Similar documents
SCADAvantage Network Topology System software products

Natural gas chromatograph LNG gas quality testing

Line sheets system host software Measurement and automation systems. Connect and control with ABB. Introduction. Making sense of software

FloBoss 104 Flow Manager

3500/62 Process Variable Monitor

3DLevelScanner II TECHNICAL DATA SHEET

Technical Data Sheet. 3DLevelScanner

Analog signal converters CC-E I/I Current / current isolators

Microcor Wireless Transmitter (MWT)

For Multi-Parameter Meters see mvx

WEATHER STATION FOR SOLAR FARM MONITORING

4-Channel Thermometer / Datalogger

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

The L&J Engineering Model MCG 1500SFI Servo Gauge

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Rosemount 333 HART Tri-Loop

Gas Turbine Fuel Control Valve

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

COMBIMASS. Technical Data COMBIMASS eco-bio +

WIRELESS INSTRUMENTATION TECHNOLOGY

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

3500/93 System Display

Foxboro Evo Process Automation System

EBS852 (Contrac) Power Electronic Unit

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

3500/40M Proximitor* Monitor

Micro Motion 3098 Gas Specific Gravity Meter

Research RF Sputtering Packages

Unidirectional Transmitter/ Receiver Units Introduction

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Integrating Sound Level Meter and Datalogger

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Fisher FIELDVUE DVC2000 Digital Valve

Rosemount 333 HART Tri-Loop

Technical Information RIA14

Rackmount Intelligent Pressure Scanners

3500/25 Enhanced Keyphasor*Module

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

(AB) TOTALFLOW. XSeries Remote Controller. User's Manual

PRODUCT PROFILE FEATURES

Hand-held thermometer Model CTH7000

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Multi-Range Programmable DC Power Supplies 9115 Series

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

nvision Reference Recorder

Signal Conditioning Amplifier System

Duct Humidity Transmitter

HYDRUS ULTRASONIC METER

4 Posiflow Proportional Solenoid Valves

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

IFC 070 Technical Datasheet

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Fisher D3 Control Valve

Totalflow Web Interface. Installation and Configuration. Proprietary information. Copyright 2014 ABB, All rights reserved.

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

3500/22M Transient Data Interface

ROC Protocol Specifications Manual

Model: DC-A2IO Advanced HVAC Controller

ORION TELECOM NETWORKS INC. T1

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Multi-Range Programmable DC Power Supplies 9115 Series

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

NETWORK ENABLED EQUIPMENT MONITOR

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

SERIES. Series Start-Up Guide

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Micro800 Programmable Controllers. Bulletin 2080 Selection Guide

The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

Centro-Matic Automatic Lubrication Systems System Controls

Waveguide Access Point WGA631. Product Guide

Inductive sensor NI10-M18-Y1X-H1141

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Open channel & partially filled pipe Ultrasonic flow meters

O C M III. Open Channel Flow Monitor

PIEZOMETER AIRFLOW MEASURING RING

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

Electronic Control Devices The European Product Catalogue 2007

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Wireless Gauge and Absolute Pressure Transmitters Series XYR 5000, Model WG5xx/WA5xx Specifications - Americas

SCADAPack 530E 535E. remote Programmable Automation Controller

Sierra S-Series Smart Interface Software User Manual

Transcription:

Data sheet DS/2101113-EN Rev. AD XFC 6201EX flow computer XSeries products Introduction Based on ABB Totalflow XSeries technology, the XFC 6201EX offers an explosion proof product for linear metering and automation systems. The XFC 6201EX is an accurate and reliable linear gas flow computer (turbine, rotary, pd, ultrasonic, etc) with the capability to measure and monitor gas flow in compliance with AGA, API and ISO standards.

XFC 6201EX flow computer XSeries products Standard Cast explosion proof enclosure LCD display (4 X 16) Main electronics board Termination board 2 RS232/485 software selectable comm ports 1 Configuration port (inside rear enclosure or optional external PCCU connection, as shown on page 1) Externally powered from 9 to 30VDC Onboard User IO : 1 AI, 1 DI/PI, 1 DO Access to optional I/O daughter card 512K FLASH (Program Storage) 512K PROM (Flash Loader) 512K RAM (Data Storage) 32K E 2 PROM (software config) Stable time-base (7.5 ppm) Integral multivariable transducer (EXIMV) Optional Twelve (12) I/O point daughter card Manifold EX configuration port assembly 100 ohm platinum RTD Mounting Kit Separate battery backup, power supply package Totalflow consistently provides new and innovative products and systems in support of accurate, reliable and auditable gas measurement. As such, the XFC 6201EX includes features grounded on a thorough understanding of the natural gas industry s custody transfer and measurement needs. 2 DS/2101113-EN XFC 6201EX flow computer

Features Low cost, high reliability design Cast Aluminum enclosure, powder coated Low power consumption LCD 4 16 character display standard Stable time base (accurate integration) Dual level security code data protection Monitors operation limits for detection, and re-porting of abnormal conditions Complies with API 21.1 standard for custody transfer devices 40+ days historical records (user configurable up to 180+ days of hourly and daily data records) Calculation of flow rates, volumes and energy in accordance with AGA 7, AGA 3-85, AGA 3-92, ISO-5167 and AGA-5 Optional support for other primary elements Super compressibility calculations per NX-19 or AGA8-92 Gross or Detail Smart (temperature and pressure compensated) integral, factory calibrated pressure transducer Flow retention during user transducer calibration Selectable 3 or 5 point user calibration of pres-sure sensor 100 ohm platinum RTD Automatic internal calibration of RTD with user programmable offset Software selectable (RS232/RS485/RS422) ports Hazardous Area Classifications: CSA C/US, ATEX and IECExReal time clock (lithium battery powered) Advanced embedded data logger Multi-tube capability Programmable alarm filtering and exception re-porting capabilities Multiple protocol options including Totalflow packet protocol and various Modbus protocols User programmable Modbus registers User programmable math and logic IEC 61131 user programming environment IO expansion via optional daughter card Software control of power to communications equipment XFC 6201EX flow computer DS/2101113-EN 3

FC6200EX XFC 6201EX flow computer XSeries products Hardware modularity Hardware functionality of XSeries devices (including the XFC 6201EX) can be extended in a flexible and simple way by adding optional I/O modules or "Plug-in" cards. The XFC 6201EX is expandable by the addition of a "plug-in" I/O daughter card. The system recognizes the additional I/O automatically and configures the IO Scanner subsystem accordingly. The 6201EX I/O Daughter Card (2102458-001) provides an additional 12 I/O points to the 6201EX. These I/O points are comprised of a fixed combination of Analog and Digital points. The analog point configuration is comprised of three (3) 0-10V (10K ohm impedance) inputs and one (1) 0-20mA output. (The analog output is a "SINK" mode and must be used in conjunction with an external power source) The digital point configuration is comprised of four (4) digital inputs and four (4) digital outputs. The digital inputs also function as event counters and are capable of accepting NAMUR type sensors. The digital outputs are optically-isolated type 1A switches capable of switching 200mA of 48VDC or 40VAC. Div 1 or Zone 1 Non-hazardous area RS-232 or RS-485 & switched power option Communications device 9-30 Vdc power Power supply 4 DS/2101113-EN XFC 6201EX flow computer

Software modularity A keenly flexible and stable real time environment, this software represents significant modularization through use of object oriented design principles. Totalflow supplied objects (applications) can be enabled in our factory or by you, one or more times on the same device. It is this framework that allows the support for multi-tube measurement. Supported Software applications continually grow, but a sample of standard applications include: AGA7 rotary/turbine meter run AGA3 orifice meter run ISO 5167 orifice meter run VCone (precision and wafer) meter run Ultrasonic meter run Realtime Datalogger (trending) Valve Control (Feedback controller) RAMS (Alarming, Exception Reporting) Operators (simple math / logic) IEC 61131 (complex math / logic) Selectable Units (user selectable engineering units) Display Keypad Handler IO subsystem Handler Tank Level Application Therms master application (live analysis input from chromatograph)therms slave application (live analysis input received from Modbus master) Multiple protocols (Totalflow native low power, Modbus slave (RTU/ASCII), Modbus master (RTU/ASCII), LevelMaster, Btu 8000/8001, Enron Modbus, ABB Multivariable Transducer, and others). XFC 6201EX flow computer DS/2101113-EN 5

XFC 6201EX flow computer XSeries products General specifications XFC 6201EX Dimensions Weight Certification Mounting Operating temperature (ambient) EMC requirements Nominal diameter: 6 inches (15.24cm) Nominal length: 8 inches (20.32cm) Nominal: 16.5 pounds (7.48kg) CSA C/US Class 1, Division 1, Groups C, D, T6 Enclosure Type 3R (with breather/drain), Type 4X (without breather/drain) ATEX Zone 1, KEMA 07ATEX2038, II 2G, Ex d IIB, T6; Enclosure IP53 (with breather/drain), IP66 (without breather/drain) IECEx CSA 10.0001, Ex d IIB T6 Ta= -40 C to +60 C (IP53 with breather drain, IP66 without breather drain) Pipe mount -40 to 140 F (-40 to 60 C) EMISSIONS: European Regions: EN55022 Class B Emissions (Radiated) EMISSIONS: North America Regions: CFR 47, Part 15, Subpart B, Class B, FCC Emissions ICES-003 Issue 2, Rev. 1, Class B ITE Emissions AS/NZS CISPR 22-2004 (Australia/New Zealand) IMMUNITY: European Regions: EN 61000-6-1 Immunity: EN61000-4-2:95, ESD, ±8 k V Air, ±4 k V Contact EN61000-4-3:95 RF Immunity, 10 V/m EN61000-4-4:95 EFT, 2 kv EN61000-4-6:95 Conducted Susceptibility, 10Vrms EN61000-4-8:93 Power Frequency Magnetic Field 3A/m Electronics Power Memory Communication ports LCD interface Security switch Time base stability Scan rate AGA3/AGA7/ISO5167/ VCone calculations External DC voltage 9 to 30 VDC Data stored in 512K SRAM. (Lithium battery backup) Application programs stored in 512K Flash. Flash loader stored in 512K PROM Registry and Configuration files stored in 32K E 2 PROM Transducer factory calibration data stored in separate E 2 PROM 1 dedicated PCCU (Local Configuration Port) 2 RS232, RS485 or RS 422 (Software selectable). Dedicated interface for 4 x 16 Liquid Crystal Display (LCD) On/Off dual-level on-board security switch ± 7.5 ppm (parts per million) All inputs sampled at 1Hz rate Calculations are tested and verified to be within ± 50 ppm (parts per million) as stated in API 14.3.4 6 DS/2101113-EN XFC 6201EX flow computer

Integral Multivariable (EXIMV) specifications Multivariable unit Temperature limits Compensated -20 to 140 F (-29 to 60 C) Operational -40 to 185 F (-40 to 85 C) Storage -40 to 185 F (-40 to 85 C) Resolution 16 Bit analog-to-digital conversion (0.003% FS) (0.004% FS effective signal resolution) Vibration performance Less than 0.025 psi per G (2 G maximum) at 1 Hz, decreasing to zero at 1 KHz in straight line mode. Mounting specification AP specifications can be met in any orientation along any plane. Reference conditions Temperature at most recent factory or user calibration: static pressure <100% of URL Static pressure Accuracy (including linearity, hysteresis, & repeatability at reference conditions) Ambient Temperature Effect per 160 F (71 C) Stability (for 12 months) ± 0.075% of user calibrated spans from 20% to 100% of URL ± 0.075% of URL ± 0.06% of reading ± 0.1% of URL Temperature Process range Accuracy (as shipped from factory) Accuracy (after single point field calibration) -80 to +230 F (-62 to 110 C) ± 0.35 F (± 0.2 C) over operating range ± 0.2 F (± 0.12 C) repeatability over operating range Available ranges AP (psia) 100 500 1500 XFC 6201EX flow computer DS/2101113-EN 7

Contact us ABB Inc. Process Automation Toll-free: + 1 800 442 3097 Quotes: totalflow.inquiry@us.abb.com Orders: totalflow.order@us.abb.com Training: totalflow.training@us.abb.com Support: totalflowsupport@us.abb.com Main Office 7051 Industrial Boulevard Bartlesville, OK 74006 Ph: +1 918 338 4888 California Office 4300 Stine Road, Suite 405-407 Bakersfield, CA 93313 Ph: +1 661 833 2030 Texas Offices 3700 West Sam Houston Parkway South, Suite 600 Houston, TX 77042 Ph: +1 713 587 8000 3900 South County Road 1290 Odessa, TX 79765 Ph: +1 432 563 5144 150 Eagle Ford Road Pleasanton, TX 78064 Ph: +1 830 569 8062 www.abb.com/upstream Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2016 ABB Inc. All rights reserved Product webpage DS/2101113-EN Rev. AD 06.2016 Kansas Office 2705 Centennial Boulevard Liberal, KS 67901 Ph: +1 620 626 4350