9452/9453 Installation and User Guide



Similar documents
9448 Installation and User Guide

500r+ Installation and User Guide

TS510 & TS500. Installation & User Guide. Compatible Equipment

ACTIVE 5 ENGINEERING MANUAL

CONTENTS 4. HOW TO UNSET THE PANEL...7

How To Set A Timer On A Gg System

Accenta/Optima. Engineer s Manual. Honeywell Security. 8SP399A - Accenta mini panel with remote LCD keypad and communicator outputs.

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Intruder alarm system Engineering Information

Using your LED Plus keypad

User Guide Veritas 8/Veritas 8Compact/Veritas R8 INS036-5

HARDWIRED CONTROL PANELS

ACP10 10 Zone Intruder Alarm System

User.QXD 09/05/00 14:47 Page 1 Gardtec /582 User Instructions

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panels. Issue 12

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

astec Integrated Alarm System USER GUIDE

Intruder alarm system Operating Instructions

TS590. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT 0 ESC

Control/Communicator Installation Manual

SECURIT 800L+ CONTROL PANEL

User s Information Guide R1A

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

Security System User Guide

Intruder alarm system Engineering Information

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

USER GUIDE HARDWIRED CONTROL UNIT

IMPORTANT USER INFORMATION

Speech Dialler Engineering Information

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

IDS X-Series User Manual D Issued July 2012

Digital Keypad Use s Manual

Master User Guide Premier Elite 24/48/88/168/640

INSTALLATION MANUAL CONTENTS

AC-115 Compact Networked Single Door Controller. Installation and User Manual

NetworX NX-6V2. LED Keypad User Manual

How To Control A Car Alarm On A Car With A Remote Control System

SECURIT 800L+ CONTROL PANEL

NESS D Zone Control Panel and Dialler OWNER S MANUAL

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

INSTALLATION AND PROGRAMMING GUIDE HARDWIRED CONTROL PANEL

ICP-CC488. Installation Guide ICP-CC488 Control Panel

Installation Manual for D1110 DigiCom2

SECURITY SYSTEM NOTES

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Users Guide to Keypad Functions

SECURITY SYSTEM NOTES

MATRIX 6/816. Control Panel with Remote Keypads Software Version 1.34 USER MANUAL RINS545-7

9x5x PROGRAMMING GUIDE

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

Solution 862 Operators Manual. Issue 1.00

Solution-16 Operators Manual ISSUE 1.60

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

INSTALLATION GUIDE. FCC ID NOTICE

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

i 70 Installation Manual V1.04 Contents Grade 2 Wireless Intruder Alarm System YOUR SECURITY IS OUR PRIORITY Installation Instructions 2

NetworX Series. NX-148E LCD Keypad. User Manual

PA4. 4 Zone Wired Intruder Alarm System. Installation & Operating Manual. MAINS CLEAR 24Hr. Zone 1 Zone 2 Zone 3 Zone 4

THANK YOU FOR VOTING TEXECOM MASTER USER MANUAL. Security Control Panels with Integrated Communicator. Issue 6

Master User Guide Premier Elite Series

EURO User Manual. Castle Care-Tech 2012 (RINS1531) Issue 2. Page 1

INSTALLATION MANUAL PC2525. Version 1.1

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Speech Dialler Engineering Information

Automatic Telephone Dialer TD-101(W)

User Guide Premier Elite 24/48/88/168/640

Destiny Destiny Owners Manual

SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration

Programming & Installation PIEZO WARNING. EN : 2009 EN : 2008 EN : 2005 Security Grade 2 Environmental Class II RINS1347-2

!"#$%&"'()**+),-+)).( /'0%1##1%&"'(21'$1#( ISSUE 1.40

SECURITY SYSTEM NOTES. Security System Configuration

Galaxy 2 Series. User Guide. Honeywell Security

Security System Installation and Programming Guide

tattletale User Guide Consumer unit version P a g e

UNSET TAMPER FINAL EXIT

Diamond + User Manual. Wireless Alarm System. Default codes: User code: 1234 Master Manager Code: 2222

Solution 880 Operators Manual ISSUE 1.10

WIRELESS HOME ALARM SYSTEM (WHA1)

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

SECTION DETECTION AND ALARM

HILLS Series LED Code Pad User Manual

AUTODIALLER / QUICKDIALLER - SA132

System Introduction S E C T I O N 1

HomeSafe Security Panel User s Guide 5400 Series

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS

ICP-CP500. User's Guide ICP-CP500 Codepads

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY. SIERRA Page 1

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

1R / 4-BUTTON SERIES

Secure Keypads for access control

616, 626, 636 & 646 Keypads

VEHICLE SECURITY SYSTEM G25/G20

DESTINY OWNER S MANUAL

HILLS Series LED Code Pad User Manual

Transcription:

9452/9453 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4-Channel Minicom 496330 Issue 1 1 of 10

9452/3 Introduction The 9452 and 9453 are fully programmable 4 zone control units designed to meet the requirements of both domestic and small commercial installations. The basic 9452 system comprises a main control panel complete with built-in keypad, while the 9453 system comprises a blank end station and one remote keypad. The 9452 control unit and 9453 end station both house the system electronics, power supply, battery and remote signalling device (if fitted). A numeric keypad and row of indicators (LEDs) are provided only on the 9452 control unit, from which the user and installer perform the system operation. Remote keypads provide the user with the facility to set and unset the system from strategic locations within the premises and allow the installer to programme the system. Up to TWO remote keypads may be connected to the 9452/3. A numeric keypad and row of indicators (LEDs) are also provided on the keypads to perform the system operation. The keypads also have an optional key press PA facility, if required. Zones Display Keypads Technical Specification Four plus PA, Entry/Exit and global tamper. LED. One built-in (9452 only) plus up to two remote keypads (9425). None. Full Spec. 15 events. Yes. 9040, 2 max if Internal Speaker is disconnected. 1.9Ah. Expansion BS 4737 Log Panel Siren Extension Spkr Battery 12 Volt Power Quiescent Panel 70mA. 9425 RKP = 40mA. 12 V Aux Output 350mA. Dimensions Weight Comms Output Input Outputs Panel: h x w x d 163 x 257 x 72mm. RKP: h x w x d 115 x 115 x 28mm. Panel 1.2Kg. PA, Intruder, Open/Close. Line fault. SAB/SCB, Strobe, Prog O/P (PIR set latch or SD reset). 2 of 10 496330 Issue 1

9452/3 Wiring Communicator Output Pins Figure 1. 9452/3 PCB Layout Pin on panel Function Colour Pin on communicator Pin 1 PA Red ST2 Pin2 Line Monitor Input Blue O/P Pin 3 Intruder Yellow ST3 Pin 4 Open/Close Black ST4 Pin 5 +12V Brown 12V Pin 6 0V Orange 0V Notes: 1. Pins 1, 3 and 4 are removal of positive in alarm to trigger. 2. Pin 2 is a 12V +ve input for Line Fault. 3. If a communicator is fitted and has an output for line fault, connecting a +ve to the Line Monitor Input will reduce any programmed bell delay to zero and give a visual indication on the panel LED (LF). 4. If a communicator is not fitted remove the communicator wiring harness from the main pcb. 496330 Issue 1 3 of 10

Programming 9452/3 Keypad Wiring Figure 2. Keypad Connection. Notes: 1. Maximum cable distance: Daisy chain = 300m, Star Wire = 100m per leg. 2. Do not wire the extension speaker or circuit wiring within the same cable as the remote keypad. Initial Start Up Programming Before applying power to the control panel or end station, ensure that all used circuits are connected. The control panel or end station lid switch should be defeated or closed and NO power connections to detectors, sounders or battery should be made at this stage. Note: If connections to the bell and AUX power are made when the system is powered up, damage to the main pcb may occur. 1. Apply mains to the control panel or end station. The green Power and Day LED will illuminate and the internal sounder will sound. 2. Key-in the factory default customer code 1234. The internal sounder will stop and the Tamper, Service and Fault LEDs will be flashing. 4 of 10 496330 Issue 1

9452/3 Programming Commands 3. Key-in the factory default engineer code, 0 followed by ENTER then 7890. The Fault and Service LEDs will flash and the internal sounder will be bleeping. 4. Open the control panel or end station lid. The internal sounder stops bleeping and the Service LED will be steady. Make connections to AUX power, stand-by battery and connections to SAB. Proceed to program the system. Note: If an SAB/SCB module is fitted within the bell, it will continue to ring until the panel supply is connected and until the bell cover lid tamper switch is closed. Programming Commands To change the factory default program, use the commands listed in this section as follows: 1. Enter the command number. 2. Enter one or more digits to give the new program. 3. Press ENTER. The panel will give a double bleep to show that it has accepted the command. If you enter the command incorrectly the panel gives a single tone. Default Settings When delivered from the factory, the panel is programmed as follows: Zone 1, Entry Route Part Set zone. 01 36 Zone 2, Normal alarm, active in Part Set, Omit allowed. 02 16 OMIT Zone 3, Normal Alarm, active in Part Set, Omit allowed. 03 16 OMIT Zone 4, Normal Alarm, active in Part Set, Omit allowed. 04 16 OMIT Zone 7(E/E) part set. 07 6 User code 1234 Engineering Program Commands To change Key in: Followed by + ENTER Zones 1-4 01-04 0 = Not used 1 = Normal Alarm 2 = 24 Hour Alarm 3 = Entry Route 4 = Double Knock 5 = Chime 6 = Part set zone OMIT = Omit Allowed 496330 Issue 1 5 of 10

Engineering Program Commands 9452/3 To change Key in: Followed by + ENTER Default Entry/exit zone options 07 0 = Reset to none 5 = Chime 6 = Part set zone Programmable Output 11 18 = PIR set latch y 29 = Shock sensor reset Engineer Access 20 Any 4 digit code 7890 Bell output type 21 0 = SAB y 1 = SCB Internal sounder 22 1 = Follows strobe y 0 = Follows bell PA 30 0 = Audible Alarm y 1 = Silent Alarm System Reset 31 0 = Customer Reset y 1 = Engineer Reset Abort facility 32 0 = Disabled y 1 = Enabled Keypad PA 33 0 = Disabled y 1 = Enabled System status 34 0 = LEDs ON when set and part set 1 = LEDs OFF when set and part set. y Exit Mode 35 0 = Timed or Terminated y 1 = Final Door Set Rearm 40 0 = Never y 1 = Once 2 = Twice 3 = Three times 4 = Always External sounder delay 41 0 = Nil y 1 = 1.5 mins 2 = 3 mins 3 = 5 mins 4 = 10 mins 5 = 15 mins 6 = 20 mins 7 = No duration Ext. sounder duration 42 0 = Nil 1 = 1.5 mins 2 = 3 mins y 3 = 5 mins 4 = 10 mins 5 = 15 mins 6 = 20 mins 7 = No duration 6 of 10 496330 Issue 1

9452/3 Refresh NVM (System Memory Chip) To change Key in: Followed by + ENTER Default Entry Time 43 0 = Continuous 1 = 10s 2 = 20s y 3 = 30s 4 = 60s 5 = 90s 6 = 120s Exit Time 44 0 = Continuous 1 = 10s y 2 = 20s 3 = 30s 4 = 60s 5 = 90s 6 = 120s CSID code 50 nnnn (key in four digit code) Part Set Entry/Exit 60 0 = As Final Exit y 1 = Normal Alarm Part Set Entry Response 61 0 = As Entry Route 1 = Start Entry Timer y Part Set Exit Mode 62 0 = As Full Set 1 = 10 Second Set y 2 = Instant Set Part Set Alarm Response 63 0 = Local (No comms) y 1 = Full Alarm Engineer Log 90 1 see earlier events. 3 to see more recent events. ENTER to quit log. (15 events max.) External Sounder 91 ENTER to stop test. Strobe 92 ENTER to stop test. Internal Sounder 93 ENTER to stop test. Test keypad LEDs 94 ENTER to stop test Output 1 95 ENTER to stop test. Walk Test 97 ENTER to stop test. Load Factory Defaults 98 Leave Engineering Mode 99 Refresh NVM (System Memory Chip) The 9452/3 control panels have a Non Volatile Memory chip which retains all programmed information and access codes. If the system suffers a total power failure, the NVM will retain all information and the panel will only require powering up and resetting. However, if the end user forgets the user access code or the installer wants to return the panel to the factory programmed settings, continue as follows: 496330 Issue 1 7 of 10

Fault Finding 9452/3 1. Power down the control panel, mains and battery. 2. Find the RST pins, located to the middle of the control pcb. 3. Place a small screwdriver blade to short between the RST pins. With the blade still across the pins, power up the control panel battery first, then Mains. All the LEDs will flash. 4. Remove the screwdriver blade. The control panel loads the factory default codes. 5. Key-in 1234, then press 0 Enter 7890. Momentarily close, then open up control panel lid. Re-program the system. Engineer Reset An engineer can reset the system without opening the control panel or end station lid. 1. Press 0 then Enter. 2. Key in the Engineer Access Code. 3. Key in 99. To Re-Enter Programming Mode 1. Press 0 then Enter. 2. Key in the Engineer Access Code. The Fault and Service LEDs flash and the internal sounder starts bleeping. 3. Open the control panel or end station lid. The internal sounder stops bleeping and the Service LED glows steadily. The system is now in programming mode. To Leave Programming Mode 1. Close the panel or end station lid. 2. Key in 99. Fault Finding Under normal conditions, the Fault, Service and Alarm LEDs will not be illuminated. Only the Mains, Day Full and Part Set LEDs should be illuminated during normal use of the system. Any other LEDs which are illuminated or flashing, signify a fault or alarm condition. Note: The Mains LED will be illuminated permanently. Any condition indicated by a combination of the Fault, Service or Alarm LEDs are to be considered an abnormal condition, as shown on the opposite page: 8 of 10 496330 Issue 1

9452/3 Fault Finding 496330 Issue 1 9 of 10

9452/3 Full Set System Part Set System Unset/Reset System Omit zone User Commands 1 + ENTER + User code 2 + ENTER + User code User code 1 (or 2) + ENTER + User code + OMIT + zone number (repeat OMIT + zone number for other zones as required). Omit 24 hr zone OMIT + ENTER + User code + zone number (+ zone number for other zones as required) Change User code 4 + ENTER + Old code + Old code (the system beeps twice)+ New code (the system beeps twice) Read Log 5 + ENTER + User code 1 to read earlier events 3 to read later events ENTER to leave the log Chime On/Off 7 + ENTER + User code Bell Test 8 + ENTER + User code Walk Test 9 + ENTER + User code ENTER to end the test 10 of 10 496330 Issue 1