CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: GM32 ln-situ-gasanalysator model Cross Duct for NO and S02

Certificate: / 29 April 2014

Certificate: / 9 September 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. about Product Conformity (QAL 1) Number of Certificate: _01. TÜV Rheinland Energie und Umwelt GmbH

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: NIS Ingenieurgesellschaft mbh lndustriestr Alzenau Germany

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: DURAG data systems GmbH Kollaustr Harnburg Germany

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: Gaschromategraph GC 5000 BTX Type FID for Benzene

TÜV RHEINLAND ENERGIE UND UMWELT GMBH

Guido Baum Phone: +49(0) Mail:

EN Type Approval & Certification of AMS (QAL1)

S300 Series Dust Monitors

Performance Standards and Test Procedures for Continuous Emission Monitoring Systems

Performance Standards and Test Procedures for Automated Dust Arrestment-Plant Monitors

1.0 What Are the Purpose and Applicability of Performance Specification 11?

DUST EMISSION MONITORING SYSTEM

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

How To Use A Ds340 (Dsp)

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Automation and Systems Technology. LABCONTROL TFM/TPM User Manual TroxMConnect Operating Software. 1. Introduction Software Installation 2

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

Material test chamber with mechanical convection

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

Product Information Sheet UH28CS-12kV Hi Pot Tester

Application Note 12: TrendView Recorders Continuous Emissions Monitoring

Digital inductive conductivity transmitter

Analytical Service Certification Program

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN.

Flue Gas Analysis as a Diagnostic Tool for Fired Process Heater Furnaces

JUMO tecline HD ph and JUMO tecline HD Rd

FMT600BT Transmitter

Emission Monitoring and Reporting (EMR) Guidelines for Continuous Emissions Measurements in Holcim Cement Plants

Conversion Between Analog and Digital Signals

Half the cost Half the carbon

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Highly efficient flue gas analyzer

CALIBRATION PRINCIPLES

CONFIGURABLE SAFETY RELAYS

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Degree programme in Automation Engineering

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

6888Xi Advanced Electronics for Zirconium Oxide Flue Gas O 2 Probes. Instruction Manual Xi December 2012

Expert Report. History of the development of water level control in steam- and hot water boilers

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

KNX Gateway RGK E-01

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

J TB/TW Temperature limiter, temperature monitor

Current Loop Application Note 1495

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Inventory Control. Inventory Control Tank & Silo Weighing

T7560A,B,C Digital Wall Module

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS

EN A new unified testing and approval scheme for automated measuring systems

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Application Requirement

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Analysis instrumentation EI&C engineering and automation Technical diagnostics. Services FROM THE professionals

GREISINGER electronic GmbH

PRODUCT CONFORMITY CERTIFICATE

Online Infrared Flue Gas Analyzer Gasboard 3000

TÜV RHEINLAND IMMISSIONSSCHUTZ UND ENERGIESYSTEME GMBH

How To Use A Flowmeter

M20. Technical Guidance Note (Monitoring) Quality assurance of continuous emission monitoring systems - application of EN and BS EN

EBS852 (Contrac) Power Electronic Unit

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

S4000TH HART. HART Communication Manual

CONFIGURABLE SAFETY RELAYS

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

NX Series Inverters. HVAC Pocket Programming Guide

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Cooling Channel Optimization

PREMIUM CLEAN ROOM MONITOR MODELS 8630-CRM-S 8630-CRM-P

Process Alarm Solutions

Heating Controller. Building Technologies HVAC Products

Transcription:

Test report: 936/21219899/C of 30 August 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 01 April 2014 B12, chapter II, No. 1.1 Approved application The tested AMS is suitable for use at combustion plants according to Directive 2010/75/EU, chapter III, at waste incineration plants according to Directive 2010/75/EU, chapter IV and other plants requiring official approval. The tested ranges have been chosen with respect to the wide application range of the AMS. The suitability of the AMS for this application was assessed on the basis of a laboratory test and an eleven-month field test at a municipal waste incinerator. The AMS is approved for an ambient temperature range of -20 C to +50 C. Any potential user should ensure, in consultation with the manufacturer, that this AMS is suitable for the installation at which it will be installed. Basis of the certification This certification is based on: test report 936/21219899/C of 30 August 2013 of TÜV Rheinland Energie und Umwelt GmbH suitability announced by the German Federal Environment Agency (UBA) as the relevant body the ongoing surveillance of the product and the manufacturing process publication in the German Federal Gazette (BAnz AT 01 April 2014 B12, chapter II, No. 1.1, Announcement by UBA from 27 February 2014) qal1.de info@qal1.de page 2 of 6

AMS designation: Model 6888A for O 2 Manufacturer: Emerson Process Management Rosemount Analytical Inc, Solon, USA Field of application: For measurements at plants requiring official approval (Directive 2010/75/EU on industrial emissions, chapter III and IV) Measuring range during the performance test: Component Certification range Unit O 2 0-25 Vol.-% Software version: V 1.048 Restrictions: None Notes: 1. The maintenance interval is four months. 2. The AMS is available in two configurations: Model 6888A-1OXY-4-1-5DR (the raw signal is processed by the external control unit 6888Xi) and Model 6888A-1OXY-4-1-1HT (the raw signal is processed directly at the probe head). 3. Supplementary testing (extension of the maintenance interval) as regards Federal Environmental Agency notice of 03 July 2013 (BAnz AT 23 July 2013 B4, chapter II No. 1.1). Test report: TÜV Rheinland Energie und Umwelt GmbH, Cologne Report No.: 936/21219899/C of 30 August 2013 qal1.de info@qal1.de page 3 of 6

Certified product This certificate applies to automated measurement systems conforming to the following description: The measuring system model 6888A is a zirconium dioxide probe for the measurement of oxygen with a measurement range of 0 25 Vol.-%. The continuously heated sensor is fitted to the tip of the probe so that it is exposed to the flue gas in its in-situ position. It generates a millivolt signal between the measuring and the reference electrodes. This current is caused by a potential difference which is a result of different oxygen particle pressures. The measuring electrode is exposed to the flue or exhaust gas, while the reference electrode is surrounded by span gas (usually ambient or instrument air with 20.95 Vol.-% O 2 ). Due to its direct position in the exhaust gas, the ZrO 2 measuring cell measures the oxygen concentration as a percentage of the overall volume, including the steam concentration. The measuring system model 6888A comprises a measuring probe with probe head as well as Xii electronics. The measuring system is available in two configurations: model 6888A-1OXY-4-1-5DR; and model 6888A-1OXY-4-1-1HT. There are no processing electronics in the probe head in variant 6888A-1OXY-4-1-5DR. The raw signals from the measuring cell are transmitted via a 7-core special cable from the probe housing to the Xi electronics, where they are then processed. Furthermore, the Xi electronics provide the heating element of the probe with electricity and regulates the temperature of the ZrO 2 measuring cell. In variant 6888A-1OXY-4-1-1HT the signal-processing electronics and the electricity supply are located directly in the probe head on the probe. The raw signal is transformed into a linear 4-20 ma analogue signal in the probe housing and the temperature of the probe heating is regulated. Both system variants are controlled by Xi electronics. In the case of variant 6888A-1OXY-4-1-5DR the electronics are fitted with a circuit board for signal processing and temperature control. This circuit board is not present in variant 6888A-1OXY-4-1-1HT which has probe-internal processing electronics. Regardless of the variant, the probes are available in various configurations. Probes are available in lengths between 0.457 m and 5.49 m. Probes of 0.91 m length were used in the perfomance test. A filter is fitted on the probe head before the ZrO 2 measuring cell. Depending on the temperature of the exhaust gas to be measured, filters made from sintered metal (up to 500 C), ceramic (up to 825 C) or Hastelloy (up to 700 C) are available. The probes tested contained sintered metal filters. The measuring system has a 4 20 ma analogue output for measurement values in both variants. Variant 6888A-1OXY-4-1-5DR contains one relay output for error or warning messages, variant 6888A-1OXY-4-1-1HT with probe-internal electronics contains two. Error and warning messages are also shown on the Xi electronics display and can be identified by activating the diagnosis switch. Communication with the measuring signal converter electronics in the probe head and the Xi electronics is performed using the Xi electronics control unit. Wireless access is however also possible via HART (highway addressable remote transducer) using a THUM adapter. Adjustment is carried out via a calibration gas input which is located between the probe tube and the probe housing. The calibration gas is directed to the sensor on the probe tip via a tube within the probe with a volume flow of 2.5 l/min. In the event of repeated calibration gas injection it is important to reproduce the volume flow of 2.5 l/min as exactly as possible, otherwise measured value deviations can occur. The reference gas input is located directly next to the calibration gas input. The reference gas flows from there via an extra gas line to the reference gas side of the sensor. The reference gas consists predominantly of instrument air (20.95 Vol.-% O 2 ). The sensor must be permanently supplied with reference air with approx. 1 l/m when used at the exhaust gas duct. qal1.de info@qal1.de page 4 of 6

General notes This certificate is based upon the equipment tested. The manufacturer is responsible for ensuring that on-going production complies with the requirements of the EN 15267. The manufacturer is required to maintain an approved quality management system controlling the manufacture of the certified product. Both the product and the quality management systems shall be subject to regular surveillance. If a product of the current production does not conform to the certified product, TÜV Rheinland Energie und Umwelt GmbH must be notified at the address given on page 1. A certification mark with an ID-Number that is specific to the certified product is presented on page 1 of this certificate. This can be applied to the product or used in publicity material for the certified product. This document as well as the certification mark remains property of TÜV Rheinland Energie und Umwelt GmbH. With revocation of the publication the certificate loses its validity. After the expiration of the certificate and on requests of the TÜV Rheinland Energie und Umwelt GmbH this document shall be returned and the certificate mark must not be employed anymore. The relevant version of this certificate and its expiration is also accessible on the internet: qal1.de. Certification of Model 6888A for O 2 is based on the documents listed below and the regular, continuous monitoring of the Quality Management System of the manufacturer: Initial certification according to EN 15267: Certificate No. 0000038506: 20 August 2013 Expiry date of the certificate: 22 July 2018 Test report: 936/21219899/B of 28 March 2013 TÜV Rheinland Energie und Umwelt GmbH, Cologne Publication: BAnz AT 23 July 2013 B4, chapter II, No. 1.1 Announcement by UBA from 03 July 2013 Supplementary testing according to EN 15267 Certificate No. 0000038506_01: 29 April 2014 Expiry date of the certificate: 22 July 2018 Test report: 936/21219899/C of 30 August 2013 TÜV Rheinland Energie und Umwelt GmbH, Cologne Publication: BAnz AT 01 April 2014 B12, chapter II, No. 1.1 Announcement by UBA from 27 February 2014 qal1.de info@qal1.de page 5 of 6

Calculation of overall uncertainty according to EN 14181 and EN 15267-3 Measuring system Manufacturer Emerson Process Management Rosemount Analytical Inc. Name of measuring system Modell 6888A Serial number of the candidates M-110150 / M-110152 Measuring principle Zirconia Test report Test laboratory Date of report 936/21219899/C TÜV Rheinland 2013-08-30 Measured component O2 Certification range 0-25 Vol.-% Evaluation of the cross sensitivity (CS) (system with largest CS) Sum of positive CS at zero point 0.00 Vol.-% Sum of negative CS at zero point 0.00 Vol.-% Sum of postive CS at reference point 0.17 Vol.-% Sum of negative CS at reference point 0.00 Vol.-% Maximum sum of cross sensitivities 0.17 Vol.-% Uncertainty of cross sensitivity 0.100 Vol.-% Calculation of the combined standard uncertainty Tested parameter u² Standard deviation from paired measurements under field conditions * ud 0.020 Vol.-% 0.000 (Vol.-%)² Lack of fit u lof -0.069 Vol.-% 0.005 (Vol.-%)² Zero drift from field test u d,z 0.100 Vol.-% 0.010 (Vol.-%)² Span drift from field test u d,s 0.080 Vol.-% 0.006 (Vol.-%)² Influence of ambient temperature at span u t 0.115 Vol.-% 0.013 (Vol.-%)² Influence of supply voltage u v 0.025 Vol.-% 0.001 (Vol.-%)² Cross sensitivity (interference) u i 0.100 Vol.-% 0.010 (Vol.-%)² Influence of sample pressure u p 0.085 Vol.-% 0.007 (Vol.-%)² Influence of sample gas flow u p 0.000 Vol.-% 0.000 (Vol.-%)² Excursion of measurement beam u mb 0.000 Vol.-% 0.000 (Vol.-%)² * The larger value is used : "Repeatability standard deviation at span" or "Standard deviation from paired measurements under field conditions" å ( ) Combined standard uncertainty (u C ) u c = u max, j 0.31 Vol.-% Total expanded uncertainty U = u c * k = u c * 1.96 0.60 Vol.-% 2 Relative total expanded uncertainty U in % of the range 25 Vol.-% 2.4 Requirement of 2010/75/EU U in % of the range 25 Vol.-% 10.0 ** Requirement of EN 15267-3 U in % of the range 25 Vol.-% 7.5 ** For this component no requirements in the directive 2010/75/EU on industrieal emissions are given. The chosen value is recommended by the certification body. qal1.de info@qal1.de page 6 of 6