Model 7000 Master Programming Mode



Similar documents
7000 Master Programming Mode

SE Timer - V2.0 Master Programming Mode Flow Chart

ECONOFLO 5600SXT SOFTENER Model 5600 SXT-User Programming Chart Time of Day. Model 5600 SXT -User Programming Chart

Autotrol 460i and 460TC Control System

Master Programming Manual for TotalCare, CareSoft Elite, CareSoft Pro, Ion Pro and CareClear Pro Models

Fleck 7000SXT. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET

Cat. No Rev. A 09/24/02 DCO# Service Manual. Models From Culligan International Company Printed in U.S.A.

Owner s Manual / 5600 Econominder

Global New Product Development EWT 610HE/611HE Model

Model 5600SE Downflow

Operation Manual. 740/760 Control 255 and Performa Series Valves (268, 268FA) For Sales & Service questions please contact your dealer:

MASTER. Water Conditioning Corp. MP-MBA-15T-30T using the 255/762 Logix Control Valve. Installation and Operation Manual.

OWNER S MANUAL. Deluxe Demand Water Softeners MODEL NOS

Metermatic SE Automatic Water Softener. Operation Manual

Water Specialist 1 Control Valve Series Model: WS1

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual.

Clean Water Made Easy

MASTER. Installation and Operation Manual. Water Conditioning Corp. MCA Time Clock Series Residential Softeners. February 2011 Version

10/20 COMBINATION UNIT

What's a backup cycle?

Operations Manual. Models: 269 Counter-Current Conditioner

Model 5600 & 5600 Econominder

E-969 ENCODER. Outdoor Warning. Installation & Operating Manual E-969 E STAND BY MODE MONDAY 01:45:02 SEND ENGINEERING COMPANY INC.

Model 5600 & 5600 Econominder

Backup Tab. User Guide

INSTALLATION AND SERVICE MANUAL

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

WHAT ELSE CAN YOUR HOME PHONE DO?

One positive experience I've had in the last 24 hours: Exercise today:

COIN V-SERIES AND EXPRESS- SERIES PROGRAMMING INSTRUCTIONS

Using the EBS SQL Import Panel

IBM i Version 7.2. Systems management Advanced job scheduler

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Operation Guide 3M-22

Fleck 7000 Softener Installation & Start-Up Guide

CHAPTER 11: Flip Flops

Time Clocks WARNING. For Repair or Service

Neonixie 6 Digit Nixie Clock Controller Introduction and Assembly

Recurring Work Orders - Overview. Purpose. Generating Tasks

Ion Exchange Softening

U11 Boys Black March 21st Monday 6:00-7:30 p.m. Damien Training Field 2 March 24th Thursday 4:30-6:00 p.m. Damien Training Field 2 March 28th Monday 6

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

Series 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual

Iron Air Charge 2510-SXT Installation & Start-Up Guide

RXD Water Softener. Water Conditioning. Owner s Manual R4039. RXD Owner s Manual. Page 1

PAR+ES Controller. Operation Manual MANUAL LOCAL MAXI A B C D E F M1 M2

MODEL Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

TIMESHEET EXCEL TEMPLATES USER GUIDE. MS-Excel Tool User Guide

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

ProFiler Client Software User s Guide

SMC 3000 Series Master Clock Programming Manual (V3) Table of Contents. Getting Started.. Page 2. Setting the Time of Day...

INSTALLATION AND OPERATING INSTRUCTIONS

Operating and Service Manual SXT Automatic Chloramines Removal Filter. Made in Canada

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

Lab - Data Backup and Recovery in Windows XP

Non-Exempt RealTime Online Employee User Guide

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

GAUGEMASTER PRODIGY EXPRESS

DECEMBER 2015 PTAB Public Hearing Schedule

AT&T. MG9150J Issue 1 October PARTNER Plus, PARTNER II Communications System Programming Quick Reference

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

T7400. Guest Paging System. Long Range Systems, Inc Chartwell Dr., Dallas, TX V6.21 and later

485HE High Efficiency Water Softener. Proud member of Canadian Institute of Plumbing & Heating. Proud member of Canadian Water Quality Association.

7500 Pro-Ox Filter Installation & Start-Up Guide

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

WHOLESALE LOCK POLICIES

Essential Time & Attendance Supervisor Scheduling Basics

Fused Spur Time Switch

Reizen Atomic Talking Analog Alarm Clock Item # Instruction Manual

5100 Spreader Control Event Logging Installation, Calibration and Operation Manual

MODEL T600 40LB CAPACITY COMPUTER CONTROL COIN WASHER

Introducing Culligan HE. The smartest way to fix hard water problems.

Scheduler Guide. Version 4.7 April Scheduler Guide 1

Portable MP3 Player User's Guide

MP280 / MP287 / MP288 MP495 / MP497 / MP498 SERVICE REFERENCE MANUAL

Introducing the hard disc recorder and Beo4, Daily use, Advanced operation, Preference settings, Set up the hard disc recorder, On-screen menus,

BROOKFIELD MODEL VTE250 ELECTRIC VISCOSEL PROCESS VISCOMETER. Installation, Operation, and Maintenance Instructions. Manual No.

EZ DUPE DVD/CD Duplicator

WATER SOFTENER SYSTEMS

Employee Central Payroll Time Sheet

Midi Fighter Twister. User Guide. Ver 1.01 DJTECHTOOLS.COM

Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction

User s Guide for the Texas Assessment Management System

HEAT PUMP PROGRAMMABLE THERMOSTAT

Changing printer settings 1

Backup Tab. User Guide

HEALTH INFORMATION SYSTEM (HIS) Running and Scheduling Reports in InfoView (BOXI)

Time switch D21-1-channel / 32 / / 63 / General information. Overview. Set language

Cruise Line Agencies of Alaska. Cruise Ship Calendar for 2016 FOR PORT(S) = KTN AND SHIP(S) = ALL AND VOYAGES = ALL

DVR GUIDE. Using your DVR/Multi-Room DVR WAVE-123 wavebroadband.com

PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL

Microsoft Project 2013

Work with Centricity2 Mobile Communications App (MCA) Site Manager. Schoolwires Centricity2

Works. Works Quick Reference Guide. Creating and Managing Reports

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Cruise Line Agencies of Alaska. Cruise Ship Calendar for 2016 FOR PORT(S) = KTN AND SHIP(S) = ALL AND VOYAGES = ALL

Transcription:

With the Time of Day Display set to 12:01 P.M., push and hold the Set Up and Set Down buttons for 5 seconds. US/Metric Dislay Format Example: Gallons Metric [U--1] = Default [U--2] Note:. Set Time of Day Display to 12:01 P.M. 2. Push and hold the Set Up and Set Down buttons for 5 seconds. 3. Press the Extra Cycle Button once per display until all displays are viewed and normal operation is resumed. 4. Option setting display may be changed as required by pushing either the Set Up or Set Down button. 5. Depending on current valve programming, certain displays may not be viewed or set. Regenerant Flow Example: Downflow Downflow Fill First Filter [df] = Default [dfff] [Fltr] Regeneration Type Example: Time Clock Delayed [7--1] Meter Immediate [7--2] Meter Delayed [7--3] = Default Meter Delayed - Variable Brining [7--4] Days of the Week [7--5] *(Skip to Regeneration Time if [7--5] System Capacity Example: 24 Kilogram Capacity, Gallon Format [C-24] = Default 180 Degree-Liters, Metric Format [C180] *Not Applicable to [7--5] Feed Water Hardness Example: 15 Grains/Gallon [H-15] = Default 25 Degrees, Metric [H-25] *Not Applicable to [7--5] Regeneration Time Example: 2 O Clock A.M. [2:00} = Default Page

Regeneration Day Override OR Day of the Week Example: Regenerate every 7 days [A- -7] Cancel Setting [AOFF] = Default [Day X] (where X = 1 through 7) Set to Current Day Note: OFF not available *Day is incremented at midnight. Regeneration Cycle Step Programming (1-5) Example: 10 minute Backwash, in US Format, Downflow [1-10] 60 minute Brine Draw/Slow Rinse, in US Format [2-60] 5 minute 2nd Backwash in US Format [3- - 5] 10 minute Rapid Rinse in US Format [4-10] 12 minute Brine Refill US format [5-12] Note: All Above Settings Are Shown in Factory Default Settings Based on Downflow Regeneration Type and US-1 Display Format. Push Extra Cycle button to advance through all [D1--X} settings Note: Regeneration will occur on the day or days which are set to 1 (enabled) at the regeneration time which was set in the previous program step. Individual Day of the Week Settings: [d1--x] where x = 1: d1 enabled regeneration this day where x = 0: d1 disabled regeneration this day [d7--1] = Default *Skip to Line Frequency Setting if [7--1] or [7--5]. Flow Meter Size Example: 1-1/4 Turbine Meter, US [F-82] = Default 1-1/4 Turbine Meter, metric [F21.6] *Not applicable to [7--1] or [7--5] Safety Factor Example: 25% Safety Factor [cf25] 0% = No Safety Factor [cf-o] = Default *Not Applicable to [7--1] or [7--5]. Page 2

Line Frequency Example: 60Hz Line Frequency 50Hz Line Frequency [LF60] = Default [LF50] Exit the Master Programming Mode Note: Valve Calculates Programming Changes [CALc] and Returns to the Service Position/Time of Day. Page 3

Entering Master Programming Mode Set the Time of Day to 12:01 P.M., then press and hold both the Set Up and Set Down buttons for 5 seconds. The program indicator light turns on to signal that the Master Programming Mode is entered. All program steps may be programmed in this mode. Use the Set Up and Set Down buttons to change all settings. Press the Extra Cycle button to advance to the next program step. 1. US / Metric Display Format (Display Code u) Use this program step, identified by the letter U in the first digit of the display, to set the desired display format. There are two possible display settings: US = gallons of water and grains of hardness Setting: [ u - - 1 ] Metric = liters of water and degrees of hardness Setting: [ u - - 2 ] 2. PISTON / CAM Type (Display Code df, dfff, Fltr) Default = US [ u - - 1 ] Use this program step to set the desired piston type. The letters in the display stand for the following piston types: df: down flow dfff: down Flow Fill First Fltr: Filter Default: [ df ] down flow Use the Set Up and Set Down buttons to select the desired piston type. Note: If the US/metric setting or piston/cam type is changed, the valve auto-homes after exiting from the Master Programming Mode. 3. Regeneration Type (Display Code 7) Use this program step, identified by the number 7 in the first digit of the display, to set the Regeneration Type. There are 4 possible settings: Time Clock Delayed Setting: [ 7 - - 1 ] The control regenerates on the days set in program step #7, at the Regeneration Time set in program step #6. Meter Immediate Setting: [ 7 - - 2 ] The control regenerates immediately when the available volume of softened water drops to 0. Meter Delayed Setting: [ 7 - - 3 ] The control regenerates on the day the available volume of softened water drops to less than the reserve volume. Regeneration starts at the Regeneration Time set in program step #6. Meter Delayed - Variable Brining Setting: [ 7 - - 4 ] The control regenerates on the day that the available volume of softened water drops to or below the reserve volume. Regeneration starts at the Regeneration Time set in program step #6. With the variable brining option activated, the time setting for Cycle 1 is automatically calculated based on the volume of treated water at the time of regeneration. Cycle time 1 will not exceed the original time setting and is never less than 1 minute. Page 4

Day of the Week Setting: [7--5] The control regenerates on the individual day(s) of the week which are set to 1. The regeneration will occur at the programmed regeneration time. If all of the days are set to 0, no regenerations will be initiated and the control will display an [Err2] message on the 8th day. Default = Meter Delayed Regeneration [ 7 - - 3 ] Available Regeneration Types and their Dependencies Piston/CAM Type Regeneration Types Available df [ 7 - - 1 ], [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 5 ] dfff [ 7 - - 1 ], [ 7 - - 3 ], [ 7 - - 4 ], [ 7 - - 5 ] Fltr [ 7 - - 1 ], [ 7 - - 5 ] Default: df [ 7 - - 3 ] 4. System Capacity (Display Code C) for US and metric with an extended (Display Code Ct) in metric where t denotes x 1,000 multiplier Example: Ct1.9 = 1,900,000 Note: This program step is not available for Regeneration Type Time Clock Delayed [ 7 - - 1 ] or [ 7 - - 5 ]. Use this program step, identified by the letter C in the first digit of the display, to set the capacity of the system in kilograins (or Cubic meter X degrees for metric systems). Use the system capacity to calculate the amount of treated water (gallons or liters) to be treated by the unit before a Regeneration Cycle is required. The control automatically determines a reserve capacity based on water use history when Regeneration Type is set to Meter Delayed [ 7 - - 3 ] or Meter Delayed Variable Brining [ 7 - - 4 ]. Range = 1 299 kilograins, US [ u - -1 ] Range = 1 1,900,000 degree-liters, metric [ u - - 2 ] Default = 24 kilograins, US [ u - -1 ] Default = 180 degree-liters, metric [ u - - 2 ] Example: 24 kilograin system capacity Setting: [ C 24 ] 5. Feed water Hardness (Display Code H) Note: This program step is not available for Regeneration Type Time Clock Delayed [ 7 - - 1 ] or Days of the Week [ 7 - - 5 ]. Use this program step, identified by the letter H in the first digit of the display, to set the feed water hardness. Use the Set Up and Set Down buttons to set the amount of feed water hardness. The system automatically calculates treated water capacity based on the feed water hardness entered in this program step and the system capacity entered in program step #4. Range = 4 199 grains/gallon, US [ u - -1 ] Range = 4 199 degrees, metric [ u - - 2 ] Default =24 kilograins, US [ u - -1 ] Default = 25 degrees, metric [ u - - 2 ] Page 5

Example: Feed water hardness = 20 grains/gallon Setting: [ H 20 ] Default = 15 grains/gallon [ H -15 ] 6. Regeneration Time (No display Code) Note: This program step is not available for Regeneration Type Meter Immediate [ 7 - - 2 ]. Use this program step to set the Time of Day a Regeneration occurs. A non-flashing colon between the hour and minute digits identifies the Regeneration Time display. Range = 12:00 11:59 P.M., US Range = 00:00 23:59, metric Example: 2 o clock A.M. regeneration time Setting: [ 2:00 ] Default = 2:00 A.M. Note: When the piston type is Fltr, Regeneration time defaults to: 12:00 A.M., US 00:00, Metric 7. Regeneration Day Override (Display code A): [ 7 - - 1 ], [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ] ONLY Use this program step, identified by the letter A in the first digit, to set the maximum number of days the unit can be In Service without a regeneration. For Regeneration Type Time Clock Delayed [ 7 - - 1 ], the system regenerates at the time set in program step #5 after the number of days programmed in this step. For any Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ], the system regenerates after the number of days programmed in this step at the Regeneration Time setting, step #6. Range = 0 99, Time Clock Delayed [ 7 - - 1 ] Range = 1 199, Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ] Default = 7 days, Time Clock Delayed [ 7 - - 1 ] Default = Meter Regeneration Types [ 7 - - 2 ], [ 7 - - 3 ], [ 7 - - 4 ] Example: Override every 7 days Setting: [ A -- 7 ] Option turned off Setting: [ A OFF ] 8. Day of the Week: [ 7 - - 5 ] ONLY (Display Code day x ) where x is one (1) to seven (7) Use this program step, identified by the word Day, to set the current day of the week. The user can select any number in the range of 1 through 7 to represent the current day of the week. The current day number will increment each day at midnight. Default = Day 7, Day of the Week [ 7 - - 5 ] Example: Monday = Day 1; Tuesday = Day 2; Wednesday = Day 3; Thursday = Day 4; Friday = Day 5; Saturday = Day 6; and Sunday = Day 7 Page 6

9. Regeneration Cycle Step Programming (Display Code 1 6) Use this program step to program the Regeneration Cycle step times. The number of Regeneration Cycle steps available is determined by the Piston/Cam type selection entered in step #1. The Regeneration Cycle step being programmed is shown in the first digit of the display. Each display is used to set the duration time in minutes of that specific step in the Regeneration Cycle. Range = 0 199 minutes, US [ u - -1 ] Range = 0 199 minutes, metric [ u - - 2 ] Default Times for all of the Available Piston/Cam Types Regeneration Cycle Step Times, in minutes, depend on the Piston / Cam selected. Cycle Step df dfff FLtr 1 10 = Backwash 12 = Fill 10 = Backwash 2 60 = Brine Draw 60 = Brine Making 10 = Rapid Rinse 3 5 = 2nd Backwash 10 = Backwash 4 0 = Rapid Rinse 60 = Brine Draw 5 12 = Refill 5= 2nd Backwash 6 0 = Rapid Rinse Note: Cycle step #1 minimal setting is 1 minute. 10. Regeneration Day Setting [ d1 - -x ] [ d2 - -x ] [ d3 - -x ] [ d4 - -x ] [ d5 - -x ] [ d6 - -x ] [ d7 - -x ] Where x can be set to 1 or 0. Regenerations will occur at the programmed regeneration time on the day(s) which are set to 1. Regenerations will not occur on days which are set to 0. If all days are set to 0, a regeneration will never occur and the control will display [Err2] on the 8th day. To clear this error, the user must program at least one day of the week for regeneration or manually initiate a regeneration. 11. Flow Meter Size (Display Code F) Note: This program step is not available for Regeneration Type Time Clock Delayed [ 7 - - 1 ]. Use this program step, identified by the letter F in the first digit, to set the flow meter size. This program step sets the proper number of pulses generated by the flow meter for each gallon or liter of water flow. Range = 0 999 pulses per gallon, US [ u - -1 ] Range = 0 99.9 pulses per liter, metric [ u - - 2 ] Default = 82 pulses per gallon, US [ u - - 1 ] Default = 21.6 pulses per liter, metric [ u - - 2 ] Page 7

Example: -1/4 Turbine Meter, US [ u - -1 ] Setting: [ F 82 ] -1/4 Turbine Meter, metric [ u - - 2 ] Setting: [ F 21.6 ] 12. Safety Factor (Display Code cf) Use this program step to provide a safety margin by lowering the available capacity. The setting is in percentage and ranges from 0 50%. Example: [ cf 0 ] 0% = No safety factor [ cf 35 ] 35% = The available capacity is lowered by 35% Default: [ cf 0 ] 0% = No safety factor Note: This program step is not available in the Time Clock mode [ 7 - - 1 ] or the Day of the Week Mode [ 7 - - 5 ]. 13. Line Frequency (LF) Use this program step, identified by the letters LF in the first digit of the display, to set the frequency of the power supply. When the line frequency is set properly, all timekeeping functions remain accurate. There are two possible settings: 60Hz Line Frequency Setting: [ L F 60 ] 50Hz Line Frequency Setting: [ L F 50 ] Default = 60 Cycles (program step #2 = u1) Default = 50 Cycles (program step #2 = u2) Exiting the Master Programming Mode Press the Extra Cycle button once more to exit the Master Program Mode and resume normal operation. Finish the control programming by completing the Control Start-up procedures in the service manual. Note: If any changes are made to the Piston/Cam setting during the Master Programming Mode, the valve auto-homes when exiting the Master Programming Mode. If any changes were made to capacity, hardware or safety factor settings, the control recalculates the System Capacity and sets the Starting Reserve to one-third of the new value. Page 8

Error Codes Note: Error codes appear on the In Service display. Error Code Probable Cause Recover and Resetting [Err 0] Drive motor is stalled Unplug the unit from the power source [Err 1] Drive motor is running continuously When power is restored to the unit, the Err _ display code clears. If the condition causing the error has not been resolved the Err _ code reappears in the four digit display. Do not attempt to troubleshoot this problem any further. [Err 2] There have been more than 99 days since the last Regeneration. If the Day of the Week mode of regeneration is selected and days since last regeneration exceeds 7 days. Regeneration must occur for the unit to recover, the display to clear and the valve to function normally. [ 7 - - 5 ]: There have been more than 7 days since the last regeneration. All individual settings (d1, d2, d3, d4, d5, d6, d7) are set to 0. [ 7 - - 5 ]: To recover from [Err2], the user must initiate a regeneration or set at least one individual day to 1. Resetting The Program To The Default Settings To reset the controller to the default settings press and hold the Set Up and Set Down buttons for 25 seconds or until the Time of Day display resets to 12:00 P.M. This resets all program step settings to the default values. The program steps must then be reset using the Master Programming procedure in these instructions. Note: A Master Reset causes the valve to auto-home. Page 9

Notes: P/N 41079 Rev. F 4/06