PURE : REliable planning of data center cabling

Similar documents
Product Information 19 / 45HU Data-Center-Rack (Cabinet)

BLINK Triple-Play Connector

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Polymer Coated Fiber Cable (PCF)

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

LANC Fibre Patch Panel Solution

HARTING Ethernet Cabling 8-poles Overview

MPO. Fast Fibre Solution for Data Centres

BLACK BOX. Secure network ports from unauthorized access and accidental disconnects.

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Accelerating Light. Copper Cabling Solutions. Category 6A

AMP NETCONNECT Data Center Cabling Solutions

DOUBLE STAINLESS STEEL TUBE DTS FIBER OPTIC CABLE FTSF-FSUTS(DTS)

HUBER+SUHNER AG Phil Ward

Fiber Optic Specifications

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

How To Make A Fibre Cable For A Data Centre

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

DIAMOND AVIM Connector

4RU High Density Shelf Installation Instructions

Copper Pre-terminated Assemblies

Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U

DIGITUS Network & Server Cabinets. UNIQUE Series

Plug & Play Universal Systems

What testing is required for PREMISES Fiber Optic Cabling and the standards used

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

MERO Floor Systems - CleanRoom

Excel Pre-terminated Copper and Fibre Optic Systems

Fiber-optic cable drums. Mobile. Robust. Individual. Excellence, that connects. Sachsenkabel Cable drums

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Optical Fiber. Smart cabling: constructing a cost-effective, reliable and upgradeable cable infrastructure for your enterprise network

SERVER ROOM CABINET INSTALLATION CONCEPTS

Network Design. Yiannos Mylonas

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

InstaPATCH ZERO Solution Guide

HARTING Ethernet Cabling 4-poles Overview

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

DATA CENTER SOLUTIONS. MTP cables Patchcords Cat 6A PDU

Pretium Connector Housings

Loss & Continuity Testing with MPO/ MTP Connectors

Cable management for rack-mounted systems

The color scheme for the fibers in the cable complies with the Telcordia (formerly Bellcore) specification.

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

7.4 3M No Polish Connector

LOW LOSS CABLE PAG. 1

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Optical Power Meter. Specification & User Manual

Secure/Keyed LC System Solutions Overview

19 DYNAmax Free Standing Server C A B I N E T s

Category 6 UTP - Cabling System

Mini USB and USB 2.0-IP67 Connector System

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

Pretium EDGE HD Solutions

ADC Structured Cabling Solutions

Enabling 21 st Century Connectivity

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

GOWN. Central Loose Tube Cables Outdoor, Steel Wire Armor (SWA) A-DQ(ZN)2YB2Y Full Rodent Protection. Ordering Information.

Reliable, Consistent, Quality

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

Network Monitoring - Fibre TAP Modules

FullAXS CONNECTOR SEALING & CABLE ASSEMBLY

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

Auxiliary equipment for communication with the EuroProt protective devices

19 DYNAmax Free Standing Server C A B I N E T s

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

Site Solutions Next Generation Site Solutions for All Architectures

Solar Mounting System

How To Make A Data Center More Efficient

Data Centre & Enterprise Solutions. RapidNet

IN LEITERPLATTEN INTEGRIERTE OPTISCHE VERBINDUNGSTECHNIK AUF DÜNNGLASBASIS

Fibre optic testing best practices

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

How To Properly Maintain A Fiber Optic Infrastructure

Simpler all over. Simpler all round. 500 MHz. 10 GB ether. fully shielded. Poe+ Cat.6 A. Data Voice. MFP8 Cat.6 A Field assembly RJ45 plug

Specifying Optical Fiber for Data Center Applications Tony Irujo Sales Engineer

Knürr DCM. Knürr DCM. 19 Server Rack System 19 Heavy Duty Rack 1.2 to

Discontinued. Volition. Fiber Optic Cable. 3Innovation

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

PANDUIT is a Technology Developer Partner for Storage Networking Hardware. FIBER OPTIC CABLING SYSTEM SOLUTIONS B EYOND T HE G LASS

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Fiber in the Data Center

MapIT G2 Infrastructure Management

Times Microwave Systems Hermetically Sealed Assemblies

Obsolete Fiber Technology? Not in my Data Center!

AMPSEAL* Automotive Plug Connector and Header Assembly

HSD High Speed Data interconnection

DATA CENTRES POWERED BY EXCEL

LwLVision-USB 2.0. Installation Guide

Transcription:

PURE : REliable planning of data center cabling

THE PURE EFFEct: TWICE AS MANY CONNEctionS AND 15 METERS MORE CHannEL LEngtH * PreCONNECT PURE is a milestone in the development of high-end IT cabling for data centers. It eliminates two uncertainty factors that are critical to overall performance in day-to-day operations: UncERtaintY FACTOR: contamination By their very nature, the optical contacts integrated in PURE interfaces make it impossible for contamination or damage to occur during installation. The LC-Duplex interface is sealed at the factory. You just snap it into the back of the front panel. UncERtaintY FACTOR: loss BUdgET PURE connectors have an extremely low, guaranteed insertion loss not just in eachto-each tests, but in real-world applications. This gives you certainty in the planning of transmission paths and allows you to implement more connections per channel. PreconnEct PURE will help to keep your data center running smoothly over the long term. But that s not all. Read the following pages to learn about details and additional features. PURE at A GLANCE Integration of optical contacts in the LC-Duplex interfaces: ruling out contamination during installation Guaranteed parameters for unused channels until they are actually used Factory-sealed to prevent improper opening and handling Insertion loss and return loss exceeding IEC 61755-5 Ed. 1.0 CD Grade Cm (multimode) Guaranteed maximum insertion loss of 0.4 db (application limit, LC multimode 50 µm) Mean insertion loss = 0.15 db (lc multimode 50 µm) Visual quality of ferrule end faces significantly better than IEC 61300-3-35 Quick, tool-free mounting with simple snap-in on the back of the panel Complete system consisting of trunk cables, patch cables, SMAP-G2 panels and racks Multimode and single mode * In relation to 1.0 db insertion loss, a channel length of 150 m and a loss budget of 1.54 db according to original Fibre Channel 16 Gb/s OM4 specification. 2/3 2/3

Dust cap with nipple Completely redesigned interface Seal Shutter PURE INNOVation: NO MORE CONTAMination, no MORE UncERtaintY ABOUT attenuation CLEan CONNEctionS: for ABSOLUTE CERtaintY Studies have shown that about 50% of all network errors are caused by cabling problems. Of these, most involve contamination of fiber-optic cable connections, improper patching or even damage arising from patching. PreconnEct PURE eliminates these causes from the start. PURE trunk cables have preassembled PURE interfaces instead of conventional connectors. The optical contacts integrated in the interfaces are factory-tested for perfect optical quality and absolute cleanliness before the seal is applied. On the patch side the LC-Duplex interfaces are sealed with protective caps, preventing contamination even if the channels are not used for a long time. The warranty permits opening of seals and patching only by certified personnel (see also page 14/15, Cabling Services). In this way PURE not only ensures maximum data transmission over long distances, it saves time and costs by at least 15%, because on-site acceptance tests and cleaning are unnecessary. insertion LOSS: APPlication LIMIT VERSUS PRODUction limit An increase in transmission speed always means a reduction in the maximum permissible attenuation of multimode links. In high-end applications it is therefore essential to keep the insertion loss of fiber-optic connections as low as possible. To impress customers, cable manufacturers often quote the so-called production limit value, which is measured using reference couplers and connectors. But this value is of no relevance to actual practice, in which standard components with varying specifications are involved. OVERAlL PRocESS CAPabilitY PURE CONNEctoRS Frequency of measurement results For this reason Rosenberger OSI always quotes the so-called application limit value for PURE. This value applies to any combination of connectors, and it s guaranteed. The value is 0.4 db*, which is 0.2 db better than the highest performance class specified in IEC 61755-5 Ed. 1.0 CD Grade Cm (see also page 6). The mean* insertion loss (il) measured for PURE components is well below this, at 0.15 db (see Overall process capability chart). This gives you a big safety margin from the application limit value. In actual practice even better values are achieved. Application limit The connection does not have to be opened during installation; thanks to the new interface design, the complete unit can be snapped into the panel from behind. MAXIMUM INSERtion LOSS PURE IEC standard* 0.00 0.06 0.12 0.18 0.24 0.30 0.36 Insertion loss in db 0.2 *IEC 61755-5 Ed. 1.0 CD Grade Cm 0.4 0.6 4/5

Overall performance: iec 61755-5 ed. 1.0 cd grade cm VERSUS pure The performance parameters for fiber-optic connections are set forth in the IEC 61753 and 61755 standards, which define grades. The highest performance class for multimode fibers is IEC 61755-5 Ed. 1.0 CD Grade Cm, which specifies a maximum insertion loss (il) of 0.6 db for 97% of the connections and a minimum return loss (RL) of 20 db. PreconnEct PURE significantly exceeds both of these values: COMPARISON OF MAXIMUM CHannEL LENGTHS* 150 m for IEC 61755-5 Ed. 1.0 CD Grade Cm INStallation: tool-free AND EaSY PURE trunk cables are preassembled with lc-duplex interfaces at both ends and sealed. Thanks to the newly designed interface with an innovative locking mechanism, each channel can easily be snapped from behind into the part front plates of the SMAP-G2 panels. PURE versus IEC 61755-5 Ed. 1.0 cd Grade Cm IL PURE Quality 50µm MM»Application limit«100% max. 0.4 db Mean 0.15 db IEC 61755-5 Ed. 1.0 CD Grade Cm (Grades Am & Bm are not covered by standards, RL Grade 2m) 97% max. 0.6 db Mean 0.35 db RL min. 40 db min. 20 db 165 m for PreconnEct PURE CoMParison of PoSSible connections* With maximum IL (0.4 and 0.6 db respectively) Cladding Core VISUal QUalitY OF THE FIBER SURfacES: in A CLASS OF ITS OWN Every connection between two optical fibers can impede the propagation of light in the channel. To minimize insertion loss it is therefore essential for the fiber ends to meet exactly and for the end faces to have as few imperfections (scratches and defects) as possible. By exercising the utmost care in manufacturing we achieve visual quality results for our PURE interfaces that are well above the requirements of IEC 61300-3-35. Thus, for any given loss budget, PreconnEct PURE permits up to twice as many connections per channel as with IEC-specified cabling. In addition, the high quality of Rosenberger OSI OM4 fibers allows elongated channel lengths (see illustration at right). 1 connection for IEC 61755-5 Ed. 1.0 CD Grade Cm VISUal QUalitY OF End FACES 2 connections for PreconnEct PURE PURE end faces without scratches and contamination ZONE SPEcification SCRatcHES DEFECTS With mean IL (0.15 and 0.35 db respectively) A: core 0-65 µm PURE MM No scratches > 2 µm No defects permitted IEC 61300-3-35 MM No scratches > 3 µm Up to 4 defects < 5 µm 2 connections for IEC 61755-5 Ed. 1.0 CD Grade Cm Fiber end faces with scratches and moderate contamination B: cladding 65-115 µm PURE MM No scratches > 3 µm Up to 5 defects < 3 µm IEC 61300-3-35 MM No scratches > 5 µm Up to 5 defects < 5 µm 6 connections for PreconnEct PURE 6/7 * Example: Fibre Channel 16 Gb/s OM4

PURE products: a perfect product line Technical Data PREconnECT Fiber Trunks CABLE Design StRANDED mini loose tubes Numbers of fibers, max. 36 48 72 96 144 LEG LENgtH STEPPED [cm] approx. 65-90 65-98 65-90 95-110 95-125 PreCONNECT PURE Trunk Application Infrastructure cabling of data centers ProPERtiES Both sides factory assembled Standard light propagation channelwise crossed Cable length up to 2,000 m, longer on request Length Definition Order length: length between the connectors at the longest legs at both sides (not between the cable dividers) Length tolerances: up to 10 m = +/- 50 cm 11 m to 30 m = +/- 100 cm 31 m to 100 m = +/- 150 cm longer than 100 m = +/- 2% Leg lengths on both sides stepped acc. to table on page 9 Cable Types With all standard loose tube cables up to 144 fibers available Cable data sheets on request FibER Types OM4 and SM Fiber data sheets on request interface lc-duplex with shutters Optional Cable with increased tensile strength and crush resistance Cable with special armoring DeliVERY FoRM Factory measured IL and RL, including measurement report Product ID labels behind both cable dividers Dependent on the length as cable ring, on cardboard or wooden drum outer [mm] 8.0 8.0 8.4 9.4 11.4 MAx. TensILE StRENgth [N] 3000 3000 3000 3000 3000 MAX. crush resistance [N/dm] 1000 1000 1000 1000 1000 MIN. blending radius [mm] static dynamic 80 120 fire load [MJ/m] 0.69 0.69 0.73 0.92 1.43 Part numbers number of fibers / INtERfACEs 80 120 SM APC 8 9/125 G.657.A1 84 126 94 141 OM4 50/125 BI 36 lc-duplex 024P0141 G657 A 024P0101 OM4 48 lc-duplex 024P0126 G657 A 024P0103 OM4 72 lc-duplex 024P0142 G657 A 024P0105 OM4 96 lc-duplex 024P0128 G657 A 024P0107 OM4 144 lc-duplex 024P0129 G657 A 024P0109 OM4 Other interfaces, fiber types and numbers of fibers on request. 114 171 8/9

PreConnect PURE PaTChCORds Applications Patchcords appropriate for use in data centers ProPERtiES Optimized kink and crush resistance with regards to application requirements Operating temperature range -10 C to +60 C, patchcords for other operating temperature ranges on request Standard light propagation: Full-duplex cables: duplex connectors at both sides acc. to ISO/IEC 11801 and EN 50173 = crossed Length TolerancES Up to 1 m = +/- 50 mm 2 m to 3 m = +/- 100 mm 4 m to 25 m = +/- 200 mm longer than 25 m = +/- 1% DUPLEx PatCHCoRD Cable type round I-V(ZN)H 2,0 mm FRNC-LSZH part numbers cable types Different FRnc-LSZH cables Cable data sheets on request FibER types OM4 und SM, bend-insensitive Fiber data sheets on request ConnectoRS lc-compact DeliVERY form Factory measured IL and RL, measurement report on request Serial number label at both cable ends for use in network documentation Product ID label on the package Each packed in a foil bag, cables longer than 100 m on cardboard drum DUPLEx PatCHCoRD Cable type round I-V(ZN)H 2,8 mm FRNC-LSZH part numbers connector LENgth SM APC 8 9/125 G.657.A1 OM4 50/125 BI lc-compact» LC-Compact Variable 087P6609 G657 A 087P6601 OM4 Other plug connection, cable- and fiber data on request. part numbers DUPLEx PatCHCoRD Cable type double-jacket-round I-V(ZN)H(ZN) 2,8/5,0 mm FRNC-LSZH connector LENgth SM APC 8 9/125 G.657.A1 OM4 50/125 BI lc-compact» LC-Compact Variable 087P6612 G657 A 087P6613 OM4 Other plug connection, cable- and fiber data on request. connector LENgth SM APC 8 9/125 G.657.A1 OM4 50/125 Bi lc-compact» LC-Compact Variable 087P6622 G657 A 087P6623 OM4 Other plug connection, cable- and fiber data on request. 10/11

19 SMAP-G2 PURE DISTRIBUTION PANEL PURE PaTCh location rack Applications For installation in 19 racks To interconnect e.g. PreconnEct PURE Trunks with patchcords in data centers ProPERtiES Maximum modularity and flexibility due to application-specific combinable 1/2 and 1/4 part front plates Very robust panel at low weight Suitable to accept all cables assembled by Rosenberger OSI 1 to 5 HU assembled with 1 HU 1/2 or 1/4 part front plates (PFP) depending on the number of fibers and coupler type Matrix numbering of the PFPs: Part numbers Single CoMPonents 19 SMAP-G2 PURE distribution panel To accept SMAP part front plates, 1 HE 2 HE 3 HE 5 HE SMAP-G2 PURE 1/4 PARt front plate BLIND PARt front plate 1 7 0 P 0 0 0 1 channels within PFPs are labeled 1 to n, PFPs within the panel are labeled 1 to n with clips Material and color: Front: steel, powder coated Body: aluminum Back planes: steel, powder coated DeliVERY FoRM Completely factory assembled without couplers. Coupler interfaces on trunk 1 7 1 P 0 0 0 1 1 7 2 P 0 0 0 1 1 7 3 P 0 0 0 1 1 7 5 P 0 0 0 1 APPlicationS High density data center infrastructures To build passive data center patch locations with highest density PROPERtiES Innovative barrier-free cable management system No rack pillars that interfere with cable routing due to cable managers being integrated into the pillars Covers of the cable managers are hinged in both directions and completely removable Several perforated feedthroughs in the side and rear walls of the cable managers for easy cable routing in the vertical and horizontal direction Professional routing of large cable volumes from patchfields and storage of cable overlength inside the vertical cable managers Particularly suitable for FO cables due to cable retainers (L-Fingers) and Finger-Slots The rounded L-Fingers ensure high bending and kinking protection for the cables even under tensile load L-Fingers do not have sharp edges and are very robust and break resistant Cables can neither be squeezed nor kinked for there is enough space within the finger-slots During work with open or removed covers the L-Fingers hold the cables back in the finger-slots Dimensions (h x d x w): 213 (46 HU) x 90 x 90 cm Material and color: steel, powder coated, Optional 19 intermediate rack to build rack rows with an uneven number of racks on request DELIVERY FORM Factory mounted on a pallet (total height with pallet and packaging = 230 cm) Incl. adjustable pedestals for on-site mounting NUMBER OF CHANNELS / FIBERS INTERFACES TYPE 19 SMAP-G2 PURE DISTRibUtion PanEL with 1/4 part front plates 12K / 24F LC-Duplex 1 7 0 P 0 1 3 0 SMAP-G2 PURE 1/2 PARt front plate BLIND part Front PLAte 1 7 0 P 0 0 0 2 NUMBER OF CHANNELS / FIBERS INTERFACES TYPE 24K / 48F LC-Duplex 1 7 0 P 0 1 7 0 PART NUMBERS 1 4 2 P 3 0 0 0 Other interfaces and numbers of fibers on request. 12/13

Maintaining PURE QUalitY: WITH ROSEnbERGER OSI cabling SERVICES THE ADVantagES FOR YOU: You ensure consistent PURE transmission quality over the long term You minimize technical downtimes by relying on experienced specialists You relieve your technical staff of work unrelated to your core business You obtain quick, expert help in an emergency You can plan with confidence on the basis of fixed, foreseeable costs PURE interfaces are guaranteed to be absolutely clean all the way to completion of trunk cable installation. But what happens when they are to be connected? The moment the seal is removed and the protective caps are taken off for connecting a patch cable, the end faces of the fibers can be soiled or damaged if the connector is improperly handled. For this reason our warranty for insertion loss in PURE connectors is valid only if patching is carried out by Rosenberger OSI Cabling Services or certified service providers. We ensure that your project stays on track in each phase of implementation: Cabling Design Advisory services Conception and planning Training and workshops Cabling Installation Installation and mounting Project management and site supervision Quality assurance THREE LEVELS TO ENSURE MAXIMUM PERfoRMance Each data center is different. The requirements relating to performance, security and availability of expert knowledge can vary widely. For this reason Rosenberger OSI BASIC: For midsize companies with small server rooms The most important standard services for basic operation Provision of a technical hotline Implementation via individual contracts The Premium Plus level gives you a choice of eleven service modules in four service areas. From channel qualification to considerably gives you three different service levels to choose from. We have developed them for you based on more than 20 years of experience in the operation of data centers. Premium: For high-performance data centers Including on-site availability of experts and technicians Extended warranty for installed Rosenberger OSI products Implementation via fixed monthly payments Premium PLUS: For high-performance data centers with maximum availability Custom warranty and service Customer-specific activities Implementation via fixed monthly payments extended warranty periods, this is the ultimate in professional cabling management for data centers. With PreconnEct PURE and Rosenberger OSI Cabling Services you can be sure of getting maximum cabling performance over the long term and finally you can ensure a reliable planning of data center cabling. Managed Cabling Basic services for data center operation Guaranteeing of resources Additional services as needed 14/15

Rosenberger OSI GmbH & Co. OHG Endorferstr. 6 D - 86167 Augsburg Telefon: +49 (0) 821-2 49 24-83 Telefax: +49 (0) 821-2 49 24-29 www.rosenberger-osi.com/pure