3500/25 Enhanced Keyphasor*Module



Similar documents
3500/40M Proximitor* Monitor

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

3500/62 Process Variable Monitor

3500/93 System Display

3500/22M Transient Data Interface

1701/22 FieldMonitor Management Interface Module

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Dynamic Pressure Charge Amplifier

and Accelerometers

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Power Supplies 3. SDN-P DIN Rail Series

Velomitor Piezo-velocity Sensor

S-series Mass Connection Solutions

Low Frequency Velocity Sensor

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Foxboro Evo Process Automation System

Proximity Transmitters and Seismic Vibration Transmitters

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Cisco 7816-I5 Media Convergence Server

ABB Drives. User s Manual HTL Encoder Interface FEN-31

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Differential-Hall-Effect based Sensors Series A5S

Part Number Revision A, January Monitoring System Rack Configuration and Utilities Guide

DeltaV SISnet Repeater

1900/65A General Purpose Equipment Monitor

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

3DLevelScanner II TECHNICAL DATA SHEET

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ORION TELECOM NETWORKS INC. T1

1900/65A General Purpose Equipment Monitor

1756 ControlLogix Chassis Specifications

L5354 ControlNet Communications Interface

Digital input modules

SEISMIC VELOCITY TRANSDUCER T1-40

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Redundancy Module QUINT-DIODE/40

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

M-series MD Plus Controller

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

NI USB-5681 RF Power Meter Specifications

Rack mounted telephone- and leased line modem for industrial applications

Technical Data Sheet. 3DLevelScanner

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

CompactLogix Power Supplies Specifications

I STAR COMPUTER CO., LTD

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

AXIS T81B22 DC 30W Midspan

Differential-Hall-Effect based Sensors Series A5S Overview

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

DC Electronic Loads 8500 series

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Rosemount 333 HART Tri-Loop

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

8-Port E3/DS3 ATM Line Card Overview

Rosemount 333 HART Tri-Loop

Unidirectional Transmitter/ Receiver Units Introduction

3300 XL NSv* Proximity Transducer System Bently Nevada* Asset Condition Monitoring

TECHNICAL DATASHEET Incremental Encoder RI 80-E

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Regards from the Team at Rheology Solutions.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

PROXPAC XL Proximity Transducer Assembly

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

CompactRIO crio-9052

Inductive sensor NI10-M18-Y1X-H1141

Waveguide Access Point WGA631. Product Guide

How To Build A Cisco Uniden Computing System

Modular I/O System Analog and Digital Interface Modules

Cisco Nexus 7000 Series Power Supply Modules

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Amplifier: AMP Feature Summary

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Repeaters and Mimics Data Sheet

Series 7500 Torque Sensor

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

NI Channel, 60 V, High-Speed, Sourcing Digital Output Module

Series 6000 Torque measured metal bellow coupling

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Vibration analysis and monitoring Compact. Powerful. Modern technology.

1756 ControlLogix I/O Specifications

VOICE RECORDING SYSTEM ISDN PRI / BRI

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

Quick Connect. quick - simple - efficient.

EFC Frequency converters

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Description. Dimensions. Features. precision works better

Overview of Cisco 2600 Series Routers

LOXONE 12 Channel Amplifier

Fibre Optic Solutions for your Test and Instrumentation needs

S-series SQ Controller

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Transcription:

3500/25 Enhanced Keyphasor*Module Bently Nevada* Asset Condition Monitoring Description The 3500/25 Enhanced Keyphasor Module is a half-height, two-channel module used to provide Keyphasor signals to the monitor modules in a 3500 rack. The module receives input signals from proximity probes or magnetic pickups and converts the signals to digital Keyphasor signals that indicate when the Keyphasor mark on the shaft coincides with the Keyphasor transducer. The 3500 Machinery Protection System can accept up to four Keyphasor signals for normal configuration and up to eight Keyphasor signals in a paired configuration. Note: A Keyphasor signal is a once-per-turn or multiple-event-per-turn pulse from a rotating shaft or gear used to provide a precise timing measurement. This allows 3500 monitor modules and external diagnostic equipment to measure shaft rotative speed and vector parameters such as 1X vibration amplitude and phase. The Enhanced Keyphasor Module is an improved 3500 system module. It offers expanded Keyphasor signal processing capabilities over the previous design while maintaining complete downward-compatibility in terms of form, fit and function with existing Keyphasor modules for use in legacy systems. The Keyphasor module, PWA 125792-01, is completely replaced by the more recent 149369-01 module. When a system Keyphasor input is required for Triple Modular Redundant (TMR) applications, the 3500 system should employ two Keyphasor modules. In this configuration the modules work in parallel to provide both a primary and secondary Keyphasor signal to the other modules in the rack. A system with more than four Keyphasor inputs may use a paired configuration provided that there are no more than four primary Keyphasor input signals. A paired configuration requires two consecutive monitoring positions in either the upper/lower or both half-slot positions. Four Keyphasor modules will accept four primary and four backup input channels and provide four output channels (one per module). A configuration of two paired and one non-paired (three Keyphasor modules total) is also possible. In such a configuration, the user may configure the one non-paired Keyphasor (order either two 2-channel or one 1-channel and one 2-channel option) The Isolated Keyphasor I/O module is designed for applications in which the Keyphasor signals are tied in parallel to multiple devices and require isolation from other systems, such as a control system. The Isolated I/O module was created specifically for Magnetic Pickup applications but is compatible with and will provide isolation for Proximitor* applications as long as an external power supply is provided. Note that the intent of this I/O module was primarily to measure shaft speed and not phase. The module can provide phase measurements, but this I/O introduces a slightly higher phase shift than the Non- Isolated I/O version. Figure 1 shows the amount of phase shift that the Isolated I/O modules will add at different machine speeds. Enhanced product features include generation of once-per-turn event signals from multi-event-per-turn inputs, field-upgradeable firmware, and asset management data reporting. Page 1 of 7

Specifications Inputs Power Consumption Signal Input Impedance 3.2 Watts typical. Each Keyphasor Module accepts up to two transducer signals from proximity probe transducers or magnetic pickups. The input signal range is +0.8 V to -21.0 V (Non-Isolated I/O modules) or +5V to -11V (Isolated I/O modules). Signals exceeding this range are limited internally by the module. Passive magnetic pickups require a shaft rotative speed greater than 200 rpm (3.3 Hz). 21.8 k minimum. Signal Conditioning Speed/ Frequency Signal Ranges Input range of 1 to 1,200,000 cpm (0.017 to 20 khz). Supports multiple events per revolution to a maximum of 20 khz. Output range of 1 to 99,999 cpm (0.017 to 1667 Hz) Speed/ Frequency Signal Accuracy Specified at +25 C (+77 F). Non-processed Signals 0.017 to 100 Hz 1 cpm 101 to 500 Hz 8 cpm 501 to 20 khz 1% of cpm Processed Signals Transducer Conditioning Auto Threshold Manual Threshold Hysteresis Outputs Buffered Keyphasor Signals Output Impedance Keyphasor Transducer Power Supply 0.017 to 60 Hz 1 cpm 61 to 150 Hz 8 cpm 151 to 20 khz 1% of cpm Minimum signal amplitude for triggering is 2 volts peak to peak and minimum frequency is 120 rpm (2 Hz). Use for any input above 0.017 Hz (1 rpm for 1 event/revolution). User-selectable from 0 to -20 volts dc. Minimum signal amplitude for triggering is 500 millivolts peak to peak. User-selectable from 0.2 to 2.5 Volts. Two buffered Keyphasor outputs are available at the front of the rack via coaxial connectors. Two buffered Keyphasor outputs are also available at the back of the rack via Euro Style connectors. 504 maximum buffered output impedance. -24 Vdc, 40 ma maximum per channel. Page 2 of 7

Front Panel LEDs European Community Directives: 2006/95/EC Low Voltage OK LED TX/RX LED Indicates when a fault has been detected in the Keyphasor Module. Indicates when the Keyphasor Module is communicating with the Rack Interface Module (RIM). Environmental Limits Operating Temperature -30 C to +65 C (-22 F to +150 F) when used with Keyphasor I/O Module other than the Internal Barrier version. 0 C to +65 C (32 F to +150 F) when used with Keyphasor Internal Barrier I/O Module (Internal Termination). Hazardous Area Approvals North American (01) When used with I/O module ordering options with internal barriers: Ex nc [ia] IIC: Class I, Div 1 AEx nc [ia] IIC: Class 1, Zone 2/0 Groups A, B, C, D per drawing 138547 When used with I/O module ordering options without internal barriers: Storage Temperature -40 C to +85 C (-40 F to +185 F). Humidity 95%, non-condensing. Compliance and Certifications EMC Standards: EN 61000-6-2 Immunity for Industrial Environments EN 55011/CISPR 11 ISM Equipment EN 61000-6-4 Emissions for Industrial Environments European Community Directives: EMC Directive 2004/108/EC Electrical Safety Standards: EN 61010-1 ATEX (02) Ex nc [L] IIC: Class I, Div 2 AEx nc IIC: Class 1, Div 2 Groups A, B, C, D per drawing 149243 For Selected Ordering Options with ATEX/CSA agency approvals: For ATEX agency approval ordering options with internal barriers: II 3/(1) G Ex nc[ia Ga] IIC T4 Gc T4 @ Ta = -20 C to +65 C (-4 F to +150 F) Page 3 of 7

For ATEX agency approval ordering options without internal barriers: II 3/(3) G Ex nc[nl Gc] IIC T4 Gc 0.34 kg (0.76 lbs.). I/O Module Dimensions (Height x Width x Depth) T4 @ Ta = -20 C to +65 C (-4 F to +150 F) 241.3 mm x 24.4 mm x 103.1 mm (9.50 in x 0.96 in x 4.06 in). Brazil (02) For Selected Ordering Options with ATEX/North American agency approvals: BR-Ex nc[nl] IIC T4 South Africa (02) For Selected Ordering Options with ATEX/North American agency approvals: Ex ncal [ia] IIC T4 Ex ncal [L] IIC T4 Note: When used with Internal Barrier I/O Module, refer to specification sheet 141495-01 for approvals information. For further certification and approvals information please visit the following website: www.ge-mcs.com/bently Physical Main Module Dimensions Height x Width x Depth) 119.9 mm x 24.4 mm x 256.5 mm (4.72 in x 0.96 in x 10.10 in). Weight Weight 0.46 kg (1.01 lbs.). Rack Space Requirement Main Module 1 half-height front slot. The half-height main modules require a special mounting adapter for mounting in the fullheight slots. The user can place the main modules in any one of the 14 available slots. Each rack may have no more than two main modules, one in a top half-slot and one in a bottom half-slot. I/O Modules 1 full-height rear slot. Ordering Considerations General External Termination Blocks cannot be used with Internal Termination I/O modules. When ordering I/O Modules with External Terminations, the External Termination Blocks and Cables must be ordered separately. There are a number of technical considerations involved in using the expanded signal processing functions of the Enhanced Keyphasor Module. A qualified Bently Nevada sales representative should be consulted prior to specifying or ordering modules for such applications. Page 4 of 7

Internal Barrier I/O Module Product Description Enhanced Keyphasor Module 3500/25-AXX-BXX-CXX A: Number of channels Consult the 3500 Internal Barrier specification sheet (part number 141495-01) if the Internal Barrier Option is selected. 0 1 Single half-height 2-channel Keyphasor card (order for 2- channels) 0 2 Two half-height 2-channel Keyphasor cards (order for 4- Channels) Cables 3500 Keyphasor (KPH) Signal to External Termination (ET) Block Cable 129530-AXXXX-BXX A: Cable Length 0 0 0 5 5 feet (1.5 metres) 0 0 0 7 7 feet (2.1 metres) 0 0 1 0 10 feet (3 metres) 0 0 2 5 25 feet (7.5 metres) 0 0 5 0 50 feet (15 metres) 0 1 0 0 100 feet (30.5 metres) B: Assembly Instructions 0 1 Not assembled 0 2 Assembled Spares 149369-01 Enhanced Keyphasor Module Note: This module may be ordered as a direct plug-in replacement for Keyphasor Module 125792-01. B: Type of I/O Module 0 1 I/O module with Internal Terminations 0 2 I/O module with External Terminations 0 3 Internal Barrier I/O with Internal Terminations 0 4 Isolated I/O module with Internal Terminations (Designed for use with Magnetic Pickups) 0 5 Isolated I/O module with External Terminations (Designed for use with Magnetic Pickups) C: Agency 0 0 Not required 0 1 CSA/NRTL/C (Class 1, Div 2) 0 2 ATEX/CSA (Class 1 Zone 2) Note: Agency C 02 is only available with Ordering Options B 01 and B 03. External Termination Blocks 128718-01 Keyphasor External Termination Block (Euro Style Connectors) 128726-01 Keyphasor External Termination Block (Terminal Strip Connectors) 125800-01 Keyphasor I/O Module (Internal Terminations) 126648-01 Keyphasor I/O Module (External Terminations) 125800-02 Isolated Keyphasor I/O Module (Internal Terminations) (Designed for use with Magnetic Pickups) 126648-02 Isolated Keyphasor I/O Module (External Terminations) (Designed for use with Magnetic Pickups) 135473-01 Keyphasor I/O Module (Internal Barriers and Internal Terminations. 04425545 Grounding Wrist Strap (single use) 00580438 Connector Header, Internal Termination, 4-Position, Green 00502133 Connector Header, Internal Termination, 12-Position, Blue 129770-01 Keyphasor Module Manual Half-height Card Adaptor: 125388-01 Half-height Chassis 125565-01 Card Guide 04300111 Assembly Screws (Order Qty. 3) Page 5 of 7

Figures and Tables Isolated I/O Phase Error 7 6 Phase Error (deg) 5 4 3 2 1 0 0 20000 40000 60000 80000 100000 120000 RPM Figure 1 Page 6 of 7

Figure 2: Front and Rear View of Keyphasor module 1) Buffered Transducer Outputs 2) I/O Module, Isolated Internal Termination 3) I/O Module, Isolated External Termination 4) I/O Module, Non-Isolated Internal Termination 5) I/O Module, Non-Isolated External Termination 6) Barrier I/O Module, Internal Termination All specifications are subject to change without notice. * Denotes trademarks of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company. 1999 2013 Bently Nevada, Inc. All rights reserved. Printed in USA. Uncontrolled when transmitted electronically. 1631 Bently Parkway South, Minden, Nevada USA 89423 Phone: 775.782.3611 Fax: 775.215.2873 www.ge-mcs.com/bently Page 7 of 7