Technical Data Sheet W13. Edition 2005-03. Knauf Fire Walls



Similar documents
Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

PART 1 GENERAL 1.1 SECTION INCLUDES

Mold Preventing I nterior System

12.1 Schlüter -KERDI-BOARD

FireWall. High performance fireresistant. FireWall.

WATERPROOFING OF WET ROOMS

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Quality power tools since 1919 NEW GENERATION. Stirrers and mixing stations

UNDP-ACT-RFQ-15_06 REQUEST FOR QUOTATION [RFQ] REFURBISHMENT WORK AT FULBRIGHT CENTER (INCLUDING THE CONSTRUCTION OF INTERPRETATION BOOTHS)

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

GYPSUM AREA SEPARATION FIREWALLS GA

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Superform Products Ltd.

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Composite Panel Firewall Systems

Rockwool Flexi Insulation Application Guide

MERO Floor Systems - CleanRoom

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Excerpts from the Canadian National Building Code (NBC)

H-Stud Area Separation Wall System

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

pinta ACOUSTIC PANEL [1/7]

Manual lifting and handling

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

Ceilings without fi ller. VoglFuge / VoglJoint. Acoustic design ceilings

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Armanet BEKAERT. Armanet THE CONSTRUCTIVE IDEA. Render & plaster @@@

Waterproofing construction Joints

FIRE RATED GLAZING System Guide

Gypsum Board Systems Manual

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

NATIONAL INSTITUTE OF BIOLOGICALS

Improving the flood resistance of your home. Advice sheet 4: Flood-resilient walls.

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Installation Window Building In Details

Accessible planning and construction

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Beautifully Traditional

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Brick Veneer Construction

PANELIZED HOME INSTALLATION GUIDELINE

Retail Price List 2015

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

CertainTeed. Shaftliner For A rea Separation Firewalls

Mark Cramer Inspection Services, Inc.

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

FIREPROOF Panels Trimoterm

Fire Resistance of Brick Masonry

Residential Roofing Guide

Module 3.7. Thermal bridging

Window Installation Instructions

Clad Direct Glaze Window Installation Instructions

6.1 Schlüter -DITRA. Application and Function

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

SECTION STANDING SEAM METAL ROOF

Fire Barrier Duct Wrap 15A

Packaged Terminal Air Conditioner Wall Sleeve Installation

Sun Windows General Information Sun New Construction Window Installation Instructions

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Confort 26. Sliding Systems. Sapa Building System

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Lighter. Easier. Faster.

Guidelines for Earthquake Bracing of Residential Water Heaters

Squash Court Design general points

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

IMPORTANT INFORMATION

SikaProof A Technology

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Lightweight Partition Design for Residential and Commercial Buildings

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Installation Instructions and Ordering Information

PUBLIC RESTROOMS, DESIGN INTENT

Transcription:

Technical Data Sheet W13 Edition 2005-03 Knauf Fire Walls Knauf Fire Wall A2 - GKF two/ three layer cladding Knauf Fire Wall A1 - Fireboard two layer cladding The structural, statical properties, and characteristic building physics of Knauf systems can solely be ensured with the exclusive use of Knauf system components, or other products expressly recommended by Knauf.

Knauf Fire Walls Technical data / sound protection / thermal / fire protection Technical data / sound protection / thermal System Technical data dimensions wall stud cladding thickn. thickness type D h d Knauf Fire Wall A2 Fire protection System spacing of studs 31.25 cm 31.25 cm W132 Knauf Fire Wall A1 spacing of studs 31.25 cm 31.25 cm d h d D Fire rating Knauf Fire Wall A2 with Knauf Boards GKF W132 Knauf Fire Wall A1 with Fireboard 126 151 176 100 116 141 F90 F90 50 75 50 75 166 100 161 100 3 x 12.5 0.5 Cladding GKF metal sheet layer min. thickness mm Fire-resistant Boards 3 x 12.5 GKF A2 metal sheet 0.5 Solid Board Fire-resistant board GKF A2 metal sheet weight approx. kg/m² 20 12.5 Insulation without or mineral wool building material class A W13 2) 3) 3) R w,r sulation U value inmm db mm W/(m²K) Knauf Sound Protection Proof L 001-03.05 1) data of weight without 2) R w,r = calculation value of the sound reduction index of the separating partition acc. to DIN 4109 without longitudinal transmission via flanking components 3) Insulation layer acc. to DIN EN 13162; length related flow resistance acc. to DIN EN 29 053: r 5 kpa s/m² ; WLG: 040 spacing of studs 31.25 cm 31.25 cm spacing of studs 31.25 cm 31.25 cm d h d d h d D D mm mm mm single metal stud frame with GKF cladding 0.5 75 Solid 20 12,5 Board GKF 71 0,5 metal sheet layer single metal stud frame with Knauf Fireboard cladding 2x 15 0.5 type/ building material class Fireboard metal sheet layer 62 1) Sound protection 50 55 50 55 Proof ABP P-3073/0639 Fireboard A1 without Z-PA-III 2x 15 or 4.290 ABP mineral wool P-3074/0649 metal sheet 0.5 building material class A no 40 no 40 55 80 Thermal 1.65 0.57 0.49 0.39 no 40 60 80 1.79 no 0.58 40 0.50 60 0.40 80 1.39 no 0.33 80 2 Note Fire walls are fire-resistant walls that keep their stability and enclosing function under the influence of fire because they are especially resistant to dropping constructional components. (impact stress of 3000 Nm proofed after fire)

Knauf Fire Wall A2 Single metal stud frame: two layer cladding with Knauf Solid Boards 20 mm GKF 12.5 mm Wall heigths Stud Spacing of studs Maximum wall heights metal thickness 0.6 mm CW 50 cm 31.25 m 5 CW 75 31.25 7.5 CW 100 31.25 9 Details scale 1:5 Nailable Plug, a 100 cm CW stud galvanized metal sheet, 0.5 mm thick joint overlap 10 cm cladding horizontal -VO3 Connection to ceiling separation strip Trenn-Fix 65 Ceiling Steel Dowel, a 50 cm washer 30 mm t 2 mm connect to with blind metal rivets galvanized metal sheet 0.5 mm thick joint overlap 10 cm, cladding horizontal -A3 separation strip Trenn-Fix 65 Knauf Solid Board 20 mm Knauf Board GKF 12.5 mm Connection to solid wall Drywall Screw TN Knauf Solid Board 20 mm -VM3 Knauf Board GKF 12.5 mm -B3 Drywall Screw TN 3.5 x 35 Drywall Screw TN 3.5 x 45 Knauf Board GKF 12.5 mm Knauf Solid Board 20 mm connect CW stud to with blind metal rivets washer 30 mm t 2 mm Ceiling Steel Dowel, a 50 cm Drywall Screw TN 3.5 x 45, a = approx. 25 cm galvanized metal sheet Knauf Solid Board 20 mm Knauf Board GKF 12.5 mm -VU3 Connection to floor -D3 Corner 3

Knauf Fire Wall A2 Single metal stud frame: three layer cladding with Knauf Boards GKF 12.5 mm Wall heights Stud Spacing of studs Maximum wall heights metal thickness 0.6 mm CW 50 cm 31.25 m 5 CW 75 31.25 7.5 CW 100 31.25 9 Details scale 1:5 -VO1 Connection to ceiling separation strip Trenn-Fix 65 Ceiling Steel Dowel, a 50 cm washer 30 mm t 2 mm connect CW stud to with blind metal rivets -A1 Nailable Plug, a 100 cm galvanized metal sheet 0.5 mm thick joint overlap 10 cm separation strip Trenn-Fix 65 Knauf Boards GKF 3 x 12.5 mm Connection to solid wall Knauf Boards GKF 3 x 12.5 mm -VM1 Drywall Screw TN galvanized metal sheet 0.5 mm thick, joint overlap 10 cm, horizontal cladding -B1 Drywall Screw TN 3.5x55, washer 30 mm a = approx. 25 cm t 2 mm Knauf Ceiling Steel Dowel a 50 cm connect CW stud to with blind metal rivets Drywall Screw TN 4 -VU1 Connection to floor -D1 Corner

Knauf Fire Wall A1 Single metal stud frame: two layer cladding with Knauf Fireboard 15 mm Wall heights Stud Spacing of studs Maximum wall heights W132 metal thickness 0.6 mm cm m CW 100 31.25 9 Details scale 1:5 Nailable Plug, a 100 cm galvanized metal sheet 0.5 mm, joint overlap 10 cm W132-VO1 Connection to ceiling separation strip Trenn-Fix 65 Knauf Fireboard Filler 100x40x0.6 Knauf Ceiling Steel Dowel, a 50 cm connect CW stud 100x50x0.6 to with blind metal rivets W132-A1 Knauf Fireboard Filler Knauf Fireboard 2x 15 mm separation strip Trenn-Fix 65 Drywall Screws TN Connection to solid wall 100x50x0.6 Knauf Fireboard 2x 15 mm 100x50x0.6 Fiber Glass Tape Knauf Fireboard Filler W132-VM1 galvanized metal sheet 0.5 mm thick, joint overlap 10 cm, horizontal cladding W132-B1 Fiber Glass Tape 100x40x0.6 Knauf Fireboard Filler Knauf Fireboard 2x 15 mm Knauf Ceiling Steel Dowel, a 50 cm to with connect CW stud 100x50x0.6 blind metal rivets Drywall Screw TN 3.5x45, a = approx. 25 cm Knauf Fireboard Filler W132-VU1 Connection to floor W132-D1 Corner 5

Knauf Fire Walls Power sockets / settlement joints / deflection head Installation of power sockets W132 W13 12.5 15 approx. 100 x 100 approx. 100 x 100 12.5 15 mineral wool entire area power socket box made of Fire-Resistant Boards GKF mineral wool strip bxh 312x625 mm or mineral wool on entire area Fireboard Filler box made of Fireboard Fireboard Filler Note Power sockets, switch sockets, splitter sockets etc. are allowed to be installed at any position, but not opposite to each other. Entry of single electric cables is allowed. The remaining opening has to be closed with gypsum mortar. Details scale 1:5 a 20 mm 15-20 15-20 ca. 50 a 20 a 20 a Knauf Fugenfüller Leicht glued Knauf Board strips washer 30 mm 2 rows of heavy-duty dowels 10 mm, a 500 mm; installed alternating, installation according to approval For deflection heads do not rivet studs and runners, do not fix boards to. 20 20 20 20 20 20 Solid Board 20 mm Knauf Board GKF 12.5 mm 200 Solid Board 25 mm Knauf CW stud 50x50x0.6 galvanized metal sheet 0.5 mm thick, b 200 mm -VO4 Deflection head -BFU3 Settlement joint 20 20 20 20 20 20 20 additional metal sheet b = gypsum board strip additional metal sheet 50x50x0.6 20 20 20 20 20 50x40x0.6 fixed to ceiling and floor (once each) 100 resp. 75 -BFU1 75 resp. 50 Settlement joint 75 resp. 50 fixed to ceiling and floor (once each) Fireboard 25 mm Drywall Screw TN 3.5x35 W132-BFU2 Settlement joint 6 Note Door installation possible, according to appoval of door manufacturer: e.g. Schörghuber, Hörmann

Knauf Fire Walls Specifications W13 Item Description No. of units Unit price Total price... Fire Wall according to DIN 4102-3, non-load bearing, as drywall partition, height in m..., thickness 126 mm/ 151 mm/ 176 mm *, fi re resistance class according to DIN 4102-2, F 90, sound according to DIN 4109 R w,r in db 50/ 55 *, * thermal transmission coeffi cient according to DIN 4108-2, U value in W/ (m² K)... *, perimeter fi xed, cladding with three layers of Knauf boards GKF, 12.5 mm, with metal sheet layer 0.5 mm, with building material class A, thickness in mm... *. Product/ System: Knauf Fire Wall... m²......... Fire Wall according to DIN 4102-3, non-load bearing, as drywall partition, height in m..., thickness 116 mm/ 141 mm/ 166 mm *, fi re resistance class according to DIN 4102-2, F 90, sound according to DIN 4109 R w,r in db 50/ 55 *, * thermal transmission coeffi cient according to DIN 4108-2, U value in W/ (m² K)... *, perimeter fi xed, cladding with two layers of Knauf boards GKF, 20 mm 12.5 mm, with metal sheet layer 0.5 mm, with building material class A, thickness in mm... *. Product/ System: Knauf Fire Wall... m²......... Fire Wall according to DIN 4102-3, non-load bearing, as drywall partition, height in m..., thickness 161 mm, fi re resistance class according to DIN 4102-2, F 90, sound according to DIN 4109 R w,r in db 55, * thermal transmission coeffi cient according to DIN 4108-2, U value in W/ (m² K)... *, perimeter fi xed, cladding with two layers of Knauf Fireboard, 15 mm, with metal sheet layer 0.5 mm, with building material class A, thickness in mm... *. Product/ System: Knauf Fire Wall A1 W132... m²......... Connection to ceiling, sliding up to 20 mm, as upgrade to Knauf Fire Wall, installation according to drawing no....... m......... Corner, with corner trim *, as upgrade to Knauf Fire Wall, installation according to drawing no....... m......... Settlement joint as upgrade to Knauf Fire Wall, two/ three * layer cladding, width in mm..., installation according to drawing no....... m......... Settlement joint as upgrade to Knauf Fire Wall W132, width in mm..., installation according to drawing no....... m......... Wall opening for power sockets, as upgrade to Knauf Fire Wall, dimensions in mm..., installation according to drawing no....... pcs......... Door opening with lintel, enforced fl oor to ceiling, with metal studs UA 50/ 75/ 100 *, incl. connections to fl oors and ceilings, fi x with angels, dowels and screws. basic dimensions B/H in mm..., wall thickness in mm..., installation according to drawing no........ pcs...... * Cancel not applicable items Sub-total... 7

Knauf Fire Walls Construction and application, surface treatment W13 Construction Knauf Fire Walls consist of a single metal stud frame. Two or three layers of Knauf boards are screwed to both sides of the metal framework. A metal sheet is installed below the top layer of the cladding. Insulation material according to the requirements of building physics can be installed in the partitions cavity. Settlement joints have to be taken over into the construction of the Fire Walls. For continuous walls use control joints at approx. 15 m. Application Metal stud frame Apply (two strings) or Sealing Tape to backside of runners for the connection of fl anking constructional components. For sound protection requirements seal up carefully with acoustical sealant according to DIN 4109, supplement 1, chapter 5.2; porous sealant strips like Sealing Tape are usually not suitable in this case. Fix perimeter runners (s at fl oor and ceiling, CW studs at walls) with suitable dowels to fl anking components, e.g. Ceiling Steel Dowel with reinforced concrete ceilings (use and application according to Construction Supervisory Permit Z-21.1-1519) and nailable plug with masonry. Spacing of dowels 0.5 m at ceilings, 1 m at walls (at least 3 fi xing points). For use dowel with washer Ø 30 mm, t 2 mm for connections to ceiling and fl oor. Install CW studs at a spacing of 31.25 cm in s, aligne, fi x with two metal rivets ( 3 x 8 mm) each to bottom and top. Cladding Two layer cladding of with horizontally applied Knauf Solid Board 20 mm vertically applied Knauf board GKF 12.5 mm or with three layer cladding with vertically applied Knauf boards GKF 12.5 mm. Two layer cladding of W132 with horizontally applied Knauf Fireboard 15 mm. Spacing of screws of fi rst layer 75 cm, of middle layer 50 cm and of top layer 25 cm. Displacement of joints according to DIN 18181. Metal sheets as plates or coil material, 0.5 mm thick, install horizontally under top layer, overlap all joints at least 10 cm. Screwing with Drywall screws ( three layers: TN 3.5 x 45/ two layers and W132: TN 3.5 x 35) only to fi x for installation, remove while applying the boards. Vertical joints of metal sheets only on studs. ing Filling and covering of joints should only take place after the boards have been allowed to rest in the given humidity and temperature zones, and no more longitudinal changes can be expected, i.e. expansion or contraction. s should be filled at a minimum temperature of 10 C. In case of mastic asphalt screed, fill in joints after screed has been applied. Cover all screw heads as well. For double layer cladding, fill in joints of first layer, smooth joints of second layer. : Fill in joints with without using tape. If using tape, fill in with Knauf Fugenfüller Leicht or with Ames machine and Knauf filler-super. Recommendation: Fill in and tape cut edges of visible layers no matter which filling material is used. W132: Hand filling with Fiber Glas Tape and Knauf Fireboard Filler. Fixing of Knauf boards with Drywall Screws TN and TB cladding fixing of Knauf boards to metal studs (minimum penetration 10 mm) thickness in mm metal thickness 0.7 mm 0.7 mm < s 2.25 mm 2 x 15 Fireboard TN 3.5 x 25 TN 3.5 x 45 TB 3.5 x 35 TB 3.5 x 45 20 12.5 GKF TN 3.5 x 35 TN 3.5 x 45 TB 3.5 x 35 TB 3.5 x 45 3 x 12.5 GKF TN 3.5 x 25 TN 3.5 x 35 TN 3.5 x 55 TB 3.5 x 25 TB 3.5 x 45 TB 3.5 x 55 Surface treatment Use a primer on Knauf Boards before coating or painting them. Ensure that the primer and the coat or paint are compatible. After wallpapering of paper and fi ber glass wallpapers and the application of resin / cellulose plasters quick drying must be assured through adequate airing. The following coats can be used to cover Knauf Boards: Plasters: Knauf structured plasters, e.g. resin plasters, thin plasters, entire area smoothing like e.g. Knauf Board-Finish, mineral plasters in connection with paper taped jointing. ceramic tiles Wall Papers: paper-, textile and synthetic wall papers. Use only adhesives made of cellulose according to Merkblatt Nr. 16, Technische Richtlinien für Tapezier- und Klebearbeiten, Frankfurt/Main 2002, released by Bundesausschuss Farbe und Sachwertschutz. Coats: Washable and abrasion-proof emulsion paint, multicolored (rainbow) emulsion, oil paint, matte-fi nish lacquer, alkyd resin paint, polymer resin paint, PUR lacquer, or epoxybased lacquer, according to intended use or as required. Alkaline coats such as lime, water glass colors and silicate-based paints are unsuitable for gypsum board surfaces. Silicate-based emulsion paints may be used after referring to the manufacturer s recommendations and following the stipulated guidelines closely. Gypsum board surfaces that have constantly been exposed to light without any protection can develop yellowing agents that show up despite a coat of paint. Therefore a trial coat is recommended that will extend across several boards including all joints. Yellowing can, however, be successfully avoided only by using a special shielding primer. Knauf Direkt Technical Information Service: Phone 49 18 05 / 31-10 00, Fax 49 18 05 / 31-40 00 Knauf websites: www.knauf.de, www.knauf.com e-mail: knauf-direkt@knauf.de Knauf Headquarters, Am Bahnhof 7, D-97346 Iphofen, Phone 49 93 23 / 31-0, Facsimile 49 93 23 / 31-277 8 All technical changes reserved. Only the current printed instructions are valid. Our warranty is expressly limited to our products in flawless condition. All application quantities and delivery amounts are based on empirical data that is not easily transferable to other deviating areas. All rights reserved. All amendments, reprints and photocopies, including those of excerpts, require the express permission of Knauf Gips KG, Am Bahnhof 7, 97346 Iphofen, Germany. Edition: March 2005 W13 / engl. / D / 03.05 / FB / D