Fuel Treatment and Conditioning Systems



Similar documents
DNVGL-RU-0050 Edition October 2014

Electrical Shore Connections / Cold Ironing

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

ROLLED STAINLESS STEEL PLATES, SECTIONS AND BARS

Management of Safety and Environmental Protection (SEP)

General Description of The CMC- Services

ST. VINCENT AND THE GRENADINES

Gas Detector System, Portable/Fixed Oxygen Analysis and Gas Detection Equipment

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Cable Trays and Ducts (Metallic)

Technical Bulletin. Oil Record Book entries: Machinery space operations (Part 1) Including January 2011 amendments to Technical Bulletin 24

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

Rules for Classification and Construction Ship Technology

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines

Exhaust Scrubbers. What you need to know. Move Forward with Confidence

Periodically Unattended Machinery Space

Dynamic Positioning Systems

MU Cooling System. Hi-Pres. Low sulphur fuel cooling system. System specifications HI-PRES MARINE & OFFSHORE

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Copyright 2012 Mayekawa Mfg. Co.,Ltd. All Rights Reserved.

CHAPTER PETROLEUM CONTACT WATER

IMO WORK PROGRAMME OF THE COMMITTEE AND SUBSIDIARY BODIES

DNV GL PREPARING FOR LOW SULPHUR OPERATION

TABLE OF CONTENT

Factory owners must ensure the boiler is:

CIMAC Guideline

TYPE APPROVAL CERTIFICATE

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Cooking at the Speed of light!

EMISSIONS FROM MARINE ENGINES VERSUS IMO CERTIFICATION AND REQUIREMENTS OF TIER 3

FLASH TANK ECONOMIZER PRODUCT GUIDE

How To Build An Lng Fuel Tank Container

Marpol 73/78 Annex VI Regulations for the Prevention of Air Pollution from Ships. Technical and Operational implications

GAS FLAWLESS - FORM C

A.1 Obligations and reporting of the gaining Society. Plans to be Submitted by the Owner to the Gaining Society

Refinery Equipment of Texas. Mini - Refinery Feasibility Overview

Tank Heating Solutions. For Oil Spill Response Vessels

Rules for Classification and Construction Additional Rules and Guidelines 3 Machinery Installations

SOx - FUEL CHANGE MANUAL. Manual No. 01

Designed for multi-injector endurance testing, the

Industry Guidance on Compliance with the Sulphur ECA Requirements

CREW MANNING OFFICES, PRIVATE RECRUITMENT AND PLACEMENT SERVICES

DNVGL-CP-0393 Edition December 2015

DNVGL-CP-0209 Edition March 2016

NFPA31FuelOilPiping 1 Revised

Explosion of a gasoline vapour cloud formed in a hydrocarbon loaded effluents storage tank 10 December 1999 Arquata Scrivia Italy

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

ANNEX 17 DRAFT AMENDMENTS TO SOLAS REGULATIONS II-2/4 AND II-2/16. Part B Prevention of fire and explosion

Tanker Officer Training Standards (TOTS) 4B Chemical Tanker Simulator Verification Course

Problems with Hypo: Best Design Practices for Smooth and Efficient Sodium Hypochlorite Feed Systems Chad Hantelman, City of Bremerton Jeff Zahller,

I. STEAM GENERATION, BOILER TYPES

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Uniform Application of MARPOL Annex I, Revised Regulation 12

Jobson THE RIGHT CONTACT

Bunkers Regulatory and Practical Considerations. Piraeus, 8 November 2012 Capt. Simon Rapley

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

WASTE Application Form - Dublin Waste to Energy SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE

DIRECTIVE 055: STORAGE REQUIREMENTS FOR THE UPSTREAM PETROLEUM INDUSTRY. August 2012

Frequently Asked Questions: North American Emission Control Area (ECA) U.S. Coast Guard Office of Commercial Vessel Compliance

CLASSIFICATION NOTES

Link-Up. Solid Fuel Association Guide to Central Heating.

IGEMA BOILER LEVEL & TDS CONTROLS

Flex separation systems, S-separators

How To Reduce Energy Efficiency On Ships

TYPE APPROVAL CERTIFICATE

NORSOK STANDARD H-001 Rev. 4, Nov Heating, ventilation and air-conditioning

The Pipelines Regulations, 2000

Rules for Classification and Construction Additional Rules and Guidelines

ABOVE-GROUND STORAGE TANKS

UPDATE ON MAINE'S UNDERGROUND TANK LAWS

Issues and measures for use of low-sulfur fuel oil

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

THE CORPORATION OF THE CITY OF COURTENAY BYLAW NO A bylaw to amend Storm Sewer Bylaw No. 1402, 1986

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

STANDARD PLUMBING AND DRAINAGE REGULATION 2003

OIL STORAGE REQUIREMENTS OF THE SPCC REGULATIONS. Christopher J. Ecsedy, P.E. Fuss & O'Neill, Inc. 146 Hartford Road Manchester, CT 06040

OIL POLLUTION PREVENTION REGULATIONS

The Worcester Greenstar System Filter. An innovative solution for reducing system contaminants

Waste Oil Collection / Storage

MFP14, MFP14S and MFP14SS Automatic Pumps

Fire Pump Plan Review March 2010

TABLE OF CONTENT

Integrated management systems Ship operating companies

C. starting positive displacement pumps with the discharge valve closed.

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE

Backflush filter R8-30W

Hot water supply, distribution and use

Plumbing for retail food businesses

(a) Purpose. The purpose is to safeguard potable water supplies by preventing backflow into public water systems.

Course available 24/7 for up to six months from the date of purchase or until completion

Fuels Safety Program. Liquid Fuels Handling Code Adoption Document Amendment

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.

77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

OVERSEAS MARINE CERTIFICATION SERVICES (OMCS)

TABLE OF CONTENT

Oily Water Separator SKIT/S-DEB

Transcription:

RULES FOR CLASSIFICATION OF Ships PART 6 CHAPTER 14 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Fuel Treatment and Conditioning Systems JULY 2006 This chapter has been amended since the main revision (July 2006), most recently in July 2011. See Changes on page 3. The content of this service document is the subject of intellectual property rights reserved by Det Norske Veritas AS (DNV). The user accepts that it is prohibited by anyone else but DNV and/or its licensees to offer and/or perform classification, certification and/or verification services, including the issuance of certificates and/or declarations of conformity, wholly or partly, on the basis of and/or pursuant to this document whether free of charge or chargeable, without DNV's prior written consent. DNV is not responsible for the consequences arising from any use of this document by others.

FOREWORD DET NORSKE VERITAS (DNV) is an autonomous and independent foundation with the objectives of safeguarding life, property and the environment, at sea and onshore. DNV undertakes classification, certification, and other verification and consultancy services relating to quality of ships, offshore units and installations, and onshore industries worldwide, and carries out research in relation to these functions. The Rules lay down technical and procedural requirements related to obtaining and retaining a Class Certificate. It is used as a contractual document and includes both requirements and acceptance criteria. The electronic pdf version of this document found through http://www.dnv.com is the officially binding version Det Norske Veritas AS July 2006 Any comments may be sent by e-mail to rules@dnv.com For subscription orders or information about subscription terms, please use distribution@dnv.com Computer Typesetting (Adobe Frame Maker) by Det Norske Veritas If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million. In this provision "Det Norske Veritas" shall mean the Foundation Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas.

Rules for Ships, July 2006 Pt.6 Ch.14 Changes Page 3 CHANGES General The present edition of the rules includes additions and amendments approved by the Board as of June 2006 and supersedes the January 2003 edition of the same chapter. The rule changes come into force as indicated below. Text affected by the main rule changes is highlighted in red colour in the electronic pdf version. However, where the changes involve a whole chapter, section or sub-section, only the title may be in red colour. This chapter is valid until superseded by a revised chapter. Amendments July 2011 General The restricted use legal clause found in Pt.1 Ch.1 Sec.5 has been added also on the front page. In addition, the layout has been changed to one column in order to improve electronic readability. Main changes coming into force 1 July 2006 General Minor adjustments to the rule text have been done, modifying the text in accordance with new knowledge, and practical arrangements. The consequences of these rule changes for DNV customers are assumed small, yet it is intended that the modifications now proposed will make the rules more suitable - for both owners and building yards alike. Sec.1 General Requirements Item C101 has been amended with respect to plans and particulars that shall be submitted for approval. Item D201 has been amended with respect to requirements for the fuel operation manual. Sec.2 System Arrangements and Components Requirements for transfer lines with respect to means for draining/ sampling and venting have been deleted. In item C206 a guidance note has been added to clarify the interpretation of requirements to drainage from fuel oil service tanks. Sec.3 Instrumentation and Automation The sub-section on requirements for measuring equipment for testing of fuel properties has been deleted. Sec.4 Testing and Survey In item A102 a guidance note has been added to clarify the requirements for sea trials. Corrections and Clarifications In addition to the above stated rule requirements, a number of corrections and clarifications have been made in the existing rule text.

Rules for Ships, July 2006 Amended July 2011, see page 3 Pt.6 Ch.14 Contents Page 4 CONTENTS Sec. 1 General Requirements... 5 A. Fuel Treatment System... 5 A 100 Application... 5 A 200 Class notation... 5 A 300 Environmental conditions... 5 B. Definitions... 5 B 100 Terms... 5 C. Documentation... 5 C 100 Plans and particulars... 5 D. General Requirements... 6 D 100 System design principles... 6 D 200 Fuel operation manual... 6 Sec. 2 System Arrangements and Components... 7 A. System for Storage and Transfer of Fuel... 7 A 100 Bunker manifolds... 7 A 200 Fuel storage tanks... 7 A 300 Fuel transfer system... 7 B. Fuel Oil Settling and Daily Service Tanks... 7 B 100 Tank arrangement... 7 B 200 Settling tanks... 7 B 300 Daily service tanks... 7 C. Fuel Treatment System... 8 C 100 General... 8 C 200 Centrifugal separators... 8 C 300 Fuel heaters and viscosity control equipment... 8 Sec. 3 Instrumentation and Automation... 10 A. General... 10 A 100 Extent of instrumentation... 10 Sec. 4 Testing and Survey... 11 A. General... 11 A 100 General... 11

Amended July 2011, see page 3 Rules for Ships, July 2006 Pt.6 Ch.14 Sec.1 Page 5 SECTION 1 GENERAL REQUIREMENTS A. Fuel Treatment System A 100 Application 101 The rules in this chapter apply to systems and equipment for treatment of residual fuel for use in diesel engines. A 200 Class notation 201 Vessels with fuel system and equipment complying with the relevant rules may be given the additional class notation FUEL (- cst, - kg/m 3, - C) The numbers in brackets indicate the maximum viscosity in cst at 50 C, the maximum density in kg/m 3 at 15 C of the fuel oil and the minimum outside air temperature for which the installations are approved. A 300 Environmental conditions 301 For determining heating capacity the following minimum temperatures apply: Sea: 0 C Outside air temperature: 0 C, if a lower temperature is not defined in the class notation. B. Definitions B 100 Terms 101 Fuel as used in this context is an organic liquid hydrocarbon oil derived from petroleum refining. This does not preclude the incorporation of small amounts of additives intended to improve some aspects of performance. 102 Fuel quality is determined with reference to values of parameters describing chemical and physical properties. It is assumed that fuels containing contamination in excess of that specified in ISO 8217/latest version/ Grade RMH55 are not bunkered. 103 Fuel storage system incorporates tanks for fuel storage which are not intended to influence the cleaning process (settling and drainage of contaminants). 104 Transfer system incorporate the system of pipes, valves, filters and pumps intended for the transfer of fuel between storage tanks and from storage tanks to the treatment system 105 Treatment system incorporates the system of tanks, pipes, valves heaters, filters, pumps, separators and other permanently installed components intended for cleaning and conditioning of the fuel. It also comprises arrangements for chemical treatment of the fuel by the use of fuel additives. 106 Booster system is the pressurised system of pumps, heaters, valves, filters and other equipment permanently installed to provide the transfer of fuel from the day tank to the engine high pressure fuel pumps. 107 Separator is a permanently fitted centrifuge for fuel cleaning. 108 Fuel additives are chemical substances used to improve the fuel treatment efficiency and or fuel performance in diesel engines as well as minimising harmful effects. C. Documentation C 100 Plans and particulars 101 Additional to the documentation required by other relevant rules, the following plans and particulars shall be submitted for approval: drawing and specification of transfer pipes with heat tracing (including any low sulphur fuel change over system for SO x Emission Control area -SECA) arrangement of heating coils in fuel tank arrangement of fuel pre-treatment monitoring and alarm system heat balance calculations comprising heated fuel tanks, fuel pre-heaters and heat losses, throughout the system

Rules for Ships, July 2006 Amended July 2011, see page 3 Pt.6 Ch.14 Sec.1 Page 6 test programme for onboard trial, including log of temperatures, viscosity, alarms, etc. fuel operation manual including bunkering procedures, including change over procedures and time needed for change over to low sulphur fuel oil before entering SO x Emission Control areas procedures for fuel oil samples handling and records in connection with MARPOL Annex VI. D. General Requirements D 100 System design principles 101 The fuel treatment plant shall be designed and installed in accordance with relevant parts of the rules unless otherwise stated in this chapter. 102 The fuel system shall ensure that: the content of undesired impurities is reduced to a level safe for diesel engine use. the fuel is delivered to the engine with the correct viscosity and pressure throughout the full operating range of engine power. the system provides redundancy as required in relevant rules. two different bunker batches may be stored and handled without need for mixing. D 200 Fuel operation manual 201 A manual describing systems, equipment and guidance for bunkering, handling of fuel and operation of systems shall be provided. The fuel operation manual shall emphasize measures and procedures in order to minimize the mixing of old and or new or incompatible fuel oils during bunkering and change over operations.

Amended July 2011, see page 3 Rules for Ships, July 2006 Pt.6 Ch.14 Sec.2 Page 7 SECTION 2 SYSTEM ARRANGEMENTS AND COMPONENTS A. System for Storage and Transfer of Fuel A 100 Bunker manifolds 101 An adequate bunker manifold shall be provided on each side equipped with spill tray with a volume of at least 160 litre capacity to prevent oil pollution during bunkering operations. 102 An approved arrangement for sampling of fuel shall be provided at each of the bunker manifolds or in the fuel bunkering line. A 200 Fuel storage tanks 201 At least two storage tanks shall be provided. If only two tanks are installed, the smallest tank shall not to be less than one third of the total tank capacity. 202 Arrangement enabling representative fuel sampling shall be provided. 203 All tanks shall be provided with sufficient heating capacity to keep the bulk temperature of the oil on at least 45 C. 204 Isolating valves for heating coils in each tank to be provided. Sampling cocks in condensate return lines to be provided. 205 The storage tanks shall be provided with monitoring equipment for temperature and level. A 300 Fuel transfer system 301 The transfer pumps should be located as low as possible. 302 As far as practical, long suction lines shall be avoided. 303 Transfer lines shall be provided with heat tracing and insulation. B. Fuel Oil Settling and Daily Service Tanks B 100 Tank arrangement 101 At least two settling and two daily service tanks shall be provided. 102 Settling and daily service tanks shall not be located adjacent to the ship's side. Guidance note: Minimum distance between hull and tank bulkhead to be 760 mm for inspection access. ---e-n-d---of---g-u-i-d-a-n-c-e---n-o-t-e--- B 200 Settling tanks 201 The usable capacity of each settling tank to be sufficient for 24 hours operation at maximum fuel consumption. 202 Heating capacity, sufficient to increase the temperature of the oil from 45 C to at least 70 C within 12 hours, shall be provided. 203 The tanks shall be provided with suitable openings for access and ventilation to allow effective tank cleaning. 204 The tank bottom to be so designed that precipitated material may be drained to the sludge tank by opening an easily accessible drain valve. Tank bottom to be sloped towards the drain outlet. 205 Suction outlets for separators shall be placed above bottom to avoid precipitated material to escape. Minimum distance from the bottom to the suction shall be 500 mm. 206 For sludge removal by use of separator, a bottom suction is required. B 300 Daily service tanks 301 The usable capacity of each daily service tank to be sufficient for 12 hours operation at maximum fuel consumption.

Rules for Ships, July 2006 Amended July 2011, see page 3 Pt.6 Ch.14 Sec.2 Page 8 302 Heating capacity, sufficient to increase the temperature of the oil from 70 C to at least 90 C within 6 hours, shall be provided. 303 The tanks shall be provided with suitable openings for access and ventilation to allow effective tank cleaning 304 The tank bottom to be constructed with smooth bottom and with slope towards the drain outlet. 305 The suction to the booster system shall be placed minimum 500 mm above bottom to avoid precipitated material to escape. 306 The arrangement of the tanks and interconnected piping has to be such that unintentional ingress of fuel from one tank to another is avoided. 307 Overflow pipe to run from the bottom of the service tank to the top of the settling tank (above the overflow discharge from the settling tank). C. Fuel Treatment System C 100 General 101 The fuel treatment system shall at least consist of: centrifugal separators fuel heaters automatic filters booster system including pressurised mixing tank automatic viscosity control equipment automatic temperature control. C 200 Centrifugal separators 201 Separators shall be type approved according to the Type Approval Programme for Fuel Oil Separators ensuring sufficient cleaning. 202 The capacity of separators, their number and configuration shall be such that with any unit out of operation, the system shall maintain an adequate performance at the maximum fuel consumption. Guidance note: Capacity of separators will be considered equal to Certified Flow Rate (for the viscosity class in question) as determined by the Type Approval Programme for Fuel Oil Separators. ---e-n-d---of---g-u-i-d-a-n-c-e---n-o-t-e--- 203 Heaters, control systems, pumps and other auxiliary equipment for the cleaning process shall be so designed that the fuel is kept at the condition necessary for the separators to function as required. 204 Fuel feed rate to separators to be controlled by means of rpm (frequency) of feed pump. (Or other equal means to control flow rate approved by the Society in each case). 205 Fuel heaters for separators to have automatic temperature control. Controller to have proportional and integral function (PI-controller). Possibility for manual control to be arranged. 206 For steam heating arrangements condensate drain from heaters to be controlled by float operated drain traps (or other equal means approved by the Society in each case). Drain traps discharge shall be by gravity. Guidance note: If the pressure of the heating medium inside the heater is sufficient to displace the condensate to the condensate tank located at a higher level, this is considered equivalent to gravity drain. ---e-n-d---of---g-u-i-d-a-n-c-e---n-o-t-e--- 207 The discharge pipe to the sludge tank shall be made as short and vertical as possible. The pipe diameter shall not be less than the separator sludge outlet stud. 208 Centrifugal separators are preferably to be positioned on top of the sludge tank. 209 A fixed arrangement for sampling fuel before and after the separator(s) shall be provided. C 300 Fuel heaters and viscosity control equipment 301 The system of fuel heaters shall be designed with built in redundancy. 302 With anyone heater out of service, the remaining heaters shall have the capacity of raising the fuel

Amended July 2011, see page 3 Rules for Ships, July 2006 Pt.6 Ch.14 Sec.2 Page 9 temperature sufficiently to achieve a viscosity required for the correct injection of fuel into the diesel engine at a flow rate corresponding to 120% of the maximum fuel consumption. 303 Heaters to be designed with a maximum surface temperature of the heating elements of 170 C for steam and 200 C for thermal oil heating systems. Guidance note: 170 C surface temperature normally corresponds to a heat load of 10 kw/m 2. ---e-n-d---of---g-u-i-d-a-n-c-e---n-o-t-e--- 304 Fuel heaters in the booster system shall be provided with control equipment maintaining the desired viscosity. 305 The viscosity controller shall have proportional and integral action (PI controller). 306 Means for manual temperature control of the heaters are required. 307 For steam heating arrangements condensate drains from heaters to be controlled by float operated drain traps (or other equal means approved by the Society in each case). Drain trap discharge shall be by gravity.

Rules for Ships, July 2006 Amended July 2011, see page 3 Pt.6 Ch.14 Sec.3 Page 10 SECTION 3 INSTRUMENTATION AND AUTOMATION A. General A 100 Extent of instrumentation 101 Alarms, indications and automatic controls as required for the class notation E0 (unattended machinery spaces), as far as applicable for the fuel system, shall be provided. 102 In addition to 101 the monitoring functions given in Table A1 are required. Table A1 Monitoring functions Parameter Viscosity at engine inlet Temperature in settling and service tanks Pressure differential areas - fuel filters Level in mixing tank Alarm High /Low High/Low High Low

Amended July 2011, see page 3 Rules for Ships, July 2006 Pt.6 Ch.14 Sec.4 Page 11 SECTION 4 TESTING AND SURVEY A. General A 100 General 101 The complete installation is subject to testing in the presence of a surveyor. 102 When all work concerning adjustment and starting of various units of the plant has been completed, sea trials shall be carried out. The sea trials shall include at least 4 hours continuous operation in stabilised condition and on a fuel grade close to the grade for which the system is designed. For systems designed for IF 700, fuel with lesser viscosity may be accepted, but not less than IF 380. Guidance note: The 4 hours continuous operation may be carried out concurrently with the endurance test as required by Pt.4 Ch.3 Sec.1 I300. ---e-n-d---of---g-u-i-d-a-n-c-e---n-o-t-e--- 103 The builders shall prepare and submit for approval a detailed test programme The test programme shall be kept onboard, all filled in and signed by the surveyor. 104 The instruction and routines prescribed for fuel oil treatment shall be surveyed.