CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping



Similar documents
CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

CyFlow Space Your flexible flow cytometer

Partec PAS. Your Flow Cytometer.

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Boundary-breaking acoustic focusing cytometry

CyAn : 11 Parameter Desktop Flow Cytometer

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Cell Cycle Tutorial. Contents

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

FlowSight. Flow cytometry with vision

BD FACSComp Software Tutorial

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

COMPENSATION MIT Flow Cytometry Core Facility

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Introduction to flow cytometry

Standardization, Calibration and Quality Control

These particles have something in common

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

Cytell Cell Imaging System

Easy to use. Compact. Flexible. Sorting Chip

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

Introduction to Flow Cytometry

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

APPLICATION INFORMATION

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE

INSIDE THE BLACK BOX

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8

AxioCam MR The All-round Camera for Biology, Medicine and Materials Analysis Digital Documentation in Microscopy

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Fluorescent Array Imaging Reader

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

How to operate the BD FACSCanto flow cytometer

Introduction to Flow Cytometry

Immunophenotyping peripheral blood cells

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

FloMax Software for Cytometry. Operating Manual - Data Analysis. Version 2.3, FloMax Operating Manual Data Analysis 1

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Imaging and Bioinformatics Software

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

Single Mode Fiber Lasers

UCHC Guide to FACS DiVa. LSR II instruments

Introduction to Flow Cytometry:

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Setting up and calibration of a flow cytometer for multicolor immunophenotyping

Flow Cytometry A Basic Overview

MH - Gesellschaft für Hardware/Software mbh

Flow cytometry basics fluidics, optics, electronics...

DELPHI 27 V 2016 CYTOMETRY STRATEGIES IN THE DIAGNOSIS OF HEMATOLOGICAL DISEASES

Zecotek S Light Projection Network Marketing

Description: Multiparameter System (4 or 8 channels)

The best lab standard. 1,4 Megapixels 2/3 inch sensor Giant pixel size 6 times optical zoom Massive 16-bit imaging for enhanced dynamic

BD FACSCanto Flow Cytometer. Efficient Easy Powerful

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Becton-Dickinson FACSCalibur Flow Cytometer Instructions

FACS Laboratory. BD LSRs Operator Training. Training Guide.

PRODUCT INFORMATION. Insight+ Uses and Features

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

BD FC Beads 8-Color Kit for BD OneFlow Assays

Three Rules for Compensation Controls

Principles of Flowcytometry

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

Compensation: An Instrumental Perspective

Voltech DC1000. Precision DC Bias Current Source

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

BD FACSVerse. Simply brilliant

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

DIODE PUMPED CRYSTALASER

Compensation in Flow Cytometry

Leica TCS SP5 Confocal Laser Scanning Microscope User Guide 1. BASIC IMAGE ACQUISITION

UCHC Guide to CellQuest Pro. FACS Calibur instruments

Uses of Flow Cytometry

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

DIGITAL DISPLACEMENT RISING STEP LOAD LRA/RSL TEST EQUIPMENT

BD CellQuest Pro Software Analysis Tutorial

Experiment 5. Lasers and laser mode structure

NEW. EVEN MORE data acquisition and test stand automation

FACSCanto RUO Special Order QUICK REFERENCE GUIDE

Compensation Basics - Bagwell. Compensation Basics. C. Bruce Bagwell MD, Ph.D. Verity Software House, Inc.

pb tec solutions GmbH, Max-Planck-Str. 11, Alzenau (Germany) Tel.: Fax:

Zeiss 780 Training Notes

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

LSR II Users Guide Stanford Shared FACS Facility 06/10/13

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

AxioCam HR The Camera that Challenges your Microscope

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Transcription:

CyFlow SL Healthcare Immunology Portable FCM System for 3-colour Immunophenotyping

01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results in research and clinical routine within the shortest possible time - The challenge for flow cytometry instrumentation, automation and software. A well-established network of subsidiaries and distributors in more than 60 countries worldwide characterizes Partec s commitment to the increasing focus and need for global access to Flow Cytometry instrumentation and application support: www.partec.com/partec/distributors.html More than 35 Years of Experience and Professional Expertise Partec pioneer in Flow Cytometry since 1968 responds to these requirements with the new generation of Windows XP based CyFlow and PAS FCM systems featuring innovative computer controlled flow systems, modular optical systems with advanced PMTs for all optical channels, most modern computer and digital electronic technologies including fast and precise 16 bit ADC converters and realtime data acquisition and display.

02 HIGHLIGHTS CyFlow SL 3-Colour FCM System _ ultracompact and fully equipped mobile/portable instrument _ dimensions [cm]: L 43 x H 16 x D 37 _ highest stability/robustness and highest precision _ 5 optical parameters: FSC, SSC, FL-1, FL-2, FL-3 _ 20mW@488nm blue solid state laser (50mW@488nm optional) _ other laser light sources optional (UV, violet, green, yellow, red) _ Windows XP FloMax software for realtime data acquisition, data display, and data evaluation _ parallel 16 bit digital pulse processing _ single platform True Volumetric Absolute Counting (TVAC) _ submicron particle detection (<0.2µm) for scatter _ high fluorescence sensitivity < 100 MESF (FITC) < 50 MESF (PE) _ power connection: regular 100/240 V AC or car battery (12 V DC) _ new level of price / performance ratio

03 TECHNOLOGY CyFlow SL 3-Colour FCM System The ultracompact and portable CyFlow SL provides most accurate and uniquely affordable 3-colour analysis for use in research and routine applications. Compact The CyFlow SL is a fully equipped 5 parameter (FSC, SSC + 3 colour fluorescence) portable / desktop flow cytometer. It contains a solid state/diode laser for UV/violet, blue, green, or red excitation. In the blue laser version it is fully compatible with standard flow cytometers used in clinical and research immunology. Its small size and robustness make the CyFlow SL easy to place even in laboratories with limited space. It is the perfect device to take over the routine immunology from more expensive and service demanding large flow cytometers; dramatical cut down of running costs is achieved. High Stability The complete optical system of the CyFlow SL is designed as one solid metal block. Time consuming installation and optical checks, realignments of lasers and readjustments are no longer required. High Precision The solid state lasers of CyFlow SL show a unique short and long term stability superior over water and air cooled gas lasers. High precision analysis, as required in various fields of cell biology, pathology and immunology is maintained by the extraordinary long life time of solid state lasers. Power Connection The CyFlow SL does not need particular power line connections, it runs on regular 100/240 V AC as well as 12 V DC. For field studies, in remote areas, and places with unstable power lines, the CyFlow SL can easily be connected to a car or boat battery. It is perfectly prepared for scientific expeditions, field studies, and as mobile flow cytometer for decentralized use close to patients in hospitals and small medical service stations. Price/Performance Ratio The CyFlow SL opens a new era of flow cytometry, it supports all applications as known from traditional large flow cytometers at equipment costs roughly half the price of them. In addition, service and running costs as well as maintenance are reduced to a neglectible minimum near zero. Selection of Fluorochromes for the CyFlow SL Light Source System 20 mw or 50 mw GREEN FITC GFP Alexa Fluor 488 SYTO 9 FDA ORANGE PE eyfp Pi PE-Texas Red RED PE-Cy5 PE-Cy5.5 PerCP PerCP-Cy5.5 EB Nilred PE-Cy7

FLUORESCENCE AND SIDE SCATTER The unique Partec quartz flow cuvette is the heart of the CyFlow SL, ensuring that particles and cells cross the excitation light with the best possible precision. The design of the flow cuvette incorporates more than 35 years of experience in handling fluids with sub-micrometer and nanoliter precision. Thanks to the optical and mechanical precision of the flow cuvette, superior results are guaranteed for all parameters, e.g. coefficients of variation (CVs) of about 2 % on all fluorescence channels. The sample is transported with the help of a computer controlled digital syringe pump, part of a virtually cross-contamination-free fluid system. The True Volumetric Absolute Counting (TVAC) is a unique feature of all Partec Flow Cytometers, offering highest absolute counting precision and accuracy. The CyFlow SL analyses concentrations of any particle or cell subpopulation of interest using True Volumetric Absolute Counting. This unique method is solely based on the fundamental definition of absolute counting respectively the particle concentration (c) which is equal to the counted number (N) of particles (e.g. cells) in a given volume (V), c = N / V. In the CyFlow SL, the volume is measured directly by mechanical means, rather than by calibration with expensive beads with a sometimes doubtful given nominal concentration. Thus, the precision of volume measurement is defined by a fixed mechanical design, eliminating any errors related to varying bead concentrations or bead aggregation. The CyFlow SL allows the analysis of a fixed volume as defined by the distance between two platinum electrodes reaching into the sample tube with a given diameter. Alternatively, a well defined volume of free choice involving the digital sample speed control can be used. Benefits of True Volumetric Absolute Counting: _ digital volumetric precision by mechanical design: CV< 2 % _ no errors related to calibration _ no additional time and preparation steps for reference beads or haematology reference count _ no expenses for calibration beads _ no separate haematology counter required

Principle of Partec True Volumetric Absolute Counting The Partec CyFlow SL is your complete solution for routine immunophenotyping. 3-color analysis of CD3/CD8/CD45 with CyFlow SL. CyLyse lyse / no-wash scatterplot showing the good scatter resolution. Rapid and reliable automated clinical result reporting The included Partec FloMax Report software generates automated clinical result reports in Microsoft Word format according to laboratorydefined and flexibly adaptable report forms, consisting of the hospital/ laboratory logo(s), freely positionable and sizeable histogram figures, tables for the analysis results, calculation formulas and free text, e.g. the diagnosis comments. All editing and annotation features of Word can be used before printing the completed report and saving it as a Word document. An example report for a 3-colour immunophenotyping analysis is being reproduced in the figure on the left side, directly displaying all clinical relevant histograms and results.

04 ANALYZE CyFlow SL 3-Colour FCM System The Windows XP FloMax software integrates instrument control including acquisition, on- and offline data analysis, onand offline compensation into a complete software package. Predefined and freely adaptable instrument settings and panels facilitate switching between different applications. FloMax is optimized for immunophenotyping, microbiology analysis, cell cycle, DNA ploidy, and other scientific flow cytometric analysis. Data is stored in FCS flow cytometry standard file format for easy exchange with other analysis software. One of the unique features is the digital on- and offline colour crosstalk compensation of the spectral overlap of fluorescence from simultaneously analysed dyes. The N-colour compensation algorithm allows a correction of the crosstalk between any parameters without the need to rerun a sample. FloMax optimally supports the True Volumetric Absolute Counting feature of the CyFlow space, displaying particle concentrations for any subsets of cells, even if defined by a gate at a later time after the acquisition. Full flexibility and automation by the multi-tube FloMax panel system and the FloMax Report system within the FloMax software package. The flexible FloMax panel system allows automated analysis of repeating sample series employing different dyes or instrument settings. The FloMax Report system generates easy-to-adapt automated single or multi-tube panel results. Reports can be automatically exported to Microsoft Word or Excel.

05 SPECIFICATIONS CyFlow SL 3-Colour FCM System www.cyclos-design.de GENERAL The CyFlow SL is a fully-equipped portable/ desktop flow cytometer. It analyses up to five optical parameters (FSC and SSC and 3 fluorescences) plus time parameter. It performs both fluorescence analysis and absolute cell counting without the need for reference beads. LIGHT SOURCES The instrument is equipped with a solid state laser featuring blue excitation at 488 nm (UV, violet, green, yellow or red lasers optionally available). OPTICS Modular optical system with 1 to 5 optical parameters. Each parameter is equipped with a photomultiplier tube (PMT) and integrated electronic preamplifier. Color CCD camera for video flow monitoring. FLOW SYSTEM Synthetic quartz flow cuvette (channel dimensions: 200 µm x 350 µm) for laminar sample flow. True Volumetric Absolute Counting based on precise counting and fluid volume measurement. Computer controlled precision syringe pump for contamination-free sample transport and volumetric absolute counting, pump speed continuously adjustable up to 1200 µl/min, sheath fluid pressure continuously adjustable from 0-500 mbar. Fluid level indicators for full waste and low sheath fluid. ELECTRONICS _ parallel signal processing for each of the optical channels with selectable linear, 3- or 4-decade logarithmic scale _ pulse height, area and width analysis for doublet discrimination _ 16 bit analog-to-digital converters, trigger on any parameter or parameter combinations COMPUTER Processor Pentium 3.2 GHz, 512 MB RAM Harddisk 160 GB 15 TFT (17, 19 optionally available) Floppy disk drive 1.44 MB and DVD/CD-RW combo drive Monitor, keyboard and mouse Microsoft Windows TM, Office Notebook optional SOFTWARE Partec FloMax software based on the Windows TM operating system for multi-parametric data acquisition, display, data analysis, and instrument control. Simultaneous representation in single parameter histograms or correlated dual parameter plots during data acquisition. True Volumetric Absolute Counting with determination of cell concentration, concentration of subpopulations for each region or gate, reselection of subpopulations for absolute counting. Realtime acquisition, multi-parameter N-color compensation, multi-parameter gating, multi-color gating. Real time software gating: 32 regions can be combined to 32 gates in free logical combinations. Individual instrument setups and acquisition displays can be saved in setup files. Multi-tube analysis can be predefined in panels. Automated panel acquisition. Report module: automated multi-tube report generation as MS Word or MS Excel document. FCS flow cytometry file standard. Network connection to laboratory information systems (LIS), PCs, and Apple Macintosh. POWER REQUIREMENTS 240 V AC, 60 VA, 50/60 Hz or 12 Volts DC/5A Weight: 17 kg For in vitro diagnostic use. Partec GmbH Otto-Hahn-Straße 32 48161 Münster Germany Fon +49 2534 8008-0 Fax +49 2534 8008-90 Mail: info@partec.com Web: www.partec.com 04.06