ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.



Similar documents
PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

How To Use A Power Supply Unit (Upu)

is then retained absolutely without interruption.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

User s Manual AURORA 1.2K/2.2K

BroadBand PowerShield. User Manual

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

HM-W536 Install Guide

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

User s Manual Before using the inverter, you need to read and save the safety instructions.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Charge Regulator SCR 12 Marine

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ST Series POWER SUPPLIES USER INSTRUCTIONS

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

YSmart Technology Co.,Ltd

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

BITMAIN. APW PSU Series User Guide

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Online UPS. PowerWalker VFI 1000R/1U

ADM1TE 5/30A DIN rail single phase two wire energy meter

Advantium 2 Plus Alarm

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Adjustment functions for both span and shift have been incorporated

MIC-WKT and MIC-WKT-IR

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

esata External Storage

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Line Interactive UPS

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Modular I/O System Analog and Digital Interface Modules

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Uninterruptible Power Supply

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Powerware 5110 UPS User s manual

MAJORSINE Power Inverter

instabus KNX / EIB System System E F G H

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

12-Volt 10-Amp Regulated Power Supply

Application Note TMA Series

Battery Power Inverters

650W Single Output Power Supply

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Self Monitoring Power Supply (BPSM)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

EGSTON Standard E2xFxWx 12W

2013 VTech Printed in China US

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

帝 聞 企 業 股 份 有 限 公 司 DEE VAN ENTERPRISE CO., LTD. SP DSL-20WA Revision: A Date: FOR AC-DC LED DRIVER MODEL NO.

Thyristor-controlled power supplies and battery chargers

Nest Learning Thermostat Installation Guide. Installation step-by-step

BB800 Off-Grid Solar System

User Manual. English. APC Smart-UPS 1000/1500 VA 100/120/230 VAC 750/1000XL VA 120/230 VAC. Tower Uninterruptible Power Supply

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Mobile Data Power Model: MDP-25

GWS250 Series Instruction Manual

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

PCS0100en Persy Control Services B.V. Netherlands

ZC-24DO CANopen I/O Module: 24 Digital Outputs

12 Volt 30 Amp Digital Solar Charge Controller

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Line Interactive UPS. PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID.

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Telephone- and leased line modem for industrial applications TD-36

Cross-beam scanning system to detect slim objects. 100 mm in

Rack mounted telephone- and leased line modem for industrial applications

USER MANUAL Online UPS 1K/2K/3K Rack

User Manual 1K/2K/3K Online UPS

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

ICON Server box installation manual Rev. 1.1

User Manual for CH-PFC76810

3000W Power Inverter

USER MANUAL Online UPS 1K/2K/3K

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

OUTPUT CABLE CONNECTIONS:

Installation and Operation Guide PD4600 Series Converter Replacement

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Transcription:

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear. EN Edition: 6 from 10.03.2014 Supercedes the edition: 5 from 16.09.2013

Features: uninterrupted supply of 13,8VDC/1A supply voltage: external transformer required 16-17VAC (e.g. AWT150) linear voltage regulator battery charging and maintenance control battery output protection against a short circuit and reverse polarity connection battery charging current 0,1A LED indication protections: SCP short-circuit protection OLP overload protection OHP overheat protection surge protection warranty 5 year from the production date CONTENTS: 1. Technical description. 1.1. General description 1.2. Block diagram 1.3. Description of components and connectors 1.4. Specifications 2. Installation. 2.1. Requirements 2.2. Installation procedure 3. Operating status indication. 3.1 LED indication 4. Operation and use 4.1. Overload or short circuit of the PSU module output 4.2. Battery-assisted operation 4.3. Maintenance 1. Technical description 1.1 General description A buffer PSU module is intended for an uninterrupted supply to alarm systems devices requiring stabilised voltage of 12V DC (+/-15%). A linear stabilizing system, which has been used in the unit, provides voltage with a lower level of noise and a quicker response to interference when compared to a switched-mode regulator. The PSU module provides voltage of U=13,8V DC with current capacity: 1. Output current 1A (without a battery) 2. Output current 0,9A + 0,1A battery charge Total current of the receivers + battery: 1A max. In case of power decay, a battery back-up is activated immediately. The battery is not protected against over-discharge (UVP). According to a given application, a proper module shall be used. CAUTION! Using the module for supplying CCTV, KD, SSWiN devices (or others of similar purpose), requires implementing of the MZN 1 protection module in the DC power output s circuit. 2

1.2. Block diagram. (Fig.1) 1.3. Description of components and connectors Table 1. Elements of the PSU pcb (see fig. 2). Element no. Fig.1. Block diagram of the PSU module. [1] P1 potentiometer, DC voltage adjustment [2] [3] [4] Description LED indication: AC LED indicating presence of AC power AUX LED indicating presence of DC output voltage Connectors: ~AC~ - AC power input (see: transformer match) +AUX- DC power output (+AUX= Vcc, -AUX=GND) Battery output of DC supply (+BAT= red, -BAT = black) [5] F BAT fuse in the battery circuit Fig. 2. The view of the PSU pcb. 3

1.4. Specifications: - electrical specifications (tab.2) - mechanical specifications (tab.3) - operating specifications (tab.4) Electrical specifications (tab. 2). Module s supply voltage 16V 17V/AC Current drawn from the transformer 1,9A max. (transformer s power 30VA min. e.g. AWT150) Power frequency 50Hz Module s power 14 W Output voltage 12,8V 13,8V DC buffer operation Output current 1A (without a battery) 0,9A + 0,1A battery charge Output voltage escalation, decrease, and keeping 70ms/70ms/16ms time Output voltage adjustment range 12,0V 14,5V Ripple voltage 5 mv p-p max. Current drawn by the PSU module systems 10 ma battery-assisted operation Battery charging current 0,3A (max.) 0,1A /24h (Iśr/24h) @ 7Ah/12V 200% 250% of PSU module power - current limiting and/or Short-circuit protection SCP fuse damage in the battery circuit (fuse-element replacement required) 110% 150% (@65 ºC 25ºC) of PSU module power - current Overload protection OLP limiting with the PTC resettable fuse, manual restart (failure requires disconnection of the DC output circuit) Battery circuit SCP and reverse polarity protections 2A- current limiting, F BAT fuse (failure requires fuse-element replacement) F BAT fuse F2A / 250V Mechanical specifications (tab. 3). Pcb dimensions 90 x 55 x 72 (WxLxH) [mm] (+/- 2) Fixing Dowel pins x 4 (PCB fi=4,2 mm) Net/gross weight 0,12kg/0,15kg Connectors Outputs : Ф0,41 1,63 (AWG 26-14) BAT battery outputs: 6,3F-2,5, 30mm Operating specifications (tab.4). Operating temperature Storage temperature Relative humidity Vibrations during operation Impulse waves during operation Direct insolation Vibrations and impulse waves during transport -10ºC...+40ºC -20ºC...+60ºC 20%...90%, without condensation unacceptable unacceptable unacceptable PN-83/T-42106 2. Installation. 2.1 Requirements The buffer PSU module is to be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a given country) for 230V/AC interference and low-voltage installations. The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative humidity (RH=90% maximum, without condensation) and temperature from -10 C to +40 C. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the enclosure. 1. Output current 1A (without a battery) 2. Output current 0,9A + 0,1A battery charge Total current of the receivers + battery: 1A max. As the PSU module is designed for a continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about the method of unplugging (most frequently through separating and assigning an appropriate fuse in the fuse-box). The electrical system shall follow valid standards and regulations. 4

The device should be installed in the metallic enclosure (cabinet). In order to meet the UE requirements, the rules concerning: supply, development and shielding ought to be followed- accordingly to the application power supply 16-17VAC with galvanic isolation (transformer insulation). The power of the transformer shall be matched in accordance with the following chart S=f(I) (chart1). Chart.1. The dependence between the transformer s power - S and the output power of the PSU module - Io. 2.2 Installation procedure Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 1. Mount the enclosure (cabinet) and lay the cables. 2. Mount the module on dowel pins (the dowel pins shall be fixed prior to the installation of the enclosure/cabinet). 3. Deliver the output voltage from the AC transformer to the ~AC~ terminals. 4. Connect the receivers cables to the +AUX, -AUX terminals of the terminal block on the PSU module s board. 5. Activate the ~230V/AC supply (the AC red diode and AUX green diode should be permanently illuminated). 6. Check the output voltage (the PSU module voltage without load should amount to 13,6V 13,9V, during battery charging 12V-13,8V). If the value of the voltage requires adjustment, it should be set by the P1 potentiometer, monitoring the voltage at the AUX output of the PSU module. 7. Connect the battery in accordance with the signs: +BAT red to plus, -BAT black to minus. 8. Once the tests and operation control have been completed, the enclosure/cabinet can be locked. 3. Operating status indication. 3.1 LED indication The PSU module is equipped with two diodes indicating operating status: AC- red diode: under normal status (AC supply) the diode is permanently illuminated. The absence of AC supply is indicated by the AC diode going out. AUX- green diode: indicates the DC supply status at the output of the PSU module. Under normal status, the diode is permanently illuminated. In case of a short circuit or overload the diode is off. 4. Operation and use. 4.1 Overload or short circuit of the PSU module output The AUX output of the PSU module is equipped with the PTC polyswitch-assisted protection. If the load of the PSU module exceeds 1,5A (load 110% 150% @25ºC of the PSU module power), the output voltage is automatically cut off and indicated by the green diode going out. To restore the output power, cut off the output load for approximately 1 minute.in case of a short-circuit in the AUX, BAT output, (load 200% 250% of the PSU module power) or reverse battery connection, the F1 fuse in the battery circuit becomes permanently damaged and the restoration of the voltage at the BAT output requires the replacement of the fuse. 4.2 Battery-assisted operation. In case of the main power outage, the device is immediately switched into a battery-assisted operation. In order to run the module from the battery only, connect the BAT connectors in accordance with the signs: + BAT red to plus and, - BAT black to 'minus of the battery. 5

The power supply module is not equipped with a discharged battery disconnection system (UVP). 4.3. Maintenance. Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply network. The PSU module does not require performing any specific maintenance measures. However, in case of a thick dust layer, clean the PSU only with compressed air. In case of a fuse exchange, use the replacement of the same parameters. WEEE MARK According to the EU WEE Directive It is required not to dispose of electric or electronic waste as unsorted municipal waste and to collect such WEEE separately. CAUTION! The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the applicable law. THE GENERAL WARRANTY CONDITIONS 1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a five-years warranty for the equipment, counted from the device s production date. 2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the manufacturer s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such defects have been reported within the warranty period (item 1). 3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the manufacturer. 4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect. 5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenienve, however not later that within 14 days from the delivery to the service centre of the manufacturer. 6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant. 7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively. 8. The warranty does not cover the defects of the equipment, resulting from: - reasons beyond the manufacturer's control, - mechanical damage, - improper storage and transport, - use that violates the operation manual or equipment s intended use - fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents, - improper installation and configuration (in defiance with the manual), 9. The warranty is void in any of the following circumstances: - construction changes - repairs carried out by any unauthorized service center - damage or removal of warranty labels - modifications of the serial number 10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the wholesale prices suggested by the manufacturer on the day of purchase. 11. The manufacturer takes no reponsibility for the defects that result from: - the damaging, malfunctioning or inability to operate the equipment - defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the recommendations and requirements contained in the manual, or the use of the equipment. Pulsar K.Bogusz Sp.j. Siedlec 150, 32-744 Łapczyca, Polska Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 e-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl 6