Operating instructions Supply system for flammable liquids. Labor



Similar documents
Installation and safety instructions for AC/DC built-in devices

GUIDELINES - Gas Inspection Regulations 1. Recommendations for camping site owners

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Hydraulic control unit series

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Structured Cabling, Earthing & Equipotential Bonding

804 Ti Stand. Manual EN

Leak Detection System

Building Services Engineering Technician

TMS TANK MANAGEMENT SYSTEM

Operation Manual. Diaphragm pumps 1-headed MPC 301 E

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

HERZ-Thermal Actuators

Elektromotoren und Gerätebau Barleben GmbH

Fire Safety Regulations Part B according to DIN 14096

SunMaxx Solar Filling Station Operating Instructions

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Operating Instructions Drill rig DRU160

Hot Water Urns. all models. Helpline. v3.0

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

5162 E. Working in oxygen-reduced atmospheres BGI/GUV-I 5162 E. Information

Operating Instructions

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

3053 Electrical Safety Training Program Course Outline

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Emergency safety showers Part 3: Body showers for production and logistic sites

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Instructions for Safe Use

FLEXIT S4 R S6 R S7 R

Elektromotoren und Gerätebau Barleben GmbH

National- Spencer Inc.

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Firewall. Propane flame projector Safety instructions and operating manual

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

ŠkodaOctavia Supplement - for vehicles with LPG drive

aseries A13B Mini Bullet Camera User Manual

Manual v1 Page 1 of 17. Manual. Laboratory autoclave

LABORATORY SAFETY INSPECTION CHECKLIST

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Operating Instructions

CO2 Alarm. Operation. Application

Safety information. MSX-Box. ADDI-DATA GmbH Airpark Business Center Airport Boulevard B Rheinmünster Germany

Operating Instructions

CG PTFE Diaphragm Liquid Transfer Pump

PEROXIDE SAFETY DATA SHEET (60% H2O2) Safety Data Sheet

This leaflet provides information on

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Take care with oxygen Fire and explosion hazards in the use of oxygen

Operating instructions

Getting the best from your urn

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Instruction Manual Differential Pressure Transmitter

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Emergency Response Guide

Server Rack Commissioning

MIC-WKT and MIC-WKT-IR

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

WATER BATH. Art. No /115/1400 (115 V) 35097/230/1400 (230 V) OPERATING INSTRUCTIONS. User information: Water bath Teflon mesh

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

Safety and Environmental Information for External Companies

PBX Series Quick Fit Connector Bimetallic Steam Traps

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

LC/LCD ranges level controllers

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l

FF30. Flexicon. Operator s Manual. FF30-F In-feed Rotary Table. OPERATOR S MANUAL Serial Number yyww xxxx. Filling and Capping System

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

VACUUM CLEANER INSTRUCTION MANUAL

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

BRO Roles & Responsibilities Form Page 1 of 9

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

TIG INVERTER INSTRUCTION MANUAL

Operating instructions

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Safety and Environmental Information for External Companies Koehler Oberkirch

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Pressure Vessels (Air Compressors) and LPG Tanks

Maintenance and Operating Instructions SIS 120P/SISF

How To Use A Flowmeter

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Code of Practice for the Manual Handling of Gas Cylinder and exchange of regulators

OSHA Office of Training and Education 1

SEMME3012 Installing marine lighting, alarm, detection and monitoring equipment and systems

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Operating Instructions

Topvex SX/C, Topvex TX/C. Air Handling Unit

DIGITAL PARAFFIN DISPENSER MODEL DP 2010 PROCEEDING MANUAL

Conventional Fire Detection and Extinguishant Control System Specification

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

PROMG4 Install mining backup services

Transcription:

Operating instructions Supply system for flammable liquids Labor

Table of contents Safety General safety instructions.................... 2 Warning instructions used in this operating instruction 3 Correct use................................ 3 Work performed by WALDNER................ 4 Compliance with standards.................... 4 Description Designs.................................. 5 Cyclic supply.............................. 6 Continuous supply.......................... 7 Operation Specific safety instructions.................... 9 Changing the containers......................10 Help Malfunctions during general operation...........11 Technical data Technical data for the supply system............12 Standards and technical rules Quality, health and safety.....................13 Laboratory furniture.........................13 Fittings and pipe systems.....................14 Electrical engineering and electronics............14 1

Safety Safety General safety instructions It is imperative that the following safety instructions are observed when using WALDNER laboratory furniture: If you smell gas, immediately open all windows and do not operate any electrical control elements (e. g. light switches). In case of fire, inform the Fire Brigade without delay and fight the fire with a fire extinguisher until the Fire Brigade arrives. Always keep the access to emergency showers, eye showers and emergency exits clear. Always wear appropriate safety clothing in laboratories. In case of an accident with electrical power, immediately operate the emergency stop button. Only perform hazardous tasks on your own when another person can provide first-aid in an emergency. Only use items of equipment that have been tested and that are in correct working order. Have any defects rectified without delay and inform your supervisor. Only leave the workplace if continuous supervision of your work is not necessary or if another person takes over supervision. Only work outside normal working hours with suitable precautionary measures and if it is not possible to perform the work at another time. Store hazardous materials so that they do not create a hazard to health or the environment. In general observe the following directives, specification and regulations: Richtlinien für Laboratorien der Berufsgenossenschaften (Guidelines for Laboratories) (BGR 120) Health and safety regulations Allgemeine Vorschriften (Annex 1 of the Accident Prevention Regulations "General Rules") (BGV A1) Gesundheitsdienst (Health service) (BGV C8) Umgang mit krebserregenden Gefahrstoffen (Handling carcinogenic hazardous materials) (VBG 113) Gefahrstoffverordnung (Hazardous Materials Regulations) Arbeitsstättenverordnung (Workplaces Ordinance) Legal regulations on waste 2

Safety Warning instructions used in this operating instruction In this section warnings about hazards are provided in the form of warning instructions. The nature of the hazard and the hazard category are identified by a symbol and a signal word. It is imperative that the information on how to avoid the hazard is observed. The following hazard categories are used in this document as required. DANGER! identifies hazards to the health. WARNING! is used with all warning instructions that could result in minor injuries or damage if they are not observed. CAUTION! is used with all warning instructions that could result in damage if they are not observed. SIGNAL WORD Nature and source of the hazard Possible consequence of failure to observe Information on how to avoid the hazard Correct use The supply system enables flammable liquids to be safely stored and made available in the laboratory environment. To prevent damage to the supply system, compatibility with the materials in the supply system must be ensured. When handling flammable liquids, the information in the related instruction sheet in accordance with 20 Gefahr- Stoff-Verordnung (GefStoffV) (Hazardous Materials Regulations) is to be observed. 3

Safety Work performed by WALDNER Installation and modification of WALDNER laboratory furniture is only allowed to be performed by WALDNER service personnel or authorised personnel. Maintenance on WALDNER laboratory furniture are only allowed to be performed by appropriately qualified personnel or WALDNER service personnel. Maintenance work must be performed regularly every 12 months. The spare parts required must be recorded in a log. Compliance with standards During the planning, manufacture and the installation of the WALDNER laboratory furniture product range, the applicable specifications such as EN standards, DIN, DVGW, GS marking, CE marking, VDE, BGV and VDI regulations and other official specifications and conditions in the Standards and technical rules section are taken into account. 4

Description Designs Description A special security cabinet is used for the supply system for flammable liquids. The security cabinet is connected to an ectract system and an earth wire with equipotential bonding. The security cabinet contains suitable containers for storing and providing flammable liquids. The containers are pressurised to a defined pressure using a pressure regulator. This enables the flammable liquid to be pumped out of the container. The following types of supply are possible: Cyclic supply with different flammable liquids Continuous supply with automatic changeover to second container 5

Description Cyclic supply In the case of cyclic supply, there are up to two containers with flammable liquids in the security cabinet. The containers are connected to the outlets using separate pipes. Cyclic supply Security cabinet Pressure regulator Outlet pipe Inert gas pipe Container As long as there is flammable liquid in the container, the liquid can be drawn using the outlet pipe. When it is not possible to draw any more liquid, the container must be changed, see page 10. 6

Description Continuous supply In the case of continuous supply, there are two containers with the same flammable liquid in the security cabinet. The containers are connected to a monitoring system and connect to the outlet nozzle using a common pipe. Continuous supply Security cabinet Pressure regulator Outlet pipe Inert gas pipe Electrical module for the monitoring system Container The monitoring system detects when a container is empty and automatically switches to the second container. 7

Description Monitoring system The two containers are each connected to the pipe to the outlet using a diaphragm valve. One diaphragm valve is always open when liquid is drawn. A sensor monitors whether liquid is still drawn. As soon as a container is empty, the monitoring system switches to the second container. A lamp on the electrical module is used to visually indicate when a container is empty. Monitoring system for continuous supply Switch button for lamp, second container Indicator for second diaphragm valve Indicator for first diaphragm valve Switch button for lamp, first container Green operation indicator Switch button for monitoring system The monitoring system has the following control elements: Control element Indication/function Lamps The related container must be changed, see page 10. Switch buttons for lamps Deactivate the lamps. Indicators for diaphragm valves 8 The related diaphragm valve is open. Green operation indicator The monitoring system is ready for use. Switch button for monitoring system Switch on/switch off the monitoring system

Operation Operation Specific safety instructions It is imperative that the following safety instructions are observed when using the supply system for flammable liquids: Observe Verordnung für brennbare Flüssigkeiten (VbF) (Regulations on flammable liquids). Note date of manufacture on the containers. Always connect containers to earth wire. Only store containers with flammable liquids in the security cabinet. Note safety data sheets for the flammable liquids. Note monitoring unit. Close the gas supply if it is not going to be used for a longer period (e.g. overnight). Screw thread adapter to the containers hand-tight. Keep supply air and extract air paths clear in the security cabinet. Only open electrical modules if the entire power supply has been de-energized. CAUTION! Extremely aggressive flammable liquids Damage to the supply system Prior to drawing flammable liquids, check compatibility with the materials of the supply system. DANGER! Sparking Explosion and burns 1. Connect containers to earth wires. 2. Do not wear clothes or shoes made of plastic. 9

Operation Changing the containers When a container is empty, the container must be removed and a full container connected. DANGER! Sparking Explosion and burns 1. Ensure that sparking is not possible. 2. Do not wear clothes or shoes made of plastic. Removing empty container: 1. Open security cabinet. 2. Close the gas supply at the pressure reducer. 3. Actuate the pistol-grip nozzle in the cabinet to carry out pressure relief. 4. Remove the helical gas supply hose from the container. 5. Remove the metal hose to the outlet pipe from the container. 6. Remove empty container. 7. Fit threaded adapter with tube. 8. Remove earth wire on the container. 9. Close the empty container by hand using the original cover. A full container can now be connected. Connecting full container: 1. Connect earth wire to the full container. 2. Put full container in place. 3. Unscrew the original cover. 4. Fit threaded adapter and tighten by hand. 5. Connect the metal hose to the outlet pipe to the container. 6. Connect the helical gas supply hose to the container. 7. Open the gas supply at the pressure reducer. 8. Close security cabinet. 10

Help Help Malfunctions during general operation Malfunction Possible cause Repair Green operation indicator does not illuminate. Monitoring system does not work. It is not possible to draw liquid. No power supply Lamp is faulty Broken cable Switch faulty 1. Check power supply and fuse. 2. Call customer service. 1. Check threaded adapter on the container, see page 10. 2. Inform customer service. No gas pressure Check gas pressure. 11

Technical data Technical data Technical data for the supply system Security cabinet Width 595 mm Depth 600 mm Height 2170 mm Height, plinth 80 mm Number of containers 2x30 litres Complies with DIN 12925 part 1 and TRbF 22 Container Diameter 370 mm Height 440 mm Material Stainless steel 12

Standards and technical rules Standards and technical rules Quality, health and safety Standard DIN ISO 9001: 2000 BGR 120 Directive 94/9/EC TRGS 526 TRBA 100 BetrSichV Content Quality assurance standard Berufsgenossenschaftliche Regeln für Sicherheit und Gesundheitsschutz für Laboratorien/Richtlinien für Laboratorien (formerly ZH 1/119) (Guidelines for Laboratories) Equipment and protective systems intended for use in potentially explosive atmospheres Technische Regeln für gefährliche Stoffe (Technical Rules for Hazardous Substances) Schutzmaßnahmen für gezielte und nicht gezielte Tätigkeiten mit biologischen Arbeitsstoffen in Laboratorien (Protective measures for specific and unspecific work in laboratories involving biological agents) Betriebssicherheitsverordnung über Arbeitsmittel, überwachungsbedürftiger Anlagen und des Arbeitsschutzes (Ordinance on safety and health protection during the provision and use of working tools, safety during the operation of facilities requiring surveillance, and the organization of occupational safety and health), issue Sept. 2002 Laboratory furniture Standard DIN 12000 pren 14056 DIN 12925, Part 2 DIN EN 14470, Part 1 pren 14470, Part 2 DIN 1946, part 7 Content Graphic symbols and safety marking in laboratories Laboratory furniture. Recommendations for design and installation Laboratory furniture; cupboards for pressure cylinders; safety requirements, testing Fire safety storage cabinets: Safety storage cabinets for flammable liquids Feuerwiderstandsfähige Lagerschränke: Sicherheitsschränke für Druckgasflaschen (Fire safety storage cabinets - Safety storage cabinets for pressurised gas cylinders.) Heating, ventilation and air conditioning; HVAC systems in laboratories 13

Standards and technical rules Fittings and pipe systems Standard TRG 280 TRbF 20 Content Technische Regeln Druckgase - Allgemeine Anforderungen an Druckgasbehälter - Betreiben von Druckgasbehältern (General requirements on compressed gas tanks - Operation of compressed gas tanks) Technische Regeln für brennbare Flüssigkeiten, (Technical Rules on Flammable Liquids - Storage) issue April 2001 Electrical engineering and electronics Standard DIN EN 61010, part 1 VDE 0411, Part 1 DIN VDE 0789, Part 100 DIN VDE 0100, Part 610 DIN VDE 1000 DIN VDE 0100 DIN VDE 0100, part 520 DIN VDE 0100, part 540 DIN EN VDE 61000-6-2 0839, Part 6-2 DIN EN VDE 61000-6-4 0839, Part 6-4 BGV A2 Content Safety requirements for electrical equipment for measurement, control and laboratory use Classrooms and laboratories fitments equipment and furniture safety specification for powered constructional units Erection of low-voltage installations: Verification - Initial General Principles for the Safety Design of Technical Products Erection of power installations with nominal voltages up to 1000 V Selection and erection of electrical equipment Earthing arrangements, protective conductors, equipotential bonding conductors Electromagnetic compatibility (EMC) - Generic standards - Immunity for industrial environments Electromagnetic compatibility (EMC). Generic standards. Emission standard for industrial environments UV - Elektrische Anlagen und Betriebsmittel (Electrical Systems and Equipment) 14

Labor

WALDNER Laboreinrichtungen GmbH & Co. KG Haidoech 1 88239 Wangen Germany Telefon +49 7522 986-480 Telefax +49 7522 986-418 labor@waldner-lab.com www.waldner-lab.com