This section applies to the design and installation of transformers.



Similar documents
SECTION SUBSTATION TRANSFORMERS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

Primary and Secondary Electrical Distribution Systems

Multi-tap Transformers

Secondary Unit Substations

Sample - No Commercial Use

Unified requirements for systems with voltages above 1 kv up to 15 kv

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

SECTION HEAT PUMPS

Diesel Engine Driven Generators Page 1 of 6

SWITCHGEAR Section 16. SECTION INCLUDES This Section includes service and distribution switchboards rated 600 V and less.

600 Volt Class Transformers

Unit substation solutions with type SIMOSEC primary switches quick reference guide E50001-F710-A389-X-4A00. Answers for energy.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Hyperlinks are Inactive

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

Receiving, Installing, Operating and Maintaining Dry Type, VPI Sealed, Cast Coil and UNICLAD Transformers

Low Voltage Transformers Sealed, General Purpose, Dry Type

SECTION MEDIUM VOLTAGE SWITCHGEAR

TRANSFORMER DICTIONARY

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Table of Contents. TransformerIQ FAQs 1

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) J. Instruction Leaflet

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Distribution Dry Type Transformers

SECTION ELECTRICAL ACCEPTANCE TESTS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

16300 MEDIUM VOLTAGE DISTRIBUTION

Engineers Edge, LLC PDH & Professional Training

Unit Substation Transformers

Single Phase Three Phase Single Phase Export Model Transformers Single Phase Buck and Boost Transformers Stainless Steel Enclosed Transformers

Distribution Dry Type Transformers

Power Plant Electrical Distribution Systems

SECTION DRY-TYPE TRANSFORMERS

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Some important Indian Standards related to Transformer are as follows:

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Electrical. This section applies to the design and installation of building power distribution systems.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

S. C. Electric Cooperative s Specification for a Three-Phase, Padmounted URD Transformer (Revised 12/2014)

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Project Name: Nortrax Section Project No: SURGE PROTECTION DEVICES Page 1

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT NETWORK SYSTEMS SECTION

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

CalMod Design-Build Electrification Services

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Kuhlman Electric Corporation Volt Instrument Transformers

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Medium Voltage Electrical Distribution

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Primary Electric Distribution for Industrial Plants

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Presentation of the France Transfo factories

The Intelligent AX1 Switchgear for Medium Voltage

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

Water Leak Detection System

Instructions for Secondary Unit Substation Transformers KVA, Three Phase

Atlanta Chapter IEEE Industry Applications Society

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

INTERNATIONAL STANDARD

E2 Series Electric Furnaces

SECTION 16346A METAL-CLAD MEDIUM VOLTAGE ARC RESISTANT SWITCHGEAR

Mini Power-Zone Unit Substation

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

COMPARISON OF ANSI/IEEE AND IEC REQUIREMENTS FOR LOW- VOLTAGE SWITCHGEAR

Transformer Design & Design Parameters

Annex-A TECHNICAL SPECIFICATION

Issued E.C.S. Section WTR00 INFORMATION SECTION Page 1 of 1

Generator DoCKInG StatIonS

Data Center Solutions. Envirotran HDC Transformers Deliver Superior Reliability and Efficiency for Substantial Savings Everyday

2013 RESIBLOC transformers Product presentation. ABB Group October 2, 2013 Slide 1

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

SECTION MORTUARY REFRIGERATORS

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

A. Shop Drawing submittals shall include, but not be limited to, the following:

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Transformer Questions & Answers

Modular Systems wind portfolio overview Power Collection and Grid Connection products

MEDIUM VOLTAGE DISTRIBUTION

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Switchgear Capabilities. NexGear is a Division of PowerSecure NASDAQ: POWR

MCR1900 Media Converter 19-Slot Chassis

Magnum Mobile Generator MMG55 Specifications

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

ACME ELECTRIC CORPORATION PDPD-01

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Transcription:

ELECTRICAL: TRANSFORMERS BASIS OF DESIGN This section applies to the design and installation of transformers. Design Criteria 13.8-kV equipment shall be 15-kV class. Coordinate with short-circuit studies for design fault duties. Determine the required through fault rating of the transformer. Specify isolating type with grounded electrostatic shield when serving computer systems. Specify K-rated type when serving loads characterized with high harmonic currents. UC requires a minimum 4K rating. Specify ultra-quiet type when installed near offices and classrooms. Noise level shall not exceed 35 db up to 300 KVA and shall be factory certified. Design Evaluation The following information is required to evaluate the design: Schematic Design Phase Quantity and rating of transformers based on preliminary load calculations Outline specifications Design Development Phase One-line diagram showing quantity and rating of transformers Preliminary plans showing location of transformers Draft specifications Construction Documents Phase Completed one-line diagram showing quantity and rating of transformers Completed plans showing location of transformers including installation footprint, connection, seismic support details, and housekeeping pads Complete specifications Submittals Current manufacturer s Association of Edison Illuminating Companies (AEIC) prequalification data DESIGN GUIDELINES AND STANDARDS T 1

Shop drawings including: Complete description of products to be supplied, product data, dimensions, specifications, connection diagrams, and installation instructions Detailed selection data for vibration isolator supporting equipment, equipment identification mark, isolator type, and actual load Products, Materials, and Equipment Unless otherwise specified, transformers shall meet the sound levels of the National Electrical Manufacturers Association (NEMA), the American National Standards Institute (ANSI), and/or the Institute of Electrical and Electronics Engineers (IEEE), whichever is most conservative. Supply certified tests upon request of University of Cincinnati Construction Management (CM). Note: The above requirement may necessitate architectural solutions. Dry-Type Transformers Transformers shall be of fire-resistant, air-insulated, dry-type construction, cooled by the circulation of air through the windings. Transformers shall be 150 degree C; class H, 220-degree insulation, indoor-ventilated dry type, vacuum pressure impregnated (VPI). The entire core and coil assembly shall be VPI with a high-temperature thermo setting polyester varnish. The total VPI process shall apply a one-cycle shield of resin to the coils and bus, core, and support structure. The VPI process shall effectively encapsulate the entire core and coil assembly, resulting in a transformer that is virtually impermeable by moisture, dust, dirt, salt air, and other industrial contaminants. The electrical insulation system shall utilize Class H material in a fully rated 220-degree C system. Base transformer design temperature rate of rise shall be on a 30-degree C average ambient over a 24-hour period with a maximum of 40 degrees C. Solid insulation in the transformer shall consist of inorganic materials such as porcelain, glass fiber, and electrical-grade glass polyester on Nomex. All insulating materials must be rated for continuous 220 degree C duty. The insulation between the high and low voltage coils shall be more than sufficient for the voltage stress without need for a varnish. Transformers shall be of the highest quality, manufactured by a firm that has manufactured such apparatus for at least 25 years. Transformers shall have minimum 98 percent efficiency. DESIGN GUIDELINES AND STANDARDS T 2

Transformers will have high-voltage (primary) terminal markings: 1. H1" to "A" Phase 2. "H2" to "C" Phase 3. "H3" to "B" Phase Low-voltage switchgear normally connected to building power service transformers will be constructed in accordance with industry standards. Buses will be identified "1," "2," "3," and "N." Transformers will have low-voltage (secondary) terminal markings "X1," "X2," "X3," and "X0" from left to right or top to bottom when facing the low-voltage terminals. The switchgear shall be as follows: 1. "X1" to "1" (BUS) 2. "X2" to "2" (BUS) 3. "X3" to "3" (BUS) Note: The transformer connections as indicated above will result in a rotation sequence at the low voltage switchgear of "1," "2," "3". All transformers shall be provided with American Standard connection, 30-degree negative angular displacement. Transformer impedance should be about 5.75 percent (7 percent for three-transformer networks). For two-transformer networks, special transformer impedance must be determined so that voltage regulation issues are resolved. Confer with Construction Management for these applications. Transformers shall be provided with the following: Diagrammatic nameplate listing all detailed information as required by NEMA standards. Four 2½ percent, full-capacity taps, two above and two below rated voltage. Lifting lugs. Base suitable for skidding in all directions. Transformer case shall be supplied in a knockdown design. Windings, which shall be copper. A fully insulated secondary neutral bushing (externally groundable) to permit the use of a neutral conductor or current transformer or sensing of ground fault currents. Terminal markings on the transformer terminals. These markings shall clearly identify each terminal when doors or covers are opened. DESIGN GUIDELINES AND STANDARDS T 3

Electrical connections between the transformer and the switchgear (these shall be provided by the switchgear manufacturer). Air-filled primary terminal chamber adequately sized for stress cone termination of three or six single conductors, as indicated. For transformers serving the "normal" loads: Automatic temperature-controlled fans. These forced-air (FA) units shall contain all necessary components and wiring, including fans, for increasing the KVA ratings by 33 percent at 150 degrees C. The FA package shall include an electronic temperature monitor and fan control unit with the following features: Digital readout: Green = power on; yellow = fan on; red = high-temperature indicating lights Audible high-temperature alarm with alarm silence pushbutton Maximum temperature memory with read and reset switch Auto/manual fan control switch System test switch Temperature sensing in all three low voltage coils Auxiliary alarm contact and means for remote control and temperature monitoring shall be provided. Control power shall be provided from a control power transformer in the secondary switchgear. For emergency unit substation transformers: pre-wiring for future fan cooling, including resistance temperature detector (RTD) or thermocouples embedded in the windings for temperature control (same as FA package described above, but without fans). Continuous ¼-inch by 2-inch ground bus for connection to the adjacent compartment's switchgear. Transformers shall be designed to meet the sound level standards for dry-type transformers as defined in NEMA TR1. The following factory tests shall be made on all transformers, although not necessarily in the order listed. All tests shall be in accordance with the latest revision of ANSI Test Code C57.12.91 and NEMA TR1, IEEE 262A-1974: Resistance measurements of all windings on the rated voltage connection of each unit and at the tap extremes of one unit only of a given rating on this indoor or outdoor installation. Ratio tests on the rated voltage connection and on all tap connections. Polarity and phase-relation tests on the rated voltage connections. No-load loss at rated voltage on the rated voltage connection. DESIGN GUIDELINES AND STANDARDS T 4

Exciting current at rated voltage on the rated voltage connection. Impedance and load loss at rated current on the rated voltage connection of each unit and on the tap extremes of one unit only of a given rating on this project. Temperature test(s), to be made on one unit only of a project covering one or more units of a given KVA rating. Tests shall not be required when there is an available record of a temperature test on an essentially duplicate unit. When a transformer is supplied with auxiliary cooling equipment to provide more than one KVA rating, temperature tests as listed above shall be made on the lowest KVA AA rating [and the highest KVA FA rating]. Applied potential test. Induced potential tests. Transformers shall include a steel panel enclosure with louvered openings to guard against insertion of foreign objects. Ventilated dry-type transformers shall comply with ANSI C57.12.51. Liquid-Filled Transformers The following requirements shall apply to liquid-filled transformers: Liquid-filled transformers shall be for outdoor use only. Liquid-filled padmount transformers shall comply with ANSI C57.12.27. Only dead-front design shall be used. Transformers may be integral with primary switching, fusing, and separable connection compartment. Connections shall be via bushing wells for Elastimold or Colt Industries removable studs. Removable bushings shall be included. Load break parking stands shall be included. Protection shall be via bayonet fuse. No isolation links are allowed. Vibration Isolation Mounting type, unit DNP (double neoprene pad): Neoprene pad isolators shall be formed by two layers of ¼-inch to 5 /16-inch-thick ribbed or waffled neoprene, separated by a stainless steel or aluminum plate. These layers shall be permanently adhered together. Neoprene shall be 40 to 50 durometer. The pads shall be sized so that they will be loaded within the manufacturer's recommended range. DESIGN GUIDELINES AND STANDARDS T 5

A steel top plate equal to the size of the pad shall be provided to transfer the weight of the supported unit to the pads. Installation, Fabrication, and Construction Units shall be anchored to their pads as required to meet seismic zone requirements. Initially connect transformers at normal tap. After the facility is completely energized, measure the primary and secondary voltages at all transformers and the service switchboard. Forward a list to the Engineer for evaluation. Reconnect and adjust taps as directed. All costs associated with this work are to be included in the base bid. END DESIGN GUIDELINES AND STANDARDS T 6