HP Ethernet 10Gb 2-port 530SFP+ Adapter User Guide

Similar documents
HP NC523SFP 10Gb 2-port Ethernet Server Adapter User Guide

HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide

HP NC7170 Dual Port PCI-X 1000T Gigabit Server Adapter User Guide. June 2007 (Second Edition) Part Number B

HP POS Keyboard with MSR for Point of Sale System. User Guide

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

HP TFT7600 G2 Rackmount Keyboard Monitor KVM Console User Guide

HP STORAGEWORKS PCI TO FC HOST BUS ADAPTER

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

About the HotWire Slot Standalone Shelf

HP ProLiant Moonshot Cartridge User and Maintenance Guide

HP SATA/SAS hard drive and Solid State Drive installation

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

TG-3468 Gigabit PCI Express Network Adapter

HP TFT7600 Rackmount Keyboard and Monitor User Guide

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Technical Support. Support Information

4 Port PCI Express Gigabit Ethernet PoE PSE Network Card

MCR1900 Media Converter 19-Slot Chassis

HP USB Network Print Adapter. User Guide

Small form factor bay converter and hard drive installation

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

HP UPS R1500 Generation 3

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

IFS SP-PoE Splitter User Manual

PCI Express 10GBase-LR/SR/LRM Fiber Network Card with Open SFP Slot

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Regulatory Compliance Statement

AXIS 291 1U Video Server Rack Installation Guide

MoCA Adapter MC1001 v2 Installation Guide

PCI Express USB 2.0 Adapter Card

Gateway Port Replicator User Guide

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

TG-3468 Gigabit PCI Express Network Adapter

Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

HP 22-in-1 Media Card Reader

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

4 Port PCI Express Low Profile High Speed USB Card

USB 2.0 USB 2.0 ETHERNET AUDIO JACK AND RCA VIDEO HDMI MICRO SD CARD MICRO USB POWER

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

iosafe Solo External Hard Drive

Mini PCI Express FireWire Adapter Card

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

PCI Express USB 3.0 Controller Adapter Card

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

BroadBand PowerShield. User Manual

Cisco TelePresence MCU 4500 Series safety and compliance information

Power Over Ethernet Adapters POE101

PCI Express USB Card. PCI Express 4 Port USB 2.0 card PEX400USB2. Instruction Manual. Actual product may vary from photo

SanDisk Connect Wireless Flash Drive QUICK START GUIDE

Kvaser Mini PCI Express User s Guide

Zebra RW 420 Mobile Battery Eliminator Kits

BPM Series. Metered Rack Mount PDUs. Quick Start Guide. Models Covered:

ES-CAM3A Outdoor IP Camera

Hotwire 5620 RTU Installation Instructions. Contents. Hotwire 5620 RTU Overview. Document Number 5620-A2-GN11-40 September 2001

QuickSpecs. HP NC552SFP 10Gb 2-port Ethernet Server Adapter. HP NC552SFP 10Gb 2-port Ethernet Server Adapter. Overview

FortiFone QuickStart Guide for FON-670i and FON-675i

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

GSM-EXT Cable Assembly Installation Guide

Removable 2.5 SATA HDD Backup System

Stretch DisplayPort TM

PCI Express FireWire & USB 2.0 card

StorTrends 3400 Hardware Guide for Onsite Support

Power Supply Guide Version 1.0 for D-Show

ProLiant DL380 Generation 2 Server Maintenance and Service Guide

Upgrading and Servicing Guide

FortiFone QuickStart Guide for FON-370i

Perle Protocol Transparent Media Converter Modules

BladeRunner 4U Blade Server User Manual. December 2004 (Revision A)

IDE ATA/133 Controller

Triple Expansion Chassis

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Rocket Channel SATA 6Gb/s PCI-Express 2.0 x8 HBA

Memory Modules User Guide

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Compaq Presario Desktop Products. Upgrading and Servicing Guide

No. S8351. S8351 External Bluetooth module for mz series transmitter OPERATING INSTRUCTION

Broadband Telecommunications Drop Amplifier

USB Mini Print Server PS121. Installation Guide

EPSON USB/Parallel Adapter User s Guide

IMPORTANT SAFETY INSTRUCTIONS

Energy Smart Electric Water Heater Controller

IP DSLAM IDL Quick Installation Guide

DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide

HP UPS T1000/1500 User Guide

Wall-Mounting your HP computer. User Guide

USB 3.0 to M.2 NGFF SSD Enclosure with UASP

Hard Disk Drive (HDD)

ARCHOS (

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

User Guide Nokia Portable Wireless Charging Plate DC-50

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Transcription:

HP Ethernet 10Gb 2-port 530SFP+ Adapter User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels. Part Number: 679303-002 March 2012 Edition: 2

Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. Bluetooth is a trademark owned by its proprietor and used by Hewlett-Packard Company under license.

Contents Technician notes... 4 Warnings, cautions, and notes... 4 Downloading files... 4 HP contact information... 5 Introduction... 6 Overview... 6 LED indicators... 6 Installing an adapter... 7 Installation overview... 7 Preventing electrostatic discharge... 7 Installing an adapter in a server... 8 Installing a low profile bracket... 8 Connecting the network cable... 9 Specifications... 10 Cable specifications... 10 General specifications... 10 Compliance... 10 Power and environmental specifications... 11 Regulatory compliance notices... 12 Regulatory compliance identification numbers... 12 Federal Communications Commission Notice... 12 Modifications... 12 European Union regulatory notice... 12 Canadian notice (Avis Canadien)... 13 Korean class B notice... 13 Japanese class B notice... 13 Disposal of waste equipment by users in private households in the European Union... 13 Electrostatic discharge... 15 Preventing electrostatic discharge... 15 Grounding methods to prevent electrostatic discharge... 15 Acronyms and abbreviations... 16 Documentation feedback... 17 Contents 3

Technician notes Warnings, cautions, and notes WARNING: Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard. WARNING: To reduce the risk of electric shock, personal injury, and damage to the equipment: Do not attempt to service any parts of the equipment other than those specified in the following procedure. Any other activities may require that you shut down the server and remove the power cord. Installation and maintenance of this product must be performed by individuals who are knowledgeable about the procedures, precautions and hazards associated with the product. WARNING: To reduce the risk of electric shock or damage to the equipment: Do not disable the power cord grounding plug. The grounding plug is an important safety feature. Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times. Unplug the power cord from the power supply to disconnect power to the equipment. Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server. This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server. CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only. NOTE: Any indications of component replacement or printed wiring board modifications may void any warranty. Downloading files 1. Go to the HP website (http://www.hp.com/#support). Technician notes 4

2. Select Download drivers and software (and firmware). 3. Type the adapter name in the For product box and then click Go. For example, type HP Ethernet 10Gb 2-port 530SFP+. 4. Download the drivers, firmware, or documentation as needed. HP contact information For United States and worldwide contact information, see the Contact HP website (http://www.hp.com/go/assistance). In the United States: To contact HP by phone, call 1-800-334-5144. For continuous quality improvement, calls may be recorded or monitored. If you have purchased a Care Pack (service upgrade), see the Support & Drivers website (http://www8.hp.com/us/en/support-drivers.html). If the problem cannot be resolved at the website, call 1-800-633-3600. For more information about Care Packs, see the HP website (http://pro-aq-sama.houston.hp.com/services/cache/10950-0-0-225-121.html). Technician notes 5

Introduction Overview The HP Ethernet 10Gb 2-port 530SFP+ Adapter is a dual port, 10 Gb SFP+ adapter. The HP Ethernet 10Gb 2-port 530SFP+ Adapter is field replaceable and features Energy Efficient Ethernet and IEEE 1588/Precision Time Protocol support, PCI Express v2.0, and a sea of sensors that allows temperature monitoring of the option for optimized server power consumption. For more information about the HP Ethernet 10Gb 2-port 530SFP+ Adapter, see the HP website (http://www.hp.com/go/proliantnics). LED indicators The HP Ethernet 10Gb 2-port 530SFP+ Adapter has two ports with LED indicators for Link (L) and Activity (A) for each port. A standard-height bracket is shown below with SFP+ ports and LED indicators. The HP Ethernet 10Gb 2-port 530SFP+ Adapter LED indicators operate as described in the following table. Item LED indicator Status Description 1 Link Off No link to the adapter is established. The adapter is not receiving power or the cable connection is faulty. On (Orange) Link to the adapter is established at 10 Gb/s. The adapter is receiving power and the cable connection is good. 2 Activity Off Indicates no network activity on the link. On (Green) Indicates network activity on the link. The adapter is sending or receiving network data at up to 10 Gb/s. Introduction 6

Installing an adapter Installation overview This section describes installation precautions, how to install the adapter, and how to connect the network cable. WARNING: To reduce the risk of personal injury or damage to the equipment, consult the safety information and user documentation provided with the server before attempting the installation. Some servers contain high energy, high circuits, moving parts (such as fan blades), or any combination of these hazards, that may be exposed if covers and access panels are removed while the product is powered. These products are intended to be serviced only by qualified personnel who have been trained to deal with these hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided for the purpose of guarding against these hazardous conditions. WARNING: Installation of this adapter should be performed by individuals who are both qualified in the servicing of computer equipment, and trained in the hazards associated with products capable of producing hazardous energy levels. This adapter is intended to be installed in Certified (UL or CSA) ITE equipment having instructions for adding and removing user installed components such as PCI, PCI-X, and PCI Express devices. Refer to the equipment instructions to verify that it is suitable for user installed components and that it has the power capacity to support all of the installed components. NOTE: Before removing the cover of your server, refer to the HP documentation for the proper methods for installing a PCI Express card and avoiding electric shock hazards. Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: Avoid hand contact by transporting and storing products in static-safe containers. Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. Place parts on a grounded surface before removing them from their containers. Avoid touching pins, leads, or circuitry. Always be properly grounded when touching a static-sensitive component or assembly. Installing an adapter 7

Installing an adapter in a server For additional information on how to safely install a PCI Express card in the server, see the HP ProLiant server documentation. CAUTION: If the server is not PCI Hot Plug compliant, power it down and unplug the power cord from the power outlet before removing the server access panel. Failure to do so may damage the adapter or server. 1. Power down the server. 2. Remove the power cord and server access panel. WARNING: To reduce the risk of personal injury from a hot component, allow the surface of the option card to cool before touching it. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. 3. Identify the PCI Express option slot in which the adapter is to be installed. If a low profile option slot is to be used, install the low profile bracket onto the adapter. 4. Remove the cover bracket from the PCI Express slot. 5. Firmly seat the adapter in the PCI Express slot and secure the adapter bracket. NOTE: For 1U type servers you may need to replace the standard profile bracket with a low profile bracket. See Installing a low profile bracket (on page 8). 6. Replace the access panel and plug in the power cord. Installing a low profile bracket You may have to install a low profile bracket to complete the product installation. The low profile bracket replaces the existing standard profile bracket shipped on the product. To install a low profile bracket: Installing an adapter 8

1. Using a correctly sized slotted screwdriver, carefully remove the two board lock screws located at the top and bottom of the connector. 2. Remove the standard profile bracket and place the low profile bracket over the connector. Be careful not to damage the connector or bind the low profile bracket to the connector. Connecting the network cable The HP Ethernet 10Gb 2-port 530SFP+ has two SFP+ ports. These ports support either of the following: Direct Attached Copper (DAC) cables Optical Modules to be used with fiber optic cables See Cable specifications (on page 10) for the maximum cable length supported. To connect the HP Ethernet 10Gb 2-port 530SFP+ to the network, complete the following steps: 1. Orient the SFP+ optical module or DAC cable so that the Gold Fingers on the edge of the circuit board is located closest to the option card circuit board. 2. Install the SFP+ optical module or DAC cable all the way into the SFP+ socket until it clicks into place and is securely latched. 3. If an optical module is used, remove the protective cover and connect the fiber optic cable. Installing an adapter 9

Specifications Cable specifications SFP+ module type 10GBASE-SR (short range) Optical Module 10GBASE-CR with Direct Attached Copper (DAC) cable Cable Connector Type Wavelength (nm), type of cable LC 850, Multi-Mode Fiber (MMF) SFP+ N/A, Twin Axial Copper Core Size (microns, µm) 62.5 62.5 50 50 50 24 to 28 AWG, depending on length and manufacturer Cable grade Minimum modal bandwidth (MHz-km) ( FDDI ) OM1 OM2 OM3 160 200 400 500 2000 N/A N/A 7 Maximum Cable Length (meters) 26 33 66 82 300 General specifications Specification Controller Data rate PCI bus Connectors Dimensions (LxW) Value Broadcom 57810S 10 Gb/s per port, 20 Gb/s combined, full-duplex PCI Express x8 Gen3 2 10Gb SFP+ 5.2 x 2.7 inches (13.208 cm x 6.89 cm) without bracket Compliance Compliance IEEE Safety Standard IEEE802.3, IEEE802.3ap, IEEE802.3xx, IEEE802.2x, IEEE802.3ad, 802.1Qaz, 802.1Qau, 802.1Qbb, 802.1Qbg, 802.1Qbh UL Mark (US and Canada) EN 60950 Specifications 10

Compliance Standard Other PCIe v3.0 RoHS 6 of 6 IPv4, IPv6 CE Microsoft Windows Hardware Quality Labs Server Design Guide version 3.0 SNMP IPv4, TCP and UDP Checksum Offload IPv4/IPv6 TCP, Large Send Offload Receive-Side Scaling Jumbo Frames up to 9000 Bytes Power and environmental specifications Specification Value Operating Temperature 0 to 55 C (32 to 131 F) Humidity 10 to 90% relative humidity, non-condensing Non-operating Temperature -65 to 85 C (-85 to 185 F) Humidity 5 to 95% relative humidity, non-condensing Power 4 W typical, 9 W maximum Specifications 11

Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product. Federal Communications Commission Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected. Consult the dealer or an experienced radio or television technician for help. Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user s authority to operate the equipment. European Union regulatory notice Products bearing the CE marking comply with the following EU Directives: Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Ecodesign Directive 2009/125/EC, where applicable CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP. Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product Regulatory compliance notices 12

family and available (in English only) either within the product documentation or at the following HP website (http://www.hp.eu/certificates) (type the product number in the search field). The compliance is indicated by one of the following conformity markings placed on the product: For non-telecommunications products and for EU harmonized telecommunications products, such as Bluetooth within power class below 10mW. For EU non-harmonized telecommunications products (If applicable, a 4-digit notified body number is inserted between CE and!). Please refer to the regulatory label provided on the product. The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, GERMANY. Canadian notice (Avis Canadien) This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Korean class B notice Japanese class B notice Disposal of waste equipment by users in private households in the European Union Regulatory compliance notices 13

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Regulatory compliance notices 14

Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: Avoid hand contact by transporting and storing products in static-safe containers. Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. Place parts on a grounded surface before removing them from their containers. Avoid touching pins, leads, or circuitry. Always be properly grounded when touching a static-sensitive component or assembly. Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin. Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. Use conductive field service tools. Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact an authorized reseller. Electrostatic discharge 15

Acronyms and abbreviations CSA Canadian Standards Association IPv4 Internet Protocol version 4 IPv6 Internet Protocol version 6 PCIe peripheral component interconnect express PCI-X peripheral component interconnect extended RoHS Restriction of Hazardous Substances SFP+ small form-factor pluggable - plus UDP User Datagram Protocol UTP unshielded twisted pair Acronyms and abbreviations 16

Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (mailto:docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback. Documentation feedback 17