Replacing an AC Power Cord in a Power Shelf



Similar documents
Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

Front Panel Board Cable Replacement Instructions

Accessing the printer system board

Replacing the Gateway M320 Keyboard

GSM-EXT Cable Assembly Installation Guide

Processor Cage Fans, Front and Rear Replacement Instructions

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

UPGRADING AND SERVICING GUIDE

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

HP SATA/SAS hard drive and Solid State Drive installation

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Removing memory and option cards

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Figure 1-A This end of the cable is the side that will be plugged into the power adapter and DVR Card.

Small form factor bay converter and hard drive installation

Replacing the Gateway M675 Keyboard

Installation. Basic Rack Power Distribution Unit for Blade Servers

HP R12000 and R18000 DirectFlow UPS User Guide

apple Service Source Power Mac G4 Cube Updated June 2, Apple Computer, Inc. All rights reserved.

5800 Temperature Sensor Cable Assembly

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

Upgrading and Servicing Guide

LT Charging Cart for Laptops

4RU High Density Shelf Installation Instructions

HP UPS R1500 Generation 3

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

The Different Types of AC Power Connectors in North America

How To Set Up An Inverter

IMPORTANT SAFETY RULES TO FOLLOW

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

BRACKET LOCKING SCREW

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

Refer installation of power supplies to qualified service personnel.

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

Ceiling Fan Installation Instructions

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

RS Monitor Backlight Replacement

The Different Types of AC Power Connectors in North America

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

DE1600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Memory Modules User Guide

Anthro Tablet Charging Cabinets

HP 22-in-1 Media Card Reader

Model Number Electrical Compatibility Module Connector Type. M LL-S22 60 cell PV module MC-4 Type 2 Locking

HP 2400/2500 Ultra Light Docking Station User Guide

Operating Instructions

HP ProDisplay P19A LED Backlit Monitor. User Guide

Memory Installation Guide

How to Set Up Your NSM4000 Appliance

Compaq Presario Desktop Products. Upgrading and Servicing Guide

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Wireless Router Setup Manual

About the HotWire Slot Standalone Shelf

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

Electrical Wiring Methods, Components and Equipment for General Use. Approved for Public Release; Further Dissemination Unlimited

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Rack installation instructions

Serial ATA to Serial ATA

Rackable Systems S3012 3U STORAGE SERVER FIELD SERVICE MANUAL. Revision 1.0. S3012-Service-Manual-1.0 Oct. 10, 2004 Page 1 of 15

EPSON Stylus. Start Here

How SafePlug Smart Receptacles Can Save Money in Commercial Buildings

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

Fan, Cypress / GreenField Installation Instructions (sku )

DC400 Dispensing Cutoff System

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

INSTALLATION & SERVICE MANUAL. Display Panel

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

(Always POWER DOWN printer and UNPLUG before doing any repair work)

MAINTENANCE & TROUBLESHOOTING

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Power Supply Guide Version 1.0 for D-Show

ALTEC LANSING ONE YEAR LIMITED WARRANTY (TWO-YEAR LIMITED WARRANTY IN THE EUROPEAN UNION AND ASIA)

Introducing Your Cisco IP Phone

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Installation Instructions For Slider Casement Air Conditioners

Installing your upgrade processor

EasyNote TJ Series. Disassembly Manual

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

2013 VTech Printed in China US

How To Use An Nc Express5800 Card (Nec) With A Remote Management Card (Ec) On A Pc Or Mac Computer (Nemca) With An Ipa/Sda/Sdu) On An Ipad Or

Installing Your 960 or 980 Server into a Rackmount Cabinet

Installation Instructions

Internal Modem Installation with Windows 95

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Doorbell Intercom Security System

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Tablet Management Rack 16

42U/45U 28" Wide Rack Installation & Service Guide

56K PCI DATA/FAX Modem. User Manual

Inspiron 13. Service Manual Series. Computer Model: Inspiron Regulatory Model: P57G Regulatory Type: P57G001

Transcription:

Replacing an AC Power Cord in a Power Shelf No system shutdown is required to replace one AC power cord in a power shelf. All components in the enclosure continue to receive power from the other power cord. No tools are needed for this procedure. Unpack and inspect the replacement power cord. If the power cord is damaged, you need to order another one before continuing with this procedure. Note: Before you remove a power cord, make sure the PIB-to-PIB crossover cable is securely connected to both PIBs. This cable is necessary for power to be routed from a single power supply to both sides of the enclosure. See Power Shelf Bulkhead and Service Side of Power Shelf. To remove a power cord: 1 Review the Notes page before beginning the replacement procedure. 2 Unplug the power cord from the AC outlet. Note: In North America, the default AC power cords now have a twist-lock plug on the end that connects to the AC receptacle. 3 Lift up the locking bar on the power cord retainer. See Connecting and Disconnecting a Power Cord in a Power Shelf. 4 Remove the power cord connector from the retainer in the power shelf. You are now ready to install the replacement AC power cord. To install a power cord: 1 Orient the plug with the single contact on top, and insert the plug in the retainer. See Connecting and Disconnecting a Power Cord in a Power Shelf and AC Power Cord Installed in a Power Shelf. Fully seat the plug on the power supply connector prongs. You might need to move the plug from left to right and up and down to fully seat it. Note: If the plug does not easily fit on the power supply connector, unseat the power supply, install the plug in the retainer, and then reseat the power supply.

2 Swing the locking bar down until it engages one of the slots on the plug housing and snaps into place. Do not force the locking bar. If the locking bar does not engage easily, the plug might not be seated correctly, or you might have the wrong cable. Warning: The underside of the locking bar is sharp. Placing your fingers under the locking bar can result in injury. Failure to fully seat the plug into the retainer can result in cord damage from the locking bar. 3 Plug the other end of the power cord into the dedicated AC outlet. 4 If the circuit breaker was turned off to do this procedure, turn on the circuit breaker. 5 Verify that the power LED on the associated power supply is lit. This completes the power cord replacement procedure.

Figure: Power Shelf Bulkhead Ensure the PIB-to-PIB crossover cable connectors and the DC power cable connectors are fully seated. Partial view: the AC power cords and power interface board (PIB) covers are not shown.

Figure: Service Side of Power Shelf

Notes for Replacing an AC Power Cord in a Power Shelf The AC receptacles into which the server is connected must be accessible to the operator. Alternatively, the branch circuit breaker supplying power to each receptacle must be accessible to the operator and plainly marked so as to indicate that the circuit breaker is for this receptacle. Some AC power cords contain faulty connectors that when touched, vibrated, or flexed can cause intermittent power or the loss of a processor to occur. If the power cord molding is elliptical rather than square, or if the power cord part number is TPN 064583, you must replace the power cord offline with power cord TPN 421575. For more information, refer to FCO36048. The end of the AC power cord is caged in a holder that holds it in place for mating to the power supply. If the wrong AC power cord is installed, the power supply might push it back out of place without making a connection.

Figure: Connecting and Disconnecting an AC Power Cord in a Power Shelf This Figure illustrates how to open and close a power cord retainer on the back of the power shelf.

Figure: AC Power Cord Connector Installed in a Power Shelf