rail single phase two wire energy meter

MultiVOIP FX SIP Gateways

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Manual Ranging MultiMeter

CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual

Electronic overload relay EF65, EF96 and EF146

Digi-Motor Installation Guide

Moxa EtherDevice Switch

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Electronic overload relay EF19 and EF45

Installation Manual. BYD Wall-mounted AC Charging Box

SMART Board 8070i-SMP and 8070i

Transcription:

Samba OPLC SM43-J-T20/ SM35-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs are set to pnp), 8 Relay Outputs 12 Digital Inputs, include 3 HSC/Shaft-encoder Input, 2 Analog inputs, 8 Transistor Outputs General Description The SAMBA SM43-J-R20/SM43-J-T20 OPLC is an All-in-One Programmable Logic Controller that Comprises a built-in 4.3" Color Touchscreen. The SAMBA SM35-J-R20/SM35-J-T20 OPLC is an All-in-One Programmable Logic Controller that Comprises a built-in 3.5" Color Touchscreen. Communications For SM43: USB device programming port (Mini-B) For SM35: 1 build-in serial port:rs232 Optional: the user may install - RS232/RS485 port (V100-17-RS4/V100-17-RS4X) or Ethernet (V100-17-ET2) & CANbus (V100-17-CAN) Standard Kit Contents Samba controller I/O connectors (x2) Battery (installed) Alert Symbols and General Restrictions Mounting brackets (x2) Rubber seal When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Danger Warning Caution Caution Use caution. The identified danger causes physical and property damage. The identified danger could cause physical and property damage. Before using this product, the user must read and understand this document. All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product according to local and national standards and regulations. Only qualified service personnel should open this device or carry out repairs. Failure to comply with appropriate safety guidelines can cause severe injury or property damage. Do not attempt to use this device with parameters that exceed permissible levels. To avoid damaging the system, do not connect/disconnect the device when power is on. Environmental Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration, in accordance with the standards given in the product s technical specification sheet. Do not place in water or let water leak onto the unit. Do not allow debris to fall inside the unit during installation. Ventilation: 10mm space required between controller s top/bottom edges & enclosure walls. Install at maximum distance from high-voltage cables and power equipment. Unitronics 1

Samba OPLC Installation Guide Mounting Dimensions SM43-J-R20/SM43-J-T20 SM35-J-R20/SM35-J-T20 2 Unitronics

Samba OPLC Panel Mounting SM43-J-R20/SM43-J-T20 Before you begin, note that the mounting panel cannot be more than 5 mm thick. 1. Make a panel cut-out measuring 122.5x91.5 mm (4.82 x3.6 ). 2. Slide the controller into the cutout, ensuring that the rubber seal is in place. 3. Push the mounting brackets into their slots on the sides of the panel as shown in the figure to the right. 4. Tighten the bracket s screws against the panel. Hold the bracket securely against the unit while tightening the screw. 5. When properly mounted, the controller is squarely situated in the panel cut-out as shown in the figure to the right. Note: For UL listed module, in order to meet the UL508 standard, panel-mount this device on the flat surface of a Type 1 enclosure. Unitronics 3

Samba OPLC Installation Guide Panel Mounting SM35-J-R20/SM35-J-T20 Before you begin, note that the mounting panel cannot be more than 5 mm thick. 1. Make a panel cut-out measuring 92x92 mm (3.622 x3.622 ). 2. Slide the controller into the cutout, ensuring that the rubber seal is in place. 3. Push the mounting brackets into their slots on the sides of the panel as shown in the figure to the right. 4. Tighten the bracket s screws against the panel. Hold the bracket securely against the unit while tightening the screw. 5. When properly mounted, the controller is squarely situated in the panel cut-out as shown in the figure to the right. Note: For UL listed module, in order to meet the UL508 standard, panel-mount this device on the flat surface of a Type 1 enclosure. Wiring Do not touch live wires. Caution Install an external circuit breaker. Guard against short-circuiting in external wiring. Use appropriate circuit protection devices. Unused pins should not be connected. Ignoring this directive may damage the device. Double-check all wiring before turning on the power supply. To avoid damaging the wire, do not exceed a maximum torque of 0.5 N m (5 kgf cm). Do not use tin, solder, or any substance on stripped wire that might cause the wire strand to break. Install at maximum distance from high-voltage cables and power equipment. 4 Unitronics

Samba OPLC Wiring Procedure Use crimp terminals for wiring; use 3.31 mm ² 0.13 mm² wire (12-16 AWG): 1. Strip the wire to a length of 7±0.5mm (0.270 0.300 ). 2. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure a proper connection. 4. Tighten enough to keep the wire from pulling free. Input or output cables should not be run through the same multi-core cable or share the same wire. Allow for voltage drop and noise interference with I/O lines used over an extended distance. Use wire that is properly sized for the load. The controller and I/O signals must be connected to the same 0V signal. I/Os comprises a total of 12 inputs and 8 relays. Input functionality can be adapted as follows: 1. 12 inputs may be used as digital inputs. They may be wired in a group via a single jumper as either npn or pnp. According to jumper settings and appropriate wiring: - Inputs 5 and 6 can function as either digital or analog inputs. If the digital inputs function as npn, analog option is not available. - Input 0 can function as a high-speed counter, as part of a shaft-encoder, or as a normal digital input. - Input 1 can function as either a counter reset, normal digital input, or as part of a shaft-encoder. - If input 0 is set as a high-speed counter (without reset), input 1 can function as a normal digital input. SM43-J-T20/SM35-J-T20 comprises a total of 12 inputs and 8 transistor outputs. Input functionality can be adapted as follows: 1.12 inputs may be used as digital inputs. They may be wired in a group via a single jumper as either npn or pnp. According to jumper settings and appropriate wiring: - Inputs 10 and 11 can function as either digital or analog inputs. - Inputs 0, 2, and 4 can function as high-speed counters, as part of a shaft-encoder, or as normal digital inputs. - Inputs 1, 3, and 5 can function as either counter reset, as part of a shaft-encoder, or as normal digital inputs. - If inputs 0, 2, 4 are set as high-speed counters (without reset), inputs 1, 3, 5 can function as normal digital inputs. Unitronics 5

Samba OPLC Installation Guide Input and Output Jumper Settings The tables below show how to set a specific jumper to change input functionality. To access the I/O jumpers, you must open the controller according to the instructions below. Incompatible jumper settings and wiring connections may seriously damage the controller. Digital Inputs 0-11: Set Type Set to JP12 (all Inputs) npn (sink) A pnp (source)* B Input 5: Set Type - Digital or Analog #1 Set to JP4 JP10 Digital* A A Voltage B A Current B B Input 6: Set Type - Digital or Analog #0 Set to JP8 JP9 Digital* A A Voltage B A Current B B *Default settings SM43-J-T20/SM35-J-T20 Do not move JP2. Digital Inputs 0-11: Set Type Set to npn (sink) pnp(source)* JP1 (all Inputs) A B Inputs 10/11: Set as Digital or Analog Set to JP5 (Input 10) JP6 (Input 11) Digital* A A Analog B B Analog Inputs AN0/AN1: Set Type Set to JP3 (AN0) JP4 (AN1) Voltage* A A Current B B *Default settings 6 Unitronics

Samba OPLC Opening the Controller Note: Photo is for illustration purposes only. (Using SM43) Before performing these actions, touch a grounded object to discharge any electrostatic charge. Avoid touching the PCB board directly. Hold the PCB board by its connectors. 1.Turn off the power supply, disconnects, and dismounts the controller. 2.The back cover of the controller comprises 4 screws, located in the corners. Remove the screws, and pull off the back cover. Changing I/O Settings 1.The I/O board of the controller is now exposed, enabling you to change I/O settings according to the jumpers above. Closing the Controller 1.Replace the back cover of the controller and fasten the corner screws. Note that you must replace the back cover securely before powering up the controller. I/O Wiring npn Input Wiring Input wiring, npn (sink) SM43-J-T20/SM35-J-T20 Unitronics 7

Samba OPLC Installation Guide HSC input wiring, npn (sink) pnp Input Wiring Input wiring, pnp (source) SM43-J-T20/SM35-J-T20 HSC input wiring, pnp (source) 8 Unitronics

Samba OPLC Shaft-encoder SM43-J-T20/SM35-J-T20 Analog Input Wiring SM43-J-T20/SM35-J-T20 Analog input wiring, current (2/3 wire) Analog input wiring, current/voltage (4-wire) Shields should be connected at the signal s source. The 0V signal of the analog input must be connected to the controller s 0V. Unitronics 9

Samba OPLC Installation Guide Relay Outputs Transistor Outputs SM43-J-T20/SM35-J-T20 Increasing Contact Life Span - Only To increase the life span of the relay output contacts and protect the device from potential damage by reverse EMF, connect: A clamping diode in parallel with each inductive DC load An RC snubber circuit in parallel with each inductive AC load Power Supply The controller requires an external 24VDC power supply. Note: Photo is for illustration purposes only. 1. The power supply must include double insulation. Outputs must be rated as SELV/PELV/Class 2/Limited Power. 2. Use separate wires to connect the functional earth line (pin 3) and the 0V line (pin 2) to the system earth ground. 3. Install an external circuit breaker. Guard against short-circuiting in external wiring. 4. Double-check all wiring before turning on the power supply. 5. Do not connect either the Neutral or Line signal of the 110/220VAC to device s 0V pin. 6. In the event of voltage fluctuations or nonconformity to voltage power supply specifications, connect the device to a regulated power supply. 10 Unitronics

Samba OPLC Earthing the OPLC To maximize system performance, avoid electromagnetic interference by: Mounting the controller on a metal panel. Connect each common and ground connection directly to the earth ground of your system. For ground wiring use the shortest and thickest possible wire. Communication Port Turn off power before making communications connections. Caution Always use the appropriate port adapters. SM43-J-R20/SM43-J-T20 This series comprises a USB port. Caution The USB port is not isolated. Make sure that the PC and the controller are grounded to same potential. The USB port may be used for programming, OS download, and PC access. SM35-J-R20/SM35-J-T20 This series comprises a build-in RS232 port. Caution Signals are related to the controller s 0V; the same 0V is used by the power supply. The serial port is not isolated. If the controller is used with a non-isolated external device, avoid potential voltage that exceeds ± 10V. Use RS232 to download programs from a PC, and to communicate with serial devices and applications, such as SCADA. Pinouts The pinouts below show the PLC port signals. RS232 Pin # Description 1 Not connected 2 0V reference 3 TXD signal 4 RXD signal 5 0V reference 6 Not connected Unitronics 11

Samba OPLC Installation Guide The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the forgoing from the market. All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising out of or in connection with the use or performance of this information. The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them DOC17009-C8 11/14 12 Unitronics