Transforming know-how into solutions. Siemens Transformer Service TLM



Similar documents
Siemens TMDS transformer monitoring and diagnostic system. Solutions for transformer life-cycle management. Answers for energy.

Transformer Fleet Management with e-terraassetcare

Alstom Grid Services. Transformer lifecycle management GRID

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

DGA - Method in the Past and for the Future

On-line monitoring of substation condition a Romanian experience. V. ZAHARESCU, Vl. ROSCA Nova Industrial SA. CN Transelectrica SA Romania

GE Energy Transformer Monitoring: How Moving forward from Monitoring to Diagnostics can Positively Impact Indian Business and Industry

SMART ASSET MANAGEMENT MAXIMISE VALUE AND RELIABILITY

TMDS Smart Monitor. Solutions for transformer life-cycle management. Answers for energy.

ABB Brasil. Power Transformers: Life Cycle and Operational Cost Optimization From Purchase to Minimum Maintenance

Monitoring and diagnostics

Electrical Maintenance Workshop

Intelligent maintenance decisions with ABB TrafoAssetManagement TM proactive services

Smart Asset Management

Distribution Voltage Regulators

THE VALUE OF POWER FACTOR TESTING

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Monitoring, Diagnostics, or Changing Condition?

Substation Automation and Smart Grid

Technical Electrical Field Service Support. Knowledge + Experience = Power. Field Service

HI TECH TRANSFORMER MAINTENANCE (PTY) LTD. COMPANY PROFILE AND OVERVIEW 19 March 2012

Practical Transformers: Operation, Maintenance and Testing

OMICRON Monitoring Solutions

Hydro Plant Risk Assessment Guide

TRANSFORMERS AFTERMARKET SPARES, SERVICE & REPAIR

On-line PD Monitoring Makes Good Business Sense

THE OLTC AS AN "OIL ISOLATED SYSTEM" IN THE TRANSFORMER & OIL ANALYSIS IN OLTC. I Hr. Dr. Hurm, Hr. Dr. Schübel I I

Power transformers. Phase shifting transformers Reliable and efficient power flow control

Dissolved Gas Analysis Guide for Transformers Filled with Beta Fluid

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

Energy Transmission and Distribution Services

Step Voltage Regulators

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

The On-Load Tap-Changer for Maximum Switching Frequency More Switching Operations without Needing Maintenance.

A Step-Up Transformer Online Monitoring Experience at Euzébio Rocha UTE [Thermal Power Plant]

Turbo generators Best quality for thermal power plants

Transformers: Basics, Maintenance, and Diagnostics

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

Power Transformers Small, Medium & Large

This section applies to the design and installation of transformers.

CONNECTING YOU TO SPECIALIST ELECTRICAL SUPPORT services

Dry-type transformers. Dry-type transformers from ABB The ideal solution for the oil and gas industry

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

Houston Service Center Medium Voltage Service and Aftermarket Solutions

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Electrical Predictive and Preventative Maintenance

TAN δ (DELTA) CABLE TESTING OVERVIEW AND ANSWERS TO FREQUENTLY ASKED QUESTIONS. What Is Tan δ, Or Tan Delta?

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Presentation of the France Transfo factories

Primary and Secondary Electrical Distribution Systems

Drives and motors. A guide to using variable-speed drives and motors in data centres

electrical services

Smart solutions for fleets of all types & sizes of power generation. Marcus König, E F IE SGS / September 2013

Minimizing Impact of Electric Utility Outages with Backup Generation

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

ABB PSPS Erich Steinmann; Generator control-2013

ESCOM BY G.KALINDE SUBSTATIONS ENGINEER

Engineering & Support Services

Transformer Thermal Overload Protection - What s It All About?

Power transformers. Special transformers Railway

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

ARC VIEW. Emerson Asset Optimization Business Breaks New Ground. Summary. A Business of Vital Strategic Importance.

ASSESSMENT OF OIL ANALYSIS DATA FOR MEDIUM VOLTAGE DISTRIBUTION TRANSFORMERS

Attachment SA Power Networks: Asset Management Plan Substation Transformers 2014 to 2025

Achieving Operational Efficiencies through On-Line Substation Monitoring. Vince Polsoni Powerstream Inc. Manager Station Sustainment EDIST 2016

RCP2 Portfolio Overview Document

Siemens Answers for DoD Installations

Assessing, Maintaining & Replacing Fluid Filled Cable Systems at PEPCO

Root-Cause Analysis of Transformer Failure Scenario at Power Sub-Station

Transformers. Special transformers Reactors products

OPTIMIZE YOUR FLEET MANAGEMENT RESOURCES

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Testing of Power Transformers. Routine tests, Type tests and Special tests

Perception Fleet. GE Digital Energy. Smart Management System. Transformer Fleet Risk Management Software System. Simple Diagnostics.

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

Power Transmission and Distribution. Shunt reactors for medium and highvoltage. From development to use

On-line Condition Monitoring and Diagnosis for Power Transformers their Bushings, Tap Changer and Insulation System

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

Monitoring the Operation of Wind Turbines Alex Robertson, Vestas Northern Europe

AMSC s Superconductor Cable Technologies for Electric Utilities

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

ON-LINE MONITORING OF POWER PLANTS

Energy Saving Fact Sheet Boilers

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

Tamini is the leading Italian company in the world for the design and production of industrial, power and special transformers.


Monitoring, diagnostics, and cable services

Perception Fleet. GE Digital Energy. Transformer Fleet Risk Management Software System. Smart Management System. Simple Diagnostics.

High Voltage Electrical Equipment Failure Diagnosis. Presented by: Spencer Tang & Terence Ng T&T Inspection & Engineering Sdn Bhd

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

AORC Technical meeting 2014

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

Transcription:

Transforming know-how into solutions. Siemens Transformer Service TLM

TLM Agenda Introduction Instalation and Comissioning Condition Assessment Monitoring Repairs and Retrofit Spare Parts - Solutions After Sales and Training Page 2

TRANSFORMERS STRUCTURE Page 3

TLM WORLD STRUCTURE Page 4

Vision / Mission Page 5

Why TLM is strategic? Legacy transformers Landscape Number of Explosions 5 4 3 250 200 150 100 50 0 Average age of US transformers: 39 years 1951 1971 Exponential growth of explosion occurrences 1977 1979 1980 1981 1982 1983 1984 1985 1986 1987 1988 1989 Sergi Transformer Explosions in the United States along with the end of life Year 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2 1 0 1973 1978 1983 1988 1993 1998 2003 2008 2013 William H. Bartley P.E., Hartford Steam Boiler Inspection & Insurance Co., "Life Cycle Management of Utility Transformer Assets," Page 6

Brazilian Legacy transformers Landscape Average age of Brazilian transformers: ~29 years Legacy Transformers Age - Brazil 25,00% 20,00% ~65% of legacy transformers 20,80% 16,20% 15,00% 11,90% 10,00% 9,50% 9,20% 10% 5,00% 5,50% 5,70% 6,30% 5% 0,00% 0...5 years 6...10 years 11...15 years 16...20 years 21...25 years 26...30 years 31...35 years 36...40 years 41...45 years >46 years Page 7

Transformer Rate Failure Fonte: William H. Bartley - International Association of Engineering Insurers 36th Annual Conference Stockholm, 2003. Page 8

TLM@siemens.com solutions for power transformers of any brand and any age - Portfolio Transport Installation & Commissioning Disassembly, Preparation for Transport, Shipping & Transport Management, Installation & Commissioning Condition Analysis & On-Site Diagnostics Oil Laboratory Services, Condition Assessment, Fleet Screening, Lifecycle Assessment, Advanced Electrical Measurement, H-V Tests On-Site Lifecycle Maintenance Preventive, curative corrective Maintenance, Long-Term Maintenance, Online Drying & Degassing, Active Part Drying, Oil Regeneration, End of Life Management, Scrapping On-line Monitoring Measuring Sensors, Gasguard, Tapguard, Single Transformer Comprehensive Monitor, Integrated Substation & Central Server Monitoring Troubleshooting Repair & Retrofit Failure Diagnostics, Repair on-site, Repair & Modifications in-house, Refurbishment, Retrofit, Modernization, Up-grading Spare Parts Accessories Bushings, Tap-Changer Motor Drives & Contacts, Coolers, Fans & Pum ps, Protection Devices & Relays, Consulting Expertise Training Engineering Service, Advice & Recommendations for preventive, corrective and curative actions, Educational Seminars and Workshops Page 9

TLM Organization Chart - Brazil TLM BRASIL - ORGANIZATION CHART TLM BERNARDO SALUM SALES AND COORDINATION - TLM MONITORING CONSULTANT MONITORING AFTER SALES - PT AFTER SALES - DT FIELD SERVICE Ademir Santana José Geraldo -- ---- -- David Scaquetti Mauro Mathiazi Andre Rosendo MAURICIO IRAHA REPAIR ENGINEERING WILTON A. FA RIAS FIL HO REPAIR WORKSHOP IVAN GAZZI Page 10

TLM Agenda Introduction Instalation and Comissioning Condition Assessment Monitoring Repair and Retrofit Spare Parts - Solutions After Sales and Training Page 11

TLM Instalation Two types: Assembly supervision Full Assembly including labour and devices/tools Estimated time between 2 and 6 weeks. (depending on the site conditions) Page 12

TLM Comissioning Comissioning is transformer functional check and its system integration. It holds of: Functionals checking of auxiliary systems Tests and Electrical measurements Performed in accordance with customers/siemens rules/standards Estimated time of 3 days to 1 week depending on the specific conditions. Page 13

TLM Instalation - Facilities Page 14

TLM Agenda introduction Instalation and Comissioning Condition Assessment monitoring Repair and Retrofit Spare Parts - Solutions After Sales andtraining Page 15

TLM situations that every single customer is exposed to: Transformer life* decreases naturally with time as a consequence of natural ageing processes. operating temperatures (load, ambient) moisture content and increase (i.e. as a result of ageing) oxygen level and inrush (through conservator, ) mechanical & electrical stress (short circuit events, harmonics, system overvoltages, ) * The design life of a transformer is defined as the life of the cellulosic insulation according to L.Pettersson, 1990 Page 16

TLM - condition assessment diagnostics SITRAM DIAG SITRAM DIAG assessment-levels 1 2 3 High-Voltage tests on-site PD at applied voltage any HV according to IEC ANSI IEEE On-site tests & diagnostics recommended to be performed in regular intervals during outages, or if level 1 gives indication Non-electrical on-site assessments Complete oil analysis, DGA, furans, external visual inspection First level of classification and recommendations modular adjustable for all power transformers complete transformer populations Page 17

Condition Assessment Technical Report Level 1 The report consists in: Data bank structure Dissolved gas analysis (DGA) Insulating oil Physical and chemestry properties 2FAL Parameter Comissioning tests Maintenance and operational review Global Analysis Ranking of the equipments Overload impact in the life expectation Conclusions / Recommended actions Page 18

Analysis tools s Transformer Life Management Toolbox Artificial Neural Net and Fuzzy Interference 2 C H C H 2 2 2 4 2,0 T1 0,01 PD 0,1 0,1 T2 0,01 T1 0,2 1,0 4,0 CH 4 H D1 2,5 D1 D2 1,0 1,0 D2 0,6 CH H 4 2 C H C H 2 2 2 4 C 2 H 4 C2H6 0 3 1 0,2 T3 4 5 0,1 1,0 0/1 3/4 5 0,3 PD T1 2 0,1 T2 IEC 60599-3 Rogers Ratio Duval Triangle C H C H 2 4 2 6 CH C H 4 2 4 D1 D2 DT T3 1,0 3,0 C H 2 2 Human Expert normal high very high Gas Level NIF SIF FL T VFT NONE SOME IMP CRITICAL ANN Indication of Fault IEC normal high very high Gas Generation Rate Page 19

Condition Assessment Technical Report 100 90 80 70 60 50 40 30 20 10 0 TRT14 TRT12 TRT13 TRT11 TR0 T0 TR2 T1 T2 TRT23 TRT26 TRT24 TRT22 TR1 TRT25 TRT21 TR3 T3 TRT15 TRT16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Transformers Fuzzy classification, priority at the equipments that have simultaneous problems (gas, 2FAL, oil quality, etc). Page 20

TLM - condition assessment diagnostics SITRAM HVT SITRAM HVT High Voltage Testing Level 3 Diagnostics Routine tests acc to IEC IEEE standards Additional high voltage tests: - Applied voltage tests - Induced voltage tests - Partial Discharge measurement Helps arrive at critical decisions such as: keeping the unit in service carrying out a repair removing from service (scrap) Page 21

TLM Agenda Introduction Instalation and comissioning Condition Assessment Monitoring Repairs and Retrofit Spare Parts - Solutions After sales and Training Page 22

Monitoring Sensors Individual Transformers Multiple transformers TLMC Page 23

Main monitoring parameters bushings Oil level Top oil temp. Environment temp. OLTC lower oil temp. Load humidity Gas in oil Cooling control Page 24 Oil flux

Simotemp relay of thermal protection Page 25

TLM - online monitoring SITRAM GAS-Guard. SITRAM GAS-Guard The DGA laboratory at the transformer gas chromatography optimized for use in the field Diagnosis of individual gases (acc. to IEC/ IEEE) Indication of load-dependent gas development Page 26

Monitoring Sensors Individual Transformers Multiple Transformers TLMC Page 27

Smart Monitor Descentralized solution Page 28

Smart Monitor Monitor stand-alone, instaled and locally accessed. Every monitor is responsable for diagnostic of one transformer. It can accessed by Web interface and addicionaly local access. External status indication by LEDs in the panel. Page 29

Monitoring Sensors Individual Transformers Multiple Transformers TLMC Page 30

TMDS Centralized solution Page 31

Substation Arquitecture Local Central Panel Panel WebServer Local Panel Engineering Server LAN WAN Local Panel Anel Optic fiber Page 32

TMDS Multiple substations Arquitecture Substation 1 Substation 2. Substation n WAN Page 33 Control Center

Local Panel Page 34

Central Panel Page 35 Frontal view Back View

Monitoramento Sensors Individual Transformers Multiple Transformers TLMC Page 36

TLMC Transformer Life Management Central Monitoring Center Page 37

TLMC Data Transmission by mobile Data collect Firewall Engineering server Data collect GPRS MONITORING CENTER Data collect Page 38

TLMC Monitoring Center Customer Data Process and Analysis Data Bank Action Follow-up with Customer Page 39 TLMC Assets managing Diagnostics / Sample Service and field support Monitoring / on-line support Managing of transformers data / reactors

TLM Agenda Introduction Instalation and Comissioning Condition Assessment Monitoring Repairs and Retrofit Spare Parts - Solutions After Sales and Training Page 40

REPAIR OR BUY A NEW TRANSFORMER COMPARATIVE ADVANTAGE AND DISADVANTAGES TO REPAIR ADVANTAGE Maximum cost of 70% of new equipment. (Considering scrap and the work performed in workshop) Small installation costs DISADVANTAGES Unavailability of equipment during the repair period. Usually No load losses is little bit higher. Short delivery time Small assets Possibility to increase the capacity up to 30% (using a conventional raw materials). Same warranty period. Page 41

Repair in Workshop Reactor repair Opening 800 kv transformer tank Page 42

Repair in Workshop Main Brazilian Facilities Dedicated area to repair up to 150 MVA 230 kv (1300 m2), distributed in two areas Two cranes (80 ton and 50 ton) Segregated areas dirt and clean areas Place to parking tanks, conservators Hot oil spray devices Core table Page 43

REPAIR ON SITE OR ON WORKSHOP MR$ 2.200,00 2.000,00 1.800,00 1.600,00 1.400,00 1.200,00 1.000,00 800,00 600,00 400,00 200,00 - Structure costs x Transportation costs Sheltered place installation with lifting devices 250 KM 700 KM 1300 KM 2300 KM Structure 30 ton 50 ton 72 ton 112 ton 150 ton 262 ton Page 44

TLM - emergency support solutions on-site SITRAM REP SITRAM REP Repair On Site fast intervention solutions emergency support avoiding costly shipping to workshops Accurately adapted mobile workshop solutions shipped on site, providing optimum dry and clean working environment Well experienced and perfectly equipped supervising crews guaranteeing an efficient working process on-site Efficient project management along the whole repair process with direct access to TLM engineering and spare parts Page 45

Transformers Repairs and Retrofit Page 46

Repair on site Feasibility to repair in field: Large distances and long transportation period. Road in bad condition. High transportation cost. Large amount of transformers in same place, in order to dilute the costs of structure in field. Resulting: More competitive price Small repair period Possibility to follow all repair process by customer. Same warranty period of transformer repaired in workshop. Page 47

Repair on site Page 48

Necessary facilities to Repair on site Pressurized cabinet and retracted cabinet roof Page 49

Necessary facilities to Repair on site Core table assembling Page 50

Necessary facilities to Repair on site Tank and special devices to winding dispatch. Test winding device Page 51

Necessary facilities to Repair on site Mobile Transformers Test Unit Electrical resistance Voltage Ratio Insulating resi stance Angle displacement and phase sequence No load loss / excitation current Impedance and Load losse s Induced voltage of short period Induced voltge with partial discharge measurement Acce ssories Functional SFRA (special) Page 52

TLM Agenda Introduction Instalation and Comissioning Condition Assessment Monitoring Reparos e Retrofit Spare Parts - Solutions After Sales and Training Page 53

Spare Parts - Solutions Bushings On load tap changers (OLTC) Bombs, fans Protection relays (Buchholz relay) Indicators (temperature, oil, level, Oil flux) Gaskets Rubber bags Valves Dehydrant air Bushing Buchholz relays Page 54

Spare Parts Estimated life period Item Estimated life period Seriousness Probability (years) Solid porcelain bushing 20-30 High Low Condensive bushing 15-20 Very high Medium Off load Tap changer 25-30 Very high Medium Bucholz Relay 10-15 Medium Medium Pressure relief Valve 10-15 High Medium Winding/oil temperature indicator 10-15 Medium Medium Oil level indicator 5-15 Low Medium Oil/water flux indicator 5-10 Low Medium Fans 10-15 Medium Medium Bombs 10-15 High Medium Gaskets 5-10 Low High Rubber bag 10-15 Low Medium Valves 10-15 Low High Dehydrant air 5-10 Low Medium Page 55

TLM - thermal improvement SITRAM COOL (Transviso) SITRAM COOL (Transviso) A sophisticated cooling upgrade as retrofit self-learning and self-optimizing optimizing the thermal efficiency minimising noise & losses Higher airflow with lower power consumption Reduced noise levels, more efficient fans Adjusting the cooling according to power consumption, temperatures, limits on noise radiation, ) Smooth temperature profile avoiding peaks and downs Page 56

TLM - moisture reduction SITRAM DRY SITRAM DRY reliable and proven drying methods, specifically accustomed to the needs Page 57

TLM - oxygen reduction SITRAM SEAL Air Oil SITRAM SEAL Hermetic sealing retrofitting rubber bags in conservators to avoid unwanted intrusion from outside of: Air and oxygen Moisture Individual designs possible according to the transformer size and local conditions Page 58

TLM Agenda Introduction Instalation and Comissioning Condition Assessment Monitoring Repairs and Retrofit Spare Parts After Sales and training Page 59

After Sales and Training After Sales After sales of power and distribution transformers are including in TLM group in order to improve the sinergy. Training: - Transformers basic concepts - Assembling and inspection - Comissionig Tests - Preventive and corrective Maintenance - Operation - Oil sampling and results analisys Page 60

Thank you for your attention! Page 61 For internal use only / Copyright Siemens AG 2008. All rights reserved.

TLM - where to contact, how to get information www.siemens.com/energy/tlm TLM@siemens.com 7 segments - for customers 5 segments - for simplified reporting info material in PDF - for easy print Page 62 SITRAM DIAG SITRAM DRY SITRAM HVT SITRAM MONITORING MONITORING LEAFLET in preparation SITRAM COOL SITRAM SEAL SITRAM REPAIR

Page 63

Page 64

TLM - repair & refurbishment SITRAM REP SITRAM REP Repair In Workshop repair, refurbishment, reconstruction, modification, improvement - any brand A dedicated repair facility is being made available at the traditional Trafo Union workshop in Nürnberg. Centrally located in Europe, allowing cost effective access by rail and barge Modern and accurate design, materials and manufacturing standards is essential for quality and reliability in the industry. The integrative support and expertise from our global experts is made available to repair facilities throughout the world Page 65

Organisational changes 01.10.07 MCS reorganised to TLM P OI = 5,4 MIO Page 66 OI = 12 MIO

TLM SITRAM matching set of solutions Condition assessment SITRAM DIAG diagnostics in 3 levels SITRAM HVT high-voltage testing Condition monitoring SITRAM MONITORING on-line condition monitoring Temperature SITRAM COOL (Transviso) intelligent cooling system Moisture SITRAM DRYING on-line DRY; off-line LFH, HOS Oil quality SITRAM REG on-line oil-regeneration Oxygen inrush SITRAM SEAL ageing prevention air sealing Repair & refurbishment SITRAM REP repair on-site, or in workshops Page 67