QSE-CI-NWK-E Control Interface



Similar documents
QSE-CI-DMX Control Interface

HomeWorks QS Processor

OMX-RS232 Control Interface

Control Interfaces. GRAFIKR Systems a LUT-DMX

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

IP Link Device Interface Ethernet Communication Sheet

GEU Port Gigabit Switch

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

RadioRA 2 (QS) Lighting and Climate Control. g! 5.4 Fan Controller: g! RadioRA2 Inclusive Software v5.0.8 or newer

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

IntesisBox Modbus Server Fidelio IP

Electronic Control Devices The European Product Catalogue 2007

Lutron. integration protocol

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

IntesisBox Modbus Server SAMSUNG Air Conditioners

Cable Pinouts. SRP I/O Module

Setup guide. point to point wall plate extenders

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

IntesisBox KNX Modbus TCP master

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

PCS0100en Persy Control Services B.V. Netherlands

LBNP RS-232/485/422 serial device server. User manual

OZS Web server. For LPB/BSB plants

LIEBERT VNSA Installation Sheet

MechoNet TM Network Interface (MNI) Specification Submittal

Hardware Reference. Linux Device Server IGW/922 with DIL/NetPC ADNP/9200

Portable BACnet /IP to MS/TP Router

Bluetooth HC-06 with serial port module Easy guide

IntesisBox KNX Modbus RTU master

IntesisBox KNX - LON

KNX Panasonic Air Conditioners

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

EcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystemR Dimming Module

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

USB to RS-422/485 Serial Adapter

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

1-Port R422/485 Serial PCIe Card

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Moxa EtherDevice Switch

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

Bluetooth to Serial Adapter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

MDI/MDIX) FEP-32008T-3

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

TrueAlarm Fire Alarm Systems

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

Application/Connection Examples

Lighting Control Systems

8-Port PoE Network Switch

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

Perle 10/100 Ethernet Media Converters

Modbus Server SAMSUNG Air Conditioners

Switching Power Module

TX OPEN RS232/485 module

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Telebyte 209 Short Haul Modem

4000 Series Installer s Guide

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual

Connector and Cable Specifications

One Port Serial Server Users Manual Model ESP901, ESP901E

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

HomeWorks QS Wired Signature SeriesTM Keypads

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

EMBEDDED ACCESS CONTROL Hardware Installation Guide

1 Port RS232 Serial over IP Device Server

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

OZW V2.0. Web server. Synco TM, Synco TM living

Phase-Adaptive Power Module

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

MOXA EtherDevice Switch

DK40 Datasheet & Hardware manual Version 2

IntesisBox KNX LG Air Conditioning

Cabling Guide for Console and AUX Ports

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

Encore Controller to Router Connections

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

User Manual. EtherUSB

RS-232/422/485, Power over Ethernet

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

1. SAFETY INFORMATION

TX2123 RS485 TO ETHERNET ADAPTOR

IntesisBox KNX Mitsubishi Heavy Industries AC

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

Electronic Control Devices The European Product Catalogue 2007

DOORKING SYSTEMS 1830 SERIES NETWORK WORKSHOP LAN APPLICATIONS ACCESS CONTROL SOLUTIONS LOCAL AREA NETWORK (LAN) CONNECTION REV 04.

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Transcription:

QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices can control and/or monitor a QS system. Features Easily integrate with touchscreens, PCs, A / V systems, or other digital systems and devices. Control and monitor GRAFIK Eye QS, Sivoia QS, Energi Savr NodeTM, and other products on the wired QS link. Monitor lighting scenes, levels, shade positions and more. For a full list of commands see Integration Protocol document (P/N 040249) at www.lutron.com Up to 10 QSE-CI-NWK-E control interfaces are allowed per QS link. The QSE-CI-NWK-E is Quantum compatible. Refer to the Quantum System Specification Sheet (P/N 369634) at www.lutron.com for compatibility details.

Specifications Power SELV / PELV / NEC Class 2 Operating voltage: 24 36 V- 65 ma QS Link Limits The QS wired communications link is limited to 100 devices and 100 zones. Each QSE-CI-NWK-E control interface counts as 1 device and 0 zones. Each QSE-CI-NWK-E control interface consumes 2 Power Draw Units (PDU) on the QS link. Refer to the QS Link Power Draw Units Specification Submittal (P/N 369405) at www.lutron.com for more information. The maximum wiring length for the QS link is 2000 ft (610 m). Environment 32 F to 104 F (0 C to 40 C). Relative humidity less than 90% non-condensing. Indoor use only. Unit generates heat, maximum 8 BTU / hr. Integration Features Monitoring: Current scene, zone level, button presses, shade group levels. Control: Scene selection, scene lockout, zone lockout, sequencing, zone raise / lower, master raise / lower, set shade group level, simulate button press/release. For the full list of features and commands, please refer to the Integration Protocol document (P/N 040249) on the accompanying CD or at www.lutron.com Compatible Components Compatible with most QS devices. For a complete list of compatible components see Integration Protocol document (P/N 040249) at www.lutron.com Requirements QS Link Power Supply, such as a: GRAFIK Eye QS. QS Link power supply, such as the QSPS-P1-1-50. Energi Savr NodeTM QS. QS Communication Link - SELV / PELV / NEC Class 2 (see QS Link Wire Sizes table). 369373e 2 04.05.16 Protocol Integration Protocol document (P/N 040249) included on a CD accompanying the packaged QSE-CI-NWK-E. Also available for download, see Integration Protocol document (P/N 040249) at www.lutron.com RS232 Connection Standard 9-pin female serial connector on interface. 50 ft (15 m) maximum serial cable length. Dip switches are set at factory, all Off. Dip switches are used to set RS232 baud rate: DIP Switch Settings for RS232 Baud Rate 115200 (default) 38400 19200 9600 Ethernet Connection Standard CAT5 (or better) cable, 328 ft (100 m) maximum, connects the QSE-CI-NWK-E interface to a PC or other Ethernet source. Supports MDI / MDIX auto-crossover (no crossover cable needed). Auto-negotiation of 10 or 100 Mbps speed and full- or half-duplex operation. Default IP address is 192.168.250.1. Can be changed using the Lutron DeviceIP tool located on the accompanying CD. Note: Either the RS232 or the Ethernet can be used, but not both.

Dimensions 369373e 3 04.05.16 Dimensions are in inches (mm) 2.5 (63) Mounting holes Terminal blocks on this side LEDs and addressing switches on this side 3.75 (95) 4.25 (108) Mounting Hole Detail 0.1875 (5) dia. 0.3125 (9) dia. 1.0 (27) 5.25 (134) 0.25 (6) 0.1875 (5) dia. #6 or #8 (M3 or M4) screw recommended Mounting Options Mount where terminal blocks, switches, and LEDs are accessible. Strip 3/8 in (10 mm) of insulation from wires. Each data link terminal will accept up to two 18 AWG (1.0 mm 2 ) wires. Connect wiring as shown on the Wiring page. LED 1 lights continuously (Power) and LED 7 blinks rapidly (Data Link RX) when the SELV / PELV / NEC Class 2 Data Link is installed correctly. Choose from the following mounting methods: Mounting Methods 1 2 LUT-19AV-1U 1 Direct Wall Mounting Mount the control interface directly on a wall, as shown in Mounting Methods at right, using screws (not included). When mounting, provide sufficient space for connecting cables. Control Interface Wall 3 2 Rack Mounting Place the unit in the LUT-19AV-1U AV rack using screws provided with the unit. The LUT-19AV-1U will hold up to four units. LUT-5x10-ENC 3 Enclosed Wall Mounting If conduit is desired for wiring, use the LUT-5x10-ENC to mount one unit.

Terminal Locations 369373e 4 04.05.16 Ethernet Link (to PC or AV Equipment Female 9-pin RS232 Link (to PC or AV Equipment) QS Link to other wired QS system Devices LED and DIP Switch Locations 1 2 3 4 5 6 7 DIP Switches LED 1: Power LED 2: Ethernet Activity LED 3: Unused LED 4: RS232 Link Tx LED 5: RS232 Link Rx LED 6: QS Link Tx LED 7: QS Link Rx

Wiring RS232 Link Standard 9-pin serial connector plugs into RS232 equipment, and to QSE-CI-NWK-E. Must be 50 ft (15 m) or less. RS232 Signals Signals Com 5 TxD 3 RxD 2 Pin on 9-Pin Cable 369373e 5 04.05.16 Ethernet Link Wiring Standard CAT5 cable connects QSE-CI-NWK-E Interface to PC, router, or other Ethernet source. No crossover cable needed. Must be 328 ft (100 m) or less. Ethernet network and cable provided by others. Ethernet Link: CAT5 Cable: 328 ft (100 m) max. RS232 Cable 50 ft (15 m) max. COM TxD RxD QS Link 4321 RS232 Link To PC or AV Equipment Rear View of GRAFIK Eye QS Control Unit 1 2 A B C To additional QS devices QS Link: 1: Common 2: V+ 3: MUX 4: MUX See next page. Do not connect Pin 2 if using external power supply. 1 2 3 4 1 2 3 4 5 6 L N

Wiring (continued): QS Link Wiring Methods (choose one) 369373e 6 04.05.16 System communication uses SELV / PELV / NEC Class 2 wiring. Follow all local and national electrical codes for installation. Each terminal accepts up to two 18 AWG (1.0 mm²) wires or one 12 AWG (4.0 mm²) wire. Total length of control link must not exceed 2000 ft (610 m). Do not allow SELV / PELV / NEC Class 2 wires to contact live / mains wire. Typical Wire Sizes: See QS Link Wire Sizes table. Connect the terminal 1, 3, and 4 connections to all control units, wallstations, and control interfaces in the QS system. For terminal 2 connectivity, see below. Powered by GRAFIK Eye QS Control Unit Data Link: 4: MUX 3: MUX See QS Link Wire Sizes table 1 2 3 4 1 2 A B C Rear View of GRAFIK Eye QS Control Unit 1 2 3 4 5 6 L N 4321 QS Link Do not use external power supply if connecting Pin 2 SELV / PELV / NEC Class 2 Power wiring: 2: V+ 1: Common See QS Link Wire Sizes table To additional wallstations/ control interfaces Powered by a QS Link Power Supply* (1) twisted pair 22 AWG (0.5 mm 2 ) QS Link 1: Common 2: V+ 3: MUX 4: MUX QS Link 4321 PDU supplying device GRAFIK Eye QS Control Unit shown (1) 18 AWG (1.0 mm 2 ) Common QS Power Supply* To additional wallstations/ control interfaces Lutron Cable See QS Link Wire Sizes table Do not use external power supply if connecting Pin 2 * Note: For details regarding powering from the QS Link, please refer to the QS Power Draw Units Specification Submittal (P/N 369405) at www.lutron.com QS Link Wire Sizes (check compatibility in your area) QS Link Wiring Length Wire Gauge Lutron Cable Part Number Power (terminals 1 and 2) < 500 ft (153 m) 1 pair 18 AWG (1.0 mm 2 ) GRX-CBL-346S (non-plenum) Data (terminals 3 and 4) GRX-PCBL-346S (plenum) 1 twisted, shielded pair 22 AWG (0.5 mm 2 ) Power (terminals 1 and 2) GRX-CBL-46L 500 ft 2000 ft 1 pair 12 AWG (4.0 mm 2 ) (non-plenum) (153 m 610 m) Data (terminals 3 and 4) 1 twisted, shielded pair 22 AWG (0.5 mm 2 ) GRX-PCBL-46L (plenum)