i410/i1010 AC/DC Current Clamp



Similar documents
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

323/324/325. Calibration Manual. Clamp Meter

HVAC Clamp Meter. Users Manual

Temperature Humidity Meter

MICROMAPPER. Users Manual. LAN Wiremap Checker

UT202A Operating Manual. Contents

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Multifunction Process Calibrator

10 Multimeter. Users Manual

How To Use The Visifault Visual Fault Locator

Instructions A Amp AC/DC Current Probe

K Standard Grade Ni-Cr vs Ni-Al (Chromel vs Alumel)

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Model UT33A: OPERATING MANUAL Table of Contents (1)

Model UT201/202: OPERATING MANUAL. Table of Contents

62 Max/62 Max + Infrared Thermometer

How To Use A Cdm250 Digital Multimeter

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

CO-220 Carbon Monoxide Meter

User's Guide. True RMS Industrial Multimeter

Owner s Manual & Safety Instructions

Manual Ranging MultiMeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Model 77 Series IV Digital Multimeter

Fluke 3000 FC Series Test Tools Technical Data

User Manual (English)

900 MHz Lightweight Wireless Stereo Headphones

1587/1577. Insulation Multimeters. Users Manual

AutoRanging Digital MultiMeter

Model UT58A/B/C: OPERATING MANUAL

MicroScanner 2. Cable Verifier. Getting Started Guide

Model 1756 Test Lead Kit

User Manual. CFG253 3 MHz Function Generator

ABCs of DMMs Multimeter features and functions explained Application Note

Model UT713 OPERATING MANUAL

Table of Contents. Page

115C and 117C. True-rms Multimeters. Users Manual

BroadBand PowerShield. User Manual

5616 Platinum Resistance Thermometer User s Guide

Instructional & Operating Manual

Ground Resistance Clamp-On Tester

Signal Manager Installation and Operation Manual

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Seven function digital multimeter

7 FUNCTION DIGITAL MULTIMETER

Fluke 3000 FC Series Test Tools Technical Data

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Model UT60A: OPERATING MANUAL. Table of Contents. Page

Mini Power Bank and Charger


INSTRUCTION MANUAL MODEL PCD-88

Advantium 2 Plus Alarm

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

NFC Communication Tray Model: HHX-IT3-Z

80PK-27 SureGrip TM Industrial Surface Temperature Probe

Limited Warranty Letter for BYD Photovoltaic Module

Geocontrol PRO INSTALLATION AND OPERATION MANUAL. Rev. 1 03/18/04 Part #

User s Guide. Publication number E June Copyright Agilent Technologies All Rights Reserved. E2697A 1 MΩ Impedance Adapter

Multimeter measurements on variable frequency drives using the new Fluke 289 DMM

PC Tab Security System INSTRUCTION MANUAL

12-Volt 10-Amp Regulated Power Supply

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Getting started with

User and Installation Guide

User Guide. Model Insulation Tester / Megohmmeter

Stretch DisplayPort TM

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Ceiling Mount Air Handler Manual

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

±15 V Current-Limited Power Supply

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Installation and Operation Guide for PD4000 Series Power Control Center

Weather Radio Alarm Clock

P O W E R S U P P L Y M A N U A L

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Leak Detection System

Sip/Puff Switch User Guide

Wireless Indoor/ Outdoor Thermometer

BACnet Automation Interface Module (Network Version)

Fluke Digital Multimeters Solutions for every need

Instructions & Safety Information Models A220-20D and A220-20L Version 2

64-CHANNEL INTEGRATED AMPLIFIER

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

User Guide. 4 wire Earth Resistance Tester Model GRT300

Alarm Clock USER GUIDE


Users Manual. Temperature Calibrator

Optical Wireless Mouse. User s Manual

TIG INVERTER INSTRUCTION MANUAL

TERMS AND CONDITIONS

INTRODUCTION SAFETY PRECAUTIONS/

Transcription:

/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating instructions before use and follow all safety instructions. Use the Current Clamp only as specified in the operating instructions, otherwise the clamp s safety features may not protect you. Adhere to local and national safety codes. Individual protective equipment must be used to prevent shock and arc blast injury where hazardous live conductors are exposed. Do not hold the Current Clamp anywhere beyond the tactile barrier. See Features and Connections. Before each use, inspect the Current Clamp. Look for cracks or missing portions of the clamp housing or output cable insulation. Also look for loose or weakened components. Pay particular attention to the insulation surrounding the jaws. Never use the clamp on a circuit with voltages higher than 600 V (CAT. III) or a frequency higher than 400 Hz () or 2 khz (i1010). CAT III equipment is designed to protect against transients in equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. Use extreme caution when working around bare conductors or bus bars. Contact with the conductor could result in electric shock. Use caution when working with voltages above 60 V dc, 30 V ac rms or 42 V ac peak. Such voltages pose a shock hazard. PN 617677 September 1996, Rev.2, 6/05 1996-2005 Fluke Corporation. All rights reserved. Printed in Thailand.

CLAMP METER TRUE RMS MULTIMETER Features and Connections A Jaw Lever B Jaw Centering Marks CAT 8 C ON Indicator D ON/OFF Switch E Zero Adjust F Battery Access G Output Cable H Tactile Barrier 76 Minimum voltmeter requirements: V ar001i.eps Accepts safetyshrouded banana plugs. Can display 1 mv (0.1 mv preferred) Accuracy 0.75 % Input impedance 1 MΩ, 100 pf.

CAT CLAMP METER CAT CLAMP METER TRUE RMS MULTIMETER Measuring DC Current Maximum: 400 A dc () or 1000 A dc (i1010) 76 mv ar002i.eps A Connect to voltmeter. B Select mv dc. C Set ON. D Adjust ZERO (jaws empty.) ar006i.eps E Clamp and center around conductor. F Read voltmeter (1 mv = 1 A.)

TRUE RMS MULTIMETER A A Measuring AC Current Maximum: 400 A ac rms () or 600 A ac rms (i1010) 4 5 6 3 7 2 8 1 9 0 10 Speed CAT ZERO CLAMP METER CAT ZERO CLAMP METER 76 V ar003i.eps A Connect to voltmeter. B Select mv ac (or V ac, but resolution may be limited to 1 A.) C Set ON. D Clamp and center around conductor. E Read voltmeter (1 mv = 1 A.)

CLAMP METER TRUE RMS MULTIMETER Testing the Battery CAT 76 V A Set OFF. B Select V dc. C 7.0 V dc = replace battery. (Voltmeter input impedance 1 MΩ) ar004i.eps Replacing the Battery For specified battery life, use an alkaline battery. 1. 2. 3. ar005i.eps

If the Current Clamp Does Not Work Check Battery = OK? Voltmeter connections? Voltmeter function/range? Correct Refer to Testing the Battery. Red to + or V Black to C mv dc mv ac (or V ac) Storage During longer periods of non-use (> 60 days), remove and store the battery separately. Cleaning Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Service and Parts The Current Clamp should be serviced only by a qualified service technician. For service information, contact your nearest Fluke dealer or service center. Symbols, May be used on HAZARDOUS LIVE conductors. T W X ) Equipment protected by double or reinforced insulation. Risk of Danger. Important information. See Instruction Sheet. Risk of Electric Shock. Complies with U.S. and Canadian standards: UL61010-1; CAN/CSA C22.2 No. 61010-1 (2004) & No. 61010-2-032 (2004) Inspected and licensed by TÜV Product Services. s ; Conforms to relevant Australian standards. N10140 P Conforms to IEC 61010-1 2nd Edition & IEC 61010-02-032 J B F Earth ground AC (Alternating Current) DC (Direct Current)

Specifications Operating Temperature -10 C to +50 C (14 F to 122 F) Storage Temperature -20 C to +60 C (-4 F to +140 F) Relative Humidity 0 % to 95 % (0 C to 30 C) 0 % to 75 % (30 C to 40 C) 0 % to 45 % (40 C to 50 C) Altitude Operating Non-operating 0 m 2000 m 0 m 12000 m Battery Type 9 V (alkaline) NEDA 1604 IEC 6F22 Battery Life 60 hrs typical (continuous with alkaline) Safety s Double Insulation, 600 V rms, CAT. III Current x Hz Product 240,000 Output Signal 1 mv per amp dc or ac Working Voltage 600 V rms, CAT. III maximum at input Maximum Conductor Size 1 ea. 30 mm (1.18 in.) diameter 2 ea. 25 mm (0.98 in.) diameter Load Impedance 1 MΩ, 100 pf Temperature Coefficient +/-(0.05 x accuracy per C (0 C 18 C, 28 C 50 C) Size 209 mm x 78 mm x 48 mm (3.09 in. x 8.21 in. x 1.87 in.) Weight 0.5 kg (17.6 oz.) Specified Current Range: Usable Current Range: DC Accuracy (zero 3.5 % + 0.5 A (0 A adjusted, conductor 400 A) centered) AC Accuracy 3.5 % + 0.5 A, 45 Hz 400 Hz, Crest Factor 3. (0 A 400 A) i1010 1 A 400 A ac rms * 1 A 600 A ac rms * 1 A 400 A dc 1 A 1000 A dc 0.5 A 400 A 0.5 A 1000 A 2.0 % + 0.5 A (0 A 1000 A) 2.0 % + 0.5 A, 45 Hz 400 Hz, Crest Factor 3. 3.0 % + 0.5 A, 400 Hz - 2 khz sine wave. (0 A 600 A) Bandwidth 3 khz 10 khz * With a true-rms voltmeter, the minimum ac current is limited to the low end of the specified mv ac range.

LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99