HP NC523SFP 10Gb 2-port Ethernet Server Adapter User Guide
|
|
|
- Florence Jordan
- 9 years ago
- Views:
Transcription
1 HP NC523SFP 10Gb 2-port Ethernet Server Adapter User Guide Part Number September 2010 (First Edition)
2 Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Intended audience This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
3 Contents Technician notes... 4 Warnings, cautions, and notes... 4 Downloading files... 5 HP contact information... 5 Introduction... 6 Overview... 6 LED indicators... 6 Installing an adapter... 8 Installation overview... 8 Preventing electrostatic discharge... 8 Installing an adapter in a server... 9 Installing a low profile bracket... 9 Connecting the network cable Specifications Cable specifications General specifications Compliance Power and environmental specifications Regulatory compliance notices Regulatory compliance identification numbers Federal Communications Commission notice European Union regulatory notice Canadian notice Korean class A notice Japanese class A notice Disposal of waste equipment by users in private households in the European Union Electrostatic discharge Preventing electrostatic discharge Grounding methods to prevent electrostatic discharge Acronyms and abbreviations Index... 17
4 Technician notes Warnings, cautions, and notes WARNING: Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard. WARNING: To reduce the risk of electric shock, personal injury, and damage to the equipment: Do not attempt to service any parts of the equipment other than those specified in the following procedure. Any other activities may require that you shut down the server and remove the power cord. Installation and maintenance of this product must be performed by individuals who are knowledgeable about the procedures, precautions and hazards associated with the product. WARNING: To reduce the risk of electric shock or damage to the equipment: Do not disable the power cord grounding plug. The grounding plug is an important safety feature. Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times. Unplug the power cord from the power supply to disconnect power to the equipment. Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server. This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server. CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only. NOTE: Any indications of component replacement or printed wiring board modifications may void any warranty. Technician notes 4
5 Downloading files 1. Go to the HP website ( 2. Select Download drivers and software (and firmware). 3. Type the adapter name in the For product box and then click Go. For example, type NC523SFP. 4. Download the drivers, firmware, or documentation as needed. HP contact information For the name of the nearest HP authorized reseller: See the Contact HP worldwide (in English) webpage ( For HP technical support: In the United States, for contact options see the Contact HP United States webpage ( To contact HP by phone: o o Call HP-INVENT ( ). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored. If you have purchased a Care Pack (service upgrade), call For more information about Care Packs, refer to the HP website ( In other locations, see the Contact HP worldwide (in English) webpage ( Technician notes 5
6 Introduction Overview The HP NC523SFP 10Gb 2-port Ethernet Server Adapter is a dual port PCI Express (PCIe) 10 Gigabit ProLiant Ethernet adapter. The network connection is made through two 10Gbps Ethernet SFP+ ports. In addition to standard HP network server adapter features, the NC523SFP is capable of supporting teaming for load balancing and failover, TCP checksum and segmentation (LSO) offload capability, VLAN tagging, jumbo frames, IPv6, and other features. The NC523SFP can be installed in either standard or low profile slots. For more information about the HP NC523SFP 10Gb 2-port Ethernet Server Adapter, see the HP website ( LED indicators The NC523SFP adapter has two ports with LED indicators for Link (L) and Activity (A) for each port. Standard-height bracket is shown below with the SFP+ ports and LED indicators. The NC523SFP 10 Gigabit Server Adapter LED indicators operate as described in the following table. Item LED indicator Status Description 1 Activity Off Indicates no network activity on the link. Flashing (Green) Indicates network activity on the link. The adapter is sending or receiving network data at up to 10 Gbps. 2 Link Off No link to the adapter is established. The adapter is not receiving power or the cable connection is faulty. On (Yellow) Link to the adapter is established. The adapter is receiving Introduction 6
7 Item LED indicator Status Description power and the cable connection is good. Introduction 7
8 Installing an adapter Installation overview This section describes installation precautions, how to install the adapter, and how to connect the network cable. WARNING: To reduce the risk of personal injury or damage to the equipment, consult the safety information and user documentation provided with the server before attempting the installation. Many servers are capable of providing energy levels that are considered hazardous and are intended to be serviced only by qualified personnel who have been trained to deal with these hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided for the purpose of removing these hazardous conditions. WARNING: Installation of this adapter should be performed by individuals who are both qualified in the servicing of computer equipment, and trained in the hazards associated with products capable of producing hazardous energy levels. This adapter is intended to be installed in Certified (UL or CSA) ITE equipment having instructions for adding and removing user installed components such as PCI, PCI-X, and PCI Express devices. Refer to the equipment instructions to verify that it is suitable for user installed components and that it has the power capacity to support all of the installed components. NOTE: Before removing the cover of your server, refer to the HP documentation for the proper methods for installing a PCI Express card and avoiding electric shock hazards. Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: Avoid hand contact by transporting and storing products in static-safe containers. Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. Place parts on a grounded surface before removing them from their containers. Avoid touching pins, leads, or circuitry. Always be properly grounded when touching a static-sensitive component or assembly. Installing an adapter 8
9 Installing an adapter in a server See the HP ProLiant server documentation for additional information on how to safely install a PCI Express card in the server. CAUTION: If the server is not PCI Hot Plug compliant, power it down and unplug the power cord from the power outlet before removing the server access panel. Failure to do so may damage the adapter or server. 1. Power down the server. 2. Remove the power cord and server access panel. WARNING: To reduce the risk of personal injury from a hot component, allow the surface of the option card to cool before touching it. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. 3. Identify the PCI Express option slot in which the adapter is to be installed. If a low profile option slot is to be used, install the low profile bracket onto the adapter. 4. Remove the cover bracket from the PCI Express slot. 5. Firmly seat the adapter in the PCI Express slot and secure the adapter bracket. NOTE: For 1U type servers you may need to replace the standard profile bracket with a low profile bracket. See Installing a low profile bracket. 6. Replace the access panel and plug in the power cord. Installing a low profile bracket You may have to install a low profile bracket prior to the product installation. The low profile bracket replaces the existing standard profile bracket shipped on the product. Installing an adapter 9
10 1. Using a correctly sized Phillips head screwdriver, carefully remove the two board lock screws located above and below the SFP+ connectors. 2. Remove the standard profile bracket and place the low profile bracket over the connectors. Be careful not to damage the connectors or bend the low profile bracket. 3. Reinstall the two Phillips screws. Connecting the network cable The NC523SFP has two SFP+ ports. These ports support either of the following: Direct Attached Copper (DAC) cables Optical Modules to be used with fiber optic cables See Cable specifications (on page 11) for the maximum cable length supported. To connect the NC523SFP to the network, complete the following steps: 1. Orient the SFP+ optical module or DAC cable so that the Gold Fingers on the edge of the circuit board is located closest to the option card circuit board. 2. Install the SFP+ optical module or DAC cable all the way into the SFP+ socket until it clicks into place and is securely latched. 3. If an optical module is used, remove the protective cover and connect the fiber optic cable. Installing an adapter 10
11 Specifications Cable specifications SFP+ module type Cable Connector Type Wavelengt h (nm), type of cable Core Size (microns, µm) Cable grade Minimum modal bandwidth (MHz-km) Maximum Cable Length (meters) 10GBASE- SR (short range) Optical Module LC 850, Multi- Mode Fiber (MMF) ( FDDI ) OM1 OM2 OM GBASE- CR with Direct Attached Copper (DAC) cable SFP+ N/A, Twin Axial Copper 24 to 28 AWG, depending on length and manufacture r N/A N/A 7 General specifications General specifications Controller Data rate PCI bus Connectors Dimensions (LxW) Value QLOGIC clom Gbps, full-duplex 8 Lane (x8) PCI Express Gen 2, compatible with x4 and x8 bus widths 2 SFP+ 6.6 x 2.7 inches ( cm x 6.89 cm) without bracket Compliance Compliance IEEE Safety Standard IEEE802.3x, IEEE802.3ad, IEEE802.1p, IEEE802.1q, IEEE802.3az, IEEE802.3ae, IEEE802.3ap, IEEE802.1qau UL Mark (US and Canada) EN Specifications 11
12 Compliance Standard Other PCIe v2.0 RoHS 6 of 6 IPv4, IPv6 CE Microsoft WHQL (Windows Hardware Quality Labs) Server Design Guide version 3.0 (SDG 3.0) SFF Gigabit Small Form Factor Pluggable Module SFP+ SNMP IPv4/IPv6 TCP, UDP checksum Offload IPv4/IPv6 TCP, Large Send Offload IPv4/IPv6 TCP, Large Receive Offload Receive-Side Scaling Jumbo Frames up to 9000 Bytes Power and environmental specifications Power and environmental specifications Value Operating Temperature 0 to 55 C (0 to 131 F) Humidity 15 to 80% relative humidity, non-condensing. Non-operating Temperature -40 to 70 C (0 to 158 F) Humidity 10 to 90% relative humidity, non-condensing. Power 17 Watts typical, 19 Watts maximum Specifications 12
13 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product. Federal Communications Commission notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense. European Union regulatory notice Products bearing the CE marking comply with the following EU Directives: Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC Ecodesign Directive 2009/125/EC, where applicable CE compliance of this product is valid if powered with the correct CE-marked AC adapter provided by HP. Compliance with these directives implies conformity to applicable harmonized European standards (European Norms) that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available (in English only) either within the product documentation or at the following HP website ( (type the product number in the search field). The compliance is indicated by one of the following conformity markings placed on the product: For non-telecommunications products and for EU harmonized telecommunications products, such as Bluetooth within power class below 10mW. Regulatory compliance notices 13
14 For EU non-harmonized telecommunications products (If applicable, a 4-digit notified body number is inserted between CE and!). Please refer to the regulatory label provided on the product. The point of contact for regulatory matters is Hewlett-Packard GmbH, Dept./MS: HQ-TRE, Herrenberger Strasse 140, Boeblingen, GERMANY. Canadian notice This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Korean class A notice Japanese class A notice Disposal of waste equipment by users in private households in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. Regulatory compliance notices 14
15 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device. To prevent electrostatic damage: Avoid hand contact by transporting and storing products in static-safe containers. Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations. Place parts on a grounded surface before removing them from their containers. Avoid touching pins, leads, or circuitry. Always be properly grounded when touching a static-sensitive component or assembly. Grounding methods to prevent electrostatic discharge Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm ±10 percent resistance in the ground cords. To provide proper ground, wear the strap snug against the skin. Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. Use conductive field service tools. Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part. For more information on static electricity or assistance with product installation, contact an authorized reseller. Electrostatic discharge 15
16 Acronyms and abbreviations CSA Canadian Standards Association DMA direct memory access IEEE Institute of Electrical and Electronics Engineers iscsi Internet Small Computer System Interface PCI Express Peripheral Component Interconnect Express SFP small form-factor pluggable Acronyms and abbreviations 16
17 Index A adapter LEDs 6 adapters 6 B bracket, low profile 9 C cables, networking 10 compliance 11, 13 contact information 5 D disposal, waste 14 downloading files 5 S specifications 11 standards 13 T technical notes 4 V ventilation 4 W warnings 4 E electrostatic discharge 8, 15 F features 6 G grounding methods 15 L LC connector 10 LEDs 6 low profile bracket 9 P PCI (peripheral component interface) 8 R regulatory compliance notices 13, 14 Index 17
HP Ethernet 10Gb 2-port 530SFP+ Adapter User Guide
HP Ethernet 10Gb 2-port 530SFP+ Adapter User Guide Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the
HP SuperSpeed USB 3.0 PCIe x1 Card. User Guide
HP SuperSpeed USB 3.0 PCIe x1 Card User Guide Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
HP NC7170 Dual Port PCI-X 1000T Gigabit Server Adapter User Guide. June 2007 (Second Edition) Part Number 331899-00B
HP NC7170 Dual Port PCI-X 1000T Gigabit Server Adapter User Guide June 2007 (Second Edition) Part Number 331899-00B 2003, 2007 Hewlett-Packard Development Company, L.P. Intel is a trademark of Intel Corporation
QuickSpecs. HP NC552SFP 10Gb 2-port Ethernet Server Adapter. HP NC552SFP 10Gb 2-port Ethernet Server Adapter. Overview
Overview The NC552SFP is an eight lane (x8) PCI Express (PCIe) 10 Gigabit network solution offering optimal throughput. This PCI Express Gen 2 adapter from Emulex ships with two SFP+ (Small Form-factor
HP POS Keyboard with MSR for Point of Sale System. User Guide
HP POS Keyboard with MSR for Point of Sale System User Guide Copyright 2008 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft,
HP TFT7600 G2 Rackmount Keyboard Monitor KVM Console User Guide
HP TFT7600 G2 Rackmount Keyboard Monitor KVM Console User Guide Part Number 615930-001 June 2010 (First Edition) Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein
HP STORAGEWORKS PCI TO FC HOST BUS ADAPTER
You can read the recommendations in the user guide, the technical guide or the installation guide for HP STORAGEWORKS PCI TO FC HOST BUS ADAPTER. You'll find the answers to all your questions on the HP
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE
Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards 1.2 PACKAGE
HP SATA/SAS hard drive and Solid State Drive installation
HP SATA/SAS hard drive and Solid State Drive installation This document describes how to install Serial ATA (SATA) and Serial Attached SCSI (SAS) hard drives or Solid State Drives (SSD) in an internal
HP ProLiant Moonshot Cartridge User and Maintenance Guide
HP ProLiant Moonshot Cartridge User and Maintenance Guide Abstract This document is for the person who installs, administers, services, and troubleshoots cartridges. This guide describes identification
About the HotWire 7900 10-Slot Standalone Shelf
TM HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions Document Number 7900-A2-GN10-10 About the HotWire 7900 10-Slot Standalone Shelf The HotWire 7900 10-Slot Standalone Shelf is designed
BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES
NOTES BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability Quick Start Guide This is a Class A device and is not intended for use in a residential environment. Important
Models HP NC552SFP 10Gb 2-port Ethernet Server Adapter 614203-B21
Overview The NC552SFP is an eight lane (x8) PCI Express (PCIe) 10 Gigabit network solution offering the highest bandwidth available in a ProLiant Ethernet adapter. This dual port PCI Express Gen 2 adapter
TG-3468 Gigabit PCI Express Network Adapter
TG-3468 Rev:2.0.0 1910010580 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks
Small form factor bay converter and hard drive installation
Small form factor bay converter and hard drive installation HP xw6600 and HP xw8600 Workstations This document describes how to convert HP xw6600 and HP xw8600 Workstation 3.5-inch hard drive bays to hold
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install
HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install Carrier-Grade Instructions HP Part Number: AM275-9001A Published: July 2012 Edition: 3 Copyright 2009, 2012 Hewlett-Packard Development Company,
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
HP TFT7600 Rackmount Keyboard and Monitor User Guide
HP TFT7600 Rackmount Keyboard and Monitor User Guide Part Number 365378-002 August 2007 (Second Edition) Copyright 2005, 2007 Hewlett-Packard Development Company, L.P. The information contained herein
4 Port PCI Express Gigabit Ethernet PoE PSE Network Card
4 Port PCI Express Gigabit Ethernet PoE PSE Network Card ST4000PEXPSE *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía
Technical Support. Support Information
Technical Support Please refer to the Support Information card that shipped with your product. By registering your product at www.netgear.com/register, we can provide you with faster expert technical support
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
QuickSpecs. Models. HP NC375T PCI Express Quad Port Gigabit Server Adapter. HP NC375T PCI Express Quad Port Gigabit Server Adapter.
QuickSpecs Overview In today's resource constrained environments, there is a predominant need to simplify infrastructure, improve manageability, optimize network performance and lower the cost of computing.
HP NC364T PCI Express Quad Port Gigabit Server Adapter Overview
Overview The HP NC364T PCI Express Quad-Port Gigabit Server features four 10/100/1000T Gigabit Ethernet ports on a single card, saving valuable server I/O slots for other purposes. The four ports provide
HP 22-in-1 Media Card Reader
HP 22-in-1 Media Card Reader Introduction This document describes how to install the HP 22-in-1 Media Card Reader into an HP Workstations adapter bracket, and then install the media card reader and bracket
HP USB Network Print Adapter. User Guide
HP USB Network Print Adapter User Guide Copyright 2007 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company notices The information contained in this document is subject to change without
SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide
Introduction This guide is to assist the reader with the most basic form of installation and connection to switches in this series. As there is more than one switch in this series, the diagrams might slightly
PCI Express 10GBase-LR/SR/LRM Fiber Network Card with Open SFP Slot
PCI Express 10GBase-LR/SR/LRM Fiber Network Card with Open SFP Slot PEX10000SFP *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)
Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide
Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608 Installation Guide Introduction The NETGEAR 5/8-Port Gigabit Ethernet Switch Model GS605 / GS608 provides you with a high-speed, reliable, easy-to-use
16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide
16-port Gigabit Switch 10/100/1000 Mbps GS116 Installation Guide Introduction The NETGEAR 16-port Gigabit Switch Model GS116 provides you with a low-cost, reliable, high-performance switch to connect up
Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide. 613-001352 Rev. A
Gigabit eco-friendly Ethernet Switch AT-GS900/8 Installation Guide 613-001352 Rev. A Copyright 2010 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior
Upgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
Compaq Presario Desktop Products. Upgrading and Servicing Guide
Compaq Presario Desktop Products Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide
Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide Thank you for buying an Intel RAID Maintenance Free Backup Unit 4. The Intel RAID Maintenance Free Backup Unit 4 supports the Intel
Full_IG.book Page 1 Monday, January 9, 2012 6:11 PM. ProSafe 24 Port Gigabit Switch Installation Guide
Full_IG.book Page 1 Monday, January 9, 2012 6:11 PM ProSafe 24 Port Gigabit Switch Installation Guide Full_IG.book Page 2 Monday, January 9, 2012 6:11 PM 2011 NETGEAR, Inc. All rights reserved. No part
TG-3468 Gigabit PCI Express Network Adapter
TG-3468 Rev:2.1.0 1910010908 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks
Memory Modules User Guide
Memory Modules User Guide Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services
HP Optical Bay Hard Drive Bracket
HP Optical Bay Hard Drive Bracket Introduction This document describes how to install 8.89 cm (3.5 inch) hard drives in the HP optical bay hard drive bracket and install the bracket in the optical drive
QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview
Overview Fixed Cord PDUs and Extension Bars have a unique architecture designed specifically for 1U fixed rail servers (HP ProLiant DL360, HP ProLiant DL320, HP ProLiant DL140). This new design consists
PE10G2T Dual Port Fiber 10 Gigabit Ethernet TOE PCI Express Server Adapter Broadcom based
PE10G2T Dual Port Fiber 10 Gigabit Ethernet TOE PCI Express Server Adapter Broadcom based Description Silicom 10Gigabit TOE PCI Express server adapters are network interface cards that contain multiple
Perle Protocol Transparent Media Converter Modules
Perle Protocol Transparent Media Converter Modules Installation Guide C-4GPT-DSFP CM-4GPT-DSFP Part# 5500335-10 Overview This document contains instructions necessary for the installation and operation
HP ProLiant DL165 G7 Server. Installation Instructions
HP ProLiant DL165 G7 Server Installation Instructions Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 HDD Item 1 Thumbscrews for rack mounting 2 Drive status
Wall-Mounting your HP computer. User Guide
Wall-Mounting your HP computer User Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105
5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105 Installation Guide Introduction The NETGEAR 5-Port Gigabit Ethernet Switch Model GS105 provides you with a low-cost, reliable, high-performance switch
Hard Disk Drive (HDD)
Installation Instructions Hard Disk Drive (HDD) Catalog Number 6189V-35HDDST80, 6189V-35HDDST160 Topic Page About This Publication 1 Important User Information 2 Electrostatic Discharge (ESD) Precautions
QuickSpecs. Models HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter 629142-B21. HP FlexFabric 10Gb 2-port 554FLR-SFP+ Adapter.
Overview The provides Ethernet functionality; or Ethernet and iscsi, or Fibre Channel Over Ethernet (FCoE) or FlexFabric connectivity in a FlexibleLOM form factor designed for select HP ProLiant Gen8 rack
QuickSpecs. HP 480/277 Volt Solutions. Overview
Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute
DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide
DSA E-Series E2600, DE1600, DE6600 en Storage System Site Preparation Guide DSA E-Series Table of Contents en 3 Table of contents 1 About This Guide 5 2 Specifications of the E2600 Controller-Drive Tray
1-Port DS3 IMA Module Description and Technical Specifications. The 1-Port DS3 IMA module is illustrated in Figure 1. FAIL ACTIVE DS3 IMA L0S
1-Port DS3 IMA Module Description and Technical Specifications Purpose of This Document This document identifies and describes the 1-Port DS3 IMA module and related safety information. It also includes
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Cisco TelePresence MCU 4500 Series safety and compliance information
Cisco TelePresence MCU 4500 Series safety and compliance information On this page: Safety information symbols Operating guidelines Safety warnings Technical specifications Compliance information WEEE information
MoCA Adapter MC1001 v2 Installation Guide
Technical Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on the label of your product and use it to register your product at www.netgear.com/register.
IP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
HP Smart Array B110i SATA RAID Controller User Guide
HP Smart Array B110i SATA RAID Controller User Guide Part Number 531480-003 March 2010 (Third Edition) Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is
PCI Express USB 2.0 Adapter Card
PEXUSB400 Instruction Manual PCI Express USB 2.0 Adapter Card 4-Port (Independent) PCI Express to High Speed USB 2.0 Adapter Card FCC Compliance Statement This equipment has been tested and found to comply
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
Zebra RW 420 Mobile Battery Eliminator Kits
Zebra Technologies Corporation 475 Half Day Road, Suite 500 Lincolnshire, IL 60069 USA Zebra RW 420 Mobile Battery Eliminator Kits Installation Instructions September, 2010 RW 420 Mobile Battery Eliminator
Kvaser Mini PCI Express User s Guide
Kvaser Mini PCI Express User s Guide Copyright 2013-2014 Kvaser AB, Mölndal, Sweden http://www.kvaser.com Printed Sunday 28 th September, 2014 We believe that the information contained herein was accurate
HP UPS T1000/1500 User Guide
HP UPS T1000/1500 User Guide April 2006 (First Edition) Part Number 404317-001a Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP R12000 and R18000 DirectFlow UPS User Guide
HP R12000 and R18000 DirectFlow UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R12000 and R18000 DirectFlow UPS. This document is for the
QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview
Overview The Tower UPS "G2" models are the next generation HP tower UPSs with USB support. These new UPSs are designed to provide advanced power protection (or increased uptime and data corruption avoidance)
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based
PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based Description Silicom s quad port Copper 10 Gigabit Ethernet Bypass server adapter is a PCI-Express X8 network interface
DGE-528T Gigabit Ethernet PCI Adapter User Manual
D-Link DGE-528T Gigabit Ethernet PCI Adapter User Manual Rev.4.0 1 Table of Contents 1. Introduction... 3 System Requirement...3 Features...4 Driver Support...4 2. Installation... 5 Unpack and Inspect...5
Memory Modules. Document Part Number: 407947-001. This guide explains how to replace and upgrade memory in the computer. May 2006
Memory Modules Document Part Number: 407947-001 May 2006 This guide explains how to replace and upgrade memory in the computer. Contents 1 Adding or replacing memory modules Adding or replacing a memory
Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE
Aura SSD for the 2013 Apple Mac Pro INSTALLATION GUIDE TABLE OF CONTENTS 1. INTRODUCTION...1 1.1 SYSTEM REQUIREMENTS 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS MANUAL 2. INSTALLATION...2 2.1 PREPARING THE MAC
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
Stretch DisplayPort TM
Stretch DisplayPort TM User s Manual (M1-5000) Doc No. : OEC-DP130903 / Rev1.2 Manual Contents Manual Contents 1-0 Welcome!, Product Description 1-1 System Requirements for Setup 1-2 Installation 1-3 Troubleshooting,
BladeRunner 4U Blade Server User Manual. December 2004 (Revision A)
BladeRunner 4U Blade Server User Manual December 2004 (Revision A) Copyright Notice The copyright in all material provided in this User Manual is held by Penguin Computing Inc. or by the original creator
Hardware Reference Guide HP gt7720/gt7725 Thin Client
Hardware Reference Guide HP gt7720/gt7725 Thin Client Copyright 2008 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows
IDE ATA/133 Controller
IDE ATA/133 Controller 2 Port PCI ATA-133 IDE Adapter Card PCIIDE2 Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class
ProLiant DL380 Generation 2 Server Maintenance and Service Guide
ProLiant DL380 Generation 2 Server Maintenance and Service Guide Second Edition (June 200) Part Number 203840-002 Spare Part Number 228520-00 Compaq Computer Corporation Notice 200 Compaq Computer Corporation
Gateway Port Replicator User Guide
Gateway Port Replicator User Guide Using the Port Replicator Identifying features Connecting and disconnecting the port replicator 1 Using the Port Replicator Top Power button Component Icon Description
Conference Phone UserÕs Manual. Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc.
Part No. 54-2070-01R1 Printed in Korea. 2002 Bogen Communications, Inc. UserÕs Manual Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide
Intel RAID Module RMS3CC080/ RMS3CC040 and Intel RAID Maintenance Free Backup Unit 5 Quick Installation User's Guide Thank you for buying an Intel RAID Module. Your Intel RAID Module provides reliability,
This is a product of VCCI Class B Compliance
FCC Warning This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
Power Supply Guide Version 1.0 for D-Show
Power Supply Guide Version 1.0 for D-Show Digidesign 2001 Junipero Serra Boulevard Daly City, CA 94014-3886 USA tel: 650 731 6300 fax: 650 731 6399 Technical Support (USA) tel: 650 731 6100 fax: 650 731
Regulatory Compliance Statement
Regulatory Compliance Statement 0560 EU Declaration of Conformity The declaration of conformity may be consulted at www.kobo.com/userguides SAR Limits The exposure standard for wireless devices employs
HP 4 Gb PCI-X 2.0 Host Bus Adapters Overview
Models HP FC2143 4Gb PCI-X 2.0 HBA HP FC2243 Dual 4Gb PCI-X 2.0 HBA HP FC1143 4Gb PCI-X 2.0 HBA HP FC1243 Dual 4Gb PCI-X 2.0 HBA 4Gb, PCI-X-to-Fibre Host Bus Adapter for Windows and Linux. (Emulex LP1150)
4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide
4-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS104 Installation Guide 4500 Great America Parkway Santa Clara, CA 95054 USA Phone: 1-888-NETGEAR E-mail: [email protected] www.netgear.com Technical
LSI MegaRAID SAS 8888ELP Host Bus Adapter installation
LSI MegaRAID SAS 8888ELP Host Bus Adapter installation Introduction This document describes how to install the LSI MegaRAID SAS 8888ELP Host Bus Adapter (HBA) in HP and xw series Workstations. Procedures
DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual
DE1600 DSA E-Series iscsi Disk Arrays en Installation Manual DE1600 DSA E-Series iscsi Disk Arrays Table of Contents en 3 Table of Contents 1 Safety Precautions 4 1.1 Warning Notices 4 1.2 Caution Notices
Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: 022808 PN: 883884-07L Rev. A
Installation Guide Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit Issue: 022808 PN: 883884-07L Rev. A ii Copyright Notice 2008, Wyse Technology Inc. All rights reserved. This manual and the
4 Port PCI Express Low Profile High Speed USB Card
4 Port PCI Express Low Profile High Speed USB Card PEXUSB4DP DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario - es.startech.com IT: Guida per
USB 3.0 PCI Express. 2-Ports Host Controller Card. User Manual. www.hamletcom.com HUSB302PCX
USB 3.0 PCI Express 2-Ports Host Controller Card User Manual HUSB302PCX www.hamletcom.com Index 1. INTRODUCTION... 4 2. INSTALLATION... 5 2.1. HARDWARE INSTALLATION...5 2.2. DRIVER INSTALLATION (WINDOWS
Triple Expansion Chassis
Triple Expansion Chassis AP9604 Installation Manual Contents Introduction............................. 1 Installation.............................. 2 Power Considerations...................... 5 Operations..............................
PCI Express USB Card. PCI Express 4 Port USB 2.0 card PEX400USB2. Instruction Manual. Actual product may vary from photo
PCI Express USB Card PCI Express 4 Port USB 2.0 card PEX400USB2 Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply with the limits for a Class
AXIS 291 1U Video Server Rack Installation Guide
AXIS 291 1U Video Server Rack Installation Guide About This Document This document describes how to install Axis blade video servers in the AXIS 291 1U Video Server Rack. Updated versions of this document
NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.
CAUTION: General Safety Instructions Use the following safety guidelines to help ensure your own personal safety and to help protect your equipment and working environment from potential damage. NOTE:
ES-3305P V2 / ES-3308P V2. Quick Installation Guide. 09-2013 / v1.0
ES-3305P V2 / ES-3308P V2 Quick Installation Guide 09-2013 / v1.0 1 COPYRIGHT Copyright Edimax Technology Co., Ltd. all rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S
Backup Battery Kit Install Guide: Intel Storage Controller AXXSCM3S A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products Intel Order Number: E13860-004 Disclaimer Information
BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1
BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved
PCI Express USB 3.0 Controller Adapter Card
PEXUSB3S2 Instruction Manual PCI Express USB 3.0 Controller Adapter Card 2-Port PCI Express SuperSpeed USB 3.0 Controller Adapter Card FCC Compliance Statement This equipment has been tested and found
Getting Started. rp5800, rp5700 and rp3000 Models
Getting Started rp5800, rp5700 and rp3000 Models Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows
UPGRADING AND SERVICING GUIDE
UPGRADING AND SERVICING GUIDE HPTouchSmart 610 PC Computer features may vary by model. Removing and Replacing a CD/DVD Drive...2 Removing the CD/DVD Drive... 2 Installing a New CD/DVD Drive... 5 Removing
IFS SP-PoE Splitter User Manual
IFS SP-PoE Splitter User Manual P/N 1069176-EN REV 1.01 ISS 01JUL10 2011 UTC Fire & Security. All rights reserved. Content Overview 2 Package contents 2 Introduction 3 Product Specifications 3 Hardware
4 Port PCIe 2.0 SATA III 6Gbps RAID Controller
4 Port PCIe 2.0 SATA III 6Gbps RAID Controller PEXSAT34SFF *actual product may vary from photos DE: Bedienungsanleitung - de.startech.com FR: Guide de l'utilisateur - fr.startech.com ES: Guía del usuario
