Telecommunication Line Protectors



Similar documents
AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS

Technical Article MS-2443

A series of technology briefs spanning Tyco Electronics product portfolio

Power surges can also be generated by equipment in your facility such as:

Bourns Resistive Products

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. Secondary Transient Protection for T1/E1 Line Cards

Nexus Technology Review -- Exhibit A

Power Supplies. 1.0 Power Supply Basics. Module

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Line Reactors and AC Drives

Properties of electrical signals

LC05-6. Dual Low Capacitance TVS Array for Telecom Line-Card Applications. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

Bourns Announces New Additions to Product Palette

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

AN-4 (Midcom TN #98) LOW COST TELEPHONE LINE INTERFACE (DAA, FXO)

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

Kit Watt Audio Amplifier

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

TISP9110LDM Overvoltage Protector

RC NETWORKS SALES GUIDE

Transformer circuit calculations

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

LC03-6R2G. Low Capacitance Surface Mount TVS for High-Speed Data Interfaces. SO-8 LOW CAPACITANCE VOLTAGE SUPPRESSOR 2 kw PEAK POWER 6 VOLTS

RS-422 and RS-485 Application Note

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

Electrical Resistance Resistance (R)

Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.

Current Probes, More Useful Than You Think

CPS Y S K CPS Y S C

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Video Camera Installation Guide

LC01-6. Low Capacitance TVS for High-Speed Telecommunication Systems. PROTECTION PRODUCTS Description. Features. Applications

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

LC03-6. Low Capacitance TVS for High-Speed Data Interfaces. Features. Description. Mechanical Characteristics. Applications

AN-2 TEN KEY CONSIDERATIONS BEFORE YOU START YOUR DAA OR FXO PHONE LINE INTERFACE DESIGN

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Unit/Standard Number. High School Graduation Years 2010, 2011 and 2012

WHITEPAPER. Cable and Connector for Hiperface dsl motor drive applications

Impedance Matching. Using transformers Using matching networks

Introduction. Harmonics and IEEE 519 Page 1 of 19

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

EMI and t Layout Fundamentals for Switched-Mode Circuits

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Advanced Power Supply Topics

PowerFlex Dynamic Braking Resistor Calculator

Copper Testing for ADSL/2/2+ Qualification and troubleshooting of the local loop

ACTP250J1BJ AC Transient Protector

Balanced vs. Unbalanced Audio Interconnections

CAN Bus Transceivers Operate from 3.3V or 5V and Withstand ±60V Faults

What are the Requirements for an Accurate DSL Line Simulator? Paradyne International, France

LM117 LM317A LM317 3-Terminal Adjustable Regulator

SOC Understanding Overcurrent Circuit Protectors

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

Redline. Comfort functions. Surge Arresters. SurgeGuard. Functions. Applications. Standards. Features. Marking. plug-in

ECEN 1400, Introduction to Analog and Digital Electronics

Design Project: Power inverter

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

WHY DIFFERENTIAL? instruments connected to the circuit under test and results in V COMMON.

Module 11: Conducted Emissions

How to design SMPS to Pass Common Mode Lightning Surge Test

38 Series - Relay interface modules A

TISP4600F3, TISP4700F3 OBSOLETE

Transistor Characteristics and Single Transistor Amplifier Sept. 8, 1997

SICK AG WHITEPAPER. Information for cable manufacturers Note-2_03

Current Probes. User Manual

TAN-058 Application Note Sept 7, 2006

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

IEEE P802.3af DTE Power via MDI Task Force Presentation Phil Holland

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Yrd. Doç. Dr. Aytaç Gören

AN1826 APPLICATION NOTE TRANSIENT PROTECTION SOLUTIONS: Transil diode versus Varistor

GenTech Practice Questions

Power over Ethernet plus Isolation requirements. David Law 3Com

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Gas Discharge Tubes GTCX36-XXXM-R05 Series

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Reading: HH Sections , (pgs , )

Crosstalk effects of shielded twisted pairs

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

White Paper: Electrical Ground Rules

Content Map For Career & Technology

CHAPTER 2B: DIODE AND APPLICATIONS. D.Wilcher

An Ethernet Cable Discharge Event (CDE) Test and Measurement System

Cable Discharge Event

LM138 LM338 5-Amp Adjustable Regulators

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING


MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

Application Note 58 Crystal Considerations with Dallas Real Time Clocks

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

Fundamentals of Power

The full wave rectifier consists of two diodes and a resister as shown in Figure

UltraFED IIB. 30 MHz Far-End Device

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Diode Applications. As we have already seen the diode can act as a switch Forward biased or reverse biased - On or Off.

ENGR-2300 Electronic Instrumentation Quiz 1 Spring 2015

Three phase circuits

Transcription:

TN CR 0025 Telecommunication Line s 1.1 The nature of telecom surges The telecom services considered in this report are transported on twisted pair. Each service has two wires, or lines, sometimes called the a and b wires. Surges can thus occur from each line to ground, known as L-G or common mode, or occur across the lines, known as L-L or differential mode. The surges that occur from each line to ground, usually do so of the same magnitude at the same time, hence the name common mode. This is an important observation and derives from the fact that these twisted pairs are balanced, and hence noise signals or surge energy is coupled onto both wires equally. The receiving telecommunications equipment is looking for differential signals, and is most sensitive to noise and surges in the differential mode. That is, the telecom equipment is generally more robust against common mode L-G signals. The following diagram illustrates the idea of a common mode surge. In a similar manner, surge protection components applied from each line to ground must operate at the same time and behave in the same way. If the surge protection component on the a wire operated before the surge protection component on the b wire, then the common mode signal would be converted to a differential signal for the time period between both surge protection components operating. This phenomena is worse when independent components are used, such as two independent gas arresters. To try to minimize this problem, most protectors use a three terminal gas arrester. However, the problem is not completely eliminated as many suppose. The following oscilloscope display indicates this. In this test, an equal impulse is applied from L-G on both leads of a three terminal gas arrester. The lower, left hand side trace shows this impulse on a scale of 1us per division, where the absolute peak of this impulse is around 700V (all traces are 200V per division). The lower, central, two traces show the voltage on each of the leads of the gas arrester. Both are climbing equally, until at around 600V one half of the gas arrester fires, rapidly reducing the voltage on that lead. However, the other continues to climb until around 700V until it fires. The top central waveform shows the difference between these waveforms it is a pulse of around 600V, resulting in the damaging L-L, or differential mode! We will see later that gas arrester only protection is usually sufficient for L-G protection. Surges on balanced pairs usually start out as common mode. Telecom equipment is relatively robust to these signals. That part is the good news. Problems can arise, however, that convert these common mode signals to differential mode. If one wire in the pair actually breaks down to ground either through insulation failure or insufficient clearance at a connection point, that wire drops to ground potential, while the other pair remains at high voltage potential. Thus, a large voltage then appears across the line, converting what was a common mode (L-G on each line) surge into a damaging differential mode (L-L) surge.

So, to summarize this, the following points need to be understood: Differential, or L-L, surges are most damaging. L-G surges can get converted to damaging L-L surges. The following diagram illustrates a L-L surge. begins to flow in the surge protector, and we can measure how much surge current the protector can cope with. In practice, either waveform lets us measure the letthrough or clamping voltage of a protector, and the 8/20us current waveform lets us measure how rugged the protector is. The following two waveforms are for the IEEE type waveform. In specifying the voltage waveform, the 1.2us is roughly the rise time of the impulse, and the 50us is the time taken for the pulse to decay to half its peak value. Similarly, for the current waveform, the 8us is roughly the rise time of the impulse, and the 20us is the time taken for the pulse to decay to half its peak value. 1.2 Test impulses used to represent typical telecom surges In order to develop and test products, various standard waveshapes are commonly used. For telecom protectors there are two main generators used as follows: Generator (Standard) Voltage Waveform Current Waveform ITU K.20 5kV, 10/700us 125A, 5/310us IEEE 6kV, 1.2/50us 3kA, C62.45 8/20us 20kV,1.2/50us 10kA, 8/20us Generator output impedance 40 Ohms 2 Ohms 2 Ohms The first is the ITU (formerly CCITT) type waveform known as the 5kV, 125A, 10/700us waveform. This waveform is a relatively low energy one, and is taken to represent the type of impulse a protector might be expected to cope with if it were connected to a pair from an underground, multi-pair cable (where a nearby lightning strike would couple into, and share amongst, perhaps 200 pairs). In specifying waveforms and generators, it is important to understand that the generator only has one output, and that the voltage waveform is actually the open circuit voltage that the generator puts out, and the current waveform is the current that flows into a short circuit on the generator terminals. From a surge protection point of view, the voltage output causes the protector to conduct, and allows us to measure the maximum voltage that the protector clamps to. Once clamping occurs, current Similar graphs could be drawn for the ITU type waveform. Test waveforms let us test and compare protectors. We can measure the let-through or clamping voltage. The current waveform lets us measure how rugged a protector is. Page 2 of 6

2 Telecommunications Surge Topologies Telecom protectors can be configured in various ways. Terms often used, mis-used, and mis-understood, are Points and Stages. Referring to a protector as a so-many point protector is explained as follows: Type 2-Point 3-Point 5-Point Description The protector only has 2 connections these would connect to each wire of the pair. It is a parallel protector, not inserted in series with the pair to be protected. The protector has 3 connections these would connect to each wire of the pair, and one to ground. It is a parallel protector, not inserted in series with the pair to be protected. The protector has 5 connections there are two connections to the input of the protector, two separate connections being to the output of the protector, and one to ground. It is a series protector, inserted in series with the pair to be protected. For example, consider the circuit diagrams below. The one on the left is a 3-point protector, and other two are 5 point protectors. complex the schematic of the protector. Using the above examples, the left two protectors would be considered single stage protectors, since they contain only a single primary clamping element. The one on the right would be considered either a 2-stage protector (because it has a primary and secondary clamping element), or would be considered a 3-stage protector (because it has a primary clamping element, series current-limiting impedances, and a secondary clamping element). A schematic diagram is really the only way of determining the construction of a surge protector. Confusion exists with the meaning of Points and Stages. Use the SCHEMATIC DIAGRAM to determine what s in a protector. 3 Primary Overvoltage Protection All telecom surge protectors contain primary overvoltage protection. It is the stage of protection providing the voltage limiting function, and generally diverts the surge current to ground. Although this element could be a gas arrester, MOV, or silicon diode, it is virtually universally recognized that Asian conditions require the primary protector to be a gas arrester. Although some designs use two separate 2-terminal gas arresters, it has been shown in section 1.1 that this can cause problems, and virtually all designs now use a 3- terminal gas arrester. The selection criteria for a gas arrester is its let-through voltage (turn-on time), and its current handling capability. When tested to standard waveforms the let-through performance can vary from around 350V to 800V depending on arrester manufacturer and construction technique. 3, 5 & 5 Point s Note that this point term really does not say much about the internal construction of the protector. The center protector consists of a single gas arrester, but the one on the right consists of a gas arrester, two series impedances, and a secondary clamp element. Some people think that a 5-stage protector contains 5 internal elements. Now that we ve looked at these examples, we know better. Which brings us to Stages. There is no universal agreement on exactly what constitutes an n-stage protector. The idea is that the more stages, the more The surge handling capability is usually determined by the primary overvoltage protector, but may actually be limited by wiring that fuses or other weaker link. The normal values for 3-terminal gas arresters are 5kA or 10kA 8/20us from each line to ground. One final point. Some gas arresters are fitted with a failsafe shorting clip. In the event that high AC currents find themselves on the pair and the arresters fires and does not go out, it is possible for it to heat to the point where it could cause a fire. The function of the fail-safe shorting clip is to react in this situation and irreversibly short out the gas arrester. This activation usually occurs by melting solder or plastic piece. This scenario is usually caused by direct contact of the pair with AC voltages, and generally not by induction. Page 3 of 6

4 Secondary Overvoltage Protection A premium telecom surge protector will have a secondary overvoltage clamping element. This is usually configured from line to line and is either a MOV or a silicon diode. A schematic for such a device is shown: The secondary element is generally a purpose-designed telecom protection thyristor component. These components have developed to the point where they are robust, have excellent, instant, clamping performance, and feature low capacitance, and have rendered MOV s or Transzorb diodes obsolete in this application. The secondary L-L clamp is very important since it provides protection for the damaging L-L voltages as explained in section 1.1. The series elements are needed to coordinate the operation of the primary and secondary clamping elements. When a surge comes along, the thyristor instantly clamps, and current begins to flow through the secondary protector. In the absence of the series elements, the thyristor would clamp and prevent the gas arrester from firing, thus forcing the thyristor to take the entire surge energy. However, the current flowing through the thyristor flows through the series element (when present) causing an additional voltage drop, that added to the thyristor voltage, causes the gas arrester to fire and take the brunt of the surge energy, while the thyristor provided low let-through voltage. The series elements need to be rugged, and experience has shown that carefully selected wire wound resistors offer the best combination of low inductance and high surge current withstand. Primary gas arresters provide high energy ability. Secondary telecom thyristors provide low let-through voltage. 5 Overcurrent Protection Where AC power circuits and telecom services are run in close proximity for large distances, usually external to the building, another problem can occur. That is, a line to ground fault on the AC circuit can cause thousands of amps of fault current to flow in the AC wiring. This in turn, can couple into the too-close telecom wiring, causing several amps of AC current to flow in the telecom wiring. This current can cause failure of the telecom line cards or other terminating equipment. In many countries, there are agreements between the power utilities and the telecom providers that ensure adequate separation of these services, so this problem is not a very common occurrence. The normal way to protect against this problem, is to have PTC s in series with each line of the telecom surge protector. These act like solid-state resettable fuses, and are normally arranged to operate at around 200mA, a value chosen to be above the normal telecommunication line current, yet below the value at which damage occurs. Like many good ideas, there is a down-side to providing PTC s in the circuit. They need to be carefully matched in resistance value to avoid unbalancing the line. Not only does their initial un-tripped resistance need to be matched (which is difficult with this type of component), but these PTC s typically do not return to their initial pretripped resistance after resetting. Thus, their degree of unbalance gets worse with subsequent tripping. Unbalance causes crosstalk into adjacent circuits, with the problem getting worse with higher frequency services. Impedance Balance and Return Loss are other measures used to assess the degree of unbalance, and the suitability for high frequency use. Given that this type of overcurrent protection is often not required, it is not usually provided in order to avoid problems with Impedance Balance and resultant crosstalk. Overcurrent protection is often not required due to the cooperative agreement between power and telecom utilities. Provision of overcurrent protection can cause crosstalk problems. 6 Frequency Response A plain ordinary telephone service (POTs) provided on 600 Ohm twisted copper pair requires a bandwidth of 300Hz to 3400Hz. At these low frequencies, provision of Telecom Surge Protection rarely provides attenuation problems. However, with the trend to ever higher frequencies required to support digital services, the issue of the Page 4 of 6

attenuation caused by the surge protection can no longer be ignored. Surge protectors can inadvertently attenuate the telecom signal by virtue of series impedance and shunt capacitance. Series impedance need to be of low resistance and especially of low inductance. The resistance component produces a fixed attenuation independent of frequency, but any inductance present causes increasing attenuation with frequency. Similarly, shunt capacitance causes attenuation that gets worse with increasing frequency. The series impedance problem is generally solved by choosing low inductance resistors. The ideal resistance value from a surge protector point of view is around 8 to 10 ohms, but can be dropped to less than half that with a suitably rugged secondary protection element. For extremely low attenuation, a gas arrester only protector is used. As discussed, thyristor elements are typically used for secondary clamping elements as their capacitance is lower than MOVs by an order of magnitude or more. However, if even more reduction in capacitance is required, an ingenious arrangement of putting the thyristor within a diode bridge is used. The diodes are chosen to be able to withstand the same surge energy as the thyristor, but they are inherently very low capacitance devices. The resultant capacitance of a larger capacitance in series with a smaller one is lower than either one. So, the bridge arrangement gives a very low overall capacitance at the expense of a few volts added to the let-through voltage (and the cost of the diodes themselves). Need to consider attenuation of protector on telecom signals. Secondary protection CAN be provided with low attenuation. 7 Comparison of some Telecom Surge s 7.1 s Compared For the purposes of comparing and contrasting the previous points, three surge protectors available from ERICO for the Asian market for the KRONE-LSA disconnect distribution block have been chosen: a) CRITEC SLP10-K1F b) CRITEC HSP10-K230 c) CRITEC SLP1-K2 Note: KRONE and Krone-LSA are registered trademarks of KRONE GmbH, Germany. CRITEC is a registered trademark of ERICO, Inc., USA. Page 5 of 6

7.2 Physical and Descriptive Comparison Description Schematic Photos CRITEC SLP10-K1F A 230V gas arrester only, 10 pair protector. CRITEC HSP10- K230 A 230V primary gas arrester with decoupled low capacitance secondary thyristor, 10 pair protector. CRITEC SLP1-K2 A 230V primary gas arrester with decoupled secondary thyristor, single pair protector. 7.3 Performance Comparison Pairs protected Primary GDT Secondary Clamp Let-through Voltage Analogue Bandwidth Digital Performance CRITEC SLP10-K1F 10 Yes - 10kA No 350 V typ. 12 MHz 8 Mbits CRITEC HSP10-K230 10 Yes - 10kA Yes 270 V typ. 12 MHz 8 Mbits CRITEC SLP1-K2 1 Yes - 10kA Yes 250 V typ. 3 MHz 2 Mbits Notes: a) The 10 pair protectors offer much lower per-pair cost than the single pair protectors. b) Let-through figures are for the slower rise time ITU 5kV, 125A, 10/700us impulse. Faster impulses such as the IEEE 6kV 1.2/50us, 3kA 8/20us impulse have the effect of increasing the performance gap between those protectors with secondary protection and those without. 8 Conclusions In determining the type of protector to employ, it needs to be understood how the various circuit topologies affect both the level of protection provided, and the underlying telecommunications signal. Given this, the three protectors above are rated as follows: CRITEC SLP10-K1F CRITEC SLP1-K2 CRITEC HSP10-K230 Good protector, giving reasonable protection, and allowing high frequency use. Better protector, giving excellent protection, and allowing reasonably high frequency use. Best protector, giving excellent protection, and allowing high frequency use. Page 6 of 6