33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application



Similar documents
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MCR1900 Media Converter 19-Slot Chassis

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Cisco Unified IP Phone Power Injector

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

HMI display Installation Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

AXIS T81B22 DC 30W Midspan

TMS TANK MANAGEMENT SYSTEM

LIEBERT VNSA Installation Sheet

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Telephone- and leased line modem for industrial applications TD-36

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Cross-beam scanning system to detect slim objects. 100 mm in

Moxa EtherDevice Switch

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Power Supplies 3. SDN-P DIN Rail Series

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

8-Port PoE Network Switch

UMEC International Corporation

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

RY2 miniature industrial relays

2M IR Mini Dome Quick Installation Guide

BITMAIN. APW PSU Series User Guide

100 - SERIES NETWORK SWITCHES QUICK START GUIDE

ST Series POWER SUPPLIES USER INSTRUCTIONS

650W Single Output Power Supply

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Operating Manual UWAPS-TINY Series

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

EGSTON Standard E2xFxWx 12W

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

User manual Rev. 1.2 (17/04/2015)

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Silvertel. Ag9800M. 1. Features. 2. Description. Miniature PoE Module. Small SMT package. IEEE802.3af compliant. Low cost

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

BB800 Off-Grid Solar System

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Emergency lighting units EM powerled

HP UPS R1500 Generation 3

Linear Luminaire with LED Series EXLUX 6402/2

AXIS 291 1U Video Server Rack Installation Guide

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

DTS-HAZ DTS-HAZ-DC. Installation Instructions. for use with Self-Regulating, Constant Wattage & Mineral Insulated Electric Heating Cables

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Power supply unit Model: PAC-SC50KUA

Analog signal converters CC-E I/I Current / current isolators

Duct Humidity Transmitter

MAJORSINE Power Inverter

Three-phase monitoring relay CM-PFE

2013 Wireless Video Intercom INSTALLATION GUIDE

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

RM4TG20 three-phase network control relay RM4-T - range V

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Canopy Surge. User Manual

ADM1TE 5/30A DIN rail single phase two wire energy meter

Mini USB and USB 2.0-IP67 Connector System

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /01/02

Advantium 2 Plus Alarm

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Explosion proof enclosures

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Single Output Switching Power Supply

Digital input modules

Waterproof Connectors for Outdoor Use

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Transcription:

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection OCP, OVP Gigabit Compatible 1 Year Warranty IP67 Rating (Waterproof) Non-Vented Case with Mounting Bracket Applications Outdoor Security Cameras Outdoor Emergency Lighting Outdoor Wireless Access Points Safety Approvals CE cul/ul Mechanical Characteristics (without Mounting Bracket) Length: 252.1mm (9.93in) Height: 78mm (3.07in) Width: 176mm (6.93in) Weight: 1.7Kg (3.75lb) Mechanical Characteristics (with Mounting Bracket) Length: 300mm (11.81in) Height: 82mm (3.23) Width: 184mm (7.24in) Weight: 2.83kg (6.24lb) Output Specifications Model POE33U-1AT DC Output Voltage 56V Load Regulation Min. Max. Line Load 0A 0.60A 54-57Vdc under all conditions Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the most up-to-date specifications and contact information.

POE33U Characteristics INPUT: AC Input Voltage Range 90 to 264VAC AC Input Voltage Rating 100 to 240VAC AC Input Current 1.0A (RMS) and 90VAC at maximum load.55a (RMS) and 240VAC at maximum load AC Input Frequency 47 to 63Hz Leakage Current 3.5mA for 254VAC, 50Hz Max Inrush Current 30A for 115VAC at maximum load 60A for 230VAC at maximum load OUTPUT: Total Output Power 33.6W Ripple and Regulation 250mV maximum Efficiency 70% (typical) at maximum load, and 120VAC 60Hz ENVIRONMENTAL: Temperature Operation Non-operation -40 to +60 C -40 to +85 C Humidity Operation 5 to 90% EMI FCC Part 15 Class B EN55022 Class B Isolation Test Primary to Secondary: 4242 VDC for 1 minute, 10mA Primary to Field Ground: 2121VDC for 1 minute, 10mA Output to Field Ground: 2121VDC for 1 minute, 10mA Immunity ESD: IEC61000-4-2 Level 3 RS: IEC61000-4-3 Level 3 EFT: IEC61000-4-4 Level 2 Surge: IEC61000-4-5 Level 3 CS: IEC61000-4-6 Level 3 Voltage Dips IEC61000-4-11 Harmonic: EN61000-3-2 Class A Insulation Resistance Primary to Secondary: >10M OHM 500VDC Primary to Field Ground: >10M OHM 500VDC FEATURE: Over Voltage/Current, Short Circuit Protection The output is equipped with short-circuit, over-voltage and over-load protection as per the 802.3at specification, and conforms to UL60950-1 paragraph 2.2.3. The output can be shorted permanently without damage Indicators LED 1: Input power ON LED 2: Detected a valid IEEE802.3at Class 4 load LED 3: Detect and Connected to a valid IEEE802.3af load Input Connector 3 pin terminal block with M3.5 screw terminal; for appropriate connection use minimum 14AWG wire and M3.5 spade lug Output PoE Connector RJ45 Output PoE Connection +pins 3, 6 / -pins 1, 2 Input/Output Case Ports 3 ¾ NPT holes compatible with standard ¾ NPT conduit piping or Phihong wire gland PGLAND750 with fully waterproof AC and RJ45 cables. Network Switch Network Switch must be Environment Rated B as per paragraph 33.4.1.1 of the IEEE802.3at standard. Warranty 1 Year

POE33U Dimension Diagram unit:mm PGLAND750 Dimension Diagram unit:mm

Safety Procedures General Precautions General - Please read the following precautions carefully before installing and connecting the system to a power source. Note Only qualified and trained service personnel (in accordance with IEC 60950 and AS/NZS 3260) should install, replace, or service the equipment. Install the system in accordance with Country, National or to the U.S. National Electric Code if you are in the United States. Precautions: 1. The building facilities in which the product will be used must provide Isolation to the main AC Input connector. This connection requires a fuse or circuit breaker no larger than 20A for 120 VAC (U.S.A.) or 16A, 230 VAC (international). The building facilities must protect the PoE33U Power injector from over current or short-circuits. 2. The POE33U power injector enclosure is IP67 tested which provides degrees of protection against access to hazardous parts, dust and against ingress of water. To ensure protection against ingress of water, torque captive screws (4 places) in an X pattern to > 27 inch pound. Only qualified service personal should install, replace or service this equipment. Before connecting, visit www.midspans.com for the latest up to date specification and contact information. 3. The POE33U power injector enclosure must be mounted vertically but not orientation limited. The enclosure is provided with a steel 2mm thick zinc plated mounting bracket. When mounting utilize the holes in the mounting bracket plate (10mm holes) 8 places. The preferred method of mounting is to a vertical 4 inch or 6 inch pole using 2 3/8 x 16 U-bolts. If mounting on a flat surface, to sheetrock or wood and or others material, use 4 M6 fasteners. Other fasteners may be used, but hardware must be sized to support 4-5 times the weight of the unit. 4. The POE33U power injector enclosure has 3 threaded (¾ NPT) openings to accommodate waterproof / water tight conduit and or cable glands. WARNING: To ensure protection against ingress of water, the connection(s) of the conduit and or cable glands are threaded with Teflon tape all the way through the holes in an enclosure wall. 5. The POE33U power injector AC input connector (located inside enclosure) is a 3 pin terminal block 9.5mm, rated 20 A, 250 V, with M3.5 Nickel Plated steel screws. The incoming 3 wire/cable must be minimum 14AWG and or in accordance with Country, National Electric Code. 6. The POE33U Power injector consists of Data & Power ports. The ports are providing TNV-1 outputs. The ports use RJ-45 data sockets. Do not connect telephone cables into these ports. Only RJ- 45 data cables with waterproof / water tight connections may be connected to these sockets. 7. To prevent the POE33U Power injector from overheating, do not operate the product in an area that exceeds the maximum recommended ambient temperature of -40 ºC to +60 ºC. 8. Do not work on the POE33U Power injector or connect or disconnect cables, during periods of lightning activity. 9. The AC connector wire combination must be accessible at all times, as it serves as the main disconnect device to the product. 10. Before servicing the product, always disconnect the product from its AC source. 11. Equipment is for Pollution degree 2 Environment. 12. Disposal of this product should abide by all appropriate National laws and regulations.

Installation Instructions 1) The unit is packaged fully closed with the mounting bracket pre-installed; remove from packaging and loosen the four captive screws located at the top of the midspan so that the lid can be lifted easily. 2) Using a Philips screwdriver, remove the four screws holding the protective covering for the PC Board, and the two screws for the protective covering over the AC terminal block. 5) Thread outdoor rated waterproof AC cable (must comply with all local, national and country electrical codes) from source through piping/gland to the terminal block. The AC cable will need to be a minimum of 14AWG and terminated with M3.5 spade lugs. Pair and secure ground, line, and neutral to the appropriate positions on the three pin terminal block and reattach the protective covering. Note: if using the cable gland PGLAND750, the outer seal nut needs to be fully tightened to close rubber seal to protect against ingress of water. 3) Connect cable glands (PGLAND750) or ¾ NPT conduit piping to the face of the midspan. Ensure that connectors are fully installed to guarantee waterproof operation. 6) Using waterproof outdoor rated Cat5e Ethernet cable, thread through cable glands or conduit piping to the appropriate RJ45 connector and ensure each portal is properly sealed. 4) To better enable waterproof operation it is recommended that installers use Teflon tape to cover threads before installation. Users may also wish to use silicon sealant to further protect from ingress of liquid. 7) Reattach the protective covering over the PC board and terminal blocks and re-close the lid. Ensure that the four captive screws are fully tightened before operation can commence.