MICROPACK Visual Flame Detection Application Note



Similar documents
How to Select a Flame Detector

THE DETECTION OF GREENHOUSE GASES

Ultrasonic Gas Leak Detection

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

Fire & Gas Detection; Reducing Risks in Rail Loading/Unloading Facilities. By Todd Spicer Technical Specialist Spartan Controls Fire & Security

Flame detection across the spectrum. Range Brochure

Application Requirement

Fire and Gas Solutions. Improving Safety and Business Performance

Safe Offloading from Floating LNG Platforms (SAFE OFFLOAD) R. V. Ahilan Noble Denton Europe

Communication Links for Offshore Platforms. A User s Guide to Troposcatter Communications

Eni experience and research with IR video-camera imaging

Master Class. Electrical and Instrumentation (E &I) Engineering for Oil and Gas Facilities

Methane to Markets Oil and Natural Gas Technology Transfer Workshop

The photoionization detector (PID) utilizes ultraviolet

27558_Xtralis_MultiSiteBrochureREV_Eng_210x297_v1_a4 bro 04/05/ :24 Page 1 Multi-site security

Improving SCADA Operations Using Wireless Instrumentation

FACILITY SAFETY SIGNAGE GUIDE: 10 SIGNS TO SPOT DURING A PLANT WALKTHROUGH

Galaxy Flex SECURITY THAT FITS WITH YOUR BUSINESS AND LIFESTYLE. Protect your property

Distributed Temperature Sensing - DTS

OFFSHORE OIL & GAS SECTOR STRATEGY 2014 TO 2017

DANISH ENERGY AGENCY S GUIDELINES ON SAFETY- AND HEALTH RELATED CONDITIONS ON OFFSHORE INSTALLATIIONS, ETC. HEALTH & SAFETY CASES

YOUR PARTNER FOR THERMAL IMAGING SECURITY APPLICATIONS

Darchem Thermal Protection

System 800xA Fully automated ESD System for major gas plant increases safety

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Reducing CO2 emissions for Offshore oil and gas Operations under ETS. Margaret Christie, Environmental Advisor, UK Business Unit, Premier Oil UK Ltd

TECHNICAL INFORMATION

STATE-OF-THE-ART FLAME, SMOKE AND INTRUSION VIDEO DETECTION TECHNOLOGY FIRE DETECTION AND VIDEO SURVEILLANCE

Axis IP surveillance. Endless possibilities for video surveillance.

Taking a Giant Leap in Subsea Technology

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

COLORADO APCD IR Camera Survey Program Guidance/Protocol (rev. 11/8/11)

GAS AND FLAME DETECTION

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Triple Waveband Infra-Red Flame Detection

Electric heat tracing

Wireless Remote Video Monitoring

RIVA Megapixel cameras with integrated 3D Video Analytics - The next generation

Michael A. Mitchell, Cameron Flow Control, DYNATORQUE Product Manager

False Alarm/Unwanted Fire Signals Reduction Guidance

Wireless Remote Video Monitoring

export compressor instability detection using system 1* and proficy** smartsignal software

UOP Gas Processing. Realizing the Value of Your Natural Gas and Synthesis Gas Resources

Continuous flow direct water heating for potable hot water

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Transformer Deluge Systems

TABLE OF CONTENT

sierra monitor corporation Fire and Gas Detection Systems

A concise guide to Safety Glasses, the different standards and the effects of light on the eye. Contents. Links. Year of publication: 2010

SOFTWARE-IMPLEMENTED SAFETY LOGIC Angela E. Summers, Ph.D., P.E., President, SIS-TECH Solutions, LP

Select the Right Relief Valve - Part 1 Saeid Rahimi

Satellite REPRINTED FROM. John D. Prentice, Stratos Global Corp., USA,

Early Fire Detection & Condition Monitoring

LNG SAFETY MYTHS and LEGENDS

Overview. Components of an alarm system Technology behind the equipment Communication Platforms Industry Terminology False Alarm Tips DSC products

Module 5. Fire and Emergency Alarm System Part I- Basics

Fire. The Fire Installers Mate. A guide to fire alarm systems design

AFS Center. Data Center Info. Arizona Facility Services 2331 West Alameda Dr Tempe, AZ (602) Main (602) Fax

Smile Security and Surveillance Pvt. Ltd. (SSSPL) Brings to you

Hydrogen Detection in Oil Refineries

POROUS BURNER - A New Approach to Infrared

Gas Standards and Safety. Guidance Note GAS INSTALLATIONS SUPPLIED FROM BIOGAS FACILITIES - ACCEPTANCE REQUIREMENTS GAS ACT 2000

Real-time Video Monitoring Increases the Efficiency of SCADA Process Management

Safety Integrity Level (SIL) Studies Germanischer Lloyd Service/Product Description

Fire detection in kitchens

Video Architectures Eyes on the Future: The Benefits of Wireless Technology for Fixed Video Surveillance

Totally Wireless Video Security

Integrated Fire and Gas Solution - Improves Plant Safety and Business Performance

Secure Ports Solutions

N4385A / N4386A Distributed Temperature System (DTS)

Fisher FIELDVUE Instrumentation Improving Safety Instrumented System Reliability

ATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES

Preview of Period 3: Electromagnetic Waves Radiant Energy II

Air Eliminators and Combination Air Eliminators Strainers

Building Integration System Your platform for customized security and safety management

OPAL TM Detector range

Mineral rights ownership what is it and why is it so unique in the USA?

Building Integration System Your platform for customized security and safety management

CHAPTER 3 AVI TRAVEL TIME DATA COLLECTION

TOXIC AND FLAMMABLE GAS CLOUD DETECTORS LAYOUT OPTIMIZATION USING CFD

Experion Integrated Fire & Gas Safety and Security Monitoring at your fingertips! Ajay Varghese

Introduction to Fourier Transform Infrared Spectrometry

This is a licensed product of Ken Research and should not be copied

Sam Docknevich, PSP, Security Service Portfolio Manager. Are You Prepared? The impending impact of Code on Servicing Security Systems

Permanent Reservoir Monitoring (PRM) System Installation: The Installers Perspective

SPECIAL APPLICATIONS

The infrared camera NEC Thermo tracer TH7102WL (1) (IR

Cisco Integrated Video Surveillance Solution: Expand the Capabilities and Value of Physical Security Investments

Dielectric Withstand Testing in a Production Environment

A Review of Security System for Smart Home Applications

Birth of a Norwegian. giant

Gas Detection for Refining. HA University

Sieger Searchpoint Optima Plus

QUALITY SERVICES LEADING TO QUALITY BUSINESS

THE GAS UTILITIES S AND THE JAPAN GAS ASSOCIATION S EFFORTS TO IMPROVE SAFETY

Establishing of the expansive gas supply chain that combines upstream, midstream and downstream operations

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Transcription:

MICROPACK Visual Flame Detection Application Note ABSTRACT Optical flame detection has evolved over the last 30 years with improved sensors, processing power, and high electronics reliability, which has greatly improved the acceptance and use of automatic optical fire detection in the harshest of environments and applications. Single wavelength ultraviolet (UV) detectors were originally used for the protection of large integrated oil and gas production platforms in the North Sea, followed by single wavelength infrared (IR) detectors, but problems with false alarms from numerous natural and artificial sources both on the platforms and from adjacent installations prompted the oil industry to search for a better technology. This paper covers the recurring problem of flare reflections on offshore platforms and how the evolving technology of visual flame detection has solved this problem. BACKGROUND The origins of visual flame detection came from developments in the North Sea offshore oil and gas industry in the mid 1990 s. The UK oil sector started to look at the use of floating oil and gas production facilities, to develop oil reserves in deeper water than conventional fixed platforms could be cost effectively deployed. These floating facilities called FPSO s (floating production storage and offloading) created a wealth of different challenges from conventional fixed platforms, including challenges to conventional infrared flame detectors. Due to the relative close proximity of the process relief flare to the top side exposed production modules, reflected radiation could adversely affect the operation of the flame detection system. It should be noted that these process relief flares can be up to 1,000 times the size of the industry standard test fire used to specify flame detector range. As there are multiple highly reflective surfaces on the facilities, including piping, vessels and skids, reflections from the process flare could be multi directional and not easy to identify or isolate. The use of shields or hoods to partially limit the field of view of the conventional flame detectors was a compromise that some oil companies were reluctant to undertake but had no choice. In practice, the use of shields or hoods was later proven to be ineffective. In 1997, a major oil company that had done extensive testing of optical flame detectors since the initial development of the first major oil field in the North Sea in the early 1970 s was in the preliminary design phase of its first FPSO to develop an oil field in the North Atlantic Ocean, West of the Shetland Islands (see Figure 1). Company managers were aware of the challenge from the process relief flare being in such close proximity to the top side production facilities and contacted a specialized fire detection consulting company to help work on a new type of flame detection system that would ignore reflections from the flare, whilst still providing fire detection coverage in these areas.

Visual Flame Detec on The consultant had been testing various brands Figure 1. The original FPSO where visual flame detection was first used. of flame detectors as a consultant to the North Sea oil industry and had developed a specialized and unbiased understanding of the strengths and weaknesses of optical flame sensors. Some of this testing combined with research into the use of charged coupled device (CCD) image sensors for flame detection brought about the development of the first visual flame detection system for this first North Sea FPSO. THE TECHNOLOGY Visual flame detectors employ a video imaging technique using standard CCD sensors that are used in closed circuit television cameras, combined with advanced algorithms. These algorithms process the live video image from the CCD array and interpret flame characteristics. As most of the original development of visual imaging based flame detection was carried out to ignore the reflections from the process flare, fire sensitivity was not the major objective. IR based flame detectors had better response times and could see fires at greater distances, but it was soon discovered that by not using the IR wavelength associated with most flame detectors, imaging based detectors were not affected by water absorption from rain or from CO2 emissions from gas turbine exhaust and other sources. Due to their spatial dependency, visual flame detectors would not adjust their sensitivity depending on what was in the field of view of the detector. Figure 2. Large scale LNG fire testing Other applications for flame detectors in the late 1980 s like the protection of commercial and military aircraft hangars dictated that automatic flame detectors respond to fires at distances of 150-200 feet. This became the de facto industry specification. As these detectors were then applied to the offshore oil industry, it was not readily apparent that, due to the very confined and condensed nature of the oil and gas processing areas, distances from a detector location to the actual fire source rarely exceeded 15-20 feet, so the 200 feet potential range and sensitivity of these conventional flame detectors was not only unnecessary, but probably led to an increase in the false alarms from flare reflections. So even though the first generation visual flame detector had less than 50 percent of the sensitivity, compared to conventional type flame detectors, it did not matter in the close confines of an offshore platform. Nevertheless, a major weakness of visual based flame detection is that it cannot detect invisible type fires such as hydrogen or very weak flames such as pure methanol and pure sulphur. Brightness associated with most hydrocarbons fires is one of the fundamental parameters of how the technology works. Combined with the live video output of the visual flame detector, operators in remote parts of the plant have the benefit of confirming the hazard and can take a

Visual Flame Detec on more informed and safer course of action to combat the fire when detected with a visual flame detector. Some manufacturers of conventional multi -spectrum IR and combination UV/ IR detectors have recently introduce models with a bolt-on surveillance camera to achieve the same verification capability. Naturally, the fundamental issue of false alarms from flare reflections is not resolved with this combination flame detector and camera. the detector s field of view, visual imaging can respond to the presence of intruders in an area. Oil and gas companies have made good use of this feature by deploying visual flame detectors in remote unmanned platforms targeted by pirates. CURRENT DEVELOPMENTS Since the introduction of the first generation of visual flame detection, the visual flame devices are now into their third generation. With the introduction of colour images for real time surveillance, the facility operator now gets a human eye view of the area being covered. The newer sensor has a larger array, thus providing more pixels for detection, offering over twice the sensitivity of the original mono only visual flame detector. Due to the aforementioned issue with multi spectrum IR flame detectors being affected by hot CO2 from exhausts of turbine driven compressors and generators, the current generation visual flame detection can indeed surpass the sensitivity of multi spectrum IR as there is no need to reduce the sensitivity depending on what is in the detectors field of view. A micro memory card has been added on board the electronics module to provide pre and post fire incident recording. With the wide variety of product offerings in the security industry, it is now much easier to interface the video surveillance image with video IP encoders and digital video recorders as opposed to having proprietary hardware and HMI software. With the use of IP encoders the video from the flame detectors can now be reviewed remotely, practically from anywhere in the world. Some companies are using the video output from the surveillance sensor to provide intrusion monitoring of the areas being protected. Again, standard off the shelf surveillance equipment now incorporates motion detection algorithms. Hence, provided viewing zones are set up within Figure 3. Operators are provided with instantaneous and vital visual confirmation of the hazard FLAME DETECTION PERFORMANCE TESTING STANDARDS The national fire code relating to automatic fire detection NFPA72 now recognizes video based detection for both flame and smoke detection and a number of companies are introducing video based smoke detection devices for the protection of large spaces such as stadiums, convention centres, and warehouses. The main challenge to the acceptance of video based smoke detection is the lack of approval standards for this method of detection. Because visual imaging flame detection was originally developed to reduce false alarms from reflected flare radiation, it was never designed to be the sole flame detection technique. As there are traditional types of optical flame detectors offered in the marketplace, approval standards like FM 3260, the current ANSI standard for radiant energy flame detectors, are more forgiving when the standardized tests are performed on conventional flame detectors. As more manufacturers enter the fray with imaging

VISUAL FLAME DETECTION flame detection, the standards are likely to change to accommodate the different way imaging fire detectors detect fires. One particular challenge with standards testing is associated with the very nature of fires. Since fires change constantly, it is often difficult to represent their erratic behaviour with standard fires. For example, a Bunsen burner methane flame in the laboratory is precise and controlled. Consequently, testing flame detectors to this type of flame may not necessarily yield results that correlate well with device performance in the field. After all, flame detectors are designed to detect uncontrolled fires in hazardous processing environments. THE IMPORTANCE OF DETECTION SYSTEM COVERAGE DESIGN It is also important to have a defined fire target size for any given risk or application and then the flame detection system can be designed accordingly. A few of the major oil companies have defined fire size targets, depending on the level of risk associated with the process. All too often a designer will take the maximum detection distance as stated on the flame detection manufacturers data sheet and apply this specification across the facility without taking into consideration the variety of sources from the process that can limit the sensitivity of typical flame detectors. There are software mapping tools available today that take into consideration the shadowing effect the process plant has on detector coverage, allowing designers to maximize the coverage using a minimum number of detectors. These tools also produce drawings, indicating the design criteria for the detection system and the way in which the design was achieved showing detector positions and their coverage. Many operators in the oil industry use this study as part of their safety case for the regulatory authorities. Figure 4 shows a typical computer model of fire dispersal at a plant. Figure 4. Typical flame detection assessment from software mapping tool.

VISUAL FLAME DETECTION LESSONS LEARNED As the flare reflection issue has become more widely understood by the oil and gas industry, a number of FPSO s, offshore platforms, and onshore plants have specified visual flame detection either as the only flame detection technology or in combination with conventional flame detectors, where the visual flame detector is located in areas most prone to reflections from the flare. A number of facilities both onshore and offshore have had to replace their existing flame detectors with visual flame devices due to the high frequency of false alarms. In the case of a Norwegian North Sea FPSO, which was recently started up, the reflections from the process flare tripped dozens of flame detectors, initiating an emergency shutdown (ESD), when the vessel was offloading oil to a shuttle tanker. Another case involving a major scale onshore gas processing and export facility has a large ground flare. During a particular process upset, the flare tripped several triple-ir flame detectors, some of which were located up to half a kilometre away from the flare. As the detectors in various parts of the plant activated simultaneously, again an automatic ESD was initiated, disrupting the transfer of oil from the offshore platforms to an onshore plant. In another instance, surge tanks feeding a large export pipeline were also affected by false alarms. As major production losses estimated to exceed $100 million were incurred by the oil company, the decision was made to replace all of their detectors on the site with visual flame detectors. To date no false alarms have been reported from the visual flame detection system. THE FUTURE Although visual flame detection is not a panacea and is not suitable for every type of hazard, the benefits of imaging technology are being recognized by more of the major oil companies around the world. Combined with improvements in performance, visual flame detectors will become more sensitive to smaller fires at much greater distances with quicker speed. The future Figure 6: Visual flame detector with process relief flare in background. looks bright for intelligent imaging based fire detection. REFERENCES BP GP30-85 Fire and Gas Detection Group Practice National Fire Protection Association NFPA 72 2006 Edition This article was written by Adrian Lloyd of MICROPACK Americas., part of the Micropack (Engineering) Group Ltd. Email: AdrianLloyd@micropackamericas.com Figure 5. A typical application for visual flame detection, on an offshore oil and gas production