Area of Rescue Assistance Communication System ADA Code Applicable excerpts:



Similar documents
Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

Common ADA Errors and Omissions in New Construction and Alterations

Common ADA Errors and Omissions in New Construction and Alterations

ADA Checklist for Polling Places

MEANS OF EGRESS CHAPTER 10

MEANS OF EGRESS CHAPTER 10

MEANS OF EGRESS CHAPTER 10

MEANS OF EGRESS CHAPTER 10

New York City Department of Buildings

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

The emergency provisions affect the following Building Code sections:

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

Walking and Working Surface Checklist:

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

City of Wichita, Kansas Americans with Disabilities Act Transition Plan Main Library Address

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

Building Code Clarifications - 7. Fire Resistance

FIRE AND LIFE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS

CHAPTER 10 MEANS OF EGRESS. User Note: See Preface page iv ("marginal markings" for Chapter 10 reorganization information.)

2010 FLORIDA BUILDNG CODE, FIRE AND LIFE SAFETY i

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

ELECTRONIC HEALTH RECORDS AND WRITING SURFACES

Certification: Building Plans Examiner. Exam ID: B3

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

The replacement or modification of existing windows shall comply with the following requirements:

New York City Department of Buildings

SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES (Adopted by the State of Oregon)

FIRE-RESISTANCE-RATED CONSTRUCTION

Indiana Building Rehabilitation Standard

Errata has been identified as follows:

EVACUATION OF DISABLED PEOPLE (Document under constant review)

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

FIRE-RESISTANCE-RATED CONSTRUCTION

2012 IBC & 2012 NFPA 101 Significant Means of Egress Changes. Questions Design Occupant Load Means of Egress Capacity Determination


Page 4 of 17. Committee Input NFPA 101 Coordinate Smoke detector versus smoke alarm terminology.

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

MEANS OF EGRESS CHAPTER 10

AUSTRALIAN HUMAN RIGHTS COMMISSION NOTICE OF DECISION ON APPLICATION FOR TEMPORARY EXEMPTIONS: AUSTRALASIAN RAILWAY ASSOCIATION

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

REVIEW ON FIRE REGULATIONS FOR NEW HIGH-RISE COMMERCIAL BUILDINGS IN HONG KONG AND A BRIEF COMPARISON WITH THOSE IN OVERSEAS

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

2007 ICC FINAL ACTION AGENDA

COMMERCIAL ACCESSIBILITY PLAN REVIEW CHECKLIST

Chapter 2 MEANS OF ESCAPE

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

EXAM GUIDE. Schematic Design. Overview 2. Interior Layout Vignette 3 Sample Passing Solution 5 Sample Failing Solution 6

ACCESS AUDIT OF WESTPORT HOUSE

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

Excerpts from the Canadian National Building Code (NBC)

Classroom Door Security & Locking Hardware

Expanding Your Market

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

CAL FIRE/San Luis Obispo County Fire Fire Prevention Bureau

Fire Alarm Systems Requirements by Occupancy Type

City of Auburn Americans with Disabilities Act (ADA) Transition Plan for Curb Ramps, Sidewalks, and Pedestrian Signals ADA TRANSITION PLAN

REQUIREMENT 3. Usable Doors

Residential Decks. Planning and Development Services Department

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Overview of Hotel Fire Safety Requirements

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

Building Control Guidance Note

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Required Certification Documentation. Contractor's installation certification for range hood fire suppression systems.

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

PEOPLE FIRST. How to Plan Events Everyone Can Attend. Braille Accessible Print Assistive Listening Systems

Signage - Improving access

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Number of Sides Required to Have a Handrail

NFPA 72. Exception No. 1: Where ambient conditions prohibit installation of automatic smoke detection, automatic heat detection shall be permitted.

Healthcare Engineering. Code Summary Report

Life Safety Code Enabling References

NFPA Frequently Asked Questions

GENERAL FIRE SAFETY TERMS & DEFINITIONS

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

FIRE SAFETY INSPECTION REPORT

Lori Greene, AHC/CDC, CCPR, FDAI

City of Riverside Building & Safety Division Phone: (951)

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Fire Alarm System Plans Review Checklist Property location Date of Review

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

General Fire Code Requirements Within Commercial Tenant Spaces

COMMONLY USED RESIDENTIAL BUILDING CODES

NFPA SELECT SIGNIFICANT CHANGES

FIRE AND SMOKE PROTECTION FEATURES

Introduction. CE marked construction products

Mobile Fire Rescue Department Bureau of Fire Prevention

BS5839 Part 1:2002 Overview

Transcription:

Area of Rescue Assistance Communication System ADA Code Applicable excerpts: CONTENTS (Guidelines and Definitions) Page 1 Area of Rescue Assistance Requirements Page 2 Emergency Communication Equipment Requirements Page 3 Signage Requirements (Illuminated and Non-Illuminated) Page 3 Physical Location of Equipment (Clear Space and Protrusions) Page 4 Elevator Requirements (Emergency Communications and Call Buttons) Page 5 Guidelines that apply to Area of Rescue Assistance communication equipment are covered under a number of sections spread throughout the Code. To leaf through the legislative text and discover the pertinent sections can involve considerable research time. We are providing the following information as a quick reference to help specifiers in evaluating and specifying equipment for Area of Rescue Assistance communications. The following sections are reprinted for the reader's convenience from the Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities, Federal Register Volume 56, No. 144, July 26, 1991. Please note that this is not a complete reprint of all sections concerning this equipment, and that we do not make any such claim. We are not responsible for any errors or omissions. For further reference, the Federal Judiciary has set up a Technical Assistance Board which may be reached at 1-800-949-4232. 3.5 Definitions Area of Rescue Assistance: An area, which has direct access to an exit, where people who are unable to use stairs may remain temporarily in safety to await further instructions or assistance during emergency evacuation. 4.1.3 Accessible Buildings: New Construction Accessible buildings and facilities shall meet the following minimum requirements: (9)* In buildings or facilities, or portions of buildings or facilities, required to be accessible, accessible means of egress shall be provided in the same number as required for exits by local building/life safety regulations. Where a required exit from an occuplable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in a number equal to that of inaccessible required exits). Areas of rescue assistance shall comply with 4.3.11. A horizontal exit, meeting the requirements of local building/life safety regulations, shall satisfy the requirements for an area of rescue. EXCEPTION: Areas of rescue assistance are not required for buildings or facilities having a supervised automatic sprinkler system. Housing Devices, Inc. Page 1 Reprinted June 98

AREAS OF RESCUE ASSISTANCE (4.3.11) 4.3.11.1 Location and Construction An area of rescue shall be one of the following: (1) A portion of a stairway landing within a smoke-proof enclosure (complying with local requirements). (2) A portion of an exterior balcony located immediately adjacent to an exit stairway when the balcony complies with local requirements for exterior exit balconies. Openings to the interior of the building located within 20 feet (6m) of the area of rescue assistance shall be protected with fire assemblies having a three-fourths hour fire protection rating. (3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire resistive construction and for openings) located immediately adjacent to an exit enclosure (4) A vestibule located immediately adjacent to an exit enclosure and constructed to the same fire resistive standards as required for corridors and openings. (5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and separated from the interior of the building with not less than one-hour fire-resistive doors. (6) When approved by the appropriate local authority, an area or a room which is separated from other portions of the building by a smoke barrier. Smoke barriers shall have a fire-resistive rating of not less than one hour and shall completely enclose the area or room. Doors in the smoke barrier shall be tight-fitting smoke-and draftcontrol assemblies, have a fire-protection rating of not less than 20 minutes and shall be self-closing or automatic closing. The area or room shall be provided with an exit directly to an exit enclosure. Where the room or area exits into an exit enclosure which is required to be of more than one-hour fire-resistive construction, the room or area shall have the same fire-resistive construction, including the same opening protection, as required for the adjacent exit enclosure. (7) An elevator lobby with elevator shafts and adjacent lobbies are pressurized as required for smoke-proof enclosures by local regulations and when complying with requirements herein for size, communication, and signage. Such pressurization system shall be activated by smoke detectors on each floor located in a manner approved by the appropriate local authority. Pressurization equipment and its ductwork within the building shall be separated from other portions of the building by a minimum two-hour fire-resistive construction. 4.3.11.2. Size Each area of rescue assistance shall provide at least two accessible areas each being not less than 30 inches by 48 inches (760 mm by 1220 mm). The area of rescue assistance shall not encroach on any required exit width. The total number of such 30-inch by 48-inch (760 mm by 1220 mm) areas per story shall not be less than one for every 200 persons of calculated occupant load served by the area of rescue assistance. EXCEPTION: The appropriate local authority may reduce the minimum number of 30-inch by 48-inch (760 mm by 1220 mm) areas to one for each area of rescue assistance on floors where the occupant load is less than 200. 4.3.11.3 Stairway Width Each stairway adjacent to an area of rescue assistance shall have a minimum clear width of 48 inches between handrails. 4.3.11.5 Identification Each area of rescue assistance shall be identified by a sign which states "AREA OF RESCUE ASSISTANCE" and displays the international symbol of accessibility. The sign shall be illuminated when exit sign illumination is required. Signage shall also be installed at all inaccessible exits and where otherwise necessary to clearly indicate the direction to areas of rescue assistance. In each area of rescue assistance, instruction on the use of the area under emergency conditions shall be posted adjoining the two-way communication system. Housing Devices, Inc. Page 2 Reprinted June 98

COMMUNICATIONS EQUIPMENT 4.3.11.4 Two-Way Communication A method of two-way communication, with both visible and audible signals, shall be provided between each area of rescue assistance and the primary entry. The fire department or appropriate local authority may approve a location other than the primary entry. A4.3.11.4 Two-way Communication It is essential that emergency communication not be dependent on voice communications alone because the safety of people with hearing or speech impairments could be jeopardized. The visible signal requirement could be satisfied with something as simple as a button in the area of rescue assistance that lights, indicating that help is on the way, when the message is answered at the point of entry. A4.10.14 Emergency Communications A device that requires no handset is easier to use by people who have difficulty reaching. Also, small handles on handset compartment doors are not usable by people who have difficulty grasping. Ideally, emergency two-way communication systems should provide both voice and visual display intercommunication so that persons with hearing impairments and persons with vision impairments can receive information regarding the status of a rescue. A voice inter-communication system cannot be the only means of communication because it is not accessible to people with speech and hearing impairments. While a voice intercommunication system is not required, at minimum, the system should provide both an audio and visual indication that a rescue is on the way. SIGNAGE (4.30) 4.30.1 General Signage required to be accessible by 4.1 shall comply with the applicable provisions of 4.30. 4.30.2 Character Proportion Letters and numbers on signs shall have a width-to-height ration between 3:5 and 1:1 and a stroke-width-to-height ration between 1:5 and 1:10. 4.30.3.1 Character Height Characters and numbers on signs shall be sized according to the viewing distance from which they are to be read. The minimum height is measured using an upper case X. Lower case characters are permitted. Height Above Minimum Finished Floor Character Height Suspended or Projected 3" (75mm) Overhead in compliance minimum with 4.4.2 4.30.4 Raised and Brailled Characters and Pictorial Symbol Signs (Pictograms) Letters and numerals shall be raised 1/32 in. upper case, sans serif or simple serif type and shall be accompanied with Grade 2 Braille. Raised characters shall be at least 5/8 in. (16mm) high, but no higher than 2 in. (50 mm). Pictograms shall be accompanied by the equivalent verbal description placed directly below the pictogram. The border dimension of the pictogram shall be 6 in. (152 mm) minimum in height. Housing Devices, Inc. Page 3 Reprinted June 98

PHYSICAL LOCATION OF THE EQUIPMENT: Clear Floor or Ground Space for Wheelchairs (4.2.4) 4.2.5 Forward Reach If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in. (1220 mm) (see Fig. 5(a)). The minimum, low forward reach is 15 in. (380 mm). If the high forward reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b). 4.2.6.1.1 Side Reach If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in. (1370 mm) and the low side reach shall be no less than 9 in. (230 mm) above the floor (Fig. 6(a) and (b)). If the side reach is over an obstruction, the reach and clearances shall be as shown if Fig. 6(c). 4.4 PROTRUDING OBJECTS 4.4.1 General Objects Projecting from walls (for example, telephones) with their leading edges between 27 in. and 80 in. (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in. (100 mm) into walks, halls, corridors, passageways, or aisles (see Fig. 8(a)). Objects mounted with their leading edges at or below 27 in. (685 mm) above the finished floor may protrude any amount (see Fig. 8(a) and (b)). Freestanding objects mounted on posts or pylons may overhang 12 in. (305 mm) maximum from 27 in. to 80 in. (685 mm to 2030 mm) above the ground or finished floor (see Fig. 8(c) and (d)). Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig. 8(e)). 4.4.2. Head Room Walks, halls, corridors, passageways, aisles or other circulation spaces shall have 80 in. (2030mm) minimum clear head room (see Fig. 8(a)). If vertical clearance of an area adjoining an accessible route is reduced to less than 80 in. (nominal dimension), a barrier to warn blind or visually impaired persons shall be provided (see Fig. 8(c-l)). Housing Devices, Inc. Page 4 Reprinted June 98

ELEVATORS (From the elevator section, to illustrate typical requirement for emergency communication and call buttons). 4.10.14 Emergency Communications If provided, emergency two-way communication systems between the elevator and a point outside the hoistway shall comply with ASME A17.1-1990. The highest operable part of a two-way communication system shall be a maximum of 48 in. (1220 mm) from the floor of the car. It shall be identified by a raised symbol and lettering complying with 4.30 and located adjacent to the device. If the system uses a handset then the length of the cord from the panel to the handset shall be at least 29 in. (735 mm). If the system is located in a closed compartment the compartment door hardware shall conform to 4.27. Controls and hardware shall conform to 4.27. Controls and Operating Mechanisms. The emergency intercommunication system shall require both voice communication and visual indicators. 4.10.3 Hall Call Buttons (Elevator Lobbies and Halls) Call buttons in elevator lobbies and halls shall be centered at 42 in. (1065 mm) above the floor. Such call buttons shall have visual signals to indicate when each call is registered and when each call is answered. Call buttons shall be a minimum of ¾ in. (19 mm) in the smallest dimension. The button designating the up direction shall be on top. (See Fig. 20) Buttons shall be raised or flush. Objects mounted beneath hall call buttons shall not project into the elevator lobby by more than 4 in. (100mm). 4.10.12 Car Controls Elevator control panels shall have the following features: (1) Buttons. All control buttons shall be at least 3/4 in. (19mm) in their smallest dimension. They shall be raised or flush (2) Tactile, Braille, and Visual Control Indicators. All control buttons shall be designated by Braille and by raised standard alphabet characters for letters, Arabic characters for numerals, or standard symbols as shown in Fig. 23 (a), and as required in ASME A17.1-1990. Raised and Braille characters and symbols shall comply with 4.30. The call button for the main entry floor shall be designated by a raised star at the left of the floor designation (See Fig. 23(a)). All raised designations for call buttons shall be placed immediately to the left of the button to which they apply. Applied plates, permanently attached, are an acceptable means to provide raised control designations. Floor buttons shall be provided with visual indicators to show when each call is registered. The visual indicators shall be extinguished when each call is answered. (3) Height. All floor buttons shall be no higher than 54 in. (1370 mm) above the finish floor for side approach and 48 in. (1220 mm) for front approach. Emergency controls, including the emergency alarm and emergency stop, shall be grouped at the bottom of the panel and shall have their centerlines no less than 35 in. (890 mm) above the finish floor (See Fig. 23(a) and (b)). Housing Devices, Inc. Page 5 Reprinted June 98