Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5



Similar documents
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Technical Data. Dimensions

Technical Data. Dimensions

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Electronic Pressure Switch EDS 300

BOS 73K... BOS 74K...

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Inductive sensor NI10-M18-Y1X-H1141

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Liquid Level Limit Switch liquiphant T FTL 20

How To Make An Ultrasonic Sensor

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Instruction Manual Service Program ULTRA-PROG-IR

RS - SPM. Serial parallel translator module

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

TECHNICAL DATASHEET Incremental Encoder RI 58-H

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Color Mark Sensor with Red or Green LED E3S-VS

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Electronic Pressure Switch EDS 3000

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

TECHNICAL DATASHEET Incremental Encoder RI 80-E

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

crm+25/d/tc/e Extract from our online catalogue: Current to:

Capacitive Prox E2K-X

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Smart Sensing Solutions Since 1954

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

intelligent solutions

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

General 1-2-Opto-electronics Safety Switches 4-Emergency

LED...A Q Series Sealed High-Intensity

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Conductive Level Switch FK 2 Technical Data:

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Proportional pressure regulators VPPE

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Magnetic Proximity Switches Series CST - CSV and CSH

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

is then retained absolutely without interruption.

Variable Preset Counter signo 723.1

MasterINTERFACE 39 Series - Relay interface modules

REGTRONIC OPERATING INSTRUCTIONS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

ACS-30-EU-EMDR-10-MOD

PCS0100en Persy Control Services B.V. Netherlands

INSTRUCTION MANUAL for UNIBLITZ MODEL DM412 SHUTTER DRIVE MODULE

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Product and functional description

crm+130/iu/tc/e Extract from our online catalogue: Current to:

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Combi switchbox with integrated 3/2 way pilot valve

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Combi B Alarm box. Mounting instructions

Series 7500 Torque Sensor

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

MasterINTERFACE 39 Series - Relay interface modules

Relative and absolute pressure switch type 529

W150: Miniature photoelectric switch series with completely integrated electronics

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Digital Keypad Use s Manual

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

technical data (according to IEC )

TMS TANK MANAGEMENT SYSTEM

Digital input modules

WEB log. Device connection plans

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

W 27-2: The photoelectric switch series with expanded possibilities

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Electrical connection

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Shunt lock function 3066

Duct Humidity Transmitter

CLV 41x Bar Code Scanner Standard line

Preset Counter signo 721

Magnetic proximity switches

ATL Fuel Level Sender Probes

DALI RC BASIC SO. Control unit Operating instructions

Transcription:

Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis mode selectable Window mode selectable Synchronization options Adjustable acoustic power and sensitivity Temperature compensation Diagrams Characteristic response curve Distance Y [m] 0.6 0. 0. 0.0-0. -0. -0.6-0.8 0.0 0..0..0..0..0 Y Distance X [m] X Curve : flat surface 00 mm x 00 mm Curve : round bar, Ø mm Technical data General specifications Sensing range Adjustment range Dead band Standard target plate Transducer frequency Response delay Indicators/operating means green 80... 000 mm 0... 000 mm 0... 80 mm 00 mm x 00 mm approx. 80 khz 6 ms minimum 9 ms factory setting solid: Power-on flashing: Standby mode or program function object detected yellow solid: switching state switch output flashing: program function yellow solid: switching state switch output flashing: program function red solid: temperature/program plug not connected flashing: fault or program function object not detected Temperature/TEACH-IN connector Temperature compensation, Switch points programming, output function setting Electrical specifications Operating voltage U B 0... 0 V DC, ripple 0 % SS No-load supply current I 0 0 ma Interface Interface type RS, 9600 Bit/s, no parity, 8 data bits, stop bit Input/Output Synchronization bi-directional 0 level -U B...+ V level: + V...+U B input impedance: > KOhm synchronization pulse: 00 µs, synchronization interpulse period: ms Synchronization frequency Common mode operation 0 Hz Multiplex operation 0 Hz / n, n = number of sensors, n Output Output type switch outputs PNP, NO/NC, programmable Rated operating current I e 00 ma, short-circuit/overload protected Voltage drop U d. V Repeat accuracy 0. % of full-scale value Switching frequency f. Hz Range hysteresis H % of the adjusted operating range (default settings), programmable Temperature influence % from full-scale value (with temperature compensation) 0. %/K (without temperature compensation) Ambient conditions Ambient temperature -... 70 C (-... 8 F) Storage temperature -0... 8 C (-0... 8 F) Mechanical specifications Connection type Connector M x, -pin Degree of protection IP6 Material Housing stainless steel (.0 / AISI 0) PBT plastic parts Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam Mass 0 g Factory settings Output Switching point: 00 mm output function: Switch point operation mode output behavior: NO contact Output Switching point: 000 mm output function: Switch point operation mode output behavior: NO contact Compliance with standards and directives Standard conformity Standards EN 6097--:007 + A:0 IEC 6097--:007 + A:0 Approvals and certificates UL approval culus Listed, General Purpose CSA approval ccsaus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 6 V

Dimensions M0 x. Additional Information Possible operating modes. Switch point mode When A < A, both switch outputs are activated as N.O. contacts. A (N.O.) Switch point Switch point A (N.O.) 6 Temperature probe Coded plug 9 7. When A > A, both switch outputs are activated as N.C. contacts. A (N.C.) A (N.C.). Window mode To exchange the switching distances is of no effect. A (N.O.) A (N.C.). Latching mode To exchange the switching distances is of no effect. A (N.O.) A (N.C.) Electrical Connection Standard symbol/connection: (version E6, pnp) (BN) (GY) (WH) (BK) (BU) + UB Sync. - UB Core colors in accordance with EN 6097--. Pinout Wire colors in accordance with EN 6097-- BN WH BU BK GY (brown) (white) (blue) (black) (gray)

Accessories BF 0 Mounting flange, 0 mm BF 0-F Mounting flange with dead stop, 0 mm BF -0 Universal mounting bracket for cylindrical sensors with a diameter of... 0 mm UVW90-M0 Ultrasonic -deflector UVW90-K0 Ultrasonic -deflector UC-0GM-PROG ULTRA000 Software for ultrasonic sensors, comfort line UC-0GM-R V-G-M-PVC Female cordset, M, -pin, PVC cable Description of Sensor Functions Programming procedure The sensor features programmable switch outputs with programmable switch points. Programming the switch points and the operating mode is done either via the sensors RS interface and the ULTRA 000 software (see the ULTRA 000 software description) or by means of the programming plug at the sensors rear end which is described here. Programming switch points and. Disconnect supply voltage. Remove the programming plug to activate program mode.. Reconnect supply voltage (Reset) A. Place the target at the desired switch point position for A. Momentarily insert the programming plug in position A and then remove. This will program the switch point A. 6. Place the target at the desired switch point position for A A E/E 7. Momentarily insert the programming plug in position A and then remove. This will program the switch point A. T Coded plug Notes: Removing the programming plug saves the new switch point position into the device memory. The programming status is indicated by the. A flashing green indicates that the target is detected; a flashing red indicates that no target is detected. Programming the operation mode If the program mode is still activated, continue at number. If not, activate program mode by performing the sequence numbers to.. Disconnect supply voltage. Remove the programming plug to activate program mode.. Reconnect supply voltage (Reset). Insert the programming plug in position E/E. By removing and reinserting the plug, the user can toggle through the three different modes of operation. The selected mode is indicated by the s as shown below: Switch point mode, A flashes Window mode, A flashes Latching mode, s A and A flash. ce the desired mode is selected, insert the programming plug in position T. This completes the programming procedure and saves the switch points and mode of operation. 6. The sensor now operates in normal mode. The programming plug also functions as the temperature compensation. If the programming plug has not been inserted in the T position within minutes, the sensor will return to normal operating mode with the latest saved values, without temperature compensation. Factory settings See technical data. Display The sensor provides s to indicate various conditions.

# During Normal Operation - Temperature compensated - with removed programming plug Interference (e.g. compressed air) During Sensor Programming Switch point A: Object detected No object detected Switch Point A: Object detected No object detected Operation mode: Switch point mode Window mode Latching mode Green Red Yellow A Yellow A Switching state A Switching state A Switching state A Switching state A remains in previous state ous remains in previ- state Standby previous state previous state yellow Dual- green/red yellow E E A A "Power on"/disturbance Synchronization This sensor features a synchronization input for suppressing ultrasonic mutual interference ("cross talk"). If this input is not connected, the sensor will operate using internally generated clock pulses. It can be synchronized by applying an external square wave. The pulse duration must be 00 µs. Each falling edge of the synchronization pulse triggers transmission of a single ultrasonic pulse. If the synchronization signal remains low for second, the sensor will revert to normal operating mode. Normal operating mode can also be activated by opening the signal connection to the synchronization input (see note below). If the synchronization input goes to a high level for > second, the sensor will switch to standby mode, indicated by the green. In this mode, the outputs will remain in the last valid output state. If the option for synchronization is not used, the synchronization input has to be connected to ground (0 V) or the sensor must be operated via a V cordset (-pin). The synchronization function cannot be activated during programming mode and vice versa. The following synchronization modes are possible:. Several sensors (max. number see technical data) can be synchronized together by interconnecting their respective synchronization inputs. In this case, each sensor alternately transmits ultrasonic pulses in a self multiplexing mode. No two sensors will transmit pulses at the same time (see note below).. Multiple sensors can be controlled by the same external synchronization signal. In this mode the sensors are triggered in parallel and are synchronized by a common external synchronization pulse.. A separate synchronization pulse can be sent to each individual sensor. In this mode the sensors operate in external multiplex mode (see note below).. A high level (+U B ) on the synchronization input switches the sensor to standby mode. Sensor response times will increase proportionally to the number of sensors that are in the synchronization string. This is a result of the multiplexing of the ultrasonic transmit and receive signal and the resulting increase in the measurement cycle time. Note on communication with the UC-0GM-R interface cable The UC-0GM-R interface cable allows for communication with the ultrasonic sensor using ULTRA000 software. The cable creates a connection between a PC RS- interface and the programming plug socket on the sensor. When connecting to the sensor, make certain the plug is lined up correctly; otherwise no communication will be possible. The key of the cable s plug must be aligned to the groove of the socket on the sensor (not with the arrow symbol on the sensor). Programmable parameters with the ULTRA000 software Switch point and NO/NC function Operation mode Sonic speed RS -connection Groove Temperature/program connector (PC connection via interface cable UC-0GM-R) : TXD : RXD : not used : GND Temperature offset (The inherent temperature-rise of the sensor can be considered in the temperature compensation) Expansion of the unusable area (for suppression of unusable area echoes) Reduction of the detection range (for suppression of remote range echoes) Time of measuring cycle Acoustic power (interference of the burst duration) Sensitivity Behaviour of the sensor in case of echo loss Behaviour of the sensor in case of a fault Average formation via an allowed number of measuring cycles /off-delay Switching hysteresis Selection of the parameter set, RS or manually V-plug connector (Mx) -window

When connected to a PC and running the ULTRA000 software, the sensor can act as a long term data logger as well. Mounting conditions If the sensor is installed in places where the operating temperature can fall below 0 C, the BF0, BF0-F or BF -0 fixing clamp must be used.