CODE/NAME ENCL CODE/NAME ENCL



Similar documents
Peach Bottom Atomic Power Station, Units 2 and 3 Renewed Facility Operating License Nos. DPR-44 and DPR-56 NRC Docket Nos.

Nuclear Safety Council Instruction number IS- 23 on in-service inspection at nuclear power plants

MATERIALS LICENSE. 1. American Centrifuge Operating, LLC 3. License Number: SNM-2011, Amendment 4

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C June 26, 2014

MATERIALS LICENSE. 1. Honeywell International, Inc. 3. License Number: SUB-526, Amendment 6-1

Supporting New Build and Nuclear Manufacturing in South Africa

This occurrence is considered to be of no significance with respect to the health and safety of the public.

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION WASHINGTON, D.C June 1, 2005

Part 1 General and Administrative Information. Part 3 Applicant s Environmental Report Combined License Stage

2. ASTM Standard E , "Standard Practice for Conducting Surveillance Tests for Light-Water Cooled Nuclear Power Reactor Vessels".

Response to NRC Request for Additional Information for the Review of the Fermi 2 License Renewal Application - Set 37

Qualification of In-service Inspections of NPP Primary Circuit Components

Oil and Coolant Circulating Heating System. Model - OCSM

1J,4Zc6 * CONNECTICUT YANKEE ATOMIC POWER COMPANY HADDAM NECK PLANT 362 INJUN HOLLOW ROAD - EAST HAMPTON, CT

Spicer Axles & Brakes ABIB-0302

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Wilfred C. LaRochelle Principal Nuclear Consultant HSB Global Standards, USA

March 5, 2015 NUCLEAR FUEL SERVICES, INC., LICENSEE PERFORMANCE REVIEW (NUCLEAR REGULATORY COMMISSION INSPECTION REPORT / )

Instructions cover both:

Office for Nuclear Regulation

Sara Brock Counsel for NRC Staff

NORTH CAROLINA EASTERN MUNICIPAL POWER AGENCY SHEARON HARRIS NUCLEAR POWER PLANT, UNIT 1. Renewed License No. NPF-63

Itemized RAI Responses

MATERIALS LICENSE. Delaware City, Delaware Docket No Reference No.

NUCLEAR REGULATORY COMMISSION [EA ; NRC ] In the Matter of Northern States Power Company, Minnesota

This instruction is valid for all ACD pump models shown on page 2

3. Design of Structures, Components,

U.S. NUCLEAR REGULATORY COMMISSION STANDARD REVIEW PLAN OFFICE OF NUCLEAR REACTOR REGULATION

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

In Reference 3, the RAI includes two questions for which responses are provided in Attachment 1.

APPENDIX B SUPPLEMENTAL INSPECTION PROGRAM A. OBJECTIVES AND PHILOSOPHY OF THE SUPPLEMENTAL INSPECTION PROGRAM


Fire Hydrant Troubleshooting

REGULATORY GUIDE 5.29 (Draft was issued as DG 5028, dated May 2012) SPECIAL NUCLEAR MATERIAL CONTROL AND ACCOUNTING SYSTEMS FOR NUCLEAR POWER PLANTS

RMF Engineering

Salof Companies Modularized Gas Liquefaction Plants

Quick Connect Boxes Inside Gloveboxes

Standard Hydraulic Piping Flushing Procedure

The Axial Flow Valve. Class 300/ SERIES

UX-30 PERFORMANCE TESTING SUMMARY REPORT Revision 0

TO TEST OR NOT TO TEST: A COMPARISON OF THE PRESSURE TESTING REQUIREMENTS BETWEEN ASME B31.3 AND ASME SECTION VIII, DIVISION 1

James M. Pleasants Company

The ACR : Advanced Design Features for a Short Construction Schedule

ASME B31.3 Process Piping. Scope of B31.3 Course

The Problem Solving of Exhaust Frame Air Cooling System Pressure Low in GE Frame 9 Gas Turbine

Published in the Official State Gazette (BOE) number 166 of July 10th 2009 [1]

CEP Discussion: AREVA s SONGS-Specific Used Fuel Solution

Crystal River Unit 3 License Transfer Notification of Transfer Date

Pressure Vessel Assessment Report

Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative

u gust 23, 1983 Sincerely, Original signed by: Kenneth T. Eccleston, Project Manager Operating Reactors Branch #2 Division of Licensing

*Specify Oversize When Ordering

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

BODY OF KNOWLEDGE API-570 AUTHORIZED PIPING INSPECTOR CERTIFICATION EXAMINATION

Service Bulletin No. SB MANDATORY SERVICE BULLETIN. Safetying of standard and flop-type fuel pickup tubes.

This document is the property of and contains Proprietary Information owned by Westinghouse Electric Company LLC and/or its subcontractors and

NRC REGULATORY ISSUE SUMMARY , REQUESTING QUALITY ASSURANCE PROGRAM APPROVAL RENEWALS ONLINE BY ELECTRONIC INFORMATION EXCHANGE

Regulatory Guide Verification, Validation, Reviews, And Audits For Digital Computer Software Used in Safety Systems of Nuclear Power Plants

TABLE OF CONTENT

Maintenance and Service Instruction

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION OFFICE OF NEW REACTORS WASHINGTON, DC

Heater Replacement Procedure

July 31, Dear Dr. Biegalski:

To: All Shipowners, Ship Managers, Ship Masters and Classification Societies

APPENDIX 2-3 PCAPP EDS INSPECTION LOG SHEETS

Summary of NRC s Review of the Recent Security Issues at the Shearon Harris Nuclear Plant

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Owner-User Pressure Equipment Integrity Management Requirements

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

2005 MINI Cooper MANUAL TRANSMISSIONS On-Vehicle Servicing. Cooper S Getrag 285

NUCLEAR POWER PLANT PRESSURE EQUIPMENT

Boiler & Pressure Vessel Inspection discrepancies and failures

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items

BOWIE PUMPS OPERATION - MAINTENANCE

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C November 13, 2012

Boiling Water Reactor Systems

Ozone Generator Manual

Transcription:

CATEGORY REGULORY INFORMATION DISTRIBUTi SYSTEM (RIDS) ACCESSION NBR:9804140321 DOC.DATE: 98/04/06 NOTARIZED: NO DOCKET # FACIL:50-269 Oconee Nuclear Station, Unit 1, Duke Power Co. 05000269 50-270 '0conee Nuclear Station, Unit 2, Duke Power Co. 05000270 #-=l0-2871oconee Nuclear Station, Unit 3, Duke Power Co. 05000287 50-369 William B. McGuire Nuclear Station, Unit 1, Duke Powe 05000369 50-370 William B. McGuire Nuclear Station, Unit 2, Duke Powe 05000370 50-413 Catawba Nuclear Station, Unit 1, Duke Power Co. 05000413 50-414 Catawba Nuclear Station, Unit 2, Duke Power Co. 05000414 AUTH.NAME AUTHOR AFFILIATION c TUCKMAN,M.S. RECIP.NAME Duke Power Co. RECIPIENT AFFILIATION Document Control Branch (Document Control Desk) SUBJECT: Requests relief from requirements of ASME Boiler & Pressure Vessel Code,Section XI,Subsection IWE,1992 Edition w/1992 addenda for Oconee Units 1,2 & 3,McGuire Units 1 & 2 & Catawba Units 1 & 2. T E G DISTRIBUTION CODE: A047D COPIES RECEIVED:LTR ENCL SIZE: 0 TITLE: OR Submittal: Inservice/Testing/Relief from ASME Code - GL- 9-04 NOTES: R RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-2 LA 1 1 PD2-2 PD 1 1 LABARGE,D 1 1 RINALDI,F 1 1 TAM,P. 1 1 INTERNAL: ACRS 1 1 AEOD/SPD/RAB 1 1 F-E *ENTER 01 1 1 NRR/DE/EMEB 1 1 4 NUBOCSP1ABSTRAC1 1 OGC/HDS2 1 0. S/DET/EIB 1 1 RES/DET/EMMEB 1 1 EXTERNAL: LITCO ANDERSON 1 1 NOAC 1 1 C NRC PDR 1 1 u M E N T NOTE TO ALL "RIDS" RECIPIENTS: PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD) ON EXTENSION 415-2083 TOTAL NUMBER OF COPIES REQUIRED: LTTR 16 ENCL 15

3Duke Pl OWe A Duke EnegCompany M. S. Tuckman Executive Vice President Nuclear Generation Duke Power Company A Duke Energy Company ECO7H 526 South Church Street P.O. Box 1006 Charlotte, NC 28201-1006 (704) 382-2200 OFFICE (704) 382-4360 FAX April 6, 1998 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 ATTENTION: SUBJECT: Document Control Desk Duke Energy Corporation Oconee Nuclear Station - Units 1, 2, & 3 Docket Nos. 50-269, 50-270, and 50-287 McGuire Nuclear Station - Units 1 & 2 Docket Nos. 50-369 and 50-370 Catawba Nuclear Station - Units 1 & 2 Docket Nos. 50-413 and 50-414,Request for Relief from Requirements of the ASME Boiler and Pressure Vessel Code, Section XI in Accordance With 10 CFR 50.55a(a)(3)(ii) Duke Energy Corporation Serial Number 98-GO-001 Pursuant to 10 CFR 50.55a(a)(3)(ii), Duke Energy Corporation requests relief from the requirements of the ASME Boiler and Pressure Vessel Code, Section XI, Subsection IWE, 1992 Edition with the 1992 Addenda for Oconee Units 1, 2 and 3, McGuire Units 1 and 2, and Catawba Units 1 and 2. Specifically, this request is for relief from the visual, VT-3 examination requirements for seals and gaskets of Class MC pressure retaining components and metallic liners of Class CC components, as specified in the ASME Boiler and Pressure Vessel Code, Section XI, 1992 Edition with the 1992 Addenda, IWE-2500, Table IWE-2500-1, for Examination Category E-D, Item Numbers E5.10 and E5.20. A detailed relief request, including a background discussion and justification is included as an enclosure to this letter. Duke requests timely NRC review and approval of this relief request so that Containment Inservice Inspection Plans, which are under development, can be completed to support the 9804140321 980406 PDR ADOCK 05000269 G PDR

U. S. Nuclear Regulatory Commission April 6, 1998 'Page.2 implementation of Containment Inservice Inspections during plant refueling outages starting in September, 1998. A NRC response is requested by July 1, 1998 in order to allow sufficient time to amend the Duke plans that will implement this request. Questions regarding this request should be directed to J. S. Warren at (704) 382-4986. Very truly yours, M. S. Tuckman MST/JSW Attachment: Duke Energy Corporation Request for Relief Serial Number 98-GO-001, Pages 1 through 7. xc w/att: L. A. Reyes, Regional Administrator U.S. Nuclear Regulatory Commission, Region II Atlanta Federal Center 61 Forsyth St., SWW, Suite 23T85 Atlanta, GA 30303 D. E. Labarge, NRC Project Manager (ONS) U. S. Nuclear Regulatory Commission Mail Stop 0-14 H25 Washington, DC 20555-0001 F. Rinaldi, NRC Project Manager (MNS) U. S. Nuclear Regulatory Commission Mail Stop 0-14 H25 Washington, DC 20555-0001 P. S. Tam, NRC Project Manager (CNS) U. S. Nuclear Regulatory Commission Mail Stop 0-14 H25 Washington, DC 20555-0001 M. A. Scott, NRC Senior Resident Inspector (ONS) D. J. Roberts, NRC Senior Resident Inspector (CNS) S. M. Shaeffer, NRC Senior Resident Inspector (MNS)

U. S. Nuclear Regulatory Commission April 6, 1998 Page 3 bxc w/att: L. A. Keller J. E. Burchfield M. T. Cash K. L. Crane M. S. Kitlan D. B. Mayes K. E. Nicholson J. 0. Barbour D. E. DeMart J. S. Warren M. J. Ferlisi R. V. Hester W. E. Shaban H. 0. Nekooasl T. J. Coleman R. Branch T. E. Hawkins NRIA File/ELL

SeriaPNo. 98-GO-001 Page 1 of 7 Attachment DUKE ENERGY CORPORATION Oconee Nuclear Station Units 1, 2 and 3 McGuire Nuclear Station Units 1 and 2 Catawba Nuclear Station Units 1 and 2 Request for Relief from the Requirements of the ASME Boiler and Pressure Vessel Code, Section XI Background: Pursuant to 10 CFR 50.55a (a) (3) (ii), Duke Energy Corporation requests relief from the requirements of the ASME Boiler and Pressure Vessel Code, Section XI, Subsection IWE, 1992 Edition with the 1992 Addenda for Oconee Units 1, 2 and 3, McGuire Units 1 and 2, and Catawba Units 1 and 2. Visual VT-3 examination of seals and gaskets on airlocks, equipment hatches and other devices required to assure containment leak-tight integrity is required in accordance with Subsection IWE, IWE-2500, Table IWE-2500-1, Examination Category E-D, Items E5.10 and E5.20. Duke Energy Corporation believes that these visual examinations are impractical and that compliance with the specified requirements of Subsection IWE would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety. Duke Energy Corporation believes that existing surveillance requirements are sufficient to assure the leak-tight integrity of containment pressure retaining seals and gaskets. I. System/Component(s) for Which Relief is Requested: Seals and gaskets of Class MC pressure retaining components and metallic liners of Class CC components, Examination Category E-D, Item Numbers E5.10 and E5.20 of IWE-2500, Table IWE-2500-1, ASME Section XI, 1992 Edition, 1992 Addenda. II. Code Requirement(s): IWE-2500, Table IWE-2500-1 requires seals and gaskets on airlocks, hatches, and other devices required to

Seria No. 98-GO-001 Page 2 of 7 assure containment leak-tight integrity to be visually. examined, VT-3, once each interval. III. Code Requirement from which Relief is Requested: Relief is requested from performing the Code required visual examination, VT-3, on the above identified metal containment seals and gaskets. IV. Basis for Requesting Relief: Duke Energy Corporation has determined that the following types of containment penetrations have seals and gaskets which may be subject to the requirements of IWE-2500, Table IWE-2500-1, Examination Category E-D. A description of these penetrations and their seals and gaskets is provided below. 1.Electrical Penetrations D.G. O'Brien electrical penetration assemblies use a header plate (blind flange) bolted to a containment penetration nozzle flange and are sealed with redundant metal O-rings between the flange faces. Modules through which electrical conductors pass are welded to both sides of the header plate, and non-resilient hermetic glass seals are used within each module to seal individual electrical conductors which pass through. All of the header plate openings are interconnected by a series of channels within the header plate to facilitate local leak rate (Type B) testing. The dual O-ring configuration also allows for local leak rate testing to be performed. Conax electrical penetration assemblies consist of one of the two following types: * One type uses a header plate which is welded to a containment penetration sleeve. Electrical conductors are routed through modules which penetrate the header plate. The module connection to the header plate is sealed by compression fittings (ferrules) which compress seal material against the header plate. Midlock plugs are used to compress ferrules onto the header plate to seal spare openings.

Seria No. 98-GO-001 Page 3 of 7 Individual conductors are routed through the modules, and the ends of each module contain a resilient seal surrounding the conductors to maintain leak-tightness. A port in each module is aligned between the ferrules within the header plate opening, and all of the header plate openings are interconnected by a series of channels to facilitate local leak rate (Type B) testing. * The second type uses a header plate (blind flange) which is bolted to a containment penetration nozzle flange and is sealed with redundant metal O-rings between the flange faces. The remaining details are similar to the first Conax type, and interconnected channels and the dual O-rings are provided to facilitate local leak rate (Type B) testing. Viking electrical penetration assemblies use a header plate (blind flange) bolted to a containment penetration nozzle flange and are sealed with redundant metal O-rings between the flange faces. Modules through which electrical conductors pass are sealed to the header plate, and the modules are also sealed against a second header plate within the penetration assembly. The space between the header plates is configured to facilitate local leak rate (Type B) testing to verify the integrity of the module and conductor seals. The dual O-ring configuration also facilitates local leak rate (Type B) testing. 2. Mechanical Penetrations with Bolted Joints Containment penetrations such as fuel transfer tube penetrations and some spare penetrations consist of bolted, flanged joints with gaskets or O-rings. These penetrations are designed to permit local leak-rate testing in accordance with 10CFR50, Appendix J to verify the integrity of the sealed or gasketed connection. 3. Equipment Hatches and Personnel Air Locks (including Emergency Personnel Air Locks at Oconee) * Equipment Hatches utilize dual O-rings to seal the hatch cover to the Equipment Hatch penetration. The sealed joint is designed to

Seria No. 98-GO-001 Page 4 of 7 permit local leak-rate testing in accordance with 10CFR50, Appendix J after each closure, before returning to service. * Personnel and Emergency Personnel Airlocks utilize an inner and outer door with dual gaskets or seals on each door to seal the airlock doors to the bulkheads on the containment penetrations. The airlocks also contain other gaskets and seals, such as those for sealing handwheel shafts, electrical penetrations, blank flanges, and equalizing pressure connections. The sealed joints on airlocks are designed to permit local leak-rate testing in accordance with 10CFR50, Appendix J and Technical Specifications. Leak-tightness of containment pressure retaining seals and gaskets is verified by Type B tests in accordance with Option A of 10 CFR 50, Appendix J, as required by current Technical Specifications. On some electrical penetrations, internal compartments within the electrical penetration assembly are pressurized by N 2 or SF 6 gas, and the integrity of seals on these penetration compartments is verified by monitoring the gas pressure and determining the local leak rate to satisfy the Type B test requirements. Overall containment leakage is verified by Type A tests in accordance with Option B of 10 CFR 50, Appendix J. Although the Type A test does not verify individual penetration leakage, it does provide additional assurance that there is no significant leakage through the containment pressure boundary, which includes all sealed penetrations. Examination of seals and gaskets would require the joints, which are proven adequate by pressure testing, to be disassembled. For electrical penetrations, this would involve determination of cables at electrical penetrations if enough cable slack is not available, disassembly of the joint, removal and examination of the seals and gaskets, re-assembly of the joint, re termination of the cables if necessary, post maintenance testing of the cables, and a post maintenance Appendix J test of the penetration. This imposes the risk that equipment could be damaged, thus increasing the risk of potential leakage. The 1992 Edition, 1993 Addenda, of Section XI recognizes that disassembly of joints to perform these examinations is

Seria No. 98-GO-001 Page 5 of 7 not warranted and Examination Category E-D was modified to state that sealed and gasketed connections need not be disassembled solely for performance of examinations. However, without disassembly, most of the surface of the seals and gaskets would be inaccessible for visual examination. A visual examination of the seal or gasket will not ensure that the material is acceptable and that it will effectively seal the joint. This can only be determined by pressure testing, which is already required by 10 CFR 50, Appendix J. In addition, visual examinations on existing seals and gaskets after joint disassembly provides no benefit as most of these are replaced prior to joint reassembly. For those penetrations that are routinely disassembled, a Type B test is required upon final assembly and prior to service. Since the Type B test will assure the leak tight integrity of primary containment, the performance of the visual examination would not increase the level of safety or quality. If an unacceptable leakage rate is determined by Type B testing after the connection is reassembled, corrective measures would be taken and the component would be retested to ensure leak tightness. The visual, VT-3 examinations required by Subsection IWE for some seals on penetrations such as the fuel transfer tube will increase personnel radiological exposure, with no compensating increase in quality or safety. Recently approved revisions to ASME Section XI, Subsection IWE have eliminated the visual examination VT-3 of seals and gaskets for many of the reasons described above. Although not yet published, these changes are expected in the next scheduled publication of the Code (1998 Edition). Examination of containment accessible surfaces performed in accordance with the ASME Code, Section XI, IWE-2500, Table IWE-2500-1, Examination Category E-A may reveal indications of damage or degradation if it occurs on or adjacent to containment sealed or gasketed connections. If such degradation is detected, the provisions of 10 CFR 50.55a (b)(2)(x)(a) will require that an evaluation be performed to determine the acceptability of adjacent inaccessible areas, including the sealed or gasketed joint. In such cases, this evaluation may require that the connection be disassembled and examined, or may require that the

SeriaPNo. 98-GO-001 Page 6 of 7 connection be leak tested to provide continued assurance of the integrity of these seals or gaskets. Relief is requested in accordance with 10 CFR 50.55a (a)(3)(ii). Compliance with the specified requirements of this section would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety. Testing the seals and gaskets in accordance with 10 CFR 50, Appendix J will provide adequate assurance of the leak-tight integrity of containment pressure retaining seals and gaskets. V. Alternative Examination(s): The leak-tightness of containment pressure retaining seals and gaskets will be verified by leak rate testing in accordance with 10 CFR 50, Appendix J, as required by Technical Specifications. No additional alternatives to the visual, VT-3 examinations required in Table IWE-2500-1, Examination Category E-D, for Items E5.10 and E5.20 will be performed. VI. Justification for the Granting of Relief: ASME Section XI, 1992 Edition, 1992 Addenda, Table IWE 2500-1, Examination Category E-D, requires visual examination (VT-3) of containment seals and gaskets. Examination of most seals and gaskets require the joints, which are proven adequate through Appendix J testing, to be disassembled. This results in a hardship or unusual difficulty without a compensating increase in the level of quality and safety for those joints which are not routinely disassembled. For sealed or gasketed joints which are routinely disassembled, the VT-3 visual examination provides little or no benefit and results in a hardship or unusual difficulty without a compensating increase in the level of quality and safety because most seals and gaskets are replaced when the joint is disassembled, and all joints are subject to local leak rate testing after reassembly. VT-3 visual examinations of seals and gaskets do not ensure that these items, when reinstalled, will not leak. Also, the additional personnel radiological exposure for performance of some seal examinations is not justified, given the fact that the visual

Serial No. 98-GO-001 Page 7 of 7 examinations do not verify leak tightness. Leak rate testing in accordance with 10 CFR 50, Appendix J is sufficient to provide this assurance for all containment pressure retaining seals and gaskets. Conditions observed on accessible surfaces of sealed or gasketed joints during the performance of the visual examinations required by the ASME Code, Section XI, 1992 Edition, 1992 Addenda, Table IWE-2500-1, Examination Category E-A which may indicate the presence of an unacceptable condition on inaccessible surfaces of sealed or gasketed joints shall be subject to the requirements of 10 CFR 50.55a (b)(2)(x)(a). This provision of 10 CFR 50.55a is sufficient to invoke appropriate visual examinations of sealed or gasketed joints when warranted. No other visual examinations of seals or gaskets are necessary to ensure containment leak tight integrity. VII. Implementation Schedule First inspection interval for IWE. Evaluated By: r Date: :-/% 9k Reviewed By: Date: / 3-11-9g