powerful. Intuitive. Customizable. The new star of benchtop flow cytometry



Similar documents
HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE

Boundary-breaking acoustic focusing cytometry

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

FlowSight. Flow cytometry with vision

CyFlow Space Your flexible flow cytometer

CyAn : 11 Parameter Desktop Flow Cytometer

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

Introduction to flow cytometry

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

Easy to use. Compact. Flexible. Sorting Chip

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

NovoCyte Flow Cytometer Operator s Guide

Cytell Cell Imaging System

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Immunophenotyping peripheral blood cells

BD FACSComp Software Tutorial

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

Introduction to Flow Cytometry

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

Introduction to Flow Cytometry

COMPENSATION MIT Flow Cytometry Core Facility

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

APPLICATION INFORMATION

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Flow cytometry basics fluidics, optics, electronics...

How to operate the BD FACSCanto flow cytometer

Attune NxT Acoustic Focusing Cytometer

FACSCanto RUO Special Order QUICK REFERENCE GUIDE

These particles have something in common

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Science is hard. Flow cytometry should be easy.

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

TROUBLESHOOTING FLOW CHART

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

LSR II Users Guide Stanford Shared FACS Facility 06/10/13

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Standardization, Calibration and Quality Control

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Cell Cycle Tutorial. Contents

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

UCHC Guide to CellQuest Pro. FACS Calibur instruments

Zecotek S Light Projection Network Marketing

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

Institut für Experimentelle Immunologie und Bildgebung

Introduction to Flow Cytometry:

Agilent Cary 60 UV-Vis

INSIDE THE BLACK BOX

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Let the BD FACSAria II accompany your best performance ever

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

flow cytometry reinvented

BD FACSVerse. Simply brilliant

Attune Acoustic Focusing Cytometer

Cell Sorting. S3e Cell Sorter

Becton-Dickinson FACSCalibur Flow Cytometer Instructions

FACS Laboratory. BD LSRs Operator Training. Training Guide.

EDF Extended Depth of Field

UV-Vis spectrophotometers

Standard Operating Procedure

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Three Rules for Compensation Controls

Welcome to the fully integrated autoimmune laboratory. Saves time by reducing hands-on functions NOVA Lite Barcoded IFA Slides

Establishing Optimum Baseline PMT Gains to Maximize Resolution on BD Biosciences Digital Flow Cytometers

Flow Cytometry. flow cytometer DNA apoptosis ph

GC-xt. The most flexible GC /GC-MS liquid sample injector

Measurement & Analytics Measurement made easy

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

guava Flow Cytometry easycyte Systems

Cell Sorting. S3e Cell Sorter Quick Guide

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Analyzer Experiment setup guide for LSRII and Canto s

Uses of Flow Cytometry

CyAn ADP with Summit Software User Guide

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

BD FC Beads 8-Color Kit for BD OneFlow Assays

UCHC Guide to FACS DiVa. LSR II instruments

ArC Amine Reactive Compensation Bead Kit

Principles of Flowcytometry

BD FACSAria Flow Cytometer. The first high-speed sorter with a fixed-alignment cuvette flow cell from BD Biosciences

Amino Acid Analyzer L-8900

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

Partec PAS. Your Flow Cytometer.

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

FACSCalibur System User s Guide


Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Transcription:

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

About ACEA Established in 2002, ACEA Biosciences, Inc. develops cutting-edge cell analysis platforms for life science research. More than 1,000 ACEA cell analysis instruments are being used by scientists around the world for a wide range of biological research and drug discovery applications. ACEA released their real-time, label-free xcelligence System in 2008, and continues to develop new technology. To help ensure success of our customers and their applications, ACEA provides exceptional customer service and expert technical support. NOVOCYTE THE NEW STAR OF BENCHTOP FLOW CYTOMETRY Address the full range of current and future multi-parameter cellular analysis research needs with the NovoCyte flow cytometer. ACEA brings researchers high performance flow cytometry at a low investment cost with the NovoCyte platform. ACEA offers a system which is: Powerful - up to 15 parameter detections with enhanced sensitivity and resolution. Intuitive - automated instrument maintenance functions and advanced data analysis capabilities for greater usability. Customizable - 1 to 3 laser options, exchangeable filters, multiple sampling options and flexible analysis formats. HIGH PERFORMANCE LOW COST

KEY INSTRUMENT FEATURES Optimized PMT Voltage & 24 Bit Detection Dynamic Range Provides 10 7 dynamic range for signal detection and processing, offering a broader signal range than other flow cytometers. Wide range of fluorescent and scattering signal intensities eliminates the need for complicated and laborious PMT voltage adjustment. Data acquisition is just load-and-go. Configurable Fluorescence Detection Channels for Enhanced Assay Flexibility Customizable selection and upgrade with lasers of different wavelengths allow for personalized, versatile choices of fluorochromes for flow cytometry assays. User interchangeable filters and dichroic mirrors broaden available fluorescence channels to expand users detection options. 13 Fluorescent Channel Detection: Multiple Laser Options Providing Flexibility of Choice (405nm, 488nm, 640nm) Customize the instrument to meet detection needs with blue, red and violet laser options. System can be upgraded as analytical requirements increase no need to purchase another instrument. State-of-the-art solid-state lasers provide high quality and extremely stable optical illumination. Volumetric Fluidics System for Increased Accuracy & Easy Maintenance Direct absolute counting, no need for addition of counting beads. Real-time monitoring of fluidics prevents flow path obstruction. Accurate pressure sensors monitor fluidic status in real-time, thus the possibility of flow path obstruction is greatly reduced, allowing for reliable and accurate data acquisition. Automated SIP (sample injection probe) washing following sample acquisition minimizes sample carryover and increases capability to detect rare events. High speed data acquisition of 20,000 events per second. Novel Optical Design & Enhanced Signal Detection Patent pending independent beam shaping optics and light collection system maximizes signal detection efficiency, increasing sensitivity and resolution for each fluorescence channel. Fixed optical alignment removes need for daily maintenance and adjustment of optical system, providing convenient operation and superior long-term stability. Optimized forward scatter obscuration bar increases sensitivity. Enhanced small particle detection and resolution as a result of optimized obscuration bar design. 1 2

Key Software Features Pre & Post Acquisition Compensation Experiment Analysis Design Experiment Manager provides a schematic view of the sample analysis being performed. This allows for access to cytometer setting, compensation matrix, report generation, and data analysis. Multiple samples can be analyzed with the same settings by a simple drag-and-drop template function. Instantaneous compensation results can be simply achieved by adjustment of the compensation scaling bar on the plot, allowing rapid and accurate compensation, thus eliminating tedious trial and error adjustments of compensation matrix coefficients. Before Quick Compensation Scaling Bar After Quick Compensation Quick Compensation Plots Automated & Versatile Data Analysis Functions Powerful NovoExpress software allows efficient data acquisition, data analysis and report generation. NovoExpress software provides flexible analysis templates and plotting tools, offering enhanced data analysis efficiency. Rapid Import & Export of Data Files FCS (Flow Cytometry Standard) 3.0 files can be imported for analysis by NovoExpress. Data can also be exported as a FCS 3.0 file for further analysis in a 3rd party software, or as a CSV (Comma Separated Value) file for analysis in programs such as Microsoft Excel. The NovoCyte's volumetric precision pump enables direct absolute counting without the need for reference counting beads. One click enables the concentration of your sample to be calculated. 3 4

Novocyte Provides Outstanding Performance High Sensitivity & High Resolution Detection Highly efficient light collection ensures reliable detection of sub-micron particles and dim signals. Using innovative optical design for light collection and high quality PMTs, fluorescence signals are efficiently detected with exceptionally high signal-to-noise ratio, ensuring a high detection sensitivity for weak positive samples and small particles. Powerful signal detection and data analysis capabilities, and a user friendly software interface guarantee fast, economic, and accurate flow cytometry data generation and reliable data analysis. Immunophenotyping Immunophenotyping quickly identifies candidate cell types, sub-classes and functions. The ACEA NovoCyte flow cytometer can be used for multi-parameter lymphocyte sub-population counting and phenotyping, helper T lymphocyte differentiation and functional study, new sub-population identification, disease specific sub-population identification, and cell surface marker detection. Bangs Laboratories NIST Traceable Particle Size Standards High Fluorescent Signal Resolution Improves Detection Accuracy Advanced optical and fluidic system design, premier quality components, and innovative signal processing algorithms collectively ensure accurate extraction of detection parameters with consistently low variation. Lymphocyte sub-population analysis: Accurate results were quickly obtained for cytotoxic T cells (CD3+CD8+), T helper cells (CD3+CD4+), and natural killer cells (CD3-CD16+56+). Spherotech 8-peak Rainbow Beads Volume-Based Direct Absolute Counting, No Additional Counting Beads Required With a high accuracy syringe pump controlling the injected sample volume and minimal cell loss in the fluidics, the NovoCyte flow cytometer achieves accurate direct cell counting without the need for expensive counting beads. Cell Cycle Analysis Normal human somatic cells are diploids containing a constant amount of DNA. During cell cycle progression, DNA synthesis results in a doubling of total DNA content, followed by restoration of the normal DNA content after mitosis. With the NovoCyte flow cytometer, detailed cell cycle analysis can be performed to understand tumor cell differentiation, cell transformation and cell-compound interaction. A549 cell cycle analysis with PI: After treatment with 10 μm MG132 or 500μM 5-FU for 16 hours, A549 cells were analyzed for cell cycle distribution with the ACEA Novocyte flow cytometer. With the NovoExpress built-in cell cycle analysis module, the plot shows cells in G0/G1 phase (green), S phase (yellow), and G2/M phase (blue). Compared to normal untreated cells, MG132 treated cells were arrested at G2/M phase, while 5-FU treated cells were arrested at G0/G1 phase. 5 6

Levey-Jennings 报 告 操 作 者 :User1 报 告 日 期 : 17:33:07 QC 测 试 微 球 批 号 :FC3MV002 软 件 版 本 :1.0.0.1307 仪 器 序 列 号 :451131110197 Improved Ease Of Use CV 2.00% 1.60% 1.20% 0.80% FSC-H CV MFI 400,000 320,000 240,000 160,000 FSC-H MFI Convenience of Operation & Maintenance With accurate pressure sensors monitoring fluidic status in real-time, the possibility of flow path obstruction is greatly reduced, allowing for reliable and accurate data acquisition. Automated cleaning and de-contamination functionality simplifies routine maintenance. A simple click of a button initiates the automated cleaning and de-contamination process and effectively removes any residual samples in the fluidics path, saving users valuable time from laborious manual cleaning and decontamination routines. Automated instrument QC test provides information on dayto-day performance of the NovoCyte. QC analysis only takes a couple of minutes to run, providing user reassurance. Autosampler Option for High-Throughput Analysis of Multiple Samples Modular autosampler is compatible with sample tubes (24 tubes) and 24/96 well plates, allowing for versatile loading modes and increased throughput. 0.40% The Levey-Jennings Plots Allow Display of Daily Cytometer QC Results Over Time CV 0.00% 2014-2-16 1.60% 240,000 1.20% 180,000 Supporting Your Research CV 2.00% 1.60% 1.20% 0.80% 0.40% 0.00% 2014-2-16 2.00% 0.80% 0.40% Technical Support 0.00% 2014-2-16 2014-2-18 2014-2-22 2014-2-26 2014-3-2 2014-2-18 2014-2-22 2014-2-26 2014-3-2 Our highly skilled technical support team is available to answer questions related to the NovoCyte instrument and software as well as to help address your challenging cellular analysis needs. If your question requires more in depth support we can schedule a visit from our highly trained flow cytometry field applications scientist. One Year Warranty 2014-2-18 2014-2-18 2014-2-20 2014-2-20 2014-2-20 2014-2-22 2014-2-22 BL1-H CV BL2-H CV 2014-2-26 2014-2-26 2014-3-2 2014-3-2 Our standard one-year warranty covers the replacement of any components that may be damaged or faulty through normal recommended use of the NovoCyte instrument. Following receipt of your NovoCyte instrument, our qualified trained representative will provide instrument installation. The instrument performance will be checked to affirm that the instrument is within standard operating specifications. In the event of defects occurring during the warranty period, the instrument will be repaired to manufacturer's standard at an ACEA certified repair site. ACEA will cover the cost of repair including parts, labor and shipment costs. Extended Service Warranty for Total Reassurance ACEA offers extended service warranty options to ensure that any instrument fault has minimal impact to your work, limiting down time and loss of productivity. MFI MFI 80,000 0 2014-2-16 2014-2-20 1,000,000 800,000 600,000 400,000 200,000 2014-2-18 2014-2-18 2014-2-22 2014-2-22 BL1-H MFI 2014-2-26 2014-2-26 0 2014-2-16 2014-2-20 300,000 120,000 60,000 0 2014-2-16 2014-2-20 BL2-H MFI 2014-3-2 2014-3-2 1 ACEA will fully back the performance of the instrument for the duration of the warranty, giving you total peace of mind allowing you to focus on your work. Discuss with an ACEA representative to understand more about how the Extended Service Warranty will enhance your NovoCyte experience. 7 8

NovoCyte Warranty Overview NovoCyte SPECIFICATIONS Coverage One Year Manufacturer Warranty One Year Extended Service Warranty Two Year Extended Service Warranty Model Number 1000 2000 2060 3000 Instrument Installation Shipment Costs (Repair Related) Manufacturer Certified Replacement Parts Maintenance Kit (Cat# 320200090) Software Upgrades Instrument Installation Following Repair EXAMPLES OF COMPATIBLE FLUORESCENT LABELS FL Channel Pacific Blue TM Brilliant Violet TM 421 DAPI 405nm AmCyan Pacific Orange TM Qdot 605 Qdot 655 Qdot 800 Fluorescein FITC Alexa Fluor 488 GFP PI 488nm 445/45 530/30 585/40 615/24 675/30 780/60 * Contact ACEA or your local distributor for complete compatibility list PE PE-Cy TM 5 PE-Alexa Fluor 610 PE-Texas Red PerCP 7-AAD PE-Cy TM 7 APC 640nm Alexa Fluor 647 APC-Cy TM 7 Alexa Fluor 700 Detectors Optics Fluidics Data Processing Sampling Operating Conditions Specification 488 nm 488 nm 640 nm 488 nm 640 nm 405 nm 488 nm 640 nm 445/45 nm 530/30 nm 585/40 nm 615/24 nm 675/30 nm 780/60 nm Laser Configuration Spatially separated beams with 10 x 80 μm elliptical spots Optical Alignment Procedure Fixed, no operator alignment required Flow Cell 170 x 290 μm rectangular quartz flow cell FSC/SSC Resolution FSC: 0.5 μm; SSC: 0.2 μm Cell Size 0.2-50 μm Fluorescence Threshold Sensitivity FITC < 75 MESF; PE < 50 MESF Fluorescence Resolution < 3% CV for CEN Filters User Exchangeable Sample Acquisition Rate 20,000 events/second Volumetric Absolute Count Precision < 5% Sample Flow Rate 5-120 μl/min Sheath Flow Rate 6.5 ml/min Sample Aspiration Volume 10-100 μl Fluid Container Capacity 3 L sheath, 3 L waste, 500 ml cleaning, 500 ml decontamination Carryover < 0.1% Fluidics Maintenance Automated startup, cleaning, decontamination and shutdown Parameters Height and Area for FSC, SSC and all Fluorescent Channels, Width and Time Dynamic Range 24 bit; 7.2 decades logarithmic scale; no need for PMT voltage adjustment Compensation Full inter-beam matrix, during or post acquisition Output Data Files FCS 3.0; CSV; Batch Reports Workstation Dell OptiPlex 7010/7020 SFF with 23" LCD Monitor Computer Operating System Microsoft Windows 7 Professional (64 bit) Software ACEA NovoExpress Manual Sample Loading 12 X 75mm tube Automatic Sample Loading Optional - compatible with 12 x 75mm tube, 1.5 & 2mL tubes, 24-well and 96-well microtiter plates Instrument Dimension (W X D X H) 23.6 x 17.7 x 15.4 in (60 x 45 x 39 cm) Instrument Weight 86 lb (39 kg) Power Requirements 100/115/230 VAC, 50-60 Hz Environment Requirements Temperature: 15-32 C ; Relative Humidity: 80% maximum 9 10

Ordering information Instrument Inspired to advance Your Discovery Laser Configuration Description Catalog Number Blue Laser (488 nm) 3 color, FSC, SSC, Workstation & NovoExpress Software 00 320 100 010 Impedance-based real-time, label-free system since 2008 Blue / Red Laser (488/640 nm) 4 color, FSC, SSC, Workstation & NovoExpress Software 00 320 100 020 Blue / Red Laser (488/640 nm) 6 color, FSC, SSC, Workstation & NovoExpress Software 00 320 100 040 Blue / Red / Violet Laser (488/640/405 nm) 13 color, FSC, SSC, Workstation & NovoExpress Software 00 320 100 110 Accessories Description Catalog Number RTCA SP RTCA DP RTCA MP RTCA HT RTCA Cardio RTCA icelligence Autosampler 00 320 200 010 One year supply of fluidics spare parts 00 320 200 090 ACEA NovoFlow Sheath Fluid (1X; 20L) 871B601 ACEA NovoFlow Sheath Fluid (10X; 5L) 872B601 ACEA NovoClean Solution (1X; 5L) 871B602 ACEA NovoRinse Solution (1X; 5L) 871B603 Extended Warranties - Service Complete Plans Description Catalog Number 1 Year Extended Service Warranty 00 320 400 010 2 Year Extended Service Warranty 00 320 400 020 cutting-edge cell analysis platforms for life science research 11 12

Corporate Headquarters ACEA Biosciences Inc. 6779 Mesa Ridge Road Ste 100 San Diego, CA 92121 t 858.724.0927 f 858.724.0928 toll-free 866.308.2232 www.aceabio.com For life science research only. Not for use in diagnostic procedures. 2014 ACEA Biosciences, Inc. All rights reserved. NovoCyte, NovoExpress, NovoFlow, NovoClean, NovoRinse, xcelligence, and ACEA Biosciences are trademarks of ACEA Biosciences, Inc. in the US and other countries. All other product names and trademarks are the property of their respective owners.