Server Platform Optimized for Data Centers



Similar documents
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

FUJITSU Enterprise Product & Solution Facts

How To Buy An Fujitsu Primergy Bx400 S1 Blade Server

How to Calculate a Data Center's Energy Conservation Rate

Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes

Datasheet FUJITSU Integrated System PRIMEFLEX for Hadoop

Overview of Next-Generation Green Data Center

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

FOR IMMEDIATE RELEASE

WHITE PAPER Server Innovations: Examining DC Power as an Alternative for Increasing Data Center Efficiency and Reliability

Data Sheet Fujitsu PRIMERGY BX600 S3 Blade Server

Motherboard- based Servers versus ATCA- based Servers

NTT Com Asia deploys NEC's Express 5800/ECO CENTER to become more competitive.

Fujitsu PRIMERGY BX600 S3 Blade Server

Optimization of IT Load and Facility Energy in Data Centers

Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 CX120 S1 The Cool-Central Architecture

Solve your IT energy crisis WITH An energy SMArT SoluTIon FroM Dell

Green Data Centre: Is There Such A Thing? Dr. T. C. Tan Distinguished Member, CommScope Labs

NEC Micro Modular Server Introduction. NEC November 18,2014

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server

CarbonDecisions. The green data centre. Why becoming a green data centre makes good business sense

Technical Brief: Egenera Taps Brocade and Fujitsu to Help Build an Enterprise Class Platform to Host Xterity Wholesale Cloud Service

How To Build An Hpl Data Center

Data Center Efficiency in the Scalable Enterprise

How To Write An Article On An Hp Appsystem For Spera Hana

Microsoft Private Cloud Fast Track Reference Architecture

Datasheet FUJITSU Integrated System PRIMEFLEX for Hadoop

Managing Data Centre Heat Issues

Fujitsu - the smart choice for education

Office of the Government Chief Information Officer. Green Data Centre Practices

PRIMERGY server-based High Performance Computing solutions

Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes The Cool-Central Architecture

Global Headquarters: 5 Speen Street Framingham, MA USA P F

Data center upgrade proposal. (phase one)

Improving Economics of Blades with VMware

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

Fujitsu PRIMERGY Servers Portfolio

Green Data Center and Virtualization Reducing Power by Up to 50% Pages 10

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

Reducing Data Center Energy Consumption

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis

Desktop Consolidation. Stéphane Verdy, CTO Devon IT

Operating System for the K computer

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Fujitsu PRIMERGY BX Blade Server

Fujitsu. Make IT Dynamic Fujitsu s EASY Solution Bundles

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

WHITE PAPER Delivering Improved Energy Efficiency for the Datacenter

Fujitsu PRIMERGY Servers Portfolio

Data Center Facility Basics

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Airflow Simulation Solves Data Centre Cooling Problem

SUN BLADE 6000 CHASSIS

Power and Cooling Innovations in Dell PowerEdge Servers

APC APPLICATION NOTE #112

Blade Servers & Virtualization

Data Centers. Mapping Cisco Nexus, Catalyst, and MDS Logical Architectures into PANDUIT Physical Layer Infrastructure Solutions

The New Data Center Cooling Paradigm The Tiered Approach

How To Power And Cool A Data Center

Overview of Green Energy Strategies and Techniques for Modern Data Centers

DataCenter 2020: first results for energy-optimization at existing data centers

best practice guide 8 Considerations for an Energy-efficient Data Centre

Data Center Trend: Distributed Power in the White Space

On-Demand Virtual System Service

Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings

Improve Power saving and efficiency in virtualized environment of datacenter by right choice of memory. Whitepaper

Strategies for increasing data centre power efficiency

Using CFD for optimal thermal management and cooling design in data centers

Power and Cooling for Ultra-High Density Racks and Blade Servers

How Microsoft Designs its Cloud-Scale Servers

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

HPC TCO: Cooling and Computer Room Efficiency

The virtualization of SAP environments to accommodate standardization and easier management is gaining momentum in data centers.

Green Computing: Datacentres

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Cisco for SAP HANA Scale-Out Solution on Cisco UCS with NetApp Storage

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

Optical Interconnect Technology for High-bandwidth Data Connection in Next-generation Servers

Managing Data Center Power and Cooling

Energy Efficiency and Availability Management in Consolidated Data Centers

Power Supply, Cooling and Mechanical Technologies for Green IT

BRUNS-PAK Presents MARK S. EVANKO, Principal

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

Energy Saving Project for Datacenters

SUN ORACLE EXADATA STORAGE SERVER

WHITE PAPER Driving Reduced Cost and Increased Return From the Green Data Center

StreamStorage: High-throughput and Scalable Storage Technology for Streaming Data

Colocation and Cloud Hosting Solutions. Build a strong and efficient physical infrastructure that delivers service reliability and profitability

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Enabling an agile Data Centre in a (Fr)agile market

Re Engineering to a "Green" Data Center, with Measurable ROI

HUAWEI Tecal E9000 Converged Infrastructure Blade Server

Power Consumption and Cooling in the Data Center: A Survey

Utilizing Temperature Monitoring to Increase Datacenter Cooling Efficiency

Green Computing: Datacentres

GUIDE TO ICT SERVER ROOM ENERGY EFFICIENCY. Public Sector ICT Special Working Group

Transcription:

Platform Optimized for Data Centers Franz-Josef Bathe Toshio Sugimoto Hideaki Maeda Teruhisa Taji Fujitsu began developing its industry-standard server series in the early 1990s under the name FM server and has been marketing these servers globally since 2000 as PRIMERGY servers. Using mainly the Intel architecture in its hardware and supporting standard operating systems having a high industry share like Windows and Linux, the PRIMERGY series continues to provide an extensive lineup of servers to meet diverse customer needs. This paper outlines the features of the PRIMERGY series of servers and describes the energy-saving and cooling technologies of the PRIMERGY CX1000 platform optimized for data centers. 1. Introduction To meet a wide array of customer needs, Fujitsu is using the latest technologies for its PRIMERGY industry-standard servers and providing diverse types of servers, enabling the most optimal ones to be selected for target applications. The outsourcing business has been attracting attention for some years now, and data centers are coming to deploy a huge number of servers whose performance and mounting density have been improving dramatically. As a result, total power consumption in data centers has been increasing, cooling costs to dissipate the heat emitted by servers have been rising, and the space needed for cooling (cold aisles, etc.) is increasing. At the same time, the high-density complex design of server interiors is resulting in longer maintenance times to deal with failures. In response to these problems, Fujitsu has developed and been shipping the PRIMERGY CX1000 (hereinafter, CX1000) industry-standard server platform for data-center use featuring a new architecture. This paper outlines the entire PRIMERGY product group and describes how Fujitsu is solving these data-center problems with the CX1000 server platform. 2. Features of PRIMERGY series The PRIMERGY series of servers has been developed in accordance with customer needs. It features an extensive lineup of servers in three types tower, rack, and blade that enables the customer to use different servers for different usage scenarios in an optimal manner. 1) Tower servers PRIMERGY tower servers are usually set up in or close to offices. Featuring whisperquiet operation, extendibility, versatility, and a compact configuration, they target business operations of various scales. To achieve quiet operation, special care has been paid to the layout of cooling fans and internal components inside the servers, and a structure that promotes the flow of cooling air straight through the server housing (straight cooling architecture) has been used. This is because air flows that bend generate cooling losses and noise. 186 FUJITSU Sci. Tech. J., Vol. 47, No. 2, pp. 186 191 (April 2011)

F. Bathe et al.: Platform Optimized for Data Centers 2) Rack servers Rack servers have been developed for industry-standard 19-inch racks with the expectation that large numbers of them will be installed in data centers. The idea is to provide high performance, extendibility, and versatility along with energy-saving features. In this regard, achieving high performance and high functionality by high-density mounting within a limited volume of space has become an important objective, but the amount of energy needed for cooling purposes increases as the mounting density rises, which means that more electric power is consumed by the equipment. Fujitsu has therefore designed recent rack-type servers to minimize power consumption by increasing the area of intake vents, using power supplies having good power-conversion efficiency and voltage regulator modules (VRMs), and using low-power-consuming central processing units (CPUs) and memory modules. These design measures make up Fujitsu s Cool Safe energysaving cooling concept, which supports the entire family of PRIMERGY servers. 3) Blade servers While blade servers are developed for installation in data centers like rack servers, they aim, in particular, to achieve high server and firmware manageability to provide flexible support when equipment failures occur or business load fluctuates. Blade servers have therefore been designed to provide high levels of performance, availability, and operability as demanded by large-scale system operations. blades, storage blades, and other types of blades can be densely mounted, which improves extendibility, and chassis-mounted components can be modularized and deployed in redundant configurations. In short, blade servers aim for high availability and ease-of-use despite high-density mounting. From an operation perspective, blade servers take environmental aspects into account by providing energy-saving controls and visualization of energy usage. 3. market trends As server performance continues to advance, consolidation by server virtualization and integration has been accelerating. According to a survey conducted by Gartner, Inc., 1) Cloudoriented servers are expected to account for about 28% of all servers shipped in 2012. At the same time, infrastructures such as data centers that support server consolidation are coming to suffer from two main problems as servers increase dramatically in number and come to be arranged in high-density layouts. 1) Rising operating costs Cost of energy for running servers and air conditioning, cost of space for housing a huge number of servers, and cost of labor for maintaining and managing servers 2) Facility limitations Limits on available power, floor load capacity, and cooling capacity To solve these problems, Fujitsu has been developing its servers on the basis of the concept of simple designs specialized for data centers. 4. Development objectives for data-center-dedicated servers This section describes Fujitsu s development objectives for servers to be used in data centers aiming for scale-out computing and its approach to meeting those objectives. There are three main development objectives as described below. 1) Reduced operating costs Operating costs will be reduced in three ways: by reducing power consumption by using server nodes with fanless specifications based on a comprehensive energy-saving design; by enabling failed server nodes to be replaced on-site on a node-by-node basis; and by grouping cable connections at the front of the rack to simplify maintenance, shorten system maintenance time, and improve operating efficiency. 2) Reduced facility investment Facility deployment expenses will be reduced by increasing the server-mounting density and FUJITSU Sci. Tech. J., Vol. 47, No. 2 (April 2011) 187

F. Bathe et al.: Platform Optimized for Data Centers saving space by reducing the rack footprint and increasing the number of servers that can be accommodated by a rack and by enabling a back-to-back rack setup to eliminate the need for hot aisles behind racks, which are used in conventional layouts. The idea is to provide a simple structural design and the ability to replace main boards on-site so that subcomponents can be used more effectively and server installation (in terms of cooling and cable connections) can be optimized for data-center infrastructures. These measures will help to keep down initial deployment costs and reduce facility costs. 3) Simplified maintenance and operations Maintenance and operations have already been simplified by enabling customers themselves to replace nodes, and flexibility and customization capabilities have been provided. Since supporting inherited existing technologies and facilities is an important element of system deployment, support for a front-to-back cooling infrastructure can be provided to maintain compatibility with existing data-center layouts. Moreover, a plug-and-play design is also provided for server nodes to enable on-site replacement and general-purpose properties can be built in to make it easy to reuse standard main boards. Design specifications are also adaptable to future delivery models. The following specific techniques help to reduce costs and power consumption by optimizing the rack structure and adopting simple specifications. 1) Reduced use of cooling fans While 304 compact fans were needed in the past (RX200: 8 fans 38 nodes), the development of a dedicated rack with optimized cooling efficiency enables cooling requirements to be met by two large fans. 2) High-efficiency power supply To support a high-conversion-efficiency 200-V power-supply environment, Fujitsu uses a power supply with a power-conversion efficiency of 92% (conforming to CSCI gold and 80 PLUS Gold at 50% load) achieved by using highefficiency standard parts and materials. 3) New cooling system Fujitsu has achieved a high-density rack setup by changing the conventional rear-exhaust design to a top-exhaust one. As a result, there is no need to allocate space for hot aisles, which enables a 40% reduction in rack setup space. 5. CX1000 features and performance This section introduces development concepts and product features of the CX1000 platform, which is optimized for data centers. 5.1 Concepts and features (improvements over existing servers) 5.1.1 Concepts There are three key concepts: the server design is optimized for large scale-out in Cloud environments; the same housing size as for standard 19-inch racks is used, enabling installation alongside existing servers in a data center; and the need to allocate space behind racks for expelling heat and performing maintenance work, as in existing data centers, is eliminated. 5.1.2 Features There are three key features: a server-node design with a power supply unit on each node to reduce material costs and weight; an innovative cooling system featuring central exhaust fans and chimney-type air flow and a simplified rack structure; and a small rack footprint (850 mm 700 mm) and a rack structure conducive to a back-to-back arrangement, which doubles the server-node density per unit area in the data center (Figure 1). 5.2 CX1000 deployment effects Compared with other rack servers, the CX1000 has a 40% smaller footprint and uses 13% less energy, which produces the following 188 FUJITSU Sci. Tech. J., Vol. 47, No. 2 (April 2011)

F. Bathe et al.: Platform Optimized for Data Centers effects. Its independent nodes are unaffected by faults in other nodes (shorter mean time to repair). No space is needed in the data center for hot aisles. The maximum number of racks per unit area is higher. There are no extra costs for unused functions, which reduces facility and operating costs. The CX1000 has the lowest power consumption and highest energy efficiency among scale-out-type data-center architectures. Exhaust Exhaust Cold aisle Cold aisle Cold aisle Intake Intake Intake Back-to-back arrangement Floor 5.3 CX1000 configuration The CX1000 rack features a simple and highly cost-efficient design that significantly improves energy efficiency per rack compared with existing rack designs. can be mounted in one rack. Up to 38 nodes Its simple and highly cost-efficient design makes the CX1000 server node a highly flexible, energy-efficient component (Figure 2). This server node uses a standard 13-inch 12-inch main board and a high-efficiency VRM and has a fanless structure. It can also accommodate different types of CPUs and smaller main boards, reflecting its generalpurpose properties. 5.4 Cooling technology for energy-saving effects The CX1000 has a centralized cooling system for the entire rack that holds down power consumption (Figure 3). In contrast to existing rear- and front-exhaust systems, this system has fans for cooling the entire rack positioned on top of the rack to direct exhaust air upwards. In addition, the aperture ratio of the exhaust vents differs between the top and bottom of the rack to Figure 1 Overview of back-to-back arrangement and cooling system. Power supply Main board Memory slots Top CPUs Hard disk drive PCI slot PCI: Peripheral Component Interconnect Front Top seen from rear interior Figure 2 node. Figure 3 Appearance of CX1000 and its large central cooling fans. FUJITSU Sci. Tech. J., Vol. 47, No. 2 (April 2011) 189

F. Bathe et al.: Platform Optimized for Data Centers socket Xeon 5500 series server class. 2) adjust the airflow and provide uniform cooling across all server nodes (Figure 4). This rack structure was designed and tested by heating/ cooling computer-simulation technology. 5.5 Performance The CX1000 set a world record at 2320 overall ssj_ops/watt note 1) in tests performed using the benchmark test program SPECpower_ ssj2008 note 2) on April 7, 2010. This achievement demonstrates that the CX1000 has the highest energy efficiency and performance in the twonote 1) note 2) Small aperture ratio Large aperture ratio Uniform cooling structure Number and size of rear vents change from top to bottom Figure 4 Rear exhaust vents aperture ratios. A unit of computer-system throughput (performance) per watt. A benchmark test program developed by the Standard Performance Evaluation Corporation (SPEC) for evaluating energy efficiency by assessing both the power consumption and performance characteristics of a general-purpose server. It indicates server performance per watt where a high value means high efficiency. 5.6 Energy-cost reduction effect The CX1000 has achieved an energy-cost reduction effect of 1.23 billion yen in three years and the average amount saved annually is about 400 million yen (about 20%) for a large-scale data center (10 000 server nodes). This is composed of 210 million yen representing the annual saving calculated as a proportion of the one-off infrastructure creation saving for hardware procurement (about 15% less than with existing models), annual savings of 120 million yen (about 40% less than with existing models) for floor-space charges (facilities), and 80 million yen for reduced power consumption (up to 7.5 million kwh less [about 25% less annually] than for existing models). 6. Future issues As a server, the CX1000 is targeted at data centers that aim for scale-out computing, and as a platform, it provides an optimal solution for constructing Cloud computing environments and data centers. From here on, Fujitsu will pursue the development of three key techniques to deal with the increasing diversity of data-center applications: multi-node techniques, control techniques for decreasing power consumption in racks, and localized cooling techniques for precise equipment cooling. 7. Conclusion This paper introduced the PRIMERGY CX1000 server platform developed to meet data-center needs. It provided some background to product development, described new technologies developed to meet design targets, and discussed the effects achieved. Since the product announcement in spring 2010, Fujitsu has received questions and inquiries from many data centers, and new issues related to product deployment have become clear. Looking forward, Fujitsu intends to resolve these issues to deal 190 FUJITSU Sci. Tech. J., Vol. 47, No. 2 (April 2011)

F. Bathe et al.: Platform Optimized for Data Centers with a higher level of customer needs and to perform surveys and research and development to respond flexibly to future trends such as the modularization of data centers. References 1) Gartner: Dataquest Insight: The Impact of Cloud Computing on Sales, 2009 Update. Adrian O Connell, 25 November 2009. http://www.gartner.com/ DisplayDocument?id=1236313 2) Fujitsu Press Release: Fujitsu s PRIMERGY CX1000 Sets Ground-Breaking SPECpower Benchmark in 2-Socket Xeon 5500 series server class. http://ts.fujitsu.com/ps2/press/read/ news_details.aspx?id=4157 Franz-Josef Bathe Fujitsu Technology Solutions Mr. Bathe is engaged in drafting specifications for next-generation data center products. Hideaki Maeda Fujitsu Ltd. Mr. Maeda is engaged in the development of industry-standard server equipment. Toshio Sugimoto Fujitsu Laboratories Ltd. Mr. Sugimoto is engaged in the research and development of elemental power-saving technologies. Teruhisa Taji Fujitsu Ltd. Mr. Taji is engaged in drafting specifications for PRIMERGY products. FUJITSU Sci. Tech. J., Vol. 47, No. 2 (April 2011) 191