Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission



Similar documents
A BIG STEP IN REDUCING YOUR CARBON FOOTPRINT.

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

Aludesign K A T A L O G

NEW. Conventional gas fired boilers open vented / sealed unvented. > 94% (Hi) CGU-2 / CGU-2K CGG-2 / CGG-2K

Working towards a cleaner future. 30 to 4000kW. Condensing Aluminium 30 to 600kW. Condensing Stainless Steel 50 to 160kW

User's Instructions. Alpha HE CB25/33 and HE SY25

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

PART 11: START-UP PROCEDURES FOR THE INSTALLER

For installation guide see reverse of book

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Worcester GB162 wall mounted gas-fired condensing boiler series

Remeha P 200. Technical information. Pressurized boiler. Heat output: kw

Luna 3 Comfort Troubleshooting Guide June 2008

ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS kw FS kw FS kw FS kw FS kw

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Refrigeration Compressed Air Dryer Buran Ultrapulse

NAVIEN AMERICA INC FITCH AVENUE

ECOCIAT. Domestic hot water heat recovery unit

UDSA - UDSBD unit heater

United Kingdom en. ErP information. Gas fired condensing boiler Gas 210 ECO PRO

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Spare Parts List M96A.24SM/B M96A.28SM/B

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Electric Flow Boiler

Operating instructions

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Commercial Gas Water Heater

Installation and Servicing Instructions

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Gas Atmospheric Boilers

User manual and Installation instructions

High Efficiency Boiler Range Technical Guide

ETHOS WALL MOUNTED CONDENSING BOILERS

TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/ kw GS20D 58/ kw

Drayton Digistat +2RF/+3RF

The Best Selling Domestic Stainless Steel Oil Boiler

Operating instructions

LMS The modular management system for condensing boilers. Control Products & Systems OEM. Answers for infrastructure.

Apartment and Communal Heating Solutions

HEAVY DUTY STORAGE GAS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

GRANT. Vortex Condensing Oil Boilers. USER, INSTALLATION and SERVICING INSTRUCTIONS

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

GAS HEATING IN COMMERCIAL PREMISES

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Rapid 25 Rapid 32. Installation Manual. Intergas Heating Ltd.

Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.

DKG 972 Gas Burner Safety Control

BFC. High Efficient Condensing Water Heater BFC - 28/30/50/60/80/100/120. Installation, User and Service Manual. Innovation has a name.


Baxi Combi 80e & 105e

AMBASSADOR (KITCHEN), COUNTRYMAN (OUTDOOR) & CONSUL (BOILERHOUSE) CONSENSING BOILERS SENATOR (KITCHEN) & COUNTRYMAN (OUTDOOR) COMBI CONSENSING BOILERS

Mikrofill Ethos Condensing combination boiler

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

The Concept of Condensing Boilers

Alpha CD13R,18R and 24R

Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

The natural ombination

Heating and Hot Water Services Controls General Technical Specification

Daikin Altherma hybrid heat pump. The natural combination

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Verve. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

ELECTRIC CENTRAL HEATING FLOW BOILER

Operating instructions

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Smile. The All-In-One Heating Controller

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Oil - kerosene burners

Session 2: Hot Water Supply

Daikin Altherma Hybrid Heat Pump

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

TWO STAGE GAS BURNERS

HERZ-Thermal Actuators

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Daikin Altherma Hybrid Heat Pump

Excel. High efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. Excel 25 G.C. N Excel 29 G.C.

MODULATING LIGHT OIL BURNERS RL/M SERIES

Mynute 25 A. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Commercial Gas Furnace Upflow

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

solaris 24PC 30PC Pre-Mix Condensing Combination Boiler

Heating Controller. Building Technologies HVAC Products

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Response: The combi boiler. Response: The fit anywhere combi

Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Alpha InTec 30GS and 40GS

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

york air-conditioning products Residential & VRF News 2015

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Transcription:

Quinta Range Condensing Boilers REMEHA QUINTA RANGE High efficiency wall hung condensing boiler with ultra low NOx emission QUINTA RANGE OUTPUTS Q30: 5.6-28 kw Q45: 7-40 kw Q65: 11-61 kw Q85: 14.4-84.2 kw Q115: 18-115 kw SEDBUK A (Q30, Q45, Q65)

Introduction Remeha Quinta Range are compact wall hung condensing boilers. Lighter and more efficient, their small dimensions make them ideally suited for modular arrangements. An optional optimising/ weather compensating control system is available to ensure maximum efficiency. The boilers can be installed on both new and retrofit installations. Contents page Introduction 2 Boiler description 2 Typical boiler construction 3 Efficiency Information 3 Advantages at a glance 4 Operating principle 4 Dimensions 4 Technical data 5 Typical Installation 6 Typical flue systems 7-8 Electrical installations and controls 9-11 Boiler description The Remeha Quinta Range are wall hung, condensing boilers which may also be installed free standing on a suitable frame (option). The one piece, cast aluminium heat exchanger and other major components are contained within a sealed air box. This forms the main boiler casing with a removable front section for maintenance purposes. All electrical and electronic controls are contained within the instrument panel mounted behind the drop-down lower front panel. The combined flue gas outlet and combustion air inlet are mounted on the top of the boiler, with the flow, return, gas and condensate connections located at the bottom. The boiler is suitable for room-sealed or open flue applications. It has been designed for central heating and indirect hot water production. It must be installed on a fully pumped system and is suitable for use on both sealed and open vented installations (minimum operating pressure of 0.3 bar open vented and 0.8 bar pressurised. The pre-mix, down-firing gas burner (NG or LPG) with its gas/air ratio control system, ensures clean, trouble free operation with higher than average efficiencies (of 110% (NCV)) in the condensing mode, combined with ultra low NOx and minimum CO emissions. The standard control package allows actual and set values to be read and adjusted on the built-in digital display which also provides normal operating and fault code indication. An intelligent, advanced boiler control (abc) continuously monitors the boiler conditions, varying the heat output to suit the system load. The control is able to react to external negative influences in the rest of the system (flow rates and air/gas supply problems) maintaining boiler output for as long as possible without resorting to a lock out condition. At worst the boiler will reduce its output and/or shut down (shut-off mode); awaiting the negative conditions to return to normal before re-starting. The abc control cannot override the standard flame safety controls. The boiler meets the requirements of the EC regulations and directives: - 90/396EEC Gas appliances directive - 92/42/EEC Efficiency directive - 73/23/EEC Electrical low voltage directive - 89/336/EEC E.M.C. directive CE Certification Remeha Quinta 30 - PIN: 0063BM3043 45/65/85/115 - PIN: 0063BL3253 2

Typical boiler construction 1. Automatic air vent 2. Air supply fan 3. Gas combi-block (with governor) 4. Gas injector/venturi (not shown) 5. Cast aluminium heat exchanger 6. Temperature sensor - return 7. Air inlet tube 8. Pressure gauge (not shown) 9. Control panel 10. Facility for incorporating a rematic weather compensated boiler control 11. Heat exchanger inspection cover 12. Sight glass 13. Combined ignition/ionisation probe 13 12 11 2 6 15 5 3 7 1 REMEHA QUINTA RANGE 14. Temperature sensor - flow (not shown) 10 9 15. Pre-mix burner Efficiency information Annual efficiency Up to 109% at Hi (98% at Hs) at an input of 30% and a return temperature of 30 C. Heat to water efficiency a. Up to 99% at Hi (89% at Hs) at an average water temperature of 70 C (80/60ºC) - Quinta 30, 45 & 65. b. Up to 98% at Hi at an average water temperature of 70 C (80/60ºC) - Quinta 85 & 115. c. Up to 110% at Hi (99% at Hs) at an average water temperature of 35 C (40/30ºC) - Quinta 30, 45 & 65. d. Up to 106% at Hi at an average water temperature of 35 C (40/30ºC) - Quinta 85 & 115. Note: NCV = Hi, GCV = Hs Application information The Quinta Range can be used on all new and refurbishment projects in both single and multiple configurations. Conventional and room-sealed flue system capability means that the boiler can be sited almost anywhere within a building. The Remeha weather compensators (options) are able to communicate directly with the boiler controls (two wire) to make full use of its fully modulating feature, ensuring that the boiler closely matches the system demand at all times. External control systems (BMS) can be interfaced with the boiler to provide on/off, high/low or modulating (0-10v) control options. Quinta 45/65 illustrated The wall hung Quinta from Remeha. More power in a smaller space. 3

Advantages at a glance High efficiency: 110% NCV at 40/30ºC (99% GCV) Boiler control: a) Modulating (18-100%) b) High/low (18-100%) c) On/off Premix burner for clean combustion Low NOx < 25ppm (02=0%, dry) Quiet operation <48 dba Digital display Data file for storing information Remote signalling options Cast aluminium heat exchanger Easy maintenance Built-in calorifier control Options for modular control and/ or weather compensator Control 0-10V signal or volt free PC connection Advanced boiler control, Remeha s abc, for reliable heat delivery Conventional or roomsealed operation Cascade packages for up to 6 boilers Quick and easy installation Space saving For use with natural gas and L.P.G. (Some models require a conversion kit) Operating principle Combustion air is drawn into the closed air box, by a variable speed fan, through the air inlet connection from the plant room (open flued) or from outside via the concentric flue system (room-sealed). On the inlet side of the fan is a specially designed venturi which is connected to the outlet side of the gas combi block. Depending on the demand (under the dictates of flow/return sensor and other external/internal control inputs) the electronic control unit directly monitors the volume of gas and air being delivered to the premix burner. This mixture is initially ignited by the combined ignition/ionisation probe which then monitors the state of the flame. Should the flame not ignite or be unstable, within the pre-set safety time cycle, the controls will shut the boiler down (after 5 attempts) requiring manual intervention to reset the boiler. The digital display will also indicate a flashing fault code confirming the reason for the failure. 'A' Dimensions Quinta 30 Return connection ø 22 mm o/d Second flow connection ø 22 mm o/d (optional for DHW production with 3-way valve Flow connection ø 22 mm o/d Gas connection ø 15 mm o/d Condensate connection 25 mm o/d (plastic) Combustion air supply connection ø 125 mm i/d Flue gas connection ø 80 mm i/d Holes for mounting bracket Air vent discharge Dimension 'A' Quinta 45 65 = 360 Quinta 85/115 = 452 Quinta 45/65/85/115 Flow connection 1 1 /4" BSP (m) & 1" BSP (f) Return connection 1 1 /4" BSP (m) & 1" BSP (f) Gas connection 3 /4" BSP (m) Condensate connection 25 mm o/d (plastic) Flue gas connection 80 mm i/d (Quinta 45) and 100 i/d (Quinta 65/85/115) Combustion air supply connection 125mm (Quinta 45) and 150 i/d (Quinta 65/85/115) Holes for mounting bracket 4

Technical data Boiler type Quinta 30 Quinta 45 Quinta 65 Quinta 85 Quinta 115 General Casing colour BS RAL 9016 Boiler control options (External input) On/off, High/low, Analog 0-10V (Two wire control) Communicating Modulation Nominal output (80/60ºC) kw 5.6-28.0 8.0 40.0 12.0 61.0 14.1-84.2 16.6-107 Nominal output (40/30ºC) kw 5.9-29.6 8.9 43.0 13.3 65.0 15.8-89.5 18.4-114 Nominal input (GCV / Hs) kw 6.3-31.6 9.1 45.7 13.6 68.8 16.2-95.3 19.1-123.2 Nominal input (NCV / Hi) kw 5.7-28.5 8.2 41.2 12.2 62.0 14.7-86.0 17.2-111 Weight dry kg 43 57 64 72 74 Noise level at 1M from boiler dba <44 <48 <52.5 Gas and flue details Min/max Inlet pressure natural gas mbar 15-50 17 30 17 30 17-30 17-30 Min/max Inlet pressure propane mbar 37-50 37-50 37-50 37-50 37-50 Gas consumption (natural gas) m 3 /h 0.6-3.2 1.0 5.0 1.5 7.5 1.5-9.1 1.8-11.7 Gas consumption (propane) m 3 /h 0.3-1.2 0.3-1.7 0.5-2.5 0.6-3.3 0.66-4.25 NOx emission (expected seasonal) mg/kwh <39 Residual fan duty Pa 100 150 100 160 220 Mass flue rate kg/h 10-48 14-69 21-104 23-138 29-187 Water side Flow temperature maximum ºC 100 (110) Flow temperature operating ºC 20-90 Operating pressure min open vented bar 0.3 min pressurised bar 0.8 max bar 3.0 3.5 4.0 Water contents ltr 3.1 5.5 6.5 7.5 7.5 Water resistance at 11 C t mbar 460 300 430 460 826 Water resistance at 20 C t mbar 140 90 130 140 250 Electrical Main supply V/Hz 230 / 1 / 50 Electric rating W 46 30-85 30 90 30-160 40-240 Insulation class IP 20 20 20 20 20 REMEHA QUINTA RANGE The products of combustion in the form of hot flue gases are forced through the heat exchanger, transferring their heat to the system water (the flue gas temperature is reduced to approximately 5 C above the temperature of the system return water) then discharged via the condensate collector, vertically through the 80/125 mm (Quinta 30/45) or 100/150 mm (Quinta 65/85/115) combined flue/air connection to atmosphere. Because of the low flue gas exit temperature there will be a vapour cloud formed at the flue gas terminal this is not smoke, simply water vapour formed during the combustion process. If the controls allow the flow and therefore return temperature to fall below dew point (55 C) this water vapour will begin to condense out in the boiler transferring it s latent heat into the system water, increasing the output of the boiler without increasing gas consumption. Condensation formed within the boiler and flue system is discharged from the boiler to an external drain via the drain pan/siphon supplied. 5

Typical installation Showing Quinta 45/65/85/115 (Quinta 30 flow and return connection are reversed) Single boiler Single boiler with low loss header With DHW-Remeha priority - Quinta 45/65 For Quinta 85/115 use a DHW primary pump Multiboiler 6

Multiboiler with low loss header (open tube site fabricated) Based on 80 c/60 c Flow Boiler side 20 ΔT/System Side 11 ΔT Quinta 30/45 Quinta 65/85 Quinta 115 No. of Boilers 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 Low Loss Header Dia mm 100 125 150 150 200 150 200 225 250 250 150 200 250 250 300 Connecting Pipework A mm 42 42 50 50 50 50 65 80 80 100 50 65 80 100 100 Connecting Pipework B mm 50 50 65 80 80 65 80 100 125 125 80 100 125 125 125 Dimension "A" mm 300 375 450 450 600 450 600 675 750 750 450 600 750 750 900 Dimension "B" mm 350 425 500 500 650 500 650 725 800 800 500 650 800 800 950 REMEHA QUINTA RANGE Typical flue systems Concentric room-sealed applications VRS roof mounted room-sealed terminal Quinta 65/85/115 100/150 System Quinta 30/45 80/125 System Calculation data room-sealed applications Quinta 30 Quinta 45 Quinta 65 Quinta 85 Quinta 115 80/125mm 80/125mm 100/150mm 100/150mm 100/150mm max eq. length m 20 16 13 13 7 eq. length bend 45 m 1.2 1 1 1 2 eq. length bend 90 m 4 2 2 2 3 7

Conventional flue Bird guard and reduction cone Calculation data conventional flue Quinta 30 Quinta 45 Quinta 65 Quinta 85 Quinta 115 80mm 80mm 100mm 100mm 100mm max eq. length m 40 33 27 24 19 eq. length bend 45 m 1.2 1.2 1.4 1.4 1.4 eq. length bend 90 m 4 4 4.9 4.9 4.9 CLV system (twin pipe - two zone) Bird guard and reduction cone Bird guard Calculation data different pressure zones Quinta 30 Quinta 45 Quinta 65 Quinta 85 Quinta 115 80mm 80mm 100mm 110mm 125mm max eq. length m 20 28 18 22 58 eq. length bend 45 m 1.2 1.2 1.4 1.5 1 eq. length bend 90 m 4 4 4.9 5.4 1.7 For further options see flue booklet. - Please note that the maximum flue length is calculated on the flue diameter stated. Flue lengths will be increased using larger diameter flue pipe. - Please contact our technical department for assistance if required. 8

Electrical installation and controls General The Remeha Quinta Range is supplied as standard with electronic control and flame ionisation safety controls, with a specially designed microprocessor at the heart of the control system. Specifications Electrical supply The Remeha Quinta Range must have a permanent 230V-50Hz single phase supply rated at 6.3 amps. The control unit is not phase /neutral sensitive. Control box Manufacture: Gasmodul Model: MCBA 1461 D Supply voltage: 230 V/50 Hz Electrical rating: 10 VA Pre-purge time: 0.3 seconds Post-purge time: 10 seconds Safety time: 3 seconds Anti-hunting time: 150 seconds Pump run on (HTG): 1-15 minutes Pump run on (DHW): 5 minutes Fuse specification The boiler is protected by fuses: - on the main power supply located in the euro connector socket rated at 6.3 amps (slow acting). - control circuit 230 volt, 2 amps (fast acting). - control circuit 24 volt d.c., 4 amps (slow acting). Boiler temperature control The Remeha Quinta Range has electronic temperature control with flow and return temperature sensors. The flow temperature can be adjusted between 20 and 90 C. Low water protection (flow and content) The Remeha Quinta Range are supplied with a low water protection on the basis of temperature measurement. By modulating back at the moment that the water flow threatens to fall too low, the boiler is kept operating for as long as possible. In the event of low flow (F/R t > 45 C) the boiler will shut off and not lockout. If the boiler is fired dry it will go to lockout (code 18). External connections All external connections (except rematic 2945 C3) are made on the 24 way terminal strip, located in the instrument box at the bottom of the boiler. Boiler run volt free (closes on run) Common alarm volt free (opens on failure) Boiler pump or system pump (max. 1Amp) DHW diverting valve or primary pump 230V signal to BMS power supply live External interlock - volt free DHW sensor or volt free thermostat High / low (2nd stage) or outdoor sensor ON / OFF (1st stage) 0-10V or modulating controller REMEHA QUINTA RANGE High limit temperature protection The high limit, temperature protection device switches off and locks out the boiler when the flow temperature exceeds the high limit set point (adjustable). When the fault is corrected the boiler can be restarted by using the reset key on the control panel. 9

Boiler control The Remeha Quinta Range can be controlled using one of the following methods Modulating (two wire control) When using the optional Remeha compensating controllers the heat output modulates between the minimum and maximum value on the basis of the boiler flow temperature sensor. This applies to both single and multiple boiler installations, under the dictates of a room and/or outside temperature sensor. Celcia 20 - Optimising room/outside weather compensating control for single boiler. Control is supplied as standard for room compensation. For outside weather compensation the optional o/s sensor must be installed and connected. Control communicating with the boiler directly via two wire interface. Celcia MC4 - In conjunction with Celcia 20 can provide step control for multi boiler installation of up to four boilers. Analog control (0-10 volt d.c.) The heat output modulates between the minimum and the maximum values on the basis of the voltage supplied by an external analog (0-10V) input. - Temperature based (20 to 90 C). To set the ratio between voltage and the desired flow temperature, see the graph below. - Output based - fixed parameters (18 to 100%), see the graph below. 0 volt = boiler off 0.5-1.8 volt = heat input 18% 1.8 volt - 10 volt = boiler modulates between 18 and 100% on demand. On/off control (1 x no volt switched pair) The heat output modulates between the minimum and the maximum value based on the set flow temperature. High/low control (2 x no volt switched pairs) The heat output is controlled between part load (18% adjustable) and full load, by means of a two-stage controller. 10

Priority DHW control Temperature control With a Remeha temperature sensor or with a standard (volt free) DHW thermostat. Note: will only provide a setting and read out facility with the sensor option. Primary flow control - With a three-way diverting valve. (Not Q85/115) - With a DHW pump. - Untimed (available 24 hours a day). System pump A system pump can be connected to the boiler (230-1-50 max. 1 amp). If the system pump requires more than 1 amp, terminals can only be used to switch a pump relay. System water Before operation the system should be flushed and filled with mains cold water. As the heat exchanger is aluminium, if water treatment is considered a max. ph level of 8.5 MUST NOT BE EXCEEDED. Remeha recommended treatments are - Sentinal X-100 or Fernox F1. Frost protection Install the boiler in a frost-free room. The builtin frost protection system is activated as follows: Below 7 C - system pump is switched on if connected to boiler. Below 3 C - boiler is switched on, when the flow temp reaches 10 C the boiler and pump switch off. NOTE: This control is designed to protect the boiler - for full system protection use a frost themostat or a weather compensator. Remote alarm and boiler run indication As standard the boiler is supplied with 2 x volt free indicators - Common alarm signal (opens on alarm) and boiler run signal (closes on Boiler run). Maximum 230 volts, 1amp capacity each. Safety interlock As standard the boiler is supplied with an interlock carrying a 24 volt boiler control circuit. REMEHA QUINTA RANGE 11

The data published in this technical sales leaflet is based on the latest information (at date of publication) and may be subject to revisions. It should be read in conjunction with our full technical brochure (available on request). We reserve the right to continuous development in both design and manufacture, therefore any changes to the technology employed may not be retrospective, nor may we be obliged to adjust earlier supplies accordingly. Issue 6 date: 20/07/09 Broag Ltd. Head Office Remeha House Molly Millars Lane Wokingham Berkshire RG41 2QP T: 0118 978 3434 F: 0118 978 6977 E: boilers@broag-remeha.com www.remeha.co.uk Remeha is committed to carbon offsetting Designed and produced by Sans Frontiere Marketing Communications 01273 487 800 www.sansfrontiere.co.uk