PROCEDURES PREVENTION OF ACCIDENTAL IGNITION



Similar documents
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Natural Gas Emergencies

HOT WORK PERMIT PROCEDURES

Notes. Material 1. Appropriate Flammable Liquids

ADMINISTRATIVE SERVICES MANUAL

Sample Written Program. For. Flammable Liquids

OSHA Office of Training and Education 1

Installation Instructions for Alarm Module Kit A043F059

Pressure Vessels (Air Compressors) and LPG Tanks

Presented by: Rich Perry Marsh Risk Consulting

Flammable and Combustible Liquids. Slide 1 (of 23)

Grounding and Bonding Against Static Electricity. Jon Koppari, CSP, MS Occupational Safety and Health Instructor OSHA Training Institute

HOT WORK PERMIT PROGRAM TRAINING. John Braun

Compressed Gas Cylinder Program

How To Stop A Gas Leak

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

National- Spencer Inc.

Compressed Gas Cylinder Storage and Handling Guide

tire inflator with pressure gauge

15GAL STEEL OIL DRAIN WITH 110V PUMP

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Spray Booth Guideline

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

3053 Electrical Safety Training Program Course Outline

Natural Gas Safety. What You Need to Know

Safe Operating Procedure

400 Amp Rechargeable Jump Start System RAC-HP082

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

CHAPTER X GAS LEAKAGE CONTROL GUIDELINES FOR PETROLEUM GAS SYSTEMS

San josé OWNER S MANUAL

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

exit routes and fire protection

FIRE EXTINGUISHER TRAINING

LCT 1025 (08/08) Copyright 2008 Harleysville Mutual Insurance Company Page 1 of 5 All rights reserved

Process Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices

Pressure Testing (Hydrostatic / Pneumatic) Safety Guidelines

A Job Safety Execution Plan is required. mixtures of the above called, natural gas liquids (NGL's) refined products and their components

During Various Aluminum Fabricating Operations

CARING FOR YOUR WATER HEATER

Emergency Plan. This emergency plan provides a format of data essential in an emergency situation.

natural gas Control control of of Natural Gas in Emergency Situations

FIRE SAFETY FOR OFFICE WORKERS

Standard Operating Procedure (SOP) Car/Truck Battery Safety

3 WATT LED SPOTLIGHT Model No. SLM

How To Safely Dig For Natural Gas

TWO BURNER PROPANE CAMPING STOVE

GUIDELINE FOR SAFETY IN THE HANDLING OF FLAMMABLE LIQUIDS

This leaflet provides information on

OPERATING ROOM SAFETY. Off-Site Locations

Fire Prevention Plan for Flynn Hall 1648 Musketeer Drive

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

All You Ever Wanted to Know About Fire Extinguishers...

Independent Contractor Policy

Fire Protection and Prevention

Take care with oxygen Fire and explosion hazards in the use of oxygen

FIRE PREVENTION PLAN

Emergency Response Guide

Fire Prevention Plan for Commons 1655 Musketeer Drive

Notes. Material 1. Personal Protective Equipment 2.

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

Compressed Gas Cylinder Safety

Company Name Chemical Spill Prevention & Clean-up Procedures Program. Last Revised On 00/00/0000

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

8" BENCH GRINDER OWNER'S MANUAL

Kidd Mine Barricade Standards

1.0 Purpose Definitions Hot Work Operations. 5

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Automotive and Diesel Lab Safety Guidelines

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

120Volt 60-70A ARC WELDER Rev

University of Tennessee Safety Guidelines

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

WEEKLY SAFETY MEETING All Euramax Subsidiaries WELDING SAFETY / HOT WORK SAFETY. Safety Meeting Contents. Meeting Notice.

OBSERVING BOILER SAFETY RULES

Stay Safe Around Electricity and Natural Gas Teacher s Guide

MOTOR FUEL DISPENSING SAFETY

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Instruction manual for Firstline FCS12000CH

Texas Department of Insurance. Fire Safety. Provided by. Workers Health & Safety. Pub. No. HS01-028D (7-08)

PBX Series Quick Fit Connector Bimetallic Steam Traps

OREGON FIRE CODE Interpretations and Technical Advisories

FIRE SAFETY HANDBOOK

NATURAL GAS PIPELINE SAFETY

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Operator s Manual. PUMP Model: PAC25 SAVE THIS MANUAL FOR FUTURE REFERENCE. Distributed by: Pacer Pumps

G670 Intermittent Pilot Ignition Controls

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

How To Keep An Eye On Electric Safety

October Safety Subject

Compressed Gas Cylinders Safety Policy

Notes. Material 1. Tools the employee is expected to operate

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

BP WIND ENERGY POLICIES AND PROCEDURES

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Transcription:

Page No: 1 of 7 6.0 PURPOSE (192.751) All possible precautions shall be exercised to prevent the accidental escape and ignition of gas. Whenever possible, potential sources of ignition should be eliminated prior to the commencement of work. 6.1 SCOPE A. Escaping Gas B. Leak Repair C. Static Electricity D. No Smoking E. Combustible Atmosphere F. Preventing Air from Entering 6.2 ESCAPING GAS HAZARDS AND PREVENTION OF IGNITION Escaping gas may follow a ditch or excavation for an appreciable distance if air currents are favorable, or if gas is blowing directly up at the ditch or excavation. The public must be kept a safe distance at all times even if the area must be roped off in order to do so. The following procedures are observed where sources of ignition may be involved: A. Post warning signs as appropriate, provide a fire extinguisher and remove all potential sources of ignition from the area when the presence of gas or the proposed venting of gas into the air may create a hazard of fire or explosion. B. Do not turn on electrical circuits, including flashlights not approved for a gaseous atmosphere, in an area where gas is present. Electrical tools, cords, and generators used with plastic fusion may also considered possible sources of ignition. C. Do not weld or gas cut pipe or other facilities containing a combustible mixture of gas in air. This does not prohibit the "Fire Controlled" tie-in method. This method allows the welding operation to go on while gas is present at slightly higher than atmospheric pressure. D. Precautions against possible ignition from static electricity in gaseous atmosphere are taken when work with plastic pipe is performed, i.e., purging operations, leak repairs or with broken or damaged lines.

Page No: 2 of 7 E. Use only lighting equipment approved for use in a gaseous atmosphere, including flashlights, in or adjacent to an area of possible ignition. F. Do not use open flames of any kind for the purpose of detecting and/or localizing gas leakage or suspected gas leakage in mains or services under any circumstances. Use combustible gas indicators and/or soap bubble testing to detect and/or localize leakage. G. The practice of "flashing" bell holes before entering them for the purpose of welding, etc. When flashing, do not flash bell holes containing plastic piping under pressure. Use a combustible gas indicator to detect gas leakage. 6.2 LEAK REPAIR A. Location of Vehicle Park Utility vehicles a safe distance from the leak. If wind is present, always park upwind from the leak. B. Warning the Public "No Smoking" signs, barricades and caution tape shall be posted (220 linear feet around the site). When on or near a public roadway, personnel shall be stationed on both sides of the restricted area to stop vehicles and to warn the public. They shall use red flags during the day and electric trouble lights at night. C. If the leak is major and is near a residence or business establishment occupants shall be contacted immediately and warned to extinguish all fires. D. Prepare for an Emergency Evaluate the situation. Be prepared for the worst before starting to repair even minor leaks. Check location of available valves, and work out any necessary shutdown and rerouting procedures. E. Have Tools and Supplies Ready

Page No: 3 of 7 Have the right tools and materials on the job before the leak is uncovered. Be sure the clamps, bolts, nuts, wrenches and other items are ready and in a handy and safe place. Be sure all threads are clean, oiled and in good condition. F. Take Steps to Prevent Fire Extinguish or move to safe distance all possible sources of ignition. Matches, cigarette lighters, friction lighter, etc., shall be left in the truck. G. Reduce Pressure When making repairs on high-pressure lines, gas pressure may be reduced as authorized by your supervisor. H. Prevent Sparks When using picks and shovels, be extremely careful to prevent striking sparks. I. Protect the Eyes Wear approved eye protection when excavating around the pipe, as well as when actually repairing the leak. J. Excavating Make the excavation large enough for ample working room around the pipe. Do not disturb the dirt covering the actual leak until the very last. This will minimize the amount of digging to be done while the leak is blowing. K. Stay Clear of Gas Always stay clear of a blowing stream of gas. Stand behind or to one side of the stream. L. Signaling Have prearranged signals to direct work in repairing a break or leak. The noise from

Page No: 4 of 7 a high-pressure leak makes hearing extremely difficult. Use approved ear protection when working on a high-pressure leak. M. Number of Employees The severity of the leak or line break will determine the number of employees required to safely control escaping gas. No person shall enter a gaseous atmosphere in a confined space without another person outside of the confined space. N. Fire Extinguishers A minimum of one 20-pound, dry chemical fire extinguisher, ABC, shall be kept in readiness while repairing a line break, making a tap on a hot line, during welding processes, or where any possible escape of natural gas and source of ignition might occur. Before work begins, the employee in charge shall designate one qualified individual to be responsible for the fire extinguisher. Procedure for using portable extinguisher: 1. Pull the pin 2. Aim low 3. Squeeze 4. sweep side to side and upward If gas is ignited decide as to whether to extinguish the fire or let it burn based on public safety O. Methods of Gas Flow Control 1. The following methods may be used to control gas flow: (a) (b) (c) (d) In-line valves. Pressure control (line stopper) fitting. Pipe squeezing. Repair clamps.

Page No: 5 of 7 (e) Expansion plug. 2. When determining what type of flow control to use in an emergency, good judgment shall be exercised to avoid entering a gaseous atmosphere whenever practical. Emphasis shall be placed on customer and employee safety when determining flow control. No person shall enter a gaseous atmosphere in a confined space without proper safety equipment including breathing apparatus, and another person outside of the confined space. 6.3 STATIC ELECTRICITY Polyethylene plastic pipe does not readily conduct electricity however a static electric charge can buildup on inside and outside surfaces, and stay on the pipe surface until some grounding device such as a tool or a person comes close enough for the static electricity to discharge to the grounding device. Discharging one part of the pipe surface will not affect other charged areas because static electricity does not flow readily from one area to another. Polyethylene pipe cannot be discharged by attaching normal grounding wires to the pipe. A static electricity discharge to a person, a tool, or a grounded object close to the pipe surface can cause an electric shock or a spark that can ignite a flammable gas or combustible dust atmosphere causing fire or explosion. Precautions against possible ignition from static electricity in a gaseous atmosphere shall be taken prior to performing the work. A. Plastic Pipe: A wetting agent on the surface of the pipe provides a conductive path to rapidly diffuse static electricity. 1. The rags or burlap must remain wet with soapy solution during the entire operation. 2. All pipe in the work area shall be wetted with a soapy water solution* from soil to soil the full length of the excavation. 3. Make sure that contact with the soil is made at the ends. 4. For purging operations of 5' or less, the above method can be utilized for dissipating static electricity. For purging of sections over 5' in length, refer to CS H-5, Purging. When performing any maintenance, splices, repairs, taps, etc. on any existing plastic

Page No: 6 of 7 gas lines, control of static electricity is a major concern. The following is the procedure to be used in static electricity control: 1. Expose pipe by excavating below pipe to working area desired. 2. Clean off exposed plastic pipe then thoroughly rinse off with approved soapy water solution. 3. Wrap pipe with cotton rags or burlap sacks soaked in a conductive anti-static liquid or a dilute soap and water solution. 2. Wrap starting at the trench wall inward along the pipe on both sides of the repair to be made toward the work area providing a path for the static charge to ground. 4. Be certain rags touch the ground with 4-6 slack. Pour soapy water solution over rags, being sure to saturate them and pool soapy water solution on ground where rags contact ground. 5. Install jumper cables on tracing wire to be cut and spliced. 6. Install jumper cables on all metallic tools being used. *Note: A soapy solution can be made by mixing 8-12 ounces of leak test soap with one (1) gallon of water. B. Steel or other Metallic Pipe: The use of ground cables and ground rods or plates shall be utilized as a precaution against static spark. 6.4 SMOKING 1. Before any pipe or tools are installed or removed place ground straps, insulated wire, or other approved device on each tool, pipe, or pipeline facility that is separated or may be separated. Ensure that each surface is clean and that cables make adequate connection. 2. Ground rods or plates shall be securely placed in the ground as to provide an adequate path for the static electricity and as not to be disturbed during the performance of the work. 3. Ground cables shall remain in place throughout the entire work performance. 4. Use of brass tools will reduce the chance of creating an accidental spark. Smoking shall be carefully restricted to safe distances (220 feet or greater) from work areas. Under the following circumstances, no employee shall smoke nor allow anyone else to smoke in the restricted area. 1. When any job is in progress that will allow gas to escape. 2. When doing work in a vault where gas is under pressure.

Page No: 7 of 7 3. When flammables, such as gasoline, diesel fuel or acetone might be present. 4. When "No Smoking" signs are posted, cigarettes, matches and lighters shall be left at a safe distance. Barricades, caution tape, and no smoking signs shall be utilized to define restricted area during the work performance. 6.5 COMBUSTIBLE ATMOSPHERE Before entering areas where gas can accumulate, such as vaults and excavations that have been plated overnight test for the presence of combustible gases will be made with a combustible gas indicator (CGI). Electric tools or fusion equipment may not be explosion-proof and may ignite a flammable gas atmosphere. DO NOT operate electrical devices that are not explosion proof in a flammable gas atmosphere. 6.6 PREVENTING AIR FROM ENTERING OPEN MAINS Whenever possible, a main line shall not be open at two places at the same time, such as a blow-down or a cut in the line. This may permit a draft of air to enter the line at one opening and escape at the other, which allows the possible formation of an explosive mixture. This can be caused by wind pressure or by difference in elevation of the two openings, permitting air to enter the lower of the two openings. This must be guarded against, particularly when working large size mains. No main, service or other gas piping shall be cut apart without being properly grounded and purged by approved method. One method of reducing the risk of air from entering a mainline is to cover the opening with a canvas tarp of other fire resistant material while preparing to make repairs.