EFFECTA RECOMMENDATIONS FOR WOOD FRAMED PELLET STORAGES

Similar documents
2.9 WINDOW & DOOR BUCKS

HORIZONTAL INSTALLATION

39HQ Airovision Air Handling Units

Best Barns USA Assembly Book

Laser Calibration Check

Guidelines for designing a wood pellet storage facility

RESERVDELSLISTA NORMFINISH DP14

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Contrast 2 LED. Performance Compactness Complete flexibility NEW

YFS Automotive Systems, Inc. Supplier Packaging Guidelines

FM 4473 TEST REPORT. Rendered to: VTECH INDUSTRIES, LLP. SERIES/MODEL: 4 x 4 CMC Hurricane PRODUCT TYPE: Skylight

FLAT ROOF BOX SPAN CARPORTS

Installation Manuals Version n. 01 of 14/06/2013

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

FAST EnergyCam supported meters

Installation Guide. Bath and Wall Surrounds SERIES B

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

Module 5 (Lectures 17 to 19) MAT FOUNDATIONS

9.3 Two-way Slabs (Part I)

Approved Document Q: Security

Owner's Manual & Assembly Instructions

Instruction Manual 19/9/01. Flat Roof Carport

Structural fire design Eurocode Timber structures

Replacing N-300 PCB YZ Systems for use by YZ s distribution network and end-users.

basic module technical specifications infinity modular case

Plaisance 50. Windows and doors. Sapa Building System


Formwork for Concrete

FLAT ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

Avantis 75. Windows & Doors. Sapa Building System

Features and benefits:

Ultimate soft closing in any application: Silent System for Intermat hinges

EMF shielding by building materials

Accessory Manual Ventilation Section Model Comfort Circle

Perspective and Space

Evidence of Performance Resistance to wind load Watertightness Air permeability

ScanFlex lever handles

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Wind Mitigation Inspection

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

BUILDING MATERIALS, Wood, Laminated (Page 1 of 3) Viz.: Rafters; Arches; Beams; Joists; Timbers or Planks, structural or roof.

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Check Your Home Security

DIY CABINET REFACING INSTALLATION GUIDE

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

CH. 2 LOADS ON BUILDINGS

3D Drawing. Single Point Perspective with Diminishing Spaces

Networking Cabinets > Part No Capacity Available Colors Height(mm) Width(mm) Depth(mm)

Removable Aluminium posts

8/18/14. Introduction to. Framing. Terminology and Concepts

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

Speed-Mat Rectangle Cutter

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

Combination Unit (shown from interior) WARNING

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Renovation instructions

HOW TO GET TANKS & TOTES CLEANER IN LESS TIME & LOWER COSTS

AUTOMATIC SWINGING DOOR

SPREFIX SPRAY INSULATION _ in the marine market.

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

Frost and Cooper Renovations

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

84 part video tutorial training course. The course is 100% free with no catches or exclusions. You don

Holes & Selective Laser Sintering

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

Beadboard Wall Bookcase

WINDOW CHANNEL, WEATHERSTRIP & WHISKER STRIP REPLACEMENT FOR 2-DOOR SEDANS

All the above mentioned technical characteristics of the MU 2500 Thermal system indemnify its air and water tightness.

Safety Check ALUMAX Hinge Inspection. Projects completed pre-july 2012

19 DYNAmax Free Standing Server C A B I N E T s

FOR SALE: RECYCLING PLANT FOR. - Aluminum scrap - Light metals - WEEE - Mixed industrial waste BANO PREMAC HYDRO. Single shaft shredder

19 DYNAmax Free Standing Server C A B I N E T s

Perforated Shearwall Design Method 1

STR-600 Plate Dryer. 1. What it s meant for?

HOW-TO LAY HARDBOARD OR PLYWOOD FLOOR OVERLAY

Installation Instructions

MEMORANDUM. General: Foundation:

Chapter 6: Logistics and storage room for wood pellets

Sash Replacement Guide

Technical Advice Note

Routers and machining centres

AD425S Automatic door operator

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Sliding Door Hardware Installation Instructions

March 14, Installation of Bay, Bow and Garden Windows

Plaisance 24. Sliding Systems. Sapa Building System

Drayton Digistat +2RF/+3RF

Combination Unit 5'6" Windows a i o P t

Hinge, Blocker, and Tab Adjustment Guide

How To Test For An Architectural Test

Transcription:

EFFECTA RECOMMENDATIONS FOR WOOD FRAMED PELLET STORAGES 1

TABLE OF CONTENT # 1. BESPOKE WOOD FRAME STORAGE WITH FLAT BOTTOM Page 3: General description Page 4: Example of model in cut away Page 5: Switch over of nozzles and inspection glass Page 6: Placement of suction nozzles. # 2. BESPOKE WOOD FRAME STORAGE WITH INCLINE Page 7: General description Page 8: Example of model in cut away Page 9: Switch over of nozzles and inspection glass Page 10: Placement of suction nozzles.! IMPORTANT NOTICE This document is a directional guide. It is not a detailed technical document. We always recommend a discussion with the pellet supplier before building a pellet storage. This document is available for all European markets and there are differences in between the markets in couplings for filling the storage as well as recommendation on dampening mats etc. 2

# 1. FLAT BOTTOM WOOD FRAME STORAGE ROOM. - Bespoke wood frame storage with a flat bottom. - Gives maximum volume for pellets on a small footprint. - Needs more suction intakes since the pellets isn t falling from an incline. - Recommended frame construction is 145mm x 45mm beams. - Recommended c/c is 450mm. - Recommended board materials can be OSB, plywood or hard board. - A service access placed high preferably close to the filling nozzles. Door opening inwards! - Discuss appropriate coupling for filling with a pellet supplier in your market. - A dampening mat is always recommended on the opposed filling side of the storage. 3

# 1. FLAT BOTTOM WOOD FRAME STORAGE ROOM. 4

# 1. FLAT BOTTOM WOOD FRAME STORAGE ROOM. - If a inspection glass is used real glass (not plexi) is preffered to avoid building static electricity. - The thickness of glass is dependented of window size, ask a professional glazier. - Amount of switch over plates is dependent of amount of suction nozzles. 5

# 1. FLAT BOTTOM WOOD FRAME STORAGE ROOM. - The suction nozzles is recommend to be placed maximum 600mm from wall. - The recommended distance between the nozzles is 1200mm. - Use the amount of nozzles appropriate for the storage size. 6

# 2. INCLINE WOOD FRAME STORAGE ROOM. - Bespoke wood frame storage with incline. Incline must be 45 or more. - Use less suction intakes since the pellets is falling from an incline. - Recommended frame construction is 145mm x 45mm beams. - Recommended c/c is 450mm. - Recommended board materials can be OSB, plywood or hard board. - A service access placed high preferably close to the filling nozzles. Door opening inwards! - Discuss appropriate coupling for filling with a pellet supplier in your market. - A dampening mat is always recommended on the opposed filling side of the storage. 7

# 2. INCLINE WOOD FRAME STORAGE ROOM. 8

# 2. INCLINE WOOD FRAME STORAGE ROOM. - If a inspection glass is used real glass (not plexi) is preffered to avoid building static electricity. - The thickness of glass is dependented of window size, ask a professional glazier. - Amount of switch over plates is dependent of amount of suction nozzles. 9

# 2. INCLINE WOOD FRAME STORAGE ROOM. - The suction nozzles is recommend to be placed maximum 600mm from wall. - The recommended distance between the nozzles is 1200mm. - Use the amount of nozzles appropriate for the storage size. - The flat bottom part below the incline can be anywhere between 300-500mm. Effecta AB Västra Rågdalsvägen 21 43496 Kungsbacka Tel: 0300-22320 Fax: 0300-22320 info@effecta.se www.effecta.se 10