VoIP Ceiling Speaker with Allworx 6x Server Setup Guide



Similar documents
VoIP Intercom with Allworx 6x Server Setup Guide

3COM VCX PBX Server VoIP Intercom Setup Guide

VoIP Intercom and Cisco Call Manager Server Setup Guide

Elastix Server VoIP Intercom Setup Guide

VoIP Intercom and Elastix Server

Configuring CyberData VoIP Ceiling Speakers

CyberData VoIP V2 Speaker with VoIP Clock Kit Configuration Guide for OmniPCX Enterprise

Configuring the Cisco SPA9000 Voice System with the Cyberdata VoIP Intercom for Door Bell Applications

NEC Univerge PBX VoIP Intercom Setup Guide

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Allworx 6x IP PBX

Applies to: F1PG200ENau Belkin Analogue Telephone Adapter (ATA) Firmware release notes

Configuring the CyberData VoIP 4-Port Zone Controller with Audio Out

Snom 720 and Elastix Server

Configuring CyberData Devices for Intermedia Hosted PBX

V2 Paging Amplifier PingTone Server Setup Guide

RingCentral Office. Configure Grandstream phones with RingCentral. To contact RingCentral, please visit or call

Cisco Linksys SPA 2102

VoIP Zone Controller: 4-Port Audio Out Operations Guide

RingCentral Office. Configure Aastra phones with RingCentral

Sipura SPA-3102 Simplified Users Guide Version 1.1a In Progress :)

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

FLX VoIP Registering with Avaya IP Office 500

DLink-655 Router Configuration Guide for VoIP

Allo PRI Gateway and Elastix Server

Configuring an IP (SIP) Polycom Soundstation on the Avaya IP Office

IP Session/Cyberdata IP Endpoints. IP Paging and Access Control

P-3202H-Bb. G-PON VoIP IAD DEFAULT LOGIN DETAILS. Firmware v1.0 Edition 1, 09/2009. IP Address: Password: 1234

3rd Party VoIP Phone Setup Guide (Panasonic b)

Configuring Avaya 1120E, 1140E, 1220 and 1230 IP Deskphones with Avaya IP Office Release 6.1 Issue 1.0

Optimum Business SIP Trunk Set-up Guide

NF1Adv VOIP Setup Guide (for Generic VoIP Setup)

GSatTrack. Fleet Broadband Tracker. User Manual April 2011 GSE. Global Satellite Engineering. : gsat.us

SETTING UP REMOTE ACCESS ON EYEMAX PC BASED DVR.

AudioCodes. MP-20x Telephone Adapter. Frequently Asked Questions (FAQs)

InSciTek Microsystems 635 Cross Keys Park Fairport, NY Setting up Your Phones

1. Installation Requirements

SINGLE NUMBER SERVICE - MY SERVICES MANAGEMENT

DVG-2101SP VoIP Telephone Adapter

Broadband Phone Gateway BPG510 Technical Users Guide

2100 Series VoIP Phone

Installation Guide. Before We Begin: Please verify your practice management system is compatible with Dental Collect Enterprise.

IMPORTANT NOTICE CONCERNING EMERGENCY 911 SERVICES

Vdex-40: Zoiper Quick Setup

SwyxWare VoIP Zone Controller, 4-Port Audio Out Setup Guide

Configuring the CyberData VoIP Intercom for eon's econn IP-PBX

SIP-T22P User s Guide

NF1Adv VOIP Setup Guide (for Pennytel)

Motorola TEAM WS M Configuring Asterisk PBX Integration

Release Notes for NeoGate TA410/TA X

How do I Install and Configure MS Remote Desktop for the Haas Terminal Server on my Mac?

1 VoIP/PBX Axxess Server

IIS, FTP Server and Windows

Hardware Overview. Ooma Linx devices These are installed around the office and are used to connect phones and other devices to your Ooma Office system

3rd Party VoIP Phone Setup Guide (Panasonic UT )

CyberData SIP Paging Adapter Integration with Zultys MX

NF3ADV VoIP Setup Guide (for TPG)

Configuring Positron s V114 as a VoIP gateway for a 3cx system

Configuring the Synapse SB67070 SIP Gateway from AT&T for Clearfly SIP Trunking. January 2013

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

Chapter 1 Installing the Gateway

How do I Install and Configure MS Remote Desktop for the Haas Terminal Server on my Mac?

Opera Wireless Mobilty

ZyXEL IP PBX Support Note. ZyXEL IP PBX (X2002) VoIP. Support Notes

Fonality. Optimum Business Trunking and the Fonality Trixbox Pro IP PBX Standard Edition V p13 Configuration Guide

Switches recommended for use with RingCentral VoIP services

For additional information, refer to the user guide of Yealink VP530 IP video phone or contact Yealink FAE (Field Application Engineer).

IMPORTANT NOTICE CONCERNING EMERGENCY 911 SERVICES

Scan to Quick Setup Guide

Configuring Windows for TAPI

Using Advanced Phone Features

DINSTAR DAG1000-4S4O with Elastix Setup Guide

Personalizing Your Individual Phone Line Setup For assistance, please call ext. 102.

P160S SIP Phone Quick User Guide

IP-PBX Quick Start Guide

How to setup Mobility Extension on the 2N OfficeRoute and 2N VoiceBlue Enterprise

Quick Installation Guide. Live! Titanium

All Rights Reserved. Copyright 2007

How to configure Linksys SPA for VOIP Connections

For additional information, refer to the user guide of Yealink SIP-T2xP IP phones or contact Yealink FAE (Field Application Engineer).

Application Note. IP8000 Conference Phone Configuration Guide. Table of Contents. Overview. Requirements. ST October 25, 2007

Digium Switchvox AA65 PBX Configuration

Hands-on MESH Network Exercise Workbook

WEB CONFIGURATION. Configuring and monitoring your VIP-101T from web browser. PLANET VIP-101T Web Configuration Guide

How To Configure A Linksys Pap2T With Virtualbpx On A Cell Phone On A Pc Or Ipad Or Ipa (For Ipa) On A Ipa Or Ip2T On A Sim Sim (For Sim Sims

Procedure to Upgrade VIP-350PT/550PT by Web Browser

iinet ATA Telephone Adapter

Configuration Notes 283

Linksys Gateway SPA2100-SU Manual

Configuration Notes 290

RIU-IP Remote IP Interface User Guide

Click on the PBX icon on the Admin screen to start building your PBX. The Phones page shows all the Phone Accounts and Hunt Groups you have created.

CPEi 800/825 Series. User Manual. * Please see the Introduction Section

Version 0.1 June Xerox WorkCentre 7120 Fax over Internet Protocol (FoIP)

How To Test Your Network For A Better Speed On 3Ngnetworks.Com

SL 1100 Quick Start Help Guide Table of Contents:

Phaser 3635MFP Software Upgrade Process

Hosted VoIP Outlook TAPI Integration

OBiTALK Portal Device Management

Configuring the CyberData V2 Paging Amplifier for eon's econn IP-PBX

SCADA Security. Enabling Integrated Windows Authentication For CitectSCADA Web Client. Applies To: CitectSCADA 6.xx and 7.xx VijeoCitect 6.xx and 7.

Transcription:

VoIP Ceiling Speaker with Allworx 6x Server Setup Guide CyberData Corporation 2555 Garden Road Monterey, CA 93940 T:831-373-2601 F: 831-373-4193 www.cyberdata.net

2 1.0 Setup Diagram Figure 1-1 is a setup diagram for a single VoIP speaker configuration. In this configuration, the ceiling speaker acts as a standalone SIP telephony device. Figure 1-1. Setup Diagram Allworx 9112 IP Phone 192.168.2.xx Allworx 6x System 192.168.2.254 (default) CyberData VoIP Ceiling Speaker 192.168.2.xx Linksys EtherFast 10/100 8-port Workgroup Hub

3 2.0 Host PC Environment Table 2-1. Host PC Environment Details Description Hardware Type Allworx 6x Hardware Version Configuration 04 Software Type Software Version 6.8.3.1 3.0 Test Setup Equipment Table 3-1. Test Setup Equipment Equipment Model Version Allworx VoIP Phone 9112 1.8.2.1 Allworx System 6x 6.8.3.1 CyberData VoIP Ceiling Speaker 010844D 4.01 Linksys EtherFast 10/100 8-port Workgroup Hub EFAH08W 2.0

4 4.0 Setup Procedure To set up the Allworx 6x SIP Server for the CyberData VoIP Ceiling Speaker, 1. Go to the Login page. By default, the login can be found at the following web address: 192.168.2.254:8080 2. On the Login page, enter the password and click on Login to go to the Home page. The default password is admin. Figure 4-2. Login Password Login

5 3. On the Home page, go to the PHONE SYSTEM section and click on Handsets to go to the Handsets page. Figure 4-3. Home Page Handsets

6 4. On the Handsets page, go to the SIP Handsets section and click on Add new SIP Handsets to go to the Add new SIP Handsets page. Figure 4-4. Handset Page add new SIP Handset

7 5. On the Add SIP Handsets page, enter the following information as shown in Figure 4-5: Caller ID Name Description Model Number of Lines Login ID Password Note The information that you enter must match the SIP information in the Ceiling Speaker. In Figure 4-5, the speaker is set for extension 5103. Figure 4-5. SIP Handset Add Password Add Login ID Model Number of Lines Description Caller ID Name

8 Note Figure 4-6 is an example of a CyberData VoIP Ceiling Speaker that is configured to extension 5103. Figure 4-6. Ceiling Speaker Configured to Extension 5103 6. Click Add to go back to the SIP Handsets page.

9 7. Upon returning to the SIP Handsets page, you will see (never registered) in the Identification column of the Generic SIP section. Figure 4-7. SIP Handset Never Registered (never registered) in the Identification column 8. To register the speaker, you will need to reboot the speaker by logging into the CyberData Configuration Home page.

10 9. Log into the CyberData Configuration Home page (Figure 4-8) by pointing your browser to the speaker s IP address. For the initial configuration of the speaker, refer to the VoIP Ceiling Speaker Operation Guide which can be found at the following web address: http://www.cyberdata.net/support/voip/ceilingspeaker.html Note You may also download CyberData s VoIP Discovery Utility program which allows you to easily find and configure the default web address of the CyberData VoIP products. CyberData s VoIP Discovery Utility program is available at the following web address: http://www.cyberdata.net/support/voip/discovery_utility.html 10. When prompted, enter the following Web Access Username and Web Access Password to access the CyberData Configuration Home page (Figure 4-8): Default Login: Web Access Username: admin Web Access Password: admin Figure 4-8. CyberData Configuration Home Page 000000 11. Click Upgrade Firmware to open the Firmware Upgrade page. Upgrade Firmware

11 12. On the Upgrade Firmware page, click on Reboot. Figure 4-9. Reboot VoIP Speaker Reboot

12 13. After clicking on Reboot, a reboot timer countdown will begin. Figure 4-10. Speaker Reboot Timer 14. After the speaker reboots, the green Status LED on the speaker will blink at one second intervals to indicate normal operation. Note If Yes is selected for Speaker Beep After Initialization on the Speaker Setup page, you will hear a tone after the initialization sequence is complete.

13 15. Refresh the SIP Handsets web page and verify that the speaker is registered. The Identification column of the Generic SIP row shows the address and port that the speaker is using. Figure 4-11. Successfully Registered Speaker Address and Port Number 16. To test the speaker, pick up any phone that is configured to the Allworx system and call the speaker s extension number. 17. When a connection is established (as indicated by a beep), speak into the phone and verify that you can hear your voice through the speaker.

14 CyberData Corporation 930249A Server Setup Guide