SAGEON SITE MONITOR (SSM) Application Note AN103-4012-00



Similar documents
UPS Applications and VRLA Battery Sizing

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

InHome Water Leak Detection Package

SiteRanger tm. Power quality / site monitoring. Comm/net Systems, Inc.

Technical Guide for SageView Screens & Menus

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Model: DC-A2IO Advanced HVAC Controller

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Real-Time Vehicle Tracking System [RKI-1660]

USB Plus+ RFID Reader Setup Guide

Temperature & Humidity SMS Alert Controller

REMOTE MONITORING SYSTEM MATURE FIELDS UNCONVENTIONALS MONITORING SYSTEM. Solving challenges.

About Your NetBotz 4-20mA Sensor Pod

SMART SENSOR COLLECTION

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Pipeliner CRM Phaenomena Guide Sales Pipeline Management Pipelinersales Inc.

Application/Connection Examples

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SMS GSM Alarm Messenger

Fire Pump Controllers Remote Alarm Panels

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

LIFT CONTROL SYSTEMS CATALOGUE 2007

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Real-time Vehicle Tracking System

Self Help Guides. Setup Exchange with Outlook

Video Splitter VS-104 / VS-108 User's Manual

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Introduction To SCADA and Telemetry

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

ROC800-Series Advanced Pulse Module

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

Automatic start of a generator

SUPPORT GUIDE FOR SETTINGS IN NOKIA 6600 IMAGING PHONE

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Advantium 2 Plus Alarm

SWITCHGEAR. EGP Switchgear

Inverter / Charger Installation General Operations and AC and DC Connections

Current Loop Application Note 1495

Self Monitoring Power Supply (BPSM)

Using installed Fieldbus Wiring to carry Ethernet Communications

VPCCCare. Virtual PC Center Service Warranty Program

Digital and Analog I/O

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

Allen-Bradley/Rockwell

Automatic Transfer Switch Controller


Application Note Gemalto Access Client for windows smart card and EFS on Microsoft Windows Vista

Transponder for GainMaker Amplifiers

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

EDI Distributor Control Interface Wiring and Setup Instructions

PagePac PAGEPAL V

TN0023 Technical note

LIFT CONTROL SYSTEMS CATALOGUE 2007

LAN API FOR DOORBIRD AND BIRDGUARD

SCADA and Monitoring for Solar Energy Plant

ACTURA V DC, 3-40 kw, A. The Regional DC power system with Global Muscle

Low Power FM Site Monitoring Kit

PRODUCT LIST Facility DDC Access WebXL DDC

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

BEIJING EPSOLAR TECHNOLOGY CO.,LTD.

WIRELESS MAGNETIC CONTACT

How To Use A Watt Saver On A Microcontroller (Watt Saver) On A Cell Phone Or Mp3 Player

StatusScope Remote Monitoring Service. Mobile User Guide

INTREPID Perimeter Intrusion Detection System

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Self Help Guides. Create a New User in a Domain

Web-Based Remote Monitoring & Datalogging

Perimeter Security System

APN1001: Circuit Models for Plastic Packaged Microwave Diodes

Hardware & Software Solutions

ESP 20/20. Compressor Monitoring System

Autos Limited Ghana Vehicle Tracking Business Proposal

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

S100. GSM House Alarm System.

HDCATS-100. Installation Guide

EQUIPMENT SPECIFICATIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

3500/62 Process Variable Monitor

Nest Learning Thermostat Installation Guide. Installation step-by-step

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Service Description: Cisco Prime Home Hosted Services. This document describes the Cisco Prime Home Hosted Services.

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ALL WEATHER, INC. SOFTWARE END USER LICENSE AGREEMENT

ATC-300 Automatic Transfer Switch Controller

The software is sold on an AS IS basis. ALVARION, its affiliates or its licensors MAKE NO

GSM ATT Modules Simply effective remote control

40.3. Control Relays and Timers

User Manual. Humidity-Temperature Chart Recorder. Model RH520

SKY LF: 20 MHz-3.0 GHz High Power SP4T Switch With Decoder

Transcription:

SAGEON SITE MONITOR (SSM) Application Note AN103-4012-00 AN 103-4012-00, Issue 2a sageon_sm-an.pdf www.unipowerco.com SALES: +1-800-440-3504 HEAD OFFICE: +1-954-346-2442 EUROPE: +44 (0)1903 768200

SAGEON SITE MONITOR (SSM) Application Note - 2 ISSUE HISTORY Issue Page(s) Description Date Altered 1 All Initial Release MF 8/05/2004 2 All Transfer to UNIPOWER template NF 2/25/2015 2a All New Branding NF 4/11/2016 CONTACTS UNIPOWER LLC 18 Industrial Park Road Dunlap, TN 38327 Applications Engineering Voice: (800) 440-3504 Customer Service Voice: (800) 440-3504 Fax: (423) 949-3647 Field Service Voice: (800) 873-2707 Sales Voice: (800) 543-8630 Fax: (215) 619-7814 Web site URL: http://www.unipowerco.com PROPRIETARY AND CONFIDENTIAL The information contained in this document is the sole property of UNIPOWER LLC Reproduction of this document or any portion of this document without the written permission of UNIPOWER LLC is prohibited. DISCLAIMER Data, descriptions, and specifications presented herein are subject to revision by UNIPOWER LLC without notice. While such information is believed to be accurate as indicated herein, UNIPOWER LLC makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, UNIPOWER LLC hereby disclaims and excludes all warranties, express, implied, or statutory, including any warranty of merchantability, any warranty of fitness for a particular purpose, and any implied warranties otherwise arising from course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user s intended purpose and in user s specific application. Copyright UNIPOWER LLC 2004-2015 Sageon and SageView are trademarks of UNIPOWER LLC Other trademarks are the property of their respective owners.

SAGEON SITE MONITOR (SSM) Application Note - 3 1. Introduction The Sageon Site Monitor (SSM) is an auxiliary module for the Sageon DC Power Plant. The SSM provides additional I/O for the power plant enabling users to monitor the status of additional equipment through the Sageon system. The SSM includes twelve digital inputs and eight analog inputs for monitoring devices such as site security (door and window magnetic switches), AC Inverter status and alarms, Generator status (fuel level, oil pressure), and HVAC status and alarms. Also included are four voltage free (dry), Form C control output relays. The control relays can be automatically activated in response to an event on any of the SSM digital or analog input (configurable by the user), or operated manually from a PC running SageView. 2. Applications The SSM provides a simple, integrated solution to many common application challenges eliminating the need to purchase separate monitoring equipment. Using the remote communication capabilities and SageView software, the Sageon system can be remotely monitored, allowing the appropriate response to site events. Typical applications include: Integration of site alarms Integration of Inverter status Individual load monitoring Integration of auxiliary equipment status 3. Example Installation In this example the auxiliary site equipment is integrated into the site monitor. The I/O for this application include: Analog Inputs Generator fuel level Generator output voltage, current, and frequency Inverter output voltage, current, and frequency Digital Inputs Window and door opening sensors HVAC alarms Digital Outputs NOC alarm generation Local alarms Strobe lights

SAGEON SITE MONITOR (SSM) Application Note - 4 POWER PLANT 4 C/O RELAY CONTACT OUTPUTS Expansion module cable to SCU HVAC f I 12 DIGITAL INPUTS V SSM INVERTERS V I f FUEL 8 ANALOG INPUTS GENERATOR DIESEL FUEL LEVEL 4. System Configuration The SSM is easily configured using the SageView program included with each Sageon DC Power Plant. The Site Monitor configuration screen is pictured below and provides a simple, intuitive user interface. User Supplied Descriptive Tags Scaling and units of measure Fully Assignable Outputs Output Test Compatible with normally open or closed (failsafe) inputs

SAGEON SITE MONITOR (SSM) Application Note - 5 Each input has a user-defined label field (up to 8 characters) to describe its function. If a label field is left blank, the corresponding input is treated as not used. Analog input fields also include a two-character field for the description of the units of measure as well as high and low alarm thresholds. Scaling factor for analog inputs are set-up for 0 volts (0% F.S.) to 4 volts (100% F.S.). The type of digital input source (normally open or normally closed) is user definable by selecting the appropriate check box. Each discrete output can be automatically generated based on any combination of discrete and analog inputs. 5. Electrical Specification Analog inputs Number of inputs: 8 Input Range: 0 to +4Vdc Full Scale, Over-voltage and reverse polarity protected. Configuration: Scaling factor, low and high alarm levels are user programmable. Electrical Isolation: Non-isolated. Each analog input source must be isolated. Digital inputs Number of inputs: 12 Source type: Voltage free (dry) contact closure Active state: User defined (active open or active closed) Electrical Isolation: Non-isolated. Each digital input source must be isolated. Digital outputs Number of outputs: 4 Output type: Voltage free (dry) 1 Form C relay contacts Output rating: 1A@30VDC General Power Source: Plant Connection: Maximum Distance: Self powered from the Sageon Interface Board 16 conductor cable to the Sageon Interface Board 30 feet (9.14 meters) 6. Physical Specification Module Dimensions: 5.11 x 9.37 x 3.14 (130 x 238 x 80) (DxWxH) 2016 UNIPOWER LLC This document is believed to be correct at time of publication and Unipower LLC accepts no responsibility for consequences from printing errors or inaccuracies. All specifications subject to change without notice. sageon_sm-an-revc-0416.indd