Natural gas chromatograph LNG gas quality testing



Similar documents
SCADAvantage Network Topology System software products

XFC 6201EX flow computer XSeries products

Line sheets system host software Measurement and automation systems. Connect and control with ABB. Introduction. Making sense of software

Chassis, Power Supply, and Element Management

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Process Instrumentation

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

WEATHER STATION FOR SOLAR FARM MONITORING

Microcor Wireless Transmitter (MWT)

Metering for today s systems

Danalyzer Model 700 Gas Chromatograph

Chromatograph Maintenance and Troubleshooting Class # 5050

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Electronic Flow Switches

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Temperature & Humidity SMS Alert Controller

API Marine. BMS Presentation. Ballast Measurement Systems

Sanitary Type Electronic Flow Switches

Cisco 7816-I5 Media Convergence Server

Application Requirement

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

AUROLEX. Plug and Play Monitoring. The best ways to achieve a cleaner, safer environment

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

USB-500/600 Series Low-Cost Data Loggers and Accessories

4-Channel Thermometer / Datalogger

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Job Aid Pre-Installation Information S8500 Media Server

3500/93 System Display

Fundamentals of Gas Chromatography

EQUIPMENT SPECIFICATIONS

Fully Automated Distillation of Petroleum Products including Biofuels OptiDist - the Optimal Solution

Online Infrared Flue Gas Analyzer Gasboard 3000

Multi-Range Programmable DC Power Supplies 9115 Series

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

In-Line Electronic Flow Switches

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

USB-500/600 Series Low-Cost Data Loggers and Accessories

Installing a Probe. Typical Installation

NC-12 Modbus Application

Current Monitoring Kit

Service catalog Flow products

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

O C M III. Open Channel Flow Monitor

CalMaster2 Field and Software Tools. The world's first battery- and mains-powered in situ flow verification system

USB-500 Series Low-Cost Data Loggers and Accessories

NEW. EVEN MORE data acquisition and test stand automation

Repeaters and Mimics Data Sheet

NetScanner System. Toronto: , Montreal: , Toll Free: ,

MINIMAT-EC-Servo Screwdriver Spindles

UP-213 & UP-266 Pre-Installation Guide

EBS852 (Contrac) Power Electronic Unit

How To Use A Ds340 (Dsp)

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Peel Back Force Tester GPD s Peel Back Force Tester with FORCEWare software is being used to set peel back standards for the entire industry

Residual Gas Analyzers

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

ABB central inverters PVS to 1000 kw

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

AIS750 Series Alarm Annunciator

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

Analog signal converters CC-E I/I Current / current isolators

THERMAL MANAGEMENT SOLUTIONS

Korosi Monitoring System (KMS) Software Manual

MAJORSINE Power Inverter

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Navigator 600 Phosphate Phosphate analyzer. Cost-effective automated monitoring of phosphate for steam raising applications

Alpha/Beta Counting Multi-Detector Systems (MDS)

Rackmount Intelligent Pressure Scanners

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

SNMP Web Management. User s Manual For SNMP Web Card/Box

DCS Data and communication server

CHROMOCTANE O N LINE ANALYZER

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

TrueAlarm Fire Alarm Systems

IntesisBox Modbus Server SAMSUNG Air Conditioners

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Model: DC-A2IO Advanced HVAC Controller

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Energy Monitoring Solutions

Application Server V240 Platform

For Multi-Parameter Meters see mvx

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

1. SAFETY INFORMATION

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

2-Bay NAS Media Server Enclosure (1 x 1 TB) TN-200T1 (v1.0r)

Transcription:

Application description AD/2102760-EN Natural gas chromatograph LNG gas quality testing Introduction The portable NGC8206 is a natural gas chromatograph designed for installation in a vehicle or mounted in a building for connection to a fixed sample point. The NGC is easily powered, either from the vehicle s 12Vdc system or from an AC power supply. Its low power operation means you can maintain continuous power on the unit, thus keeping it at operating temperature and assuring it is ready for immediate use on site. The standard Model 8206 can be used for station mounted applications. Features Five minute cycle time Reliable and easy to operate Alarming on component concentrations Analysis report before unloading From the spot analysis the following are calculated: Relative density Heating value VOS (velocity of sound) GPM (gallons of liquid per thousand cubic feet) Wobbe index

LNG gas quality testing Modular design includes Portable GC interface allows user analysis customization Modular software application based plug in software modules Manifold module (internal tubing now replaced by manifold) Analysis section contains stream selection solenoids, pressure regulation, 32 bit digital detector electronics and a dual-train chromatograph in a single, replaceable module 32 bit digital, low-power controlling electronics, using Windows CE (internal to GC unit) Microsoft Windows 2000 or XP based man-machine interface software (PCCU 32) USB MMI port connectivity Ethernet connectivity Lithium battery-backed RAM Two remote serial digital communications ports; one local port Comprehensive diagnostics and wizards available to users Audit-quality historical data; date and time stamped Operational fault/warn alarms available Detectors constant temperature, glass encapsulated thermistor beads for rugged service and long life. Will not burn out on loss of carrier. Dual 10 port valves have no moving metal parts. Low utility usage low-power, low-carrier, no instrument air required On demand or scheduled automatic calibration and diagnostics 2 AD/2102760-EN LNG gas quality testing

Description The truck is moved as close to the sample point as is practical. The Operator will initiate the cycle to start when the process is connected and the piping is purged. The Sample System on the NGC ensures that the sample from the truck is representative of the process and that the NGC is ready to run samples. Reports will be printed at the end of the analysis cycles and alarming will occur should the sample not meet the load requirements. The NGC8200 analyzes each sample utilizing established chromatographic techniques. The resulting information consists of mole percent values for the following: Air (Contains N2, Ar, CO and O2 but not CO2), C1, CO2, C2, C3, IC4, NC4, NeoC5, IC5, NC5, C6+ The NGC8206 measures a C6+ (back flushed) peak. Users may input the results of a comprehensive lab analysis that reflects the split or ratio of C6 through C10 components. This ratio can be used in subsequent analyses and energy calculations. Calculated values include: Relative density (specific gravity) Btu/CV (heating) value GPM (gallons of liquid per thousand cubic feet) Wobbe index LNG gas quality testing AD/2102760-EN 3

LNG gas quality testing Historical data The NGC8206 is designed to retain historical data. This data can be used for custody transfer needs, verify transmitter operation over time, and provide a limited data backup for communication link reliability. In addition, various CSV file outputs are available to download the analysis data into spreadsheet based company specific data sheets, and outputs to 3rd party gas accounting packages. The default¹ memory configuration provides the most recent 480 analysis cycles containing: Normalized components Un-normalized components Ideal Btu/CV Real Btu (wet and dry) / CV (superior and inferior) Relative density (specific gravity) Density GPM Wobbe index Alarms Stream averages for the (default¹) 840 last hours, 35 last days and the most recent last month analyses. Operational Parameters for the (default¹) last 480 cycles (Diagnostics Report): Selected peak times Selected peak areas Ideal Btu/CV Carrier regulator pressure Oven temperature Ambient temperature Sample pressure Detector noise values Detector balance values Audit logs (Default¹) Last 480 alarms Last 480 events Data retained by the NGC8206 can be collected via a remote communication link or by the laptop PC local operator interface PCCU 32. 4 AD/2102760-EN LNG gas quality testing

Equipment The equipment used for this analysis consists of the standard Model 8206 mounted either as a Mobil mount or standard two in pipe mount enclosure. All the valves, gauges and sample conditioning modules will be provided with the equipment, depending on the options Reports Default¹ The default memory configuration will provide for the data storage above. User may reallocate the memory that is available. Available options Sample and GC Rotometers 120/240 VAC / 24 VDC to 12 VDC power supply Modular Sample System for Non-pipeline quality Natural gas and Sample transport lag-time needs: Type 4 w/ liquid shut-off Temperature Compensation Probes: Fixed Retractable Regulators, carrier and calibration blend Start up/calibration/validation gas sample (+2% Cal Blend) Export crating Tool kit Various maintenance kits On board digital 1/4 VGA display with multiple screen access USB (Host and Client) and Ethernet ports SD memory cards Feed-Through heater Heat trace internal and external tubing LNG gas quality testing AD/2102760-EN 5

LNG gas quality testing Specifications Dimensions Weight Weatherproof construction Carrier gas Analysis time Repeatability Temperature range (storage) Temperature range (normal) Moisture Supply voltage Power consumption 9.5" high x 14.3" wide x 16" deep (24.13 cm x 36.32 cm x 40.64 cm) Approximately 38 lb. (17 Kg) Shipping Weight: 45 lb. (20.4 Kg) No classification Helium (consumption rate < 20 cc/minute during analysis cycle Approximately five (5) minutes; cycles may be scheduled by user ± 0.125 Btu @ 1,000 Btu; (± 0.0125%) @ ambient; ± 0.25 Btu @ 1,000 Btu (± 0.025%) over temperature range of 0 to 131 F 22 F to +140 F (-30 C to 60 C) 0 F to 130 F (-18 C to 55 C) 95% relative humidity non-condensing 110 V AC, 60 Hz or 250 V AC, 50 Hz, 24 V DC (16-28 V DC) or 12 V DC (10.5-15 V DC) Nominal operation @ 0 F ( 18 C) = 7 Watts; (650 ma); Start up @ less than 3 amps (45 Watts @ 15 V DC) Certifications Communications supported Protocols supported Other specifications General purpose Two serial digital ports, software selectable for RS-232, RS-485, or RS-422. One USB MMI (RS-232 or USB). Optional USB hub (host and client) and Ethernet ports. Totalflow Remote / Local MMI Totalflow/TCP Modbus / TCP Server Modbus / TCP Client, Modbus ASCII or RTU (Modicon, WordSwap, or Danalyzer) DSFG (future) Designed for pipeline-quality natural gas, 800 to 1500 Btu per standard cubic foot (29.8 to 55.9 megajoules/meter3)1 with less than 100 PPM H2S Calculations per: GPA 2172-96 (Z by AGA 8 or single viral summation) and 2145-03, ISO 6976-95; meets ISO 12213-2 by AGA 8 detail: (in the future ASTM D 3588, GOST and ISO mass) Meet or exceeds GPA 2261-99 for linearity Four stream capability. Manual calibration required with 4 sample streams Single auto calibration stream and 3 sample streams, or 2 auto calibration streams and 2 sample streams 6 AD/2102760-EN LNG gas quality testing

LNG gas quality testing AD/2102760-EN 7

Contact us ABB Inc. Process Automation Toll-free: + 1 800 442 3097 Quotes: totalflow.inquiry@us.abb.com Orders: totalflow.order@us.abb.com Training: totalflow.training@us.abb.com Support: totalflowsupport@us.abb.com Main Office 7051 Industrial Boulevard Bartlesville, OK 74006 Ph: +1 918 338 4888 California Office 4300 Stine Road, Suite 405-407 Bakersfield, CA 93313 Ph: +1 661 833 2030 Texas Offices 3700 West Sam Houston Parkway South, Suite 600 Houston, TX 77042 Ph: +1 713 587 8000 3900 South County Road 1290 Odessa, TX 79765 Ph: +1 432 563 5144 150 Eagle Ford Road Pleasanton, TX 78064 Ph: +1 830 569 8062 www.abb.com/upstream Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2015 ABB Inc. All rights reserved Product webpage AD/2102760-EN 05.2015 Kansas Office 2705 Centennial Boulevard Liberal, KS 67901 Ph: +1 620 626 4350