Spectrum catalogue 06
LED Indoor LED Retrofit Contents LFL HID 7 8 0 Introduction LED Retrofit Solutions LED Lamps LED Tubes LED Plug-in LED Indoor Solutions Ambient Functional CFL Non-Integrated GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this catalogue are intended as a general guide, and we may change specifications from time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. All lamp drawings are a guide, if further technical details are required please contact your nearest sales office. General conditions of sale GE Lighting products are supplied according to GE s General Conditions of Sale. If you require a copy of these conditions please contact your nearest GE Lighting sales office. Prices A price list is available from all GE Lighting sales offices. Date of Issue May 06 7 7 79 9 8 Feature Architecture Signage Refrigeration Display Lighting High Intensity Discharge Lamps Linear Fluorescent Lamps Compact Fluorescent Lamps Non-Integrated Compact Fluorescent Lamps Integrated Halogen Lamps Incandescent Lamps Specialty lamps Entertainment Lamps Halogen CFL Integrated www.gelighting.com and General Electric are both registered trademarks of the General Electric Company 6 6 68 79 Horticulture Lamps Special Solutions Lamps Drawings / Glossary Sales Offices Incandescent Sales Offices s / Glossary Specialty
Introduction New technologies for a changing world From the first affordable incandescent lamp to today s LEDs, GE Lighting is a company with a heritage built on technological innovation We have been at the forefront of every development in lighting from tungsten, HID mercury and fluorescent to quartz halogen and compact fluorescents. And in the same way that we took these breakthrough technologies from the laboratory to the world s streets, homes, stores and offices, so are we now doing the same with LED. This commercialisation is important. We don t develop new technologies for the sake of it, we do it to enable the world to do things better. Lighting isn t just an overhead, a figure of the cost side of the balance sheet; it is also an extraordinarily powerful tool that affects the way we feel and influences the way we respond to the world around us. These are just some of the ways in which today s lighting technologies are helping to deliver additional value: More productive offices Safer streets Extended shelf life of fresh products Fewer road accidents Increased retail sales Enhanced architectural features More welcoming public spaces Relaxed hospitality environments Reduced light pollution Innovative solutions based on intelligent networks This will dramatically change the way we think of lighting. Instead of being a passive utility to be switched on and off as required, lighting systems will interact with other technologies to deliver a range of benefits unimaginable just a few short years ago. These are two of the systems we have already introduced others will follow: INDOOR POSITIONING SYSTEM Indoor location technology embedded inside LED lighting fixtures enables lighting systems to communicate with nearby smartphones, delivering information or offers specific to the recipient s location. Applications include retail and hospitality industries as well as museums and galleries. LIGHTGRID This is a groundbreaking outdoor wireless control system for street and roadway lights. The system allows for remote operation and monitoring of all lighting fixtures through a Webenabled central management system. The result is energy saving through precise dimming schedules based on need, and more efficient maintenance. Smart systems for even greater benefit We are working on solutions to broader issues too, developing technologies that extend the benefits of LED lighting systems beyond simple illumination. The evolution of modern day LED lighting systems can be broken down into three key phases. The first saw the arrival of LED lighting as a mainstream technology, improving the quality of light while at the same time reducing energy costs. Secondly, we saw the development of the control systems that enable savings and system enhancements through dimming and daylight harvesting. Today we are entering a third phase, where lighting systems integrate directly into the digital network and play a central role in what has become known as the Internet of Things. Reassurance of proven performance The rapid pace of change within the lighting industry has seen the arrival of players without our stability, technical expertise and commitment to innovation. We invented the first visible LED in 96 and have been manufacturing LED lighting solutions since the 990s. We ve pioneered innovations such as modular design and flat LED panels, and we lead the way in terms of standardisation of design, giving you the confidence of knowing that your investment is protected. In short, we re driving the same standards of quality and reliability into solid-state lighting that we ve brought to every other lighting technology over the last 0 years. Tower Bridge London GE SOLUTIONS: LED Architectural Systems, Flood LED
LED Retrofit GE LED LED Retrofit Aesthetics, economy and sustainability Advances in lighting technology in particular the arrival of LED alternatives to traditional lamps make it possible to create dramatically improved lighting systems and at the same time drive significant reductions in the carbon footprint and environmental impact of every street, office, retail store or public building. How is this possible? Firstly, the vastly superior energy efficiency of LED lamps compared with traditional technologies brings immediate running cost savings of up to 90%, and a similar reduction in carbon footprint. Secondly, the outstanding performance of LED lighting quality of light, output and efficacy (lm/w) and high reliability means a longer life, lower maintenance requirements and reduced relamping costs. In addition to this, the development of advanced control tools such as daylight harvesting and presence detection systems builds on this inherent efficiency to deliver even greater cost and energy savings. Global leadership, innovative solutions The sheer breadth of our LED product range means we re able to deliver complete solutions that offer fantastic aesthetics, sustainability, performance and economy. As a global leader, we take our responsibilities very seriously indeed and are working to develop the innovative lighting solutions that will be essential to a more competitive low-carbon economy. Lower energy lamps, longer lasting lamps, less harmful materials they re all ways in which we are helping customers and end users take significant steps towards reducing the carbon footprint and environmental impact of everyday life. How many lumens do you need? Brightness LUMENS Up to 90% greater energy efficiency Reduced CO emissions vs. older technologies Longer life and reduced maintenance requirements Environmentally-friendly: mercury free, lead free No UV or IR emissions W 6W W 8W 0W 0W W 0W 0+ 00+ LED Retrofit Solutions 0W W W 60W 700+ W W W 7W 900+ 8W W 70W 00W 00+ UP TO 90% GREATER ENERGY EFFICIENCY REDUCED CO EMISSIONS VS. OLDER TECHNOLOGIES SMART CONTROLS FOR EVEN GREATER COST/ ENERGY SAVINGS 6 7
LED Retrofit LED Retrofit Solutions LED Retrofit The game-changing impact of LED LED has taken lighting into the digital age. The world of lamps and ballasts has become the universe of chips and drivers; analogue technology has become digital. The significance of this change cannot be overstated. It has transformed the lighting industry. The challenge for many users from the consumer looking to replace a handful of lamps at home to the purchasing manager responsible for a nationwide chain of retail stores has been when to take the plunge and upgrade from traditional technologies to the world of LED. Here at GE we ve made this transition as seamless as possible through the introduction of cost-effective retrofit solutions, products that offer a quick, easy and reliable replacement for less efficient lamps. LED lighting for everywhere The introduction of our latest ranges has made selecting the right product easier than ever, with LED Retrofit Lamp ranges for almost every requirement. Whatever the specific requirements of your industry or application, we have the breadth of range to meet it. CCT CCT describes how warm or cold a light feels. This is extremely important in lighting design as it plays a major role in determining mood and attracting sales. Colour Rendering Index In short, our comprehensive range of LED Retrofit Lamps opens the door to the wealth of benefits offered by this technology outstanding performance, long life and low energy use without the need to invest in new fittings. Colour Rendering Index or CRI is a measurement of how true the colour of an object appears compared with how it would look under natural sunlight. From fresh produce to fashion, from galleries to gastronomy, we can deliver what you need. Easy installation savings up to 90% vs. traditional technologies Long life up to 0 000 hours Low maintenance/replacement costs Future proof modular options Instant light, no warm-up time Beam angle From the wide beam required for general illumination to the narrow spotlight for feature lighting to accentuate a particular product or area, we can provide an extensive choice to meet any requirement. 0K h + EASY INSTALLATION LONG LIFE UP TO 0 000 HOURS FUTURE PROOF MODULAR OPTIONS CCT COLOUR RENDERING INDEX BEAM ANGLE Wyndham Grand Regency Qatar GE SOLUTIONS: LED Smart TM GU0 Dimmable 8 9
LED Retrofit LED Retrofit Solutions LED Lamps LED Retrofit Solutions LED Tubes LED Retrofit Choose from our most comprehensive LED range LED technology has changed the world of lighting forever, delivering major savings in energy, instant illumination and a working life up to x longer than incandescent lamps. At GE we ve made selecting the right product easier than ever, with LED Retrofit Lamp ranges for every need, from low cost to high performance. At the top of the range we have our Precise Lamps, offering high output and great aesthetics. Next there s our extremely popular Smart range, combining the best of both worlds: impressive performance and outstanding efficiency. And for applications requiring maximum affordability, choose our functional LED Start range. Quick and easy switch to energy-saving LED Our unique range of LED Tubes provides a quick and convenient upgrade path for installations of all kinds, allowing users to convert existing T8 Linear Fluorescent Lamps (LFLs) to high quality, energy efficient LED lighting with a simple switch. With products available in plastic and glass design options compatible with magnetic gears in all standards lengths and/or electronic gears (00mm length only), upgrading from LFL couldn t be easier. = LED LAMPS LAST UP TO X LONGER THAN INCANDESCENT LAMPS UP TO 80-90% ENERGY SAVING REDUCED MAINTENANCE COSTS Significant cost savings savings of up to 60% or more Low power consumption High lumens means fewer luminaires required GE LED Precise Very long operating life GE LED Smart Outstanding efficiency GE LED Start Dependable operation and reliability Reduced maintenance.x longer life vs. fluorescents on electro-magnetic gear Excellent lumen maintenance Extra long relamping cycles Premium performance Precise range for aesthetics, energy efficiency, high lumen output and long operating life. Premium products with superior performance High lumen output and energy efficiency Superior colour quality with CRI up to 90 Very long operating life: L70 000 h+ Optimised dimming function and compatibility Mainstream Smart range for applications requiring high performance, reliability and efficiency. High quality performance and reliability Available in General, Decorative and Spotlights Wide range of base, finish and beam angles Outstanding efficiency: 80-90% energy saving Reduced maintenance costs for improved ROI Affordable Start range functional design for dependable operation and reliable performance. Standard performance specifications Dependable operation and reliability Functional and economical design Reliable, high quality light Instant on, no flicker Excellent colour rendering CRI 80+ Colour options 000/000/600K Quick and easy installation Plug-and-play products 600, 00 and 00 mm tubes Fit directly into standard T8 LFL G sockets Rotatable base to adjust lamp into perfect position Environmentally friendly solutions Extremely energy efficient Reduced carbon footprint No harmful lead or mercury Fully compliant with material restriction requirements of RoHS 0
LED Retrofit LED Retrofit Solutions LED Plug-in LED Retrofit LED replacements for plug-and-play simplicity Our range of LED Plug-in products offers quick and cost-effective replacement options for 6W and W CFL Plug-in lamp without the need for tools. GE LED Plug-in replacement lamps provide.x the life of an average CFL and use only half the energy, delivering a more targeted light that requires fewer lumens and reduces waste. The result is a dramatic reduction in operating costs, coupled with equally impressive improvements in the quality of light. With simple and reliable plug-and-play installation for both horizontal and vertical configurations, this is an extremely attractive and easy upgrade option. Significant cost savings savings of up to 60% More targeted light Long life, low maintenance.x longer life vs. average CFL Reduced maintenance costs Excellent lumen maintenance Reliable, high quality light Instant on, no flicker Excellent colour rendering CRI 80+ Colour options 700/000/000/600K Quick and easy installation Available for both horizontal and vertical configuration Plug-and-play for Gq- or GXq- CFL sockets without costly upgrades No installation tools required Environmentally friendly solutions Extremely energy efficient Reduced carbon footprint No harmful lead or mercury Fully compliant with material restriction requirements of RoHS Grosvenor House Dubai GE SOLUTIONS: LED Precise MR6, LED drivers
LED Retrofit LED Retrofit Solutions overview LED Retrofit Precise Smart Start Precise Smart Start Precise TM GU0 Dimmable : GU0 Wattage: 6W Voltage: 0 0V Beam Spread: Rated life: 0 000 h Smart TM GU0 Dimmable : GU0 Wattage:.W,.W Voltage: 0 0V Beam Spread: Rated life: 000 h Start GU0 : GU0 Wattage:.W, W Voltage: 00 0V Beam Spread: Rated life: 000 h Precise TM PAR0 Dimmable : E7 Wattage: W Voltage: 0 0V Beam Spread: Rated life: 0 000 h Smart TM PAR8 : E7 Wattage: W Voltage: 90 0V Beam Spread: 0 Rated life: 000 h Start R0 : E Wattage: W Voltage: 00 0V Beam Spread: Rated life: 000 h LED GU0 Precise TM MR6 Dimmable : GU. Wattage: 7W Voltage: V Beam Spread: Rated life: 000 h Smart TM MR6 : GU. Wattage: 7W,.W Voltage: V Beam Spread: Rated life: 000 h Precise TM R6/PAR0 Dimmable : E7 Wattage: 7W Voltage: 0 0V Beam Spread: Rated life: 0 000 h Smart TM PAR6/R0 : E, E7 Wattage:.W Voltage: 0 0V Beam Spread: Rated life: 000 h LED MR6 LED PAR Smart TM R : G Wattage: W Voltage: V Beam Spread: Rated life: 0 000 h Filament : E7 Wattage: W Voltage: 0 0V Rated life: 0 000 h Bright Stik TM : E7 Wattage: 6W, 0W, 6W Voltage: 00 0V Rated life: 000 h Smart TM R Dimmable : G Wattage: W, W Voltage: V Beam spread: Rated life: 0 000 h Smart TM Omni Dimmable : E7, B Wattage: W, W, 7W Voltage: 0 0V Rated life: 000 h Start GLS : E7, B Wattage: 6W, W, 0W, 7W Voltage: 00 0V Rated life: 000 h LED R LED GLS
LED Retrofit LED Retrofit Solutions overview LED Retrofit Smart Start Premium universal Basic Glass LED Candle Smart TM Crown Deco Dimmable : E, E7, B Wattage: 6W, W Voltage: 0 0V Rated life: 0 000 h Smart TM Crown Deco Dimmable : E, E7, B, B Wattage: 6W, W Voltage: 0 0V Rated life: 0 000 h Start Candle : E, E7 Wattage:.W Voltage: 00 0V Finish: White Rated life: 000 h LED T8 Premium Universal : Wattage: Voltage: Rated life: G 8W 00 77V 0 000 h LED T8 Basic : G, G Rot Wattage: 8W, 0W, 6W, 0W, 7W Voltage: 00 0V Rated life: 0 000 h LED T8 Glass Rotatable : G Rot Wattage: 8W, 0W,,W, 8W, 7W Voltage: 00 0V Rated life: 0 000 h Smart TM Crown Deco Dimmable : E, E7, B Wattage: 6W, W Voltage: 0 0V Rated life: 0 000 h Smart TM Crown Deco Dimmable : E, E7, B Wattage: 6W,.W Voltage: 0 0V Rated life: 0 000 h Start Spherical : E, E7 Wattage:.W Voltage: 00 0V Finish: White Rated life: 000 h LED T8 Glass : G Wattage: 8W, 0W,,W, 8W, 7W Voltage: 00 0V Rated life: 0 000 h LED Spherical, Globe LED T8 Tube Smart LED Plug-ins Smart TM Pygmy : E Wattage:.6W Voltage: 00 0V Rated life: 000 h Smart TM sule G : G Wattage:.6W Voltage: 00 0V Rated life: 000 h Smart TM sule G9 : G9 Wattage:.W Voltage: 00 0V Rated life: 000 h LED pin Plug-in* : Gq- Wattage:.W Rated life: 0 000 h Position: Vertical * Lamp can t be operated directly from Mains voltage, an electronic ballast is needed LED pin Plug-in* : Gq- Wattage:.W Rated life: 0 000 h Position: Horizontal * Lamp can t be operated directly from Mains voltage, an electronic ballast is needed LED Pygmy, sules LED Plug-in 6 7
LED Retrofit LED Retrofit Solutions / LED Lamps LED Retrofit Solutions / LED Lamps Watt Replacement Dimming ability Beam Angle ( ) Rated life L70/B0 (h) LED Retrofit Watt Replacement Dimming ability Beam Angle ( ) Rated life L70/B0 (h) Smart - LED Filament Smart - GLS OMNI 6 7 6 7 7 6 7 7 0 E7 LED/A60 FIL/87/0-0V/E7 H 90980 0 700 No 80 000 A++ 60 6 Start - Bright Stik 6 0 E7 LED 6/STIK/80/00-0/E7/F / 907 70 000 No 0 80 000 A+ 7 6 6 0 B LED 6/STIK/80/00-0/B/F / 900 70 000 No 0 80 000 A+ 7 6 6 0 E7 LED 6/STIK/80/00-0/E7/F / 907 70 000 No 0 80 000 A+ 7 6 6 0 E7 LED 6/STIK/86/00-0/E7/F / 90 70 600 No 0 80 000 A+ 7 6 0 60 B LED0/STIK/80/00-0/B/F / 907 80 000 No 0 80 000 A+ 7 0 60 E7 LED0/STIK/80/00-0/E7/F / 900 80 000 No 0 80 000 A+ 7 6 0 60 E7 LED0/STIK/80/00-0/E7/F / 907 80 000 No 0 80 000 A+ 7 6 0 60 E7 LED0/STIK/80/00-0/E7/F / 90 80 000 No 0 80 000 A+ 7 6 0 60 E7 LED0/STIK/80/00-0/E7/F / 907 80 000 No 0 80 000 A+ 7 6 0 60 E7 LED0/STIK/86/00-0/E7/F / 900 80 600 No 0 80 000 A+ 7 6 0 60 E7 LED0/STIK/86/00-0/E7/F / 900 80 600 No 0 80 000 A+ 7 6 6 00 E7 LED6/STIK/80/00-0/B/F /0 90 000 No 0 80 000 A+ 6 0 6 00 E7 LED6/STIK/80/00-0/E7/F / 900 000 No 0 80 000 A+ 6 6 00 E7 LED6/STIK/80/00-0/E7/F /0 90 000 No 0 80 000 A+ 6 0 6 00 E7 LED6/STIK/80/00-0/E7/F /0 90 000 No 0 80 000 A+ 6 0 6 00 E7 LED6/STIK/86/00-0/E7/F / 9007 600 No 0 80 000 A+ 6 6 00 E7 LED6/STIK/86/00-0/E7/F /0 90 600 No 0 80 000 A+ 6 0 Start - GLS Snowcone 7 0 B LED 7/A60/87/00-0V/B/F HBX/6 90096 70 700 No 60 80 000 A+ 60 07 6 7 0 E7 LED 7/A60/87/00-0V/E7/F HBX/6 90097 70 700 No 60 80 000 A+ 60 09 6 7 0 E7 LED 7/A60/86/00-0V/E7/F HBX/6 90098 00 600 No 60 80 000 A+ 60 09 6 0 60 B LED0/A60/87/00-0V/B/F HBX/6 9007 80 700 No 60 80 000 A+ 60 07 6 0 60 E7 LED0/A60/87/00-0V/E7/F HBX/6 9007 80 700 No 60 80 000 A+ 60 09 6 0 60 B LED0/A60/80/00-0V/B/F HBX/6 9000 80 000 No 60 80 000 A+ 60 07 6 0 60 E7 LED0/A60/80/00-0V/E7/F HBX/6 9000 80 000 No 60 80 000 A+ 60 09 6 0 60 E7 LED0/A60/86/00-0V/E7/F HBX /6 90009 80 600 No 60 80 000 A+ 60 09 6 7 B LED/A67/87/00-0V/B/F HBX/6 90008 0 700 No 60 80 000 A+ 67 07 6 7 E7 LED/A67/87/00-0V/E7/F HBX/6 90990 0 700 No 60 80 000 A+ 67 6 7 B LED/A67/80/00-0V/B/F HBX/6 90006 0 000 No 60 80 000 A+ 67 9 6 7 E7 LED/A67/80/00-0V/E7/F HBX/6 90007 0 000 No 60 80 000 A+ 67 6 7 E7 LED/A67/86/00-0V/E7/F HBX /6 9000 0 600 No 60 80 000 A+ 67 6 6 00 B LED6/A67/87/00-0V/B/F HBX/6 -* 700 No 60 80 000 A+ 67 9 6 6 00 E7 LED6/A67/87/00-0V/E7/F HBX/6 -* 700 No 60 80 000 A+ 67 6 6 00 E7 LED6/A67/86/00-0V/E7/F HBX/6 90096 600 No 60 80 000 A+ 67 6 * Please contact your local account manager. 7 0 B LED 7D/GLS OMNI/87/0-0V/B HBX 90068 70 700 Yes 0 80 000 A+ 60 08 6 7 0 E7 LED 7D/GLS OMNI/87/0-0V/E7 HBX 900067 70 700 Yes 0 80 000 A+ 60 09 6 60 B LEDD/GLS OMNI/87/0-0V/B HBX 900 80 700 Yes 0 80 000 A+ 60 08 6 60 E7 LEDD/GLS OMNI/87/0-0V/E7 HBX 90067 80 700 Yes 0 80 000 A+ 60 09 6 7 B LEDD/GLS OMNI/87/0-0V/B HBX 968 00 700 Yes 0 80 000 A+ 67 6 7 E7 LEDD/GLS OMNI/87/0-0V/E7 HBX 967 00 700 Yes 0 80 000 A+ 67 6 Start - DECO Candle. E LED./B/87/E/00-0V/FR /0 9086 0 700 No 80 000 A+ 0 0 Start - DECO Spherical. E LED./P/87/E/00-0V/FR /6 9086 0 700 No 80 000 A+ 8 6. E7 LED./P/87/E7/00-0V/FR /6 9086 0 700 No 80 000 A+ 78 6 Smart - CROWN DECO Candle B LEDD/P/87/B/0-0V/FR /6 900 70 700 Yes 0 80 0 000 A+ 76 0 E LEDD/P/87/E/0-0V/CLS /6 9006 70 700 Yes 60 80 0 000 A+ 76 0 E LEDD/P/87/E/0-0V/FR /6 9007 70 700 Yes 0 80 0 000 A+ 76 0 E7 LEDD/P/87/E7/0-0V/CLS /6 9008 70 700 Yes 60 80 0 000 A+ 76 0 E7 LEDD/P/87/E7/0-0V/FR /6 9009 70 700 Yes 0 80 0 000 A+ 76 0 6 0 E LED6D/P/87/E/0-0V/CLS /6 9006 70 700 Yes 60 80 0 000 A+ 90 0 6 0 E LED6D/P/87/E/0-0V/FR /6 9006 70 700 Yes 0 80 0 000 A+ 90 0 6 0 E7 LED6D/P/87/E7/0-0V/CLS /6 9006 70 700 Yes 60 80 0 000 A+ 90 0 6 0 E7 LED6D/P/87/E7/0-0V/FR /6 90066 70 700 Yes 0 80 0 000 A+ 90 0 6 0 E LED6D/B8/87/E/0-0V/FR /0 900 70 700 Yes 0 80 0 000 A+ 8 0 6 0 E7 LED6D/B8/87/E7/0-0V/CLS /0 900 70 700 Yes 60 80 0 000 A+ 8 0 6 0 E7 LED6D/B8/87/E7/0-0V/FR /0 900 70 700 Yes 0 80 0 000 A+ 8 0 Smart - CROWN DECO Spherical B LEDD/P/87/B/0-0V/FR /6 900 70 700 Yes 0 80 0 000 A+ 76 0 E LEDD/P/87/E/0-0V/CLS /6 9006 70 700 Yes 60 80 0 000 A+ 76 0 E LEDD/P/87/E/0-0V/FR /6 9007 70 700 Yes 0 80 0 000 A+ 76 0 E7 LEDD/P/87/E7/0-0V/CLS /6 9008 70 700 Yes 60 80 0 000 A+ 76 0 E7 LEDD/P/87/E7/0-0V/FR /6 9009 70 700 Yes 0 80 0 000 A+ 76 0 6 0 E LED6D/P/87/E/0-0V/CLS /6 9006 70 700 Yes 60 80 0 000 A+ 90 0 6 0 E LED6D/P/87/E/0-0V/FR /6 9006 70 700 Yes 0 80 0 000 A+ 90 0 6 0 E7 LED6D/P/87/E7/0-0V/CLS /6 9006 70 700 Yes 60 80 0 000 A+ 90 0 6 0 E7 LED6D/P/87/E7/0-0V/FR /6 90066 70 700 Yes 0 80 0 000 A+ 90 0 8 9 8 9 0 - - explanation For further information check the glossary LED 7 A60 8 6 00-0V E7 F Identifies Lamp wattage Identifies the lamp type CRI CCT Voltage Identifies the cap type Identifies the finish of the lamp F=FR=Frosted C=CLS=Clear 6 7 8 9 0 8 9
LED Retrofit LED Retrofit Solutions / LED Lamps LED Retrofit Solutions / LED Lamps Watt Replacement Nominal lumens Dimming ability LED Retrofit Beam Angle ( ) Rated life L70/B0 (h) Watt Replacement Dimming ability Beam Angle ( ) Rated life L70/B0 (h) efficiency class () Smart - CAPSULE G/G9 Smart - MR6 6 6 6 7 8 6 6 6 6 6.6 G LED.6/G/87/V/BL /0 9096 0 700 No 0 80 000 A++ 8 0. 0 G9 LED./G9/87/0-0V/BL /0 9097 00 700 No 0 80 000 A++ 8 0 Smart - PYGMY.6 E LED.6/T/87/00-0V/E/F 9098 0 700 No 80 000 A++ 9 0.6 E LED.6/T/86/00-0V/E/F 9097 0 600 No 80 000 A++ 9 00 Start - GU0 & E 0 E LED/R0/87//E/00-0V//BX/8 8609 0 700 No 80 000 A++ 0 76 8 GU0 LED/GU0/87/00-0V//BX /8 908 0 700 No 80 000 A++ 0 8 GU0 LED/GU0/87/00-0V//TWBX 9066 0 700 No 80 000 A++ 0 GU0 LED/GU0/80/00-0V//BX /8 9089 0 000 No 80 000 A++ 0 8 GU0 LED/GU0/80/00-0V//BX /8 9088 0 000 No 80 000 A++ 0 8. 0 GU0 LED./GU0/87/00-0V//BX /8 9087 700 No 80 000 A+ 0 8. 0 GU0 LED./GU0/80/00-0V//BX /8 9090 60 000 No 80 000 A+ 0 8. 0 GU0 LED./GU0/80/00-0V//BX /8 90 6 000 No 80 000 A++ 0 8 GU0 LED/GU0/87/00-0V//BL /8 908 0 700 No 80 000 A++ 0 8. 0 GU0 LED./GU0/87/00-0V//BL /8 9086 700 No 80 000 A++ 0 8 Smart - GU0 & E/E7. GU0 LED.D/GU0G/87/0-0V//BX /8 86* 0 700 Yes 80 000 A+ 0 8. GU0 LED.D/GU0G/80/0-0V//BX /8 86* 0 000 Yes 80 000 A+ 0 8. GU0 LED.D/GU0G/80/0-0V//BX /8 86* 60 000 Yes 80 000 A+ 0 8. 0 E LED.D/R0G/87/E/0-0V/BX/8 868 0 700 Yes 80 000 A+ 0 76 8. 0 E7 LED.D/P6G/87/E7/00-0V/BX/8 ES 9006 0 700 Yes 80 000 A+ 0 76 8. 0 GU0 LED.D/GU0G/87/0-0V//BX /8 869 60 700 Yes 80 000 A+ 0 8. 0 GU0 LED.D/GU0G/80/0-0V//BX /8 860 70 000 Yes 80 000 A+ 0 8. 0 GU0 LED.D/GU0G/80/0-0V//BX /8 86 00 000 Yes 80 000 A+ 0 8. GU0 LED.D/GU0G/87/0-0V//BL /8 867* 0 700 Yes 80 000 A+ 0 8. 0 GU0 LED.D/GU0G/87/0-0V//BL /8 86 60 700 Yes 80 000 A+ 0 8 * Will be discontinued from Q 06. MR6 LED./MR6/87/V/GU./WFL BX /8 908 80 700 No 80 000 A+ 0 7. 8. MR6 LED./MR6/80/V/GU./WFL BX /8 908 00 000 No 80 000 A+ 0 7. 8. MR6 LED./MR6/80/V/GU./WFL BX /8 908 0 000 No 80 000 A+ 0 7. 8 7 0 MR6 LED7/MR6/87/V/GU./WFL BX /8 908 00 700 No 80 000 A+ 0 7. 8 7 0 MR6 LED7/MR6/80/V/GU./WFL BX /8 908 0 000 No 80 000 A+ 0 7. 8 7 0 MR6 LED7/MR6/80/V/GU./WFL BX /8 9086 0 000 No 80 000 A+ 0 7. 8 Precise - MR6 7 MR6 LED7D/MR6GD/87/V/ BX/8 86* 70 700 Yes 80 000 A 0 8 7 MR6 LED7D/MR6GD/87/V/ BX/8 869* 70 700 Yes 80 000 A 0 8 7 MR6 LED7D/MR6GD/80/V/ BX/8 860* 90 000 Yes 8 000 A 0 8 7 MR6 LED7D/MR6GD/80/V/ BX/8 86* 90 000 Yes 8 000 A 0 8 7 MR6 LED7D/MR6GD/80/V/ BX/8 867* 0 000 Yes 8 000 A 0 8 7 MR6 LED7D/MR6GD/80/V/ BX/8 86* 0 000 Yes 8 000 A 0 8 7 0 MR6 LED7XD/MR6DG/87/V/ BX /8 9096 70 700 Yes 80 000 A+ 0. 8 7 0 MR6 LED7XD/MR6DG/87/V/ BX /8 907 00 700 Yes 80 000 A+ 0. 8 7 0 MR6 LED7XD/MR6GD/80/V/ BX/8 908 90 000 Yes 80 000 A+ 0. 8 7 0 MR6 LED7XD/MR6DG/80/V/ BX /8 907 0 000 Yes 80 000 A+ 0. 8 7 0 MR6 LED7XD/MR6DG/80/V/ BX /8 907 70 000 Yes 80 000 A+ 0. 8 * Will be discontinued from Q 06 Precise - PAR0/0 7 60 E7 LED7D/R6G/97/0-0V//E7 BX /6 906 80 700 Yes 90 0 000 A 6 9 6 7 60 E7 LED7D/R6G/90/0-0V//E7 BX /6 906 0 000 Yes 90 0 000 A 6 9 6 7 E7 LEDD/P0SG/97/0-0V//E7BX/6 9066 70 700 Yes 90 0 000 A 9 97 6 7 E7 LEDD/P0SG/90/0-0V//E7BX/6 9067 70 000 Yes 90 0 000 A 9 97 6 Smart - PAR8 8 0 E7 LED8/P8/87/90-0V//E7 BX /6 87* 00 700 No 8 0 000 A+ 6 0 E7 LED/PAR8G/80/90-0/E7/WFL BX /6 90 00 700 No 0 8 000 A+ 6 9 9 9 0 0 0 0 6 Precise - GU0 * Will be discontinued from Q 06 6 6 6 6 6 6 6 0 GU0 LED6D/GU0G/97/0-0V/FL BX /0H PR 9096 00 700 Yes 90 0 000 A+ 0. 0 6 0 GU0 LED6D/GU0G/97/0-0V/WFL BX /0H PR 909 00 700 Yes 90 0 000 A+ 0. 0 6 0 GU0 LED6D/GU0G/90/0-0V/FL BX /0H PR 909 0 000 Yes 90 0 000 A+ 0. 0 6 0 GU0 LED6D/GU0G/90/0-0V/WFL BX /0H PR 906 0 000 Yes 90 0 000 A+ 0. 0 6 0 GU0 LED6D/GU0G/90/0-0V/FL BX /0H PR 90 0 000 Yes 90 0 000 A+ 0. 0 6 0 GU0 LED6D/GU0G/90/0-0V/WFL BX /0H PR 90 0 000 Yes 90 0 000 A+ 0. 0 Smart - R 7 G LED/R/87/V/G/ BX /0 0 700 700 No 80 0 000 A 9 0 7 G LED/R/80/V/G/ BX /0 70 000 No 80 0 000 A 9 0 7 G LEDD/RG/87/V/G/ BX /0 90778 70 700 Yes 80 000 A 7 0 7 G LEDD/RG/80/V/G/ BX /0 90777 70 000 Yes 80 000 A 7 0 00 G LEDD/RG/87/V/G/ BX /0 9079 900 700 Yes 80 000 A 7 0 00 G LEDD/RG/80/V/G/ BX /0 9070 900 000 Yes 80 000 A 7 0 6 6 6 6 6 7 8 9 0 6 0
LED Retrofit LED Retrofit Solutions / LED Tubes LED Retrofit Solutions / LED Tubes LED Retrofit Beam Angle ( ) Rated life L70 (h) LED T8 Glass LED T8 Premium Universal Beam Angle ( ) Rated life L70 (h) 8 00 00-77 G LED 8/T8 PPU ft/80 90778 9 000 80< 0 000 8 8 A+ 0 8 00 00-77 G LED 8/T8 PPU ft/80 90780 60 000 80< 0 000 8 8 A+ 0 8 00 00-77 G LED 8/T8 PPU ft/86 90779 60 600 80< 0 000 8 8 A+ 0 LED T8 Basic 8 600 00-0 G LED 8/T8 BP ft/80 9098 700 000 0 80< 0 000 8 8 A+ 8 600 00-0 G LED 8/T8 BP ft/80 909 800 000 0 80< 0 000 8 8 A+ 8 600 00-0 G LED 8/T8 BP ft/86 9096 800 600 0 80< 0 000 8 8 A+ 0 600 00-0 G LED 0/T8 BP ft/80 9096 90 000 0 80< 0 000 8 0 A+ 0 600 00-0 G LED 0/T8 BP ft/80 9097 00 000 0 80< 0 000 8 0 A+ 0 600 00-0 G LED 0/T8 BP ft/86 900 00 600 0 80< 0 000 8 0 A+ 6 00 00-0 G LED 6/T8 BP ft/80 900 0 000 0 80< 0 000 8 6 A+ 6 00 00-0 G LED 6/T8 BP ft/80 900 600 000 0 80< 0 000 8 6 A+ 6 00 00-0 G LED 6/T8 BP ft/86 900 600 600 0 80< 0 000 8 6 A+ 0 00 00-0 G LED 0/T8 BP ft/80 900 80 000 0 80< 0 000 8 0 A+ 0 00 00-0 G LED 0/T8 BP ft/80 9000 00 000 0 80< 0 000 8 0 A+ 0 00 00-0 G LED 0/T8 BP ft/86 9099 00 600 0 80< 0 000 8 0 A+ 7 00 00-0 G LED 7/T8 BP ft/80* 9009 000 000 0 80< 0 000 8 7 A+ 7 00 00-0 G LED 7/T8 BP ft/80* 900 000 000 0 80< 0 000 8 7 A+ 7 00 00-0 G LED 7/T8 BP ft/86* 90 000 600 0 80< 0 000 8 7 A+ 7 00 00-0 G Rot LED 7/T8 BPR ft/80 90 000 000 0 80< 0 000 8 7 A+ 7 00 00-0 G Rot LED 7/T8 BPR ft/80 90 000 000 0 80< 0 000 8 7 A+ 7 00 00-0 G Rot LED 7/T8 BPR ft/86 90 000 600 0 80< 0 000 8 7 A+ 7 00 00-0 G LED 7/T8 VP ft/80* 9006 00 000 0 80< 0 000 8 7 A+ 7 00 00-0 G LED 7/T8 VP ft/80* 9007 700 000 0 80< 0 000 8 7 A+ 7 00 00-0 G LED 7/T8 VP ft/86* 9008 700 600 0 80< 0 000 8 7 A+ * Will be delisted 8 600 00-0 G LED 8/T8 VG ft/80 90 700 000 00 80< 0 000 8 8 A+ 8 600 00-0 G LED 8/T8 VG ft/80 90 800 000 00 80< 0 000 8 8 A+ 8 600 00-0 G LED 8/T8 VG ft/86 90 800 600 00 80< 0 000 8 8 A+ 0 600 00-0 G LED 0/T8 VG ft/80 90 90 000 00 80< 0 000 8 0 A+ 0 600 00-0 G LED 0/T8 VG ft/80 900 00 000 00 80< 0 000 8 0 A+ 0 600 00-0 G LED 0/T8 VG ft/86 90 00 600 00 80< 0 000 8 0 A+. 00 00-0 G LED./T8 VG ft/80 90 0 000 00 80< 0 000 8. A+. 00 00-0 G LED./T8 VG ft/80 90 60 000 00 80< 0 000 8. A+. 00 00-0 G LED./T8 VG ft/86 90 60 600 00 80< 0 000 8. A+ 8 00 00-0 G LED 8/T8 VG ft/80 909 80 000 00 80< 0 000 8 8 A+ 8 00 00-0 G LED 8/T8 VG ft/80 90 00 000 00 80< 0 000 8 8 A+ 8 00 00-0 G LED 8/T8 VG ft/86 900 00 600 00 80< 0 000 8 8 A+ 8 00 00-0 G LED 8/T8 VG ft/80 90 80 000 00 80< 0 000 8 8 A+ 0 8 00 00-0 G LED 8/T8 VG ft/80 90 00 000 00 80< 0 000 8 8 A+ 0 8 00 00-0 G LED 8/T8 VG ft/86 906 00 600 00 80< 0 000 8 8 A+ 0 7 00 00-0 G LED 7/T8 VG ft/80 90 00 000 00 80< 0 000 8 7 A+ 0 7 00 00-0 G LED 7/T8 VG ft/80 90 700 000 00 80< 0 000 8 7 A+ 0 7 00 00-0 G LED 7/T8 VG ft/86 906 700 600 00 80< 0 000 8 7 A+ 0 LED T8 Glass Rotatable 8 600 00-0 G Rot LED 8/T8 VGR ft/80 900 700 000 00 80< 0 000 8 8 A+ 8 600 00-0 G Rot LED 8/T8 VGR ft/80 909 800 000 00 80< 0 000 8 8 A+ 8 600 00-0 G Rot LED 8/T8 VGR ft/86 907 800 600 00 80< 0 000 8 8 A+ 0 600 00-0 G Rot LED 0/T8 VGR ft/80 90 90 000 00 80< 0 000 8 0 A+ 0 600 00-0 G Rot LED 0/T8 VGR ft/80 90 00 000 00 80< 0 000 8 0 A+ 0 600 00-0 G Rot LED 0/T8 VGR ft/86 90 00 600 00 80< 0 000 8 0 A+. 00 00-0 G Rot LED./T8 VGR ft/80 90 0 000 00 80< 0 000 8. A+. 00 00-0 G Rot LED./T8 VGR ft/80 90 60 000 00 80< 0 000 8. A+. 00 00-0 G Rot LED./T8 VGR ft/86 90 60 600 00 80< 0 000 8. A+ 8 00 00-0 G Rot LED 8/T8 VGR ft/80 906 80 000 00 80< 0 000 8 8 A+ 8 00 00-0 G Rot LED 8/T8 VGR ft/80 907 00 000 00 80< 0 000 8 8 A+ 8 00 00-0 G Rot LED 8/T8 VGR ft/86 908 00 600 00 80< 0 000 8 8 A+ 7 00 00-0 G Rot LED 7/T8 VGR ft/80 90 000 000 00 80< 0 000 8 7 A+ 0 7 00 00-0 G Rot LED 7/T8 VGR ft/80 906 000 000 00 80< 0 000 8 7 A+ 0 7 00 00-0 G Rot LED 7/T8 VGR ft/86 90 000 600 00 80< 0 000 8 7 A+ 0
LED Retrofit LED Retrofit Solutions / LED Plug-in Burning Position Beam Angle ( ) Rated life L70 (h) LED Indoor LED Pin Plug-in *. Horizontal Gq- LED./Gq-/P/H/87 GE BX/6 9098 0 700 00 x 7 80< 0 000. A+ 6. Horizontal Gq- LED./Gq-/P/H/80 GE BX/6 90986 90 000 00 x 7 80< 0 000. A+ 6. Horizontal Gq- LED./Gq-/P/H/80 GE BX/6 90987 00 000 00 x 7 80< 0 000. A+ 6. Horizontal Gq- LED./Gq-/P/H/86 GE BX/6 90988 0 600 00 x 7 80< 0 000. A+ 6. Vertical Gq- LED./Gq-/P/V/87 GE BX/6 90 0 700 87 80< 0 000 9. A+ 6. Vertical Gq- LED./Gq-/P/V/80 GE BX/6 909 90 000 87 80< 0 000 9. A+ 6. Vertical Gq- LED./Gq-/P/V/80 GE BX/6 900 00 000 87 80< 0 000 9. A+ 6. Vertical Gq- LED./Gq-/P/V/86 GE BX/6 9009 0 600 87 80< 0 000 9. A+ 6 * Lamp can t be operated directly from Mains voltage, an electronic ballast is needed. Visit this website for list of ballasts tested and approved for compatibility: www.gelighting.com/ledplugin-compatibility LED Indoor Solutions
LED Indoor Solutions LED Indoor Ambient Ambient lighting sets the mood, creating a comfortable environment in which to work, shop, dine, relax and more. We offer LED systems to suit all requirements, including the following ranges: GE Lumination BT LED Panel Easy installation into exposed T ceilings Combines brilliant aesthetics with space-filling light Dali Dimmable easily integrates into light controls Up to 0 LPW high efficiency Long life 0 000h @ L80 Feature Feature or accent lighting creates contrast, defines shape and guides the eye, making it key to the success of any lighting system. GE LED Eco Downlights Choice of sizes, lumen packages and CCTs Over 0% energy saving vs traditional lighting Ideal for accent light in retail applications LED Indoor GE LED NB000 Simple and elegant interior light fitting Integrated light module with dedicated optic Contemporary luminaire ranges for wall and ceiling mounting Integral emergency option Long life 0 000h @ L70 Arhitectural We offer LED products designed to meet the performance, efficiency and aesthetic requirements of specific architectural applications. Architectural LED Lighting Dramatic architectural lighting for indoor and outdoor use Innovative solutions with up to 0 000 hours of reliable light Functional Our functional ranges open up the benefits of LED long life, low energy costs, bright white light to applications such as retail warehousing, depots and industrial units. GE Albeo LED Direct replacement for HID and LFL Lamps in high bay applications attractive form factor with Flexible Modular Design GE Lumination IS LED Sleek, streamlined and designed for standalone use or continuous rows, these innovative luminaires deliver a clean, modern look Signage Signage LED Lighting Innovative solutions for long-lasting, high impact signage Design flexibility for channel letters and cabinet signs GE Mariner LED Slim, waterproof Mariner fittings designed for use with T8 LED Tubes IP6 rated for protection against damp, dust and accidental damage GE NPP LED Traditional style batten luminaire designed for use with T8 LED Tubes ideal for industrial sites, retail units and other sites where low maintenance, energy efficiency and excellent colour rendition are important Refrigeration Display Lighting LED Refrigeration Display Lighting Bright, targeted lighting for retail freezer/chiller units costs up to 8% less than fluorescent LONG LIFE LOW ENERGY COSTS BRIGHT WHITE LIGHT 6 7
LED Indoor Solutions overview LED Indoor Tetra Contour Tetra AL0 LED Linear Wall Wash System LED Indoor LED NB000 Lumination LED Luminaire BT-Series LED Accent Tetra PowerGrid Gen LED Soft Strip Ambient Architecture Albeo LED Luminaire ABV series LED Lumination IS LED Mariner TETRA minimax TETRA MAX TETRA PowerMAX TETRA Power Strip LED NPP TETRA TETRA TETRA TETRA ministrip EdgeStrip Contour LineFit Functional Signage LED Eco Downlight RH0 RV RV60 Immersion Elite Feature Refrigeration Display Lighting 8 9
LED Indoor Solutions / Ambient LED Indoor Solutions / Functional LED Indoor Controls Modules IP System Efficiency (lm/w) Optics Dimensions Ambient Temperature Weight (kg) Emergeny Lighitng Dimensions 96 ABV7V8DNVST IHNS 9089 0 800 000-0V 79 000 0 0 diffused >80 96x8x -0 to + C A++.9 96 ABV7V8NVST IHNS 9089 0 6 000-0V 79 000 0 06 >80 96x8x -0 to + C A++.9 96 ABV7V89NVST IHNS 9089 0 770 000-0V 79 000 0 90 >80 96x8x -0 to + C A++.6 96 ABV7V8DNDST IHNS 9089 0 800 000 DALI 79 000 0 0 diffused >80 96x8x -0 to + C A++.9 96 ABV7V8NDST IHNS 9089 0 6 000 DALI 79 000 0 06 >80 96x8x -0 to + C A++.9 96 ABV7V89NDST IHNS 90896 0 770 000 DALI 79 000 0 90 >80 96x8x -0 to + C A++.9 9 ABV7V8DNVST IHNS 90897 600 000-0V 79 000 0 0 diffused >80 96x76x -0 to + C A++.6 9 ABV7V8NVST IHNS 90898 0 0 000-0V 79 000 0 06 >80 96x76x -0 to + C A++.9 9 ABV7V89NVST IHNS 90899 0 000-0V 79 000 0 90 >80 96x76x -0 to + C A++.9 9 ABV7V8DNDST IHNS 90900 600 000 DALI 79 000 0 0 diffused >80 96x76x -0 to + C A++.9 9 ABV7V8NDST IHNS 9090 0 0 000 DALI 79 000 0 06 >80 96x76x -0 to + C A++.6 9 ABV7V89NDST IHNS 9090 0 000 DALI 79 000 0 90 >80 96x76x -0 to + C A++.9 LED NB000 8 BW7FWOPL 998 60 0 000 000 No ø6*. BW7FWOPL 999 00 0 000 000 No ø6*. BW7FEMWOPL 990 00 0 000 000 Yes ø6* 7 BW7FWOPL 99 00 0 000 000 No ø6* 8 BW7FWOPL 996 700 0 000 000 No ø6*. BW7FWOPL 997 00 0 000 000 No ø6*. BW7FEMWOPL 998 00 0 000 000 Yes ø6* 7 BW7FWOPL 999 00 0 000 000 No ø6* Lumination LED Luminaire BT-Series BT7AAPWHTE IHNS 90086 600 0 000 000 Static 0 9x9x no BT7AADWHTE IHNS 90087 600 0 000 000 DALI 0 9x9x no BT7CAPWHTE IHNS 909 00 0 000 000 Static 0 9x9x no BT7CADWHTE IHNS 909 00 0 000 000 DALI 0 9x9x no 0 BT7AAPWHTEEM IHNS 900 600 0 000 000 Static 0 9x9x yes 0 BT7AADWHTEEM IHNS 900 600 0 000 000 DALI 0 9x9x yes LED Indoor Thomas Cook UK GE SOLUTIONS: Lumination TM LED Luminaires Albeo LED Luminaire ABV series Controls IP Dimensions Emergency Lighting LED Lumination IS Driver Length Rated life L8 (h) IP System Efficiency (lm/w) Emergency version Operating Temperature Range ( C) IS7AMDSLVR IHNS 90 900 00 DALI 00 7 000 0 NO >8-0 to + 60x69x6 A++ IS7AMVSLVR IHNS 90 900 00-0V 00 7 000 0 NO >8-0 to + 60x69x6 A++ IS7AMDSLVR IHNS 906 900 000 DALI 00 7 000 0 8 NO >8-0 to + 60x69x6 A++ IS7AMVSLVR IHNS 907 900 000-0V 00 7 000 0 8 NO >8-0 to + 60x69x6 A++ IS7BMDSLVR IHNS 908 800 00 DALI 00 7 000 0 0 NO >8-0 to + 60x69x6 A++ IS7BMVSLVR IHNS 909 800 00-0V 00 7 000 0 0 NO >8-0 to + 60x69x6 A++ IS7BMDSLVR IHNS 900 000 000 DALI 00 7 000 0 6 NO >8-0 to + 60x69x6 A++ IS7BMVSLVR IHNS 906 000 000-0V 00 7 000 0 6 NO >8-0 to + 60x69x6 A++ 9 IS7AMVSLVREL IHNS 907 900 00-0V 00 7 000 0 0 YES >8-0 to + 60x69x6 A++ 9 IS7AMVSLVREL IHNS 90 900 000-0V 00 7 000 0 06 YES >8-0 to + 60x69x6 A++ 9 IS7AMDSLVREL IHNS 9077 900 00 DALI 00 7 000 0 0 YES >8-0 to + 60x69x6 A++ 9 IS7AMDSLVREL IHNS 9078 900 000 DALI 00 7 000 0 06 YES >8-0 to + 60x69x6 A++ 8 IS7BMVSLVREL IHNS 908 800 00-0V 00 7 000 0 0 YES >8-0 to + 60x69x6 A++ 8 IS7BMVSLVREL IHNS 908 000 000-0V 00 7 000 0 06 YES >8-0 to + 60x69x6 A++ 8 IS7BMDSLVREL IHNS 908 800 00 DALI 00 7 000 0 0 YES >8-0 to + 60x69x6 A++ 8 IS7BMDSLVREL IHNS 9086 000 000 DALI 00 7 000 0 06 YES >8-0 to + 60x69x6 A++ Dimensions 0
LED Indoor Solutions / Functional LED Indoor Solutions / Feature LED Indoor Dimensions IP Input Voltage (V) Weight (kg) Number of light sources Rated life L70/B0 (h) IP Nominal Size ( /mm) Operating temp. ( C) LEDs per module LED Indoor LED Mariner LED Eco Downlight LED NPP NL LED MARINER SINGLE 00MM GE 76* 70xx90 6 0-0.6 NL LED MARINER TWIN 00MM GE 76* 70xx90 6 0-0.7 NL LED MARINER SINGLE 00MM GE 766* 70xx90 6 0-0 NL LED MARINER TWIN 00MM GE 768* 70xx90 6 0-0. NL LED N-PACK NPP SINGLE 00MM GE * 70x 0 0-0.0 NL LED N-PACK NPP TWIN 00MM GE * 70x 0 0-0. NL LED N-PACK NPP SINGLE 00MM GE 867* 70x 0 0-0. NL LED N-PACK NPP TWIN 00MM GE 8669* 70x 0 0-0.8 7 DML8SP0 906 0 000 0 000 0 80 /00 0 to +0 7 A+ 7 DML8SP0 9066 600 000 0 000 0 80 /00 0 to +0 7 A++ 7 DML8SP6 9067 600 600 0 000 0 80 /00 0 to +0 7 A++ 0 DM6L0SP0 9068 70 000 0 000 0 80 6/0 0 to +0 0 A+ 0 DM6L0SP0 9060 800 000 0 000 0 80 6/0 0 to +0 0 A+ 0 DM6L0SP6 9076 800 600 0 000 0 80 6/0 0 to +0 0 A+ DM6LSP0 9076 900 000 0 000 0 80 6/0 0 to +0 A+ DM6LSP0 9076 000 000 0 000 0 80 6/0 0 to +0 A+ DM6LSP6 9069 000 600 0 000 0 80 6/0 0 to +0 A+ 8 DM8L8SP0 9076 0 000 0 000 0 80 8/00 0 to +0 8 A+ * Light sources not included. 8 DM8L8SP0 90767 00 000 0 000 0 80 8/00 0 to +0 8 A+ 8 DM8L8SP6 90766 00 600 0 000 0 80 8/00 0 to +0 8 A+ DM8LSP0 9076 800 000 0 000 0 80 8/00 0 to +0 A+ DM8LSP0 90768 000 000 0 000 0 80 8/00 0 to +0 A+ DM8LSP6 9077 000 600 0 000 0 80 8/00 0 to +0 A+ 0 DM8L0SP0 90770 0 000 0 000 0 80 8/00 0 to +0 A+ 0 DM8L0SP0 9077 00 000 0 000 0 80 8/00 0 to +0 A+ 0 DM8L0SP6 90769 00 600 0 000 0 80 8/00 0 to +0 A+
LED Indoor Solutions / Architecture LED Indoor Solutions / Architecture LED Indoor LED Indoor Tetra Contour Accessories Crowne Plaza Doha GE SOLUTIONS: Tetra Contour LED Single Pack Bulk Pack Bulk Colour Wavelength/ Colour Temp Viewing Angle (light engine) Viewing Angle (light engine w/ light guide) Lumens per metre (light engine) Lumens per metre (light engine w/ light guide) Watts per metre (light engine) Watts per metre (system) (kwh/000h) TETRA CONT REDLIGHT GUIDE 79 TETRA CONT REDLIGHT GUIDE END CAP 7 0 TETRA CONT REDLIGHT GUIDE CONNECTOR 70 0 TETRA CONT LIGHTGUIDE RED90 INSIDE CORNER 79 0 TETRA CONT LIGHTGUIDE RED90 OUTSIDE CORNER 796 0 TETRA CONT LIGHTGUIDE RED90 PLANAR CORNER 797 0 TETRA CONT GREENLIGHT GUIDE 7 TETRA CONT GREENLIGHT GUIDE END CAP 7 0 TETRA CONT GREENLIGHT GUIDE CONNECTOR 7 0 TETRA CONT LIGHTGUIDE GREEN90 INSIDE CORNER 70 0 TETRA CONT LIGHTGUIDE GREEN90 OUTSIDE CORNER 70 0 TETRA CONT LIGHTGUIDE GREEN90 PLANAR CORNER 70 0 TETRA CONT BLUELIGHT GUIDE 76 TETRA CONT BLUELIGHT GUIDE END CAP 7 0 TETRA CONT BLUELIGHT GUIDE CONNECTOR 77 0 TETRA CONT LIGHTGUIDE BLUE90 INSIDE CORNER 700 0 TETRA CONT LIGHTGUIDE BLUE90 OUTSIDE CORNER 70 0 TETRA CONT LIGHTGUIDE BLUE90 PLANAR CORNER 70 0 TETRACONTOUR LIGHT GUIDE - WHITE 7 TETRACONTOUR END CAP - WHITE 7 0 TETRACONTOUR CONNECTOR - WHITE 7 0 TETRA CONT LIGHTGUIDE WHITE 90 INSIDE CORNER 707 0 TETRA CONT LIGHTGUIDE WHITE 90 OUTSIDE CORNER 799 0 TETRACONT LIGHTGUIDE WHITE 90 PLANAR CORNER 7 0 TETRA CONTOUR CLEAR LIGHT GUIDE 686 MINIMAX SUPPLY WIRE,.m of 8 AWG Supply Wire (0.8mm ) 7 WEATHER BOX -PAINTABLE 79 0 TETRA CONTOUR SILICONE BEND-AID (Reusable) 06mm 77 TETRA CONTOUR LIGHT GUIDE MOUNTING CLIP 70 0 TETRA CONTOUR LIGHT ENGINE MOUNTING CLIP 798 0 6 7 8 9 0 LED Tetra Mariner Contour TETRA CONTOUR RED LED LIGHT ENGINE 600 78 Red 6nm 0 0 9 0.6. C.9 TETRA CONTOUR GREEN LED LIGHT ENGINE 60 78 6 Green nm 0 0 80 9.. B.06 TETRA CONTOUR BLUE LED LIGHT ENGINE 60 78 6 Blue 67nm 0 0 7 6 9.. N/A N/A TETRA CONTOUR LED LIGHT ENGINE 700K 688 787 6 White 700K 0 0 0 9.. B.06 TETRA CONTOUR LED LIGHT ENGINE 000K 689 788 6 White 000K 0 0 8 9 9.. B.06 TETRA CONTOUR LED LIGHT ENGINE 00K 69 789 6 White 00K 0 0 0 66 9.. B.06 TETRA CONTOUR LED LIGHT ENGINE 000K 690 790 6 White 000K 0 0 0 79 9.. B.06 TETRA CONTOUR LED LIGHT ENGINE 000K 69 79 6 White 000K 0 0 9.. B.06 TETRA CONTOUR LED LIGHT ENGINE 600K 69 786 6 White 600K 0 0 7 08 9.. B.06 Tetra Contour Drivers Full GEPS-00UGL-IP 678 0 LED Driver (VDC/00W) Input Voltage: 08-0VAC, Damp Location Rated GE80/MV/VT-C LED DRIVER 689 LED Driver (VDC/80W) Input Voltage: 90-0VAC, Damp Location Rated GE080/MV/DT-A LED DIM DRIVER 0-0V 790 0-0V Dimming LED Driver (VDC/80W): Input Voltage 90-0VAC,Damp Location Rated TETRA DIMMING MODULE 76 0-0V Dimming Module: use with non-dimming GE LED Driver 6 7 8 9 0
LED Indoor Solutions / Architecture LED Indoor Solutions / Architecture LED Indoor Fixture Colour Voltage Lens Type Lumens Per Fixture Lumens per Watt (kwh/000h) Full LED Indoor Tetra AL0 Tetra AL0 Drivers LPL-W8-060C-97 78867 White 0 700 9 60 clear 60 90 6.8 A 7.8 LPL-W09-090C-97 7888 White 0 700 9 90 clear 0. A.7 LPL-W8-0C-97 7887 White 0 700 9 0 clear 60 90 6.8 A 7.8 LPL-W8-0D-97 78878 White 0 700 9 0 soft 60 90 6.8 A 7.8 LPL-W09-0D-97 7886 White 0 700 9 0 soft 0. A.7 LPL-W8-060C-90 78868 White 0 000 9 60 clear 60 90 6.8 A 7.8 LPL-W09-060C-90 7886 White 0 000 9 60 clear 0. A.7 LPL-W8-090C-90 7887 White 0 000 9 90 clear 60 90 6.8 A 7.8 LPL-W09-090C-90 7889 White 0 000 9 90 clear 0. A.7 LPL-W8-0C-90 7887 White 0 000 9 0 clear 60 90 6.8 A 7.8 LPL-W09-0C-90 7886 White 0 000 9 0 clear 0. A.7 LPL-W8-0D-90 78879 White 0 000 9 0 soft 60 90 6.8 A 7.8 LPL-W09-0D-90 7886 White 0 000 9 0 soft 0. A.7 LPL-W8-060C-90 78870 White 0 000 9 60 clear 60 90 6.8 7 A 7.8 LPL-W09-060C-90 7887 White 0 000 9 60 clear 0. 7 A.7 LPL-W8-090C-90 7887 White 0 000 9 90 clear 60 90 6.8 7 A 7.8 LPL-W09-090C-90 78860 White 0 000 9 90 clear 0. 7 A.7 LPL-W8-0C-90 78877 White 0 000 9 0 clear 60 90 6.8 7 A 7.8 LPL-W09-0C-90 7886 White 0 000 9 0 clear 0. 7 A.7 LPL-W8-0D-90 78880 White 0 000 9 0 soft 60 90 6.8 7 A 7.8 LPL-W09-0D-90 78866 White 0 000 9 0 soft 0. 7 A.7 LPL-G09-060C-97 7888 Grey 0 700 9 60 clear 0. A.7 LPL-G09-0D-97 78890 Grey 0 700 9 0 soft 0. A.7 LPL-G8-090C-90 78897 Grey 0 000 9 90 clear 60 90 6.8 A 7.8 LPL-G09-090C-90 7888 Grey 0 000 9 90 clear 0. A.7 Tetra AL0 Accessories Full LC-6 7890 Leader Cable 9mm LC-0 78906 Leader Cable 08mm JC- 78907 Jumper Cable 0mm JC-7 78908 Jumper Cable 89mm MB-W 78909 0 Mounting Bracket White Angle MB-W0 7890 0 Mounting Bracket White 0 Angle MB-G 789 0 Mounting Bracket Grey Angle MB-G0 789 0 Mounting Bracket Grey 0 Angle LPL-MAGNET.MOUNTING.BRACKET (WHITE.0 68 0 0 degree magnetic mounting bracket LPL-MT W/SHIELD (6.00) 687 0 Mounting Track with a 6 degree light shield Wattage (W) GEPS-60UGL-IP 678 LED Driver V 60W GE00/G/VT-B 79 LED Driver V 0W TETRA DIMMING MODULE 76 0 TETRA DIMMING MODULE -V, 0-0V DC GE060/MV/DT-A LED DIM DRIVER 0-0V 790 0 LED Driver V 60W LED Linear Wall Wash System Input Voltage Lumens per Fixture (ft/m) LLWSOB00CV87VQTMWHTE 079 0 0V -77VAC/0Hz/60Hz 700 80 (67/0) 76 80 0 00 soft Cove IP0 LLWSOB00CV80VQTMWHTE 070 0 0V -77VAC/0Hz/60Hz 000 0 (0/9) 8 80 0 00 soft Cove IP0 LLWSOB00CV8VQTMWHTE 07 0 0V -77VAC/0Hz/60Hz 00 0 (0/9 8 80 0 00 soft Cove IP0 LLWSOB00CV80VQTMWHTE 077 0 0V -77VAC/0Hz/60Hz 000 0 (/6) 86 80 0 00 soft Cove IP0 LLWHOB00CV87VQTMWHTE 070 0 0V -77VAC/0Hz/60Hz 700 80 (67/0) 76 80 0 00 soft Cove IP0 LLWHOB00CV80VQTMWHTE 07 0 0V -77VAC/0Hz/60Hz 000 0 (0/9) 8 80 0 00 soft Cove IP0 LLWHOB00CV8VQTMWHTE 078 0 0V -77VAC/0Hz/60Hz 00 0 (0/9 8 80 0 00 soft Cove IP0 LLWHOB00CV80VQTMWHTE 076 0 0V -77VAC/0Hz/60Hz 000 0 (/6) 86 80 0 00 soft Cove IP0 LLWSOB00WW87VQTMWHTE 078 0 0V -77VAC/0Hz/60Hz 700 80 (67/0) 76 80 0 0 x 80 Wall Washer IP0 LLWSOB00WW80VQTMWHTE 0787 0 0V -77VAC/0Hz/60Hz 000 0 (0/9) 8 80 0 0 x 80 Wall Washer IP0 LLWSOB00WW8VQTMWHTE 0789 0 0V -77VAC/0Hz/60Hz 00 0 (0/9 8 80 0 0 x 80 Wall Washer IP0 LLWSOB00WW80VQTMWHTE 080 0 0V -77VAC/0Hz/60Hz 000 0 (/6) 86 80 0 0 x 80 Wall Washer IP0 8 LLWHOB00WW87VQTMWHTE 086 0 0V -77VAC/0Hz/60Hz 700 60 (67/07) 8 80 0 0 x 80 Wall Washer IP0 8 LLWHOB00WW80VQTMWHTE 086 0 0V -77VAC/0Hz/60Hz 000 70 (70/0) 9 80 0 0 x 80 Wall Washer IP0 8 LLWHOB00WW8VQTMWHTE 086 0 0V -77VAC/0Hz/60Hz 00 70 (70/0) 9 80 0 0 x 80 Wall Washer IP0 8 LLWHOB00WW80VQTMWHTE 0867 0 0V -77VAC/0Hz/60Hz 000 70 (7/7) 9 80 0 0 x 80 Wall Washer IP0 8 LLWSOB00GZ87VQTMWHTE 0868 0 0V -77VAC/0Hz/60Hz 700 60 (67/07) 8 80 0 x 80 Wall Grazer IP0 8 LLWSOB00GZ80VQTMWHTE 0869 0 0V -77VAC/0Hz/60Hz 000 70 (70/0) 9 80 0 x 80 Wall Grazer IP0 8 LLWSOB00GZ8VQTMWHTE 0888 0 0V -77VAC/0Hz/60Hz 00 70 (70/0) 9 80 0 x 80 Wall Grazer IP0 8 LLWSOB00GZ80VQTMWHTE 0889 0 0V -77VAC/0Hz/60Hz 000 70 (7/7) 9 80 0 x 80 Wall Grazer IP0 8 LLWHOB00GZ87VQTMWHTE 089 0 0V -77VAC/0Hz/60Hz 700 60 (67/07) 8 80 0 x 80 Wall Grazer IP0 8 LLWHOB00GZ80VQTMWHTE 089 0 0V -77VAC/0Hz/60Hz 000 70 (70/0) 9 80 0 x 80 Wall Grazer IP0 8 LLWHOB00GZ8VQTMWHTE 0899 0 0V -77VAC/0Hz/60Hz 00 70 (70/0) 9 80 0 x 80 Wall Grazer IP0 8 LLWHOB00GZ80VQTMWHTE 090 0 0V -77VAC/0Hz/60Hz 000 70 (7/7) 9 80 0 x 80 Wall Grazer IP0 Min. LPW Lens Type Application IP Rating 6 7
LED Indoor Solutions / Architecture LED Indoor Solutions / Architecture LED Indoor Full LED Linear Wall Wash System Accessories LWW-LC-0 090 GE LED Wall Washer, Leader Cable, 0 (08mm) With One End LWW-JC- 090 GE LED Wall Washer, Jumper Cable, (0mm) LWW-JC-8 090 GE LED Wall Washer, Jumper Cable, 8 (9mm) LWW-MT8/0 667 0 8 (9mm) Mounting Track 0/PK LED Indoor +/- Lens Strip W/ Module (per m) System W/ Module (per m) Lm/ Module LPW (System) LEC Budapest GE SOLUTIONS: Tetra PowerGrid LED Accent GEWWNL-7K-A 90 x 6.M 700K + 90/-0 0.78 ( 6.9) 0.97 ( 7.9) 8 8 GEWWNL-0K-A 90 x 6.M 000K + /- 0.78 ( 6.9) 0.97 ( 7.9) 8 86 GEWWNL-K-A 906 x 6.M 00K + /- 0.78 ( 6.9) 0.97 ( 7.9) 8 87 GEWWNL-0K-A 907 x 6.M 000K + /- 0.78 ( 6.9) 0.97 ( 7.9) 8 88 +/- Lens Strip W/ Module System W/ Module Lm/Module LPW (System) Modules/ Strip (kwh/000h) LED Accent Accessories Full Tetra PowerGrid Gen GEWWPGP6-7K-A 700K 908 x modules 700K + 90 /-0.W.7W 80 A+ 0.6 GEWWPGP6-0K-A 000K 90 x modules 000K + /-6.W.7W 0 8 A+ 0.6 GEWWPGP6-K-A 00K 90 x modules 00K + 0/-0.W.7W 8 A+ 0.6 GEWWPGP6-0K-A 000K 90 x modules 000K + /-.W.7W 0 8 A+ 0.6 MINIMAX SUPPLY WIRE 7 8 AWG Supply Wire ( 0.8mm ) (.m) 8-AWG IN-LINE CONN IDC 7 00 8- AWG In-Line Splice Connector (0.8-.08mm ) NL-MT8/0 69 Mounting Track 0 or 0 Angle, 9mm Full LED Accent Drivers Full GEDM-A 76 0 Tetra Dimming Module ( 0-0v) GEPS-60UGL-IP 678 0 LED Driver (VDC/60W): Input Voltage: 90-6VAC, Damp Location Rated GE00/G/VT-B 79 LED Driver (VDC 0W): Input voltage: 90-6VAC, Damp Location Rated GE060/MV/DT-A 790 0 0-0V Dimming LED Driver (VDC/ 60W): Input Voltage: 90-0VAC, Damp Location Rated Tetra PowerGrid Accessories MINIMAX SUPPLY WIRE 7 8 AWG Supply Wire ( 0.8mm ) (.m) 8-AWG IN-LINE CONN IDC 7 00 8- AWG In-Line Splice Connector (0.8-.08mm ) POWERGRID END CAP 76 00 0.-0.8mm Wire End s Tetra PowerGrid Drivers GEPS-00UGL-IP 678 0 LED Driver ( VDC/00W): Input Voltage: 08-0VAC, Damp Location Rated GE80/MV/VT-C 689 LED Driver ( VDC/80W): Input Voltage: 90-0VAC, Damp Location Rated GE080/MV/DT-A 0-0V 790 0 0-0V Dimming LED Driver ( VDC/80W) :Input Voltage 90-0VAC, Damp Location Rated 8 9
LED Indoor Solutions / Architecture LED Indoor Wattage (W/m) Lumen (lm/m) CCT (K) Pack Qty LED Indoor LSS0--7-60 90.8 70 700 0 m rolls per box LSS0--0-60 90.8 70 000 0 m rolls per box LSS0--7-60 90.8 70 700 0 m rolls per box LSS0--7-60 90 0 70 700 0 m rolls per box LSS0--0-60 906 0 80 000 0 m rolls per box LSS0--7-60 907 0 900 700 0 m rolls per box Wattage (W/m) Lumen (lm/m) CCT (K) Pack Qty LSS0--7-60-IP6 909.8 0 700 0 m rolls per box LSS0--7-60-IP6 908 0 700 700 0 m rolls per box LSS0--7-60-IP6 90.8 00 700 0 m rolls per box LSS0--7-60-IP6 900 0 800 700 0 m rolls per box LSS Connector strip to driver 907 00 LSS Connector strip to strip 907 00 Wattage LED Soft Strip - for Indoor usage LED Soft Strip - for Outdoor usage LED Soft Strip Drivers LEDCVEP 977 W LEDCVEPS 976 W LED60CVEP 9707 60W LED60CVEPS 9706 60W LED00CVEPS 979 00W LED0CVEMS 9779 0W LED00CVEPS 977 00W CentrePoint Budapest GE SOLUTIONS: Tetra TM Contour LED Lighting System 0
LED Indoor Solutions / Signage LED Indoor Solutions / Signage LED Indoor Lines Part Old Future/Current LED colour LEDs per Module Modules per Metre Viewing Angle ( ) Lumens per Module (Typical) kwh/000h Voltage Lines Part Old Future/Current LED colour LEDs per Module Modules per Metre Viewing Angle ( ) Lumens per Module (Typical) kwh/000h Voltage LED Indoor Tetra Range Tetra Tetra Range Range TETRA minimax mm min. stroke width 8mm min. depth TETRA minimax Wet mm min. stroke width 8mm min. depth TETRA minimax MS mm min. stroke width 8mm min. depth TETRA MAX 9mm min. stroke width 0mm min. height >0mm letter depth GEMM7-6 GEMM7- WHITE 700K 8 0 6 A++ 0.6 V GEMM7--CS 6 GEMM7--CS WHITE 700K 6.6 0 6 A++ 0.6 V GEMM0-69 GEMM0- WARM WHITE 000K 8 0 6 A++ 0.6 V GEMM0--CS 90 GEMM0--CS* WARM WHITE 000K 6.6 0 6 A++ 0.6 V GEMM- 60 GEMM- WARM WHITE 00K 8 0 A++ 0.6 V GEMM--CS 90 GEMM--CS* WARM WHITE 00K 6.6 0 A++ 0.6 V GEMM- 6 GEMM- WARM WHITE 00K 8 0 0 A++ 0.6 V GEMM--CS 90 GEMM--CS* WARM WHITE 00K 6.6 0 0 A++ 0.6 V GEMMRD- 989 GEMMRD-** RED 6nm 8 0 NA NA V GEMMBL- 9899 GEMMBL-** BLUE 67nm 8 0 8 NA NA V GEMMGL- 9890 GEMMGL-** GREEN 0nm 8 0 NA NA V GEMMPO- 989 GEMMPO-** ORANGE 606nm 8 0 9 NA NA V GEMM7-W 90 GEMM7-W WHITE 700K 8 0 6 A++ 0.6 V GEMM0-W 906 GEMM0-W WHITE 000K 8 0 6 A++ 0.6 V GEMM-W 907 GEMM-W WARM WHITE 00K 8 0 A++ 0.6 V GEMM-W 908 GEMM-W WARM WHITE 00K 8 0 0 A++ 0.6 V GEMMRD-W MINIMAX WET RED GEMMRD-W RED 6nm 8 0 0.8 NA NA V GEMMBL-W MINIMAX WET BLUE GEMMBL-W BLUE 7nm 8 0 7.6 NA NA V GEMMGL-W MINMAX WET GREEN GEMMGL-W GREEN 60nm 8 0 8.8 NA NA V GEMMPO-W MINIMAX WET ORANGE GEMMPO-W ORANGE 0nm 8 0. NA NA V GEMS7-97 GEMS7- WHITE 700K 8 Assym. 6 A++ 0. V GEMS0-98 GEMS0- WARM WHITE 000K 8 Assym. 6 A++ 0. V GEMS- 99 GEMS- WARM WHITE 00K 8 Assym. 8 A++ 0. V GEMS- 07 GEMS- WARM WHITE 00K 8 Assym. 8 A++ 0. V GEMSRD- MINIMAX MS LED MOD RED 88 GEMSRD- RED 6nm 8 Assym.. V GEMSBL- MINIMAX MS LED MOD BLUE 8 GEMSBL- BLUE 0nm 8 Assym.. V GEMSGL- MINIMAX MS LED MOD GREEN 87 GEMSGL- GREEN 67nm 8 Assym. 7.6 V GEMX7-68 GEMX7-* WHITE 700K 6.6 0 0.0 V GEMX0-69 GEMX0-** WARM WHITE 000K 6.6 0 A++ 0.0 V GEMX- 6 GEMX-* WARM WHITE 00K 6.6 0 7 A++ 0.0 V GEMX- 67 GEMX-* WARM WHITE 00K 6.6 0 A++ 0.0 V GEMXRD- 989 GEMXRD-* RED 6nm 6.6 0 NA NA V GEMXBL- 989 GEMXBL-* BLUE 67nm 6.6 0 0 NA NA V GEMXGL- 989 GEMXGL-* GREEN 0nm 6.6 0 0 A++ 0. V GEMXPO- 9896 GEMXPO-* ORANGE 606nm 6.6 0 NA NA V GEMXRC- 9897 GEMXRC-* RED-ORANGE 68nm 6.6 0 NA NA V GEMXYG- 9898 GEMXYG-* AMBER 6nm 6.6 0 NA NA V GEMXH7-68 GEMXH7-** WHITE 700K 6.6 0 8 A++ 0.79 V GEMXH0-60 GEMXH0-* WARM WHITE 000K 6.6 0 8 A++ 0.79 V GEMXH- 6 GEMXH-* WARM WHITE 00K 6.6 0 7 A++ 0.79 V GEMXH- 6 GEMXH-* WARM WHITE 00K 6.6 0 68 A++ 0.79 V GEMXHRD- 9899 GEMXHRD-** RED 6nm 6.6 0 6 NA NA V * While stock lasts. ** For current known projects. TETRA MAX Wet 9mm min. stroke width >0mm letter height 0mm min. depth TETRA MAX Wet 9mm min. stroke width >0mm letter height 0mm min. depth TETRA PowerMAX mm min. stroke width 0mm min. height >=9mm letter depth TETRA PowerMAX Wet mm min. stroke width >=9mm letter height 0mm min. depth TETRA Power Strip 7mm min. depth GEMX7-W 90086 GEMX7-W WHITE 700K 6.6 0 A++ 0.0 V GEMX0-W 9008 GEMX0-W WARM WHITE 000K 6.6 0 A++ 0.0 V GEMX-W 9007 GEMX-W WARM WHITE 00K 6.6 0 7 A++ 0.0 V GEMX-W 9007 GEMX-W WARM WHITE 00K 6.6 0 A++ 0.0 V GEMXRD-W MAX WET RED GEMXRD-W RED 6nm 6.6 0 NA NA V GEMXBL-W MAX WET BLUE GEMXBL-W BLUE 67nm 6.6 0 0 NA NA V GEMXGL-W MAX WET GREEN GEMXGL-W GREEN 0nm 6.6 0 8 NA NA V GEMXPO-W MAX WET ORANGE GEMXPO-W ORANGE 606nm 6.6 0 NA NA V GEMXRC-W MAX WET RED ORANGE GEMXRC-W RED-ORANGE 68nm 6.6 0 NA NA V GEMXYG-W MAX WET AMBER GEMXYG-W AMBER 89nm 6.6 0 NA NA V GEMXH7-W 900 GEMXH7-W WHITE 700K 6.6 0 8 A++ 0.79 V GEMXH0-W 9007 GEMXH0-W WARM WHITE 000K 6.6 0 8 A++ 0.79 V GEMXH-W 9007 GEMXH-W WARM WHITE 00K 6.6 0 7 A++ 0.79 V GEMXH-W 90060 GEMXH-W WARM WHITE 00K 6.6 0 68 A++ 0.79 V GEMXHRD-W MAX HO WET RED GEMXHRD-W RED 6nm 6.6 0 6 NA NA V GEPM7-66 GEPM7-* WHITE 700K 0 A++. V GEPM7--CS 66 GEPM7--CS** WHITE 700K. 0 A++. V GEPM0-668 GEPM0-* WARM WHITE 000K 0 A++. V GEPM0--CS 90 GEPM0--CS** WARM WHITE 000K. 0 A++. V GEPM- 669 GEPM-* WARM WHITE 00K 0 0 A++. V GEPM--CS 906 GEPM--CS* WARM WHITE 000K. 0 0 A++. V GEPM- 67 GEPM-* WARM WHITE 00K 0 09 A++. V GEPM--CS 907 GEPM--CS* WARM WHITE 000K. 0 09 A++. V GEPM7-W 9008 GEPM7-W WHITE 700K 0 A++. V GEPM0-W 9009 GEPM0-W WARM WHITE 000K 0 A++. V GEPM-W 9007 GEPM-W WARM WHITE 00K 0 0 A++. V GEPM-W 9006 GEPM-W WARM WHITE 00K 0 09 A++. V GESS7-960 GESS7-* WHITE 700K. 0 80 A++.6 V GESS7- PSTRIP SS 700K GESS7- WHITE 700K 7. 0 00 A++.6 V GESS0-96 GESS0-* WARM WHITE 000K. 0 80 A++.6 V GESS0- PSTRIP SS 000K GESS0- WARM WHITE 000K 7. 0 00 A++.6 V GESS- 96 GESS-* WARM WHITE 00K. 0 0 A++.6 V GESS- PSTRIP SS 00K GESS- WARM WHITE 00K 7. 0 00 A++.6 V GESS- 96 GESS-* WARM WHITE 00K. 0 0 A++.6 V GESS- PSTRIP SS 00K GESS- WARM WHITE 00K 7. 0 00 A++.6 V GESSH7-989 GESSH7-* WHITE 700K 8. 0 60 A+.99 V GESSH7-90 GESSH7- WHITE 700K. 0 68 A+.99 V GESSH0-989 GESSH0-* WARM WHITE 000K 8. 0 60 A+.99 V GESSH0-906 GESSH0- WARM WHITE 000K. 0 68 A+.99 V GESSH- 989 GESSH-* WARM WHITE 00K 8. 0 60 A+.99 V GESSH- 907 GESSH- WARM WHITE 00K. 0 A+.99 V GESSH- 989 GESSH-* WARM WHITE 00K 8. 0 60 A+.99 V GESSH- 908 GESSH- WARM WHITE 00K. 0 A+.99 V * While stock lasts. ** For current known projects.
LED Indoor Solutions / Signage LED Indoor Solutions / Signage LED Indoor Lines Part Old Future/Current LED colour LEDs per Module Modules per Metre Viewing Angle ( ) Lumens per Module (Typical) kwh/000h Voltage Tetra Tetra Range Range TETRA PowerStrip DS 7mm min. depth from face TETRA ministrip 76mm min. depth TETRA ministrip DS 76mm min. depth from face GEDS7-966 GEDS7-* WHITE 700K 0. 0 60 A++. V GEDS7- PSTRIP DS 700K GEDS7- WHITE 700K. 0 600 A++. V GEDS0-967 GEDS0- WARM WHITE 000K 0. 0 60 A++. V GEDS0- PSTRIP DS 000K GEDS0- WARM WHITE 000K. 0 600 A++. V GEDS- 968* GEDS-* WARM WHITE 00K 0. 0 0 A++. V GEDS- PSTRIP DS 00K GEDS-* WARM WHITE 00K. 0 600 A++. V GEDS- 969* GEDS-* WARM WHITE 00K 0. 0 0 A++. V GEDS- PSTRIP DS 00K GEDS-* WARM WHITE 00K. 0 600 A++. V GEDSH7-9896 GEDSH7-* WHITE 700K 6. 0 70 A+ 7. V GEDSH7-90 GEDSH7- WHITE 700K 8. 0 7 A+ 7. V GEDSH0-9897 GEDSH0-* WARM WHITE 000K 6. 0 70 A+ 7. V GEDSH0-90 GEDSH0- WARM WHITE 000K 8. 0 7 A+ 7. V GEDSH- 9898 GEDSH-* WARM WHITE 00K 6. 0 0 A+ 7. V GEDSH- 90 GEDSH- WARM WHITE 00K 8. 0 687 A+ 7. V GEDSH- 9899 GEDSH-* WARM WHITE 00K 6. 0 0 A+ 7. V GEDSH- 90 GEDSH- WARM WHITE 00K 8. 0 687 A+ 7. V GEWHBSP 987 GEWHBSP WHITE 700K. 0 96 A++. V GEWWBSP-0K 9878 GEWWBSP-0K* WARM WHITE 000K. 0 96 A++. V GEWWBSP-K 9877 GEWWBSP-K* WARM WHITE 00K. 0 7 A++. V GEWWBSP 9876 GEWWBSP* WARM WHITE 00K. 0 7 A++. V GEBSH7-9890 GEBSH7- WHITE 700K. 0 0 A++.6 V GEBSH0-989 GEBSH0-* WARM WHITE 000K. 0 0 A++.6 V GEBSH- 989 GEBSH-* WARM WHITE 00K. 0 90 A+.6 V GEBSH- 989 GEBSH-* WARM WHITE 00K. 0 90 A+.6 V GEWHBDP6 9879 GEWHBDP6 WHITE 700K 6. 0 9 A++. V GEWWBDP6-0K 988 GEWWBDP6-0K* WARM WHITE 000K 6. 0 9 A++. V GEWWBDP6-K 988 GEWWBDP6-K* WARM WHITE 00K 6. 0 A+. V GEWWBDP6 9880 GEWWBDP6* WARM WHITE 00K 6. 0 A+. V GEBDH7-989 GEBDH7- WHITE 700K 6. 0 0 A+.8 V GEBDH- 9896 WARM WHITE 00K 6. 0 80 A+.8 V GEBDH- 9897 WARM WHITE 00K 6. 0 80 A+.8 V Lines Part Old Future/Current LED colour Viewing Angle ( ) Rated Lumens kwh/000h Voltage Lines Part Old Future/Current LED colour LEDs per Module Modules per Metre Viewing Angle ( ) Lumens per Module (Typical) kwh/000h Voltage LED Indoor Tetra Tetra Range Range TETRA EdgeStrip 76mm min. depth TETRA Contour LS Straight Border Lighting mm neon replacement TETRA Contour Border & Accent Lighting mm neon replacement GEWHBIP 986 GEWHBIP WHITE 700K. 0 x 80 00 A++.6 V GEBI7- EDGESTRIP 700 GEBI7- WHITE 700K 7. 0 x 80 00 A++.6 V GEWWBIP-0K 988 GEWWBIP-0K WARM WHITE 000K. 0 x 80 00 A++.6 V GEBI0- EDGESTRIP 000 GEBI0- WARM WHITE 000K 7. 0 x 80 00 A++.6 V GEWWBIP-K 987 GEWWBIP-K WARM WHITE 00K. 0 x 80 0 A+.6 V GEBI- EDGESTRIP 00 GEBI- WARM WHITE 00K 7. 0 x 80 8 A++.6 V GEWWBIP 6 GEWWBIP WARM WHITE 00K. 0 x 80 0 A+.6 V GEBI- EDGESTRIP 00 GEBI- WARM WHITE 00K 7. 0 x 80 8 A++.6 V GEBIH7-9898 GEBIH7- WHITE 700K. 0 x 80 0 A+.9 V GEBIH7-9060 GEBIH7- WHITE 700 7. 7 x 80 0 A++.9 V GEBIH0-9899 GEBIH0- WARM WHITE 000K. 0 x 80 0 A+.9 V GEBIH0-906 GEBIH0- WARM WHITE 000 7. 7 x 80 0 A++.9 V GEBIH- 98960 GEBIH- WARM WHITE 00K. 0 x 80 0 A.9 V GEBIH- 906 GEBIH- WARM WHITE 00 7. 7 x 80 00 A++.9 V GEBIH- 9896 GEBIH- WARM WHITE 00K. 0 x 80 0 A.9 V GEBIH- 90 GEBIH- WARM WHITE 00 7. 7 x 80 00 A++.9 V GEXNLRD- 0 GEXNLRD- RED/RED 6nm 0 NA NA V GEXNLGL- 0 GEXNLGL- GREEN/GREEN nm 0 A.90 V GEXNLBL- 00 GEXNLBL- BLUE/BLUE 67nm 0 NA NA V GEXNL6-06 GEXNL6- WHITE/WHITE 600K 0 B.9 V GEXNL- 0 GEXNL- WARM WHITE/WHITE 00K 0 B.9 V GEXNRD- 966 GEXNRD- RED 6nm 0 NA NA V GEXNGL- 96 GEXNGL- GREEN nm 0 A.67 V GEXNBL- 96 GEXNBL- BLUE 67nm 0 NA NA V GEXNRC- 96 GEXNRC- RED/ORANGE 68nm 0 B.0 V GEXNYA- 97 GEXNYG- AMBER 89nm 0 NA NA V GEXN6-97 GEXN6- WHITE 600K 0 B.9 V GEXN- 97 GEXN- WARM WHITE 00K 0 B.9 V Tetra LineFit LED T8 Tetra LineFit LED T8 Tetra Range LineFit LED T8/ 00MM/76/V 90976 WHITE 600 00 G 7 x 00 TBA TBA V LineFit LED T8 /00MM/7/V 90977 WARM WHITE 00 00 G 7 x 00 TBA TBA V 6 6 6
LED Indoor Solutions / Signage LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Lines Part LED Colour Mounting Dimensions L W H Lumens per Module (Typical) kwh/000h Voltage LED Indoor Refrigeration RDL Display Range Lighting Range Frankfurt Airport Germany GE SOLUTIONS: Tetra PowerStrip LED lighting systems Lines TETRA LED Drivers Part Old Future/Current Number of Outputs Dimmable Y/N Tetra Tetra Range Range GEPS-U-EU PS VDC/W 90 GEPS-U-EU W x W N 08-0V 0/60Hz x 0 x 0. DRY / DAMP V Dimming Type Input Voltage Frequency Dimensions L W H GEPS-60U-GL 9897 GEPS-60U-GL 60W 60W N 0-77V 0/60Hz 0 0 DRY / DAMP V GEPSW-60M 9867 GEPSW-60M 60W 60W N 00-0V 0/60Hz 07 WET V GEPSD-60 986 GEPSD-60U 60W 60W Y 0-0V 00-77V 0/60Hz 0 0 DRY / DAMP V GEPS-U-EU PS VDC/W 90 GEPS-U-EU W XW N 08-0V 0/60Hz 0 0 DRY / DAMP V GEPSW-80M 98607 GEPSW-80M 80W 80W N 00-0V 0/60Hz 07 WET V GEPSD-80 9860 GEPSD-80U 80W 80W Y 0-0V 00-77V 0/60Hz 0 0 DRY / DAMP V GEPS-00U-GL 989 GEPS-00U-GL 00W 00W N 0-77V 0/60Hz 0 0 DRY / DAMP V GEPS-80U 9860 GEPS-80U 80W 90W N 00-77V 0/60Hz 9 6 0 DRY / DAMP V Location Rating Output Voltage RH0 Standard Horizontal GEMT00CAN-SB 6968 0 WHITE 000K Canopy 60 x x 600 A. V GEMT00CAN-SY 6968 WHITE 000K Canopy 60 x x 600 A. V GEMT00USL-SB 69690 0 WHITE 000K Undershelf 60 x x 0 A.96 V GEMT00USL-SY 69689 WHITE 000K Undershelf 60 x x 0 A.96 V GEMT0CAN-SB 6970 0 WHITE 00K Canopy 60 x x 78 A. V GEMT0CAN-SY 69709 WHITE 00K Canopy 60 x x 78 A. V GEMT0USL-SB 6976 0 WHITE 00K Undershelf 60 x x 0 A. V GEMT0USL-SY 697 WHITE 00K Undershelf 60 x x 0 A. V GEMT00CAN-SB 696 0 WHITE 000K Canopy 60 x x 77 A. V GEMT00CAN-SY 696 WHITE 000K Canopy 60 x x 77 A. V GEMT00USL-SB 6966 0 WHITE 000K Undershelf 60 x x 0 A+.96 V GEMT00USL-SY 6966 WHITE 000K Undershelf 60 x x 0 A+.96 V GEMT00CAN-SB 696 0 WHITE 000K Canopy 60 x x 77 A. V GEMT00CAN-SY 6960 WHITE 000K Canopy 60 x x 77 A. V GEMT00USL-SB 6967 0 WHITE 000K Undershelf 60 x x A+.96 V GEMT00USL-SY 6966 WHITE 000K Undershelf 60 x x A+.96 V GEMT060CAN-SB 69686 0 WHITE 000K Canopy 87 x x 900 A 7.9 V GEMT060CAN-SY 6968 WHITE 000K Canopy 87 x x 900 A 7.9 V GEMT060USL-SB 6969 0 WHITE 000K Undershelf 87 x x 0 A.9 V GEMT060USL-SY 6969 WHITE 000K Undershelf 87 x x 0 A.9 V GEMT06CAN-SB 697 0 WHITE 00K Canopy 87 x x 960 A 7.9 V GEMT06CAN-SY 697 WHITE 00K Canopy 87 x x 960 A 7.9 V GEMT06USL-SB 6978 0 WHITE 00K Undershelf 87 x x 8 A+.9 V GEMT06USL-SY 6977 WHITE 00K Undershelf 87 x x 8 A+.9 V GEMT060CAN-SB 6966 0 WHITE 000K Canopy 87 x x 00 A 7.9 V GEMT060CAN-SY 69660 WHITE 000K Canopy 87 x x 00 A 7.9 V GEMT060USL-SB 69667 0 WHITE 000K Undershelf 87 x x 0 A+.9 V GEMT060USL-SY 69666 WHITE 000K Undershelf 87 x x 0 A+.9 V GEMT060CAN-SB 696 0 WHITE 000K Canopy 87 x x 078 A 7.9 V GEMT060CAN-SY 696 WHITE 000K Canopy 87 x x 078 A 7.9 V GEMT060USL-SB 6969 0 WHITE 000K Undershelf 87 x x 7 A+.9 V GEMT060USL-SY 6968 WHITE 000K Undershelf 87 x x 7 A+.9 V GEMT080CAN-SB 69688 0 WHITE 000K Canopy x x 00 A.6 V GEMT080CAN-SY 69687 WHITE 000K Canopy x x 00 A.6 V GEMT080USL-SB 69696 0 WHITE 000K Undershelf x x 0 A 7.8 V GEMT080USL-SY 6969 WHITE 000K Undershelf x x 0 A 7.8 V GEMT08CAN-SB 697 0 WHITE 00K Canopy x x 00 A.6 V GEMT08CAN-SY 697 WHITE 00K Canopy x x 00 A.6 V GEMT08USL-SB 6970 0 WHITE 00K Undershelf x x A+ 7.8 V GEMT08USL-SY 6979 WHITE 00K Undershelf x x A+ 7.8 V GEMT080CAN-SB 6966 0 WHITE 000K Canopy x x 00 A.6 V GEMT080CAN-SY 6966 WHITE 000K Canopy x x 00 A.6 V GEMT080USL-SB 69669 0 WHITE 000K Undershelf x x 60 A+ 7.8 V GEMT080USL-SY 69668 WHITE 000K Undershelf x x 60 A+ 7.8 V 6 7
LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Lines Part LED Colour Mounting Dimensions L W H Lumens per Module (Typical) kwh/000h Voltage Lines Part LED Colour Mounting Dimensions L W H Lumens per Module (Typical) kwh/000h Voltage LED Indoor Refrigeration RDL Display Range Lighting Range Refrigeration RDL Display Range Lighting Range GEMT080CAN-SB 696 0 WHITE 000K Canopy x x 0 A.6 V RH0 Standard GEMT080CAN-SY 696 WHITE 000K Canopy x x 0 A.6 V Horizontal GEMT080USL-SB 696 0 WHITE 000K Undershelf x x 00 A+ 7.8 V GEMT080USL-SY 6960 WHITE 000K Undershelf x x 00 A+ 7.8 V RH0 00W Driver GEPS6000NCMUL-SY 689 7 x x8 V RH0 0W Driver GEPS600NCMUL-SY 689 7 x x8 V RH0 Mounting Clip GEMT000NCM-SY 697 pack of 7 x 6 x 0 RH0 Mounting Clip GEMT000NCM-SB 697 pack of 0 7 x 6 x 0 GEMT0CAN-SB 69698 0 WHITE 000K Canopy 60 x x 7 A. V GEMT0CAN-SY 69697 WHITE 000K Canopy 60 x x 7 A. V GEMT0USL-SB 6970 0 WHITE 000K Undershelf 60 x x 60 A.9 V GEMT0USL-SY 6970 WHITE 000K Undershelf 60 x x 60 A.9 V GEMT0CAN-SB 6967 0 WHITE 000K Canopy 60 x x 8 A. V GEMT0CAN-SY 69670 WHITE 000K Canopy 60 x x 8 A. V GEMT0USL-SB 69677 0 WHITE 000K Undershelf 60 x x 8 A.96 V GEMT0USL-SY 69676 WHITE 000K Undershelf 60 x x 8 A.96 V GEMT60CAN-SB 69700 0 WHITE 000K Canopy 890 x x 60 A 7.9 V GEMT60CAN-SY 69699 WHITE 000K Canopy 890 x x 60 A 7.9 V GEMT60USL-SB 69706 0 WHITE 000K Undershelf 890 x x A.9 V RH0 Premium GEMT60USL-SY 6970 WHITE 000K Undershelf 890 x x A.9 V Horizontal GEMT60CAN-SB 6967 0 WHITE 000K Canopy 890 x x 70 A 7.9 V GEMT60CAN-SY 6967 WHITE 000K Canopy 890 x x 70 A 7.9 V GEMT60USL-SB 69679 0 WHITE 000K Undershelf 890 x x 7 A.9 V GEMT60USL-SY 69678 WHITE 000K Undershelf 890 x x 7 A.9 V GEMT80CAN-SB 6970 0 WHITE 000K Canopy 60 x x 8 A.6 V GEMT80CAN-SY 6970 WHITE 000K Canopy 60 x x 8 A.6 V GEMT80USL-SB 69708 0 WHITE 000K Undershelf 60 x x 0 A 7.8 V GEMT80USL-SY 69707 WHITE 000K Undershelf 60 x x 0 A 7.8 V GEMT80CAN-SB 6967 0 WHITE 000K Canopy 60 x x 97 A.6 V GEMT80CAN-SY 6967 WHITE 000K Canopy 60 x x 97 A.6 V GEMT80USL-SB 6968 0 WHITE 000K Undershelf 60 x x 7 A 7.8 V GEMT80USL-SY 69680 WHITE 000K Undershelf 60 x x 7 A 7.8 V RH0 00W Driver GEPS6000NCMUL-SY 689 7 x x8 V RH0 0W Driver GEPS600NCMUL-SY 689 7 x x8 V RH0 Mounting Clip GEMT000NCM-SY 697 pack of 7 x 6 x 0 RH0 Mounting Clip GEMT000NCM-SB 697 pack of 0 7 x 6 x 0 RV Vertical GELTE600CTR-SB 6779 0 WHITE 000K Centre 98 x x 80 A.6 V GELTE600CTR-SY 6779 WHITE 000K Centre 98 x x 80 A.6 V GELTE600EDL-SB 67797 0 WHITE 000K Left 0 x 9 x 7 88 A+ 6.9 V GELTE600EDL-SY 6779 WHITE 000K Left 0 x 9 x 7 88 A+ 6.9 V GELTE600EDR-SB 67796 0 WHITE 000K Right 0 x 9 x 7 88 A+ 6.9 V GELTE600EDR-SY 6779 WHITE 000K Right 0 x 9 x 7 88 A+ 6.9 V GELTE600CTR-SB 67789 0 WHITE 000K Centre 98 x x 9 A+.6 V GELTE600CTR-SY 67786 WHITE 000K Centre 98 x x 9 A+.6 V GELTE600EDL-SB 6779 0 WHITE 000K Left 0 x 9 x 7 A+ 6.9 V GELTE600EDL-SY 67788 WHITE 000K Left 0 x 9 x 7 A+ 6.9 V GELTE600EDR-SB 67790 0 WHITE 000K Right 0 x 9 x 7 A+ 6.9 V GELTE600EDR-SY 67787 WHITE 000K Right 0 x 9 x 7 A+ 6.9 V GELTE700CTR-SB 67807 0 WHITE 000K Centre 76 x x 99 A.8 V GELTE700CTR-SY 6780 WHITE 000K Centre 76 x x 99 A.8 V GELTE700EDL-SB 67809 0 WHITE 000K Left 766 x 9 x 7 99 A+ 7.9 V GELTE700EDL-SY 67806 WHITE 000K Left 766 x 9 x 7 99 A+ 7.9 V GELTE700EDR-SB 67808 0 WHITE 000K Right 766 x 9 x 7 99 A+ 7.9 V GELTE700EDR-SY 6780 WHITE 000K Right 766 x 9 x 7 99 A+ 7.9 V GELTE700CTR-SB 6780 0 WHITE 000K Centre 76 x x 66 A+.8 V GELTE700CTR-SY 67798 WHITE 000K Centre 76 x x 66 A+.8 V GELTE700EDL-SB 6780 0 WHITE 000K Left 766 x 9 x 7 686 A+ 7.9 V GELTE700EDL-SY 67800 WHITE 000K Left 766 x 9 x 7 686 A+ 7.9 V GELTE700EDR-SB 6780 0 WHITE 000K Right 766 x 9 x 7 686 A+ 7.9 V GELTE700EDR-SY 67799 WHITE 000K Right 766 x 9 x 7 686 A+ 7.9 V RV Driver GEPS000NCMUL-SY 798 7 x x 7 V RV Wire Cover GE-CV-060CTR 798 pack of 0 x 6 x 0 RV60 Vertical GELT608CTR-SB 877 0 WHITE 00K Centre x 66 x 8 A. V GELT608CTR-SY 87 WHITE 00K Centre x 66 x 8 A. V GELT608EDL-SB 879 0 WHITE 00K Left x x 0 00 A+ 7.9 V GELT608EDL-SY 876 WHITE 00K Left x x 0 00 A+ 7.9 V GELT608EDR-SB 878 0 WHITE 00K Right x x 0 00 A+ 7.9 V GELT608EDR-SY 87 WHITE 00K Right x x 0 00 A+ 7.9 V GELT6080CTR-SB 87 0 WHITE 000K Centre x 66 x 8 A. V GELT6080CTR-SY 878 WHITE 000K Centre x 66 x 8 A. V GELT6080EDL-SB 87 0 WHITE 000K Left x x 0 A+ 7.9 V GELT6080EDL-SY 870 WHITE 000K Left x x 0 A+ 7.9 V GELT6080EDR-SB 87 0 WHITE 000K Right x x 0 A+ 7.9 V GELT6080EDR-SY 879 WHITE 000K Right x x 0 A+ 7.9 V GELT6080CTR-SB 87 0 WHITE 000K Centre x 66 x 896 A. V GELT6080CTR-SY 87 WHITE 000K Centre x 66 x 896 A. V GELT6080EDL-SB 877 0 WHITE 000K Left x x 0 9 A+ 7.9 V GELT6080EDL-SY 87 WHITE 000K Left x x 0 9 A+ 7.9 V GELT6080EDR-SB 876 0 WHITE 000K Right x x 0 9 A+ 7.9 V Picard France GE SOLUTIONS: Immersion TM RDL Solution 8 9
LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Lines Part LED Colour Mounting Dimensions L W H Lumens per Module (Typical) kwh/000h Voltage Lines Part Mounting Dimensions Length (Inches/mm) Light Output (lm) Lumens Per Watt Voltage LED Indoor Refrigeration Display Lighting Range Refrigeration RDL Display Range Lighting Range GELT6080EDR-SY 87 WHITE 000K Right x x 0 9 A+ 7.9 V GELT6060CTR-SB 87 0 WHITE 00K Centre x 66 x 908 A.9 V GELT6060CTR-SY 87 WHITE 00K Centre x 66 x 908 A.9 V GELT6060EDL-SB 876 0 WHITE 00K Left x x 0 6 A+ 7.70 V GELT6060EDL-SY 87 WHITE 00K Left x x 0 6 A+ 7.70 V GELT6060EDR-SB 87 0 WHITE 00K Right x x 0 6 A+ 7.70 V GELT6060EDR-SY 87 WHITE 00K Right x x 0 6 A+ 7.70 V GELT60600CTR-SB 8708 0 WHITE 000K Centre x 66 x 0 A.9 V GELT60600CTR-SY 870 WHITE 000K Centre x 66 x 0 A.9 V GELT60600EDL-SB 870 0 WHITE 000K Left x x 0 77 A+ 7.70 V GELT60600EDL-SY 8707 WHITE 000K Left x x 0 77 A+ 7.70 V GELT60600EDR-SB 8709 0 WHITE 000K Right x x 0 77 A+ 7.70 V GELT60600EDR-SY 8706 WHITE 000K Right x x 0 77 A+ 7.70 V GELT60600CTR-SB 870 0 WHITE 000K Centre x 66 x 00 A.9 V GELT60600CTR-SY 8699 WHITE 000K Centre x 66 x 00 A.9 V GELT60600EDL-SB 870 0 WHITE 000K Left x x 0 69 A+ 7.70 V GELT60600EDL-SY 870 WHITE 000K Left x x 0 69 A+ 7.70 V GELT60600EDR-SB 870 0 WHITE 000K Right x x 0 69 A+ 7.70 V RV60 Vertical GELT60600EDR-SY 8700 WHITE 000K Right x x 0 69 A+ 7.70 V GELT6067CTR-SB 879 0 WHITE 00K Centre 7 x 66 x 0 A 6.9 V GELT6067CTR-SY 876 WHITE 00K Centre 7 x 66 x 0 A 6.9 V GELT6067EDL-SB 87 0 WHITE 00K Left 7 x x 0 667 A 9.68 V GELT6067EDL-SY 878 WHITE 00K Left 7 x x 0 667 A 9.68 V GELT6067EDR-SB 870 0 WHITE 00K Right 7 x x 0 667 A 9.68 V GELT6067EDR-SY 877 WHITE 00K Right 7 x x 0 667 A 9.68 V GELT60670CTR-SB 878 0 WHITE 000K Centre 7 x 66 x A 6.9 V GELT60670CTR-SY 87 WHITE 000K Centre 7 x 66 x A 6.9 V GELT60670EDL-SB 87 0 WHITE 000K Left 7 x x 0 68 A 9.68 V GELT60670EDL-SY 877 WHITE 000K Left 7 x x 0 68 A 9.68 V GELT60670EDR-SB 87 0 WHITE 000K Right 7 x x 0 68 A 9.68 V GELT60670EDR-SY 876 WHITE 000K Right 7 x x 0 68 A 9.68 V GELT60670CTR-SB 87 0 WHITE 000K Centre 7 x 66 x 7 A 6.9 V GELT60670CTR-SY 877 WHITE 000K Centre 7 x 66 x 7 A 6.9 V GELT60670EDL-SB 87 0 WHITE 000K Left 7 x x 0 7 A+ 9.68 V GELT60670EDL-SY 87 WHITE 000K Left 7 x x 0 7 A+ 9.68 V GELT60670EDR-SB 87 0 WHITE 000K Right 7 x x 0 7 A+ 9.68 V GELT60670EDR-SY 870 WHITE 000K Right 7 x x 0 7 A+ 9.68 V RV60 00W Driver GEPS6000NCMUL-SY 689 7 x x 8 V RV60 0W Driver GEPS600NCMUL-SY 689 7 x x 8 V RV60 Wire Cover GE-CV-060CTR 798 pack of 0 x 6 x 0 Immersion TM Elite Freezer Door Eco ELVE8CS 908 7.9 00 Centre 8/9 899 80 V ELVE8RS 909.8 00 End Right 8/9 0 80 V ELVE8LS 900.8 00 End Left 8/9 0 80 V ELVE8CB 908 0 7.9 00 Centre 8/9 899 80 V ELVE8RB 908 0.8 00 End Right 8/9 0 80 V ELVE8LB 908 0.8 00 End Left 8/9 0 80 V ELVE80CS 908 7.9 000 Centre 8/9 9 80 V ELVE80RS 908.8 000 End Right 8/9 0 80 V ELVE80LS 9086.8 000 End Left 8/9 0 80 V ELVE80CB 9087 0 7.9 000 Centre 8/9 9 80 V ELVE80RB 9088 0.8 000 End Right 8/9 0 80 V ELVE80LB 9089 0.8 000 End Left 8/9 0 80 V ELVE80CS 900 7.9 000 Centre 8/9 96 80 V ELVE80RS 9006.8 000 End Right 8/9 8 80 V ELVE80LS 9007.8 000 End Left 8/9 8 80 V ELVE80CB 9008 0 7.9 000 Centre 8/9 96 80 V ELVE80RB 9009 0.8 000 End Right 8/9 8 80 V ELVE80LB 9000 0.8 000 End Left 8/9 8 80 V ELVE60CS 9090 0.08 00 Centre 60/ 80 V ELVE60RS 909.8 00 End Right 60/ 0 80 V ELVE60LS 909.8 00 End Left 60/ 0 80 V ELVE60CB 909 0 0.08 00 Centre 60/ 80 V ELVE60RB 909 0.8 00 End Right 60/ 0 80 V ELVE60LB 909 0.8 00 End Left 60/ 0 80 V ELVE600CS 90 0.08 000 Centre 60/ 0 80 V ELVE600RS 9086.8 000 End Right 60/ 0 80 V ELVE600LS 9097.8 000 End Left 60/ 0 80 V ELVE600CB 900 0 0.08 000 Centre 60/ 0 80 V ELVE600RB 9006 0.8 000 End Right 60/ 0 80 V ELVE600LB 9007 0.8 000 End Left 60/ 0 80 V ELVE600CS 9008 0.08 000 Centre 60/ 6 80 V ELVE600RS 9009.8 000 End Right 60/ 8 80 V ELVE600LS 900.8 000 End Left 60/ 8 80 V ELVE600CB 906 0 0.08 000 Centre 60/ 6 80 V ELVE600RB 907 0.8 000 End Right 60/ 8 80 V ELVE600LB 908 0.8 000 End Left 60/ 8 80 V ELVE67CS 9096 0.08 00 Centre 67/708 80 V ELVE67RS 9097 6.7 00 End Right 67/708 686 0 80 V ELVE67LS 9098 6.7 00 End Left 67/708 686 0 80 V ELVE67CB 9099 0 0.08 00 Centre 67/708 80 V 0
LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Lines Part Mounting Dimensions Length (Inches/mm) Light Output (lm) Lumens Per Watt Voltage Lines Part Mounting Dimensions Length (Inches/mm) Light Output (lm) Lumens Per Watt Voltage LED Indoor Refrigeration RDL Display Range Lighting Range Refrigeration RDL Display Range Lighting Range Immersion TM Elite Freezer Door Eco Immersion TM Elite Freezer Door Standard ELVE67RB 9000 0 6.7 00 End Right 67/708 686 0 80 V ELVE67LB 900 0 6.7 00 End Left 67/708 686 0 80 V ELVE670CS 900 0.08 000 Centre 67/708 0 80 V ELVE670RS 900 6.7 000 End Right 67/708 697 0 80 V ELVE670LS 900 6.7 000 End Left 67/708 697 0 80 V ELVE670CB 900 0 0.08 000 Centre 67/708 0 80 V ELVE670RB 9006 0 6.7 000 End Right 67/708 697 0 80 V ELVE670LB 9007 0 6.7 000 End Left 67/708 697 0 80 V ELVE670CS 900 0.08 000 Centre 67/708 6 80 V ELVE670RS 900 6.7 000 End Right 67/708 77 0 80 V ELVE670LS 900 6.7 000 End Left 67/708 77 0 80 V ELVE670CB 900 0 0.08 000 Centre 67/708 6 80 V ELVE670RB 900 0 6.7 000 End Right 67/708 77 0 80 V ELVE670LB 9006 0 6.7 000 End Left 67/708 77 0 80 V ELVS8CS 9008. 00 Centre 8/9 7 99 8 V ELVS8RS 9009 7.9 00 End Right 8/9 78 9 8 V ELVS8LS 900 7.9 00 End Left 8/9 78 9 8 V ELVS8CB 90 0. 00 Centre 8/9 7 99 8 V ELVS8RB 90 0 7.9 00 End Right 8/9 78 9 8 V ELVS8LB 90 0 7.9 00 End Left 8/9 78 9 8 V ELVS80CS 90. 000 Centre 8/9 7 00 8 V ELVS80RS 90 7.9 000 End Right 8/9 79 9 8 V ELVS80LS 906 7.9 000 End Left 8/9 79 9 8 V ELVS80CB 907 0. 000 Centre 8/9 7 00 8 V ELVS80RB 908 0 7.9 000 End Right 8/9 79 9 8 V ELVS80LB 909 0 7.9 000 End Left 8/9 79 9 8 V ELVS80CS 900. 000 Centre 8/9 07 8 V ELVS80RS 90 7.9 000 End Right 8/9 78 99 8 V ELVS80LS 90 7.9 000 End Left 8/9 78 99 8 V ELVS80CB 90 0. 000 Centre 8/9 07 8 V ELVS80RB 90 0 7.9 000 End Right 8/9 78 99 8 V ELVS80LB 90 0 7.9 000 End Left 8/9 78 99 8 V ELVS60CS 906 6.8 00 Centre 60/ 68 99 8 V ELVS60RS 907 0.6 00 End Right 60/ 97 9 8 V ELVS60LS 908 0.6 00 End Left 60/ 97 9 8 V ELVS60CB 909 0 6.8 00 Centre 60/ 68 99 8 V ELVS60RB 900 0 0.6 00 End Right 60/ 97 9 8 V ELVS60LB 90 0 0.6 00 End Left 60/ 97 9 8 V ELVS600CS 909 6.8 000 Centre 60/ 68 00 8 V ELVS600RS 900 0.6 000 End Right 60/ 97 9 8 V ELVS600LS 908 0.6 000 End Left 60/ 97 9 8 V ELVS600CB 908 0 6.8 000 Centre 60/ 68 00 8 V Immersion TM Elite Freezer Door Standard Immersion TM Elite Freezer Door Premium ELVS600RB 908 0 0.6 000 End Right 60/ 97 9 8 V ELVS600LB 908 0 0.6 000 End Left 60/ 97 9 8 V ELVS600CS 908 6.8 000 Centre 60/ 80 07 8 V ELVS600RS 9087 0.6 000 End Right 60/ 0 99 8 V ELVS600LS 9088 0.6 000 End Left 60/ 0 99 8 V ELVS600CB 9089 0 6.8 000 Centre 60/ 80 07 8 V ELVS600RB 9090 0 0.6 000 End Right 60/ 0 99 8 V ELVS600LB 909 0 0.6 000 End Left 60/ 0 99 8 V ELVS67CS 90 6.8 00 Centre 67/708 68 99 8 V ELVS67RS 90 0.6 00 End Right 67/708 97 9 8 V ELVS67LS 90 0.6 00 End Left 67/708 97 9 8 V ELVS67CB 90 0 6.8 00 Centre 67/708 68 99 8 V ELVS67RB 906 0 0.6 00 End Right 67/708 97 9 8 V ELVS67LB 907 0 0.6 00 End Left 67/708 97 9 8 V ELVS670CS 90069 6.8 000 Centre 67/708 68 00 8 V ELVS670CS 90069 6.8 000 Centre 67/708 68 00 8 V ELVS670RS 90070 0.6 000 End Right 67/708 97 9 8 V ELVS670LS 9007 0.6 000 End Left 67/708 97 9 8 V ELVS670CB 9007 0 6.8 000 Centre 67/708 68 00 8 V ELVS670RB 9007 0 0.6 000 End Right 67/708 97 9 8 V ELVS670LB 9007 0 0.6 000 End Left 67/708 97 9 8 V ELVS670CS 9007 6.8 000 Centre 67/708 80 07 8 V ELVS670RS 90076 0.6 000 End Right 67/708 0 99 8 V ELVS670LS 90077 0.6 000 End Left 67/708 0 99 8 V ELVS670CB 90078 0 6.8 000 Centre 67/708 80 07 8 V ELVS670RB 90079 0 0.6 000 End Right 67/708 0 99 8 V ELVS670LB 90080 0 0.6 000 End Left 67/708 0 99 8 V ELVP8CS 908 6.8 00 Centre 8/9 86 88 90 V ELVP8RS 909 0.08 00 End Right 8/9 8 80 90 V ELVP8LS 900 0.08 00 End Left 8/9 8 80 90 V ELVP8CB 90 0 6.8 00 Centre 8/9 86 88 90 V ELVP8RB 90 0 0.08 00 End Right 8/9 8 80 90 V ELVP8LB 90 0 0.08 00 End Left 8/9 8 80 90 V ELVP80CS 90 6.8 000 Centre 8/9 0 90 90 V ELVP80RS 90 0.08 000 End Right 8/9 8 8 90 V ELVP80LS 906 0.08 000 End Left 8/9 8 8 90 V ELVP80CB 907 0 6.8 000 Centre 8/9 0 90 90 V ELVP80RB 908 0 0.08 000 End Right 8/9 8 8 90 V ELVP80LB 909 0 0.08 000 End Left 8/9 8 8 90 V ELVP80CS 900 6.8 000 Centre 8/9 67 97 90 V ELVP80RS 90 0.08 000 End Right 8/9 89 89 90 V ELVP80LS 90 0.08 000 End Left 8/9 89 89 90 V
LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Lines Part Mounting Dimensions Length (Inches/mm) Light Output (lm) Lumens Per Watt Voltage Lines Part Mounting Dimensions Length (Inches/mm) Light Output (lm) Lumens Per Watt Voltage LED Indoor Refrigeration RDL Display Range Lighting Range Refrigeration RDL Display Range Lighting Range ELVP80CB 90 0 6.8 000 Centre 8/9 67 97 90 V ELFDS8CS 907 8 00 Centre 8/9 8 0 8 V ELVP80RB 90 0 0.08 000 End Right 8/9 89 89 90 V ELFDS8RS 9076 00 End Right 8/9 097 9 8 V ELVP80LB 90 0 0.08 000 End Left 8/9 89 89 90 V ELFDS8LS 9077 00 End Left 8/9 097 9 8 V ELVP60CS 906 0.6 00 Centre 60/ 78 88 90 V ELFDS8CB 9078 0 8 00 Centre 8/9 8 0 8 V ELVP60RS 907. 00 End Right 60/ 08 80 90 V ELFDS8RB 9079 0 00 End Right 8/9 097 9 8 V ELVP60LS 908. 00 End Left 60/ 08 80 90 V ELFDS8LB 9070 0 00 End Left 8/9 097 9 8 V ELVP60CB 909 0 0.6 00 Centre 60/ 78 88 90 V ELFDS60CS 9078 00 Centre 60/ 0 8 V ELVP60RB 9060 0. 00 End Right 60/ 08 80 90 V ELFDS60RS 9078 00 End Right 60/ 7 9 8 V ELVP60LB 906 0. 00 End Left 60/ 08 80 90 V ELFDS60LS 9078 00 End Left 60/ 7 9 8 V ELVP600CS 909 0.6 000 Centre 60/ 8 90 90 V ELFDS60CB 90786 0 00 Centre 60/ 0 8 V ELVP600RS 909. 000 End Right 60/ 098 8 90 V ELFDS60RB 90787 0 00 End Right 60/ 7 9 8 V ELVP600LS 909. 000 End Left 60/ 098 8 90 V ELFDS60LB 90788 0 00 End Left 60/ 7 9 8 V ELVP600CB 909 0 0.6 000 Centre 60/ 8 90 90 V ELFDS67CS 9078 7 00 Centre 67/708 76 0 8 V ELVP600RB 9096 0. 000 End Right 60/ 098 8 90 V ELFDS67RS 9078 8 00 End Right 67/708 66 9 8 V ELVP600LB 9098 0. 000 End Left 60/ 098 8 90 V ELFDS67LS 9078 8 00 End Left 67/708 66 9 8 V ELVP600CS 9099 0.6 000 Centre 60/ 96 97 90 V ELFDS67CB 9078 0 7 00 Centre 67/708 76 0 8 V ELVP600RS 9000. 000 End Right 60/ 9 89 90 V ELFDS67RB 9078 0 8 00 End Right 67/708 66 9 8 V ELVP600LS 900. 000 End Left 60/ 9 89 90 V ELFDS67LB 90786 0 8 00 End Left 67/708 66 9 8 V Immersion TM Elite Freezer Door Premium ELVP600CB 900 0 0.6 000 Centre 60/ 96 97 90 V ELVP600RB 900 0. 000 End Right 60/ 9 89 90 V ELVP600LB 900 0. 000 End Left 60/ 9 89 90 V ELVP67CS 906. 00 Centre 67/708 08 88 90 V ELVP67RS 906. 00 End Right 67/708 08 80 90 V ELVP67LS 906. 00 End Left 67/708 08 80 90 V ELVP67CB 906 0. 00 Centre 67/708 08 88 90 V ELVP67RB 9066 0. 00 End Right 67/708 08 80 90 V ELVP67LB 9067 0. 00 End Left 67/708 08 80 90 V ELVP670CS 9007. 000 Centre 67/708 90 90 V ELVP670RS 9008. 000 End Right 67/708 098 8 90 V ELVP670LS 9009. 000 End Left 67/708 098 8 90 V ELVP670CB 90060 0. 000 Centre 67/708 90 90 V ELVP670RB 9006 0. 000 End Right 67/708 098 8 90 V ELVP670LB 9006 0. 000 End Left 67/708 098 8 90 V ELVP670CS 9006. 000 Centre 67/708 9 97 90 V ELVP670RS 9006. 000 End Right 67/708 9 89 90 V ELVP670LS 9006. 000 End Left 67/708 9 89 90 V ELVP670CB 90066 0. 000 Centre 67/708 9 97 90 V ELVP670RB 90067 0. 000 End Right 67/708 9 89 90 V ELVP670LB 90068 0. 000 End Left 67/708 9 89 90 V Immersion Elite French Door ELFDS80CS 9078 8 000 Centre 8/9 87 0 8 V ELFDS80RS 9078 000 End Right 8/9 6 9 8 V ELFDS80LS 9078 000 End Left 8/9 6 9 8 V ELFDS80CB 9078 0 8 000 Centre 8/9 87 0 8 V ELFDS80RB 9078 0 000 End Right 8/9 6 9 8 V ELFDS80LB 90786 0 000 End Left 8/9 6 9 8 V ELFDS600CS 90789 000 Centre 60/ 99 0 8 V ELFDS600RS 90780 000 End Right 60/ 0 9 8 V ELFDS600LS 9078 000 End Left 60/ 0 9 8 V ELFDS600CB 9078 0 000 Centre 60/ 99 0 8 V ELFDS600RB 9078 0 000 End Right 60/ 0 9 8 V ELFDS600LB 9078 0 000 End Left 60/ 0 9 8 V ELFDS670CS 90787 7 000 Centre 67/708 8 0 8 V ELFDS670RS 90788 8 000 End Right 67/708 70 9 8 V ELFDS670LS 90789 8 000 End Left 67/708 70 9 8 V ELFDS670CB 90780 0 7 000 Centre 67/708 8 0 8 V ELFDS670RB 9078 0 8 000 End Right 67/708 70 9 8 V ELFDS670LB 9078 0 8 000 End Left 67/708 70 9 8 V ELFDS80CS 90787 8 000 Centre 8/9 9 08 8 V ELFDS80RS 90788 000 End Right 8/9 77 98 8 V ELFDS80LS 90789 000 End Left 8/9 77 98 8 V
LED Indoor Solutions / Refrigeration Display Lighting LED Indoor Lines Part Mounting Dimensions Length (Inches/mm) Light Output (lm) Lumens Per Watt Voltage HID Picard France GE SOLUTIONS: Immersion TM RDL Solution Refrigeration RDL Display Range Lighting Range ELFDS80CB 90780 0 8 000 Centre 8/9 9 08 8 V ELFDS80RB 9078 0 000 End Right 8/9 77 98 8 V ELFDS80LB 9078 0 000 End Left 8/9 77 98 8 V ELFDS600CS 9078 000 Centre 60/ 90 08 8 V ELFDS600RS 90786 000 End Right 60/ 7 98 8 V ELFDS600LS 90787 000 End Left 60/ 7 98 8 V Immersion Elite French Door ELFDS600CB 90788 0 000 Centre 60/ 90 08 8 V ELFDS600RB 90789 0 000 End Right 60/ 7 98 8 V ELFDS600LB 90780 0 000 End Left 60/ 7 98 8 V ELFDS670CS 9078 7 000 Centre 67/708 9 08 8 V ELFDS670RS 9078 8 000 End Right 67/708 766 98 8 V ELFDS670LS 9078 8 000 End Left 67/708 766 98 8 V ELFDS670CB 90786 0 7 000 Centre 67/708 9 08 8 V ELFDS670RB 90787 0 8 000 End Right 67/708 766 98 8 V ELFDS670LB 90788 0 8 000 End Left 67/708 766 98 8 V High Intensity Discharge Lamps 6
High Intensity Discharge Lamps John Lewis UK GE SOLUTIONS: ConstantColor CMH HID Exceptional light quality, indoors and outdoors Our advanced HID ranges encompass ConstantColor Ceramic Metal Halide (CMH), Quartz Metal Halide (QMH) and Lucalox High Pressure Sodium (HPS) technologies, enabling us to offer the right solution across a wide range of applications. These ultra-efficient lighting solutions combine high efficacy with a long life to deliver the optimum lighting solution for a range of commercial and industrial applications. HID ConstantColor CMH Light quality Colour is a vital part of lighting in so many ways. Retail displays need to be lit to show products colours. Security cameras need to be able to identify colours accurately. And in modern cities that never sleep, buildings, sculptures and parks look their best when lighting brings out their true colours. ConstantColor CMH Lamps deliver the quality of light that these situations demand. Reliability It is also important that this high performance is maintained, and GE s ConstantColor technology delivers the best possible lumen maintenance to ensure that merchandise, streets and statues are lit better for longer and with no deterioration of light quality as lamps approach the end of their life. Low cost of ownership The excellent lumen maintenance of ConstantColor CMH Lamps means extended replacement cycles and, therefore, savings on maintenance cost. An extension of at least one year can be assumed when calculating relamping cycles. High efficacy more lumens per Watt Long rated life: up to 000 hours High lumen maintenance Why CMH? Highly controllable point source Superb colour rendition and stability Reliability, efficiency and longevity Superb lumen maintenance Instant replacement of less eco friendly products Wide choice GE s ConstantColor CMH range is second to none in the variety that is on offer for both indoor and outdoor applications. Indoors, these include retail display lighting and industrial high bay lighting, and outdoors, street lighting and city beautification. The range includes lamps for all the common formats - GU6., G8., G, E7/E0 and Rx7s, as well as AR, MR6 and PAR reflectors. Lighting designers can choose from 000K and 00K colours and their needs are also catered for by the flexibility of ballasts that can be used. GE works closely with customers and offers a list of top ballast manufacturers. GE ConstantColor CMH Lamps provide high quality light with low cost of ownership for every type of application, but there are also products specially developed for particular uses. GE ConstantColor CMH Standard CMH Standard is the widest product range, one that offers great performance and value for replacement applications. GE ConstantColor CMH Precise Developed for the retail environment, CMH Precise is GE s premium CMH range, with enhanced colour and improved lumen maintenance. GE ConstantColor CMH StreetWise CMH StreetWise combines dimmable white light with high efficiency for street lighting. Long life and high lumen maintenance ensure maintenance is minimised. 8 9
High Intensity Discharge Lamps HID CMH Indoors GE ConstantColor CMH Standard Lamps combine great performance and best-in-class rated life to offer an attractive, value for money solution for replacement applications. efficiency and longer relamping cycles ensure a low total cost of ownership. Complete range of retail lamps for wide range of applications efficient replacement solution on existing installations Reduced energy bills and extended maintenance cycles Reduced cost of ownership through longer life Enables planned lighting maintenance for fixed interval replacement, optimised labour costs and reduced lamp failures CMH Outdoors Lighting accounts for more than 0% of energy consumption around the world. Reduce consumption per luminaire, and everybody benefits. Our energy efficient ConstantColor CMH StreetWise range has the potential to significantly reduce global energy consumption, while at the same time improving road safety. An outstanding combination of bright white light and energy efficiency makes these lamps the ideal solution for street and roadway lighting. This outstanding quality of light much closer to natural daylight promotes safer driving through easier recognition of shapes and colour, makes pedestrians feel more comfortable and secure, and enhances the urban environment. HID Why Precise? Greatly improved lumen output (000lm W and 7800lm 70W) Excellent lumen maintenance (70W 80% @ 000 h) Outstanding useful life (B0: 000 h) Superb light quality and colour rendering of CRI 90+ Improved rendering of deep red colours (R9) Improved lamp-to-lamp colour control Universal burning position Robust and reliable performance initially and through life LONGER LIFE AND MORE LUMENS OVER USEFUL LIFE EXCELLENT LUMEN MAINTENANCE 0% MORE LUMENS AT 000 HOURS LIFE THAN STANDARD LAMPS Our ConstantColor CMH Precise range is an innovative lighting solution designed to ensure the best possible results in the retail environment with significantly improved lumen maintenance and enhanced quality of light. The range allows retailers to choose the best option for their visual requirements. Cost effective direct retrofit for existing retail installations Longer life and more lumens over useful life Outstanding lumen output up to 0 LPW Excellent lumen maintenance 0% more lumens at 000 hours life than standard lamps Compatible with existing GE electronic ballasts and other major GE-validated manufacturers COST EFFECTIVE DIRECT RETROFIT FOR EXISTING RETAIL INSTALLATIONS GE s new generation of CMH StreetWise Lamps especially designed for outdoor lighting offers the best of both worlds. Bright, white, natural light and low costs for both running and maintenance. With CMH lighting, streets and other public spaces can feel safer for pedestrians. More than that, their daylight colour rendering improves the ability of drivers to recognise shapes and colours, especially in peripheral vision. This also promotes quicker driver response times. HIGH EFFICIENCY AND LONG LIFE UP TO 000 HOURS VIVID COLOUR, BRIGHTER LIGHT Other products in our Outdoor ranges include GE Lucalox High Pressure Sodium Lamps and a choice of Quartz Metal Halide Lamps from 70 000 W and rated life up to 60 000 hours. DIMMABLE FOR EXTRA ENERGY SAVING High efficiency and long life up to 000 hours Dimmable for extra energy saving Uniform lighting for roadways Vivid colour, brighter light Lower running cost, lower CO emissions Improved safety and security for pedestrians and vehicles Ideal for integrated systems with dimming, remote monitoring and remote control John Lewis UK Erzsébet Bridge Budapest GE SOLUTIONS: ConstantColor CMH GE SOLUTIONS: CMH 0W 60 6
High Intensity Discharge Lamps overview HID Single Ended Supermini Precise, Ultra and Standard (GU6.) : GU6. Wattages: 0 W Colours: 80, 90, 9 Rated life: 0 000 8 000 h Single Ended Mini Precise, Ultra, Ultra White and Standard (TC) : G8. Wattages: 0 70W Colours: 80, 90, 9 Rated life: 000 8 000 h Single Ended Precise, Ultra, Ultra White and Standard (T) : G Wattages: 0 0W Colours: 80, 90, 9 Rated life: 000 8 000 h Open Rated Elliptical : E7 Wattages: 70 0W Colours: 9, 90 Finish: Clear or Diffuse Rated life: 000 h Elliptical : E7, E0 Wattages: 70 00W Colours: 80 Finish: Clear or Diffuse Rated life: 0 000 000 h StreetWise : E7, E0 Wattages: 0 0W Colours: 70 Finish: Clear Rated life: 000 h HID Double Ended (TD) : RX7s or RX7s- Wattages: 0W Colours: 80, 9 Rated life: 000 h Tubular : E7, E0 Wattages: 70 00W Colours: 80, 8, 9 Finish: Clear Rated life: 0 000 000 h Open Rated Tubular : E0 Wattages: 0W Colours: 80, 9 Finish: Clear Rated life: 000 h ConstantColor CMH (Ceramic Metal Halide) GU6., TC, T, TD ConstantColor CMH (Ceramic Metal Halide) Elliptical and Tubular MR6 Precise, and Standard : GX0 Wattages: 0 W Colours: 80, 90, 9 Rated life: 0 000 8 000 h Beam spread: 0 AR : GX8. Wattages: 70W Colours: 90 Rated life: 000 h Beam spread: 0 0 PAR0 : E7 Wattages: 0 W Colours: 80, 9 Rated life: 0 000 000 h Beam spread: 0 PAR0 : E7 Wattages: 0 70W Colours: 80, 9 Rated life: 0 000 000 h Beam spread: 0 0 CMH Standard Ballasts A range of standard ballasts for 70W CMH lamps CMH Miniature Ballasts A range of miniature ballasts for 0 W CMH lamps ConstantColor CMH (Ceramic Metal Halide) Reflectors CMH Ballasts 6 6
High Intensity Discharge Lamps overview HID Single Ended : G Wattages: 70 0W Colours: 000 00K CRI: 70 80 Rated life: 6 000 h Double Ended : Rx7s-Fc Wattages: 70 0W Colours: 000 600K CRI: 7 90 Rated life: 8 000 000 h Double Ended Coloured : RX7s- Wattages: 0W Colours: Green, Blue, Magenta Rated life: 6 000 h Lucalox XO Superlife : E7, E0 Wattages: 70 00W Feature: Extra high lumen output and Twin Arctubes for extra life Finish: Tubular Clear or Elliptical Diffuse Rated life: 0 000 60 000 h Lucalox XO : E7, E0 Wattages: 0 600W Feature: Extra high lumen output Finish: Tubular Clear or Elliptical Diffuse Rated life: 000 000 h Lucalox Superlife : E7, E0 Wattages: 0 0W Feature: Twin Arctubes for extra life Finish: Elliptical Diffuse Rated life: 0 000 60 000 h HID Tubular : E0 Wattages: 0 00W Colours: 00 6000K CRI: 70 90+ Finish: Clear Rated life: 000 h Elliptical : E0 Wattages: 0W Colours: 000 6000K CRI: 70 90 Finish: Clear or Diffuse Rated life: 000 000 h Lucalox Standard : E7, E0 Wattages: 70 000W Finish: Tubular Clear or Elliptical Diffuse Rated life: 000 8 00 h Lucalox Internal Ignitor : E7 Wattages: 0 70W Feature: Internal ignitor Finish: Elliptical Clear or Diffuse Rated life: 000 7 00 h Arcstream Metal Halide Operates on suitable metal halide/high pressure sodium ballast and metal halide ignitor Lucalox High Pressure Sodium Standard Elliptical : E0 Wattages: 0 000W Colours: 700 00K CRI: 6 70 Finish: Clear or Diffuse Rated life: 0 000 0 000 h High Output Elliptical : E0 Wattages: 0 00W Colours: 00 00K CRI: 6 70 Finish: Clear or Diffuse Rated life: 0 000 h Linear : RX7SM - spec Wattages: 00 000W Colours: 00K CRI: 6 Rated life: 6 000 h Tubular Clear : E0 Wattages: 000 000W Colours: 000 6000K CRI: 6 9 Rated life: 000 8 000 h Internal Ignitor : E0 Wattages: 000W Colours: 000 6000K CRI: 6 9 Rated life: 000 000 h Multi-Vapour Metal Halide Operates from CWA Control Gear Sportlight Metal Halide For sports and floodlighting Tubular : E0 Wattages: 00W Colours: 6000K CRI: 90 Finish: Clear Rated life: 000 h Elliptical : E0 Wattages: 00W Colours: 000 6000K CRI: 6 90 Finish: Clear or Diffuse Rated life: 000 h Kolorlux Mercury Standard* : E7, E0 Wattages: 0 00W Rated life: 6 000 0 000 h * only direct shipment Mixed Light* : E7, E0 Wattages: 60 00W Voltage: 0 0V Rated life: 8 000 h * only direct shipment Kolorarc Metal Halide Operates from suitable mercury or metal halide ballast rated.a and metal halide ignitor Mercury Lamps 6 6
High Intensity Discharge Lamps High Intensity Discharge Lamps Colour Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) Colour Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) HID ConstantColor CMH Supermini 0 9 GU6. CMH0/TC/UVC/80/GU6. 099 6 80 U 000 000 A 90 GU6. CMH/T/UVC/90/U/GU6. PRECISE 6768 000 90 U 8 000 8 000.9 A+ 9 GU6. CMH/T/UVC/U/90/GU6. ULTRA* 76 00 90 U 6 00 6 00. A+ 90 GU6. CMH/T/UVC/90/GU6. 8866 00 90 U 0 000 0 000. A+ 9 GU6. CMH/T/UVC/9/GU6. 8867 00 9 U 000 000. A * Will be phased out ConstantColor - CMH Double Ended 90 RX7s CMH/TD/UVC/80/RX7s 78 00 80 HOR± 000 8 A 70 90 RX7s CMH70/TD/UVC/80/RX7s 690 7 000 80 HOR± 000 8 80.8 A+ 70 90 RX7s CMH70/TD/UVC/9/RX7s 8698 6 00 9 HOR± 000 8 79. A+ 0 96 RX7s- CMH0/TD/UVC/80/RX7s- 69 00 80 HOR± 000 7 8.8 A+ 0 96 RX7s- CMH0/TD/UVC/9/RX7s- 869 00 9 HOR± 000 7. A+ HID ConstantColor CMH Single Ended Mini 0 90 G8. CMH0/TC/UVC/U/80/G8. PLUS 988 60 80 U 000 000 8..8 A 90 G8. CMH/T/UVC/U/80/G8. Plus 7 00 80 U 6 00 6 00 8.. A+ 90 G8. CMH/TC/UVC/U9/G8. 68 00 9 U 8 000 8 000 8.. A 90 G8. CMH/TC/UVC/U/90/G8. PRECISE 6768 000 90 U 8 000 8 000 8..9 A+ 9 G8. CMH/TC/U/UVC/90/G8. ULTRA* 760 600 90 U (ECG)/V60 (EM) 6 00 6 00 8.. A+ 70 90 G8. CMH70/TC/UVC/U/9/G8. 69 6 00 9 U 000 000 8. 80. A 70 8 G8. CMH70/TC/UVC/U/80/G8. PLUS 67698 7 000 80 U 000 000 8. 79. A+ 70 8 G8. CMH70/TC/UVC/U/90/G8. PRECISE 6768 7 800 90 U 8 000 8 000 8. 80. A+ 70 86 G8. CMH70/TC/UVC/U/90/G8. ULTRA* 967 6 00 90 U 8 000 8 000 8. 80 A+ * Will be phased out ConstantColor CMH Single Ended 0 90 G CMH0/T/UVC/U/80/G PLUS 708 60 80 U 000 000 90..8 A 90 G CMH/T/UVC/U/80/G PLUS 7 00 80 U 6 00 6 00 90.. A+ 90 G CMH/T/UVC/U/90/G PRECISE 6768 000 90 U 8 000 8 000 90..9 A+ 9 G CMH/T/U/UVC/90/G ULTRA* 76 600 90 U (ECG)/V60 (EM) 6 00 6 00 90.. A+ 90 G CMH/T/UVC/U/9/G 9 00 9 U 8 000 8 000 90..6 A 70 90 G CMH70/T/UVC/U/80/G Plus 67699 7 000 80 U 000 000 90 9 76. A+ 70 90 G CMH70/T/UVC/U/9/G 00 6 000 9 U 000 000 90 9 80. A+ 70 8 G CMH70/T/UVC/U/90/G PRECISE 6768 7 800 90 U 8 000 8 000 90 9 80. A+ 70 86 G CMH70/T/UVC/U/90/G ULTRA WHITE* 696 6 600 90 U 8 000 8 000 90 9 80. A+ 70 86 G CMH70/T/UVC/U/90/G ULTRA * 967 6 00 90 U 8 000 8 000 90 9 80. A+ 0 90 G CMH0/T/UVC/U/80/G 00 000 80 U 000 000 00 9 60. A+ 0 90 G CMH0/T/UVC/U/9/G 00 000 9 U 000 000 00 9 6. A * Will be phased out ConstantColor - CMH MR6 Candela (cd) Beam Angle ( ) Colour Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) 0 9 GX0 CMH0/MR6/UVC/80/GX0/SP 000 9 000 80 U 000 000..8 A 0 9 GX0 CMH0/MR6/UVC/80/GX0/FL GX0 00 900 80 U 000 000..7 A 0 9 GX0 CMH0/MR6/UVC/80/GX0/WFL GX0 69 00 0 80 U 000 000..8 A 9 GX0 CMH/MR6/U/90/GX0/SP PRECISE 67686 8 000 90 U 8 000 8 000. 9. A 9 GX0 CMH/MR6/U/90/GX0/FL PRECISE 67687 7 00 90 U 8 000 8 000. 9. A 9 GX0 CMH/MR6/U/90/GX0/WFL PRECISE 67697 700 0 90 U 8 000 8 000. 9. A 90 GX0 CMH/MR6/UVC/90/GX0/SP GX0 8868 6 000 90 U 0 000 0 000.. A 90 GX0 CMH/MR6/UVC/90/GX0/FL GX0 8869 00 90 U 0 000 0 000.. A 90 GX0 CMH/MR6/UVC/90/GX0/WFL GX0 88660 000 0 90 U 0 000 0 000.. A 90 GX0 CMH/MR6/UVC/9/GX0/SP GX0 8866 6 000 9 U 000 000.. A 90 GX0 CMH/MR6/UVC/9/GX0/FL GX0 8866 00 9 U 000 000.. A 90 GX0 CMH/MR6/UVC/9/GX0/WFL GX0 8866 000 0 9 U 000 000.. A ConstantColor - CMH AR 90 GX8. CMH/R/UVC/90/GX8./SP0 99989 000 0 90 U 000 000 9. A 6 6 90 GX8. CMH/R/UVC/90/GX8./FL 99990 0 000 90 U 000 000 9. A 6 6 90 GX8. CMH/R/UVC/90/GX8./FL0 9999 000 0 90 U 000 000 9. A 6 6 70 9 GX8. CMH70/R/UVC/90/GX8./SP0 9999 0 000 0 90 U 000 000 9 6. A 6 6 70 9 GX8. CMH70/R/UVC/90/GX8./FL 9999 8 000 90 U 000 000 9 6. A 6 6 70 9 GX8. CMH70/R/UVC/90/GX8./FL0 9999 8 00 0 90 U 000 000 9 6. A 6 6 ConstantColor - CMH PAR 0 - explanation For further information check the glossary CMH 70 / T / UVC / U / 9 0 / G PRECISE (70) Identifies Lamp s wattage (CMH) Family CMH - ConstantColor CMH ARC - Arcstream KRC - Kolorarc MPR/MVR - Multi-Vapor SPL - Sportlight LU - Lucalox H - Mercury ML - Blended Light BLS - Ballast (UVC) UV Control (T) Identifies the lamp format. TD - Double Ended E - Elliptical Clear D - Elliptical Diffused L - Linear PARxx - PAR + size T - Tubular Clear (U) Operating Position U - Universal HOR - Horizontal BU - Base Up VBU - Vertical Base Up (G): Identifies the cap type (9) Colour rendering 6 - nom 60, min 7 (Group B) 7 - nom 70, min 67 (Group A) 8 - nom 80, min 77 (Group B) 9 - nom 90, min 87 (Group A) (0) Colour temperature XX = First digits of temperature in Kelvin - XX00K Example: 0 is 000K 0 9 E7 CMH0PAR0/UVC/80/E7/SP0 678 000 0 80 U 000 000 9 6.7 A 7 0 9 E7 CMH0/PAR0/UVC/80/E7/FL 68 70 80 U 000 000 9 6.9 A 7 90 E7 CMH/PAR0/UVC/80/E7/SP0 68 000 0 80 U 0 000 0 000 9 6.7 A 7 90 E7 CMH/PAR0/UVC/80/E7/FL 68 7 00 80 U 0 000 0 000 9 6.7 A 7 90 E7 CMH/PAR0/UVC/9/E7/SP0 890 9 0 0 9 U 0 000 0 000 9 6. A 7 90 E7 CMH/PAR0/UVC/9/E7/FL 99 6 90 9 U 0 000 0 000 9 6.8 A 7 6 7 66 67
High Intensity Discharge Lamps High Intensity Discharge Lamps Candela (cd) Beam Angle ( ) Colour Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) Colour Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) HID ConstantColor - CMH PAR 0 0 9 E7 CMH0PAR0/UVC/80/E7/SP0 697 9 800 0 80 U 000 000 9..8 A 6 0 9 E7 CMH0PAR0/UVC/80/E7/FL 68 900 80 U 000 000 9..8 A 6 90 E7 CMH/PAR0/UVC/80/E7/SP0 689 9 600 0 80 U 0 000 0 000 9.. A 6 90 E7 CMH/PAR0/UVC/80/E7/FL 690 000 80 U 0 000 0 000 9.. A 6 90 E7 CMH/PAR0/UVC/9/E7/SP0 99 6 700 0 9 U 0 000 0 000 9..7 A 6 90 E7 CMH/PAR0/UVC/9/E7/FL 9 0 00 9 U 0 000 0 000 9..6 A 6 70 90 E7 CMH70/PAR0/UVC/80/E7/SP 68 800 80 U 000 000 9. 8.8 A 6 70 90 E7 CMH70/PAR0/UVC/80/E7/FL0 68 0 000 0 80 U 000 000 9. 8.8 A 6 70 90 E7 CMH70/PAR0/UVC/9/E7/SP 760 00 9 U 0 000 0 000 9. 8.7 A 6 70 90 E7 CMH70/PAR0/UVC/9/E7/FL0 769 9 000 0 9 U 0 000 0 000 9. 8.7 A 6 ConstantColor - CMH Elliptical Clear 70 97 E7 CMH70/E/UVC/U/80/E7/C 9798 6 00 80 U 000 000 8 77.7 A+ 6 00 0 E7 CMH00/E/UVC/U/80/E7/C 9798 9 00 80 U 000 000 8 A+ 6 ConstantColor - CMH Tubular Clear StreetWise 0 87 E7 CMH0/TT/UVC/U/70/E7 STREETWISE 90867 0 70 U 000 000 6 9 9,9 A+ 6 70 9/90 E7 CMH70/TT/UVC/70/E7 STREETWISE 770 7 60 /7 00 70 HOR±/VBU 0 000 000 6 9 78. A+ 6 00 00/9 E0 CMH00/TT/UVC/70/E0 STREETWISE 7799 0 900/0 00 70 HOR±/VBU 0 000 000 8 07.8 A+ 6 0 00 E0 CMH0/TT/UVC/70/E0 STREETWISE 770 6 00 70 HOR± 000 8 6 A+ 6 ConstantColor - CMH Tubular Clear 70 9 E7 CMH70/TT/UVC/80/E7 87 6 00 80 U 000 0 000 6 7 80.8 A+ 7 00 09 E0 CMH00/TT/UVC/80/E0 978 9 00 80 U 0 000 000 09 8 0. A+ 7 0 9 E0 CMH0/UVC/T/U/8/E0 00 8 U 000 000 09 8 60. A+ 7 0 00 E0 CMH0/TT/UVC/80/E0 879 000 80 U 000 0 000 09 8 6.6 A+ 7 0 7 E0 CMH0/TT/UVC/U/80/E0 089 000 80 U 000 000 60 8 88. A+ 7 0 0 E0 KRC0/CMH/80/T/H/E0 00 0 000 80 HOR 000 60 8.6 A 7 0 07 E0 CMH0/T/U/9/E0 66 000 9 U 6 000 6 000 60 8 8.6 A+ 7 00 0 E0 CMH00/TT/UVC/U/80/E0 067 000 80/86 * U 0 000 0 000 78 60. A+ 7 *80 in horizontal burning position, 86 in vertical burning position HID Colour Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) ConstantColor - CMH Tubular Clear, Open Rated 0 00 E0 CMH0/UVC/O/T/U/80/E0 6 000 80 U 000 000 09 8 6. A+ 8 0 00 E0 CMH0/UVC/O/T/U/9/E0 7 000 9 U 000 000 09 8 6. A 8 ConstantColor - CMH Elliptical Clear, Open Rated 0 9 E7 CMH0/UVC/O/U/9/E7/C 8 00 9 U 000 000 8 6. A 6 ConstantColor - CMH Elliptical Diffuse Type 70 97 E7 CMH70/E/UVC/U/80/E7/D 97979 6 000 80 U 000 000 8 78.9 A 6 00 0 E7 CMH00/E/UVC/U/80/E7/D 9798 8 700 80 U 0 000 0 000 8 0. A+ 6 0 7 E0 CMH0/E/UVC/U/80/E0/D 09 00 80 U 000 000 7 90 89. A+ 00 0 E0 CMH00/E/UVC/U/80/E0/D 087 9 000 80/86 U 0 000 0 000 8 0.9 A+ 6 ConstantColor - CMH Elliptical Diffuse, Open Rated 70 97 E7 CMH70/UVC/O/U/90/E7/D 8 00 90 U 000 000 8 8 A 6 0 9 E7 CMH0/UVC/O/U/90/E7/D 86 00 90 U 000 000 8 6.7 A 6 CMH Standard Ballast 0-0 Integral BLS/E/W/CMH 687 0 0 9 0-0 Remote Cable Clamp BLS/E/W/CMH /R CC 688 70 0 9 70 0-0 Integral BLS/E/70W/CMH 676 0 0 9 CMH Miniature Ballast 0 0-0 Integral BLS/E/0W/CMH 787 6 0 0 0-0 Remote Cable Clamp BLS/E/0W/CMH/R/CC 787 80 0 0-0 Integral BLS/E/W/CMH 787 6 0 0-0 Remote Cable Clamp BLS/E/W/CMH/R/CC 787 80 0 6 7 8 9 0 68 69
High Intensity Discharge Lamps CMH Brand cross reference High Intensity Discharge Lamps CMH Brand cross reference GE Lighting Osram Philips GE Lighting Osram Philips HID ConstantColor CMH CMH0/TC/UVC/80/GU6. HCI-TF 0W/80 WDL PB GU6. CDM-Tm Mini GU6. 0W/80 ConstantColor CMH CMH70/PAR0/UVC/9/E7/FL0 HCI PAR0 70W/9 NDL PB FL 0D CDM-R 70W/9 E7 PAR0L0D HID CMH/T/UVC/90/GU6. HCI-TF /90 WDL PB GU6. CMH70/E/UVC/U/80/E7/C HCI-ET 70W/80 WDL PB CDM-ET 70W /80 E7 CMH/T/UVC/90/GU6. Precise CDM-Tm Elite Mini GU6. W/90 CMH00/E/UVC/U/80/E7/C CDM-ET 00W /80 E0 CMH/T/UVC/9/GU6. CMH0/UVC/O/U/9/E7/C HCI-E/P 0W/9 NDL PBMO CL E7 CMH0/TC/UVC/U/80/G8. Plus HCI-TC 0W/80 WDL PB G8. CDM-TC 0W/80 G8. CMH70/E/UVC/U/80/E7/D HCI-E/P 70W/80 NDL PB COE7 CDO-ET Coated 70W/88 E7 CMH/TC/UVC/U/80/G8. Plus HCI-TC W/80 WDL PB G8. CDM-TC W/80 G8. CMH70/UVC/O/U/90/E7/D HCI-E/P 70W/9 NDL Coated E7 CMH/TC/UVC/U/90/G8. Precise HCI-TC /90 WDL PB Excellence G8. CDM-TC Elite W/90 G8. CMH00/E/UVC/U/80/E7/D HCI-E/P 00W/80 WDL PB Coated E7 CDO-ET Coated 00W/88 E0 CMH/TC/UVC/U/9/G8. HCI-TC W/9 NDL PB UVS G8. CDM-TC W/9 G8. CMH0/UVC/O/U/90/E7/D HCI-E/P 0W/9 NDL PB MO E7 CDO-ET Coated 0W/88 E0 CMH70/TC/UVC/U/80/G8. Plus HCI-TC 70W/80 WDL PB G8. CDM-TC 70W/80 G8. CMH0/E/UVC/U/80/E0/D HCI-E 0W/80 WDL PB E0 CMH70/TC/UVC/U/9/G8. HCI-TC 70W/9 NDL PB G8. CDM-TC 70W/9 G8. CMH00/E/UVC/U/80/E0/D CMH70/TC/UVC/U/90/G8. Precise HCI-TC 70/90 WDL PB Excellence G8. CDM-TC Elite 70W/90 G8. CMH0/TT/UVC/70/E7 STREETWISE HCI-TT 0W/80 SUPER Y CDO-TT 0W/88 E7 CMH0/T/UVC/U/80/G Plus CDM-T 0W/80 G CMH70/TT/UVC/80/E7 HCI-TT 70W/80 WDL PB CMH/T/UVC/U/80/G Plus HCI-T W/80 WDL PB G CDM-T W/80 G CMH70/TT/UVC/70/E7 STREETWISE HCI-TT 70W/80 SUPER Y CDO-TT 70W /88 E7 CMH/T/UVC/U/90/G Precise HCI-T /90 WDL PB Excellence CDM-T Elite W/90 G CMH00/TT/UVC/80/E0 HCI-TT 00/80 WDL PB E0 CMH/T/UVC/U/9/G HCI-T W/9 NDL PB UVS G CDM-T W/9 G CMH00/TT/UVC/70/E0 STREETWISE HCI-TT 00W/80 SUPER Y CDO-TT 00W /88 E7 CMH70/T/UVC/U/80/G HCI-T 70W/80 WDL PB G CDM-T 70W/80 G CMH0/TT/UVC/80/E0 HCI-TT 0W/80 WDL PB CMH70/T/UVC/U/9/G HCI-T 70W/9 NDL PB UVS G CDM-T 70W/9 G CMH0/TT/UVC/70/E0 STREETWISE CDO-TT 0W/88 E0 CMH70/T/UVC/U/90/G Precise HCI-T 70/90 WDL PB Excellence CDM-T Elite 70W/90 G CMH0/UVC/T/U/8/E0 HCI-TT 0/80 WDL PB E0 CMH0/T/UVC/U/80/G HCI-T 0W/80 WDL PB G CDM-T 0W/80 G CMH0/UVC/O/T/U/80/E0 HCI-T/P 0W/80 NDL PB E0 CMH0/T/UVC/U/9/G HCI-T 0/NDL PB UVS G CDM-T 0W/9 G CMH0/T/UVC/O/U/9/E0 HCI-T/P 0W/9 NDL PB E0 CMH/TD/UVC/80/RX7s CMH0/TT/UVC/U/80/E0 HCI-T 0W/80 WDL PB E0 CDO-TT 0W /88 E7 CMH70/TD/UVC/80/Rx7s HCI-TS 70W/80 WDL PB UVS RX7S CDM-TD 70W/80 RX7s KRC0/CMH/80/T/H/E0 CMH70/TD/UVC/9/Rx7s HCI-TS 70W/9 NDL PB UVS RX7S CDM-TD 70W/9 RX7s CMH/R/UVC/90/GX8./SP0 CDM-R W/80 GX8. 0D CMH0/TD/UVC/80/Rx7s- HCI-TS 0W/80 WDL PB RX7S- CDM-TD 0W/80 RX7s- CMH/R/UVC/90/GX8./FL CDM-R W/80 GX8. D CMH0/TD/UVC/9/Rx7s- HCI-TS 0W/9 NDL PB RX7S- CDM-TD 0W/9 RX7s- CMH/R/UVC/90/GX8./FL0 CDM-R W/80 GX8. 0D CMH0/MR6/UVC/80/GX0/SP CDM-Rm Mini 0W/80 GX0 MR6 0D CMH70/R/UVC/90/GX8./SP0 CDM-R 70W/80 GX8. 0D CMH0/MR6/UVC/80/GX0/FL CDM-Rm Mini 0W/80 GX0 MR6 D CMH70/R/UVC/90/GX8./FL CDM-R 70W/80 GX8. D CMH0/MR6/UVC/80/GX0/WFL0 CDM-Rm Mini 0W/80 GX0 MR6 0D CMH70/R/UVC/90/GX8./FL0 CDM-R 70W/80 GX8. 0D CMH/MR6/UVC/90/GX0/SP CMH/MR6/UVC/90/GX0/FL CMH/MR6/UVC/90/GX0/WFL0 CMH/MR6/UVC/90/GX0/SP Precise CDM-Rm Elite Mini W/90 GX0 MR6 0D CMH/MR6/UVC/90/GX0/FL Precise CDM-Rm Elite Mini W/90 GX0 MR6 D CMH/MR6/UVC/90/GX0/WFL0 Precise CDM-Rm Elite Mini W/90 GX0 MR6 0D CMH/MR6/UVC/9/GX0/SP CMH/MR6/UVC/9/GX0/FL CMH/MR6/UVC/9/GX0/WFL0 CMH0PAR0/UVC/80/E7/SP0 CMH0/PAR0/UVC/80/E7/FL CMH/PAR0/UVC/80/E7/SP0 HCI-PAR0 W/80 WDL PB SP 0D CDM-R W/80 E7 PAR0L0D CMH/PAR0/UVC/80/E7/FL HCI PAR0 W/80 WDL PB FL 0D CDM-R W/80 E7 PAR0L0D CMH/PAR0/UVC/9/E7/SP0 CDM-R W/9 E7 PAR0L0D CMH/PAR0/UVC/9/E7/FL CDM-R W/9 E7 PAR0L0D CMH0/PAR0/UVC/80/E7/SP0 CMH0/PAR0/UVC/80/E7/FL CMH/PAR0/UVC/80/E7/SP0 HCI PAR0 W/80 WDL PB SP 0D CDM-R W/80 E7 PAR0L0D CMH/PAR0/UVC/80/E7/FL HCI PAR0 W/80 WDL PB FL 0D CDM-R W/80 E7 PAR0L0D CMH/PAR0/UVC/9/E7/SP0 HCI PAR0 W/9 NDL PB SP 0D CDM-R W/9 E7 PAR0L0D CMH/PAR0/UVC/9/E7/FL HCI PAR0 W/9 NDL PB FL 0D CDM-R W/9 E7 PAR0L0D CMH70/PAR0/UVC/80/E7/SP HCI-PAR0 70W/80 WDL SP E7 CDM-R 70W/80 E7 PAR0L0D CMH70/PAR0/UVC/80/E7/FL0 HCI-PAR0 70W/80 WDL FL E7 CDM-R 70W/80 E7 PAR0L0D CMH70/PAR0/UVC/9/E7/SP HCI PAR0 70W/9 NDL PB SP 0D CDM-R 70W/9 E7 PAR0L0D 70 7
High Intensity Discharge Lamps High Intensity Discharge Lamps Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) HID Arcstream Single Ended RG- 0 9 G ARC0/G/80* 886 000 000 80 U 6 000 6 000 76. 6 A 0 0 9 G ARC0/G/8 886 00 00 80 U 6 000 6 000 76. 6 A 0 * Will be phased out WARNING: UV emitted from lamps in Risk Group and. Avoid eye and skin exposure to unshielded product. Arcstream Tubular Clear 0 00 E0 ARC0/T/H/960/E0 66 9 000 6000 90 HOR± 000 0 7 99.6 A 6 0 00 E0 ARC0/T/VBU/960/E0 66 9 000 6000 90 BU± 000 0 7 9.7 A 6 0 E0 ARC0/T/H/7/E0 7 000 00 70 HOR± 000 0 8 9.9 A 6 00 0 E0 ARC00/T/H/7/E0 69 000 00 70 HOR± 000 60 7. A 6 HID Arcstream Single Ended UVC 70 9 G ARC70/T/U/70/G* 9786 00 000 70 U 6 000 6 000 87 77 A 0 The lamp shall be operated only in a luminaire provided with a protective shield. Arcstream Elliptical Diffuse * Will be phased out 0 00 E0 ARC0/D/H/70/E0 6870 9 00 000 70 HOR± 000 7 90 9. A 0 7 0 00 E0 ARC0/D/H/960/E0 007 7 000 6000 90 HOR± 000 7 9 9 B 7 Operating position Rated life (Horizontal) (h) 0 00 E0 ARC0/D/VBU/960/E0 666 7 000 6000 90 VBU± 000 7 90 9.8 A 7 Operating from suitable metal halide / high pressure sodium (HPS) ballast and metal halide ignitor. Arcstream lamps are only suitable for operation in fully enclosed fixtures where lens/diffuser material must be able to contain fragments of hot quartz or glass (up to 00 C). Multi-Vapor Elliptical Clear Arcstream Double Ended UVC 70 9 RX7s ARC70/UVC/TD/70/Rx7s 0 00 000 7 HOR± 000 9 8. A 70 9 RX7s ARC70/UVC/TD/7/Rx7s 6 00 00 7 HOR± 000 8. A 0 9 RX7s- ARC0/UVC/TD/7/Rx7s- 7 000 00 7 HOR± 000 6 A 0 9 RX7s- ARC0/UVC/TD/7/Rx7s- 000 00 7 HOR± 000 6 A 7** E0 MVR7/U/0* 897 600 000 U 0 000 0 000 90 9. A 8 0** E0 MVR0/U/0* 89 0 800 00 6 U 0 000 0 000 90 7.9 A 8 00** E0 MVR00/U/0* 89 0 000 000 6 U 0 000 0 000 9 7 0 A+ 6 8 000** V0 H E0 MVR000/U/0 89 08 000 000 6 U 000 000 90 78 88 A+ 6 8 * Not CE compliant product ** Performance data claimed for vertical position Arcstream Double Ended RG- 0 9 RX7s- ARC0/AQUA/TD/86/Rx7s- 8 000 600 8 HOR± 8 000 6 A 0 0 RX7s- ARC0/TD/9/Rx7s- 977 000 00 90 HOR± 8 000 6 A 0 Fc ARC0/TD/8/Fc 0099 0 000 00 7 HOR± 000 6 7 A 0 Fc ARC0/TD/8/Fc 00 0 000 00 7 HOR± 8 000 6 7 A WARNING: UV emitted from lamps in Risk Group and. Avoid eye and skin exposure to unshielded product. Multi-Vapor Elliptical Diffuse 7** E0 MVR7/C/U/0* 897 900 900 U 0 000 0 000 90 9. A 9 0** E0 MVR0/C/U/0* 89 0 000 900 70 U 0 000 0 000 90 7 A 9 00** E0 MVR00/C/U/0 89 0 000 700 70 U 0 000 0 000 9 7 0 A+ 6 9 * Not CE compliant product ** Performance data claimed for vertical position Colour Operating position Rated life (Horizontal) (h) Multi-Vapor High Output Elliptical Clear 0 E0 MVR0/VBU/0 8600 000 00 6 VBU± 0 000 6 89 7 A 0 00 E0 MVR00/VBU/0 86000 000 000 6 VBU± 0 000 9 7 0 A+ 6 0 Arcstream Double Ended Coloured UVC 0 9 RX7S- ARC0/UVC/TD/GREEN/RX7S- 8 Green HOR± 6 000 6 B 0 9 RX7S- ARC0/UVC/TD/BLUE/RX7S- 8 Blue HOR± 6 000 6 C 0 9 RX7S- ARC0/UVC/TD/MAGENTA/RX7S- 8 Magenta HOR± 6 000 6 B 6 7 8 9 0 7 7
High Intensity Discharge Lamps High Intensity Discharge Lamps Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) Operating position Rated life (Vertical) (h) Rated life (Horizontal) (h) HID Multi-Vapor High Output Elliptical Diffuse 0 E0 MVR0/C/VBU/0 86009 0 000 000 6 VBU± 0 000 6 89 7 A 00* E0 MPR00/C/VBU/0/0 8906 8 000 00 70 VBU± 0 000 9 7 0 A+ 6 00 E0 MVR00/C/VBU/0 8977 0 000 700 70 VBU± 0 000 9 7 0 A+ 6 Operating from CWA control gear. Initial lumen values and Rated Average Life based on vertical orientation for Universal types. Multi-Vapor lamps must operated in fully enclosed fixtures except those marked *when used VBU or VBD +/-. For lamps requiring enclosed fixtures, lens/diffuser material must be able to contain fragments of hot quartz or glass (up to 00 C). Lamps operated in the vertical position that are not designated Enclosed Fixtures only lamp may be used in an open or enclosed lighting fixture depending upon the application and operating environment. For example, if the lamp is located near combustible material or in an area which is unoccupied for extended periods, an enclosed fixture which can contain fragments of hot quartz or glass is recommended. For more information contact your fixture manufacturer. Sportlight Linear 00 0 RX7SM SPL00/L/H/6/Rx7SM 690 0 000 00 6 HOR± 6 000 6 67 A 000 0 spec. SPL000/L/H/6/SPEC 69 00 000 00 6 HOR± 6 000 6 9. A 6 Sportlight Tubular Clear 000 0 E0 SPL000/T/H/960/E0 8888 80 000 6000 9 HOR±60º 8 000 6 7. A 7 000 E0 SPL000/0V/T/H/60/E0 6078 89 000 000 6 HOR±7 000 0 0 090 A+ 7 000 E0 SPL000/80V/T/H/960/E0 00 70 000 6000 9 HOR±60 000 0 0 9.8 A 7 Sportlight Internal Ignitor 000 E0 SPL000/80V/I/T/H/960/E0 00 70 000 6000 9 HOR±60 000 0 0 9 A 8 000 E0 SPL000/80V/I/T/H/60/E0 8 90 000 000 6 HOR±7 000 0 0 8. A+ 8 HID Please refer to technical data sheet for appropriate ballast and ignitors. Sportlight lamps are only suitable for use in fully enclosed fixtures, where fixture lens/diffuser material Kolorarc Tubular Clear is able to contain fragments of hot quartz or glass (up to 00 C). 00 0 E0 KRC00/T/H/960/E0 00 8 00 6000 90 HOR± 000 70 8 8. A 00 0 E0 KRC00/T/VBU/960/E0 070 7 000 6000 90 VBU± 000 70 8 0.8 A Kolorarc Elliptical Clear 00 E0 KRC00/E/VBU/6/E0 * 687 00 00 6 VBU±0 000 86. A 0 Operating position Rated Life (h) * Will be phased out Lucalox XO Superlife Tubular Clear Kolorarc Elliptical Diffuse 70 90 E7 LU 70/XO/SBY/T/E7 888 6 600 000 U 0 000 6 9 8. A+ 9 00 0 E0 KRC00/D/H/960/E0 * 08 6 800 6000 90 HOR± 000 8 08 B 6 00 0 E0 KRC00/D/VBU/960/E0 087 00 6000 90 VBU± 000 8 0.7 A 6 00 E0 KRC00/D/VBU/70/E0 687 00 000 70 VBU±0 000 86. A 0 00 E0 KRC00/D/H/70/E0 * 687 8 000 000 70 HOR± 000 86 0 9.8 A+ 0 * will be phased out Operating from suitable mercury or metal halide ballast rated A and metal halide ignitor. Low loss ballast recommended for 00W 6000K (960) products see lamp data sheet for details. Enhanced lumen performance operating from special High Output ballast rated.8a see lamp data sheet for details. Kolorarc lamps are only suitable for operation in fully enclosed fixtures where lens/diffuser material must be able to contain fragments of hot quartz or glass (up to 00 C) 00 00 E0 LU 00/XO/SBY/T/E0 886 0 00 000 U 60 000 8 0. A+ 9 0 00 E0 LU 0/XO/SBY/T/E0 7877 7 00 000 U 60 000 8 68.9 A+ 9 0 00 E0 LU 0/XO/SBY/T/E0 7878 000 000 U 000 60 8 88.7 A+ 9 00 00 E0 LU 00/XO/SBY/T/E0 7879 800 000 U 000 8 8 0.6 A++ 9 Lucalox XO Superlife Elliptical Diffuse 0 8 E7 LU0/8/XO/SBY/D/E7 978 00 000 U 0 000 6 7 8. A 0 70 90 E7 LU70/XO/SBY/D/E7 887 6 000 000 U 0 000 6 7 80. A 0 00 00 E0 LU00/XO/SBY/D/E0 88 0 000 000 U 60 000 86 7. A+ 0 6 7 8 9 0 7 7
High Intensity Discharge Lamps High Intensity Discharge Lamps Operating position Rated Life (h) HID Lucalox XO Tubular Clear 0 8 E7 LU0/8/XO/T/7 97 00 00 U,000 6 9 9.7 A 70 90 E7 LU70/90/XO/T/7 97 6 600 00 U 0 000 6 9 80. A+ HID 00 00 E0 LU00/00/XO/T/0 976 0 700 00 U 0 000 8.9 A+ 0 00 E0 LU0/0/XO/T/0 977 7 00 00 U 000 8 68. A+ 0 00 E0 LU0/XO/T/0 978 00 00 U 000 60 8 8.8 A+ 00 00 E0 LU00/XO/T/0 969 6 00 00 U 000 9 8 8. A++ 600 E0 LU600/XO/T/0 970 88 00 00 U 000 9 8 667. A++ Lucalox XO Elliptical Diffuse John Lewis UK GE SOLUTIONS: ConstantColor CMH Ultra 0 8 E7 LU0/8/XO/D/7 696 600 00 U,000 6 7 8. A 70 90 E7 LU70/90/XO/D/7 697 6 000 00 U 0 000 6 7 8.9 A 00 00 E0 LU00/00/XO/D/0 979 0 00 00 U 0 000 86 76. A+ 0 00 E0 LU0/00/XO/D/0 980 6 900 00 U 000 7 9 70. A+ 0 00 E0 LU0/XO/D/0 98 00 00 U 000 7 9 8.7 A+ 00 0 E0 LU00/XO/D/0 996 000 00 U 000 9. A+ 6 Operating position Rated Life (h) Lucalox Superlife Elliptical Diffuse 0 00 E0 LU0/SBY/D/E0 90* 6 000 000 U 000 7 9 7.7 A+ * Not CE compliant product and will be phased out Lucalox Standard Tubular Clear 70 90 E7 LU 70/90/MO/T/E7 6 6 00 000 U 8 000 6 9 78 A+ 00 00 E0 LU00/00/MO/T/0 9767 9 600 000 U 8 000 8 07.6 A+ 0 00 E0 LU0/00/HO/T/E0 97 7 00 000 U 000 8 8 7.7 A+ 0 00 E0 LU0/00/0* 00 000 U 8 000 8 6.8 A+ 0 00 E0 LU0/T/0* 8 00 000 U 8 000 60 8 76.8 A+ 0 00 E0 LU0/HO/T/E0 MIC 90096 00 000 U 000 60 8 8. A+ 00 00 E0 LU00/HO/T/E0 970 6 00 000 U 000 60 8. A++ 00 00 E0 LU00/T/0* 678 8 000 000 U 8 000 78 8.9 A+ 000 0 E0 LU000/0 8886 0 000 00 U 000 8 79 00 A+ 6 000 0 E0 LU000/0/T/0 7 0 000 000 U 000 7 68 067. A++ * Not CE compliant product Lucalox Standard Elliptical Diffuse 70 90 E7 LU70/90/MO/D/E7 67 70 000 U 8 000 6 7 77.8 A 00 00 E0 LU00/00/MO/D/0* 9766 9 00 000 U 8 000 86 76.8 A+ 0 00 E0 LU0/00/D/0* 00 000 U 8 000 7 9 6.7 A+ 0 00 E0 LU0/D/0* 0 6 000 000 U 8 000 7 9 76. A+ 00 0 E0 LU00/D/0* 07 8 000 000 U 8 000 8. A+ 6 * Not CE compliant product Lucalox Internal Ignitor Elliptical Clear 70 90 E7 LU 70/90/MO/I/E7 609 6 00 000 U 7 00 6 7 79. A+ Lucalox Internal Ignitor Elliptical Diffuse 0 8 E7 LU0/8/MO/D/I/E7* 886** 00 000 U 000 6 7 6. A 6 70 90 E7 LU70/90/MO/D/I/E7 686 70 000 U 7 00 6 7 78. A 6 * Not CE compliant product ** Will be phased out Kolorlux Mercury Standard 0 9 E7 OT H0/7 / MIC DS* 606 800 000 0 U 6 000 0 7. B 7 80 E7 OT H80/7 / MIC DS* 699 800 000 U 0 000 6 70 90.8 B 7 E7 H/7 / MIC DS* 660 6 00 000 U 0 000 70 7.7 B 7 0 0 E0 H0/0 / MIC DS* 66 000 000 0 U 0 000 7 90 7.6 B 7 00 E0 OT H00/0 / MIC DS* 667 00 000 0 U 0 000 9 0. B 7 * Not CE compliant product, only full container order Mixed Light 60 0-0 E7 OT ML 0-0V 60W E7 GE / MIC DS* 667 00 00 VBU±0 8 000 70 76 8. D 8 0 0-0 E0 OT ML 0-0V 0W E0 GE / MIC DS* 6678 00 800 U 8 000 7 9 77. C 8 0 0-0 E7 OT ML 0-0V 0W E7 GE / MIC DS* 6677 00 800 U 8 000 7 9 77. C 8 00 0-0 E0 OT ML 0-0V 00W E0 GE /0 MIC DS* 6676 000 800 U 8 000 9. B 0 8 * Not CE compliant product, only full container order 6 7 8 76 77
Linear Fluorescent Lamps LFL LFL Linear Fluorescent Lamps 78
Linear Fluorescent Lamps The smart choice for efficient bright light The Linear Fluorescent Lamps (LFLs) still offer an attractive lighting solution for many applications from office and retail to education and industrial, delivering excellent levels of light distribution to complement directional light sources. Our wide range of T and T8 Linear Fluorescent Lamps offer benefits including long life, energy savings, low maintenance and excellent colour rendering. A choice of colour temperatures from 700 600K means we are able to supply the best possible LFL product for every application. Recent additions to our range include a new 000 hours T product. LFL Extensive range for every indoor application 8 CRI high colour rendering and high lumen maintenance Excellent light distribution complements directional light Dimmability for further cost/energy savings LFL We also offer a choice of enhanced performance products in the form of our energy saving Watt-Miser TM Lamps and high rated life LongLast TM products. LONG LIFE REDUCED MAINTENANCE COSTS WIDE RANGE OF COLOUR TEMPERATURES Watt-Miser Lamps saving LFLs Up to 0% energy savings vs. traditional LFL Short payback less than a year Exceptional lumen maintenance LongLast Lamps LFLs offering increased service life Reduced relamping costs with up to 6 000 hours rated life Reduced maintenance costs Ideal where luminaires are hard to reach 80 8
Linear Fluorescent Lamps overview High Efficiency Watt-Miser Wattages: W Colours: Warm White to Cool White : 8 Rated life: 000 h High Output Watt-Miser Wattages: 76W Colours: Warm White to Cool White : 8 Rated life: 000 (0 000) h High Efficiency LongLast Wattages: W Colours: Extra Warm White to Daylight : 8 Rated life: 0 000 h LFL High Output LongLast Wattages: 80W Colours: Warm White to Daylight : 8 Rated life: 0 000 h 000h High Efficiency Wattages: W Colours: Warm White to Daylight : 8 Rated life: 000 h 000h High Output Wattages: 80W Colours: Warm White to Daylight : 8 Rated life: 000 h LFL T Tubes Long Specfill Triphosphor Wattages: 6 8W Colours: Cool White and Daylight : 80+ Rated life: 8 000 h Specfill Standard Wattages: 6 8W Colours: Cool White and White : 60 Rated life: 8 000 h Triphosphor Wattages: 8 W Colours: Extra Warm White to Cool White : 80+ Rated life: 000 h Standard Wattages: W Colours: Warm White to Cool White : -8 Rated life: 000 h Watt-Miser Wattages: 6 W Colours: Warm White to Daylight : 80+ Rated life: 000 h Polylux XLR LongLast Wattages: 8 8W Colours: Warm White and Cool White : 80+ Rated life: 8 000 h Polylux XLR Wattages: 70W Colours: Extra Warm White to Daylight : 80+ Rated life: 000 h T Tubes Short T8 Tubes T Circline Wattages: W Colours: Warm White to Cool White : 8 Rated life: 000 h covrguard Polylux XLR Wattages: 8 8W Colour: Cool White : 80+ Rated life: 000 h Glow Starters For wattages: W Circular Tubes T8 Shatter-proof Starters 8 8
Linear Fluorescent Lamps Linear Fluorescent Lamps Initial Lumen (at C) (lm) Colour Type Rated Average Life (-hr cycle) (h) Initial Lumen (at C) (lm) Colour Type Rated Average Life (-hr cycle) (h) T Watt-Miser High Efficiency, G T LongLast High Efficiency, G LFL 9 6 FW/T/80/WM 798 0 Warm White 000 8 000 A+ 0 9 6 FW/T/80/WM 6080 0 Cool White 000 8 000 A+ 0 0 89 6 F0W/T/80/WM 6079 00 Cool White 000 8 000 A+ 0 6 9 6 F6W/T/80/WM 97 900 Warm White 000 8 000 9 A+ 0 6 9 6 F6W/T/80/WM 6078 900 Cool White 000 8 000 9 A+ 0 9 6 FW/T/80/WM 797 60 Warm White 000 8 000 6 A+ 0 9 6 FW/T/80/WM 6077 60 Cool White 000 8 000 6 A+ 0 T Watt-Miser High Output, G 9 6 FW/T/80/WM 6076 000 Cool White 000 8 000 A+ 0 6 89 6 F6W/T/80/WM 607 00 Cool White 000 8 000 9 A+ 0 6 9 6 F6W/T/80/WM 97 900 Warm White 000 8 000 A+ 0 6 9 6 F6W/T/80/WM 607 900 Cool White 000 8 000 A+ 0 7 9 6 F7W/T/80/WMP 9087 800 Cool White 000 8 0 000 A+ 0 9 6 FW/T/80/WM 97966 000 Warm White 000 8 0 000 6 A+ 0 9 6 FW/T/80/WM 607 000 Cool White 000 8 0 000 6 A+ 0 76 9 6 F76W/T/80/WM 9796 7 000 Warm White 000 8 000 8 A+ 0 76 9 6 F76W/T/80/WM 607 7 000 Cool White 000 8 000 8 A+ 0 T LongLast High Efficiency, G 9 6 FW/T/87/LL 6086 0 Extra Warm White 700 8 0 000 A+ 0 9 6 FW/T/80/LL 6087 0 Warm White 000 8 0 000 A+ 0 9 6 FW/T8/80/LL/BULK 6066 0 Warm White 000 8 0 000 A+ 0 9 6 FW/T/8/LL 6090 0 White 00 8 0 000 A+ 0 9 6 FW/T/80/LL 609 0 Cool White 000 8 0 000 A+ 0 9 6 FW/T8/80/LL/BULK 6067 0 Cool White 000 8 0 000 A+ 0 9 6 FW/T/86/LL 6088 0 Daylight 600 8 0 000 A+ 0 89 6 FW/T/87/LL 6089 00 Extra Warm White 700 8 0 000 A+ 0 89 6 FW/T/80/LL 609 00 Warm White 000 8 0 000 A+ 0 89 6 FW/T/80/LL 609 00 Cool White 000 8 0 000 A+ 0 89 6 FW/T8/80/LL/BULK 6068 00 Cool White 000 8 0 000 A+ 0 89 6 FW/T/86/LL 609 90 Daylight 600 8 0 000 A+ 0 8 9 6 F8W/T/87/LL 609 900 Extra Warm White 700 8 0 000 A+ 0 8 9 6 F8W/T/80/LL 6096 900 Warm White 000 8 0 000 A+ 0 8 9 6 F8W/T/80/LL/BULK 6069 900 Warm White 000 8 0 000 A+ 0 8 9 6 F8W/T/80/LL 60 900 Cool White 000 8 0 000 A+ 0 8 9 6 F8W/T/80/LL/BULK 6070 900 Cool White 000 8 0 000 A+ 0 8 9 6 F8W/T/86/LL 6098 700 Daylight 600 8 0 000 A+ 0 9 6 FW/T/87/LL 6099 60 Extra Warm White 700 8 0 000 8 A+ 0 9 6 FW/T/80/LL 600 60 Warm White 000 8 0 000 8 A+ 0 9 6 FW/T/8/LL 60 60 White 00 8 0 000 8 A+ 0 9 6 FW/T/80/LL 60 60 Cool White 000 8 0 000 8 A+ 0 9 6 FW/T/80/LL/BULK 607 60 Cool White 000 8 0 000 8 A+ 0 9 6 FW/T/86/LL 60 00 Daylight 600 8 0 000 8 A+ 0 T LongLast High Output, G 9 6 FW/T/80/LL 60 000 Warm White 000 8 0 000 A+ 0 9 6 FW/T/8/LL 606 000 White 00 8 0 000 A+ 0 9 6 FW/T/80/LL 6097 000 Cool White 000 8 0 000 A+ 0 9 6 FW/T/80/LL/BULK 608 70 Cool White 000 8 0 000 A+ 0 9 6 FW/T/86/LL 607 900 Daylight 600 8 0 000 A 0 9 89 6 F9W/T/80/LL 608 00 Warm White 000 8 0 000 A+ 0 9 89 6 F9W/T/80/LL 609 00 Cool White 000 8 0 000 A+ 0 9 89 6 F9W/T/80/LL/BULK 608 00 Cool White 000 8 0 000 A+ 0 9 9 6 F9W/T/80/LL 69 900 Warm White 000 8 0 000 A+ 0 9 9 6 F9W/T/8/LL 6 900 White 00 8 0 000 A+ 0 9 9 6 F9W/T/80/LL 6 900 Cool White 000 8 0 000 A+ 0 9 9 6 F9W/T/80/LL/BULK 608 900 Cool White 000 8 0 000 A+ 0 9 9 6 F9W/T/86/LL 78707 60 Daylight 600 8 0 000 A+ 0 9 6 FW/T/80/LL 60 000 Warm White 000 8 0 000 9 A+ 0 9 6 FW/T/80/LL 6 000 Cool White 000 8 0 000 9 A+ 0 9 6 FW/T/80/LL/BULK 608 000 Cool White 000 8 0 000 9 A+ 0 9 6 FW/T/86/LL 68 70 Daylight 600 8 0 000 9 A+ 0 80 9 6 F80W/T/80/LL 78708 7 000 Warm White 000 8 0 000 89 A 0 80 9 6 F80W/T/80/LL 78709 7 000 Cool White 000 8 0 000 89 A 0 80 9 6 F80W/T/80/LL/BULK 608 7 000 Cool White 000 8 0 000 89 A 0 LFL explanation For further information check the glossary F 8W / T / 86 / LL Identifies lamp as fluorescent Identifies Lamp wattage Identifies lamp type Identifies the lamp as LongLast CCTcode 87=Extra Warm White 80=Warm White 8=White 80=Cool White 86=Daylight 8 8
Linear Fluorescent Lamps Linear Fluorescent Lamps Initial Lumen (at C) (lm) Colour Type Rated Average Life (-hr cycle) (h) LFL 9 6 FW/T/80 89 00 Warm White 000 8 000 A+ 0 9 6 FW/T/80/BULK 90097 00 Warm White 000 8 000 A+ 0 9 6 FW/T/80 90 00 Cool White 000 8 000 A+ 0 9 6 FW/T/80/BULK 90098 00 Cool White 000 8 000 A+ 0 9 6 FW/T/86 9 0 Daylight 600 8 000 A+ 0 89 6 FW/T/80 907 000 Warm White 000 8 000 A+ 0 89 6 FW/T/80 9076 000 Cool White 000 8 000 A+ 0 89 6 FW/T/80/BULK 9000 000 Cool White 000 8 000 A+ 0 89 6 FW/T/86 9079 900 Daylight 600 8 000 A+ 0 8 9 6 F8W/T/80 0 760 Warm White 000 8 000 A+ 0 8 9 6 F8W/T/80 0 760 Cool White 000 8 000 A+ 0 8 9 6 F8W/T/80/BULK 908 760 Cool White 000 8 000 A+ 0 8 9 6 F8W/T/86 09 60 Daylight 600 8 000 A+ 0 9 6 FW/T/80 0 0 Warm White 000 8 000 8 A+ 0 9 6 FW/T/80 7 0 Cool White 000 8 000 8 A+ 0 9 6 FW/T/80/BULK 909 0 Cool White 000 8 000 8 A+ 0 9 6 FW/T/86 60 Daylight 600 8 000 8 A+ 0 LFL Initial Lumen (at C) (lm) Colour Type Rated Average Life (-hr cycle) (h) Initial Lumen (at C) (lm) Colour Type Rated Average Life (-hr cycle) (h) T 000h High Efficiency, G T 000h High Output, G 9 6 FW/T/80/BULK 90 860 Cool White 000 8 000 9 A+ 0 9 6 FW/T/86 907 70 Daylight 600 8 000 8 A+ 0 80 9 6 F80W/T/80 9076 7 000 Warm White 000 8 000 87 A+ 0 80 9 6 F80W/T/80 907 7 000 Cool White 000 8 000 87 A+ 0 80 9 6 F80W/T/80/BULK 90 7 000 Cool White 000 8 000 87 A+ 0 80 9 6 F80W/T/86 9070 6 60 Daylight 600 8 000 88 A 0 Initial Lumen (at C) (lm) T Miniature Specfill Triphosphor Emergency Lighting, G Colour Type Rated Average Life (-hr cycle) (h) 6. 6 F6W/T/80/SPECFILL/IND 07 00 Cool White 000 80+ 8 000 6 A 00 8 88. 6 F8W/T/80/SPECFILL/IND 0 60 Cool White 000 80+ 8 000 8 A 00 8 88. 6 F8W/T/86/SPECFILL/IND 0 0 Daylight 600 80+ 8 000 8 A 00 T 000h High Output, G T Miniature Specfill Standard Emergency Lighting, G 6. 6 F6W/T//SPECFILL/IND 007 60 Cool White 000 60 8 000 6 A 00 8 88. 6 F8W/T//SPECFILL 707 7 White 00 8 000 8 B 8 88. 6 F8W/T//SPECFILL/IND 9 7 White 00 8 000 8 B 00 8 88. 6 F8W/T//SPECFILL 70 7 Cool White 000 60 8 000 8 B 8 88. 6 F8W/T//SPECFILL/IND 90 7 Cool White 000 60 8 000 8 B 00 9 6 FW/T/80 9078 000 Warm White 000 8 000 A+ 0 9 6 FW/T/80 9077 000 Cool White 000 8 000 A+ 0 9 6 FW/T/80/BULK 90099 000 Cool White 000 8 000 A+ 0 9 6 FW/T/86 9077 900 Daylight 600 8 000 A 0 9 89 6 F9W/T/80 9078 0 Warm White 000 8 000 A+ 0 9 89 6 F9W/T/80 9079 0 Cool White 000 8 000 A+ 0 9 89 6 F9W/T/80/BULK 900 0 Cool White 000 8 000 A+ 0 9 89 6 F9W/T/86 9070 00 Daylight 600 8 000 A+ 0 9 9 6 F9W/T/80 907 80 Warm White 000 8 000 A+ 0 9 9 6 F9W/T/80 907 80 Cool White 000 8 000 A+ 0 9 9 6 F9W/T/80/BULK 900 80 Cool White 000 8 000 A+ 0 9 9 6 F9W/T/86 907 600 Daylight 600 8 000 A+ 0 9 6 FW/T/80 907 860 Warm White 000 8 000 9 A+ 0 9 6 FW/T/80 907 860 Cool White 000 8 000 9 A+ 0 T Miniature Triphosphor, G 8 88. 6 F8W/T/87/IND 7008 60 Extra Warm White 700 80+ 000 8 A 00 8 88. 6 F8W/T/80/IND 7009 60 Cool White 000 80+ 000 8 A 00 6.9 6 FW/T/87 97 970 Extra Warm White 700 80+ 000 A 86 87
Linear Fluorescent Lamps Linear Fluorescent Lamps Initial Lumen (at C) (lm) Colour Type Rated Average Life (-hr cycle) (h) T Miniature Standard, G.9 6 FW/T/ 96 0 White 00 000 B.9 6 FW/T/ 9 0 Cool White 000 60 000 B 6. 6 F6W/T/ 9 60 White 00 000 6 B 6. 6 F6W/T/ 9 60 Cool White 000 60 000 6 B 8 88. 6 F8W/T/9 77 80 Warm White 900 000 8 B 8 88. 6 F8W/T/ 776 80 White 00 000 8 B LFL 8 88. 6 F8W/T/ 77 80 Cool White 000 60 000 8 B 6.9 6 FW/T/9 97 80 Warm White 900 000 B 6.9 6 FW/T/ 99 80 White 00 000 B 6.9 6 FW/T/ 90 80 Cool White 000 60 000 B Initial Lumen (at C) (lm) Colour Type Rated Average Life (-hr cycle) (h) LFL T Circline Gx 0 6 FCW/T/80 7709 900 Warm White 000 8 000 A 0 0 6 FCW/T/80 770 900 Cool White 000 8 000 A 0 0 0 6 FC0W/T/80 77 00 Warm White 000 8 000 A 0 0 0 6 FC0W/T/80 77 00 Cool White 000 8 000 A 0 0 6 FCW/T/80 777 00 Warm White 000 8 000 6 A 0 0 6 FCW/T/80 778 00 Cool White 000 8 000 6 A 0 T8 Watt-Miser G 6 89.8 6 F6W/T8/80/WM * 6 00 Warm White 000 80+ 000 0 A 6 89.8 6 F6W/T8/80/WM 6 00 Cool White 000 80+ 000 0 A 6 89.8 6 F6W/T8/860/WM * 66 0 Daylight 600 80+ 000 0 A 99. 6 FW/T8/80/WM * 67 70 Warm White 000 80+ 000 7 A 99. 6 FW/T8/80/WM 68 70 Cool White 000 80+ 000 7 A 99. 6 FW/T8/860/WM * 69 600 Daylight 600 80+ 000 8 A 00 6 FW/T8/80/WM * 670 0 Warm White 000 80+ 000 9 A 00 6 FW/T8/80/WM 669 0 Cool White 000 80+ 000 9 A 00 6 FW/T8/860/WM * 668 0 Daylight 600 80+ 000 60 A T8 Polylux XLR LongLast G 8 89.8 6 F8W/T8/80/LL * 667 0 Warm White 000 80+ 8 000 A 8 89.8 6 F8W/T8/80/LL 666 0 Cool White 000 80+ 8 000 A 6 99. 6 F6W/T8/80/LL * 66 0 Warm White 000 80+ 8 000 A 6 99. 6 F6W/T8/80/LL 66 0 Cool White 000 80+ 8 000 A 8 00 6 F8W/T8/80/LL * 66 00 Warm White 000 80+ 8 000 67 A 8 00 6 F8W/T8/80/LL 66 00 Cool White 000 80+ 8 000 67 A * Will be phased out without direct substitute T8 Polylux XLR G 7. 6 FW/T8/80/POLYLUX 66 90 Warm White 000 80+ 000 9 B 7. 6 FW/T8/8 POLYLUX 60 90 White 00 80+ 000 9 B 7. 6 FW/T8/80/POLYLUX 9 90 Cool White 000 80+ 000 9 B 7. 6 FW/T8/860/POLYLUX 6 900 Daylight 600 80+ 000 8 B 8 89.8 6 F8W/T8/87/POLYLUX 660 0 Extra Warm White 700 80+ 000 A 8 89.8 6 F8W/T8/80/POLYLUX 69 0 Warm White 000 80+ 000 A 8 89.8 6 F8W/T8/8/POLYLUX 6 0 White 00 80+ 000 A 8 89.8 6 F8W/T8/80/POLYLUX 68 0 Cool White 000 80+ 000 A 8 89.8 6 F8W/T8/860/POLYLUX 67 0 Daylight 600 80+ 000 A 0 89.6 6 F0W/T8/80/POLYLUX 66 0 Warm White 000 80+ 000 7 A 0 89.6 6 F0W/T8/8/POLYLUX 6 0 White 00 80+ 000 7 A 0 89.6 6 F0W/T8/80/POLYLUX 6 0 Cool White 000 80+ 000 7 A 0 89.6 6 F0W/T8/860/POLYLUX 0 00 Daylight 600 80+ 000 6 A 6 99. 6 F6W/T8/87/POLYLUX 6 0 Extra Warm White 700 80+ 000 A 6 99. 6 F6W/T8/80/POLYLUX 6 0 Warm White 000 80+ 000 A 6 99. 6 F6W/T8/8/POLYLUX 6 0 White 00 80+ 000 A 6 99. 6 F6W/T8/80/POLYLUX 6 0 Cool White 000 80+ 000 A 6 99. 6 F6W/T8/860/POLYLUX 6 0 Daylight 600 80+ 000 A 8 00 6 F8W/T8/87/POLYLUX 60 00 Extra Warm White 700 80+ 000 68 A 8 00 6 F8W/T8/80/POLYLUX 69 00 Warm White 000 80+ 000 68 A 8 00 6 F8W/T8/8/POLYLUX 6 00 White 00 80+ 000 68 A 8 00 6 F8W/T8/80/POLYLUX 68 00 Cool White 000 80+ 000 68 A 8 00 6 F8W/T8/860/POLYLUX 67 000 Daylight 600 80+ 000 68 A 70 76.8 6 F70W/T8/8/POLYLUX 67 6 000 White 00 80+ 000 8 A 70 76.8 6 F70W/T8/80/POLYLUX 67 6 000 Cool White 000 80+ 000 8 A 88 89
Linear Fluorescent Lamps Linear Fluorescent Lamps Brand cross reference GE Lighting Osram Philips Sylvania T Watt-Miser High Efficiency Lumilux T HE ES Master TL HE Eco T FHE Linear Ecoline LFL FW/T/80/WM W/80 W/T/80 FW/T/80/WM W/80 W/80 W/T/80 F0W/T/80/WM 9W/80 9W/T/80 F6W/T/80/WM W/80 W/80 W/T/80 F6W/T/80/WM W/80 W/80 W/T/80 FW/T/80/WM W/80 W/T/80 FW/T/80/WM W/80 W/80 W/T/80 LFL T Watt-Miser High Output Lumilux T HO ES Master TL HO Eco T FHO Linear Ecoline FW/T/80/WM 0W/80 0W/80 FHE0W/T/80 F6W/T/80/WM W/80 FHEW/T/80 F6W/T/80/WM W/80 FHEW/T/80 F6W/T/80/WM W/80 W/80 FHEW/T/80 FW/T/80/WM 0W/80 FHE0W/T/80 Initial Lumen (at C) (lm) Colour Type Rated Average Life (-hr cycle) (h) FW/T/80/WM 0W/80 0W/80 FHE0W/T/80 F76W/T/80/WM 7W/80 FHE7W/T/80 F76W/T/80/WM 7W/80 7W/80 FHE7W/T/80 T LongLast High Efficiency Lumilux T HE XT Master TL HE 8 89.8 6 F8W/T8/80 CVG * 70 00 Cool White 000 80+ 000 A 6 99. 6 F6W/T8/80 CVG * 9 0 Cool White 000 80+ 000 A 8 00 6 F8W/T8/80 CVG * 6 00 Cool white 000 80+ 000 68 A * Will be phased out without direct substitute T8 covrguard Polylux XLR G Starter Volt (V) Rated Life (switching cycles) Series -8W, -W 0-0V /00/-W/TANDEM/IND * 0 000 67,000 Single 7-W 0-0V /800/7-W/BX 0 000 786 0 Single 7-W 0-0V /80/7-W/IND * 0 000 797,000 Series -8W, -W 0-0V /00 -W/TANDEM/BX 8 000 608 0 Series -8W, -W 0-0V /00 -W/TANDEM/IND 8 000 6086,000 Single -6W 0-0V /00-6W/UNIV/BX 8 000 6087 0 Single -6W 0-0V /00-6W/UNIV/IND 8 000 6088,000 * Will be phased out FW/T/87/LL FW/T/80/LL FW/T/8/LL FW/T/80/LL FW/T/86/LL FW/T/87/LL FW/T/80/LL FW/T/80/LL FW/T/86/LL F8W/T/87/LL F8W/T/80/LL F8W/T/80/LL F8W/T/86/LL FW/T/87/LL FW/T/80/LL FW/T/8/LL FW/T/80/LL HE XT W/80 FW/T/86/LL HE XT W/86 T LongLast High Output Lumilux T HO XT Master TL HO Xtra FW/T/80/LL FW/T/8/LL FW/T/80/LL FW/T/86/LL F9W/T/80/LL F9W/T/80/LL F9W/T/80/LL HO XT 9W/80 F9W/T/8/LL F9W/T/80/LL HO XT 9W/80 9W/80 F9W/T/86/LL HO XT 9W/86 FW/T/80/LL HO XT W/80 FW/T/80/LL HO XT W/80 FW/T/86/LL HO XT W/86 F80W/T/80/LL HO XT 80W/80 F80W/T/80/LL HO XT 80W/80 80W/80 90 9
Linear Fluorescent Lamps Brand cross reference Linear Fluorescent Lamps Brand cross reference GE Lighting Osram Philips Sylvania GE Lighting Osram Philips Sylvania T 000h High Efficiency Lumilux T HE Master TL HE T Luxline Plus FHE T Circline Lumilux T FC Master TL Circular T Circline Plus LFL FW/T/80 HE W/80 W/80 FHEW/80 FW/T/80 HE W/80 W/80 FHEW/80 FW/T/86 HE W/86 W/86 FHEW/860 FW/T/80 HE W/80 W/80 FHEW/80 FW/T/80 HE W/80 W/80 FHEW/80 FW/T/86 HE W/86 W/86 FHEW/860 F8W/T/80 HE 8W/80 8W/80 FHE8W/80 F8W/T/80 HE 8W/80 8W/80 FHE8W/80 F8W/T/86 HE 8W/86 8W/86 FHE8W/860 FW/T/80 HE W/80 W/80 FHEW/80 FW/T/80 HE W/80 W/80 FHEW/80 FW/T/86 HE W/86 W/86 FHEW/860 T 000h High Output FW/T/80 HOW/80 W/80 FHOW/T/80 FW/T/80 HOW/80 W/80 FHOW/T/80 FW/T/86 HOW/86 W/86 FHOW/T/86 F9W/T/80 HO9W/80 9W/80 FHO9W/T/80 F9W/T/80 HO9W/80 9W/80 FHO9W/T/80 F9W/T/86 HO9W/86 FHO9W/T/86 F9W/T/80 HO9W/80 9W/80 FHO9W/T/80 F9W/T/80 HO9W/80 9W/80 FHO9W/T/80 F9W/T/86 HO9W/86 9W/86 FHO9W/T/86 FW/T/80 HOW/80 W/80 FHOW/T/80 FW/T/80 HOW/80 W/80 FHOW/T/80 FW/T/86 HOW/86 W/86 FHOW/T/86 F80W/T/80 HO80W/80 80W/80 FHO80W/T/80 F80W/T/80 HO80W/80 80W/80 FHO80W/T/80 F80W/T/86 HO80W/86 80W/86 FHO80W/T/86 T Miniature Specfill Triphosphore EMERGENCY LIGHTING Lumilux T Short EL Master TL Mini Super 80 T Emergency F6W/T/80/SPECFILL 6W/80 8W/80 F6W/80/SP00 F8W/T/80/SPECFILL 8W/80 F8W/80/SP00 F8W/T/86/SPECFILL T Miniature Specfill Triphosphore EMERGENCY LIGHTING Lumilux T HO Basic T Short EL Master TL HO TL Mini Standard T Luxline Plus FHO T Emergency F6W/T//SPECFILL 6W/60 6W/ F6W//SP00 F8W/T//SPECFILL F8W/T//SPECFILL 8W/60 8W/ F8W//SP00 T Miniature Standard Basic T short T Standard FW/T/ FW/ FW/T/ LW/60 FW/ F6W/T/ F6W/ F6W/T/ L6W/60 F6W/ F8W/T/9 F8W/T/ L8W/ F8W/ F8W/T/ L8W/60 F8W/ FW/T/9 FW/9 FW/T/ FW/ FW/T/ LW/60 FW/ FCW/T/80 FCW/80 W/80 FCW/T/80 FCW/80 W/80 W/80 FC0W/T/80 FC0W/80 0W/80 FC0W/T/80 FC0W/80 0W/80 0W/80 FCW/T/80 FCW/80 W/80 W/80 FCW/T/80 FCW/80 W/80 W/80 T8 Watt-Miser Lumilux T8 ES Master TL-D Eco T8 Luxline Eco F6W/T8/80/WM 6W/80 ES F6W/T8/80/WM 6W/80 ES 6W/80 F6W/T8/860/WM FW/T8/80/WM W/80 ES FW/80 FW/T8/80/WM W/80 ES W/80 FW/80 FW/T8/860/WM FW/86 FW/T8/80/WM W/80 ES FW/80 FW/T8/80/WM W/80 ES W/80 FW/80 FW/T8/860/WM FW/86 T8 Polylux XLR LongLast Lumilux XT T8 Master TL-D Xtra F8W/T8/80/POLYLUX/LL L8W/80XT 8W/80 F8W/T8/80/POLYLUX/LL L8W/80XT 8W/80 F6W/T8/80/POLYLUX/LL L6W/80XT 6W/80 F6W/T8/80/POLYLUX/LL L6W/80XT 6W/80 F8W/T8/80/POLYLUX/LL L8W/80XT 8W/80 F8W/T8/80/POLYLUX/LL L8W/80XT 8W/80 T8 Polylux XLR Lumilux T8 Master TL-D Super 80 T8 Luxline Plus FW/T8/80/POLYLUX LW/80 W/80 FW/80 FFW/T8/8 POLYLUX FW/8 FW/T8/80/POLYLUX LW/80 W/80 FW/80 FW/T8/860/POLYLUX LW/860 FW/86 F8W/T8/87/POLYLUX L8W/87 8W/87 F8W/87 F8W/T8/80/POLYLUX L8W/80 8W/80 F8W/80 F8W/T8/8/POLYLUX L8W/8 8W/8 F8W/8 F8W/T8/80/POLYLUX L8W/80 8W/80 F8W/80 F8W/T8/860/POLYLUX L8W/86 8W/86 F8W/86 F0W/T8/80/POLYLUX L0W/80 0W/80 F0W/80 F0W/T8/8/POLYLUX F0W/8 F0W/T8/80/POLYLUX L0W/80 0W/80 F0W/80 F0W/T8/860/POLYLUX L0W/86 F0W/86 F6W/T8/87/POLYLUX L6W/87 6W/87 F6W/87 F6W/T8/80/POLYLUX L6W/80 6W/80 F6W/80 F6W/T8/8/POLYLUX L6W/8 6W/8 F6W/8 F6W/T8/80/POLYLUX L6W/80 6W/80 F6W/80 F6W/T8/860/POLYLUX L6W/86 6W/86 F6W/86 F8W/T8/87/POLYLUX L8W/87 8W/87 F8W/87 F8W/T8/80/POLYLUX L8W/80 8W/80 F8W/80 F8W/T8/8/POLYLUX L8W/8 8W/8 F8W/8 F8W/T8/80/POLYLUX L8W/80 8W/80 F8W/80 F8W/T8/860/POLYLUX L8W/86 8W/86 F8W/860 F70W/T8/8/POLYLUX L70W/8 70W/8 F70W/8 F70W/T8/80/POLYLUX L70W/80 70W/80 F70W/80 LFL 9 9
Compact Fluorescent Lamps Non-Integrated Compact Fluorescent Lamps Non-Integrated CFL Non-Integrated CFL Non-Integrated Compact Fluorescent Lamps Non-Integrated 9 9
Compact Fluorescent Lamps Non-Integrated Compact Fluorescent Lamps Non-Integrated Efficient, versatile solutions for compact spaces Compact Fluorescent Lamps (CFL) have an important role to play in terms of protecting the environment through reduced energy consumption and the resulting cut in CO emissions. In addition, the long rated life of CFL Lamps means low maintenance requirements, further reducing the total cost of ownership. Our attractive range of CFL products includes energy saving Watt-Miser Lamps and the low maintenance, extended life LongLast range. Whichever you choose, these lamps offer a versatile, high quality solution when space is at a premium, with market-leading life performance and impressive levels of energy efficiency. Wide range of colour and wattage (700 600K, 70W) Dimmability for further cost/energy savings Motion detection available with selected drivers Wide choice of models for different applications CFL Non-Integrated LONG LIFE REDUCED MAINTENANCE COSTS REDUCED CO EMISSION CFL Non-Integrated CFL Watt-Miser TM Lamps D Watt-Miser Lamps are direct replacements for standard D lamps (6//8/8W) Compatible with existing control gear for additional energy saving D shape suitable for broad range of applications ideal for circular light distribution A class energy rating % extra energy saving Market leading life performance up to 000 hours Application areas: Residential Domestic Hotels/motels/restaurants Utility areas Task lighting Emergency lighting CFL LongLast Lamps Long service life up to 0 000 hours for significantly reduced replacement and maintenance costs Double, triple and quad tube (D/E, T/E, Q/E) options Ideal light source for small fixtures and downlighters Recommended control gear list and additional technical details (data sheets) at www.gelighting.com/eu Application areas: Downlighting Corridor lighting Office buildings Hotels/motels Restaurants Retail 96 97
Compact Fluorescent Lamps Non-Integrated overview Biax S Biax S -pin : G Wattages: -7-9-W Colours: 700 600K Rated life: 0 000 h Biax S/E -pin : G7 Wattages: -7-9-W Colours: 700 600K Rated life: 0 000 h W version available in Red/ Green/Blue colours. CFL Non-Integrated CFL Non-Integrated Biax D -pin : Gd Wattages: 0--8-6W Colours: 700 600K Rated life: 000 h Biax D/E -pin : Gq Wattage: 0--8-6W Colors: 700 600K Rated life: 0 000 h Biax Q/E -pin : GXq Wattages: 7 70W Colours: 700 000K Rated life: 0 000 h Biax L -pin : G Wattages: 8 W Colours: 700 600K Rated life: 000 00 h Biax D Biax Q Biax L Biax T -pin : GXd Wattages: -8-6W Colours: 700 000K Rated life: 000 h Biax T/E -pin : GXq Wattages: -8-6--W Colours: 700 000K Rated life: 000 0 000 h D Watt-Miser : GR8, GR0q Wattages: 6 8W Colours: 700 6000K Rated life: 000 000 h Biax D : GR0q- Wattages: W Colours: 700 00K Rated life: 0 000 h Biax D Integral : GRZ0d Wattages: 8W Colours: 00K Rated life: 0 000 h Biax T D 98 99
Compact Fluorescent Lamps Non-Integrated Compact Fluorescent Lamps Non-Integrated Biax S -pin, Internal Starter Biax D -pin, Internal Starter CFL Non-Integrated G FBX/SPX7/87 76 6 700 8 0 000 07. 7. B 0 G FBX/SPX/80 766 6 000 8 0 000 07. 7. B 0 7 7 G F7BX/SPX7/87 786 700 8 0 000 6. 9. A 0 7 7 G F7BX/80 890 000 8 0 000 6. 9. A 0 7 7 G F7BX/SPX/8 769 00 8 0 000 6. 9. A 0 7 7 G F7BX/SPX/80 7660 000 8 0 000 6. 9. A 0 7 7 G F7BX/86 898 600 8 0 000 6. 9. A 0 9 60 G F9BX/87 76 600 700 8 0 000 67. A 0 9 60 G F9BX/80 899 600 000 8 0 000 67. A 0 9 60 G F9BX/SPX/8 76 600 00 8 0 000 67. A 0 9 60 G F9BX/SPX/80 76 600 000 8 0 000 67. A 0 9 60 G F9BX/86 898 600 600 8 0 000 67. A 0 9 G FBX/87 766 900 700 8 0 000 7.7 A 0 9 G FBX/80 898 900 000 8 0 000 7.7 A 0 9 G FBX/8 7666 900 00 8 0 000 7.7 A 0 9 G FBX/80 766 900 000 8 0 000 7.7 A 0 9 G FBX/86 8986 900 600 8 0 000 7.7 A 0 Biax S/E -pin, External Starter Required G7 FBX/87/P 77 6 700 8 000* 7. 9. A 0 G7 FBX/80/P 77 6 000 8 000* 7. 9. A 0 7 7 G7 F7BX/87/P 768 700 8 000* 7. 7. A 0 7 7 G7 F7BX/80/P 776 000 8 000* 7. 7. A 0 9 60 G7 F9BX/87/P 770 600 700 8 000* 7. 8.8 A+ 0 9 60 G7 F9BX/80/P 9796 600 000 8 000* 7. 8.8 A+ 0 9 60 G7 F9BX/80/P 77 600 000 8 000* 7. 8.8 A+ 0 9 G7 FBX/87/P 777 900 700 8 000* 7.. A+ 0 9 G7 FBX/80/P 979 600 000 8 000* 7.. A+ 0 9 G7 FBX/80/P 77 900 000 8 000* 7.. A+ 0 9 G7 FBX/86/P 60 900 600 8 000* 7.. A+ 0 9 G7 FBX/GREEN/G7 98 00 GREEN N/A 000* 7. N/A N/A 0 9 G7 FBX/BLUE/G7 98 0 BLUE N/A 000* 7. N/A N/A 0 9 G7 FBX/RED/G7 98 600 RED N/A 000* 7. N/A N/A 0 * Life on electronic gear h-cycle - explanation For further information check the glossary F BX / RED / 8 7 Identifies lamp as fluorescent type American standard coding of colour temperature Colour temperature XX=First digits of temperature in Kelvin - XX00K Eg. 7 is 700K Colour definition 87=Extra Warm White 80=Warm White 8=White 80=Cool White 86=Daylight 0 6 GD- F0DBX/T/87/P 708 600 700 8 000. 08..7 B 0 0 6 GD- F0DBX/T/80/P 708 600 000 8 000. 08..7 B 0 0 6 GD- F0DBX/T/80/P 706 600 000 8 000. 08..7 B 0 0 6 GD- F0DBX/T/86/P 7068 600 600 8 000. 08..7 B 0 0 6 GD- F0DBX/T/87/P 78* 600 700 8 000. 08.7 B 0 0 6 GD- F0DBX/T/80/P 78* 600 000 8 000. 08.7 B 0 0 6 GD- F0DBX/T/86/P 78* 600 600 8 000. 08.7 B 0 9 GD- FDBX/T/87/P 706 900 700 8 000. 6. A 0 9 GD- FDBX/T/80/P 707 900 000 8 000. 6. A 0 9 GD- FDBX/T/80/P 707 900 000 8 000. 6. A 0 9 GD- FDBX/T/86/P 707 900 600 8 000. 6. A 0 9 GD- FDBX/T/87/P 78* 900 700 8 000. 9 6. A 0 9 GD- FDBX/T/80/P 78* 900 000 8 000. 9 6. A 0 9 GD- FDBX/T/8/P 78** 900 00 8 000. 9 6. A 0 9 GD- FDBX/T/80/P 78* 900 000 8 000. 9 6. A 0 8 00 Gd- F8DBXT/SPX7/87 860 00 700 8 000.. B 0 8 00 Gd- F8DBXT/SPX0/80 86 00 000 8 000.. B 0 8 00 Gd- F8DBXT/SPX/8 86 00 00 8 000.. B 0 8 00 Gd- F8DBXT/SPX/80 86 00 000 8 000.. B 0 8 00 Gd- F8DBXT/SPX6/86 07 00 600 8 000.. B 0 6 0 Gd- F6DBXT/SPX7/87 0 800 700 8 000. 69.. B 0 6 0 Gd- F6DBXT/SPX0/80 7 800 000 8 000. 69.. B 0 6 0 Gd- F6DBXT/SPX/8 800 00 8 000. 69.. B 0 6 0 Gd- F6DBXT/SPX/80 800 000 8 000. 69.. B 0 6 0 Gd- F6DBXT/SPX6/86 0 70 600 8 000. 69.. B 0 * Will be phased out, change from T to T ** Will be phased out with no direct substitute Biax D/E LongLast -pin, External Starter Required 0 6 Gq- F0DBX/T/87/P 70 600 700 8 0 000**. 0 0. A 0 0 6 Gq- F0DBX/T/80/P 70 600 000 8 0 000**. 0 0. A 0 0 6 Gq- F0DBX/T/80/P 7060 600 000 8 0 000**. 0 0. A 0 0 6 Gq- F0DBX/T/87/P 787* 600 700 8 0 000**. 00. 0. A 0 0 6 Gq- F0DBX/T/80/P 788* 600 000 8 0 000**. 00. 0. A 0 9 Gq- FDBX/T/87/P 7080 900 700 8 0 000**...8 A 0 9 Gq- FDBX/T/80/P 708 900 000 8 0 000**...8 A 0 9 Gq- FDBX/T/80/P 708 900 000 8 0 000**...8 A 0 9 Gq- FDBX/T/86/P 7087 900 600 8 0 000**...8 A 0 * Will be phased out, change from T to T ** Life on electronic gear h-cycle CFL Non-Integrated Lamp s wattage Colour rendering Ra 60-69 (group B) Ra 70-79 (group A) Ra 80-89 (group B) Ra 90-99 (group A) 00 0
Compact Fluorescent Lamps Non-Integrated Compact Fluorescent Lamps Non-Integrated Biax D/E LongLast -pin, External Starter Required Biax T/E LongLast -pin with Amalgam, External Starter Required with HF gear* 8 00 Gq- F8DBX/SPX7/87/P 86 00 700 8 0 000*. 6. 8. A 0 8 00 Gq- F8DBX/SPX0/80/P 866 00 000 8 0 000*. 6. 8. A 0 8 00 Gq- F8DBX/SPX/8/P 869 00 00 8 0 000*. 6. 8. A 0 8 00 Gq- F8DBX/SPX/80/P 870 00 000 8 0 000*. 6. 8. A 0 6 0 Gq- F6DBX/SPX7/87/P 7 800 700 8 0 000*. 6 6. A 0 6 0 Gq- F6DBX/SPX0/80/P 800 000 8 0 000*. 6 6. A 0 6 0 Gq- F6DBX/SPX/8/P 8 800 00 8 0 000*. 6 6. A 0 6 0 Gq- F6DBX/SPX/80/P 6 800 000 8 0 000*. 6 6. A 0 6 0 Gq- F6DBX/SPX6/86/P 798 70 600 8 0 000*. 6 6. A 0 * Life on electronic gear h-cycle 00 GXq- FTBX/SPX7/87/APP 90 00 700 8 0 000** 9. 6.. A 0 00 GXq- FTBX/SPX0/80/APP 9 00 000 8 0 000** 9. 6.. A 0 00 GXq- FTBX/SPX/8/A/P 9 00 00 8 0 000** 9. 6.. A 0 00 GXq- FTBX/SPX/80/A/P 9 00 000 8 0 000** 9. 6.. A 0 GXq- FTBX/87/A/P 6 00 700 8 0 000** 9. 6. 7. A 0 GXq- FTBX/80/A/P 6 00 000 8 0 000** 9. 6. 7. A 0 GXq- FTBX/8/A/P 6 00 00 8 0 000** 9. 6. 7. A 0 GXq- FTBX/8/A/P 6 00 000 8 0 000** 9. 6. 7. A 0 * Life test: if HF gear used with h cycling, otherwise with h cycling **Life on electronic gear h-cycle CFL Non-Integrated Biax T -pin with Amalgam, Internal Starter 9 GXd- FTBX/87/A/P 90 900 700 8 000 9..9 6. B 0 9 GXd- FTBX/SPX0/80/A/P 966 900 000 8 000 9..9 6. B 0 9 GXd- FTBX/SPX/A/P 9 900 000 8 000 9..9 6. B 0 8 00 GXd- F8TBX/SPX7/87/A/P 9 00 700 8 000 9. 7.. B 0 8 00 GXd- F8TBX/SPX0/80/A/P 9 00 000 8 000 9. 7.. B 0 8 00 GXd- F8TBX/SPX/80/A/P 99 00 000 8 000 9. 7.. B 0 6 0 GXd- F6TBX/SPX7/87/A/P 99 800 700 8 000 9. 9.9.8 B 0 6 0 GXd- F6TBX/SPX0/80/A/P 9 800 000 8 000 9. 9.9.8 B 0 6 0 GXd- F6TBX/SPX/80/A/P 96 800 000 8 000 9. 9.9.8 B 0 Biax Q/E LongLast -pin with Amalgam, External Starter Required with HF gear* 7 7 GXq- F7QBX/87/A/P/LL *** 00 700 8 0 000** 8. 80.7 6.6 A 0 7 7 GXq- F7QBX/80/A/P/LL 0 *** 00 000 8 0 000** 8. 80.7 6.6 A 0 7 7 GXq- F7QBX/8/A/P/LL 0 *** 00 00 8 0 000** 8. 80.7 6.6 A 0 7 7 GXq- F7QBX/80/A/P/LL 0 *** 00 000 8 0 000** 8. 80.7 6.6 A 0 70 9 GXq-6 F70QBX/80/A/P/LL 08 *** 00 000 8 0 000** 8. 08. 77 A 0 70 9 GXq-6 F70QBX/8/A/P/LL 9 *** 00 00 8 0 000** 8. 08. 77 A 0 70 9 GXq-6 F70QBX/80/A/P/LL 8 *** 00 000 8 0 000** 8. 08. 77 A 0 * Life test: if HF gear used with h cycling, otherwise with h cycling ** Life on electronic gear h-cycle *** Whole range will be phased out CFL Non-Integrated Biax T/E LongLast -pin with Amalgam, External Starter Required 9 GXq- FTBX/SPX7/87/A/P 9 900 700 8 0 000** 9. 06..8 A 0 9 GXq- FTBX/SPX0/80/A/P 9 900 000 8 0 000** 9. 06..8 A 0 9 GXq- FTBX/SPX/8/A/P 00 900 00 8 0 000** 9. 06..8 A 0 9 GXq- FTBX/SPX/80/A/P 87 900 000 8 0 000** 9. 06..8 A 0 8 00 GXq- F8TBX/SPX7/87/A/P 9 00 700 8 0 000** 9. 0.7 8. A 0 8 00 GXq- F8TBX/SPX0/80/A/P 96 00 000 8 0 000** 9. 0.7 8. A 0 8 00 GXq- F8TBX/SPX/8/A/P 0 00 00 8 0 000** 9. 0.7 8. A 0 8 00 GXq- F8TBX/SPX/80/A/P 8 00 000 8 0 000** 9. 0.7 8. A 0 6 0 GXq- F6TBX/SPX7/87/A/P 9 800 700 8 0 000** 9.. 6. A 0 6 0 GXq- F6TBX/SPX0/80/A/P 97 800 000 8 0 000** 9.. 6. A 0 6 0 GXq- F6TBX/SPX/8/A/P 06 800 00 8 0 000** 9.. 6. A 0 6 0 GXq- F6TBX/SPX/80/A/P 8 800 000 8 0 000** 9.. 6. A 0 Biax L LongLast -pin, External Starter Required with HF gear* 0 6 G F0BX/80 7 00 000 8 00*.8 8.8 A 6 0 6 G F0BX/8 7 00 00 8 00*.8 8.8 A 6 0 6 G F0BX/80 7 00 000 8 00*.8 8.8 A 6 0 G FBX/80 7 800 000 8 00*.8 8.8 60. A 6 0 G FBX/8 60 800 00 8 00*.8 8.8 60. A 6 0 G FBX/80 98 800 000 8 00*.8 8.8 60. A 6 0 G FBX/86 769 0 600 8 00*.8 8.8 60. A 6 * Life test: if HF gear used with h cycling, otherwise with h cycling **Life on electronic gear h-cycle 6 0 0
Compact Fluorescent Lamps Non-Integrated Compact Fluorescent Lamps Non-Integrated Biax L -pin, External Starter Required 8 8 G F8BX/87 087 0 700 8 000*.8. 7.6 A 8 8 G F8BX/80 088 0 000 8 000*.8. 7.6 A 8 8 G F8BX/8 089 0 00 8 000*.8. 7.6 A 8 8 G F8BX/80 090 0 000 8 000*.8. 7.6 A 87 G FBX/87 8 800 700 8 000*.8 6.8. A 87 G FBX/80 800 000 8 000*.8 6.8. A 87 G FBX/8 800 00 8 000*.8 6.8. A 87 G FBX/80 800 000 8 000*.8 6.8. A 0 G FBX/80 6 800 000 8 000*.8 8.8 A+ 0 G FBX/8 66 800 00 8 000*.8 8.8 A+ CFL Non-Integrated 0 G FBX/80 67 800 000 8 000*.8 8.8 A+ 6 06 G F6BX/87 07 900 700 8 000*.8.8 6.6 A+ 6 06 G F6BX/80 68 900 000 8 000*.8.8 6.6 A+ 6 06 G F6BX/8 69 900 00 8 000*.8.8 6.6 A+ 6 06 G F6BX/80 70 900 000 8 000*.8.8 6.6 A+ 6 06 G F6BX/86 769 70 600 8 000*.8.8 6.6 A * Life on electronic gear h-cycle D Watt-Miser 6 0 GR8 F6D/8 7* 00 00 8 000 8 8.8 A 0 6 0 GR0q F6D/87/P 76* 00 700 8 000 8. A 0 6 0 GR0q F6D/8/P 77* 00 00 8 000 8. A 0 6 0 GR8 F6D/T/87/P GE HB /0 WM 8 00 700 8 000 8 8.8 A 0 6 0 GR8 F6D/T/8/P GE HB /0 WM 88 00 00 8 000 8 8.8 A 0 6 0 GR0q F6D/T/87/P GE HB /0 WM 8 00 700 8 000 8. A 0 6 0 GR0q F6D/T/8/P GE HB /0 WM 8 00 00 8 000 8. A 0 6 0 GR8 F6D/T/860/P GE HB /0 WM 80 00 6000 8 000 8 8.8 A 0 0 GR0q FD/87/P 79* 7 700 8 000 8 0.9 A 0 0 GR0q FD/8/P 806* 7 00 8 000 8 0.9 A 0 0 GR0q FD/860/P 808* 0 6000 8 000 8 0.9 A 0 0 GR0q FD/T/87/P GE HB /0 WM 8 7 700 8 000 8 0.9 A 0 0 GR0q FD/T/8/P GE HB /0 WM 8 7 00 8 000 8 0.9 A 0 0 GR0q FD/T/860/P GE HB /0 WM 8 0 6000 8 000 8 0.9 A 0 8 08 GR8 F8DT/87/P 06* 0 700 8 000 0 0.8 A 0 8 08 GR0q F8DT/87/P 07* 0 700 8 000 0 0 7 A 0 8 08 GR0q F8DT/8/P 067* 0 00 8 000 0 0 7 A 0 8 08 GR0q F8DT/80/P 08* 0 000 8 000 0 0 7 A 0 * Will be phased out without direct substitute D Watt-Miser 8 08 GR8 F8D/T/87/P GE HB /0 WM 809 0 700 8 000 0 0.8 A 0 8 08 GR0q F8D/T/87/P GE HB /0 WM 88 0 700 8 000 0 0 7 A 0 8 08 GR0q F8D/T/80/P GE HB/0 WM 80 0 000 8 000 0 0 7 A 0 8 08 GR0q F8D/T/8/P GE HB /0 WM 80 0 00 8 000 0 0 7 A 0 8 08 GR0q F8D/T/80/P GE HB /0 WM 8 0 000 8 000 0 0 7 A 0 8 0 GR0q F8DT/87/P 00* 00 700 8 000 0 0 8 A 0 8 0 GR0q F8DT/8/P 066* 00 00 8 000 0 0 8 A 0 8 0 GR0q F8D/T/87/P GE HB /0 WM 8 00 700 8 000 0 0 8 A 0 8 0 GR0q F8D/T/8/P GE HB /0 WM 8 00 00 8 000 0 0 8 A 0 8 0 GR0q F8D/T/860/P LEG HB /0 WM 8 860 6000 8 000 0 0 8 A 0 * Will be phased out, pack change from blister to hanging box Biax D 98 GR0q FD/T/87/P A LEG HB /0 88 900 700 8 0 000 0 0 6.6 A 0 98 GR0q FD/T/80/P A/T LEG HB /0 89 900 000 8 0 000 0 0 6.6 A 0 98 GR0q FD/T/8/P A LEG HB /0 80 900 00 8 0 000 0 0 6.6 A 0 98 GR0q FD/T/80/P 789 900 000 8 0 000 0 0 6.6 A 0 Biax D Watt-Miser with Integral Control Gear 8 0-0 GRZ0d FLE8WD/8 GRZ0D 8* 00 00 8 0 000 8 6 A 0 * Will be phased out without direct substitute CFL Non-Integrated 0 0
Compact Fluorescent Lamps Non-Integrated Brand cross reference Compact Fluorescent Lamps Non-Integrated Brand cross reference GE Lighting Osram Philips Sylvania GE Lighting Osram Philips Sylvania Biax S -pin Colour Temperature Dulux S Master PL-S Lynx-S Biax D -pin Colour Temperature Dulux-D Master PL-C Lynx-D CFL Non-Integrated W FBX/87 700 DULUX S W/87 PL-S W/87/P Lynx S W/87 FBX/80 000 DULUX S W/80 Lynx S W/80 7W F7BX/87 700 DULUX S 7W/87 PL-S 7W/87/P Lynx S 7W/87 F7BX/80 000 DULUX S 7W/80 Lynx S 7W/80 F7BX/8 00 DULUX S 7W/8 F7BX/80 000 DULUX S 7W/80 PL-S 7W/80/P Lynx S 7W/80 F7BX/86 600 DULUX S 7W/86 9W F9BX/87 700 DULUX S 9W/87 PL-S 9W/87/P Lynx S 9W/87 F9BX/80 000 DULUX S 9W/80 PL-S 9W/80/P Lynx S 9W/80 F9BX/8 00 DULUX S 9W/8 F9BX/80 000 DULUX S 9W/80 PL-S 9W/80/P Lynx S 9W/80 F9BX/86 600 DULUX S 9W/86 W FBX/87 700 DULUX S W/87 PL-S W/87/P Lynx S W/87 FBX/80 000 DULUX S W/80 Lynx S W/80 FBX/8 00 FBX/80 000 DULUX S W/80 PL-S W/80/P Lynx S W/80 FBX/86 600 DULUX S W/86 DULUX S 9W/Red DULUX S 9W/Green DULUX S 9W/Blue Biax S/E -pin Colour Temperature Dulux-SE Master PL-S Lynx SE W FBX/87/P 700 PL-S W/87/P Lynx SE W/87 FBX/80/P 000 PL-S W/80/P Lynx SE W/80 7W F7BX/87/P 700 DULUX S/E 7W/87 PL-S 7W/87/P Lynx SE 7W/87 F7BX/80/P 000 DULUX S/E 7W/80 PL-S 7W/80/P Lynx SE 7W/80 9W F9BX/87/P 700 DULUX S/E 9W/87 PL-S 9W/87/P Lynx SE 9W/87 F9BX/80/P 000 DULUX S/E 9W/80 Lynx SE 9W/80 F9BX/80/P 000 DULUX S/E 9W/80 PL-S 9W/80/P Lynx SE 9W/80 W FBX/87/P 700 DULUX S/E W/87 PL-S W/87/P Lynx SE W/87 FBX/87/P 000 DULUX S/E W/80 Lynx SE W/80 FBX/80/P 000 DULUX S/E W/80 PL-S W/80/P Lynx SE W/80 FBX/86/P 600 FBX/Red FBX/Green FBX/Blue 6W F6DBX/87 700 DULUX D 6W/87 PL-C 6W/87/P Lynx D 6W/87 F6DBX/80 000 DULUX D 6W/80 PL-C 6W/80/P Lynx D 6W/80 F6DBX/8 00 DULUX D 6W/8 PL-C 6W/8/P Lynx D 6W/8 F6DBXT/SPX/80 000 DULUX D 6W/80 PL-C 6W/80/P Lynx D 6W/80 F6DBXT/SPX6/86 600 DULUX D 6W/86 PL-C 6W/86/P Lynx D 6W/86 Biax D/E -pin Colour Temperature Dulux-DE Master PL-C Lynx-DE 0W F0DBX/87/P/EOL 700 DULUX D/E 0W/87 PL-C 0W/87/P Lynx DE 0W/87 F0DBX/80/P/EOL 000 DULUX D/E 0W/80 PL-C 0W/80/P Lynx DE 0W/80 F0DBX/80/P/EOL 000 DULUX D/E 0W/80 PL-C 0W/80/P Lynx DE 0W/80 W FDBX/87/P/EOL 700 DULUX D/E W/87 PL-C W/87/P Lynx DE W/87 FDBX/80/P/EOL 000 DULUX D/E W/80 PL-C W/80/P Lynx DE W/80 FDBX/80/P/EOL 000 PL-C W/80/P Lynx DE W/80 FDBX/86/P/EOL 600 Lynx DE W/860 8W F8DBX/87/P/EOL 700 DULUX D/E 8W/87 PL-C 8W/87/P Lynx DE 8W/87 F8DBX/80/P/EOL 000 DULUX D/E 8W/80 PL-C 8W/80/P Lynx DE 8W/80 F8DBX/8/P/EOL 00 DULUX D/E 8W/8 Lynx DE 8W/8 F8DBX/80/P/EOL 000 DULUX D/E 8W/80 PL-C 8W/80/P Lynx DE 8W/80 6W F6DBX/87/P/EOL 700 DULUX D/E 6W/87 PL-C 6W/87/P Lynx DE 6W/87 F6DBX/80/P/EOL 000 DULUX D/E 6W/80 PL-C 6W/80/P Lynx DE 6W/80 F6DBX/8/P/EOL 00 DULUX D/E 6W/8 PL-C 6W/8/P Lynx DE 6W/8 F6DBX/80/P/EOL 000 DULUX D/E 6W/80 PL-C 6W/80/P Lynx DE 6W/80 F6DBX/86/P/EOL 600 DULUX D/E 6W/86 Lynx DE 6W/860 Biax T -pin Colour Temperature Dulux T Plus Master PL-T Lynx-T W FTBX/87/A/P 700 PL-T W/87/P FTBX/80/A/P 000 DULUX T W/80 PL-T W/80/P FTBX/80/A/P 000 DULUX T W/80 PL-T W/80/P 8W F8TBX/87/A/P 700 DULUX T 8W/87 PL-T 8W/87/P F8TBX/80/A/P 000 DULUX T 8W/80 PL-T 8W/80/P Lynx T 8W/80 F8TBX/8O/A/P 000 DULUX T 8W/80 PL-T 8W/80/P Lynx T 8W/80 6W F6TBX/87/A/P 700 DULUX T 6W/87 PL-T 6W/87/P F6TBX/80/A/P 000 DULUX T 6W/80 PL-T 6W/80/P Lynx T 6W/80 F6TBX/80/A/P 000 DULUX T 6W/80 PL-T 6W/80/P Lynx T 6W/80 Biax T/E -pin Colour Temperature Dulux T/E Plus Master PL-T -pin Lynx- TE CFL Non-Integrated Biax D -pin Colour Temperature Dulux-D Master PL-C Lynx-D 0W F0DBX/87 700 DULUX D 0W/87 PL-C 0W/87/P Lynx D 0W/87 F0DBX/80 000 DULUX D 0W/80 PL-C 0W/80/P Lynx D 0W/80 F0DBX/80 000 DULUX D 0W/80 PL-C 0W/80/P Lynx D 0W/80 F0DBX/86 600 DULUX D 0W/86 Lynx D 0W/860 W FDBX/87 700 DULUX D W/87 PL-C W/87/P Lynx D W/87 FDBX/80 000 DULUX D W/80 PL-C W/80/P Lynx D W/80 FDBX/80 000 DULUX D W/80 PL-C W/80/P Lynx D W/80 FDBX/86 600 DULUX D W/86 Lynx D W/860 8W F8DBX/87 700 DULUX D 8W/87 PL-C 8W/87/P Lynx D 8W/87 F8DBX/80 000 DULUX D 8W/80 PL-C 8W/80/P Lynx D 8W/80 F8DBX/8 00 DULUX D 8W/8 Lynx D 8W/8 F8DBX/80 000 DULUX D 8W/80 PL-C 8W/80/P Lynx D 8W/80 F8DBX/86 600 DULUX D 8W/86 Lynx D 8W/860 W FTBX/87/A/P/EOL 700 DULUX T/E W/87 PL-T W/87/P FTBX/80/A/P/EOL 000 DULUX T/E W/80 PL-T W/80/P FTBX/8/A/P/EOL 00 FTBX/80/A/P/EOL 000 DULUX T/E W/80 PL-T W/80/P 8W F8TBX/87/A/P/EOL 700 DULUX T/E 8W/87 PL-T 8W/87/P F8TBX/80/A/P/EOL 000 DULUX T/E 8W/80 PL-T 8W/80/P Lynx TE 8W/80 F8TBX/8/A/P/EOL 00 F8TBX/80/A/P/EOL 000 DULUX T/E 8W/80 PL-T 8W/80/P Lynx TE 8W/80 6W F6TBX/87/A/P/EOL 700 DULUX T/E 6W/87 PL-T 6W/87/P F6TBX/80/A/P/EOL 000 DULUX T/E 6W/80 PL-T 6W/80/P Lynx TE 6W/80 F6TBX/8/A/P/EOL 00 F6TBX/80/A/P/EOL 000 DULUX T/E 6W/80 PL-T 6W/80/P Lynx TE 6W/80 W FTBX/87/A/P/EOL 700 DULUX T/E W/87 PL-T W/87/P FTBX/80/A/P/EOL 000 DULUX T/E W/80 PL-T W/80/P Lynx TE W/80 FTBX/8/A/P/EOL 00 06 07
Compact Fluorescent Lamps Non-Integrated Brand cross reference Compact Fluorescent Lamps Non-Integrated Brand cross reference GE Lighting Osram Philips Sylvania GE Lighting Osram Philips Sylvania Biax T/E -pin Colour Temperature Dulux T/E Plus Master PL-T p0in Lynx- TE Biax D -pin ColourTemperature PL-Q -pin Lynx-Q (GR8 base) pin CFL Non-Integrated FTBX/80/A/P/EOL 000 DULUX T/E W/80 PL-T W/80/P Lynx TE W/80 W FTBX/87/A/P/EOL 700 DULUX T/E W/87 PL-T W/87/P FTBX/80/A/P/EOL 000 DULUX T/E W/80 PL-T W/80/P Lynx TE W/80 FTBX/8/A/P/EOL 00 FTBX/8/A/P/EOL 000 DULUX T/E W/80 PL-T W/80/P Lynx TE W/80 Biax Q/E -pin Colour Temperature Dulux T/E PL-T Lynx- TE t 7W F7QBX/87/A/P/EOL 700 PL-T 7W/87/P F7QBX/80/A/P/EOL 000 PL-T 7W/80/P F7QBX/8/A/P/EOL 00 F7QBX/80/A/P/EOL 000 PL-T 7W/80/P 70W F70QBX/80/A/P/EOL 000 F70QBX/8/A/P/EOL 00 F70QBX/80/A/P/EOL 000 Biax L -pin Colour Temperature Dulux-L PL-L Lynx L & Lynx-LE 8W F8BX/87 700 DULUX L 8W/87 Lynx L 8W/87 F8BX/80 000 DULUX L 8W/80 PL-L 8W/80/P Lynx L 8W/80 F8BX/8 00 DULUX L 8W/8 PL-L 8W/8/P F8BX/80 000 DULUX L 8W/80 PL-L 8W/80/P Lynx L 8W/80 W FBX/87 700 DULUX L W/87 Lynx L W/87 FBX/80 000 DULUX L W/80 PL-L W/80/P Lynx L W/80 FBX/8 00 DULUX L W/8 PL-L W/8/P FBX/80 000 DULUX L W/80 PL-L W/80/P Lynx L W/80 W FBX/80 000 FBX/8 00 FBX/80 000 6W F6BX/87 700 DULUX L 6W/87 Lynx L 6W/87 F6BX/80 000 DULUX L 6W/80 PL-L 6W/80/P Lynx L 6W/80 F6BX/8 00 DULUX L 6W/8 F6BX/80 000 DULUX L 6W/80 PL-L 6W/80/P Lynx L 6W/80 F6BX/86 600 DULUX L 6W/86 PL-L 6W/86/P Lynx L 6W/86 0W F0BX/80 000 DULUX L 0W/80 PL-L 0W/80/P Lynx LE 0W/80 F0BX/8 00 DULUX L 0W/8 PL-L 0W/8/P Lynx LE 0W/8 F0BX/80 000 DULUX L 0W/80 PL-L 0W/80/P Lynx LE 0W/80 W FBX/80 000 DULUX L W/80 PL-L W/80/P Lynx LE W/80 FBX/8 00 DULUX L W/8 PL-L W/8/P Lynx LE W/8 FBX/80 000 DULUX L W/80 PL-L W/80/P Lynx LE W/80 FBX/8 600 DULUX L W/86 PL-L W/86/P Lynx LE W/86 6W F6D/T/87/P GE HB /0 WM 700 CFL Square 6W/87 PLQ 6W/87/P Lynx-Q 6W/87/P F6D/T/8/P GE HB /0 WM 00 CFL Square 6W/8 PLQ 6W/8/P Lynx-Q 6W/8/P F6D/T/860/P GE HB /0 WM 6000 8W F8D/T/87/P GE HB /0 WM 700 CFL Square 8W/87 Biax D -pin ColourTemperature PL-Q -pin Lynx-QE pin 0W OT F0W/D/87/P GE BL /0 700 OT F0W/D/8/P GE BL /0 00 6W F6D/T/87/P GE HB /0 WM 700 CFL Square 6W/87 PLQ 6W/87/P Lynx-QE 6W/87/P F6D/T/8/P GE HB /0 WM 00 CFL Square 6W/8 PLQ 6W/8/P Lynx-QE 6W/8/P W FD/T/87/P GE HB /0 WM 700 FD/T/8/P GE HB /0 WM 00 FD/T/860/P GE HB /0 WM 6000 8W F8D/T/87/P GE HB /0 WM 700 CFL Square 8W/87 PLQ 8W/87/P Lynx-QE 8W/87/P F8D/T/80/P GE HB/0 WM 000 PLQ 8W/80/P F8D/T/8/P GE HB /0 WM 00 CFL Square 8W/8 PLQ 8W/8/P Lynx-QE 8W/8/P F8D/T/80/P GE HB /0 WM 000 PLQ 8W/80/P Lynx-QE 8W/80/P 8W F8D/T/87/P GE HB /0 WM 700 CFL Square 8W/87 PLQ 8W/87/P Lynx-QE 8W/87/P F8D/T/8/P GE HB /0 WM 00 PLQ 8W/8/P Lynx-QE 8W/8/P F8D/T/860/P LEG HB /0 WM 6000 W FD/T/87/P A LEG HB /0 700 FD/T/80/P A/T LEG HB /0 000 FD/T/8/P A LEG HB /0 00 CFL Non-Integrated 08 09
Compact Fluorescent Lamps Integrated CFL Integrated CFL Integrated Compact Fluorescent Lamps Integrated 0
Compact Fluorescent Lamps Integrated High quality lighting with reduced energy bills Compact Fluorescent Lamps (CFL) offer an attractive and versatile lighting solution with the added benefit of low energy consumption and a reduction in CO emissions. CFLs also deliver a long rated life up to 000 hours resulting in a low total cost of ownership and reduced maintenance requirements compared with older technologies. With a wide choice of sizes, shapes and caps, we offer an extremely versatile range of integrated Compact Fluorescent Lamps, one that combines impressive energy saving benefits with high quality lighting. Integrated CFLs are suitable for a variety of applications including the home, office, retail stores and hospitality with outstanding light quality guaranteed throughout the life of the lamps. Our ranges include products with colour temperatures from 700 600K, and are available in decor incandescent sizes and look-a-like shapes (e.g. Spiral T, Stick T), with both ES and BC caps. CFL Integrated K h CFL Integrated LONG RATED LIFE FROM 6 000 TO 000 HOURS UP TO 80% ENERGY SAVINGS REDUCED CO EMISSIONS VS. OLDER TECHNOLOGIES These products offer an energy-saving alternative to incandescent bulbs across virtually all applications, with technological advances meaning they are now often even smaller than the lamps they replace. Long rated life from 6 000 to 000 hours Flicker free, instant on light with fast warm-up Environmentally friendly with low mercury content Special option high switching cycles up to 00 000 Up to 80% energy savings vs. traditional incandescent on our A energy labeled products
Compact Fluorescent Lamps Integrated overview T Mini : E7, E, B Wattages: 9 W Colours: 700 600K Rated life: 0 000 h T Mini Economy : E7, E, B Wattages: 9 W Colours: 700K Rated life: 6 000 7 000 h GLS T/T : E7, E, B Wattages: 8 0W Colours: 700 000K Rated life: 6 000 8 000 h Spherical T : E7, E, B Wattages: 7W Colours: 700 000K Rated life: 6 000 8 000 h Candle T/T : E7, E, B Wattages: 7 W Colours: 700 000K Rated life: 6 000 8 000 h Stick Decor CFL Integrated LongLast Spiral T : E7, B Wattages: 8 W Colours: 700 000K Rated life: 000 h Spiral T : E7, E, B Wattages: 8 W Colours: 700 600K Rated life: 8 000 0 000 h Globe T : E7 Wattages: 0 W Colours: 700 000K Rated life: 8 000 h Globe CFL Integrated Spiral T : E7 Wattages: 0W Colours: 700 600K Rated life: 8 000 h Spiral T High Power Factor (HPF) : E7 Wattages: W Colours: 700 600K Rated life: 0 000 h Genura : E7 Wattages: W Colours: 700 000K Rated life: 000 h Spiral Reflector
Compact Fluorescent Lamps Integrated Compact Fluorescent Lamps Integrated Stick T Mini - 0 000 hours LongLast Spiral T 000 hours CFL Integrated 9 0-0 B FLE9TBX/T/87/B 700 70 700 8 0 000 0 9 A 8 9 0-0 E7 FLE9TBX/T/87/E7 797 70 700 8 0 000 9 A 8 9 0-0 E FLE9TBX/T/87/E 798* 70 700 8 0 000 0 9 A 8 9 0-0 E7 FLE9TBX/T/80/E7 799 70 000 8 0 000 9 A 0 9 0-0 E7 FLE9TBX/T/86/E7 700* 0 600 8 0 000 9 A 0 9 0-0 E FLE9TBX/T/86/E 78* 0 600 8 0 000 0 9 A 0 0-0 E7 FLETBX/T/87/E7 77 90 700 8 0 000 A 8 0-0 B FLETBX/T/87/B 78 90 700 8 0 000 A 8 0-0 E FLETBX/T/87/E 796 90 700 8 0 000 A 8 0-0 E7 FLETBX/T/80/E7 700 90 000 8 0 000 A 0 0-0 E7 FLETBX/T/86/E7 7 60 600 8 0 000 A 8 0-0 E FLETBX/T/86/E 70 60 600 8 0 000 A 0 0-0 E FLETBX/T/87/E 8986* 90 700 8 0 000 A 0 0-0 E7 FLETBX/T/87/E7 8986* 80 700 8 0 000 A 0 0-0 E7 FLETBX/T/87/E7 76 80 700 8 0 000 A 8 0-0 E7 FLETBX/T/80/E7 77 80 000 8 0 000 A 0 0-0 E7 FLETBX/T/86/E7 776 80 600 8 0 000 A 0 0 0-0 E7 FLE0TBX/T/87/E7 779 8 700 8 0 000 6 8 A 8 6 0 0-0 B FLE0TBX/T/87/B 780 8 700 8 0 000 8 A 8 0 0-0 E7 FLE0TBX/T/80/E7 78 000 8 0 000 6 8 A 0 0 0-0 E7 FLE0TBX/T/86/E7 78 600 8 0 000 6 8 A 0 7 0-0 B FLEQBX/T/87/B 79* 00 700 8 0 000 A 8 8 0-0 E7 FLEQBX/T/87/E7 7 00 700 8 0 000 A 8 8 0-0 E7 FLEQBX/T/80/E7 78 00 000 8 0 000 A 8 Stick T Mini Economy - 7 000 hours 9 0-0 E7 FLEDBX/T/87/E7 77* 600 700 8 7 000 0 A 0 9 0-0 E7 FLEDBX/T/87/E7 0* 600 700 8 7 000 0 A 8 0 0-0 E7 FLETBX/T/87/E7 708 80 700 8 7 000 6 A 0 0 0-0 E7 FLE0TBX/T/87/E7 * 700 8 7 000 9 A 8 0 0 0-0 E7 FLE0TBX/T/87/E7 7 700 8 7 000 9 A 0 * Will be phased out 8 0-0 E7 FLE8HLX/T/87/E7 76 70 700 8 000 88 8 A 8 0-0 B FLEHLX/T/87/B 780* 70 700 8 000 97. A 6 0-0 E7 FLEHLX/T/87/E7 7800 70 700 8 000 98. A 6 0-0 E7 FLEHLX/T/87/E7 790 90 700 8 000 0. A 6 0-0 E7 FLEHLX/T/80/E7 77* 90 000 8 000 0. A 6 0 0-0 E7 FLE0HLX/T/87/E7 79 0 700 8 000 0 6 0 A 6 0-0 E7 FLEHLX/T/87/E7 79* 00 700 8 000 7 6 A 6 Spiral T 8 000-0 000 hours 8 0-0 E FLE8HLX/T/87/E 867 70 700 8 8 000 9 6 8 A 8 8 0-0 E7 FLE8HLX/T/87/E7 868 70 700 8 8 000 90 6 8 A 0 6 8 0-0 E FLE8HLX/T/86/E 86 0 600 8 8 000 9 6 8 A 8 8 0-0 E7 FLE8HLX/T/86/E7 86 0 600 8 8 000 90 6 8 A 8 6 0-0 E FLEHLX/T/87/E 869 7 700 8 0 000 0 6 A 6 7 0-0 E7 FLEHLX/T/87/E7 860 7 700 8 0 000 00 6 A 6 8 0-0 B FLEHLX/T/87/B 86 7 700 8 0 000 99 6 A 6 9 0-0 E7 FLEHLX/T/86/E7 86 66 600 8 0 000 00 6 A 0 8 0-0 E FLEHLX/T/86/E 9009 66 600 8 0 000 0 6 A 0 7 0-0 E7 FLEHLX/T/86/E7 866 900 600 8 0 000 07 0 A 0 7 0-0 E7 FLEHLX/T/87/E7 86 90 700 8 0 000 07 0 A 0 7 0-0 B FLEHLX/T/87/B 86 90 700 8 0 000 06 0 A 6 9 0-0 E7 FLEHLX/T/87/E7 7* 90 700 8 0 000 07 0 A 8 8 0-0 E7 FLEHLX/T/87/E7 89866* 90 700 8 0 000 07 0 A 0 8 0 0-0 E7 FLE0HLX/T/87/E7 86 0 700 8 0 000 08 9 A 6 8 0 0-0 B FLE0HLX/T/87/B 86* 0 700 8 0 000 07 9 A 0 9 0 0-0 E7 FLE0HLX/T/80/E7 866 00 000 8 0 000 08 9 A 6 8 0 0-0 E7 FLE0HLX/T/86/E7 867 00 600 8 0 000 08 9 A 6 8 0 0-0 E7 FLE0HLX/T/87/E7 89868* 0 700 8 0 000 08 9 A 0 8 0-0 E7 FLEHLX/T/87/E7 868 0 700 8 0 000 60 A 0 8 0-0 B FLEHLX/T/87/B 869 0 700 8 0 000 60 A 0 9 0-0 E7 FLEHLX/T/80/E7 860 80 000 8 0 000 60 A 6 8 0-0 E7 FLEHLX/T/86/E7 86 80 600 8 0 000 60 A 6 8 * Will be phased out CFL Integrated - explanation For further information check the glossary FLE 8 HLX / T / 87 / E E/E7/B/ B Identifies the lamp cap FLE Identifies as Fluorescent Electronic (Screw-in lamp) 8 Identifies lamp wattage T/T/T/T refers to the size of the tube HLX Identifies as the lamp type DBX = Double-Biax Stick (U) TBX = Triple-Biax Stick (U) QBX = Quad-Biax Stick (U) HLX = Heliax (Spiral) SPH = Spherical GG = Globe 87 Colour definition 87=Extra Warm White 80=Warm White 8=White 80=Cool White 86=Daylight 6 7 8 9 0 6 7 8 9 6 7
Compact Fluorescent Lamps Integrated Compact Fluorescent Lamps Integrated Spiral T 8 000-0 000 hours Spherical T 8 000 hours 0-0 E7 FLEHLX/T/87/E7 8976 80 700 8 8 000 0 A 0 0-0 E FLESPH/T/87/E 789* 0 700 8 8 000 96 A 8 CFL Integrated 0-0 E7 FLEHLX/T/86/E7 8970* 60 600 8 8 000 A 0 0 0-0 E7 FLE0HLX/T/87/E7 8978* 00 700 8 8 000 9 0 A 0 0 0-0 E7 FLE0HLX/T/86/E7 8979* 600 8 8 000 9 0 A 0 0 0-0 E7 FLE0HLX/T/80/E7 90006 00 000 8 0 000 7 9 0 A 0 0 0-0 E7 FLE0HLX/T/87/E7 900066 00 700 8 0 000 7 9 0 A 0 0 0-0 E7 FLE0HLX/T/86/E7 90007 600 8 0 000 7 9 0 A 0 0-0 E7 FLEHLX/T/87/E7 90006 0 700 8 0 000 9 A 0 0-0 E7 FLEHLX/T/86/E7 90007 80 600 8 0 000 9 A 0 0-0 E7 FLEHLX/T/87/E7 897* 700 700 8 8 000 9.7 A 0 0-0 E7 FLEHLX/T/86/E7 897* 60 600 8 8 000 9.9 A 0 Spiral T High Power Factor (HPF) 0 000 hours 0-0 E7 FLEHLX/T/87E7/HPF 9006 00 700 8 0 000 7 66 A 6 GLS T/T 6 000 hours 8 0-0 E FLE8GLS/T/87/E 8878* 70 700 80 6 000 0.. 8 A 8 6 8 0-0 E7 FLE8GLS/T/87/E7 8880* 70 700 80 6 000 00. 8 A 8 0-0 E FLEGLS/T/87/E 8877* 6 700 80 6 000. 6 A 6 6 0-0 E7 FLEGLS/T/87/E7 8809* 6 700 80 6 000 0 6 A 6 7 0-0 E7 FLEGLS/T/87/E7 8876* 80 700 80 6 000 6 A 6 8 0-0 B FLEGLS/T/87/B 887* 80 700 80 6 000 0 6 A 6 GLS T/T 8 000 hours 9 0-0 E FLEGLS/T/87/E 9* 6 700 8 8 000 0. A 6 6 0-0 E7 FLEGLS/T/87/E7 97* 6 700 8 8 000 07 A 6 8 0-0 B FLEGLS/T/87/B 96* 6 700 8 8 000 06 A 6 0 0-0 E7 FLEGLS/T/87/E7 77* 80 700 8 8 000 8 60 A 6 6 0-0 B FLEGLS/T/87/B 769* 80 700 8 8 000 7 60 A 6 6 0 0-0 E7 FLE0GLS/T/87/E7 77* 60 700 8 8 000 6 9 A 6 Spherical T 6 000 hours 0-0 B FLESPH/T/87/B 790* 0 700 8 8 000 9 A 8 7 0-0 E FLE7SPH/T/87/E 98* 0 700 8 8 000 96 7 A 8 7 0-0 B FLE7SPH/T/87/B 9* 0 700 8 8 000 9 7 A 8 7 0-0 E7 FLE7SPH/T/87/E7 9* 0 700 8 8 000 9 7 A 8 Candle T/T 6 000-8 000 hours 7 0-0 E FLE7CDL/T/87/E 7677* 00 700 80 6 000 08 7 7 A 8 7 0-0 B FLE7CDL/T/87/B 8886* 00 700 80 6 000 0 7 7 A 0 6 7 0-0 E FLE7CDL/T/80/E 7* 00 000 80 6 000 08 7 7 A 0 0-0 E FLECDL/T/87/E 7698* 80 700 80 6 000 0 A 6 7 7 0-0 E FLE7CDL/T/87/E 9* 0 700 8 8 000 0 7 7 A 8 7 0-0 E7 FLE7CDL/T/87/E7 99* 0 700 8 8 000 0 7 7 A 8 8 7 0-0 B FLE7CDL/T/87/B 9* 0 700 8 8 000 0 7 7 A 0 6 7 0-0 E FLE7CDL/T/80/E 9* 0 000 8 8 000 0 7 7 A 0 9 7 0-0 E FLE7CDL/T/87/E 99* 0 700 8 8 000 0 7 7 A 0 9 9 0-0 E FLE9CDL/T/87/E 77* 0 700 8 8 000 7 9 A 8 9 9 0-0 E FLE9CDL/T/87/E 77* 0 700 8 8 000 7 9 A 8 9 9 0-0 E FLE9CDL/T/87/E 66* 0 700 8 8 000 7 9 A 8 9 0-0 E7 FLE9CDL/T/87/E7 76* 0 700 8 8 000 0. 7 9 A 8 9 0-0 E7 FLE9CDL/T/87/E7 66* 0 700 8 8 000 0. 7 9 A 8 9 0-0 B FLE9CDL/T/87/B 767* 0 700 8 8 000. 7 9 A 8 0 9 0-0 B FLE9CDL/T/87/B 76* 0 700 8 8 000 09. 7 9 A 8 6 Globe T 8 000 hours 0-0 E7 FLEGG/87/E7 96776* 80 700 80 8 000 6 9 A 6 0 0-0 E7 FLE0GG/87/E7 77* 60 700 8 8 000 89 9 A 6 0 0-0 E7 FLE0GG/80/E7 9679* 700 80 8 000 7 0 0 A 6 0 0-0 E7 FLE0GG/87/E7 96780* 700 80 8 000 89 9 A 6 0-0 E7 FLEGG/87/E7 7* 7 700 8 8 000 0 00 A 6 * Will be phased out CFL Integrated 8 0-0 B FLESPH/T/87/B 888* 00 700 80 6 000 88 A 8 7 0-0 E FLE7SPH/T/87/E 888* 0 700 80 6 000 00 7 A 8 8 7 0-0 B FLE7SPH/T/87/B 888* 0 700 80 6 000 88 7 A 8 * Will be phased out Candela (Cd) Beam Angle ( ) Reflector Genura R80 000 hours 0-0 E7 EFLW/87/R80/E7 87* 80 700 70 00 80 000 0 8.0 B 6 0-0 E7 EFLW/80/R80/E7 96* 80 700 70 00 80 000 0 8.0 B 6 * Will be phased out 6 7 8 9 0 6 7 8 9 0 8 9
Halogen Lamps Halogen Lamps Halogen Halogen Halogen Lamps 0
Halogen Lamps The smart choice for instant bright white light Our Halogen Lamp family encompasses a wide selection of low/ mains voltage reflectors, capsule, linear and tubular lamps, plus a range of retrofit decor products offering a direct replacement for traditional Incandescent Lamps all delivering optimal colour rendering. Up to 0% energy savings vs. conventional lamps Instant on, full light output at start-up Crisp white light, CCT up to 000K 00% dimmable for additional cost savings Outstanding colour rendering, close to natural light (00%CRI) Environmentally friendly with no mercury or lead 00% DIMMABLE FOR ADDITIONAL COST SAVINGS UP TO 0% ENERGY SAVINGS VS. CONVENTIONAL LAMPS OUTSTANDING COLOUR RENDERING, CLOSE TO NATURAL LIGHT (00%CRI) MR6 ranges Halogen Our MR6 Halogen Reflector Lamps feature special technologies including patented GE reflector coating and multiple layers of a very durable, thin interference film to deliver more light for the same power input and outstanding colour rendering throughout a working rated life of up to 6 000 hours. Halogen Decor HaloGLS Our Decor range is available in a choice of styles (GLS, candle, spherical, reflector) and bases to enable immediate retrofit replacement of traditional lamps and deliver the immediate benefits of instant-on, crisp white light plus full compatibility with dimming switches.! From September 06 a new European Ecodesign regulation will enter into force, which will phase out all mains voltage halogen reflectors and also part of the low voltage reflectors. After this date only the high performing low voltage Halogen Reflector Lamps can be placed on the EU market. You can find various LED lamp alternatives for all the impacted halogen reflector types.
Halogen Lamps overview MR : GU Wattages: W Volts: V Rated life: 000 00 h Precise ConstantColor MR6 : GU. Wattages: 0 7W Volts: V Rated life: 000 6 000 h Precise ConstantColor MR6 IR : GU. Wattages: 0 W Volts: V Rated life: 000 h Precise Bright 000 MR6 : GU. Wattages: 0 0W Volts: V Beam Spread: 8 60 Rated life: 000 h Precise MR6 IR : GU. Wattages: 0 W Volts: V Rated life: 000 h MR6 Start : GU. Wattages: 0 0W Volts: V Rated life: 000 h Linear 7 mm : R7s Wattages: 0 0W Volts: 0, 0V Rated life: 000 h Linear 78 mm : R7s Wattages: 00W Volts: 0, 0V Rated life: 000 h Linear - High Watt : R7s Wattages: 000 000W Volts: 0, 0V Rated life: 000 h Linear AR Aluminium Reflector : G Wattages: 7W Volts: V Rated life: 000 000 h Low Voltage Reflectors GLS : E7, B Wattages: 0 00W Volts: 0, 0V Rated life: 000 h Candle : E, E7, B, B Wattages: 0 W Volts: 0, 0V Rated life: 000 h Spherical : E, B, E7, B Wattages: 0 W Volts: 0, 0V Rated life: 000 h Halogen MR6 Mains Alutech : GU0 Wattages: 0 0W Volts: 0, 0V Rated life: 000 h MR6 Mains Alutech - Coloured : GU0 Wattages: 0W Volts: 0V Rated life: 00 h PAR Reflector 6, 0,, 0 : E7 Wattages: 0 00W Volts: 0, 0V Rated life: 000 000 h Reflector : E, E7 Wattages: 8 70W Rated life: 000 h Halogen Mains Voltage Reflectors Decor Mains Voltage sule G9 : G9 Wattages: 0 W Volts: 0, 0V Rated life: 000 000 h Low voltage capsule Transversal Filament : G or GY6. Wattages: 00W Volts: 6,, V Rated life: 00 000 h Low voltage capsule Axial Filament : G or GY6. Wattages: 0 00W Volts: 6, V Rated life: 000 000 h Tubular T8 : E0 Wattage: 000 Volts: 0, 0V Rated life: 000 h sules Tubular
Halogen Lamps Halogen Lamps Candela (cd) Beam Angle ( ) Open/Closed Precise ConstantColor MR6 0 GU. BAB/CG V CE 9960* 0 7 0 900 000 0 6 0. B 0 closed GU. FMW/CG V CE 996* 0 000 0 000 000 0 6 8. B 0 closed 0 GU. FNV/CG V CE 996* 70 80 00 6 000 0 6. B 0 closed 0 GU. EXN/CG V CE 996* 760 00 0 00 6 000 0 6. B 0 closed 0 GU. EXZ/CG V CE 996* 70 900 00 6 000 0 6. B 0 closed 7 GU. EYC/CG V CE 9966* 00 000 00 000 0 6 76.9 C 0 closed * Will be phased out Candela (cd) Beam Angle ( ) Open/Closed Precise Bright 000 MR6 0 GU. M69/BAB 88 0 80 6 900 000 0.7 6 0.9 B 0 open 0 GU. M69/BAB/CG 88 0 0 6 900 000 0.7 0. 0.9 C 0 closed 6 Halogen MR Candela (cd) Beam Angle ( ) 0 GU M/FTC/CG 90067 0 80 0 800 000. 0. C 0 closed 0 GU M6/FTD/CG 9006 70 90 6 800 000. 0.6 B 0 closed 0 GU FTD/M6/CG 700 0 90 6 900 000. 0. C 0 closed GU M66/FTF/CG 967* 0 070 900 00. 8. C 0 closed GU M66/FTF/CG 9006 0 070 0 900 000. 0 8. B 0 closed GU FTF/M99/CG 70* 0 6 900 000. 0 7. D 0 closed * Will be phased out Precise ConstantColor MR6 IR 0 GU. Q0MR6HIR/CCG6 CE 9968* 00 000 6 900 000 0 6.9 B 0 closed GU. QMR6HIR/CCG6 CE 996* 860 00 6 000 000 0 6 0. B 0 closed Precise MR6 IR 0 GU. MR6 IR 0W V FL 7767* 70 000 6 900 000 0 0,. B 0 closed * Will be phased out Open/Closed GU. M8/FMW 889 0 90 6 900 000 0.7 6 7. B 0 open GU. M8/FMW/FL/CG 9067 70 00 6 900 000 0,7 6.0 C 0 closed 6 0 GU. M8/EXN 88 70 0 6 900 000 0.7 6.9 B 0 open 0 GU. M0/EXZ/CG 887 67 70 8 900 000 0.7 0..9 C 0 closed 6 0 GU. M8/EXN/CG 889 680 00 6 900 000 0.7 0..9 C 0 closed 6 0 GU. M80/FNV/CG 888 70 90 60 900 000 0.7 0..9 B 0 closed 6 0 GU. M80/FNV 88 770 070 60 900 000 0.7 6.9 B 0 open MR6 Start 0 GU. M68/ESX/CG/EC 80 0 0 900 000 0 6. B 0 closed 7 0 GU. M69/BAB/CG/EC 8006 0 0 6 900 000 0 6. B 0 closed 7 0 GU. M69/BAB/EC 8000 00 6 800 000 0 6. B 0 open 8 GU. M8/FMW/EC 800 0 9 6 900 000 0 6 7. C 0 open 8 GU. M8/FMW/CG/EC 8007 0 80 6 900 000 0 6 7. C 0 closed 7 0 GU. M9/EXT/CG/EC 80 67 8 0 900 000 0 6.7 C 0 closed 7 0 GU. M0/EXZ/CG/EC 96 680 700 900 000 0 6. C 0 closed 7 0 GU. M8/EXN/CG/EC 80 680 0 6 900 000 0 6.8 C 0 closed 7 0 GU. M8/EXN/EC 800 680 00 6 900 000 0 6.7 C 0 open 8 0 GU. M80/FNV/CG/EC 96 680 60 900 000 0 6 C 0 closed 7 0 GU. M8/EXN/CG 009 680 N/A 6 900 000 0 6.8 C 96 closed 7 0 GU. M8/EXN/EC 9796 680 N/A 6 N/A 000 0 6.8 C 0 closed 9 Halogen - explanation For further information check the glossary M6 / FTD / CG / A / FL Class M Numerical index, industry code specifying lamp type FTD - ANSI code Industry code specifying lamps type defined by the American National Standard Institute A - A-line (GLS shape) C - Candle Shape S - Spherical Shape FL - Flood Beam Angle SP - Spot Beam Angle CG - Closed design 6 7 8 9 6 7
Halogen Lamps Halogen Lamps Candela (cd) Beam Angle ( ) 0 G AR 0WV FL 0767 0 00 900 000 67. D 0 0 GU. M8/EXN/CG/AL 88 680 800 6 900 000 0 6. C 0 0 0 GU0 Q0MR6/0/FL 0898 90 00 6 700 000 0.6 D 0 0 GU0 QMR6/0/FL 0896 00 00 6 700 000.6 D 0 0 0 GU0 Q0MR6/0/FL 979 0 600 6 700 000 0.8 D 0 0 0 GU0 Q0MR6/CD/0/FL 67679 0 N/A 6 800 000 0 D 0 0 GU0 Q0MR6/0/FL 089 90 00 6 700 000 0.8 D 0 0 GU0 QMR6/0/FL 087 00 00 6 700 000 6. D 0 0 0 GU0 Q0MR6/0/FL 970 0 600 6 700 000. D 0 Halogen AR - Aluminium Reflector Mains Voltage sule G9 0 0 G9 SHORTG9 0W CL 0V 98 800 000. D 0 7 MR6 Mains Alutech 0 0 G9 SHORTG9 0W CL 0V 98 800 000. D 0 7 0 G9 SHORTG9 W CL 0V 9778* 60 800 000 D 0 7 0 G9 SHORTG9 W CL 0V 9779 60 800 000 D 0 7 0 G9 SHORTG9 W CL 0V 66 60 800 000 D 0 7 * Will be phased out MR6 Mains Alutech Coloured Colour Candela (cd) Beam Angle ( ) 0 0 GU0 Q0MR6/0/FL 99* Blue 600 6 700 00. D 0 0 0 GU0 Q0MR6/0/FL 00* Yellow 600 6 700 00. D 0 * Will be phased out Candela (cd) Beam Angle ( ) Low Voltage sule - Transversal Filament 0 6 G M9/Q0 G** 70* 80 800 00 9. B 0 8 0 6 G M9/Q0 G** 90069 80 000 00 8. B 0 8 G M9/H G 99 60 800 000 9. B 0 8 0 G M/H0 G 67 0 800 000 9 0.8 C 0 8 0 G M/Q0 G 9006 00 00 0 9 0.9 B 0 8 0 G M7/Q0 G 7* 80 900 000 9.7 C 0 8 GY6. M9/Q/GY6. 708 0 900 000 8. C 0 8 0 GY6. M/Q0 GY6. 70 90 900 000.9 C 0 8 7 GY6. M/Q7/GY6. 68 0 900 000 8.6 D 0 8 00 GY6. M8/Q00 GY6. 676 00 900 000 0. C 0 8 00 GY6. M67/Q00 GY6. V 66 000 900 000 0.7 D 0 8 Low Voltage sule - Axial Filament 0 G Q0T,/V G 90069 0 800 000 9.6 B 0 9 Halogen PAR Reflector 0 0 E7 0PAR0/0/FL 06 0 000 800 000 6. 9 0. D 7 0 E7 7PAR/0/FL 96* 670 00 800 000 8 08 76 D 6 7 0 E7 7PAR0/0/FL 09* 60 000 0 800 000 97 90. 7. D 6 7 0 E7 7PAR0/0/SP 067 60 6 00 0 800 000 97 90. 7. D 6 7 0 E7 7PAR0/0/FL 06 60 000 0 800 000 97 90. 7. D 6 00 0 E7 00PAR0/0/FL 8* 980 00 0 800 000 97 90. 00.7 D * Will be phased out 0 G M7/Q0 G 90069 80 900 000 9.7 C 0 9 0 GY6. M76/Q0/GY6. 7 00 900 000.8 C 0 9 0 G Q0T,/V G 90068 0 900 000 9. B 0 9 0 GY6. Q0T/V GY6. 696 00 900 000 0.8 C 0 9 GY6. M7/Q/GY6. 70 600 900 000. B 0 9 GY6. QT/V GY6. 699 600 900 000.7 C 0 9 0 GY6. M7/Q0/GY6. 70 900 900 000 8. C 0 9 0 GY6. Q0T/V GY6. 700 900 900 000.9 C 0 9 7 GY6. M7/Q7/GY6. 68 0 900 000 0. C 0 9 00 GY6. M80/Q00/GY6. 66 0 900 000 0.7 D 0 9 * Will be phased out ** Projector lamp 6 7 8 9 8 9
Halogen Lamps Halogen Lamps Linear 78mm HaloGLS Halogen 00 0 R7s K C00W 0V R7S 78MM 69 800 900 000 8 80. 0. D 0 00 0 R7s K C00W 0V R7S 78MM 760* / 6 800 900 000 8 80. 0. D 0 Linear 7mm 0 0 R7s K C0W 0V R7S 7MM 6967 7 000 000 000 0 9 9. D 0 00 0 R7s K9 C00W 0V R7S 7MM 6968 000 000 000 8 9 0.6 D 0 0 0 R7s K C0W 0V R7S 7MM 6970 7 000 000 000 8 9. D 0 00 0 R7s K9 C00W 0V R7S 7MM 697 000 000 000 8 9.7 D 0 0 0 R7s K C0W 0V R7S 7MM 697 0 900 000 8.8 9 6.6 D 0 0 0 R7s K C0W 0V R7S 7MM 697 0 900 000 8.8 9 8 D 0 * Will be phased out Linear - High Watt 000 0 R7s K 000W 0V R7S 89MM BX 980 000 000 000 0 90. 008 D 0 000 0 R7s K 000W 0V R7S 89MM BX 98 000 000 000 0 90. 08.9 D 0 000 0 R7s K0 000W 0V R7S MM BX 7 000 000 000 6 980. D 6 000 0 R7s K0 000W 0V R7S MM BX 7 000 000 000 6 89 00 D 6 00 0 R7s K 00W 0V R7S MM BX 98 000 000 000 0. 9. D 0 00 0 R7s K 00W 0V R7S MM BX 987 000 000 000 0. 0. D 0 000 0 R7s K8 000W 0V R7S MM BX 0886 000 000 000 0. 996. D 0 70 0 B 70W HALO A CL B 0V 676 00 900 000 0 89. 7. D 8 6 70 0 E7 70W HALO A CL E7 0V 66 00 900 000 0 89. 7. D 0 7 70 0 E7 70W HALO A CL E7 0V 79 00 900 000 0 89. 7. D 8 7 70 0 B 70W HALO A CL B 0V 999 00 800 000 0 89. 7. D 0 6 00 0 E7 00W HALO A CL E7 0V 976 800 900 000 0 89. 0.6 D 0 7 00 0 E7 00W HALO A CL E7 0V 97 800 900 000 0 89. 0. D 8 7 00 0 B 00W HALO A CL B 0V 97 800 900 000 0 89. 0. D 8 6 00 0 B 00W HALO A CL B 0V 977 800 800 000 0 89. 0.6 D 0 6 HaloCandle 0 0 E 0W HALO C CL E 0V 980 900 000 6 00. D 0 8 0 0 E 0W HALO C CL E 0V 9898 0 900 000 6 00.7 D 0 8 0 E W HALO C CL E 0V 767 60 900 000 6 00. D 0 8 0 0 E7 0W HALO C CL E7 0V 9896 0 900 000 6 00.7 D 0 9 0 E7 W HALO C CL E7 0V 767 60 900 000 6 00. D 0 9 0 0 E 0W HALO C CL E 0V 9899 900 000 6 00. D 8 0 0 E 0W HALO C CL E 0V 989 0 900 000 6 00.6 D 8 0 E W HALO C CL E 0V 7669 60 900 000 6 00.7 D 8 0 0 E7 0W HALO C CL E7 0V 989 0 900 000 6 00.6 D 9 0 E7 W HALO C CL E7 0V 7668 60 900 000 6 00.7 D 9 0 0 B 0W HALO C CL B 0V 989 0 900 000 6 00.6 D 0 0 B W HALO C CL B 0V 767 60 900 000 6 00.7 D 0 0 0 B 0W HALO C CL B 0V 9800 900 000 6 00. D 0 0 B 0W HALO C CL B 0V 989 0 900 000 6 00.6 D 0 B W HALO C CL B 0V 7670 60 900 000 6 00.7 D 0 Halogen HaloGLS HaloSpherical 0 0 B 0W HALO A CL B 0V 986 0 800 000 0 89..6 D 8 0 0 E7 0W HALO A CL E7 0V 986 0 800 000 0 89..7 D 0 0 0 E7 0W HALO A CL E7 0V 9806 0 800 000 0 89..6 D 8 0 B W HALO A CL B 0V 67 60 800 000 0 89..7 D 8 0 E7 W HALO A CL E7 0V 66 60 800 000 0 89.. D 0 0 E7 W HALO A CL E7 0V 79 60 800 000 0 89..7 D 8 0 B W HALO A CL B 0V 66 60 800 000 0 89.. D 0 0 B W HALO A CL B 0V 699 80 900 000 0 89. 6. D 8 0 E7 W HALO A CL E7 0V 699 80 900 000 0 89. D 0 0 E7 W HALO A CL E7 0V 696 80 900 000 0 89. 6. D 8 0 0 E 0W HALO S CL E 0V 9890 900 000 78. D 0 0 0 E 0W HALO S CL E 0V 988 0 900 000 78.7 D 0 0 E W HALO S CL E 0V 76 60 900 000 78. D 0 0 0 E7 0W HALO S CL E7 0V 9888 900 000 78. D 0 0 0 E7 0W HALO S CL E7 0V 988 0 900 000 78.7 D 0 0 E7 W HALO S CL E7 0V 76 60 900 000 78. D 0 0 0 E 0W HALO S CL E 0V 988 900 000 78. D 0 0 E 0W HALO S CL E 0V 9878 0 900 000 78.6 D 6 7 8 9 0 0
Halogen Lamps Halogen Lamps HaloSpherical 0 E W HALOS CL E 0V 768 60 900 000 78.7 D 0 0 E7 0W HALO S CL E7 0V 9877 0 900 000 78.6 D 0 E7 W HALOS CL E7 0V 767 60 900 000 78.7 D 0 0 B 0W HALO S CL B 0V 9880 0 900 000 78.6 D 0 0 B 0W HALO S CL B 0V 9886 900 000 78. D 0 0 B 0W HALO S CL B 0V 9879 0 900 000 78.6 D 0 B W HALOS CL B 0V 769 60 900 000 78.7 D Candela (cd) Beam Angle ( ) HaloReflector Halogen 8 0 E 8W HALO R0 E 0V 76* 0 900 000 0 86 8.87 E 8 0 0 E 0W HALO R0 E 0V 7 0 900 000 0 86. D 8 0 0 E 0W HALO R0 E 0V 0 900 000 0 86 0.79 D 0 0 E7 W HALO R6 E7 0V 96 80 0 0 900 000 6. 0. D 6 0 E7 W HALO R6 E7 0V 9 80 0 0 900 000 6. 0. D 0 6 0 E7 W HALO R80 E7 0V 99 8 60 0 900 000 80. D 0 6 70 0 E7 70W HALO R80 E7 0V 606 00 0 900 000 80 7.9 D 0 6 70 0 E7 70W HALO R80/E7 0V 6060 00 0 800 000 80 6 7.9 D 0 6 0 E7 W HALO R80 E7 0V 97 8 0 80 900 000 80. D 6 * Will be phased out Halogen Tubular T8 7 000 0 E0 Halo T8/000W/E0/0 08 000 900 000 8 80 008.89 D 0 7 000 0 E0 Halo T8/000W/E0/0 09 000 900 000 8 80 08. D 0 6 7
Incandescent Incandescent Incandescent Lamps
Incandescent Lamps Specialised Lamps for special applications Our company was born out of Thomas Edison s invention of the world s first commercially viable light bulb More than a century later, our lighting business still brings light to the world, helping to advance new technologies that operate with greater efficiency, less cost and less environmental impact than ever before. We invented Incandescent technology and we know how to replace it. Recent years have seen the gradual phasing out of the use of Incandescent Lamps across most applications as new technologies have superseded them. Across the EMEA region, this has been driven by legislation based on the EU Ecodesign Directive, legislation that covers all energy using products sold in the domestic, commercial and industrial sectors. The recent amendment of these Ecodesign requirements allows exemption for a limited number of Incandescent Lamp types: Pygmy for oven, freezer and sewing machine Infrared reflector Low Voltage GLS Coloured decorative lamps FOR SPECIAL ENVIRONMENTS FOR INFRARED APPLICATIONS COLOURED LAMPS Incandescent! As a member of ELC (European Lamp Companies Federation), we are fully committed to this regulation and to offering a complete range of new, energy efficient products to replace old Incandescent lamps. Incandescent 6 7
Incandescent Lamps overview R9 : E Wattages: 0W Rated life: 000 h R0 : E Wattages: 60W Rated life: 000 h R6 : E7 Wattages: 0 60W Rated life: 000 h Standard : E7, B or E0 Wattages: 00W Finish: Clear or Frosted Rated life: 000 h Low Volt : E7 Wattages: 00W Voltage: V Finish: Clear or Frosted Rated life: 000 h R80 : E7, B Wattages: 0 00W Rated life: 000 h R9 : E7 Wattages: 00 0W Rated life: 000 h Coloured R0, R6, R80 : E7, E Wattages: 0 60W Rated life: 000 h GLS Reflector Standard : E, E7 or B Wattages: 60W Finish: Clear or Frosted Rated life: 000 h Coloured : E, E7 Wattages: W Finish: colours Rated life: 000 h Oven : E or E7 Wattages:, 0W Finish: Clear Rated life: 00 h Infrared Hard Glass : E7 Wattages: 00 7W Finish: Clear, Red or Satin Rated life: 000 h Spherical Infrared Reflector Incandescent Incandescent Standard : E, E7 Wattages: 60W Finish: Opal, Frosted or Clear Rated life: 000 h Twisted : E Wattages: 60W Finish: Clear or Frosted Rated life: 000 h Standard and Appliance : E Wattages: W Finish: Clear Rated life: 000 h Candle Pygmy 8 9
Incandescent Lamps Incandescent Lamps 0 E D/FR/E 9777* 0 000 7 E /0/00 0 0 E 0D/FR/E 9778* 00 000 7 0 E /0/00 60 0 E 60D/FR/E 9786* 660 000 7 60 E /0/0 0 0 E7 0D/F/E7 9067* 00 000 69. 0 E /0/0 60 0 E7 60D/F/E7 9068* 660 000 69. 60 E /0/0 Standard GLS Clear Spherical Frosted Incandescent 0 E7 A/CL/E7 99* 000 0 88. E /0/0 0 0 E7 0A/CL/E7 996* 0 000 0 88. 0 E /0/0 60 0 E7 60A/CL/E7 997* 700 000 0 88. 60 E /0/0 7 0 E7 7A/CL/E7 998* 90 000 0 88. 7 E /0/0 00 0 E7 00A/CL/E7 999* 0 000 0 88. 00 E /0/0 0 0 E7 0A6/CL/E7 66* 60 000 6 0 E /0 00 0 E7 00A/CL/E7 97* 00 000 80 00 E /0 00 0-0 E7 00A/CL/E7 96* 80 000 90 68 00 E /0 00 0-0 E0 00A/CL/E0 97* 80 000 90 80 00 E /0 0 0 B 0A/CL/B 998* 0 000 0 88. 0 E /0/0 60 0 B 60A/CL/B 996* 700 000 0 88. 60 E /0/0 7 0 B 7A/CL/B 996* 90 000 0 88. 7 E /0/0 00 0 B 00A/CL/B 9967* 0 000 0 88. 00 E /0/0 Standard GLS Frosted 0 0 E7 0A/F/E7 99* 0 000 0 88. 0 E /0/0 60 0 E7 60A/F/E7 99* 700 000 0 88. 60 E /0/0 00 0 E7 00A/F/E7 996* 0 000 0 88. 00 E /0/0 60 0 B 60A/F/B 66* 70 000 0 88. 60 E /0/60 Low Volt GLS Clear E7 A/CL/E7 V 78 0 000 60 0.. D /0/00 0 E7 0A/CL/E7 V 9876 80 000 60 0.. D /0/00 60 E7 60A/CL/E7 V 9877 90 000 60 0. 6 D /0/00 00 E7 00A/CL/E7 V 7 70 000 60 0. 07. D /0/00 Low Volt GLS Frosted 60 E7 60A/F/E7 V 987 90 000 60 0. 6. D /0/00 00 E7 00A/F/E7 V 987 70 000 60 0. 06.7 D /0/00 Spherical Clear 0 E D/CL/E 977* 0 000 7 E /0/00 0 0 E 0D/CL/E 978* 00 000 7 0 E /0/00 60 0 E 60D/CL/E 978* 660 000 7 60 E /0/00 0 E7 D/CL/E7 997* 00 000 69. E /0/0 0 E7 D/CL/E7 906* 0 000 69. E /0/0 0 0 E7 0D/CL/E7 906* 00 000 69. 0 E /0/0 0 B D/CL/B 99* 00 000 70 E /0/0 * Not CE compliant product Coloured Spherical Colour 0 E7 D/CL/E7 0 00 7 E /0/00 0 0 E 0D/CL/E 6 0 00 7 0 E /0/0 0 0 E7 0D/CL/E7 0 00 7 0 E /0/00 0 E C/CL/E 9078* 0 000 97 E /0/0 0 0 E7 0C/CL/E7 0879* 00 000 9 0 E /0/00 60 0 E7 60C/CL/E7 0880* 660 000 9 60 E /0/00 0 E D/R/E 90 Red 000 7. N/A /0/0 0 E7 D/R/E7 90 Red 000 69.. N/A /0/0 0 E7 D/ORANGE/E7 908 Orange 000 69.. N/A /0/0 0 E D/Y/E 906 Yellow 000 7. N/A /0/0 0 E7 D/Y/E7 907 Yellow 000 69.. N/A /0/0 0 E D/G/E 900 Green 000 7. N/A /0/0 0 E7 D/G/E7 9 Green 000 69.. N/A /0/0 0 E D/B/E 900 Blue 000 7. N/A /0/0 0 E7 D/B/E7 9 Blue 000 69.. N/A /0/0 Spherical Oven - Clear Candle - Clear Candle - Frosted 6 6 6 7 7 7 Incandescent - explanation For further information check the glossary A / FR / E7 0 E C/FR/E 9680* 0 000 97 E /0/0 0 0 E 0C/FR/E 968* 00 000 97 0 E /0/0 * Not CE compliant product 8 8 Identifies lamp wattage Identifies the lamp type: A=GLS, C=Candle, Rxx=Reflector/ IR = Infrared (xx=diameter), P=Pygmy, D=Spherical Identifies the finish of the lamp: F/FR = Frosted CL = Clear O/SL = Opal R/Y/G/B = Colour options Identifies the cap type 6 7 8 0
Incandescent Lamps Incandescent Lamps Candela (cd) Beam Angle ( ) Candle Opal Reflector - R80 0 E C/SL/E 908* 80 000 97 E /0/0 0 0 E 0C/SL/E 908* 60 000 97 0 E /0/0 60 0 E 60C/SL/E 908* 600 000 97 60 E /0/0 0 E7 C/O/E7 087* 80 000 9 E /0/0 0 0 E7 0C/O/E7 0877* 60 000 9 0 E /0/0 60 0 E7 60C/O/E7 0878* 600 000 9 60 E /0/0 Decor Candle - Twisted Clear 0 0 E 0TC/CL/E 087* 00 000 97 0 E /0/0 60 0 E 60TC/CL/E 088* 660 000 97 60 E /0/0 Decor Candle - Twisted Frosted 0 E TC/F/E 08* 0 000 97 E /0/0 0 0 E 0TC/F/E 08* 00 000 97 0 E /0/0 60 0 E 60TC/F/E 08* 660 000 97 60 E /0/0 0 0 E7 0R80S/E7 988* 00 000 80 09. 0 E /0 60 0 E7 60R80S/E7 989* 0 000 80 09. 60 7 E /0 7 0 E7 7R80S/E7 989* 600 000 80 09. 7 E /0 00 0 E7 00R80S/E7 9860* 800 000 80 09. 00 E /0 Reflector - R9 00 0 E7 00R9/E7 966* 0 000 9 7. 00 E / 0 0 E7 0R9/E7 967* 0 000 9 7. 0 E / * Not CE compliant product Colour 7 7 7 7 8 8 * Not CE compliant product Coloured Reflector - R0 Candela (cd) Beam Angle ( ) 0 0 E 0R0/R/E 986 Red 000 0 86 9. N/A / 0 0 E 0R0/Y/E 988 Yellow 000 0 86 9. N/A / 0 0 E 0R0/G/E 989 Green 000 0 86 9. N/A / 0 0 E 0R0/B/E 987 Blue 000 0 86 9. N/A / 9 9 9 9 Incandescent Reflector - R9 0 E R9/E 9* 6 6 000 9 6..9 E /0/00 0 0 E 0R9/E 9* 80 6 000 9 6. 0. E /0/00 0 E R9/E 9* 6 6 000 9 6..9 E /0/00 0 0 E 0R9/E 9* 80 6 000 9 6. 0. E /0/00 Reflector - R0 0 E R0/E 97* 00 000 0 86 E /0/0 0 0 E 0R0/E 966* 00 000 0 86 0. E /0/0 60 0 E 60R0/E 97* 600 000 0 86 60. E /0/0 Reflector - R6 6 6 0 60 0 0 E7 E7 0R6/E7 60R6/E7 9079* 9080* 0 0 000 000 6, 6, 00 00 0. 60. E E /0/0 /0/0 * Not CE compliant product Coloured Reflector - R6 0 0 E7 0R6/R/E7 9 Red 000 6. 00 9. N/A / 0 0 E7 0R6/Y/E7 9 Yellow 000 6. 00 9. N/A / 0 0 E7 0R6/G/E7 9 Green 000 6. 00 9. N/A / 0 0 E7 0R6/B/E7 90 Blue 000 6. 00 9. N/A / Coloured Reflector - R80 60 0 E7 60R80/R/E7 98 Red 000 80 09. 7. N/A /0 60 0 E7 60R80/Y/E7 97 Yellow 000 80 09. 7. N/A /0 60 0 E7 60R80/G/E7 96 Green 000 80 09. 7. N/A /0 60 0 E7 60R80/B/E7 9 Blue 000 80 09. 7. N/A /0 0 0 0 0 0 0 0 0 Incandescent 6 7 8 9 0
Incandescent Lamps 0 0-0 E7 0R/IR/CL/E7 870 N/A 000 7 N/A N/A /9 0 0-0 E7 0R/IR/CL/E7 87 N/A 000 7 N/A N/A /9 7 0-0 E7 7R/IR/CL/E7 69 N/A 000 7 N/A N/A /9 00 0 E7 00R9/IR/R/E7 96 N/A 6 000 9 9 N/A N/A / 0 0 E7 0R/IR/R/E7 97 N/A 000 7 N/A N/A /0 0 0 E7 0R/IR/R/E7 99 N/A 000 7 N/A N/A /0 0 0 E7 0/IR/F/E7 988 N/A 000 7 N/A N/A /0 0 0 E7 0R/IR/F/E7 990 N/A 000 7 N/A N/A /0 7 0 E7 7R/IR/SA/E7 96 N/A 000 7 N/A N/A /9 Infrared Reflector Hard Glass - Clear Infrared Reflector Hard Glass - Red front Infrared Reflector Hard Glass - Satin Pygmy - Clear 0 E P/CL/E 8 000 8 60.6 E /0/0 0 E P/CL/E 99 90 000 8 60.8 E /0/0 0 E P/CL/E 990 8 000. E /0/0 Pygmy Freezer - Clear 0 E P/CL/E 906 8 000. E /0/0 Pygmy Oven - Clear 0 E P/OVEN/CL/E 7 8 000. 8. E /0 0-0 E P/RS/CL/E 90 8 000. 8. E 00 0 E P/OVEN/CL/E 8 60 000.6 E /0 0-0 E P/OVEN/T/CL 0 60 000.6 E 0 Incandescent Specialty Lamps Specialty
Specialty Lamps Our leading role in the development of all kinds of lighting technologies enables us to offer advanced, high performance solutions for specialised applications as diverse as film studios, rock concerts, airport runways and even fly traps! Following are our main areas of expertise: Entertainment We are a leading supplier to the entertainment industry, with a range of lamp technologies sold under the SHOWBIZ brand including incandescent, halogen, metal halide and low energy compact fluorescent. Our ranges encompass everything from low watt to 000W products with bases to fit most known fixtures, and are used in applications such as: Film and broadcast (including studio and location) Events and concert tours Club and disco Theatre Specialist projection (e.g. photographic studio) Horticulture Artificial photosynthesis lighting plays an important role in improving the yield and quality of greenhouse crops, and for controlling day-night lengths to suit the needs of particular flowering plants. Our Lucalox Photosynthesis Lamp (PSL) range offers a number of important advantages: Properly balanced blue and red to optimise growth Improves the yield and quality of greenhouse crops Optimum light and PAR (Photosynthetically Active Radiation) output More PAR on average compared to standard HPS Wide range 0 70W with 0 and 00 V options Special applications We have a choice of lamp technologies fluorescent/halogen, low/high watt, cap options to meet the needs of a diverse range of special applications including: Health & safety (bacterial destruction, shatter protection) Insect control (e.g. fly traps in food preparation areas) Industrial heating (radiant heat for applications such as paint drying) Airfields (lamps for runways and taxiway lighting) Specialty Specialty ENTERTAINMENT HORTICULTURE SPECIAL APPLICATIONS 6 7
Specialty Lamps / Entertainment Lamps overview PAR Range: PAR6, 6, 6, 6 Wattage: Up to 00W Candelas: Up to 76 000 Rated life: Up to 000 h Club and Disco Single Ended Hot Restrike Wattages: 8 000W Lumens: 9 800 60 000 CCT: 6000K Rated life: Up to 70 h Double Ended Hot Restrike Wattage: Up to 000W Lumens: 000 00 000 CCT: 600 6000K Rated life: Up to 70 h Cinema Studio Biax Wattage: W Lumens: 00 00 CCT: 00 & 600K Rated life: Up to 8 000 h Single Ended Halogen Wattage: 0 000W Volts: 0 0V Lumens: 000 800 000 CCT: 00 00K Rated life: Up to 00 h Single ended halogen HPL : G9./Heat Sink Wattages: 7 70W Rated life: 00 000 h Single ended halogen : G9. Wattages: 7 6 70W Rated life: 00 000 h Double ended halogen : R7s Wattages: 00 000W Rated life: 7 00 h Film and Broadcast Theatre Specialty Single Ended Cold Start Wattage: Up to 00W Lumens: Up to 0 000 CCT: 600 9000K Rated life: 800 000 h Double Ended Hot Restrike Wattage: 7 00W Lumens: Up to 0 000 CCT: 800 700K Rated life: 00 70 h Short Arc Wattage: 00W Lumens: 00 000 CCT: 800K Rated life: 70 h CSS/CSI/CID : G8 Wattages: 00 000W Rated life: 00 00 h Specialty Event and Tour Other applications 8 9
Specialty Lamps / Entertainment Lamps Film and broadcast Specialty Lamps / Entertainment Lamps Film and broadcast, event and tour Volts description LIF ANSI Operating position Outer qty 0+60 0-0 GX8q CP0 0/60W 0-0V 88880 7 000+ 000 00 CP0 0 0 BD D 99.00 0+0 0-0 GX8q CP0 0-0V 88877 7 000+7 000 00 CP0 00 0 BD D 8.00 Volts description Volts description Operating position LIF ANSI Operating position Outer qty Single Ended Halogen (Lower wattages are shown in the Theatre section) Single Ended Halogen (Lower wattages are shown in the Theatre section) Discharge Single Ended Hot Restrike 80 GZX9. CSR/SE/HR 86 9 800 6000 00 7 U A 7.0 0 00 70 GZY9. CSR00/SE/HR/UV-C 906 6 000 6000 00 80 U A 0.00 0 00 67 GZZ9. CSR 00SE/HR/UV-C 906 000 6000 60 0 U A 0.00 0 7 9 G CSR 7/SE/HR/UV-C 6906 8 000 6000 70 U A 6.0 0 800 9 G CSR800/SE/HR/UVC 906 6 000 6000 000 U A 880.00 6 00 00 G8 CSR 00 SE/HR/UV- C 776 0 000 6000 70 00 U A+ 0.00 6 600 0 G CSR 600/SE/HR/UV-C 906 0 000 6000 00 7 U A+ 760.00 6 800 0 G8 CSR 800/SE/HR 7790 6 000 6000 70 00 U A+ 980.00 6 00 G8 CSR 00/SE/HR/UV-C 08 0 000 6000 00 0 U A 70.00 6 000 00 G8 CSR 000SE/HR/UV- C 776 80 000 6000 00 60 U A+ 00.00 6 6 6000 0 G8 CSR 6000/SE/HR/UV-C 09 0 000 6000 00 60 U A+ 6600.00 6 6 9000 60 G8 CSR9000/SE/HR 68 87 000 6000 0 60 U A+ 87.00 6 6 000 G8 CSR000/SE/HR/ UV-C 977 0 000 6000 00 0 U A+ 00.00 6 8 000 G CSR8000/SE/HR 96 60 000 6000 0 70 U A+ 9800.00 Discharge Double Ended Hot Restrike Outer quantity 0+60 0-0 GX8q CP0 0/60W 0-0V 88880 7 000+ 000 00 CP0 0 0 BD D 99.00 9 0+0 0-0 GX8q CP0 0-0V 88877 7 000+7 000 00 CP0 00 0 BD D 8.00 9 0+00 0-0 GX8q CP8 0-0V 88878 7 000+9 000 00 CP8 00 0 BD C 79.00 0 00+00 0-0 GX8q CP 0-0V 88879 9 000+9 000 00 CP 00 0 BD C 09.00 000 0 G8 CP9 0V 8887 00 00 CP9 7 79 BDTH C 00.00 000 0 G8 CP9 0V 88876 000 00 CP9 7 79 BDTH C 00.00 000 0 G8 HX000/0V 779 000 00 00 70 6 U C 6.7 6 0 000 0-0 G8 CP8 0-0V 06 80 000 00 CP8 00 0 BDTH C 996.00 0 000 0 G8 CP8 0V 07 80 000 00 CP8 00 0 BDTH C 9777. 000 0 GX8 QMT6/CL 0V 877 00 000 00 0 0 BD B 600.7 000 0 GX8 QMT6/CL 0V 8779 00 000 00 0 0 BD C 69.7 0 000 0 GX8 Q0MT/CL 0V 877* 80 000 00 BCM 00 60 BD C 876. 6 0 000 0 GX8 Q0MT/CL 0V 877 80 000 00 BCM 00 60 BD C 977.9 6 000 0 GX8 QMT/CL 0V 8777 800 000 00 0 60 BD B 778.0 7 Cinema Studio Biax G- PIN FBX/STUDIOBIAX 869 00 00 8 000 U A 60.0 0 8 G- PIN FBX/STUDIOBIAX6 87 00 600 8 000 U A 60.0 0 8 G- PIN FBX/CINPLUS/ 90 00 00 000 U B 60.0 0 8 G- PIN FBX/CINPLUS/ 9 00 600 000 U B 60.0 0 8 * While stock lasts Volts description Operating position Outer quantity 7 00 00 SFc 0--6 Sl/M6 CSR00/DE 8* 0 000 6000 70 0 HOR± A+ 0.00 0 7 00 Sta- CSR00/DE 8* 0000 6000 00 HOR± A+ 70.00 6 7 6000 X Cyl 6mm CSR6000/DE 86* 70 000 6000 00 0 HOR± A+ 6600.00 0 7 000 60 0x70 Cyl 6mm CSR000/DE 87* 00 000 6000 00 70 HOR± A+ 00.00 0 7 8 000 0x70 Cyl 6mm CSR8000/DE 89 60 000 6000 00 00 HOR± A+ 9800.00 8 000 70 0x70 Cyl 6mm CSR 000/DE 7870* 00 000 6000 00 00 HOR± A 600.00 * While stock lasts Discharge Single Ended Cold Start 0 9 GY9. CSD 0/ SE 07 8 000 800 000 08 U A 7.00 0 9 7 97 GX9. CSR7//T/SE 99* 000 7600 000 U A 6.0 0 0 7 97 GX9. CSR7//SE 6906 6 000 700 000 U A 6.0 0 700 70 G CSR700//SE 99 000 600 000 U A 770.00 0 00 00 G CSR00//SE 990 0 000 7000 800 7 U A+ 0.00 6 Discharge CSR Turn and Lock (TAL) 700 70 PGJX8 CSR700/TAL 7878* 0 000 700 70 U A 770.00 explanation For further information check the glossary * While stock lasts Specialty CSR 000 / SE / HR / UV-C Specialty (CSR) High Intensity Discharge lamp brand name code Hot Restrike Identifies the lamp as single ended finish of the lamp The lamp has UV control Identifies lamp wattage 6 7 8 9 0 6 7 8 9 0 0
Specialty Lamps / Entertainment Lamps Event and tour, club and disco Specialty Lamps / Entertainment Lamps Club and disco Volts description Operating position Outer quantity Volts description LIF ANSI Candelas Beam type Beam 0% Beam 0% Operating position Outer qty Discharge Double Ended Hot Restrike PAR 6 7 9 SFc 0- SI/M CSR7/S/DE/70 70979* 0 000 7000 70 8 U A 6.0 0 0.8 H76.8V 9 Screw Terminals 00 60 000 VNSP 6. x 9. 6 U Exempt Exempt 60 8 78 8.0V 00* Contact Lugs 800 600 9. 6 U Exempt Exempt 80 8 79 8V 80W 009 Contact Lugs 00 000 9. 6 U Exempt Exempt 00 7-.0V 08 Screw Terminals 00 000 SP x 6 9. 6 U Exempt Exempt 0 8 8.0V 79 Screw Terminals 7 000 9. 6 U Exempt Exempt 0 8 8.0V 799 Screw Terminals 00 000 SP x 9. 6 U Exempt Exempt 0 6. 6 8* Screw Terminals 000 9. 6 U Exempt Exempt 0 8 80 8.0V 89 Screw Terminals 0 00 000 SP x 9. 6 U Exempt Exempt 0 8 Q 8.0V 7706 Screw Terminals 00 6 000 WFL 0 x 9. 6 U Exempt Exempt 0 8 Q68 8.0V 67 Screw Terminals 0 0 000 SP x 9 9. 6 U Exempt Exempt * While stock lasts 7 00 SFc 0- Sl/M CSR7/SS/DE/7 * 000 700 00 9 HOR± A 6.0 0 700 70 SFc 0- Sl/M CSR700/S/DE/60 9* 9 000 6000 70 8 U A 770.00 0 700 70 SFc 0- Sl/M CSR700/S/DE/7 7* 000 700 70 8 U A 770.00 0 00 00 SFc 0- Sl/M CSR00/S/DE/60 9* 0 000 6000 70 8 U A+ 0.00 0 00 SFc 0- Sl/M CSR00/S/DE/60 96800* 0 000 800 00 8 HOR± A 60.00 0 Discharge Short Arc 00 00 GY CSR 00/SA 89* 00 000 800 70 U A 0.00 6 * While stock lasts Volts description LIF ANSI Rated Life (h) Candelas Beam type Beam 0% Beam 0% Operating position Outer qty PAR 6 00 00W V 768 Screw Terminals 00 000 NSP 9 x 7 77.8 U Exempt Exempt 0 0PAR6WFL V 90 Screw Terminals 000 6 WFL x 8 0 x 7 77.8 U D.9 00 0 00PAR 0V 0 Screw Terminals 0 70 000 SP 9 x 9 7 77.8 U Exempt Exempt 0 0PAR6/VNSP V 07 Screw Terminals 000 0 000 VNSP 9 x 6 7 x 0 7 77.8 U E 60.08 0 0PAR6/WFL V 077* Screw Terminals 000 000 WFL x 8 0 x 7 7 77.8 U E 60.08 00 00PAR6/WFL V 7 Screw Terminals 000 WFL 7 77.8 U C 09. 00 0 00PAR6/NSP 0V 080 70 Mog End Pr GX6d 000 68 000 NSP 0 x 8 0 x 7 77.8 U E.6 00 0 00PAR6/MFL 0V 086 70 Mog End Pr GX6d 000 000 MFL x x 9 7 77.8 U E 8.70 00 0 00PAR6/WFL 0V 089 70 Mog End Pr GX6d 000 000 WFL 7 x 8 7 x 7 7 77.8 U E 8.70 00 0 00PAR6/MFL 0V 08 ExMogEndPr GX6d 000 0 000 MFL 7 77.8 U E 9.9 00 0 00PAR6/NSP 0V 08 ExMogEndPr GX6d 000 0 000 NSP 7 77.8 U E 9.9 00 0 00PAR6/WFL 0V 08 ExMogEndPr GX6d 000 0 000 WFL 7 77.8 U E 9.9 00 0 00PAR6/NSP 0V 8676 ExMogEndPr GX6d 000 0 000 NSP 7 77.8 U E 8.8 00 0 00PAR6/MFL 0V 8677 ExMogEndPr GX6d 000 0 000 MFL 7 77.8 U E 8.8 00 0 00PAR6/WFL 0V 8678 ExMogEndPr GX6d 000 0 000 WFL 7 77.8 U E 8.8 00 0 Q00PAR6MFL 0V 9 90 Mog End Pr GX6d 000 000 MFL 6 x 0 x 0 7 77.8 U D 0. 6 6 00 0 Q00PAR6WFL 0V 96 90 Mog End Pr GX6d 000 9 000 WFL x 0 66 x 7 77.8 U D 0. 6 6 00 0 Q00PAR6NSP 0V 9 90 Mog End Pr GX6d 000 96 000 NSP x 8 x 7 77.8 U D 0. 6 6 * While stock lasts PAR 6. PAR6.V 000 Screw Term. 000 0 000 VNSP x 69.8. U E 6. PAR6/WFL V Screw Term. 000 00 WFL 9 x 7 x 6 69.8. U E 6.0 6 0.8 0.8V Screw Term. 00 0 000 VNSP 6 x 69.8. U Exempt Exempt 6 0 6. 6.V 66 Screw Term. 00 00 69.8. U Exempt Exempt 0 6. H 6.V Screw Term. 00 67 000 VNSP. x 69.8. U E. 7 0 6. 6.V 67 Screw Term. 00 000 VNSP x 69.8. U E.8 0.8 H760.8V 76 Screw Term. 00 00 000 NSP 7 x 69.8. U Exempt Exempt 0 0PAR6/VNSP V 89 Screw Term. 000 000 VNSP 6 x 6 69.8. U E. 0 0PAR6/NSP V 60 Screw Term. 000 9 00 NSP 0 x 0 69.8. U E.98 6 0 0PAR6/WFL V 6 Screw Term. 000 00 WFL 8 x 6 x 8 69.8. U E.98 6 0 0PAR6/WFL/H V 9880 00 Screw Term. 000 00 WFL 0 x 0 69.8. U E. 6 0 8 0 8.0V 67 Screw Term. 00 0 000 WFL 0 x 7 69.8. U Exempt Exempt 6 0 8 0 8.0V 60 Screw Term. 00 000 NSP x 69.8. U Exempt Exempt 6 0 8 89 8V 0W 87 Screw Term. 00 000 69.8. U Exempt Exempt 7 00 09.0V 60 Screw Term. 0 00 NSP x 6 69.8. U Exempt Exempt 00 09X.0V 0 Screw Term. 0 000 NSP x 6 69.8. U Exempt Exempt 8 0 8 9 8.0V 887 Screw Term. 00 00 VWFL 80 x 0 69.8. U Exempt Exempt 6 00 8 9 8.0V 89 Screw Term. 00 70 000 NSP x 7 69.8. U Exempt Exempt 6 0 8 66 8.0V 96 Screw Term. 00 000 WFL 0 x 9 69.8. U Exempt Exempt 6 00 8 67 8.0V 966 Screw Term. 00 000 VWFL 80 x 0 69.8. U Exempt Exempt 9 0 8 87 8.0V 867 Screw Term. 000 WFL 0 x 69.8. U Exempt Exempt 9 0 8 96 8.0V 898 000 Screw Term. 0 000 NSP x 69.8. U Exempt Exempt 6 60 0 DWE Q60PAR6/ 0V 667 00 DWE Screw Term. 00 000 MFL 0 X 0 69.8. HOR± D 69.0 0 60 0 FBO-Q60/PAR6/ 0V 67 00 FBO Screw Term. 0 7 000 SP X 69.8. HOR± D 69.0 6 60 0 FCX-Q60PAR6/7 0V 67 00 FCX Ferrule 00 000 MFL 0 X 0 69.8. HOR± D 69.0 Specialty Specialty 6 7 8 9 0 6
Specialty Lamps / Entertainment Lamps Club and disco Specialty Lamps / Entertainment Lamps Theatre Specialty Specialty Volts description LIF ANSI Candelas Beam type Beam 0% Beam 0% Operating position Outer qty Volts description Lumens LIF ANSI Operating position Outer qty PAR 6 0 8 8.0V 076 Screw Terminals 00 000 SP 7 X 8. 0. U Exempt Exempt 600 8 9 8.0V 078 Screw Terminals 600 000 SP X. 0. U Exempt Exempt 600 8 Q9 8.0V 079 Screw Terminals 00 600 000 SP X 8. 0. U Exempt Exempt 600 8 Q9X 8.0V Screw Terminals 00 76 000 SP x7.. 0. U Exempt Exempt 00 0 CP86 Q00PAR6/VNSP 0V 78 00 CP86 GX6d 00 0 000 VNSP 6x 0x7. 0. U D 96.6 6 00 0 CP86 Q00PAR6/VNSP 0V 999 00 CP86 GX6d 00 0 000 VNSP 6x 0x7. 0. U C 07.66 6 00 0 CP87 Q00PAR6/NSP 0V 999 00 CP87 GX6d 00 0 000 NSP 9x6 x9. 0. U D 99.88 6 00 0 CP87 Q00PAR6/NSP 0V 9996 00 CP87 GX6d 00 0 000 NSP 9x6 x9. 0. U C.6 6 00 0 CP88 Q00PAR6/MFL 0V 9997 00 CP88 GX6d 00 6 000 MFL x9 x0. 0. U D 98.86 6 00 0 CP88-Q00PAR6/MFL 0V 9998 00 CP88 GX6d 00 6 000 MFL x9 x0. 0. U C 98.86 6 00 0 00PAR6/MFL 0V 9 700 ExMogEndPr GX6d 000 MFL X 0 x 9. 0. U E 0.90 00 0 00PAR6/WFL 0V 9 700 ExMogEndPr GX6d 000 WFL X 0 x. 0. U E 0.90 00/000 8 7 8/8V 08 0 Screw Terminals 0 000 0 U Exempt Exempt 000 0 SUPER CP60 EXC VNS 0V 88 00 CP60 GX6d 00 000 VNSP 0x7 x9. 0. U C 0.70 6 000 0 SUPER CP60 EXC VNS 0V 88 00 CP60 GX6d 00 000 VNSP 0x7 x9. 0. U C 06.0 6 000 0 SUPER CP6 EXD NS 0V 88 00 CP6 GX6d 00 97 000 NSP x0 x0. 0. U C 00.70 6 000 0 SUPER CP6 EXD NS 0V 880 00 CP6 GX6d 00 97 000 NSP x0 x0. 0. U C 09.9 6 000 0 SUPER CP6 EXE MF 0V 889 00 CP6 GX6d 00 8 000 MFL 8x0 x. 0. U C 06.9 6 000 0 SUPER CP6 EXE MF 0V 886 00 CP6 GX6d 00 8 000 MFL 8x0 x. 0. U C 07. 6 000 0 CP9 0V 88* 00 CP9 ExMogEndPr GX6d 00 000 VWFL x 9 70 X 70. 0. U C 99.0 6 000 0 CP9 0V 880 00 CP9 ExMogEndPr GX6d 00 000 VWFL x 9 70 X 70. 0. U C 999.8 6 000 0 EXG PAR6/000W/0V/WFL 8880 00 EXG ExMogEndPr GX6d 00 9 00 WFL 9 x 6 X. 0. U C 99.78 6 000 0 EXG PAR6/000W/0V/WFL 8879 00 EXG ExMogEndPr GX6d 00 9 00 WFL 9 x 6 X. 0. U C 006. 6 00 0 00PAR6/MFL 0V 909* 800 ExMogEndPr GX6d 000 7 000 MFL X x 9. 0. U E 9.97 000 0 FFN 0V 00 FFN ExMogEndPr GX6d 800 0 0000 VNSP X 6 x 0. 0. U E 08.8 6 000 0 FFP 0V 9 00 FFP ExMogEndPr GX6d 800 0 000 NSP X 7 6 x. 0. U E 08.8 6 000 0 FFR 0V 8 00 FFR ExMogEndPr GX6d 800 000 MFL 8 X x. 0. U E 08.8 6 000 0 FFS 0V 7 00 FFS ExMogEndPr GX6d 800 0 000 WFL 8 X 7 x. 0. U E 08.8 6 000 0 Q000PAR6NSP 0V 97 000 ExMogEndPr GX6d 000 00 000 NSP X 8 X. 0. U D 0. 6 000 0 Q000PAR6MFL 0V 98 000 ExMogEndPr GX6d 000 80 000 MFL 8 X x. 0. U D 0. 6 000 0 Q000PAR6WFL 0V 99 000 ExMogEndPr GX6d 000 000 WFL 8 X 7 x. 0. U D 0. 6 00 0 GFC 00W 0V VNSP 8887 00 GFC ExMogEndPr GX6d 00 0 000 VNSP 8x0 x6. 0. U D 88.8 6 * While stock lasts Single Ended Halogen HPL (9 mm diameter) 7 G9./Heat Sink HPL7-C V 880 0 0 00 00 06 U C 8. 7 G9./Heat Sink HPL7-LL-C V 889 8 000 00 000 06 U E 0.07 7 0 G9./Heat Sink HPL 7W 0V 8878 900 00 00 06 U C 99.98 7 0 G9./Heat Sink HPL 7W 0V 8877 900 00 00 06 U D 97.77 7 0 G9./Heat Sink HPL 7-C 0V 886 6 0 0 00 06 U C 9. 7 G9./Heat Sink HPL 7-C V 888 6 0 0 00 06 U C 67.98 7 0 G9./Heat Sink HPL 7W LL 0V 8876 780 00 00 06 U D 9.8 7 0 G9./Heat Sink HPL 7W LL 0V 887 780 00 00 06 U D 9. 7 0 G9./Heat Sink HPL 7-X LL-C 0V 88 60 00 000 06 U D 6.6 7 G9./Heat Sink HPL 7-X LL-C V 88 60 00 000 06 U D 6.6 70 0 G9./Heat Sink HPL 70W 0V 887 9 70 00 00 06 U C 776.97 70 0 G9./Heat Sink HPL 70W 0V 887 9 70 00 00 06 U C 77.78 70 G9./Heat Sink HPL 70-C V 887 000 0 00 06 U C 89.9 70 G9./Heat Sink HPL 70W-XLL-C V 888 6 00 00 000 06 U D 808.07 70 0 G9./Heat Sink HPL 70W LL 0V 880 600 00 00 06 U D 77.0 70 0 G9./Heat Sink HPL 70W LL 0V 889 600 00 00 06 U D 79.9 Single Ended Halogen 7 G9. FLK 7W V G9. 888 6 00 00 FLK 00 0 U C 69.6 6 7 G9. HX60 FLK/LL 7W/-0V 88 0 000 00 EHD 000 0 U D 6.86 0 7 7 G9. GLC 7W HP V 88 00 00 GLC 00 0 U D 608.9 8 7 G9. GLA 7W HP V LL 88 000 00 GLA 00 0 U D 6.67 9 600 0 G9. GKV 600W 0V G9. 888 000 00 GKV 0 0 U C 8.6 7 600 0 G9. GKV 600W 0V G9. 887 000 00 GKV 0 0 U C 8.8 7 600 0 G9. GKV LL 0V 600W 886 000 000 GKV 00 0 U D 9.6 7 600 0 G9. GKV LL 0V 600W 88 000 000 GKV 00 0 U D 87.77 7 60 0-0 G9. FKR 0-0V 880 000 00 FKR 00 0 U C 6.78 7 70 G9. GLE V 886 7 00 00 GLE 00 0 U D 87.0 9 70 0 G9. EHF Q70/CL 8867 0 000 00 EHF 00 0 U C 80.0 0 70 0 G9. EHG Q70/CL/TP 70W 0V 8866 6 00 000 FLK 00 0 U E 80. 6 7 8 9 0
Specialty Lamps / Entertainment Lamps Theatre Specialty Lamps / Entertainment Lamps Theatre Specialty Specialty Volts description Lumens LIF ANSI Operating position Outer qty Volts description Lumens LIF ANSI Operating position Outer qty Single Ended Halogen 800 0-0 G9. GKV 800W 0-0V 88 0 000 00 HX800 0 0 U C 78.6 000 0 G9. FEL Q000/CL 0V 886 7 00 00 CP77 FEL 00 0 U C 0.88 000 0-0 G9. CP77 FEP 0-0V 889 000 00 CP77 FEP 00 0 U C 980.89 00 0 GY9. CP8 FKW 0V 88 6 900 00 CP8 FKW 0 90 BDTH D.9 00 0 GY9. CP8 FSL 0V 88 6 900 00 CP8 FSL 0 90 BDTH C 7.7 00 0 GY9. CP8 FSK 0V 88 6 900 00 CP8 FSK 0 90 BDTH D 90.9 00 0 GY9. CP8 FRG 0V 8867 000 00 CP8 FRG 0 90 BDTH C.6 00 0 GY9. CP8 FRH 0V 8866 00 00 CP8 FRH 0 90 BDTH C 9.00 00 0 GY9. CP8 FRJ 0V 886 00 00 CP8 FRJ 0 90 BDTH C.78 00 0-0 GY9. T8 GCW 0-0V 886 000 00 T8 GCW 00 90 BDTH C 07.8 6 00 0-0 GY9. T 0-0V 000 000 T GCW 60 90 BDTH C 98. 60 0-0 GY9. T7 0-0V 8869 00 00 T7 GCS 00 90 BDTH C 68.8 7 60 0-0 GY9. T6 GCS 0-0V 886 00 00 T6 GCS 00 90 BDTH C 66.8 8 60 0 GY9. CP89 FRK 0V 886 6 900 00 CP89 00 90 BDTH C 7.7 8 60 0-0 GY9. CP89 FRM 0-0V 886 6 0 00 CP89 FRM 0 90 BDTH C 66.69 9 60 0-0 GX9. T 0-0V 88 00 000 T 70 0 BDTH D 668.6 0 60 0 GX9. CP 0V 7680 6 900 00 CP 00 0 BDTH C 6.6 0 60 0-0 GX9. CP 0-0V 88 6 900 00 CP 00 0 BDTH C 67.6 0 000 0-0 GX9. CP 0-0V 889 6 000 00 CP 00 0 BDTH C 0.60 000 /0 GX9. T -0V 88 00 00 T 70 0 BDTH D 06. 000 0-0 GX9. T 0-0V 886 000 00 T 70 0 BDTH C 00. 000 0-0 GX9. T9 FWR 0-0V 887 000 00 T9 FWR 70 0 BDTH D 99. 000 0 GX9. CP70 FVA 0V 887 000 00 CP70 FVA 00 0 BDTH C 996.0 000 0 GX9. CP70 FVA 0V 887 000 00 CP70 FVB 00 0 BDTH C 996.80 00 0-0 GX9. T9 FWT 0-0V 88 9 000 00 T9 FWT 00 0 BDTH C 9.8 00 0-0 GX9. CP90 0-0V 88 000 00 CP90 00 0 BDTH C 87. 000 0 GY6 CP FTM 0V 967 000 00 CP FTM 00 BDTH C 0.80 000 0-0 GY6 CP FTL 0-0V 88 000 00 CP FTL 00 BDTH C 0.69 000 0-0 GY6 CP79 0-0V 880 000 00 CP79 0 BDTH C 0.0 000 0 GY6 CP79 0V 880 CP79 BDTH C 86.99 00 80 G CP0 OC-00 80V 889 7 00 00 00 0 BDTH C 0.8 6 00 0 G EGN 0V 8809 000 00 EGN 0 0 BDTH C. 60 0-0 G CP9 FKH 0-0V 88 6 900 00 CP9 FKH 00 0 BDTH C 6.6 70 0 G EGR-Q70T7/CL 0 886 000 00 EGR 00 7 BDTH C 80.9 6 000 0 G EGT-Q000T7/CL 0V 886 8 00 00 EGT 0 7 BDTH C 0. Single Ended Halogen 000 0 G CP0 FKJ 0V 888 6 000 00 CP0 FKJ 00 0 BDTH C 00. 7 000 0 G CP0 FKJ 0V 888 6 000 00 CP0 FKJ 00 0 BDTH C 008.77 7 00 0-0 G CP9 0-0V 8808 000 00 CP9 00 0 BDTH C.78 7 000 0 G CP9 0V 8807 000 00 CP9 00 7 BDTH C.8 8 000 0-0 G CP9 0-0V 8806 000 00 CP9 00 7 BDTH C 08.00 8 00 0-0 G CP9 0-0V 880 67 00 00 CP9 00 7 BDTH D 88. 9 00 0 P8s EGE-Q00/CL/P 0V 8867 0 0 90 EGE 000 U D 6.7 0 00 0 P8s BTM 0V 886 000 00 BTM 0 0 BDTH C.6 00 0 P8s BTL-Q00T6/CL/P 0V 887 000 000 BTL 00 BDTH D.9 00 0-0 P8s T7 FKF 0-0V 8898 9 00 90 T7 70 0 BDTH D 0.08 00 0-0 P8s T8 0-0V 88 000 000 T8 00 0 BDTH C 0.97 60 0-0 P8s T FKB 0-0V 8897 00 000 T 70 0 BDTH D 66.6 70 0 P8s EGG-Q70/CL/P0 8869 70 000 EGG 000 BDTH E 80. 70 0 P8s BTN-Q70T7/CL/P 0 8860 7 600 00 BTN 00 BDTH C 8.6 0 000 0-0 P8s T FKD 0-0V 889 000 00 T 70 0 BDTH C 00.06 000 0-0 P8s FKE 0-0V 8899* 000 00 T FKE 70 60 BDTH C 999.0 000 0-0 P8s CP FKN 0-0V 8896 6 000 00 CP FKN 00 BDTH C 00.60 000 0 P8s BTR-Q000T7/CL/P0 88607 8 00 00 BTR 0 BDTH C 0.66 0 000 0 P8s EGK-Q000//P 000W/0V 886 6 00 00 EGK 00 BDTH C 067. 0 000 0 G8 CYV-Q000T7/CL/BP 000W/0V 8860 8 00 00 CYV 00 7 BDTH C 09. 6 0 00 0 G8 CXZ-Q00T0/CL 00W/0V 886 00 00 CXZ 00 6 BDTH C 60.99 6 0 000 0 G8 CYX-Q000T0/CL 0V 8860 9 000 00 HX70 CYX 00 6 BDTH C 7.7 6 6 000 0 G8 CP FKK 0V 8889 000 00 CP FKK 00 6 BDTH C 00.00 7 000 0 G8 CP FKK 0V 8888 000 00 CP FKK 00 6 BDTH C 066.90 7 00 0-0 G8 CP9 0-0V 880 67 00 00 CP9 00 0 BDTH C 07.9 7 000 0-0 G8 HX8 0-0V 8887 8 000 00 HX8 00 0 BDTH C 9.00 8 000 0 E0 DKZ/DSE Q000 996 8 000 00 DSE 70 0 U C 99. 0 0 000 0 E0 BWF-Q000/CL 0V 886 000 00 BWF 00 9 BDTH C. 6 0 000 0-0 E0 CP9 0-0V 88 6 00 00 00 9 U C 99.0 9 000 0 P0s BVV-QMT7/CL/MP 886 8 00 00 BVV 00 8 BDTH C 0.6 6 0 000 0 P0s BVT-QMT7/CL/MP 0V 88608 00 00 BVT 00 8 BDTH C 0. 6 0 000 0 P0s BVW-QMT0/CL/MP 88609 9 000 00 BVW 0 BDTH C. 6 0 000 0-0 P0s CP 0-0V 88 000 00 CP 00 00 BDTH C 066.0 * While stock lasts 6 7 8 9 0 6 7 8 9 0 6 7 8 9 0 6 7
Specialty Lamps / Entertainment Lamps Theatre and other applications Specialty Lamps / Entertainment Lamps Other applications Volts description Lumens LIF ANSI Operating position Outer qty Volts description Lumens LIF ANSI Application Operating position Outer qty Double Ended Quartzline 00 0 R7s TU FDN Q00T/ 7 800 00 P/ FDN 00 9 BDTH C.90 00 0 R7s TU FDF Q00T/CL 7 0 00 P/0 FDF 00 9 BDTH C.6 6 0 R7s TU P/0 Q6T/CL 0/0V 9697 6 900 00 P/0 00 89 HOR± C 6. 6 0 R7s TU P/0 Q6T/CL 0/0V 9698 6 900 00 P/0 00 89 HOR± C 6.9 60 0 R7s FAD Q60T/CL P/6 0 6 00 00 P/6 FAD 00 80 U C 67.7 70 0 R7s TU EMD Q70T/ 7 9 00 00 EMD 00 9 U C 8.9 70 0 R7s TU EJG Q70T/CL 76 0 600 00 EJG 00 9 HOR± C 8.07 800 0 R7s DXX 800-T-CL 0V 69 00 00 P/ DXX 7 80 U C 788.0 800 0 R7s TU P/ EME Q800T/CL 0V 760 000 00 P/ EME 0 9 HOR± C 86.06 800 0 R7s TU P/ EMF Q800T/ 76 00 00 P/ EMF 0 9 HOR± C 8.8 000 0 R7s DXW 07 8 000 00 DXW 0 9 U C 0. 000 0 R7s TU FHM Q000T/ 79 7 00 00 P/9 FHM 00 9 U C 08.8 6 000 0 R7s TU FFT Q000T/CL 80 6 00 00 FFT 00 67 U D 087.6 6 000 0 R7s TU P/7 EKM QMT/CL 0/0V 09 8 000 00 P/7 EKM 00 89 HOR± C 0.60 6 000 0 R7s TU P/7 EKM QMT/CL 0/0V 0 8 000 00 P/7 EKM 00 89 HOR± C 007.0 6 000 0 R7s TU FCM P/8 Q000T/CL 797 8 000 00 P/8 FCM 00 9 HOR± C 08.09 0 0 R7s TU P/ Q0T/CL 0/0V 969* 000 00 P/ 00 89 HOR± C 86.0 0 0 R7s TU P/ Q0T/CL 0/0V 9696 000 00 P/ 00 89 HOR± C 8.60 7 000 0 R7s P/7 FEX 0V 888 0 000 00 P/7 FEX 00 HOR± C 96. 7 000 0 R7s P/7 FEX 0V 888 0 000 00 P/7 FEX 00 HOR± C 97.9 7 000 0 R7s FEY Q000 T8/CL 8869 7 000 00 P/7 FEY 00 HOR± C 7.97 * While stock lasts CSS Volts description Lumens Candelas Beam type Beam 0% Beam 0% MPBC Operating position Outer qty 8 0 8 GY9. CSS0/CAP/0 888 9,000 000 000 8 0 8 VBD±90 A.00 0 CSI/CID Specialist Projector 00 GY6. FCR A/ V 876 00 00 A/ FCR 0 BDTH B.8 00 0 G6. FCS A/6 V Q0/G6.- 98 00 00 A/6 FCS 0 BDTH B 66.07 00 0 G6. EHJ A/ V Q0/G - 87 9 000 00 A/ EHJ 0 7 BDTH B 7. 00 0 0-0 G6. A/8 0-0V 889 000 A/8 0 6 BDTH D. 0 6 00 0-0 G6. A/9 0-0V 889 7 00 A/9 0 6 BDTH C 00. 0 6 00 0-0 GY9. A/ 0-0V 8860 000 A/ 7 6 BDTH C 07. 7 Volts description Single Ended Tungsten Halogen Lumens LIF ANSI Application Operating position Outer qty 0 G6. M6 V 0W GY6. 886 70 000 M6 000 8 BDTH C 70.07 00 8 00 0-0 GY9. M8 0-0V 88 000 900 M8 000 80 BDTH E 97. 0 00 0 GY9. M8 0V 78* 00 900 M8 000 80* BDTH E. 9 00 0-0 GY9. M0 0-0V 8868 8 00 900 M0 000 8 BDTH E 9. * While stock lasts Multi-Mirror Quartzline Projection MR6 0 GX. ENL 7 00 ENL 000 Fibre optics, Enlarger & Printer, BDTH B.0 0 Equipment, Colour printer 8.8 GX. DED.8V 90 0 DED 000 Microfilm BDTH C 90.0 0 0 0 GX. DDL 0V 0W MR6 7 0 DDL 00 Microfilm BDTH B 7.87 0 0 GX. EKE V 00 0 EKE 00 8mm projection BDTH B 9.68 0 0 GX. ELC A/9 V 76 00 ELC 0 6mm, Colour printer BDTH B 6.7 0 6 0 GY. ELC / 00 V 0W 77 0 ELC00 00 Disco BDTH B 60.77 0 60 8 GY. ENX 70 00 ENX 7 Overhead projection BDTH B 89.8 0 0.8 GX. EPT 0.8V 79 900 EPT 8 000 Fibre optics BDTH B.07 0 7 Specialty 9 00 00 Special CSI00 99-00 889 000 000±00 00 VBD±90 A 0.00 9 00 00 Special CSI00/G 99-00 88 000 000±00 00 87 VBD±90 C 0.00 0 000 80 G CSI000/G 99-0 889 90 000 000±00 00 VBD±90 A+ 00.00 000 80 G8 CSI000/PAR6/G8 88 76 000 800±00 00 8 6,0 000 7 U C 00.00 000 80 G8 CSI000/PAR6/HR/G8 99-88 76 000 800±00 00 8 6,0 000 7 U C 00.00 000 80 G CID000/G 99-0 889 70 000 00±00 00 BDTH A 00.00 00 0 GX6d CP88 Q00PAR6/MFL 0V 9997 9 00 00 00 6 000 MFL x9 x0.. U D 98.86 6 00 0 GX6d CP88-Q00PAR6/MFL 0V 9998 0 600 00 00 6 000 MFL x9 x0.. U C 98.86 6 00 0 ExMogEndPr GX6d 00PAR6/MFL 0V 9 00 700 000 MFL X 0 x 9.. U E 0.90 Specialty 6 7 8 9 0 6 7 8 9 0 6 7 8 9
Specialty Lamps / Entertainment Lamps Brand cross reference GE Lighting Osram Philips Discharge Single Ended Hot Restrike CSR/SE/HR HMIW MSR/HR CSR00/SE/HR/UV-C HMI00W/SE MSR00/HR CSR 00SE/HR/UV-C HMI00W/SE MSR00/HR CSR 7/SE/HR/UV-C HMI7W/SE MSR7/HR CSR800/SE/HR/UVC HMI800W/SEL CSR 00 SE/HR/UV- C HMI00W/SE MSR00/HR CSR 600/SE/HR/UV-C CSR 800/SE/HR HMI800W/SE/XS CSR 00/SE/HR/UV-C HMI00W/SE MSR00/HR CSR 000SE/HR/UV- C HMI000W/SE MSR000/HR CSR 6000/SE/HR/UV-C HMI6000W/SE MSR6000/HR CSR9000/SE/HR HMI 9000W/ SE CSR000/SE/HR/ UV-C HMI000W/SE MSR000/HR CSR8000/SE/HR HMI8000W/SE MSR8000/HR Discharge Single Ended Hot Restrike CSR00/DE HMI00W/GS MSI00 CSR00/DE HMI00W/GS MSI00 CSR6000/DE HMI6000W MSI6000 CSR000/DE HMI000W/GS MSI000 CSR8000/DE HMI8000W CSR 000/DE HMI 000W/DXS Discharge Single Ended Cold Start CSD 0/ SE HSD0/80 MSD0/ CSR7//T/SE CSR7//SE HSR7/ MSR7/ CSR700//SE HSR700/ MSR700/ CSR00//SE HSR00/ MSR00/ Discharge CSR Turn and Lock (TAL) CSR700/TAL/PGJX8 HTI 700W/7/P8 MSR 700/ MiniFastFit Discharge Double Ended Hot Restrike Specialty CSR7/S/DE/70 CSR7/SS/DE/7 CSR700/S/DE/60 HTI700W/D/60 CSR700/S/DE/7 HTI700W/D/7 MSR700/SA//DE CSR00/S/DE/60 HTI00W/D7/60 MSR00/SA/DE CSR00/S/DE/60 HTI00 D7/60 Discharge Double Ended Hot Restrike Specialty CSR 00/SA HTI00W/SE MSR00/SA 60 6
Specialty Lamps / Horticulture Lamps overview Specialty Lamps / Horticulture Lamps 0V 0W Lamp volts: V Current:.7A Wattage: 0W 00 h lumens: 000 00 h PAR: 0 μmole/sec Packing: 0V 00W Lamp volts: 0V Current:.A Wattage: 0W 00 h lumens: 6 00 00 h PAR: 70 μmole/sec Packing: or 6 0V 600W Lamp volts: V Current: 6.0A Wattage: 6W 00 h lumens: 90 000 00 h PAR: 080 μmole/sec Packing: or 6 Volts Current (A) 0V E0 ( pack) (6 pack) Max Length Arc gap LCL C 00 hour lumens (Lumens).7 0 LU0W/PSL/T 8866 N/A 60 6 8 8 E0/ 000 0 Hard Universal 0. 0 LU00W/PSL/T 706 0 9 87 7 8 E0/ 6 00 70 Hard Universal 6.0 6 LU600W/PSL/T 707 0 9 69 8 E0/ 90 000 080 Hard Universal 7. 7 LU70W/PSL/T 708 06 9 0 78 E0/ 000 0 Hard Universal 00 hour PAR (μmole/sec) Bulb glass Operating position 00V E0 0V 70W Lamp volts: V Current: 7.A Wattage: 7W 00 h lumens: 000 00 h PAR: 0 μmole/sec Packing: or 6 00.6 60 LU00V/600W/PSL/T 0 9 9. 69 8 E0/ 8 000 0 Hard Universal 00.6 60 LU00V/600/PSL/T/EL 699 69 9. 69 8 E0/ 8 000 0 Hard Universal 0. 76 LU00V/70W/PSL/T 8 7 9 7 E0/ 0 000 90 Hard Universal explanation For further information check the glossary Single Ended 0V LU 00V / 70 / PSL / T / EL Lucalox Lamp wattage Single Ended Electronic version Specialty 00V 600W Lamp volts: 00V Current:.6A Wattage: 60W 00 h lumens: 8 000 00 h PAR: 0 μmole/sec Packing: or 6 00V 600W EL Lamp volts: 00V Current:.6A Wattage: 60W 00 h lumens: 8 000 00 h PAR: 0 μmole/sec Packing: or 6 (Electronic ballast) 00V 70W Lamp volts: 0V Current:.A Wattage: 76W 00 h lumens: 0 000 00 h PAR: 90 μmole/sec Packing: or 6 Lamp voltage PhotoSynthesis Lamp Specialty Single Ended 00V 6 6
Specialty Lamps / Special Solutions Lamps overview Specialty lamps Entertainment Lamps UVC Germicidal T/T8 Lamp volts: 9 V Wattage: 6W : T: G, Fa8 T8: G Rated life: 7 000 9 000 h Packing: Black Light T8 Lamp volts: V Wattage: W : G Rated life: 7 00 h Packing: covrguard Polylux XLR Wattages: 8 8W Colours: White and Cool White : 80+ Rated life: 000 h Packing: Health and Safety UVA Blacklight Biax Lamp volts: 60V Wattage: 9W : G Rated life: 67 h Packing: 0 UVA Blacklight Biax L Lamp volts: 06V Wattage: 6W : G Rated life: 80 h Packing: 0 Insect Control Specialty Quartz Heat Lamp volts: 0 600V Wattage: 00 800W : Slv, R7s, CER Rated life: 000 h Packing: 6, Airfield Lamp volts: 6.6A to 0V Wattage: 0 000W : Various Rated life: 0 000 h Packing: Various Specialty Industrial Heating Airfield 6 6
Specialty lamps Lamps / Special Solutions Lamps Entertainment Lamps Health and Safety Specialty Lamps / Special Solutions Specialty Lamps lamps Entertainment Lamps Industrial Heating Volts Peak Wavelength (nm) Volts UVC Germicidal T/T8 9 G G T8 6607.8 9 000. G G T8 6608 7. 9 000. 0 98 G G0 T8 6609. 9 000 899. 90.6 87 G G T8 HO 660 9 9 000 899. 90.6 Volts Black Light T8 Peak Wavelength (nm) min max Quartz Heat 00 0 R7S QH00T/CL/7 787 00 000 0. 000 0-0 Slv QH000T/CL 7 00 000 00 Slv QH00T/CL 0 000.8 00 Slv QH00T/CL/HT 0 000.8 6 600 0-0 R7S QH600T/CL/7 69 00 000 98. 6 600 0-0 Slv QH600T/CL 688 00 000 0 7 000 0-0 Slv QHM/T/CL/HT 790 0 000 0.8 8 000 0-0 CER QHMT/CL/HT/R 76 0 000. 9 00 60-00 Slv QH00T/CL 88 00 000 7 6 60 80 Slv QH60/CL/ 087 00 000 07 6 6 800 0-600 Slv QH800/CL 87 00 000 06 6 6 min max G FT8/BL 68 * 987 68 7 00.. * Will be delisted without direct substitute Airfield Insect Control Volts Volts UVA Blacklight Biax Internal Starter Initial UVA Irradiance (mw/cm @ 0cm) Peak Wavelength (nm) 9 60 G F9BX BL G 9 0 68 67 0 0 UVA Blacklight Biax L External Starter 6 06 G F6BX BL G 90 80 68 80.8 0 Airfield Lighting 0 6.6A Gz9. Pin EXL 78 7 000. 0 6.6A Gz9. Pin EXM 8 70 000. 6.6A Mycalex cap & Prefocus collar AF6/ 6.6A W 880 760 600 00 00 6.6A Mycalex cap & Prefocus collar AF 6/T 6.6A 00W 887 00 600 60 00 00 6.6A Scrw Term Q6.6A/PAR6/ 79 NA 000 00 6.6A Mycalex cap & Prefocus collar AF7/ 6.6A 00W 88 800 600 00 00 6.6A D.C.Bay Q6.6AT/DCR 860* 0 00 6 6 00 6.6A Special Ribbon Leads Q6.6A/T/CL 87 000 00 76 7 00 0A Mog End Pr GX6d Q0A/PAR6/C 8 NA 00 7 8 99 0A Scrw Term Q0A/PAR6/ 86 NA 00 9 000 0 G8 Mog BiPost IM T0BP 88 000 00 0 * While stock lasts Specialty explanation For further information check the glossary FT8 / BL 68 Specialty (F) Identifies the lamp as Fluorescent (T8) Identifies the lamp s wattage and diameter (BL) Identifies product type 6 7 8 9 0 6 7 8 9 0 66 67
Drawings All cap drawings are a guide, if further technical details are required please contact your nearest sales office. B B E E7 E0 G G G. G8. G9 G0q G G G G8 GU GU. GU6. GU0 GX. GX9. GX0 GX6d GY6. GY9. GY9./ G6. Heat Sink GZ6. GZ9. G7 G G Gd- Gd- Gd- PGJX8 PGJX0 GR8 GR0q GRY0q- GRZ0d GRZ0t Gq- Gq- Gq- GXd- GXd- GXd- Cylinder DC Bay P0s P8s Ferule Screw Ext. Mog End Pr Terminal GX6d Mog End Pr GX6d R7s SFa- SFc 0- SFc 0.-6 X Ribbon Leads s / Glossary GXq- GXq- GXq- GXq- GXq- GXq-6 s / Glossary 68 69
Glossary s / Glossary A Accent Lighting Directional lighting to emphasize a particular object or draw attention to a display item. Adaptation The process by which the human eye adjusts to a change in light level. Ambient Lighting The general lighting present in an area -excluding task lighting and accent lighting but including general lighting and daylight streaming in. Amperes ( Amps. ) A measure of electrical current. In incandescent lamps, the current is related to voltage and power as follows: Watts (power) = Volts x Amps (current). American National Standards Institute (ANSI) A consensus-based organization which coordinates voluntary standards for the physical, electrical and performance characteristics of lamps, ballasts, luminaires and other lighting and electrical equipment. ANSI s These are -letter codes assigned by the American National Standards Institute. They provide a system of assuring mechanical and electrical interchangeability among similarly coded lamps from various manufacturers. General Electric uses the assigned ANSI s as Lamp Ordering s for most Projection Lamps Arc A general term for a high intensity electrical discharge occurring between two electrodes in a gaseous medium, usually accompanied by the generation of heat and the emission of light (See ELECTRICAL DISCHARGE). Arc Lamp A light source containing an arc (see above). Also called a discharge lamp, or an arc discharge lamp (See ELECTRICAL DISCHARGE). B Ballast An auxiliary piece of equipment required to start and to properly control the flow of current to gas discharge light sources such as fluorescent and high intensity discharge (HID) lamps. Ballast Losses Power or energy dissipated in the ballast as heat and not converted to lamp energy. Base or Socket The socket is the receptacle connected to the electrical supply; the base is the end of the lamp that fits into the socket. There are many types of bases used in lamps, screw bases being the most common for incandescent and HID lamps, while bi-pin bases are common for linear fluorescent lamps. Base Temperature (Maximum) The maximum operating temperature permitted for the base in Celsius. Fixture manufacturers need to ensure that these conditions are satisfied in their fixture. Bayonet A style of bulb base which uses keyways instead of threads to connect the bulb to the fixture base. The bulb is locked in place by pushing it down and turning it clockwise. Beam Angle The angular dimension of the cone of light from reflectorized lamps (such as R and PAR types) encompassing the central part of the beam out to the angle where the intensity is 0% of maximum. The beam angle sometimes called beam spread is often part of the ordering code for the reflectorized lamps. Example: The 0PAR0/HIR/NFL is a 0 watt PAR0 narrow flood lamp with a beam angle of degrees (See FIELD ANGLE). Beam Lumens The total lumens present within the portion of the beam contained in the beam angle. Beam Spread (Approximate) For reflector type lamps. The total angle of the directed beam (in degrees horizontal or vertical) to where the intensity of the beam falls to 0% or 0% of the maximum candlepower value as indicated. Bi-Pin Any base with two metal pins for electrical contact. This is the typical base for a fluorescent tube of to feet in length. It consists of prong contacts which connect into the fixture. Medium bi-pins are used with type T-8 and T- tubular fluorescent lamps, and miniature bi-pins are used for tubular T- fluorescent lamps. Biax GE trademark for its biaxial family of high efficiency and long-life compact fluorescent lamps. DBX (Double Biax), TBX (Triple Biax) and QBX (Quad Biax) refer to the number of U-shaped legs present in the lamp Black Light A popular term referring to a light source emitting mostly near UV (0 to 00 nm) and very little visible light. Bulb A loose way of referring to a lamp. Bulb refers to the outer glass bulb containing the light source. C Candela (cd) The measure of luminous intensity of a source in a given direction. The term has been retained from the early days of lighting when a standard candle of a fixed size and composition was defined as producing one candela in every direction. A plot of intensity versus direction is called a candela distribution curve and is often provided for reflectorized lamps and for luminaires with a lamp operating in them. acitor Device in an electronic circuit (part of ballast or a separate element) that stores electrical energy. Often used for power factor correction and lamp regulation. Centre Beam Candlepower (CBCP) Refers to the luminous intensity at the center of the beam of a blown or pressed reflector lamp (such as a PAR lamp). Measured in candelas. Ceramic Metal Halide (CMH) A type of metal halide lamp that uses a ceramic material for the arc tube instead of glass quartz, resulting in better colour rendering (>80 CRI) and improved lumen maintenance. GE ConstantColor CMH lamps feature a -piece arc tube design that delivers excellent colour consistency and lamp reliability. Chip A very small square of semi-conducting material. Also known as a die, it is the active light-emitting component of an LED. Chromaticity Measure to identify the colour of a light source, typically expressed as (x,y) coordinates on a chromaticity chart (See COLOUR TEMPERATURE). Chromaticity Coordinates A system for measuring the colour of the light emitted from a light source-either a primary source like a lamp or a secondary source like an illuminated object. Usually two numbers, x and y coordinates ranging from 0 to specify the chromaticity. Colour Bin LEDs are often sorted according to their CIE chromaticity coordinates into different groupings or bins. Colour Rendering Index (CRI) An international system used to rate a lamp s ability to render object colours. The higher the CRI (based upon a 0-00 scale) the richer colours generally appear. CRI ratings of various lamps may be compared, but a numerical comparison is only valid if the lamps are close in colour temperature. CRI differences among lamps are not usually significant (visible to the eye) unless the difference is more than - points. Colour Temperature (Correlated Colour Temperature - CCT) A number indicating the degree of yellowness or blueness of a white light source. Measured in Kelvins, CCT represents the temperature an incandescent object (like a filament) must reach to mimic the colour of the lamp. Yellowish-white ( warm ) sources, like incandescent lamps, have lower colour temperatures in the 700K-000K range; white and bluish-white ( cool ) sources, such as cool white (00K) and natural daylight (6000K), have higher colour temperatures. The higher the colour temperature the whiter, or bluer, the light will be (See CHROMATICITY). Compact Fluorescent Lamp (CFL) The general term applied to fluorescent lamps that are single-ended and that have smaller diameter tubes that are bent to form a compact shape. Some CFLs have integral ballasts and medium or candelabra screw bases for easy replacement of incandescent lamps. ConstantColor A GE registered name for lamp families that show very little colour shift over life, such as GE s Precise MR6 lamps and GE s Ceramic Metal Halide (CMH) lamps. Cool White A term loosely used to denote a colour temperature of around 00 K or higher. The Cool White (CW) designation is used specifically for T and other fluorescent lamps using halophosphors and having a CRI of 6. covrguard A lamp encased by a plastic sleeve or coating to help contain glass fragments if the lamp breaks. Current Type (AC/DC) Whether the operational voltage is based on Alternating Current or Direct Current. D Daylight Harvesting Lighting design for building interiors that makes use of daylight as a way of reducing energy consumption. Daylight Lamp A lamp resembling the colour of daylight, typically with a colour temperature of 00 K to 600K. Declaration of Conformity (DoC) A self-declaration of a product on its compliance to the Electromagnetic Compatibility Directive and the Low Voltage Directive and it can bear CE conformity marking (EU). Dichroic Reflector (or Filter) A reflector (or filter) that reflects one region of the spectrum while allowing the other region(s) to pass through. A reflector lamp with a dichroic reflector will have a cool beam i.e. most of the heat has been removed from the beam by allowing it to pass through the reflector while the light has been reflected. Die See Chip. Dimmable Whether or not the lamp lumens can be varied while maintaining reliability. Dimmer, Dimming Control A device used to lower the light output of a source, usually by reducing the wattage it is being operated at. Dimming controls are increasing in popularity as energy conserving devices. s / Glossary 70 7
Glossary s / Glossary Discharge Lamp A lamp where light is emitted from an electrical discharge between two electrodes as opposed to a filament lamp. Examples are: Fluorescent lamps and HID (High Intensity Discharge) lamps like Metal Halide, Mercury and High Pressure Sodium. All discharge lamps require some kind of current limiting device, e.g. a ballast, to operate them. Driver Control gear for LED-based products. Can be either constant current or constant voltage. For LED lamps the driver is often integral (see Self Ballasted Lamps ). E Efficacy A measurement of how effective the light source is in converting electrical energy to LUMENS of visible light. Expressed in LUMENS-PER-WATT (LPW) this measure gives more weight to the yellow region of the spectrum and less weight to the blue and red region where the eye is not as sensitive. Efficiency The efficiency of a light source is simply the fraction of electrical energy converted to light, i.e. watts of visible light produced for each watt of electrical power with no concern about the wavelength where the energy is being radiated. For example, a 00 Watt incandescent lamp converts 7% of the electrical energy into light; discharge lamps convert % to 0% into light. The efficiency of a luminaire or fixture is the percentage of the lamp lumens that actually comes out of the fixture (See LUMINOUS EFFICACY). Efficiency of Ballast The ratio of output power divided by input power. A premium ballast would have an electrical efficiency greater than 90%. The efficiency of a luminaire or fixture is the percentage of the lamp lumens that actually comes out of the fixture. e-hid ballast (see ELECTRONIC HID BALLAST). ELC (European Lamp Companies Federation) Created in 98, the European Lamp Companies Federation (ELC) is both the forum and the voice of the lamp industry in Europe. It represents the leading European lamp manufacturers, which collectively directly employ 0 000 people, and account for 9 percent of total European production, with an annual turnover in Europe of billion. From the outset, ELC objectives have been to promote efficient lighting practice for a sustainable environment and the advancement of human comfort, health and safety. To this end, ELC monitors, advises and co-operates with legislative bodies in developing European Directives and Regulations relevant to the European lamp industry. Electrical Discharge A condition under which a gas becomes electrically conducting and becomes capable of transmitting current, usually accompanied by the emission of visible and other radiation. An electric spark in air is an example of an electrical discharge, as is a welder s arc and a lightning bolt. (See ARC, ELECTRODELESS LAMPS) Electrode Any metal terminal emitting or collecting charged particles, typically inside the chamber of a gas discharge lamp. In a fluorescent lamp, the electrodes are typically metal filaments coated with special powders called emission mix. Negatively charged free electrons emitted by one electrode are attracted to the positive electrode (anode), creating an electric current and arc between electrodes. Electromagnetic Ballast (See MAGNETIC BALLASTS). Electromagnetic Inference (EMI) High frequency electronic ballasts and other electronic devices can produce a small amount of radio waves which can interfere with radio and TV. Federal mandated requirements must be met for EMI levels before an electronic device is considered FCC compliant (US). (FCC is the Federal Communications Commission). Electromagnetic Spectrum A continuum of electric and magnetic radiation that can be characterized by wavelength or frequency. Visible light encompasses a small part of the electromagnetic spectrum in the region from about 80 nanometers (violet) to 770 nanometers (red) by wavelength. Electronic Ballast A short name for a fluorescent high frequency electronic ballast. Electronic ballasts use solid state electronic components and typically operate fluorescent lamps at frequencies in the range of - khz. The benefits are: increased lamp efficacy, reduced ballast losses and lighter, smaller ballasts compared to electromagnetic ballasts. Electronic ballasts may also be used with HID (High Intensity Discharge) lamps (See ELECTROMAGNETIC BALLAST). Electronic HID Ballast An electronic ballast capable of operating an HID lamp. GE s UltraMax (electronic HID ballast) operates PulseArc (metal halide) and CMH (Ceramic Metal Halide) lamps between 0W and 00W and provides higher efficiency and significantly improved lumen maintenance over magnetic ballasts. Enclosed Fixtures (See OPEN FIXTURE RATED) -Using s (EuP) The EuP Directive establishes a framework for the setting of eco-design requirements for energy-using products. It aims to improve the environmental performance of products throughout the life-cycle, by systematic integration of environmental aspects at a very early stage in the product design. Eye Sensitivity A curve depicting the sensitivity of the human eye as a function of wavelength (or colour). The peak of human eye sensitivity is in the yellow-green region of the spectrum. The normal curve refers to photopic vision or the response of the cones. (See Photopic, Scotopic, Fovea, Foveal vision) F Filament Design Filaments are designated by a letter combination in which C is a coiled wire filament, CC is a coiled wire that is itself wound into a larger coil, and SR is a straight ribbon filament. Numbers represent the type of filament support arrangement. Fixture Requirements Describes fixture requirements for HID lamps O = Open or Enclosed Fixtures E = Enclosed Fixtures Only S = Lamps operated in a vertical position (Base Up or Down) ±º, can be used in an open fixture. Lamps burned in any other orientation must be used in enclosed fixtures only. Flicker The periodic variation in light level caused by AC operation that can lead to strobe effects. Flood Used to refer to the beam pattern of a reflector lamp, which disperses the light over a wide beam angle, typically 0 degrees or more. ( Flood as opposed to Spot ) Floodlight A luminaire used to light a scene or object to a level much brighter than its surroundings. Usually floodlights can be aimed at the object or area of interest. Fluorescence A physical phenomenon whereby an atom of a material absorbs a photon of light and immediately emits a photon of longer wavelength. If there is a significant delay the phenomenon is called phosphorescence rather than fluorescence. It is interesting that phosphors used in lamps exhibit fluorescence, not phosphorescence. (See PHOSPHOR). Fluorescent Lamp A high efficiency lamp utilizing an electric discharge through low pressure mercury vapour to produce ultraviolet (UV) energy. The UV excites phosphor materials applied as a thin layer on the inside of a glass tube which makes up the structure of the lamp. The phosphors transform the UV to visible light. Forward Current Current through an LED in the direction of its greatest conduction. Forward Voltage (VF) The voltage across an LED for a given forward current. Four-Pin Compact Fluorescent Lamps A plug-in Compact Fluorescent Lamp with pins in the base to make electrical contact with the ballast. Four-pin lamps can be dimmed on appropriate dimming ballasts while two-pin lamps cannot. Frequency Rate of alternation in an AC current. Expressed in cycles per second or Hertz (Hz). Full Spectrum Lighting A marketing term, typically associated with light sources that are similar to some forms of natural daylight (000K and above, 90+ CRI), but sometimes more broadly used for lamps that have a smooth and continuous colour spectrum. G Genura GE s electrodeless compact fluorescent lamp, Genura, uses induction to power the discharge. The chamber generates UV (just like a discharge in a regular fluorescent lamp) that is converted by phosphors to visible light. Because Genura uses no electrodes, the life of this unique reflector lamp is longer than typical compact fluorescent products (see INDUCTION LIGHTING). Glare Visual discomfort caused by excessive brightness is called discomfort glare. If task performance is affected it is called disability glare. Glare can be direct glare or indirect (reflected) glare (See VEILING REFLECTIONS and VISUAL COMFORT PROBABILITY). Group Relamping The practice of replacing all the lamps at an installation at one time with new lamps when the lamps have operated for (typically) 6% to 70% of rated life. The two benefits of group relamping are: () reduced maintenance costs because of the expense and inconvenience of replacing failing lamps one at a time, and () improved appearance and performance since older lamps are often degrading in brightness and colour as they age. H Halogen Lamp A halogen lamp is an incandescent lamp with a filament that is surrounded by halogen gases, such as iodine or bromine. Halogen gases allow the filaments to be operated at higher temperatures and higher efficacies. The halogen participates in a tungsten transport cycle, returning tungsten to the filament and prolonging lamp life. s / Glossary 7 7
Glossary s / Glossary Halogen-IR (HIR ) Lamp GE designation for high-efficiency tungsten halogen lamps. HIR lamps utilize shaped filament tubes coated with numerous layers of materials that transmit light but reflect the heat (infrared) back into the filament. This reduces the power needed to keep the filament hot. High-Bay Lighting Lighting designed for (typically) industrial locations with a ceiling height of 7. metres and above. High Intensity Discharge (HID) Lamp A general term for mercury, metal halide and high-pressure sodium lamps. HID lamps contain compact arc tubes which enclose various gases and metal salts operating at relatively high pressures and temperatures. High Power Factor A ballast or lamp with integral electronics whose power factor is corrected to 90% or greater. High-Pressure Sodium (HPS) Lamp HPS lamps are high intensity discharge light sources that produce light by an electrical discharge through sodium vapour operating at relatively high pressures and temperatures. GE markets these lamps under the trade name of Lucalox. Hot Restart Time Time it takes for a High Intensity Discharge lamp to reach 90% of light output after going from on to off to on. I Ignitor An electronic device providing a high voltage pulse to initiate an electrical discharge. Typically, the ignitor is paired with or is a part of the ballast (See STARTER). Illuminance The density of light (lumens/area) incident on a surface; i.e. the light level on a surface. Illuminance is measured in footcandles or lux. Illuminance Meter A device that measures the illuminance at a location calibrated either in footcandles or in lux. (Also know as a light meter - See COSINE CORRECTED). Incandescent Lamp A light source that generates light utilizing a thin filament wire (usually of tungsten) heated to white heat by an electric current passing through it. Indirect Lighting The method of lighting a space by directing the light from luminaires upwards towards the ceiling. The light scattered off the ceiling produces a soft, diffuse illumination for the entire area. Infrared Radiation Electromagnetic energy radiated in the wavelength range of about 770 to,000,000 nanometers. in this range cannot be seen by the human eye, but can be sensed as heat by the skin. Input Voltage Power supply voltage required for proper operation of fluorescent or HID ballast. Input Watts The total power input to the ballast that includes lamp watts and ballast losses. The total power input to the fixture is the input watts to the ballast or ballasts and is the value to be used when calculating cost of energy and air conditioning loads. More than 90% of the input watts is wattage or power delivered to the lamp load with typical ballast. Integral A popular term for a lamp which includes a built-in ballast (CFL or HID), driver (LED) or transformer (halogen). Intensity Bin LEDs are often sorted according to their luminous intensity values into different groupings or bins. Inverse Square Law Formula stating that if you double the distance from the light source, the light level goes down by a factor of, if you triple the distance, it goes down by a factor of 9, and so on. Isocandela Plot A plot with lines connecting points of equal luminous intensity around a source. Isolux Plot (or Isofootcandle Plot) A line plotted to show points of equal illuminance (lux or footcandles) on a surface illuminated by a source or sources. K Kelvin A unit of temperature starting from absolute zero, parallel to the Celsius (or Centigrade) scale. 0C is 7K. Kilowatt (kw) The measure of electrical power equal to 000 watts. Kilowatt Hour The standard measure of electrical energy and the typical billing unit used by electrical utilities for electricity use. A 00-watt lamp operated for 0 hours consumes 000 watt-hours (00 x 0) or one kilowatt-hour. If the utility charges $.0/ kwh, then the electricity cost for the 0 hours of operation would be 0 cents ( x $.0) L Lamp The term used to refer to the complete light source package, including the inner parts as well as the outer bulb or tube. Lamp, of course, is also commonly used to refer to a type of small light fixture such as a table lamp. Lamp Current Crest Factor Ratio of peak lamp current to RMS or average lamp operating current. Lamp Height Referenced by IEC as Dimension C. Also referred to as Base Face to Top of Lamp. Lamp Types Filament lamps: Incandescent, Halogen, Halogen-IR. Discharge Lamps: Fluorescent, HID (High Intensity Discharge) HID Lamps: Mercury, HPS (High Pressure Sodium), MH (Metal Halide) and CMH (Ceramic Metal Halide) LED Lamps Lamp Width Referenced by IEC as Dimension A. Lens A transparent or semi-transparent element which controls the distribution of light by redirecting individual rays. Luminaires often have lenses in addition to reflectors. Life (See RATED LAMP LIFE). Light Radiant energy that can be sensed or seen by the human eye. Visible light is measured in lumens. Light Centre Length (L.C.L.) The distance between the centre of the filament, or arc tube, and a reference plane - usually the bottom of the lamp base. Light Emitting Diode (LED) A solid that directly converts electrical impulses into light. Most white light LEDs incorporate phosphors to change the colour characteristics of the emitted light. Lighting Industry Federation (LIF) For Stage & Studio lamps, these are assigned by the Lighting Federation of London U.K. They ensure electrical and mechanical interchangeability of similarly coded lamps. LIF codes are divided into groups according to the primary application of the lamps. Light Loss Factor The product of all factors that contribute to lowering the illumination level including reflector degradation, dirt, lamp depreciation over time, voltage fluctuations, etc. Light Meter (See ILLUMINANCE METER) Light Pollution Light that is directed to areas where it is not needed, and thereby interferes with some visual act. Light pollution directed or reflected into the sky creates a dome of wasted light and makes it difficult to see stars above cities. Lucalox The GE brand name for High Pressure Sodium lamps. Lumens A measure of the luminous flux or quantity of light emitted by a source. For example, a dinner candle provides about lumens. A 60-watt Soft White incandescent lamp provides about 80 lumens. Lumen Depreciation, Lumen Maintenance A measure of how well a lamp maintains its light output over time. It may be expressed numerically or as a graph of light output vs. time. The mean lumens of a lamp is the lumens at 0% of rated life (0% for HPS lamp). Lumens Per Watt (LPW) A ratio expressing the luminous efficacy of a light source. Average efficacy of lighting technologies: Incandescent - Halogen - CFL 0-70 Metal Halide 6-0 HPS 70-0 Fluorescent 0-0 LED 0-0 Note: The values above for discharge lamps do not include the effect of the ballasts, which must be used with those lamps. Taking ballast losses into account reduces system or lamp ballast efficacies typically by 0-0% depending upon the type of ballast used. Luminaire A complete lighting unit consisting of a lamp (or lamps), ballast (or ballasts) as required together with the parts designed to distribute the light, position and protect the lamps and connect them to the power supply. A luminaire is often referred to as a fixture. Luminaire Efficiency The ratio of total lumens emitted by a luminaire to those emitted by the lamp or lamps used in that luminaire. Also commonly referred to as Light Output Ratio or LOR. Luminance A measure of surface brightness when an observer is looking in the direction of the surface. It is measured in candelas per square meter (or per square foot) and was formerly referred to as photometric brightness. Luminous Efficacy The light output (lumens) of a light source divided by the total power input (watts) to that source. It is expressed in lumens per watt (see LUMENS PER WATT). Luminous Intensity A measure of the visibility of a light source generally expressed in candelas. It is defined as luminous flux per unit solid angle (steradian) in a given direction. Lux (lx) A unit of illuminance or light falling onto a surface. One lux is equal to one lumen per square meter. Ten lux approximately equals one footcandle. (See FOOTCANDLE) M Magnetic Ballast A ballast used with discharge lamps that consists primarily of transformer-like copper or aluminum windings on a steel or iron core. Also called Core & Coil (see ELECTRONIC BALLASTS). Maximum Overall Length (M.O.L.) The end-to-end measurement of a lamp, expressed in inches or millimeters. s / Glossary 7 7
Glossary s / Glossary Mean Lumens The average light output of a lamp over its rated life. Based on the shape of the lumen depreciation curve, for fluorescent and metal halide lamps, mean lumens are measured at 0% of rated lamp life. For mercury, High Pressure Sodium and incandescent lamps, mean lumen ratings refer to lumens at 0% of rated lamp life (See LUMEN MAINTENANCE). Mercury Lamp A high-intensity discharge light source operating at a relatively high pressure (about atmosphere) and temperature in which most of the light is produced by radiation from excited mercury vapour. Phosphor coatings on some lamp types add additional light and improve colour rendering. Metal Halide Lamp A High Intensity Discharge light source in which the light is produced by the radiation from mercury, plus halides of metals such as sodium, scandium, indium and dysprosium. Some lamp types may also utilize phosphor coatings. Mesopic Typically referring to nighttime outdoor lighting conditions, the region between PHOTOPIC and SCOTOPIC vision (See SCOTOPIC). Monochromatic Light Light with only one wavelength (i.e. colour) present. Mortality Curve Lamps have a rated or expected life but individual failures occur earlier and some lamps will last longer. The mortality curve depicts the expected percent surviving in a group of lamps at various points between zero hours and rated life or beyond. The curve starts with 00% at zero hours and goes to 0% surviving at the rated life (e.g. 000 hours or 0 000 hours, etc.) However, the shape of the curve between these two end points can vary depending on the lamp type. Mounting Height Distance from the bottom of the fixture to either the floor or work plane, depending on usage. Multi-Vapor A GE brand name for metal halide lamps. N Nanometer A unit of wavelength equal to one billionth of a metre. O Open Fixture Rated Lamps that are approved for burning in open fixtures (as opposed to enclosed fixtures which have an acrylic lens or plate glass enclosure). Operating Position or Burn Position Mercury and High Pressure Sodium lamps may be operated in any burn position and will still maintain their rated performance specifications. Metal Halide and Low Pressure Sodium lamps, however, are optimized for performance in specific burn positions, or may be restricted to certain burn positions for safety reasons. U = Universal burning position HBU = Horizontal -º to Base Up HBD = Horizontal +º to Base Down HOR = Horizontal ±º H = Horizontal to -º only VBU = Vertical Base Up ±º VBD = Vertical Base Down ±º If no special burn position is noted, the burn position is universal. Operating Voltage For electrical discharge lamps, this is the voltage measured across the discharge when the lamp is operating. It is governed by the contents of the chamber and is somewhat independent of the ballast and other external factors. P PAR Lamp PAR is an acronym for parabolic aluminized reflector. A PAR lamp, which may utilize either an incandescent filament, a halogen filament tube or an HID arc tube, is a precision pressed glass reflector lamp. PAR lamps rely on both the internal reflector and prisms in the lens for control of the light beam. Phosphor An inorganic chemical compound processed into a powder and deposited on the inner glass surface of fluorescent tubes and some mercury and metalhalide lamp bulbs. Phosphors are designed to absorb short wavelength ultraviolet radiation and to transform and emit it as visible light (See FLUORESCENCE). Phosphors are also used in LED devices to create white light when used in combination with LEDs of certain wavelengths. Photometry The measurement of light and related quantities. Photopic Vision for which the cones in the eye are responsible; typically at high brightness and in the foveal or central region (See SCOTOPIC, FOVEA, FOVEAL VISON). Plug-In (See CFL). Potting Material used to completely surround and cover components of some magnetic and electronic ballasts. Potting compound fulfills functions of protecting components, dampening sound, and dissipating heat. Power Factor (PF) A measure of the phase difference between voltage and current drawn by an electrical device, such as a ballast or motor. Power factors can range from 0 to.0, with.0 being ideal. Power factor is sometimes expressed as a percent. Incandescent lamps have power factors close to.0 because they are simple resistive loads. The power factor of a fluorescent and HID lamp system is determined by the ballast used. High power factor usually means a rating of 0.9 or greater. Power companies may penalize users for using low power factor devices. Power Factor Corrected Ballasts that incorporate a means of Power Factor Correction yielding power factor of 90% or greater. Precise The GE trade name for the compact MR-6 and MR- low-voltage halogen dichroic cool beam reflectorized spot and flood lamps. Q Quad Generally refers to a compact fluorescent lamp containing U-shaped tubes. Quartz A name for fused silica or melted sand from which many high-temperature containers are fashioned in the lighting industry. Quartz looks like glass but can withstand the high temperatures needed to contain high intensity arc discharges. Quartz-Halogen Lamp (See HALOGEN LAMPS). Quartzline A GE registered trademark term for some types of halogen lamps. R Radiation A general term for the release of energy in a wave or ray form. All light is radiant energy or radiation, as is heat, UV, microwaves, radio waves, etc. Rated Lamp Life For most lamp types, rated lamp life is the length of time of a statistically large sample between first use and the point when 0% of the lamps have died. It is possible to define useful life of a lamp based on practical considerations involving lumen depreciation and colour shift and also on the need to reduce lamp replacement costs (See GROUP RELAMPING). For GE LED products, rated life is quoted (unless where indicated otherwise), as the L70 value. This refers to the time taken to reach 70% of initial lumen output. This is the emerging industry standard for LED products. Reflectance The ratio of light reflected from a surface to that incident upon it. Reflector Lamp (R) A light source with a built-in reflecting surface. Sometimes, the term is used to refer specifically to blown bulbs like the R and ER lamps; at other times, it includes all reflectorized lamps like PAR and MR. Most LED lamps are also replacements for reflector lamps, even if they do not physically have a reflector as part of their construction. S Scotopic Vision where the rods of the retina are exclusively responsible for seeing, typically like the light levels in the countryside on a moonless, starlit night (See also PHOTOPIC, FOVEA, FOVEAL VISION MESOPIC). Screw-In (See CFL ). Seal Temperature (Maximum) The maximum operating temperature of the seal of the lamp in Celsius. Self-Ballasted Lamps A lamp with an integral ballasting device allowing the lamp to be directly connected to a socket providing line voltage (See CFL). Series Lamp Operation Refers to ballasts that employ a single current path passing through all lamps operated by the ballast. If one lamp should fail, companion lamps operated by the same ballasts will also extinguish or dim. Spectral Power Distribution (SPD) A graph of the radiant power emitted by a light source as a function of wavelength. SPDs provide a visual profile or finger print of the colour characteristics of the source throughout the visible part of the spectrum. Spectrum See SPECTRAL POWER DISTRIBUTION (SPD). Spiral Lamp GE trademark for its helical family of high efficiency, long-life Compact Fluorescent Lamps. Spot A colloquial term referring to a reflector lamp with a tight beam of light, typically around 0 degrees or less. It comes from the fact that such a lamp produces a narrow spot of light as opposed to a wide flood of light. Starter An electronic module or device used to assist in starting a discharge lamp, typically by providing a high-voltage surge (See IGNITOR). Starting Temperature (Minimum) The minimum ambient temperature at which the lamp will start reliably. System A term referring to the lamp and ballast combination, and sometimes to the entire lighting delivery system including the fixture, the optics, the thermal management system, the particular layout and the lighting controls. T T, T8, T A designation for the diameter of a tubular bulb in eighths of an inch; T is eighths of an inch, or -/ inches; T8 is inch, and so on. s / Glossary 76 77
Glossary Sales Offices Task Lighting Supplemental lighting provided to assist in performing a localized task, e.g. a table lamp for reading or an inspection lamp for fabric inspection. Troffer A long, recessed lighting unit, usually installed in an opening in the ceiling. Tungsten-Halogen Lamp (See HALOGEN LAMP). Two-Pin Compact Fluorescent Lamps Type of lamps that have the glow bottle starter built into the base of the lamp. Traditionally -pin lamps are designed to work with electromagnetic ballasts (see FOUR-PIN COMPACT FLUORESCENT LAMPS). U Ultra A common way of referring to highefficiency. Ultraviolet (UV) Radiation For practical purposes, any radiant energy within the range of 00 80 nanometers. It is beyond the blue or violet region of the spectrum, and is invisible to the eye just like the silent ultrasound dog whistle is inaudible to the ear. UV is divided into regions: UVA 00 to 80 nm UVB 80 to nm UVC to 00 nm Some wavelengths (80 0) produce ozone, some (0 00) are bactericidal, some (80 0) erythemal (redden human skin); others (0 00) cause secondary luminance (black light). V Volt A measure of electrical pressure between two points. The higher the voltage, the more current will be pushed through a resistor connected across the points. The volt specification of an incandescent lamp is the electrical pressure required to drive it at its designed point. The voltage of a ballast (e.g. 77 V) refers to the line voltage it must be connected to. Voltage A measurement of the electromotive force in an electrical circuit or device expressed in volts. Voltage can be thought of as being analogous to the pressure in a waterline. Voltage (Design) For Automotive lamps, voltage at which the lamp is designed to provide the amperes, candlepower, and laboratory life characteristics. For Projection lamps, the voltage shown is the design voltage of the lamp, on which the life and wattage ratings are based. Lamps are available only in the design voltage(s) shown. When ordering lamps listed for more than one voltage, be sure to specify the voltage required. (Supply voltage variation can significantly affect lamp life.) Voltage Surge Transient spikes in line voltage that can be harmful to electronic equipment like computers and electronic ballasts. Surge suppressors are often used to protect against such transients. W Wall Temperature (Maximum Bulb) The maximum operating bulb wall temperature in Celsius. Warm Up Time to 90% The time it takes for a High Intensity Discharge lamp to reach 90% of light output after being turned on. Warm White Refers to a colour temperature around 000K, providing a yellowish-white light. Watt A unit of electrical power. Lamps are rated in watts to indicate the rate at which they consume energy (See KILOWATT HOUR). Watt-Miser A Watt-Miser lamp is a term used by GE to indicate a reduced-wattage lamp with performance characteristics (life, light output, etc.) such that it can usually directly replace a higher-wattage product. Watt-Miser lamps are available in a wide range of incandescent and fluorescent lamp types. Wavelength The distance between two neighboring crests of a traveling wave. The wavelength of visible light is between 00 and 700 nanometers. WEEE (Waste Electrical and Electronic Equipment) The Waste Electrical and Electronic Equipment Directive (WEEE Directive) aims to minimise the impact of electrical and electronic goods on the environment, by increasing re-use and recycling and reducing the amount of WEEE going to landfill. It seeks to achieve this by making producers responsible for financing the collection, treatment, and recovery of waste electrical equipment, and by obliging distributors to allow consumers to return their waste equipment free of charge. AUSTRIA, GERMANY & SWITZERLAND GE Lighting GmbH Bleichstrasse 6-66 60 Frankfurt/M. Germany Tel: +9 69 0 8 Fax: +9 69 0 9 BULGARIA VSD Merkur Eood Nikola Haitov Str. Office ent. Sofia, Bulgaria Tel: + 9 87086 BOSNIA AND HERZEGOVINA, CROATIA & SLOVENIA Media Light d.o.o. Exclusive agent of GE Hungary Kft. Lighting and Power Protection Cesta na Brdo 09 000 Ljubljana Slovenia Tel: +86 0 66 Fax: +86 0 6 FRANCE & BENELUX Citylights 0, rue du rondpoint du Pont de Sèvres 900 Boulogne-Billancourt France HUNGARY GE Hungary Kft. 0 Budapest Vaci ut 77. Tel: +6 99 00 Fax: +6 99 67 ITALY GE Lighting Srl Centro Dir. Colleoni Palazzo Andromeda B P via Paracelso 6 086 Agrate Brianza (MB) N. Verde Nord 800 97780 N. Verde Centro - Sud 800 9778 Tel: +9 0 707700 Fax: +9 0 707777 MACEDONIA VSD Merkur DOO Skopje Ul. Vasil Glavinov 7B/ 000 Skopje Macedonia Tel: + 89 790 Fax: + 89 797 ROMANIA & MOLDOVA SC VSD Merkur Lighting Group SRL: Strada Luncsoara nr. Parter Birou, Ap. 0 Bucharest, Romania Tel: +0 78 60 RUSSIA GE Rus LLC 0C, Presneskaya nab. 7, Russia Tel: +7 9 79 699 SERBIA & MONTENEGRO VSD Merkur Group DOO Bulevar Mihajla Pupina 0D/0 070 Novi Beograd Serbia Tel: + 8 97 SPAIN & PORTUGAL GE Lighting Appliances España S.A. Calle Gobelas -7 La Florida, 80, Madrid Spain Tel: 900 99 6 Fax: 900 99 609 SWEDEN GE Lighting AB, FE 06 Vendevägen 89 SE-8 8 Stockholm, Sweden Tel: +6 8 99 Fax: +6 8 99 TURKEY General elektrik Türk Ltd.Şti Reşitpaşa Mah.Eski Büyükdere Cad.Windowist Tower No:6 Kat:7 Maslak 67 Sarıyer /İstanbul Türkiye Tel: +90 769-77 Fax: +90 760 UNITED KINGDOM The Ark 0 Talgarth Road London W6 8BJ United Kingdom Tel. + 800 69 890 Fax: + 800 69 88 Warm-Up Time HID lamps typically take a few minutes to warm up to full brightness after starting. s / Glossary For further information please contact your sales person or visit us on the web at: http://gelighting.com/eu 78 79 Sales Offices
www.gelighting.com/eu and General Electric are both registered trademarks of the General Electric Company