Web Machine Interface



Similar documents
Contents. 1 VPN Remote Access Service

Chapter 6 Configuring the SSL VPN Tunnel Client and Port Forwarding

Quick Note 026. Using the firewall of a Digi TransPort to redirect HTTP Traffic to a proxy server. Digi International Technical Support December 2011

Configuring PDM. Starting PDM with Internet Explorer CHAPTER

C-more Remote Access with Apple ipad or iphone Tutorial

How to add a SIP server How to register a handset

Remote PC Guide for Standalone PC Implementation

BabyWare Imperial PC Software

Quick Guide of DDNS Settings

emerge 50P emerge 5000P

GV-iView HD V1 for ipad

1. Introduction What is Axis Camera Station? What is Viewer for Axis Camera Station? AXIS Camera Station Service Control 5

19 LCD / 8 CHANNEL DVR COMBO WITH 160GB HDD & 4 CAMERAS

NF1Adv VOIP Setup Guide (for Pennytel)

Instructions for transferring the SINUMERIK HMI to an external screen

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

H3C SSL VPN RADIUS Authentication Configuration Example

801.11n Wireless Broadband Router

NF1Adv VOIP Setup Guide (for Generic VoIP Setup)

Using Remote Desktop Software with the LAN-Cell

Quick Guide of HiDDNS Settings (with UPnP)

How to put the DVR online

802.11n Wireless Broadband Router WNRT-625

IP EQUIPMENT WEB. User manual

NAS 224 Remote Access Manual Configuration

APNT#1184 WAN or Internet Access to GP-Pro EX. Introduction

Setting Up Scan to SMB on TaskALFA series MFP s.

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

Cisco QuickVPN Installation Tips for Windows Operating Systems

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

Setting up VPN Access for Remote Diagnostics Support

Elluminate Live! Access Guide. Page 1 of 7

Talk2M Free+ Remote-Access Connectivity Solution for ewon COSY devices. Getting Started Guide

Technical Notes TN 1 - ETG FactoryCast Gateway TSX ETG 3021 / 3022 modules. How to Setup a GPRS Connection?

2012/02/10: Re-formatted and revised document 2012/01/05: Added figures and notes 2011/11/08: Initial release

Using Remote Desktop with No-IP

Chapter 10 Troubleshooting

UIP1868P User Interface Guide

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

OUTDOOR IR NETWORK CAMERA Series

138 Configuration Wizards

Verizon Remote Access User Guide

Quick Guide of DDNS Settings

Easy Setup Guide for the Sony Network Camera

Configuring Check Point VPN-1/FireWall-1 and SecuRemote Client with Avaya IP Softphone via NAT - Issue 1.0

Barracuda Link Balancer

TENVIS Technology Co., Ltd. User Manual. For H.264 Cameras. Version 2.0.0

M2Web - Browser-Based Mobile Remote Access

Elluminate Live! Access Guide. Page 1 of 7

Network setup and troubleshooting

NF3ADV VoIP Setup Guide (for TPG)

IS SERIES. QuikStart Programming Guide. IP Network Direct System. Programming Videos

Using Remote Desktop Software with the LAN-Cell 3

TECHNICAL NOTE TNOI27

Chapter 6 Using Network Monitoring Tools

About the Canon Mobile Scanning MEAP Application

Protecting the Home Network (Firewall)

Networking Guide Redwood Manager 3.0 August 2013

SSL Web Proxy. Generally to access an internal web server which is behind a NAT router, you have the following two methods:

MFC7840W Windows Network Connection Repair Instructions

Connect to a SQL Database with Monitouch

Port Forwarding your Router for Use with a Network DVR

AXIS 262+ Network Video Recorder

Linksys E2000 Wireless-N Router Configuration Guide

NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)

Configuration and Access of FTP Server

Download and Launch Instructions for WLC Client App Program

The Register Menu allows you to register, download, and activate licenses so that your players can run.

Debug Failed to connect to server!

Figure 41-1 IP Filter Rules

Appendix C Network Planning for Dual WAN Ports

Network Setup Guide. 1 Glossary. 2 Operation. 1.1 Static IP. 1.2 Point-to-Point Protocol over Ethernet (PPPoE)

NF5 VOIP Setup Guide (for Generic)

Accessing Remote Devices via the LAN-Cell 2

이 기기는 업무용 급 으로 전자파적합등록을 한 기기이오니 판매자 또는 사용자는 이점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다

Application Note. Onsight TeamLink And Firewall Detect v6.3

Troubleshooting Remote Viewing on the. Combo DVR/Monitor System

FTP Server Application Guide REV:

Network Configuration Settings

Internet and Intranet Calling with Polycom PVX 8.0.1

V310 Support Note Version 1.0 November, 2011

UC-One. Epik. UC-One Quick Guide. Quick Guide For Apps. Why we love UC-One

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Using SonicWALL NetExtender to Access FTP Servers

MULTIFUNCTIONAL DIGITAL SYSTEMS. TopAccess Guide

Chapter 6 Using Network Monitoring Tools

How to Setup and Connect to an FTP Server Using FileZilla. Part I: Setting up the server

Setting up the Swann HD IP cameras

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Bosch Video Management System

Creating a Client-To-Site VPN. BT Cloud Compute. The power to build your own cloud solutions to serve your specific business needs.

Quick Connect. Overview. Client Instructions. LabTech

BASIC ANALYSIS OF TCP/IP NETWORKS

DIVAR IP 3000 / Video Management Appliance and Bosch Video Security Mobile APP

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

How To Check If Your Router Is Working Properly

Step-by-Step Setup Guide Wireless File Transmitter FTP Mode

Instructions Microsoft Outlook Express Page 1

How To Remotely View Your Security Cameras Through An Ezwatch Pro Dvr/Camera Server On A Pc Or Ipod (For A Small Charge) On A Network (For An Extra $20) On Your Computer Or Ipo (For Free

Polycom Phones User Guide Bicom Systems

Transcription:

From Human Machine Interface to Web Machine Interface - Innovation of HMI - -1- Copyright 2014 All Rights Reserved.

Web Machine Interface offers two services below: remote access service cloud data utilization service (under development) -2- Copyright 2014 All Rights Reserved.

Why don t you start the remote access by? Implementing the remote access on your system can be the strong tool to differentiate competitor with the internet solution. Before After Error * When trouble was occurred at site, it was required to visit there by spending your time and money for the trouble shooting. * When trouble was occurred at site, it is possible to understand the situation of the site without visiting there. -3- Copyright 2014 All Rights Reserved.

Challenges on remote connection Remote monitoring/maintenance has a variety of challenges China Internet Japan When we actually consider adopting it How much will it cost? Router How can we set up the devices? What devices are needed? Ethernet -4- Copyright 2014 All Rights Reserved.

Conventional system example (IP-Sec ) What devices and settings do we need to achieve safe remote maintenance? Factory (Installed site) Monitoring site (office) Internet IP address 192.168.1.1 V8 192.168.1.10 router router A: PC Challenge 2 Settings required * It is need to set the router as Installing site. Challenge 1 router needed * router is needed for both monitoring and installed sites. Existing router must be replaced with a router. (Network skill is required) Challenge 3 Settings required * It is need to set the router as Monitoring site. (Network skill is required) 192.168.1.11 Network camera 192.168.1.12-5- Copyright 2014 All Rights Reserved.

System example with V9 V9 has a built-in router, so external router is not required. Factory (Installed site) Required setting (2) setting on V9 * Set the router s IP address for the default gateway on V9 setting. Monitoring site (office) IP 192.168.1.1 IP 192.168.1.100 GW 192.168.1.1 2 IP 192.168.90.1 A: PC Router Use the router which you use currently. ( Server) Router Use the router which you use currently. V9 IP 192.168.90.11 GW 192.168.90.1 Network camera Required setting (1) Setting of the management tool V-Connect * Set domain name, user ID and password on the software. * Register the setting of the local network for connecting to 2 on V9. Required setting (3) setting on V9 * Register target ID, node ID and node password which are informed by Hakko to V9. Required setting (4) IP 192.168.90.12 GW 192.168.90.1 Setting for connected devices * Set the IP address for the default gateway of V9 2 setting. -6- Copyright 2014 All Rights Reserved.

Realize the implementation of solution with lower cost!! Please experience the solution with FREE license (30 days)!! Office Factory Simple configuration V-Connect (Management tool) tunnel ( server) tunnel PC Remote access V9 series <Requirement tools and cost> <Initial cost> (1) Management tool V-Connect FREE (2) V9 series <Running cost> (1) The cost for internet connection in the office If there is connection in the office: FREE (2) The cost for internet connection in the factory If there is connection in the factory: FREE (3) The cost for remote access license There are several plans depending on the needs (Annual renewal fee is required). -7- Copyright 2014 All Rights Reserved.

Local IP connection All the devices are possible to be accessed by the local IP from a remote location. Connection with local IP is possible!! 192.168.150.110 Ladder tool 192.168.150.100 VNC client Global IP is NOT required! V-Connect (Management tool) Firewall Firewall PC virtual tunnel ( server) Remote access tunnel V9 192.168.150.100 192.168.150.110 PC 192.168.150.10 V9 192.168.150.100 192.168.150.110-8- Copyright 2014 All Rights Reserved.

Connection is anytime and anywhere!! Due to SSL-, it is possible to connect V9 from anywhere if there is the internet connection. Remote access by IP-Sec Remote access by V9 (SSL-) Internet ( server) Hotel Airport router router Display Router is required * Remote access was unavailable from your house or when you are on business tip. * IT knowledge is needed compared with SSL-. V9 Special device is not needed! ( router) It is possible to remote access from your house or even when you are on business trip!! * It is possible to access whenever you have the internet connection. * Advanced skill is not required. -9- Copyright 2014 All Rights Reserved.

No need to consider the firewall No issue for firewall with HTTPS protocol by using SSL-. IP-Sec It is necessary to change the firewall setting and open the port of TCP No.51 and No.50. V9 (SSL-) Normally TCP port No.443 is opened on firewall to connect to the internet from the office. It is not necessary to change the setting because V9 uses SSL-. *1 Internet HTTPS is used when the security service is required on the website. Internet banking Searching Reservation router Shut Port 443 (HTTPS) * There may be a block by the firewall in the public environment. * It is necessary to open the several ports on firewall. Pass ( server) * It is possible to pass through the firewall whenever there is the internet connection. *1: There may be set to shut the session with the specific time depending on the customer. In this case, please open this port always. -10- Copyright 2014 All Rights Reserved.

Remote access to various devices It is possible to access to the devices which are connected to V9 remotely by using the routing function*1. V-Connect (Management tool) Ladder tool VNC client Network camera software tunnel ( server) tunnel What can you do to V9 series? * Remote access (VNC client) * Download screen program (V-SFT-6) * FTP access (FTP client tool) *1 only with 2ch model Network camera -11- Copyright 2014 All Rights Reserved.

Configuration example (1) (Connection for WAN) Various choice of connection configuration depending on your needs!! When the company s network is used: (Wired ) The cheapest system configuration of remote access: Wireless type only When the company s network is used: (Wireless ) The network establishment is not required and not need to pay for internet connection. ( server) ( server) Access point Wireless type only When mobile internet router is used: (Wired ) Even if it is difficult to make the network connection on the machine or system for, it is possible to remote the site remotely by using mobile router *1 (LTE/3G). When mobile internet router is used: (Wireless ) Although the network fee for the mobile router is needed, but the network establishment is not required. ( server) ( server) Mobile router for data communication (Wired type) Mobile router for data communication *1:Wired port is needed. -12- Copyright 2014 All Rights Reserved.

Configuration example (2) System configurations below are possible. 1:1 connection 1:n connection Connect one PC to monitor and one V9. Connect one PC to monitor and multiple V9s. ( server) ( server) 1:n:m connection 2ch type only Connect one PC to monitor and multiple V9s which have multiple devices connected on their second ports. n:n connection Charged license only Connect multiple PCs to monitor and multiple V9s. ( server) ( server) HMI -13- Copyright 2014 All Rights Reserved.

How to set up on V9 setting on V9 local screen. < setting (Current operation in July) Register all the necessary information on V9 to link the information of PC and V9 series. <Proxy setting> Set the information when it is connected to internet via the proxy server. Select the Ethernet port used for connection. Input domain, node and password according to the information which is sent from Hakko after applying the application form. Input the information of Proxy server. -14- Copyright 2014 All Rights Reserved.

V-Connect (Management tool) Install the management tool on the PC which you use for remote monitoring and connect to server. Log in screen When V-Connect is stated up, the log in menu is displayed. Input Domain name on the application form. Input these information which you receive from Hakko after applying the license. Input the proxy information when it is used. Main screen Logged in The information which is registered on the server is displayed according to the long in information. Select the connecting devices (e.g.=demodomain1) and click Connect. V9 information is displayed which is registered on server. It is possible to confirm the connection status of server. Connection status of V9 :Connecting to server :Not connecting to server -15- Copyright 2014 All Rights Reserved.

Easy connection between monitoring site and devices in the factory with domain ID and node ID How do we establish the connection with your multiple V9s? e.g.)domain name: HAKKO Domain and node ID hand shake on the server Node ID: HAKKO-01-16- Copyright 2014 All Rights Reserved.

Application example 1 Preventive maintenance (condition based maintenance) Remote maintenance system enables systematic maintenance of the equipment by monitoring the operation status and checking for signs of abnormality. Appropriate maintenance can extend the machine s lifespan and reduce the frequency of accidental stoppages. -17- Copyright 2014 All Rights Reserved.

Application example 2 Improvement of the service It is possible to collect the system information from the each factory by monitoring remotely. It can help you to make the priority for the visiting the customers. Operation time -18- Copyright 2014 All Rights Reserved.

Model Type Advanced Model V9101iWRLD Display size/resolution Touch switch Video/ RGB AUDIO output Wirele ss Specifications Extend ed UL508 ANSI ISA Capacitance Yes Yes Yes Yes Yes No Yes Yes CE KC Power supply connection V9100iWRLD Yes Yes Yes Yes Yes No Yes Yes Yes Yes 10.1 wide 1024x600 DC24V V9101iWLD Capacitance Yes Yes No Yes Yes No Yes Yes Yes Yes V9100iWLD Yes Routing Yes Yes No Yes Yes No Yes Yes Yes Yes Yes Production type Standard Product produced on order item Standard Product produced on order item Type Model Display size/resolution Touch switch Video/ RGB AUDIO output Wirele ss Specifications Extend ed UL508 ANSI ISA CE KC Power supply connection Routing Production type Standard V9100iS V9100iSD V9100iSLD V9100iSRD V9080iSD V9080iSLD V9080iSRD 10.4 800x600 8.4 800x600 Yes Yes No No No No No Yes AC100 to 240V Yes No Yes Yes No No Yes # Yes Yes Yes Yes No Yes Yes No Yes Yes DC24V Yes Yes Yes Yes Yes No Yes No No No Yes Yes Yes Yes No No Yes # Yes Yes Yes Yes No Yes Yes No Yes Yes DC24V Yes Yes Yes Yes Yes No Yes No No No Yes Yes Yes Yes No No Standard Product Standard Product produced on order item produced on order item Standard Product produced on order item produced on order item Type Lite Model V9100iC V9100iCD Display size/resolution 10.4 640x480 V9080iCD 8.4 640x480 Touch switch Video/ RGB AUDIO output Wirele ss Specifications Extend ed UL508-19- Copyright 2014 All Rights Reserved. ANSI ISA CE KC Power supply connection Routing No No No No No No No Yes AC100 to 240V Yes No No No No No Yes No Yes Yes DC24V Yes No No No No No Yes No Yes Yes DC24V Yes No #: ANSI ISA/NEMA4 will be supported after the release. Production type Standard Product Standard Product Standard Product

License Types We provide you various kinds of license depending on your needs. Type Free Value Simple Wide Extra System Configuration (see below) 1:1 OK OK OK OK OK 1:n OK OK OK OK OK 1:n:m OK OK OK OK OK n:n - OK OK OK OK V9 stations (max) 5 10 30 100 Unlimited Part Number Additional connection *1 - -A 1st Year - -V -S -W -E Renewal (annual) - -VR -SR -WR -ER Notes 30 days (To be deactivated if paid license is not registered within the period.) *1 Registered V9 panels are usually connected as a same network when connection is established. If you wish to use particular V9 panel(s) as different network, you need additional connection (subdomain) as many as necessary. -20- Copyright 2014 All Rights Reserved.

Registration process for Customer (Process by Oct, 2014) Step2 Step1 Apply for Free license Step3 Step4 Download the Management tool (V-Connect) Step2 V9 connection PC connection Apply for Charged license STEP1 STEP2 STEP3 STEP4 Download the management tool (V-Connect) - Users download the management tool from our website for free. Apply for Free license Download the application form from our website. Fill out all the information on the sheet and contact with the sales office. Apply for Charged license Download the application form from our website when you apply for free license or switch it to the charged license. Fill out all the information on the sheet and contact with the sales office. V9 connection (1) Set up the (IP) setting (Internet connection setting) on V9 local screen. (2) Set Connection ID/Node ID/Password and connect to server. (Set up the proxy setting when it is required.) PC connection Select the MONITOUCH which you wish to connect from the management tool (V-Connect) then establish the connection. *Download V-Connect and application form from: URL:http://monitouch.fujielectric.com/site/support-e/download-index-01.html -21- Copyright 2014 All Rights Reserved.