CNG & Hydrogen Tank Safety, R&D, and Testing



Similar documents
International Forum on Pressure Vessels for Hydrogen and Natural Gas Vehicles

Fundamentals and practice of CNG safety -

THE INSTRUCTIONS PRESENTED HERE ARE ORIENTED TO USERS OF CNG CYLINDERS AS WELL AS TO TECHNICIANS IN CHARGE OF THEIR INSTALLATION

Hydrogen-Powered Vehicles: A Comparison of the European Legislation and the Draft UNECE Global Technical Regulation

CNG and Hydrogen Vehicle Fuel Tank Failure Incidents, Testing, and Preventive Measures

Alternative Fuels. Overview

mobile pipeline Bulk transportation and storage of energy gases

What Is a Typical CNG Vehicle?

A Feasibility Study. Steven C. Agee, Ph.D. Shouro Dasgupta, B.S.B. Alexis Caron, B.S.B.

70 Mpa Hydrogen Refuelling Stations

Daryl Patrishkoff, PMP Chief Executive Officer Center for Professional Studies

Safety issues of hydrogen in vehicles Frano Barbir Energy Partners 1501 Northpoint Pkwy, #102 West Palm Beach, FL 33407, U.S.A.

Pressure Vessels (Air Compressors) and LPG Tanks

Guidelines the DNV way

Northeast Gas Association (NGA) 2012 Sales and Marketing Conference. Mike Manning Director of Marketing and Business Development AVSG LP Boston, MA

Portable Pipelines for First Responders. Chris Christopoulos, Jr.

REAL AND IDEAL GAS THERMODYNAMIC ANALYSIS OF SINGLE RESERVOIR FILLING PROCESS OF NATURAL GAS VEHICLE CYLINDERS

CSA Group Safety Standards for Oil and Gas Pipeline Systems: A Life-Cycle Approach

Portable Pipelines for First Responders

Clean Abundant and Economical Natural Gas

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

List of Frequently Utilized Storage Tank Standards and Practices

Oil and Gas Pipeline Design, Maintenance and Repair

International Maritime Dangerous Goods (IMDG) Special Provision 961 and 962

What is CNG? CNG is compressed natural gas.

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Propane as the Alternate Fuel for Fleets

INSTALLATION AND START UP REPORT CERTIFYING THE CORRECT FUNCTIONALITY OF THE AD HOC REFUELLING STATION LIFE+ MHYBUS LIFE 07-ENV/IT/000434

Emergency Response Guide

Compressed Gas Cylinder Storage and Handling Guide

Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles

The Achilles Heel of Natural Gas Vehicles: The Symptoms, Diagnosis and Prevention of Oil Carryover

NASDAQ:BLDP TSX:BLD. Smarter Solutions for a Clean Energy Future

Advantages and Disadvantages of the Preferred Alternative Fuels

Hydrogen Powered Bus Fleets Hydrogen Supply & Fueling. National Fuel Cell Bus Workshop October 5, New Orleans, LA

IMW IMW Industries Ltd. CNG Primer. and Product Overview. CNG solutions for the real world

The Tesla Roadster battery pack is comprised of about 6800 of these cells, and the entire pack has a mass of about 450kg.

FIREFIGHTER NEAR MISS

Part 0 - Classification and Surveys Classification and Surveys I

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

UCLA - Compressed Gas Cylinder Storage and Handling

Diagram of components 2. Reducer..3

Integrated Custom Systems

Engineering & Testing Services. Hydraulic Fitting Design and Hydro-Mechanical Testing

RISK BASED INSPECTION (RBI)

ENVIRONMENTAL TESTING SERVICES. Product and component performance verification

Ron Eickelman President, Agility Fuel Systems

Copyright 1999 Inter-Industry Conference On Auto Collision Repair v.4.0

Ethanol Vehicle and Infrastructure Codes and Standards Citations

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

2012 Civic Natural Gas Retail & Fleet Markets. NGV Bridge Fleet Framework Summit March 26, 2013

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

TRANSPORT OF DANGEROUS GOODS

GAS QUALITY CHALLENGES TO SUPPORT DEVELOPING OF NATURAL GAS AS FUEL FOR VEHICLES IN INDONESIA

GTM PORTABLE GAS TRANSPORT. a breakthrough in high pressure gas transports, holding twice as much a comparable steel transports at 40% of the weight

Reference in RID/ADR (restructured) to published standards and standards in preparation at CEN TC 23/256/261/268/286/296

U.S. Department of Energy-Funded Performance Validation of Fuel Cell Material Handling Equipment

Backup Fuel Oil System Decommissioning & Restoration Plan

ANALYSIS OF FIRE HAZARD AND SAFETY REQUIREMENTS OF A SEA VESSEL ENGINE ROOMS

PERFORMANCE AT HAND. RED LINE Hand Portable Fire Extinguishers

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

(1) number 110. of a type (1) - Gas flow. adjuster (1) P.O. Box The Netherlands. Page 1 of 5

Vapor Corrosion Inhibitors (VCIs) for Storage Tanks Corrosion Controlled Cost Controlled

Natural Gas Information Contents

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Pressurized Hydrogen Storage - Jo Suzuki, Kunihiro Takahashi

Avoiding Burning Through: Control the Inside Surface Temperature, Not the Pressure

Compressed Gas Cylinders Safety Policy

A Guide to the European Standard for Safety Storage Cabinets (BS EN )

LOW PERMEATION FUEL TANKS

Leak detection of systems

Nylon 612: Viable Alternative Tubing Constructions in Fuel Systems

MOTOR FUEL DISPENSING SAFETY

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Emergency Response Guide

FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES

MaxCell Technical Manual Design Parameters

The Original and Patented Stackable Poly Tanks. When You Want to Beat the Drum!

OIL & MARINE PRODUCT RANGE. Dock & onshore Floating roof tank drain Mooring Rig supply

ASTM D 1599 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and Fittings

Summary of risks with conductive and nonconductive plastic pipes at retail petrol stations

OREGON FIRE CODE Interpretations and Technical Advisories

ASME B31.3 Process Piping. Scope of B31.3 Course

Hydrogen Sulfide in Petroleum. Mike Nicholson/Tim O BrienO Baker Petrolite Corporation

Giornata del Metano per i Trasporti. Applicazione per il Trasporto Pesante

HyApproval. Handbook for Approval of Hydrogen Refuelling Stations. Reinhold Wurster (LBST) on behalf of the HyApproval Consortium (

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

New Cable Tie Type Classifications

With Focus on Hydrogen and Fuel Cell Electric Vehicles

Rubber-to-Metal Bonding

SPECIALTY FIBER OPTIC CABLE. Downhole Sensing Subsea

Transcription:

> Powertech Labs Inc. CNG & Hydrogen Tank Safety, R&D, and Testing 012.10.2009 Presented by Joe Wong, P.Eng.

PRESENTATION OBJECTIVES Present experience from CNG in-service tank performance. The process of tank standards development. Discuss some of the current studies on Hydrogen tank development and safety. 1

POWERTECH Hydrogen & CNG Services Certification testing of individual high pressure components Design Verification, Performance, End-of-Life testing of complete fuel systems Design, construction, and operation of Hydrogen Fill Stations Safety Studies Standards Development 2

Compressed Natural Gas Vehicles 2,500,000 2,000,000 1,500,000 1,000,000 500,000 - Pakistan Argentina Brazil Iran India Italy China Colombia Bangladesh Thailand Ukraine USA Others 9 million vehicles worldwide 14,000 stations 3

Storage Tank Technologies 4 basic types of tank designs pressure vessels Type 1 all metal Type 2 metal liner with hoop wrapped composite Type 3 metal liner with fully wrapped composite Type 4 Plastic liner with fully wrapped composite 4

Tank Designs in CNG Service Primarily use steel tanks for CNG Glass fiber reinforced tank designs in CNG use since 1982 Carbon fiber reinforced tank designs in CNG use since 1992 Many tens of thousands carbon fiber tanks now in service (primarily transit bus use) Carbon fiber performance far superior to glass fibers Service pressures - 200 bar and 250 bar 5

Tank Designs in Hydrogen Service Primarily use composite tanks for hydrogen fuel cell vehicles 250 bar carbon fiber reinforced tank design in fuel cell bus demonstration in 1994. Storage pressures increased to 350 bar in 2000 Today, most auto OEMs have 700 bar tanks for on-board storage 500 km range with 5kg H2 1994 Ballard Fuel Cell Bus 6

Standards Development CNG & Hydrogen History In 1983 - requested by Gas Utility to investigate CNG cylinder safety Determined a lack of safety standards : ISO 11439 for CNG cylinders NGV2 for CNG containers CSA B51 for CNG cylinders 7 In 1994 - requested by Ballard to determine if safe to use CNG cylinders for hydrogen Determined a lack of any standards Powertech now: ISO 15869 for Hydrogen tanks HGV2 for Hydrogen tanks CSA B51 (first published hydrogen fuel tank standard in world) HGV3.1 for H 2 vehicle components ISO 17268 for H 2 fill connectors EIHP (European Integrated Hydrogen Program) HGV4.3 for Station Performance SAE J2578 SAE J2579 SAE J2601

Standards Development CNG Standards developed from in-service experience Vehicle service conditions End user requirements In-service failures / known failure mechanisms In-service abuse Collision Manufacturing problems Design problems 8

Vehicle Service Conditions Road conditions are very severe environments for pressure vessels Temperature extremes (-40ºF to +185 ºF in vehicles) Multiple fills (pressure changes) = fatigue cracking Exposure to road environments and cargo spillage Vibration Vehicle fires Collision Standards require tests or installation requirements for all these conditions 9

Consumer Desires for CNG or Hydrogen storage Same requirements as gasoline vehicles Sufficient range Same weight Same storage space in trunk Same level of safety Same cost Same fueling procedures 10

In-service Failures Powertech has been testing CNG storage systems since 1983 Powertech has maintained a cylinder failure database through world wide contacts Examined CNG cylinder field failure database to determine if trends evident Limited to incidents involving catastrophic rupture of cylinders, although major leaks attributed solely to the cylinder were included From 2000-2008, there were 26 CNG cylinder failures. Other multiple cylinder failures attributable to leakage failure mode : Type 1 steel pinhole leaks (<50) Type 4 plastic liner leak incidents (100 s) 11

12 In-Service CNG Tank Ruptures

FAILURE INCIDENTS REPORTED BY FAILURE CAUSE Data classified according to eight unique failure causes: Mechanical Damage External abrasion and/or impact Environmental Damage External environment assisted, typically SCC Overpressure Faulty fueling equipment or faulty CNG cylinder valves Vehicle fire Faulty PRDs or lack of PRDs; localized fires Plastic Liner Issues Man. defects incl. cracking at end boss/liner interface, flawed welds, liner seal failures Metal Liner Issues Man. defects incl. pinhole leaks, laminations, poor heat treat practice 13

No. of Failure Incidents FAILURE INCIDENTS REPORTED BY FAILURE CAUSE 18 16 16 14 12 12 10 8 8 6 5 6 4 3 3 2 1 0 Mechanical Damage Environmental Damage Overpressure Vehicle Fire Plastic Liner Issues Metal Liner Man. Issues User Error Unknown Cause Failure Cause 14

No. of Failure Incidents FAILURE INCIDENTS REPORTED BY CYLINDER TYPE Type 1 steel cylinders involved in nearly 50% of failure incidents 30 25 24 20 15 10 11 12 5 4 2 1 0 Type I Type II Steel/Glass Type II Alum/Glass Type III Alum/Glass Type III Alum Carbon Type IV Cylinder Type 15

No. of Failure Incidents FAILURE INCIDENTS REPORTED BY VEHICLE TYPE Aftermarket vehicles represent just over 50% of failure incidents Data is related as most aftermarket conversions employ low cost/readily available Type 1 cylinders Many of the installations less likely to follow sound engineering practice (regarding use of standards, materials/workmanship quality, installation codes, maintenance/inspection procedures) 35 32 30 25 20 15 15 10 7 5 16 0 OEM Vehicle After Market Vehicle OEM Bus Vehicle Type

In-service Damage Experience Tank dragged on road under vehicle after support strap broke. CNG vehicle crash no tank rupture Galvanic corrosion 17 Stress corrosion cracking due to acid attack on fibers

Type 4 Composite Tank Collision Damage Tanks mounted on CNG bus roof. The bus impacted a low overhead, collapsing the roof. Tank still exceeded minimum burst pressure. Tanks mounted on CNG bus roof. The bus impacted a low overhead, collapsing the roof. Tank punctured, released gas but did not rupture. 18

Standard Tests for Design Qualification Performance tests were designed and validated including: Ambient Cycling Test Environmental Test Extreme Temperature Pressure Test Hydrostatic Burst Test Composite Flaw Test Drop Test Accelerated Stress Rupture Test Permeation Test Natural Gas or Hydrogen Cycling Test Bonfire test Gunfire Penetration Test 19

Tank Testing - Hydraulic Pressure Environmental and chemical effects Flaw/Damage Tolerance Burst Test Powertech Cylinder Test Facilities Burst test up to 2,800 bar Hydraulic pressure cycling up to 1,500 bar Drop Test 20

21 Development of 700 bar Tanks

Destructive Safety Testing Facilities Bonfire Testing Bonfire without PRD Penetration (Gunfire) Testing Flammable Gas Ignition High Pressure Gas Release Crush Testing (Static and Dynamic) Laminate Damage Tolerance Vehicle Fire Vehicle Crash 22

23 CNG and Hydrogen Cylinder Gunfire Penetration Tests

24 Vehicle Fire Tests - CNG & Hydrogen Tanks

25 Dynamic Crush Test Overview Valve end impact @ 35 MPa hydrogen

26 Dynamic Crush Test Detail Valve end impact @ 35 MPa hydrogen

Filling Conditions with Hydrogen How to ensure a full fill? Heating of H2 during filling 700 bar @15C and 875 bar @ 85C Communication between vehicle & dispenser? Flow control? Pre-cooling of gas? 27 Figure from :Schneider, J., Gambone, L., McDougall, M., et al., 70 MPa Hydrogen Storage Fueling Testing, Proceedings of the Zero Regio Workshop, World Hydrogen Technologies Conference 2007, November 4-7, 2007, Montecatini, Italy.

Multi-Client 70 MPa Hydrogen Fast Fill Study Outputs of the study: Minimum fueling time at each ambient condition to safely fill all fuel systems Pre-cooling levels for each ambient condition Energy required for pre-cooling Temperature gradients throughout the fuel system Durability of fuel system under extreme fueling conditions Performance data of station components (flow meter, flow controller, nozzles, hoses, compressors, etc.) Consortium members: Air Liquide, BP, Nippon Oil, Sandia (US DOE), Shell, Iwatani, Chrysler, Ford, GM, Nissan, Honda, Toyota. 28

70 MPa Hydrogen Fast Fill Test Facility Fueling Station Simulator Fuel System Chamber -40C to +50C Ground Storage Chamber 875 bar -40C to +50C 29

30 70 MPa Fast Fill 3 Minutes Ambient Temp -40C

OEM 2 +50C, -30C PC, 3 Minute CPRR 31 *Powertech Fuel System of same size and type as Nissan Fuel System

32 Multi-Client 70 MPa Fast Fill Study OEM-1 Fuel System

SUMMARY In-service experience with CNG tanks have provided input into the development of CNG & Hydrogen tank standards Higher pressures are required for hydrogen storage in order to achieve the range targets for vehicles. Studies are underway to provide data to standards being developed by organizations such as SAE, ISO, and CSA. Areas of study include: Fire safety Fueling protocol Impact resistance 33