Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T



Similar documents
BD Trucount Tubes IVD

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Absolute counting using flow cytometry. Bright Count Microspheres

Minimal residual disease detection in Acute Myeloid Leukaemia on a Becton Dickinson flow cytometer

Immunophenotyping peripheral blood cells

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

APPLICATION INFORMATION

WHOLE BLOOD LYSING SOLUTION FOR FLOW CYTOMETRIC APPLICATIONS

Standardization, Calibration and Quality Control

Analyzing Samples for CD34 Enumeration Using the BD Stem Cell Enumeration Kit

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

COMPENSATION MIT Flow Cytometry Core Facility

Laboratory Procedure Manual

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Standard Operating Procedure

BD FACSComp Software Tutorial

Introduction to Flow Cytometry

ArC Amine Reactive Compensation Bead Kit

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

Boundary-breaking acoustic focusing cytometry

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Setting up and calibration of a flow cytometer for multicolor immunophenotyping

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

CyAn : 11 Parameter Desktop Flow Cytometer

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

EdU Flow Cytometry Kit. User Manual

LIVE/DEAD Fixable Dead Cell Stain Kits

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

Three Rules for Compensation Controls

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

These particles have something in common

Notes on titering antibodies

RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)

Deep profiling of multitube flow cytometry data Supplemental information

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

Introduction to flow cytometry

Fluorescence Compensation. Jennifer Wilshire, PhD

Compensation Controls Data Visualization Panel Development Gating Quantum Dots

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

Bacterial Detection and Live/Dead Discrimination by Flow Cytometry

Introduction to Flow Cytometry

Islet Viability Assessment by Single Cell Flow Cytometry

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

Cell Cycle Phase Determination Kit

Enumeration of CD34-positive hematopoietic progenitor cells by flow cytometry: comparison of a volumetric assay and the ISHAGE gating strategy

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry

Cell Cycle Tutorial. Contents

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Chapter 6. Antigen-Antibody Properties 10/3/2012. Antigen-Antibody Interactions: Principles and Applications. Precipitin reactions

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Introduction to Flow Cytometry:

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Canine creatine kinase MB isoenzyme (CK-MB)ELISA Kit

INSIDE THE BLACK BOX

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

Science is hard. Flow cytometry should be easy.

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

BD FC Beads 8-Color Kit for BD OneFlow Assays

Annexin V-EGFP Apoptosis Detection Kit

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Below is a list of things you should be aware of before you schedule your sort.

Annexin V-FITC Apoptosis Detection Kit

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

The success of bone marrow or peripheral blood stem

BD CellQuest Pro Software Analysis Tutorial

Uses of Flow Cytometry

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

Principles of Flowcytometry

Annexin V-FITC Apoptosis Detection Kit

Compensation in Flow Cytometry

Immunoglobulin E (IgE) concentrations in Human. Immunoglobulin E (IgE) Human ELISA Kit

PRODUCT INFORMATION SHEET Monoclonal antibodies detecting human antigens

BD FACSVerse. Simply brilliant

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

HIGH PERFORMANCE FLOW CYTOMETER FOR EVERYONE

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

Human Free Testosterone(F-TESTO) ELISA Kit

Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

MANUAL WBC LAB OBJECTIVE

Cancer Antigen CA125 Human ELISA Kit

Transcription:

Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom Cat. Reference: STP-25T Reagent provided:: 25 Stepcount tubes for 25 test INTENDED USE. Immunostep Stepcount tubes are designed for determining absolute counts of cells in peripheral blood, bone marrow, leukapheresis and culture medium samples using flow cytometry. Stepcount tubes are a single-platform system for absolute counts, which can be used in combination with monoclonal antibodies (MoAb) conjugated with different fluorochromes, which make possible to identify cell subpopulations for which the absolute count is intended. SUMARY Stepcount Procedure described in this data sheet is used for immunophenotyping techniques, and is based on known number lyophilized spheres that emit fluorescence at the wavelengths used in convencional flow cytometry. PRINCIPLES OF THE PROCEDURE The microspheres contained in the tubes are lyophilized and will be dissolved when the sample is added. As the number of particles is know we can establish a relationship with any other population identified by the antibodies that we have incorporated. Absolute counting of cells or cell subsets has a number of significant clinical applications as monitoring the disease status of HIV-infected patients, enumerating residual white blood cells in leukoreduced blood products, and assessing immunodeficiency in a variety of situations. The single-platform method (flow cytometry alone) has emerged as the method of choice for absolute cell enumeration. This technology counts only the cells of interest in a precisely determined blood volume. Exact cell identification is accomplished by a logical electronic gating algorithm capable of identifying lineage-specific immunofluorescent markers. Exclusion of unwanted cells is automatic. This extensive and detailed unit presents protocols for both volumetric and flow-rate determination of residual white blood cells and of leukocyte subsets. Keywords: absolute count; volumetric counting; flow rate cytometry; counting microsphere standards; single-platform absolute count; dual-platform absolute count; logical gate; lineage-specific markers; immunophenotyping; absolute residual WBC REAGENT Each box contain: 25 Stepcount tubes for 25 test. Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Number of microspheres per tube: This value is found on the Stepcount tubes label and is different for each batch. Particles mean diameter: 3.6 μm with a standard deviation of 0.25 μm Excitable at wavelengths from 365 to 650 nm Precautions For use on Research only Storage between 2º C and 8º C Protect from direct light Keep well closed Use with a lyse/no-wash procedure. No transfer the contents of the tube to another tube. The sample must have protein content similar to whole blood to obtain correct values. Protocol 1. For each patient sample, label a STEPCOUNT Tube with the reagent and sample identification number. Temper the sample and the tubes 2. Spin tubes in microfuge (short-spin) to ensure that spheres are at the bottom. 3. Pipette of the appropriate reagent just above the stainless steel retainer. Do not touch the pellet.

4. Pipette 50 μl of well-mixed, anticoagulated whole blood onto the side of the tube just above the white pellet. NOTE: Avoid smearing blood down the side of the tube. If whole blood remains on the side of the tube, it will not be stained with the reagent. Accuracy is critical. Use the reverse pipetting technique to pipette sample onto the side of the tube just above the retainer. Mix the sample until complete dissolution of the pellet. 5. Cap the tube and vortex gently to mix. Incubate for 15 minutes in the dark at room temperature (20 to 25 C). 6. Add 450 μl red blood cell (RBC) lysis buffer (strongly recommended ammonium chloride) to the tube. must be fully contained in this gate for a correct count. 2. Obtain the number of events in the absolute count bead region from an ungated FL1 vs FL2 dot plot. 7. Cap the tube and vortex gently to mix. Incubate for 15 minutes in the dark at room temperature. The sample is now ready to be analyzed on the flow cytometer. NOTE: Vortex the samples thoroughly (at low speed) to resuspend beads and reduce cell aggregation before running them on the flow cytometer. 3. Select the desired population and anoted the number of events. Adquisition and analysis. Before acquiring samples, verify the cytometer is correctly aligned and standardized for light scatter (FSC and SSC parameters must be set on linear amplification) and fluorescence intensity (FL1, FL2, FL3 FL4 parameters must be set on logarithmic amplification) and colour compensation has been set following the instructions of the cytometer manufacturer. Before acquiring samples, set the Threshold or Discriminator in parameter FSC to minimize debris and ensure population of interest are included. Gently mix the samples manually immediately prior to running on the flow cytometer to ensure thorough resuspension of cells and microspheres. Acquire and store all events possible. It is recommended to acquire at a low or medium speed to avoid cell aggregates. If you cannot acquire the total sample, acquire no more than 4 minutes without a stir sample. Example of CD3/CD8/CD45/CD4: 1. Gate the lymphocyte population from an FL3 vs SSC dot plot and adquire an adequate number of events. The population of Beads 4. The absolute number of the cell population of interest is determinated by dividing the number of cells of interest acquired by the number of beads acquired (FL1/FL2), and multiplying this result by the microsphere concentration (microsphere concentration is indicated in the label on the tube). Storage Store in the dark, at 2-8 C. Do not use after expiration date stamped on vial. If unexpected staining is observed which cannot be explained by variations in laboratory procedures and a problem with the product is suspected, contact our Technical Services tech@immunostep.com DO NOT FREEZE. Protect the fluorescent conjugates from the light.

Performance characteristics For all tests performed in the technical specifications has been used following combination of antibodies: CD3 FITC/ CD8 PE/ CD45 PerCP/ CD4 APC and CD45 FITC/CD34 PE. Cells were analyzed on a FACSCalibur (Becton Dickinson, San Jose, CA) flow cytometer, using Cell Quest acquisition software. Accuracy: We compared the results for the same sample, using the double platform and Stepcount. The samples are from healthy individuals with no apparent hematologic diseases. For this study, 64 samples were tested. Data were analyzed to determinate the different between Doble Plaform and Stepcount. The results appear in the Figure 1 and 2 COEFFICIENT (R 2 ) SLOPE Y- INTERCEPT 95% LOWER 95% UPPER CD3+ 0.978 1.03 23.606-32.820 80.032 CD3+/CD4+ 0.975 1.11-2.10-28.429 24.113 Cd3+/CD8+ 0.979 1.13-16.585-60.361 27.191 Figure 3. Doble Platform versus Stepcount to CD3+/CD8+ cells COEFFICIENT (R 2 ) SLOPE Y- INTERCEPT 95% LOWER 95% UPPER CD3+ 0.978 1.03 23.606-32.820 80.032 CD3+/CD4+ 0.975 1.11-2.10-28.429 24.113 CD3+/CD8+ 0.979 1.13-16.585-60.361 27.191 Reproducibility: The reproducibility study was performed using three samples with content in lymphocyte high, medium and low respectively and testing each one in 10 different tubes. Subset Mean Dev. Tip. Maxim. Minim. N total CD3 136,80 24,38 174 101 10 Low CD4 38,40 6,20 45 25 10 CD8 84,00 14,91 105 66 10 CD3 2846,30 248,55 3159 2411 10 High CD4 1598,20 169,72 1867 1340 10 CD8 938,20 79,54 1051 802 10 CD3 400,00 35,64 467 344 10 Medium CD4 139,90 20,83 162 105 10 CD8 224,00 21,81 269 185 10 Figure 1. Doble Platform versus Stepcount to CD3+ cells Sensitivity or linearity: To perform the sensitivity study, acquired a different number of beads for the same sample and calculate the number of Cells CD3+. The sample was a peripheral blood of an individual without hematologic diseases diagnosed. Figure 2. Doble Platform versus Stepcount to CD3+/CD4+ cells

PEARSON R2 SIGINIFICANCE OF LEVEL CD3+ 0.998 0.996 0.01 Comparison with the reference product in the market (Trucount, BD): Not for resale. Immunostep will not be held responsible for patent infringement or other violations that may occur with the use of our products. Statistical event. CD34+ (External clinical site) event. CD34+ (Stepcount) N Valid 17 17 Missing 0 0 Mean 1368,2353 1469,7388 Median 600,0000 599,27 Variance 3428498,261 3907456,955 Dev. Tip. 1851,62044 1976,72885 Minimum 21,40 22,51 Maximum 6558,00 6755,68 Percentile 25 90,3000 120,5550 50 600,0000 508,5200 75 2961,0000 3122,6350 Precision studies were performed comparing the results obtained from an external reference haematological department. For each sample two aliquots were made. The samples include both, leukapheresis and bone marrow sample from human donors. References. 1. Frank Mandy, Bruno Brando. Enumeration of Absolute Cell Counts Using Immunophenotypic Techniques. Current Protocols in Cytometry. May 2001 2. Bruno Brando, Wolfgang Göhde, Jr. The Vanishing Counting Bead Phenomenon: Effect on Absolute CD34 Cell Counting in Phosphate-Buffered Saline-Diluted Leukapheresis Samples. Cytometry 43:154 160 (2001). 3. Jackson AL, Warner NL. Preparation, staining, and analysis by flow cytometry of peripheral blood leukocytes. In: Rose NR, Friedman H, Fahey JL, eds. Manual of Clinical Laboratory Immunology.3rd ed. Washington, DC: American Society for Microbiology; 1986:226-235

Troubleshooting guide. PROBLEM SOLUTION Bead are not detected in the FSC/SSC dot plot. 1. Decrease the threshold until the bead population appears. 2. Increase the value of FSC We can not clearly distinguish the population of areas 1. Re-adding the lysis solution and allow more time to be sure that the tube has a transparent red color 2. Remove cellular debris by a gate in the region that shows the image 3. Identify the bead region in other fluorescence