Use Case Task 1-7: Network Equavalents between EMS & Planning



Similar documents
Generation Interconnection Feasibility Study Report-Web Version. PJM Generation Interconnection Request Queue Position Z1-055

Realization of control center HMIs by using IEC and CIM data bases for communication and data handling

AMI Use Case: B3 - Utility detects tampering or theft at customer site 03/16/06

Outage Notification. "Acknowledgment: This material is based upon work supported by the Department of Energy under Award Number DE-OE

Use Case 29: Data Acquisition from External DMS Network Monitoring Subsystem

Running a Load Flow Analysis

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

Applying Use Cases to Microcontroller Code Development. Chris Gilbert Cypress Semiconductor

Use Case Diagram. Tom Polanski, Analex Corporation CSCI Object-Oriented Analysis and Design (Spring 2001) Homework #3 Use Cases

RHODE ISLAND. Electronic Business Transactions (EBT) Standards. for Electronic Data Interchange (EDI) in a Restructured Electric Industry

Energy Management Systems (EMS)

S7 for Windows S7-300/400

Load Dispatcher (Class Code 5223) Task List

FRCC Coordination Procedure. Title: FRCC Reliability Coordinator Contingency Analysis Monitoring Criteria

SCADA and Monitoring for Solar Energy Plant

Business Requirements for Measure for Billing

Modeling a Problem Scenario with UML

From Business Event to BUC

SOP-RTMKTS Test and Approve Operations Software Applications. Contents

ADMS(Advanced Distribution Management System ) in Smart Grid

Midwest Reliability Organization Procedure For NERC PRC-012

Generation and Transmission Interconnection Process

Generator Interconnection and Deliverability Study Methodology Technical Paper

SIMONE Capacity Tools and Gas Transport Commercial Management System Integration

Managing Relion IEDs Protection and control IED manager PCM600

Wide Area Monitoring Current Continental Europe TSOs Applications Overview

4.1.1 Generator Owner Transmission Owner that owns synchronous condenser(s)

RSA Authentication Manager 7.1 to 8.1 Migration Guide: Upgrading RSA SecurID Appliance 3.0 On Existing Hardware

Informix Dynamic Server May Availability Solutions with Informix Dynamic Server 11

Alberta Reliability Standard Cyber Security Configuration Change Management and Vulnerability Assessments CIP-010-AB-1

Computer Network and Communication

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

OpenScape Voice V8 Application Developers Manual. Programming Guide A31003-H8080-R

Capacity Plan. Template. Version X.x October 11, 2012

Design Document Version 0.0

Software Requirements Specification

System Protection Schemes in Eastern Denmark

Evolution of Control for the Smart Transmission Grid

SCADA. The Heart of an Energy Management System. Presented by: Doug Van Slyke SCADA Specialist

PCI-SIG ENGINEERING CHANGE REQUEST

References Appendices I. INTRODUCTION... 6 A. Background... 6 B. Standards... 6

Time functions. Functions of the relay. instabus EIB Application program description. September A1 Binary 510D01

Intel Desktop Board D925XECV2 Specification Update

Nicholas Mezei CSCI 6448 OOA&D Homework #3: Use Cases. Use Case Diagram: Home Security System. Alarm System

3/20/2009 Inventory Management System DTCC

White Paper. Convergence of Information and Operation Technologies (IT & OT) to Build a Successful Smart Grid

YZP : SAUTER Vision Center

San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions June 4, Electric Grid Operations

ZXUN USPP. Configuration Management Description. Universal Subscriber Profile Platform. Version: V

Logix5000 Controllers Import/Export Project Components

ABB Network Manager in Endesa s Energy Management Center

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE

Data Exchange and Protocol Process Flows for Electric Deregulation in The State of New Jersey

Documentation. M-Bus 130-mbx

Reclamation Manual Directives and Standards

Complete fleet management package for Qualitrol Information Products

User Manual WatchPower

PSS SINCAL efficient planning software for electricity and pipe networks. Siemens PTI Software Solutions. Answers for energy.

Future Stars. Grade X Manual Chapter 1 Networking and Telecommunication. telecommunication. Telephones, telegrams, radios and televisions help

Creating a Usable Power Supply from a Solar Panel

San Diego Gas & Electric Company FERC Order 717 Transmission Function Employee Job Descriptions August 10, Electric Grid Operations

Best Practices for Creating Your Smart Grid Network Model. By John Dirkman, P.E.

WORKING IN TEAMS WITH CASECOMPLETE AND MICROSOFT VISUAL SOURCE SAFE. Contents

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

Capacitor Voltage Transformer. Answers for energy.

INTELLIGENT DISTRIBUTION NETWORK ANALYSIS AND INFORMATION ARCHITECTURE DESIGN

The BPM to UML activity diagram transformation using XSLT

PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY

IEC SCL - MORE THAN INTEROPERABLE DATA EXCHANGE BETWEEN ENGINEERING TOOLS

US Environmental Protection Agency Office of Pesticide Programs

Grid of the Future. Integration of Renewables Energy Storage Smart Grid. Presentation by David Hawkins Lead Renewables Power Engineer Grid Operations

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES

[MS-SPACSOM]: Intellectual Property Rights Notice for Open Specifications Documentation

FINAL CONFERENCE 10 TH JUNE 2015

Role of CIM for Power System Model Exchange - ISO/RTO Exchanges with TOs

UML TUTORIALS THE USE CASE MODEL

Electric Field Operations Organization

MANAGEMENT INFORMATION SYSTEMS 8/E

Application/Connection Examples

Federal Wage System Job Grading Standards for Electric Power Controlling, Table of Contents

Alberta Reliability Standard Cyber Security Security Management Controls CIP-003-AB-5

SolovatSoft. Load and Performance Test Plan Sample. Title: [include project s release name] Version: Date: SolovatSoft Page 1 of 13

Large Scale Systems Design G52LSS

Transcription:

Use Case Task 1-2: Transport Contingency Specifications Page 1 Use Case Task 1-7: Equavalents between EMS & 1 Summary: Export Equavalents from the EMS or another application for use by the application(s). This would allow correct conversion between the s by operations and transmission as well as generation. 2 Actor(s): Describe the primary and secondary actors involved in the use case. This might include all the people (their job), systems, databases, organizations, and devices involved in or affected by the role performed (e.g. operators, system administrators, customer, end users, service personnel, executives, meter, real-time database, ISO, power system). Actors listed for this use case should be copied from the global actors list to ensure consistency across all use cases. Actor Name Actor Type Role description for this use case (person, system, device, etc.) Person Develop a base to examine an operations event or to establish a new base case for future. EMS Operator Person Attends the EMS and is familiar with its capabilities to export network s EMS System System System for monitoring/controlling the real-time system and includes a bus-breaker network operations for real-time network calculations and includes switches/breakers in the (bus-breaker ). Includes a State Estimator and usually a load flow solution package. External System System System or database that contains on how to handle equivalents and network extents between EMS and, mapping of equipment ID if they are different in EMS and. As well, it will store external network if EMS case needs to be extended to a larger geographic territory. Software System Software for detailed study of network performance, usually representing a larger geographical territory than the network in the EMS. Generally based on a bus-branch (no switches/breakers). software includes power flow, short-circuit, dynamics, etc. CIM XML Method A protocol defined by a NERC profile that establishes the content, naming, relationships, etc. of network data and the file format for a file exchange from one EMS to another such that sufficient data is exchanged to perform a similar load flow solution on the receiving EMS system Model Converter & Topology Processor Base Case Analysis from which network alternatives are studied A software analysis to remove switches/breakers from an operations (bus-breaker ) to a (busbranch ). Uses the switch positions (open/closed) in the operations to connect/disconnect equipment terminals together in the. Load equivalents and network extension with a reference to a dictionary (the external system). The bus-breaker can be developed from base EMS data or from an actual operations mode. A data set that represents the network at a specific point in time either as a past point in time or a significant point in time in the future (e.g. 2008 Summer heavy case). The builds alternatives on this case for transmission expansion scenarios or what-ifs if the case is a case representing a historical operating point.

Use Case Task 1-2: Transport Contingency Specifications Page 2 3 Assumptions / Design Considerations: Equavalents and Extension is based the understanding that the EMS and are different in the following aspects: the may contain details down to the 13.8 kv network, but the EMS rolls the lower voltages up to a 69 kv bus, using an equivalent load at the 69 kv level to represent the lower voltages; a generator plant may be represented in the EMS as a single equivalent machine but in as multiple individual machines; vice versa where equivalences a machine but the EMS represents them in detail; generally after topology processing in an EMS, only connected elements are preserved in the CIM XML or export; it is important to transport data for equipment that may be out of service therefore, the CIM will need a spot to flag in and out of service for each element; EMS may break 3-winding transformer into 3 2-winding transformers; Naming and equipment IDs can be different in EMS and ; 4 Pre-conditions: There must be a concensus on what the actual network is supposed to be, and whether the equavalents make sense. 5 Normal Sequence: Use Case Step Event/ Input to this step Actor activity and tools Description Of Processing Producer Output to be Exchanged Notes or Comments # Event that triggers this step and/or inputs Name of actor(s), activity description, and tools/ applications Describe the processing that takes place in this step. Actors/tools for producing. Actors for receiving Description of produced in this step to be exchanged with 1 Request from for an EMS notifies target EMS system of the need for an EMS. specifies what is being and/or whether contains normal load or real time load. EMS system A file The file is a CIM XML file File consists of a network with a particular timestamp, as specified by engineer 2 CIM XML file - Data converter Extends network using load equivalents, convert busbreaker to the bus-branch. Manually by the or automatic using a software application related to a topology A suitable for use in the target

Use Case Task 1-2: Transport Contingency Specifications Page 3 Use Case Step Event/ Input to this step Actor activity and tools Description Of Processing Producer Output to be Exchanged Notes or Comments # Event that triggers this step and/or inputs Name of actor(s), activity description, and tools/ applications Describe the processing that takes place in this step. Actors/tools for producing. Actors for receiving Description of produced in this step to be exchanged with processor 3 An EMS matching the Open EMS in the application Application Study of EMS and/or use EMS mode as starting point for future base case. Process Complete 6 Exceptions / Alternate Sequences: Describe any alternative actions that may be required that deviate from the normal course of activities. Should the alternate sequence require detailed descriptions, consider creating a new Use Case. None 7 Post Conditions Describe conditions that must exist at the conclusion of the use case. 8 Activity Diagrams Typically an activity diagram with swim lanes for each participating system or actor to graphically describe the step-by-step interactions between actors/systems and the messages exchanged between them. Additionally, sequence diagrams may be developed to help describe complex event flows. 9 References: Use Cases referenced by this use case, or other documentation that clarifies the requirements or activities described. Also any prior work (intellectual property of companies or individuals) in the preparation of this use case. 10 Issues: List of outstanding issues that must be addressed to complete the use case.

Use Case Task 1-2: Transport Contingency Specifications Page 4 ID Description Status 1 A set of rules required in the network equivalency Not started 11 Revision History: No Date Author Description 0 01/29/07 J Y Li Initial version

Use Case Task 1-2: Transport Contingency Specifications Page 5 12 Use Case Diagram