Compliant Healthcare Technologies, LLC. NFPA 99, 2012 Changes" November 13, 2013!



Similar documents
Element D Services Plumbing

Medical Gas Installation Handbook A-Z. A guide to installing Medical Gas equipment from alarm panels to zone valves.

Utility Distribution Systems

2007 Medical Gas System Cylinder Storage, Piping & Alarms Reminder List

2013 Medical Gas Cylinder Storage, Piping & Alarms System Reminder List

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

ELECTRICAL EMERGENCY SYSTEM PLAN REVIEW OVERVIEW OF CODE REQUIREMENTS

4 Installation Requirements

Ammonia Detection System Codes and Design Specifications

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

General Fire Code Requirements Within Commercial Tenant Spaces

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

SECTION MORTUARY REFRIGERATORS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

5/3/2010. Article 500 address the requirements for hazardous locations: Wiring Equipment

Antifreeze Solutions in Residential Fire Sprinkler Systems

Medical Air Systems: Scroll

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

Health Choice Enterprises ASSE Medical Gas Course

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

OptiNet Applications. A Review of the Unique Requirements for a Facility Monitoring System. White Paper Series

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

Cooktop Low-Profile Ventilation Hoods

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Lifeline Fire Protection Cable Systems. Cables

ASX7-4-IOM-7 J

NFPA31FuelOilPiping 1 Revised

MERCER ISLAND FIRE DEPARTMENT FIRE COMMERCIAL SPRINKLER STANDARDS

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

PLAN REVIEW GUIDE FOR FIRE ALARM

I.S :2013 Fire Detection & Alarm Systems

GENERAL ELECTRICAL REQUIREMENTS

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

Overview of Standards for CO Detection Products

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Test Code: 8297 / Version 1

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Sanitary Type Electronic Flow Switches

Grounding & Bonding Why it is done And How to Install Properly

Requirements for Electrical Installations

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

ADOPTION OF THE NATIONAL ELECTRICAL CODE, 2005

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Questions and Answers for Heating and A/C Contractors

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

2. What building projects are exempted? (permit not required)

I.S :2013 Fire Detection & Alarm Systems

Building Code Clarifications - 7. Fire Resistance

OHIO MEDICAL CORPORATION. Medical Gas Outlets. Installation and Maintenance Manual

East Central College HANSEN HALL LEVEL 300/400 RENOVATIONS PACKAGE

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Errata NFPA 70. Proposed 2014 Edition

Requirements for Hydrogen Storage and Use

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Explosion-Proof Electric Unit Heaters

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

The following definitions apply with regard to requirements specified in this document:

UNDERSTANDING. C&M Corporation 51 South Walnut Street, Wauregan, CT Phone: Fax:

Technical Specifications for West Campus Data Center HVAC System

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

Name Of Occupancy Date. Yes No Describe

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Winnipeg Fire Department Fire Prevention Branch

A Code Review for Emergency Generators and Indoor Use of Portable Generators

Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

Aurora Mall. Aurora (Denver), Colorado

FIRE ALARM SYSTEM SUBMITTAL CHECKLIST AND APPLICATION

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

IMPACT ALARM SYSTEM FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION

BELMONT FIRE DEPARTMENT FIRE ALARM SYSTEM REQUIREMENTS BFD-OFM

Automatic Fire Sprinkler Submittal Requirements

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

2010 Residential Water Heater Replacement Check List

FIRE ALARM SYSTEM CHECKLIST For Addressable Systems PRIOR TO INSPECTION

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

IEQ-15 Air Distribution System

Terms and Definitions In Canada

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

Engineers Edge, LLC PDH & Professional Training

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

Transcription:

Compliant Healthcare Technologies, LLC NFPA 99, 2012 Changes November 13, 2013!

The standard is now a CODE!! The NFPA 99 has now been upgraded from a Standard to a Code. This will put it in the same light as NFPA 70, and NFPA 101 Life Safety Code. The code is now intended to be law in its entirety versus simply a reference.

Who is the new AHJ 1.3.4?!! The governing body of the facility or its designee shall establish the following areas in accordance with the type of patient care anticipated and with the following definitions of the classification: 1. Critical care rooms 2. General care rooms 3. Basic care rooms 4. Support care rooms Anesthesia. It shall be the responsibility of the governing body of the health care organization to designate anesthetizing locations. 1. Deep Sedation/Analgesia 2. General Anesthesia 3. Minimal Sedation 4. Moderate Sedation (Conscious Sedation)

Lost your levels for categories?! Who Determines The Category? In the NFPA 2005, we had levels describing the facilities requirements, Level 1, Level 2, and Level 3. Often times this created confusion because of the conflict between Chapter 3 definitions and the definitions of care in chapters 13-21. New in 2012 Chapter 4 Fundamentals: - Category 1. Facility systems in which failure of such equipment or system is likely to cause major injury or death to patients or caregivers shall be designed to meet system Category 1 requirements as defined in this code. - Category 2. Facility systems in which failure of such equipment or system is likely to cause minor injury to patients or caregivers shall be designed to meet system Category 2 requirements as defined in this code. - Category 3. Facility systems in which failure of such equipment is not likely to cause injury to patients or caregivers, but can cause patient discomfort, shall be designed to meet system Category 3 requirements as defined in this code

Do you know what category you are?! For the purpose of this presentation, we will be only covering that which applies to Category 1

New 5.1.1.5, 5.1.1.6, and 5.1.1.7! New facilities and facilities making changes must meet the requirements from 5.1.2 through 5.1.12.3.14.5 and 5.1.14.4.2. This includes altering any piping. This is the full standard and verification testing. Existing facilities must meet 5.1.14.4.3 through 5.1.14.4.9 and 5.1.13 through 5.1.15. This is the maintenance requirements added in this edition. New and existing facilities are also required to meet 5.1.14.3 and 5.1.14.4.1, this would reference labeling and proper record keeping.

Temperature exposure for gas storage 5.1.3.3.1.8 through 5.1.3.3.1.13! The new temperature range is per manufacturer, but no les than -20 F compared to 20 F. Oxygen storage was specific and referenced a 20,000 ft 3 maximum for indoor storage. The same capacity also applies to inert gases and their systems. Carbon dioxide and nitrous oxide still have their individual requirements for bulk storage.

Outdoor enclosures 5.1.3.3.2(3)!

Manifold room electrical devices 5.1.3.3.2(10)! The height requirement of 5 feet has been removed and replaced with protect devices from physical damage. Medical gas storage room ventilation 9.3.7! Natural ventilation requirement has moved to chapter 9 for HVAC. We now have a calculation for natural ventilation of 24in 2 /1000ft 3 of fluid designed to be stored at STP. In no case less than 72in 2. Mechanical ventilation should be continuous negative pressure. Exhaust shall be at a rate of 1 cfm per 5ft 3 of fluid designed to be stored. Not less than 50 cfm nor greater than 500 cfm. The means of make up air can be from under a corridor door up to 50 cfm or 15% of the room exhaust per NFPA 90A. Chapter 9 is now heating, ventilation, and air conditioning

A decision chart for ventilation!

Where can I pipe to 5.1.3.5.2?! Only to areas where the gases will be used under the direction of licensed medical professionals for the purposes congruent with the following: 1. Direct respiration of patients 2. Clinical application of the gas to patient 3. Medical device applications directly related to respiration 4. Power for medical devices used directly on patients 5. Calibration of medical devices 1through 4

Splitting system pressure 5.1.3.4!

Alarms wiring 5.1.9.1! Alarm wiring still needs to meet the NFPA 70, 517.30(C)(3), we now have the correct reference. The wiring does not have to be continuous run; splicing is allowed. The following are allowable methods to protect alarm wiring: Conduit Free air Wire Cable tray Raceway Alarm wiring must not be interchangeable, unable to cross connect.

NFPA 70 571.30(C)(3)! (3) Mechanical Protection of the Emergency System. The wiring of the emergency systems in hospitals shall be mechanically protected. Where installed as branch circuits in patient care areas, the installation shall comply with the requirements of 517.13(A) and (B). The following wiring methods shall be permitted: 1. Nonflexible metal raceways, Type MI cable, or Schedule 80 PVC conduit. Nonmetallic raceways shall not be used for branch circuits that supply patient care areas. 2. Where encased in not less than 50 mm (2 in.) of concrete, Schedule 40 PVC conduit, flexible nonmetallic or jacketed metallic raceways, or jacketed metallic cable assemblies listed for installation in concrete. Nonmetallic race ways shall not be used for branch circuits that supply patient care areas. 3. Listed flexible metal raceways and listed metal sheathed cable assemblies in any of the following: a. Where used in listed prefabricated medical head walls b. In listed office furnishings c. Where fished into existing walls or ceilings, not other wise accessible and not subject to physical damage d. Where necessary for flexible connection to equipment 4. Flexible power cords of appliances or other utilization equipment connected to the emergency system. 5. Cables for Class 2 or Class 3 systems permitted by Part VI of this Article, with or without raceways. Informational Note: See 517.13 for additional grounding requirements in patient care areas.

Master alarm wiring 5.1.9.2.3.6!

Medical air!! The medical air intake location has been clarified to align with the AIA Guidelines and FGI Guidelines. The intake makeup can be the same as vacuum exhaust, allowing for a variety of coppers or stainless steel (5.1.3.6.3.12(F). Dew point is corrected in both locations, medical air quality and master alarm activation to 35 F.

Clarify medical air intake, 5.1.3.6.3.12!

Medical gas installations!! More restrictive use of threaded joints this section was clarified. Special fitting specifications was clarified, and prohibited joints for other type of quick connect fittings was clarified. No longer required to come out above centerline of the main. Clarification of the term for those installing and working on medical gas systems, now all personnel must have credential, no supervisor. Initial vacuum testing shall be at 150 psi with pressure piping system. Authority Having Jurisdiction must now witness 24 hour standing test and attest. Medical air systems are required to operate for 12 hours at 25% duty versus 24 hours. This must be done prior to patient use.

Maintenance and TJC Considerations! Master alarm sensor locations Valve locations, locking or latching, labeling Area alarms- local versus remote sensors Flex connectors- what are they and what does it mean