STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM



Similar documents
Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

CONDENSATION IN REFRIDGERATED BUILDINGS

Renovating Your Basement

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

EcoTouch Insulation with PureFiber Technology

Water Damage & Repair

ROOFS, SNOW AND ICE DAMS

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Building Owners Guide to a Duro-Last System!

ABSeam Panel Overview and Installation Instructions

CHAPTER 7: Building Systems ROOFING SYSTEMS

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Molds and mildew are fungi that grow

Asphalt Shingle Application Requirements

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

THE USE OF STEEL BUILDING PANELS FOR ANIMAL CONFINEMENT

CONDENSATION. Section Break (Next Page)

EAST LYME HIGH SCHOOL

Answers to Your Questions from the Webinar

Roof Insulation Building. Energy. Environment friendly e-library

Fiberglas, Exterior Wall Thermal Insulation

) and air spaces (R a

Preventing Ice Dams on Roofs

GigaCrete Specification PlasterMax

ROOF CONDENSATION: A COSTLY PROBLEM

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Chapter 3 Pre-Installation, Foundations and Piers

Removable Insulation Blankets from A to Z

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Underwriters Laboratories Testing Information

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

Low-slope reroofing guidelines

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Insulating Unvented Attics With Spray Foam

Page & Turnbull imagining change in historic environments through design, research, and technology

Housing Fact Sheets. Moisture Condensation at the Windows

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

Avoiding Air Barrier Pitfalls

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

The Optimum Basement Wall

Insulation R-Value Comparisons

Waterproofing and interior insulation for basements takes new twist in technology.

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

What is Seismic Retrofitting?

THE IC Y N E N E AD V A N T A G E

Insulating Basements: Part 3 Basement Wall Systems

Asbestos Management Program

GreenGuard Housewrap Installation Guide

Heating Load Calculation

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Foundation. Foundation

Analysis II Façade Redesign: Architectural Precast Panels

State of Connecticut Department of Public Health RADON PROGRAM

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Glossary of Heating, Ventilation and Air Conditioning Terms

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Tremco Fire Protection Systems Group Technical Bulletin

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

COMMONLY USED RESIDENTIAL BUILDING CODES

BLACK JACK ALL WEATHER ROOF COATING

COMMERCIAL BUILDING APPLICATIONS

Steam System Best Practices Condensate System Piping

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

Why is my air conditioner dripping on my customers?

Preformed Metal Roofing and Siding

VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10

Refrigeration Installation 101

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

Report on Sanctuary/Chancel Crawl Space Inspection. St. John in The Wilderness, 2896 Old Lakeshore Road Bright s Grove. Project No.

Best Practices for Crawl Space Insulation

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Refrigeration Manual. Part 3 - The Refrigeration Load

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Structural Failures Cost Lives and Time

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Post-insulation of cellar ceiling and cellar walls

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

Hunter College school of Social Work Thesis Proposal

B. Types of mechanical insulation specified in this section include the following:

Natatorium Building Enclosure Deterioration Due to Moisture Migration

Continuous Insulation Using Polyiso Wall Sheathing

Transcription:

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC. 7819 Broadview Road Cleveland, OH 44131 1.800.522.4522 Tel 216.642.1200 Fax 216.642.1166 www. stayflex.com

Twenty-year case histories validate the ability of the Stayflex System, used in both new and existing pre-engineered steel buildings, to provide the lowest initial and long-term operating costs in corrosive and wet environments. When specifying buildings having corrosive and wet environments, two primary objectives exist: 1. Provide a building that has the lowest construction and long-term maintenance costs. 2. Provide options to accommodate initial and future budgets. This document summarizes how the Stayflex Corrosion Control and Thermal Insulation System in conjunction with pre-engineered steel buildings enables specifiers to accomplish these two objectives in a manner not possible with any other building technology. Steel buildings are very cost-effective, compared to alternative construction methods such as concrete buildings, but often corrode rapidly in corrosive and wet environments, discouraging its use by specifiers for projects having these types of environments. Uninsulated or poorly insulated steel roofs, siding and structural steel can result in the formation of condensation which significantly accelerates corrosion of steel building components. Elimination of condensation in pre-engineered steel buildings in corrosive and wet environments is critical for longterm, cost-effective performance. Important issues: 1. Condensation is the change of the physical state of water vapor from the gas phase into liquid phase. Condensation (dew) will form when the temperature of the substrate is cooler than the temperature of the water vapor (humidity) present. Dew point is the temperature to which air must be cooled for water vapor to condense into water. The boxed area in the body of Table 1 shows typical dew point temperatures in buildings having corrosive and wet environments. For example, a building with an interior air temperature of 75 F (from far left hand Temperature column) having 65% relative humidity (from Percent relative humidity line of the table) would reach the dew point (temperature at which condensation will form) when the exterior air temperature is 62 F. 2. Condensation on steel building components accelerates corrosion, particularly if chemical vapors are also present. Complete section loss and structural failure of roof purlins and decking is occurring in less than five years after construction when condensation is not controlled. 3. Over time, condensation formed on the interior surfaces of metal roofs, siding, purlins and girts will infiltrate (saturate) commonly used thermal insulation materials such as fiberglass batt insulation. The presence of moisture, which increases the insulation s thermal conductivity, can lead to near total loss of thermal efficiency. 4. Condensation is eliminated by: A. Installing sufficient thickness of insulation to keep insulation and steel surfaces above the dew point. B. Installing a seamless insulation system to avoid thermal breaks. C. Installing a seamless, effective water vapor barrier to the warm, exposed side of the insulation to prevent water vapor from entering the insulation.

Table 2 summarizes the uniqueness of the Stayflex System compared to alternative thermal insulation systems for pre-engineered steel buildings. Only the Stayflex System has the necessary performance attributes required for long-term, cost-effective performance in corrosive and wet environments. Fiberglass blanket insulation commonly used in metal building construction to save energy or stop condensation has two significant limitations: 1. As shown on Drawing 1, the insulation between the roof and purlins is compressed. This compression reduces its thermal efficiency, resulting in the formation of condensation. Condensed water and chemical vapors are deposited and trapped in the lower horizontal lip of the purlins, accelerating corrosion. 2. Moisture and chemical vapors infiltrate the fiberglass insulation at the seams reducing its thermal efficiency. As moisture builds up within the insulation, the additional weight causes the insulation to sag, opening the seams between the fiberglass blankets. This further exposes the roof deck to the chemical and moisture vapors, accelerating the corrosion of the deck. In an attempt to eliminate water vapor intrusion associated with cellulose, mineral wool and glass fiber insulation materials, reinforced polyester resin (FRP) and stainless steel liner panels fastened to the bottom of the purlins and girts have been tried and evaluated. While conceptually encouraging, actual installations have shown it is virtually impossible to obtain vapor tight seals by various sealing and caulking methods, particularly where the panels butt against structural steel members and around equipment protruding through the panels. Even if good initial seals are achieved, moisture and chemical exposure, building movement and vibration eventually cause opening of the joints, allowing the passage of water and chemical vapor. This leads to the formation of condensation behind the liner panels. The condensation is now trapped, accelerating corrosion. Structure failure can occur since the extent of corrosion can not be seen or detected Sprayed polyurethane foam insulation is a good candidate but can only be used safely and in compliance with building codes if it is covered with a fire-resistant surface. The Stayflex 2505 Thermal Barrier Coating is the only polymer fire-resistant coating for sprayed polyurethane foam that is code compliant. Stayflex 2505 is made with the same generic polymers as those used to make other chemical resistant FRP products such as corrugated roofing and siding, grating, tanks and piping, having excellent performance for over 50 years in the corrosive and wet environments. Typically, other fire protective products for sprayed polyurethane foam are fibrous or cementitious. Their high permeability prevents their long-term performance in wet environments and such applications are actually discouraged by their manufacturers. As shown on Drawing 2, the Stayflex System encases all steel surfaces and provides unique performance by: 1. Insulating all steel to prevent condensation. 2. Eliminating horizontal surfaces of purlins. 3. Providing an excellent chemical and fire resistant surface. 4. Providing a highly impermeable barrier to block air, moisture and chemical vapors thus preventing further steel corrosion and eliminating future steel replacement. 5. Strengthening the roof to improve longevity and safety.

Additional performance benefits provided by the Stayflex System include: 1. Improved wind resistance. 2. Improved live load capabilities. 3. Reduced sound transmission. The most cost-effective construction method that will provide long-term performance in corrosive and wet environments is to construct a pre-engineered steel building with the Stayflex System applied to all the exposed interior surfaces of the building. As shown on Tables 3 and 4, construction costs should be approximately $24.00 - $28.00 per square foot of floor area for a pre-engineered steel building with a 1 4 thickness of the Stayflex System. If funds cannot be made available to encase all surfaces at the time of initial construction, the most prudent first step is to install the Stayflex System on the underside of the roof deck and supporting structural steel in direct contact with the roof deck since these components usually are the most susceptible to condensation and corrosion. Other steel surfaces can be encased later as funds become available. Table 5 illustrates the thermal efficiency of the Stayflex System, which reduces energy consumption up to 98% compared to an uninsulated steel building. Preferred Solutions, Inc. welcomes the opportunity to discuss technical, cost and case history information with building owners, architects and engineers to develop designs and specifications for constructing the lowest cost, highest performance buildings for harsh environments.

Dew Point Temperatures TABLE 1 Percent relative humidity Interior Temp. ºF. 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 5-35 -30-25 -21-17 -14-12 -10-8 -6-5 -4-2 -1 1 2 3 4 5 10-31 -25-20 -16-13 -10-7 -5-3 -2 0 2 3 4 5 7 8 9 10 15-28 -21-16 -12-8 -5-3 -1 1 3 5 6 8 9 10 12 13 14 15 20-24 -16-11 -8-4 -2 2 4 6 8 10 11 13 14 15 16 18 19 20 25-20 -15-8 -4 0 3 6 8 10 12 15 16 18 19 20 21 23 24 25 30-15 -9-3 2 5 8 11 13 15 17 20 22 23 24 25 27 28 29 30 35-12 -5 1 5 9 12 15 18 20 22 24 26 27 28 30 32 33 34 35 40-7 0 5 9 14 16 19 22 24 26 28 29 31 33 35 36 38 39 40 45-4 3 9 13 17 20 23 25 28 30 32 34 36 38 39 41 43 44 45 50-1 7 13 17 21 24 27 30 32 34 37 39 41 42 44 45 47 49 50 55 3 11 16 21 25 28 32 34 37 39 41 43 45 47 49 50 52 53 55 60 6 14 20 25 29 32 35 39 42 44 46 48 50 52 54 55 57 59 60 65 10 18 24 28 33 38 40 43 46 49 51 53 55 57 59 60 62 63 65 70 13 21 28 33 37 41 45 48 50 53 55 57 60 62 64 65 67 68 70 75 17 25 32 37 42 46 49 52 55 57 60 62 64 66 69 70 72 74 75 80 20 29 35 41 46 50 54 57 60 62 65 67 69 72 74 75 77 78 80 85 23 32 40 45 50 54 58 61 64 67 69 72 74 76 78 80 82 83 85 90 27 36 44 49 54 58 62 66 69 72 74 77 79 81 83 85 87 89 90 95 30 40 48 54 59 63 67 70 73 76 79 82 84 86 88 90 91 93 95 100 34 44 52 58 63 68 71 75 78 81 84 86 88 91 92 94 96 98 100 105 38 48 56 62 67 72 76 79 82 85 88 90 93 95 97 99 101 103 105 110 41 52 60 66 71 77 80 84 87 90 92 95 98 100 102 104 106 108 110 115 45 56 64 70 75 80 84 88 91 94 97 100 102 105 107 109 111 113 115 120 48 60 68 74 79 85 88 92 96 99 102 105 107 109 112 114 116 118 120 125 52 63 72 78 84 89 93 97 100 104 107 109 111 114 117 119 121 123 125 5

Comparison of Thermal Insulation and Corrosion Control Systems For Pre-engineered Steel Buildings having Corrosive and Wet Environments TABLE 2 Installation on exposed, interior surfaces of steel siding, roofing and structural members Spray-applied Systems Polyurethane foam systems Insulation material Fiberglass blanket with white vinyl surface Cellulose, mineral wool, glass fibers with cementitious, fibrous fireproofing surface with Stayflex 2505 Thermal Barrier Coating R value per inch 4.0 2.9-3.4 6.1 6.9 Seamless to prevent heat and cold loss through joints Protective surface Thickness 0.10 ne 1/2.062 (1/16 ) Permeability to water vapor (lower rating= more resistance) 0.8 >1 (not recommended by manufacturers for wet enviornments) >1 (not recommended by manufacturers for wet enviornments) 0.09 Seamless to prevent water vapor from entering through seams Chemical resistance Fair Fair Fair Excellent Highly resistant to punctures and cuts TABLE 2 continued on next page 6

TABLE 2 (con t) Installation on exposed, interior surfaces of steel siding, roofing and structural members Spray-applied Systems Polyurethane foam systems Fiberglass blanket with white vinyl surface Cellulose, mineral wool, glass fibers with cementitious, fibrous fireproofing surface with Stayflex 2505 Thermal Barrier Coating Complete insulation system Lowest annual costs Expected service life in humid environments before performance is reduced 1-3 Years 1-3 Years 1-3 Years 25+ years Able to stop steel corrosion by being a barrier to air, moisture and chemical vapors Direct adherence to all steel surfaces Able to maintain original thermal resistance necessary to prevent condensation and heat/ cold loss Adds strength to roofs and siding Can be frequently and easily power washed to maintain good appearance

DRAWING 1 Corrosion stages of roofs and purlins when pre-engineered steel buildings are used in corrosive and wet environments. condensation on purlins Air spaces and seams between fiberglass blanket insulation permit chemical and water vapors to infiltrate and condense on metal roof, causing corrosion and saturation of insulation. Compressed insulation above purlins causes condensation on purlins which accumulates in the lower flange, resulting in corrosion and structural failure.

DRAWING 2 Stayflex Corrosion Control and Thermal Insulation System encases all surfaces of steel roof, structural steel and purlins to eliminate condensation and corrosion Staycell 245-2.0 Spray Polyurethane Foam Insulation Stayflex 2505 Thermal Barrier Coating 9

Construction Costs for Buildings having Corrosive or Wet Environments 30,000 square foot building; shell with foundation only TABLE 3 Cost Range Per Service Construction Method Square Foot Life*** Pre-cast concrete:* $33.00-$40.00 30-40 years Pre-engineered steel buildings: 1. Painted steel and $14.00-$16.00 5-10 years fiberglass batt insulation* 2. With structural steel galvanized and painted with two coats of epoxy paint and roof and wall liner panels* Fiberglass panels $23.00-$26.00 10-15 years Stainless steel panels $28.00-$30.00 10-15 years 3. With Stayflex TM System $24.00-$28.00 40-50 years applied on all steel within the building** * Estimated costs from 2007 National Building Cost Manual. ** See Total Cost section in Table 4. *** Time period when repair or replacement of building components becomes necessary. 10

Estimated Installed Prices Stayflex TM Corrosion Control and Thermal Insulation System installed in 30,000 square foot, pre-engineered steel building TABLE 4 Building Shell with Foundation Stayflex System Thickness* Stayflex System 1 2 3 4 Roof and purlins Walls and girts Columns and beams $210,000 $60,000 $50,000 $240,000 $70,000 $50,000 $270,000 $80,000 $50,000 $300,000 $90,000 $50,000 $320,000 $360,000 $400,000 $440,000 Pre-engineered steel building 30,000 square foot steel building** $400,000 $400,000 $400,000 $400,000 Total cost Pre-engineered steel building with Stayflex System $720,000 $760,000 $800,000 $840,000 Cost per square foot of floor $24.00 $25.33 $26.67 $28.00 * Thickness on underside of roof and interior of siding; 1 on all other surfaces ** Estimated costs shown in National Building Cost Manual for the following steel building: Dimensions: 100 feet wide; 300 feet long; 14 foot eave height Roof slope: low-profile, 1 in 12 rise Roof live load design: 20 pounds per square foot Steel sheeting: 26 gauge galvanized on ends, sides and roof Purlins: 8 depth, 60 on center Girts: 8 depth, 48 on center Primary steel columns and beams: 25 on center Foundation: 4 concrete floor with reinforcing mesh and 2 sand fill Window area: 2% of floor area Wiring: Basic Lighting fixtures: Minimum Gravity vents: One medium vent per 2,500 square feet of floor area 11

Energy Savings Provided by Stayflex TM Corrosion Control and Thermal Insulation System 100 x 300 pre-engineered steel building with 14 eave height and 10,100 square feet of siding TABLE 5 Stayflex System Thickness Uninsulated 1 2 3 4 Outside air film 0.17 0.17 0.17 0.17 0.17 Sheet metal 0.00 0.00 0.00 0.00 0.00 Insulation 0.00 6.94 13.88 20.82 27.76 Inside air film 0.61 0.61 0.61 0.61 0.61 Total R 0.78 7.72 14.66 21.60 28.64 BTU loss per hour* 1,799,287 182,455 95,438 64,561 49,123 Energy savings 1,616,832 90% 1,703,857 95% 1,734,726 96% 1,750,164 97% * Calculations are based on insulated areas only and 70 o F. indoor and 35 o F. outdoor temperatures. Consideration is not given to slab loss, infiltration, air changes or any other areas of heat loss or gain. BTU loss per hour = U Value x square feet of surface x temperature differential of interior and exterior in degrees Fahrenheit Uninsulated: U = 1/R = 1/0.78 = 1.282 BTU loss per hour = 1.282 x 40,100 x 35 = 1,799,287 BTUs 1 Stayflex TM System: U = 1/7.72 =.130 BTU loss per hour =.130 x 40,100 x 35 = 182,455 BTUs 2 Stayflex TM System: U = 14.66 =.068 BTU loss per hour =.068 x 40,100 x 35 = 95,438 BTUs 3 Stayflex TM System: U = 21.60 =.046 BTU loss per hour =.046 x 40,100 x 35 = 64,561 BTUs 4 Stayflex TM System: U = 28.54 =.035 BTU loss per hour =.035 x 40,100 x 35 = 44,123 BTUs 12