Thermal Analysis of Steam Ejector Using CFD



Similar documents
CFD Analysis of Supersonic Exhaust Diffuser System for Higher Altitude Simulation

A comparison of heterogenous and homogenous models of two-phase transonic compressible

Effect of Pressure Ratio on Film Cooling of Turbine Aerofoil Using CFD

Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

Numerical Investigation of Heat Transfer Characteristics in A Square Duct with Internal RIBS

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

Keywords: Heat transfer enhancement; staggered arrangement; Triangular Prism, Reynolds Number. 1. Introduction

ME6130 An introduction to CFD 1-1

Lecture 6 - Boundary Conditions. Applied Computational Fluid Dynamics

CHAPTER 4 CFD ANALYSIS OF THE MIXER

3. Prescribe boundary conditions at all boundary Zones:

INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

CFD Analysis of Swept and Leaned Transonic Compressor Rotor

Turbulence Modeling in CFD Simulation of Intake Manifold for a 4 Cylinder Engine

Ravi Kumar Singh*, K. B. Sahu**, Thakur Debasis Mishra***

CO MPa (abs) 20 C

CFD Analysis of Application of Phase Change Material in Automotive Climate Control Systems

HEAT TRANSFER ENHANCEMENT AND FRICTION FACTOR ANALYSIS IN TUBE USING CONICAL SPRING INSERT

MAXIMISING THE HEAT TRANSFER THROUGH FINS USING CFD AS A TOOL

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Customer Training Material. Lecture 2. Introduction to. Methodology ANSYS FLUENT. ANSYS, Inc. Proprietary 2010 ANSYS, Inc. All rights reserved.

A Comparison of Analytical and Finite Element Solutions for Laminar Flow Conditions Near Gaussian Constrictions

CFD Analysis of a butterfly valve in a compressible fluid

Waste Heat Recovery through Air Conditioning System

Effect of design parameters on temperature rise of windings of dry type electrical transformer

Theoretical and Numerical Analysis of Heat Transfer in Pipeline System

Modelling and CFD Analysis of Single Stage IP Steam Turbine

EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT TWIST RATIO OF TWISTED TAPE INSERTS

COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE

Dr.A.K.Shaik Dawood. N.V.Kamalesh. Department of Mechanical Engineering, Associate Professor, Karpagam University, Coimbatore , India.

Use of OpenFoam in a CFD analysis of a finger type slug catcher. Dynaflow Conference 2011 January , Rotterdam, the Netherlands

Performance prediction of a centrifugal pump working in direct and reverse mode using Computational Fluid Dynamics

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 4000 OPEN CHANNEL MIXER R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

High Speed Aerodynamics Prof. K. P. Sinhamahapatra Department of Aerospace Engineering Indian Institute of Technology, Kharagpur

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

GEOMETRIC, THERMODYNAMIC AND CFD ANALYSES OF A REAL SCROLL EXPANDER FOR MICRO ORC APPLICATIONS

Optimization of Supersonic Ejector by Condensing Rocket Plume

Experimental Study On Heat Transfer Enhancement In A Circular Tube Fitted With U -Cut And V -Cut Twisted Tape Insert

Flow Physics Analysis of Three-Bucket Helical Savonius Rotor at Twist Angle Using CFD

Heat Transfer Enhancement in a Heat Exchanger using Punched and V-cut Twisted Tape Inserts

Increasing the evaporation temperature with the help of an internal heat exchanger

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

Flow in data racks. 1 Aim/Motivation. 3 Data rack modification. 2 Current state. EPJ Web of Conferences 67, (2014)

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

CFD ANALYSES OF FLUID FLOW AND HEAT TRANSFER IN PATTERNED ROLL-BONDED ALUMINIUM PLATE RADIATORS

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Numerical Simulation of Thermal Stratification in Cold Legs by Using OpenFOAM

International journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

CFD Analysis of a Centrifugal Pump with Supercritical Carbon Dioxide as a Working Fluid

NUMERICAL ANALYSIS OF AERO-SPIKE NOZZLE FOR SPIKE LENGTH OPTIMIZATION

MODELING OF CAVITATION FLOW ON NACA 0015 HYDROFOIL

DESIGN AND FLOW VELOCITY SIMULATION OF DIFFUSER AUGMENTED WIND TURBINE USING CFD

THE CFD SIMULATION OF THE FLOW AROUND THE AIRCRAFT USING OPENFOAM AND ANSA

HYBRID ROCKET TECHNOLOGY IN THE FRAME OF THE ITALIAN HYPROB PROGRAM

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

CFD Analysis Of Multi-Phase Flow And Its Measurements

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

AN EFFECT OF GRID QUALITY ON THE RESULTS OF NUMERICAL SIMULATIONS OF THE FLUID FLOW FIELD IN AN AGITATED VESSEL

NUMERICAL ANALYSIS OF WELLS TURBINE FOR WAVE POWER CONVERSION

Science Insights: An International Journal

Introduction to CFD Analysis

CFD ANALAYSIS OF FLOW THROUGH A CONICAL EXHAUST DIFFUSER

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

AERODYNAMIC ANALYSIS OF BLADE 1.5 KW OF DUAL ROTOR HORIZONTAL AXIS WIND TURBINE

Pushing the limits. Turbine simulation for next-generation turbochargers

Analytical Study of Vapour Compression Refrigeration System Using Diffuser and Subcooling

HEAVY OIL FLOW MEASUREMENT CHALLENGES

Routinely surveying tower overhead vacuum systems can

Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics

Impacts of Perforated Tile Open Areas on Airflow Uniformity and Air Management Performance in a Modular Data Center

Performance Comparison of a Vertical Axis Wind Turbine using Commercial and Open Source Computational Fluid Dynamics based Codes

Keywords: CFD, heat turbomachinery, Compound Lean Nozzle, Controlled Flow Nozzle, efficiency.

Nozzle Vent: A Simpler Approach to Laptop Cooling

PRESSURE DROP ANALYSIS OF INLET PIPE WITH REDUCER AND WITHOUT REDUCER USING CFD ANALYSIS

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Energy Efficient Data Center Design. Can Ozcan Ozen Engineering Emre Türköz Ozen Engineering

NUMERICAL INVESTIGATION OF HEAT AND MASS TRANSFER IN A REFRIGERATED TRUCK COMPARTMENT

EXPERIMENTAL STUDIES ON PRESSURE DROP IN A SINUSOIDAL PLATE HEAT EXCHANGER: EFFECT OF CORRUGATION ANGLE

Comparative Analysis of Gas Turbine Blades with and without Turbulators

O.F.Wind Wind Site Assessment Simulation in complex terrain based on OpenFOAM. Darmstadt,

CFD ANALYSIS OF RAE 2822 SUPERCRITICAL AIRFOIL AT TRANSONIC MACH SPEEDS

Cold Cavity Flow with a

Desuperheater Online Program Sizing Guidance

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

ME 239: Rocket Propulsion. Over- and Under-expanded Nozzles and Nozzle Configurations. J. M. Meyers, PhD

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

Energy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements

AIR STREAMS IN BUILDING FOR BROILERS

Transcription:

Thermal Analysis of Steam Ejector Using CFD T.Aravind 1, Dr P Ravinder Reddy 2, S S Baserkoed 3 P.G. Student, Department of Mechanical Engineering, P.Indra Reddy Memorial Engineering College, Chevella, Ranga Reddy (Dist), Telangana State, India 1 Professor &Head, Department of Mechanical Engineering, Chaitanya Bharathi Institute of Technology, Gandipet, Hyderabad, Telangana State, India 2 Professor &Head, Department of Mechanical Engineering, P.Indra Reddy Memorial Engineering College, Chevella, Ranga Reddy (Dist),Telangana State, India 3 ABSTRACT: This work focuses on the numerical simulation of the working of a steam ejector in order improve the performance. Computational Fluid Dynamics (CFD) was employed for the numerical simulation. In this work the effect of operating conditions on the performance of the steam ejector operating in conjunction with an ejector refrigeration cycle was considered along with the effect of geometry parameter. The model and meshing is done with GAMBIT and FLUENT solver is used for the analysis. The simulations are performed with different operating conditions and geometries. The entrainment ratio is found to increase with the decrease of boiler saturation temperature for the same condition of superheat, evaporator temperature and condenser pressure. The entrainment ratio is also found to increase with increase of evaporator temperature keeping the boiler temperature and condenser pressure constant. The entrainment ratio does not vary much with the condenser pressure until the critical condenser pressure. It is also found that the entrainment ratio increases with decrease of throat diameter of the primary nozzle. The increase of entrainment ratio can be found out from the moving downwards of the effective position. But, a larger mass of secondary fluid causes the momentum of the mixed stream to decrease. The decrease of momentum can be determined from the moving upstream of the shocking position. The movement of shocking position upstream can cause the ejector to operate at a lower critical condenser pressure. KEYWORDS: Symmetric model, Ejector, Entrainment ratio, Throat diameter, Condenser pressure. I. INTRODUCTION A steam ejector is a device which utilizes the momentum of a high- velocity primary jet of vapour to entrain and accelerate a medium in still or at a low speed.the important functions of an ejector include maintaining vacuum in evaporation, removing air from condensers as a vacuum pump, augmenting thrust, and increasing vapour pressure as a thermal compressor. The thermal compressor is a steam ejector, but it utilizes the thermal energy to augment the performance by reducing the size of a conventional multi-stage evaporator. The steam ejector was introduced as an engineering device in the early 20th century. At the same time, researchers started to investigate its working mechanism. Keenan and Neumann [1] presented the first comprehensive theoretical and experimental analysis of the ejector problem. Xianchang Li et al. [2] carried out a numerical analysis to study about the influence of geometric arrangement on the performance of steam ejector used in conjunction with a steam evaporator. It is observed that any downstream resistance will seriously impede the suction flow rate. In addition, the entrainment ratio is sensitive to the location of the jet exit, and there is an optimum location where the primary flow should be issued. Tony Utomo et al. [3] in their study the use of steam ejector in desalination system, particularly multi effect desalination (MED) system. In this study, CFD (computational fluid dynamics) analysis based on the finite volume method was employed to investigate the influence of angle of converging duct on the ejector performance. Hisham El-Dessouky et al. [4] studied using semi-empirical models design and rating of steam jet ejectors. The model gives the entrainment ratio as a function of the expansion ratio and the pressures of the entrained vapour, motive steam and compressed vapour. E.D. Rogdakis et al. [5] discusses the behaviour of ammonia (R-717) through an ejector operating in an airconditioning system with a low temperature thermal source. The influence of three major parameters: generator, condenser and Copyright to IJIRSET www.ijirset.com 18311

evaporator temperature, on ejector efficiency and coefficient of performance is discussed. Narmine H. Aly et al.[6] studied a computer simulation model for steam jet ejectors. The model was developed by application of the equations of continuity, momentum and energy to individual operation of nozzle, mixing chamber and diffuser. B.J. Huang et al. [7] studied, two empirical correlations from the test results of 15 ejectors are derived for the performance prediction of ejectors using R141b as the working fluid. Kanjanapon Chunnanond et al. [8] studied the methods to increase the efficiency of an ejector refrigerator, a better understanding of the flow and the mixing through an ejector is needed. Shengqiang Shen et al. [9] studied a new configuration of a bi-ejector refrigeration system. The purpose of one is to suck refrigerant vapour from the evaporator and discharge to the condenser; the other acts as a jet pump to pump liquid refrigerant from the condenser to the generator. Y. Bartosiewicz et al. [10] studied numerical results of a supersonic ejector for refrigeration applications. E. Rusly et al. [11] modelled ejector designs using finite volume CFD techniques to resolve the flow dynamics in the ejectors. Szabolcs Varga et al. [12] studied about factors influencing the performance of an ejector. In this work, three geometrical factors the area ratio between the nozzle and constant area section, nozzle exit position and constant area section length were considered. This work tries to analyse the performance of a steam ejector working in conjunction with a refrigeration cycle. The operating conditions which are considered for the analyses are (i) varying the boiler temperature with constant superheat, evaporator temperature and condenser pressures, (ii) varying the evaporator temperature with constant boiler temperature and condenser pressures, (iii) varying the condenser pressure with constant boiler temperature and evaporator temperature and (iv) also three different geometry of primary nozzle are considered, corresponding steam ejector geometry model is created and meshed.the three different geometries are analyzed at the same inlet and outlet conditions. The analysis results are compared with the experimental data given in ref [8]. The results obtained from the CFD analysis can be used to study about the effective position, expansion angle and shocking position in the steam ejector. The operating conditions which were employed for the analysis ranges from boiler temperatures 120 0 C to 140 0 C, evaporator temperatures are 5 0 C 15 0 C, and condenser pressures are 25 to 45 mbar. Paper is organized as follows. Section II describes CFD simulation of the steam ejector. The processing is discussed in section III the results and discussions are in Section IV. Section V presents conclusions drawn from the present work. II. CFD SIMULATION OF THE STEAM EJECTOR The dimension of the ejector which is used for the analysis is considered from the Ref[8] and is shown in Fig. 1 and the three different primary nozzle dimensions (Fig.2) which are used for the analysis is given in table1. The detailed dimensions of steam ejector is used to build the geometry in Gambit software. The other important dimensions for creating the geometry were assumed: Suction inlet diameter = 49.2mm, Ejector outlet diameter = 40mm, Length of straight cross section after the diffuser = 20mm. The steam ejector model was developed using GAMBIT 2.4.6 software. Three 2-D Axi Symmetrical model was created according to the three primary nozzle dimension specified The model is then meshed using GAMBIT and the mesh near to the wall was refined using boundary layer meshing is given in Fig. 3. Fig.1 Steam ejector dimensions from Ref [8] Copyright to IJIRSET www.ijirset.com 18312

Fig.2 Primary nozzle dimensions Table1. Primary nozzle dimensions Nozzle no. Geometry, mm A B C D 1 2.00 8.00 25.70 7.75 2 1.75 7.00 25.70 7.75 3 0.50 6.00 25.70 7.75 a. Geometric model b. Meshed model Fig.3 The geometric and meshed model of steam ejector The primary inlet and secondary inlet were taken as pressure inlet and the ejector outlet was taken as pressure outlet. The axis was defined as the axis boundary type. And the wall boundary type was used to define the entire outer geometry. The boundary conditions employed to compare the performance of the three different geometries are for Primary inlet: Boiler temperature is 130 0 C at 232.23 kpa and the secondary inlet the evaporator temperature is 5 0 C at 800 Pa and the ejector outlet the condenser pressure is 35 mbar. Further the different operating conditions employed to compare the performance of the steam ejector are: a) Effect of condenser pressure, b) Effect of boiler temperature and c) Effect of evaporator temperature. a) Effect of condenser pressure: The boundary conditions used for this analysis are at the primary inlet the boiler temperature is 130 0 C at 232.23 kpa, at the secondary inlet the evaporator temperature is 10 0 C at 1200 Pa and at the Ejector outlet three different cases of condenser pressure are considered 25 mbar, 35 mbar and 45mbar. b) Effect of boiler temperature: The boundary conditions used for this analysis are at the primary inlet three different cases of boiler temperature are considered 120 0 C, 130 0 C and 140 0 C respectively at 169.18 kpa, 232.23 kpa and 313.22 kpa., at the secondary inlet the evaporator temperature is 15 0 C at 1700 Pa and at the ejector outlet the condenser pressure of 45 mbar. c) Effect of evaporator temperature: The boundary conditions used for this analysis are at the primary inlet the boiler temperature is 120 0 C at 169.18 kpa, at the secondary inlet the three different cases of evaporator temperature are considered 5 0 C, 10 0 C and 15 0 C respectively at 800 Pa, 1200 Pa and 1700 Pa and at the Ejector outlet the condenser pressure of 25 mbar. Copyright to IJIRSET www.ijirset.com 18313

III. PROCESSING The analysis was carried out in the commercial CFD package named FLUENT software. The geometry and grid system were imported to the solver FLUENT 6.3.26. The wall was set to be a stationary, non-slip wall. The fluid in the domain was set to be water vapour properties being constant. A pressure-based was used for all calculation cases. The 2-D axi-symmetric model was adopted as the spatial approach. The fluid flow was set as steady state. Though Reynolds number could be low in certain areas, the flow is generally turbulent in the computational domain. Spalart- Allmaras turbulence model, with Vorticity as eddy generation method, was employed for all calculations. Energy equation was enabled. The convergence criteria used for the analysis were: Continuity: 1e-05 X-velocity, 1e-06,Yvelocity, 1e-06, Energy: 1e-06 Nut: 1e-04,Once the properties were evaluated, the data points were written in a file. The properties for fluid and solid are given in table 2 represents the domain considered as aluminium and flow is fluid properties are mentioned for the analysis. Table2. The properties of fluid and aluminium Property Fluid Aluminium Density, kg/m 3 1.225 2719 Specific Heat( Cp), j/kg-k 1006.43 871 Thermal Conductivity, w/m-k 0.0242 180 Viscosity, kg/m-s 1.7894e-05 - Molecular Weight, kg/kgmol 28.966 - IV. RESULTS AND DISCUSSIONS The numerical analysis was designed to investigate the changing of the static pressure through the ejector axis when the parameters affecting the ejector performance were varied. The operating conditions which are considered for the analysis are 1) varying the boiler temperature with constant superheat, evaporator temperature and condenser pressures; 2) varying the evaporator temperature with constant boiler temperature and condenser pressures; 3) varying the condenser pressure with constant boiler temperature and evaporator temperature. Also three different geometry of primary nozzle are considered, corresponding steam ejector geometry model is created and meshed. The three different geometries are analyzed at the same inlet and outlet conditions. The analyzed results provide a better understanding in the working characteristics of a steam ejector. This section gives the conformity of results obtained with the experimental results. FLUENT which solves the governing conservation equations of fluid flow by finite volume formulation. It is well known that all the turbulence models currently available have their own credibility and limitations. Fig4: Comparison of simulated result with experimental result for validation Copyright to IJIRSET www.ijirset.com 18314

Fig.4 gives the simulation values and experimental values plotted simultaneously in order to study the variation between them. The three different geometries are analyzed at the same inlet and outlet conditions. It is observed that the experimental and simulated results are very close. Fig5. Shows the variation of static pressure for the three different boiler temperatures are considered. The level of superheat, the condenser pressure was set as 30 mbar and evaporator temperature was kept constant at 10 0 C for each case. The values of Entrainment Ratio(ER) for the three different boiler saturation pressure cases were calculated. The values are found to decrease with rise in boiler saturation pressure. This is due to the reason that the lower saturation pressure resulted in a smaller mass of steam leaving the primary nozzle with less velocity. This resulted in an expanded wave to fan out with smaller momentum and thus smaller expansion angle. Fig.5: Static pressure profile along ejector, effect of boiler temperature This caused a longer and larger entrained duct which resulted in the increase of entrainment ratio. The variation of Mach number of flow for the three different cases is also plotted, and is as shown in Fig.6. From the figure it is observed that Entrainment ratio is defined as the mass flow rate ratio of secondary to primary fluid. Entrainment ratio was calculated based on the stream function; according to definition of stream function the difference of two stream function will give the amount of flow through it. This principle is used to calculate the entrainment ratio. The boiler temperature varies the behaviour of mach number is similar in all cases Fig.6: Mach number along ejector, effect of boiler temperature Fig.7 shows the variation of static pressure for the three different cases of condenser pressure considered. The boiler temperature was set as 130 0 C and evaporator temperature was kept constant at 10 0 C for each case. It was seen that the change in entrainment ratio for the three cases considered were negligible. It can be inferred that the entrainment ratio Copyright to IJIRSET www.ijirset.com 18315

is not affected by the condenser pressure. Another important inference from the figure 7 is that the shocking position moves back as the condenser pressure increases. And this might cause disturbance to the mixing and entrainment process if it is further increased. Fig.8 shows the variation of static pressure for the three different cases of evaporator temperature considered. The boiler temperature was set as 130 0 C and condenser pressure was kept constant at 40 mbar for each case. It was seen that the entrainment ratio increases with increase in evaporator temperature. This is due to the movement of effective position to downstream with an increasingly higher evaporator temperature. The resultant longer entrained duct can handle higher amounts of secondary fluid which increases the entrainment and coefficient of performance of the refrigeration. Fig.7: Static pressure profile along ejector and effect of condenser pressure Fig.8: Static pressure profile along ejector and effect of evaporator temperature The primary nozzle dimension was varied and the steam ejector performance was studied at boiler temperature of 130 0 C, evaporator temperature of 5 0 C and at a condenser pressure of 35 mbar. Fig.9 shows the variation of static pressure along the steam ejector. The entrainment ratio was calculated and it was found that the entrainment ratio increases as the throat diameter was reduced. When a smaller primary nozzle was used, smaller amount of primary mass expanded through the primary nozzle. The enlargement of the entrained duct can be investigated from the moving downstream of the effective position. Copyright to IJIRSET www.ijirset.com 18316

Fig.9: Static pressure profile along ejector, effect of primary nozzle throat diameter. The primary mass flow rate can be calculated by subtracting the outer and inner stream function values; similar procedure is used to calculate the secondary mass flow rate. Primary mass flow rate (m p ) = [0.000552 1.5 x 10-5 ] x 2 = 1.074 x 10 4. Secondary mass flow rate (m s ) = [0.001254 0.000582] x 2 = 1.344 x 10-3. Entrainment ratio (E.R)= mp / m s = 1.25 V. CONCLUSION Based on the computational investigation to analyze the performance of a steam ejector working in conjunction with a refrigeration cycle, The CFD code employing Spallart-Allmaras turbulence model is capable of predicting the performance characteristic of the steam ejector. The Entrainment ratio (ER) is found to increase with the decrease of boiler saturation temperature for the same condition of superheat, evaporator temperature and condenser pressure. The entrainment ratio is also found to increase with increase of evaporator temperature. The entrainment ratio does not vary much with the condenser pressure until the critical condenser pressure. The shocking position is found to move backward as the condenser pressure is increased. The Entrainment ratio is also found to increase with the decrease of throat diameter. But mass of primary fluid is also reduced which results in the moving downstream of the shocking position. REFERENCES [1] Keenan, J.H. and Neumann.E.P, An Investigation of Ejector Design by Analysis and Experiment, J. Applied Mechanics, Trans ASME, 72, pp.299-309,1950 [2] Xianchang Li, Ting Wang and Benjamin Day (2010), Numerical analysis of the performance of a thermal ejector in a steam evaporator,applied Thermal Engineering, v30,pp. 2708-2717,2010 [3] Tony Utomo,Myongkuk Ji, Pilhwan Kim,Hyomin Jeong and Hanshik Chung, CFD Analysis on the Influence of Converging Duct Angle on the Steam Ejector Performance, International Conference on Engineering Optimization,2008 [4] Hisham El-Dessouky, Hisham Ettouney, Imad Alatiqi and Ghada Al-Nuwaibi, Evaluationof steamjet ejectors,chemical Engineeringand processing,v41,pp.551 561,2002 [5] E.D. Rogdakis and G.K. Alexis, Design and parametric investigation of an ejector in an air-conditioning system, AppliedThermal Engineering,v 20, pp. 213-226,2000 [6] Narmine H. Aly, Aly Karameldin and M.M. Shamloul, Modelling and simulation of steam jet ejectors, Desalination, 123, 1-8. [7] B.J. Huang and J.M. Chang (1999), Empirical correlation for ejector design,international Journal of Refrigeration,v 22,pp.379 388.,1999 [8] Kanjanapon Chunnanond and Satha Aphornratana, An experimental investigation of a steam ejector refrigerator: the analysis of the pressure profile along the ejector, Applied Thermal Engineering, v24,pp.311 322,2004 [9] Shengqiang Shen, Xiaoping Qu, Bo Zhang, Saffa Riffat and Mark Gillott, Study of a gas liquid ejector and its application to a solarpowered bi-ejector refrigeration system, Applied Thermal Engineering,n25,pp.2891 2902,2005 [10] Y. Bartosiewicz, Z. Aidoun and Y. Mercadier, Numerical assessment of ejector operation for refrigeration applications based on CFD, Applied Thermal Engineering,n 26, pp.604 612,2006 Copyright to IJIRSET www.ijirset.com 18317

[11] E. Ruslya, Lu Ayea, W.W.S. Charters and A. Ooib, CFD analysis of ejector in a combined ejector cooling system, International Journal of Refrigeration,n28,pp.1092 1101,2005 [12] Szabolcs Varga, Armando C. Oliveira and Bogdan Diacon, Influence of geometrical factors on steam ejector performance A numerical assessment, International journal of refrigeration, n32,pp.1694 1701,2009 BIOGRAPHY T.Aravind is M.Tech Thermal Engineering Department of mechanical engineering From affiliated JNTU College of engineering, Hyderabad. Dr. P. Ravinder Reddy was born on August 12 th 1965, graduated in B.Tech Mechanical Engineering from Kakatiya University (1987) Warangal, M.E Engineering Design from PSG college of Technology, Coimbatore (1991) and Ph.D from Osmania University in 2001. He has 26 years of Teaching, Industrial and Research experience. He published over 205 technical and research papers in various international and national journals and conferences. He has guided 11 Ph.D scholars so far. As a facilitator for the learning process organized 27 STTPs/Workshops /FDPs /SDPs, 2 international conferences beneficial to Faculty, Researchers and Industry and delivered 105 keynote and invited talks. Was a chief and principal investigator for 17 research and 27 industrial consultancy projects sponsored by AICTE, UGC, NSTL, DRDL, BHEL, RR Industries, ICOMM Tele services and ACD communications. He is a recipient of Raja Rambapu Patil National award for promising Engineering Teacher by ISTE for the year 2000 in recognition of his outstanding contribution in the area of, Excellence A Grade awarded by AICTE monitoring committee (2003) for the MODROB project sponsored by AICTE, Engineer of the year Award- 2004 for his outstanding contribution in Academics and research by the Govt. of Andhra Pradesh and Institution of Engineers (India), AP State Centre on 15th September 2004 on the occasion of 37th Engineer s Day, Best Technical Paper Award in the year Dec. 2008 in Industrial Application titled Online quality monitoring welding &weld upset in resistance projection welding process, in Journal of Non-Destructive Testing &Evaluation, the official journal of ISNT during the year 2007 by National Governing Council of Indian Society for Non Destructive Testing Copyright to IJIRSET www.ijirset.com 18318