EzFlex Combustible Gas Leak Detector Model EZ40



Similar documents
Combustible Gas Leak Detector 720b

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

User Manual. Humidity-Temperature Chart Recorder. Model RH520

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

High Temperature InfraRed Thermometer with Laser Pointer

User's Guide Integrating Sound Level Datalogger Model

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

ExStik TM ph Waterproof Meters

Ground Resistance Clamp-On Tester

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

User's Guide. Integrating Sound Level Datalogger. Model Introduction

COMBUSTIBLE GAS AND HC REFRIGERANT LEAK DETECTOR OPERATING INSTRUCTIONS DETECTS ALL HYDROCARBON & OTHER COMBUSTIBLE GASES JB INDUSTRIES

el-720 Carbon Dioxide Gas Leak Detector User s Guide

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

Mold Alert... Operation Manual P0270

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Hygro-Thermometer + InfraRed Thermometer Model RH101

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

User's Guide. Pinless Moisture Meter. Model MO257

Manual for Fire Suppression & Methane Detection System

RGC-IR Remote Gas Calibrator for IR400

Alarm Clock USER GUIDE

USER GUIDE. LED Light Meter. Model LT45

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

DSM155 Digital LED Light Meter User s Manual DSM155

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

Intelli-Time Alarm Clock model 13027

62 Max/62 Max + Infrared Thermometer

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Dual Laser InfraRed (IR) Thermometer

Owner s Manual & Safety Instructions

Temperature Humidity Meter

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Portable Bluetooth Speaker. Quick Start Guide. Model: BTS201

Automatic Phone-Out Home Monitoring Systems

Instructions A Amp AC/DC Current Probe

Wireless Indoor/ Outdoor Thermometer

CO-220 Carbon Monoxide Meter

Ground Resistance Clamp On Tester

COMPLETE MANUAL. Version: Optic. September 2015 (English), version 1.0. EnergyOT Optic Developed and Manufactured by Genoa Spark, lda Made in Portugal

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model ABOUT THIS ALARM

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

User Guide. 4 wire Earth Resistance Tester Model GRT300

How To Use The Visifault Visual Fault Locator

TWO BURNER PROPANE CAMPING STOVE

Water Leak Detection System

LED Par 56 Short DMX ORDERCODE 42421

Voice Dialer System & Power Monitor VD-5100-SM

3 WATT LED SPOTLIGHT Model No. SLM

PRODUCT WARRANTY. Page 20

Atomic Alarm Clock model 13131W2

Cable Tester Pro ORDERCODE D1909

i410/i1010 AC/DC Current Clamp

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

900 MHz Lightweight Wireless Stereo Headphones

WARNING: This product contains chemicals known to the state of California to cause cancer, or birth defects or other reproductive harm.

Integrating Sound Level Meter and Datalogger

Sip/Puff Switch User Guide

AD-01 Slave Auto Dialer. Owner s Manual

Thermistor Thermometer MODEL NO

Wolverine Data PASS Portable Scanner User Manual V1.0

Instructions & Safety Information Models A220-20D and A220-20L Version 2

How To Use A Cdm250 Digital Multimeter

Owner s Guide. ca6554

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

Microwave Meter. Instruction Manual

User's Guide. Digital Sound Level Meter. Model

POWER GEAR SLIDE OUT MANUAL

AS-801 Promotion-On- Hold Segregator. Version 2.10

INSTRUCTION MANUAL MODEL PCD-88

TWO BURNER PROPANE CAMPING STOVE

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Weather Radio Alarm Clock

12 Volt 30 Amp Digital Solar Charge Controller

Tympanic Thermometer

TECHANGLE November 30, 2005 TECHNICAL PAGE

Bottom Loading Water Dispenser

User Guide. Temperature and Humidity Datalogger. Model 42280

CA-125 Owner's Manual

Transcription:

User's Guide EzFlex Combustible Gas Leak Detector Model EZ40

Introduction Congratulations on your purchase of the Extech EZ40 Combustible Gas Leak Detector. The EZ40 detects the presence of combustible gas and nuisance vapors (Natural Gas, Methane, Ethane, Propane, Butane, Acetone, Alcohol, Ammonia, Steam, Gasoline, Jet Fuel, Hydrogen Sulfide, Smoke, Industrial Solvents, Lacquer Thinner, Naphtha) in concentrations as low as 10% LEL for Methane and alerts the user with audible and visual alarms. The 16 (406mm) flexible gooseneck provides easy access in difficult to reach locations. This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Description 1. Probe clip 2. Sensor tip guard & sensor 3. Alarm light 4. Ready light (Power-on) 5. On/Off slide switch 6. Earphone jack 7. Tick rate (sensitivity) adjustment Note: Battery compartment is on rear of unit 5 6 7 4 3 2 1 2

Operation WARNING! Always turn the meter on in an atmosphere free of combustible gas. Read and understand this manual before using the meter. Do not replace the batteries in an explosive atmosphere. Frequently check meter operation using an unlit gas burner or lighter Warm-up 1. In a gas free atmosphere, slide the ON/OFF switch to the right to power on the detector. 2. Hold the EZ40 in the clean ambient air during its 5 minute (typical) warm-up, self-zero cycle. 3. Some intermittent ticking and warbling alarm tones may be experienced for a short time as the meter warms up. 4. The alarm will slowly decrease and a steady ticking rate will indicate that the EZ40 ready for use. If the meter is in an area where combustible gas is present, the alarm may not decrease. Note: Warm-up time will vary depending on when the last time the meter was used. Zero The EZ40 will automatically zero itself on activation. If the sensor was overexposed, the EZ40 will enter into an automatic cycle to reset. In this instance, the unit will alarm at peak level and decrease to zero. Earphone Jack In an area with high levels of background noise, an earphone can be plugged in to the EZ40. In addition, the speaker is disabled when an earphone is connected so the ticking and alarm will not disturb others in the general area. Caution: Tick and alarm sounds through the earphone are very loud. % LEL, a definition: The LEL of a flammable gas is the minimum concentration of that gas, at normal ambient conditions, at which it will burn if there is a source of ignition present. At a concentration below the LEL, the gas will not burn. Gas detectors for flammable gases are calibrated in the range 0-100% LEL Leak Detection 1. Adjust the sensitivity to establish a slow constant tick rate 2. Trace the sensor around the source of the suspected leak. When leaking gas is detected the tick rate will increase. 3. If the level of gas is approximately at 10% LEL of Methane, the Alarm LED will blink and the warbling tone will increase in pitch with increasing gas concentration. 4. In areas of high gas concentration, the tick rate can be readjusted to pinpoint the location of the leak. 5. Turn the sensitivity dial counterclockwise to reset the tick to a lower rate. 6. The tick will increase as you get closer to the source of the leak. 3

Maintenance Caution! Storing in a damp environment will damage the sensor! Battery Replacement If the green READY LED flashes or does not illuminate, the batteries need to be replaced. The battery compartment is located at the rear of the EZ40. Replace the three C batteries by sliding the battery compartment door and accessing the battery compartment. Ensure that the compartment cover is securely fastened when finished. Cleaning and Storage Wipe the meter only with a damp cloth as needed. Do not apply abrasive, solvents, or other cleaners to the surface of the meter or sensor. Store with the batteries removed and avoid extreme temperature and humidity. Specifications Gases Detected Sensitivity Sensor Alarm Natural Gas, Methane, Ethane, Propane, Butane, Acetone, Alcohol, Ammonia, Gasoline, Jet Fuel, Hydrogen Sulfide, Smoke, Industrial Solvents, Lacquer Thinner, Naphtha, Carbon Monoxide (indication only, not to quantify), 50 ppm methane Solid State Visual and Audible at minimum 10% LEL (40% max) for Methane Warm-up Approx. 5 minute Response Time Less than 2 seconds (up to 40% LEL) Duty Cycle Intermittent Power supply 3 x C 1.5V alkaline batteries Battery life Approx. 8 hours continuous use typical Operating Temperature 32 to 122 o F (0 to 50 o C) Storage Temperature -22 to 140 o F (-30 to 60 o C) Operating Humidity 10 to 90% RH (non condensing) Approvals CE Dimensions 8.7 x 2.83 x 1.8 (221 x 72 x 46mm); gooseneck 16 (40cm) Weight 18.4oz (520g) Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. 4

Support Hotline (781) 890-7440 Tech support: Ext. 200; Email: support@extech.com Repair/Returns: Ext. 210; Email: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright 2006 Extech Instruments Corporation All rights reserved including the right of reproduction in whole or in part in any form. 5