DATA SHEET. Capnography option. www.airliquidemedicalsystems.com. November 2013 V2.2



Similar documents
MEDICAL SYSTEMS. Monnal T60. Touch and Breathe.

Boaray 700 Anesthesia Machine

Oxylog 3000 plus Emergency & Transport Ventilation

Hospital Respiratory Care Catalogue

«The compact and mobile testing device for ventilators.»

The centrepiece of a complete anaesthesia workstation

Impact Uni-Vent 754 Portable Ventilator

Table of contents. Exercise 1 Passive exhalation port 13. Exercise 2 Active exhalation valve 15

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

Impact Uni-Vent 750 Portable Ventilator

VELA. ventilator user guide. Critical care ventilation

Dräger Evita Infinity V500 ventilator ICU Ventilation and Respiratory Monitoring

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

Aliseo Anesthesia system

MEDUMAT Easy CPR The Guiding Emergency Ventilator

Dräger Babylog VN500 Neonatal Open Care

Anesthesia Solutions. Prima SP2 Anesthesia Systems. The Future of Anesthesia. Partnership for Life

Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n

Vivo 50/60 PC Software Help (english), version Introduction. 3. Dialogs. 7. Year data view. 8. Alarm view. 2. User interface. 9.

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?

The Anesthesia Ventilator

Puritan Bennett 840 Ventilator User s Pocket Guide. Puritan Bennett 840 Ventilator Pocket Guide

FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 60 Ventilator. Operator's Manual

Inspiration Series Ventilator Technical Manual

Mechanical Ventilation for Dummies Keep It Simple Stupid

Ventilators/Transport*

BIPAP Synchrony TM AVAPS

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

Carina Pocket Guide Software version 3.n. The Carina Pocket Guide is not a replacement or substitute for the Instructions for Use.

Your personal anesthesia assistant DRÄGER PRIMUS

Puritan Bennett 980 Ventilator Patient Setup Quick Reference Guide

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

FLIGHT MEDICAL INNOVATIONS LTD. FLIGHT 50 Ventilator. Service Manual. DOC-0004 Rev B. Sep 2012

The intelligent solution for the mobile ICU

Nurses and Respiratory Therapists Working Together for Safe Alarm Systems Management

A ANESTHESIA SYSTEMS. intuitive effortless precise

AutoFlow The Oxylog 3000 plus incorporates the benefits of pressure controlled ventilation into volume controlled ventilation

3100B Clinical Training Program. 3100B HFOV VIASYS Healthcare

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

The Anesthesia Ventilator

The Puritan Bennett 980 Ventilator

Aespire View. User s Reference Manual. Software Revision 6.X

Home Ventilator Breath of Life Home Medical Equipment and Respiratory Services

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

DEBSON TM2 OXYGEN THERAPY FLOWMETERS WITH PRE ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION. English version 11/ 2 010

From AARC Protocol Committee; Subcommittee Adult Critical Care Version 1.0a (Sept., 2003), Subcommittee Chair, Susan P. Pilbeam

Oxygenation and Oxygen Therapy Michael Billow, D.O.

Operator s Instruction Manual

PORTABLE, SELF-CONTAINED VENTILATION SYSTEM

Fabius GS. Inhalation Anesthesia Machine Software 3.n Operating Instructions. Because you care

Effective Treatment for Obstructive Sleep Apnoea

Technical Service Manual Babylog 8000/8000SC/8000 plus Intensive Care Ventilator

MECHINICAL VENTILATION S. Kache, MD

T0118 T2118 T3118. Instruction Manual

Auto Flow 20 Questions 20 Answers. Joseph Fitzgerald

D A cost effective monitor that meets your clinical needs VISTA 120

Operating Manual. Newport Medical Instruments, Inc. NEWPORT HT50 VENTILATOR. OPRHT50NA Rev. B September Exclusively Distributed by:

Home Healthcare Respiratory Catalogue

REGTRONIC OPERATING INSTRUCTIONS

Dräger Globe-Trotter GT5400 Neonatal Transport

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Common Ventilator Management Issues

Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves

2000 Respironics, Inc. All rights reserved.

Puritan Bennett. Achieva Ventilators. with Flow Acceleration and Apnea Back Up. Clinician s Manual

D Non-Invasive Ventilation (NIV) with the Oxylog 2000 plus and Oxylog 3000 plus

Critical Care Therapy and Respiratory Care Section

Rackmount Intelligent Pressure Scanners

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

POCKET GUIDE. NAVA and NIV NAVA in neonatal settings

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

ServoCare PRODUCTS AND ACCESSORIES CATALOG ISSUED OCTOBER 2004 CRITICAL CARE

Airway Pressure Release Ventilation

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Artificial Ventilation Theory into practice

RRV934. Multi-controller. Synco living

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Nasal-Aire II Critical Care Single-use CPAP interface by InnoMed The comfortable, economical solution to non-invasive ventilation!

For over 40 years, the leader in. nitrous oxide. equipment technology.

The PACE5000 Modular Pressure Controller/Indicator

Lockout Specification BW Clip Maintenance-free single gas detector

Two Steps forward in Ventilation. Ernst Bahns. Because you care

Vista 120 Patient Monitor

5000V Graphical Megohmmeter Model 5070

REGSON TM2 OXYGEN-THERAPY PRESSURE REGULATORS WITH FLOWMETER WITH PRE-ADJUSTED FLOWRATES MORE SAFETY GAS FLOW BETWEEN TWO POSITION

API Marine. BMS Presentation. Ballast Measurement Systems

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Datex-Ohmeda Critical Care Monitor

T Substation Maintenance and Commissioning Test Equipment

Typical Aluminum GFM Mass Flow Meter

Vela Ventilator Diamond Series. Operator s Manual

Heating Controller. Building Technologies HVAC Products

Type-D EEG System for Regular EEG Clinic

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

Sleep Therapy I Ventilation I Patient Interface. Sleep Therapy. Sleep therapy solutions for every patient

Transcription:

November 2013 V2.2 DATA SHEET www.airliquidemedicalsystems.com

[1] Monnal T75 (CO 2 )/ Air Liquide Medical Systems APPLICATION AREA OPERATING CONDITIONS Application: Patient categories: Weight: Intensive care respirator designed for resuscitation, intensive care and the postoperative room Adult, Child and Infant. 3 to 250 kg Operating Temperature: Relative humidity: Atmospheric pressure: +10 to +40 C (+50 to +104 F) 0 to 90 % (at 40 C without condensation) 700 (3075 mètres) to 1060 mbar Altitude effect compensation STANDARDS AND DIRECTIVES STORAGE CONDITIONS CE Mark: CE 0459. The device complies with the European requirements in the Directive 93/42/EEC concerning medical devices. Storage temperature: Storage relative humidity: -20 to +70 C (-4 to +158 F) 0 to 90 % (at 40 C without condensation) Medical classification: Standards: Class IIb, according to Directive 93/42/CEE. ISO 14971 CEI 60601-1 CEI 60601-2-12 Storage atmospheric pressure: 500 (5550 meters) to 1060 mbar Electromagnetic compatibility (EMC): Complying with CEI 60601-1-2 (2001) First launch: France: end of 2008 Other countries: please contact us Available languages: French, English, Italian, German, Russian, Spanish, Lithuania, Polish, Czech,Portuguese, Chinese, Japanese Other language: please contact us PHYSICAL SPECIFICATIONS Size: Ventilator with trolley: H 35 x W 30 x D 40 cm H 135 x W 55 x D 60 cm Weight: Noise level: 16 kg - Ventilator 31,8 kg - Ventilator + trolley 48 db (A) at 1m

[2] Monnal T75 (CO 2 )/ Air Liquide Medical Systems POWER SUPPLY Power supply: 100-240 V AC ± 5 % PNEUMATIC SUPPLY Oxygen pneumatic supply Frequency: Electric power consumed: 50 60 Hz 250 VA High pressure: 2.8 6 bar / 280 600 kpa / 40 86 psi Operating possible starting from 1.5 bar Electric class: Type: I B Connection standards available: NF, NIST, DISS For other standards, please contact us Connection standards available: EU, AFS, JP, US, AR, BR Please contact us for more information concerning other standards Low pressure: Air pneumatic supply 0 1.5 bar / 0 150 kpa / 0 21 psi Continuous external supply: 20 to 30 V DC Turbine peak flow: 200 l/mn at Patm EXTERNAL BATTERY: If no mains are available, switch to external battery Ambiant air inlet: Equipped with HEPA filter Monnal Clean In (High Efficiency Particulate Air Filter) Type: Rechargeable, NiMH, 24V, 2x4500 mah PATIENT SYSTEM GAS CONNECTOR Autonomy: Charge time: 2,5 to 3 hours in standard ventilation 12 hours Inspiratory breathing tube connector: 22 mm male Interval between two recharges: It is advised to perform one complete discharge cycle every 6 months INTERNAL BATTERY: If neither the mains nor the external source is available, switch to internal battery Expiratory breathing tube connector: 22 mm male SCREEN Type: Rechargeable, NiMH, 24V, 2x4500 mah Type: Flat color touch screen TFT-LCD Module Autonomy: 2,5 to 3 hours in standard ventilation Technology: Resistive analogical technology Charge time: 12 hours Size: 10.4 inches Interval between two recharges: It is advised to perform one complete discharge cycle every 6 months Resolution: 640 x 480 pixels

[3] Monnal T75 (CO 2 )/ Air Liquide Medical Systems PNEUMATIC SPECIFICATIONS MODES INVASIVE VENTILATION Method of triggering: Flow and pressure VCV PCV Volume Controlled Ventilation or Assist volume controlled ventilation Pressure Controlled Ventilation or Assist pressure controlled ventilation Max. Operating pressure: 90 cmh 2 O PRVC SIMV Pressure Regulated Volume Controlled ventilation Synchronized Intermittent Mandatory Ventilation Bias flow: 3 L/min (flow by) PSIMV Pressure Synchronized Intermittent Mandatory Ventilation Max. Inspiratory peak flow: 180 L/min (regarding supply pressures) PSV CPAP PS-Pro Spontaneous ventilation with Pressure Support and PEEP Continuous Positive Airway Pressure Spontaneous ventilation with Pressure Support, PEEP and variable frequencies INSPIRATORY CHANNEL APRV Duo-Levels Airway Pressure Release Ventilation Alternation between two levels of CPAP Pressure drop: Max. 4 cm H 2 O at a flow rate of 1L/s (without filter) Safety ventilation Apnea ventilation (V T, RR and T apnea can be adjusted, constant flow rate, Ti.Ttot 33%) Gaz supplier system: Turbine and proportional solenoid valve managed by microprocessor MODES NON INVASIVE VENTILATION Inspiratory flow range: 0 to 3,3 L/s PSV-VNI CPAP Non-invasive spontaneous ventilation with Pressure Support and PEEP Continuous Positive Airway Pressure EXPIRATORY CHANNEL APRV Duo-Levels Airway Pressure Release Ventilation Alternation between two levels of CPAP Pressure drop: Expiratory flow range: Max. 3 cm H 2 O at a flow rate of 1L/s 0 to 3,3 L/s OXYGENOTHERAPY Flow Adult: 2 to 80 L/min Child and Infant: 2 to 60 L/min FiO2 21% to 100% This function requires specific nasal cannula and use a heating humidifier.

[4] Monnal T75 (CO 2 )/ Air Liquide Medical Systems PARAMETER SETTINGS PARAMETER SETTINGS (NEXT) SETTINGS RANGE: SETTINGS RANGE: Inspiratory tidal volume (V T ): 20 to 2000 ml Inspiratory plateau (Tplat): 0 to 60 % of TI Adult: 0 to 60 % of TI Adult: 100 to 2000 ml Child: 0 to 40 % of TI Child: 50 to 500 ml Infant: 0 to 40 % of TI Infant: 20 to 75 ml Inspiratory ratio (TI/Ttot): 3 to 80 % Respiratory Rate (RR): 4 to 120 Bpm Adult: 3 to 80 % Adult: 4 to 80 Bpm Child: 5 to 60 % Child: 5 to 120 Bpm Infant: 5 to 60 % Infant: 10 to 120 Bpm Inspiratory time (I/E): 1/0,3 to 1/19 SIMV respiratory rate (SIMV RR): 4 to 120 Bpm Adult: 1/0,3 to 1/19 Child: 1/0,7 to 1/19 Adult: 4 to 80 Bpm Child: 5 to 120 Bpm Infant: 1/0,7 to 1/19 Infant: 10 to 120 Bpm Inspiratory time (Ti): 0,2 to 10 s Minimum frequency: 1 to 100 Bpm Adult: 0,2 to 10 s Adult: 4 to 80 Bpm Child: 5 to 100 Bpm Child: 0,2 to 8 s Infant: 0,2 to 3 s Apnea time: Adjustable VCV mode Infant: 10 to 100 Bpm Max. inspiratory time in spontaneous modes (TI max.): 0,2 to 5 s Adult: 15 to 60 s Child: 4 to 60 s Infant: 2 to 30 s Adult: 0,3 to 5 s Child: 0,3 to 5 s Infant: 0,2 to 2,5 s

[5] Monnal T75 (CO 2 )/ Air Liquide Medical Systems PARAMETER SETTINGS (NEXT) PARAMETERS SETTINGS: SPECIAL FEATURES Positive End of Expiration Pressure (PEEP): Pressure Support (PS): SETTING RANGE: 0 to 50 cmh 2 O 2 to 40 cmh 2 O NON INVASIVE VENTILATION: Positive End of Expiration Pressure (PEEP): Pressure Support (PS): 0 to 15 cmh 2 O 2 to 25 cmh 2 O Insufflation Pressure (PI): 2 to 99 cmh 2 0 Max. airways pressure: 90 cmh 2 0 Inspiratory slope: Flow rate shape: 20 to 200 cmh 2 O / s Constant, decelerated O 2 concentration (FiO 2 ): 21 to 100 % Inspiratory flow trigger: 1 to 10 L/min OFF position available in VCV, PCV and PRCV modes Low VMe alarm: PRCV MODE: Target Tidal volume: Insufflation pressure (PI): Max. Insufflation pressure (PI max): OFF position available OFF to maximum of each patient category AUTO, 2 to 99 cmh 2 O 2 to 99 cmh 2 O Inspiratory pressure trigger: Always activated and automatically set in function of the flow trigger setting PS-PRO MODE: Support frequency (RRsupport) Adult: 4 to 99 Bpm Expiratory trigger: 0 (OFF) to 90 % of inspiratory peak flow Child: 5 to 120 Bpm Infant: 5 to 120 Bpm Adult: 5 to 90% Pressure Support (PS) : AUTO, 2 to 40 cmh 2 O Inspiratory plateau: Expiratory plateau: Manual Breath Child: 0 to 90% 0 to 15 s 0 to 15 s 0 to 15 s Max. Insufflation pressure (PI max): Target Tidal volume : 2 to 99 cmh 2 O OFF to maximum of each patient category Sigh frequency: 1 sigh every 9 to 200 cycles O2 : ASPIRATION INTELLIGENTE Sigh Tidal volume: 1 to 2 per V T Durée de pré-oxygénation 30 to 900 s Sigh insufflation pressure: 1 to 2 per PI Durée de post-oxygénation 30 to 300 s Infant: 0 to 90% Cible FiO2 21% to 100% O2: INTELLIGENT SUCTION Pre-oxygénation time: 30 to 900 s Post-oxygénation time: 30 to 300 s FiO2 target 21% to 100% TC: TUBE COMPENSATION Applicable on: Pressure modes only Compensation level: 0 to 100% Tube type: Endotracheal or tracheostomy Tube diameter: 2.5 to 11 mm

[6] Monnal T75 (CO 2 )/ Air Liquide Medical Systems MONITORING MEASURED MEASURE RANGE: TREND VALUE*: Expired Minute Volume (VMe) 0 to 99 L/min Expired Tidal Volume(Vte) 0 to 5000 ml Insufflated Tidal Volume (VTi) 0 to 5000 ml Respiratory Rate (RR) 0 to 120 Bpm Peak Airways pressure (Ppeak) 0 to 120 cmh 2 O Positive End of Expiration Pressure (PEEP): 0 to 99 cmh 2 O Plateau pressure (Pplat) ** 0 to 99 cmh 2 O FiO2 15 to 100% Mean pressure 0 to 99 cmh 2 O Ti / Ttot 0 to 99% RR / Vte 0 to 5000 pm/l MVe Spont 0 to 99 L/min RR Spont 0 to 120 Bpm Insp Peak Flow ** 0 to 200 L/min Exp Peak Flow 0 to 200 L/min Leak Flow (in VNI) 0 to 150 L/min Spontaneous ratio -- to 100 Leak ratio -- to 100 Auto-PEEP ** 0 to 99 cmh 2 O Rstat ** Cstat ** 0 to 500 cmh 2 O/(L/s) 0 to 150 ml/ cmh 2 O Rdyn ** 0 to 500 cmh 2 O/(L/s) Cdyn** 0 to 150 ml/ cmh 2 O P0.1 ** 0 to 20 cmh 2 O MONITORING (NEXT) MEASURED Negative Inspiratory Force (NIF) Respiratory effort (inspiratory) (WOB) LOOPS AND WAVEFORMS PRESENTATION Real-time curves: Loop curves: Pressure curve Flow curve Volume curve CO 2 curve (if CO 2 option is activated) Pressure / Volume Volume / Flow Flow / Pressure CO 2 / Volume (if CO 2 option is activated) CAPNOGRAPHY (OPTION) MEASURED MEASURE RANGE: TREND VALUE*: Fraction of CO2 at the end of expiration (etco2, %) 0 15 CO2 pressure at the end of expiration (etco2, mmhg) 0-100 CO2 pressure at the end of expiration (etco2, kpa) 0 15 CO2 minute volume (VMCO2, ml/min) Alveolar minute volume (Vmalv, L/min) Ratio of airway dead space to tidal volume (Vdaw/Vt, %) Airway dead space volume (Vdaw, ml) MEASURE RANGE: 0 to 30 cmh 2 O 0 to 2 Joule/L 0-9999 No 0 99 No 0 100 No 0 5000 TREND VALUE*: No * Stored trend values for up to 80 hours ** Only in Invasive Ventilation Slope of the volumetric capnogram on the alveolar plateau (SlopeCO2, %CO2/L) 0 99 No

[7] Monnal T75 (CO 2 )/ Air Liquide Medical Systems ALARMS SETTINGS ALARMS SYSTEMS Ppeak high Ppeak low Pplat high RR low 10 to 100 cmh 2 O 1 to 85 cmh 2 O OFF, 1 to 50 cmh 2 O Adult: 1 to 70 Bpm Child: 1 to 110 Bpm Visual alarms classified by priority: Sound alarms classified by priority: 3 priority levels with specific colors 1 information level 3 priority levels with specific melodies Infant: 1 to 110 Bpm Technical alarms: Categorized by severity RR high Vti low Adult: 11 to 80 Bpm Child: 11 to 120 Bpm Infant: 11 to 120 Bpm Adult: OFF to 2900 ml Supply alarms: O 2 supply failure Switch over to external battery Switch over to internal battery Internal battery power low Internal battery exhausted Child: OFF to 1900 ml Internal battery absent Vti high Infant: OFF to 500 ml Adult: 100 to 3000 ml Child: 100 to 2000 ml Automatic thresholds: Alarm indicating total loss of electrical power Direct access key Infant: 100 to 800 ml Sound inhibition: 2 minutes Vte low Adult: OFF to 2000 ml Apnea ventilation: Adjustable VCV mode Vte high Child: OFF to 2000 ml Infant: OFF to 500 ml Adult: 10 to 3000 ml Child: 10 to 3000 ml Infant: 10 to 800 ml Non-adjustable patient alarms: Disconnection PEEP > PEEP set-point + 5 cmh 2 O Active patient. Increase inspiratory flow rate VMe low VMe high 0,1 to 39 L/mn Adult: 1,5 to 40 L/mn EVENT HISTORY Child: 1,5 to 40 L/mn Infant: 1 to 40 L/mn FiO 2 low 18 to 95 % FiO 2 high 23 to 100 % Alarms history: 200 last triggered alarms recorded Technical messages with error codes ALARMS SETTINGS: SPECIAL FEATURES OF NIV ACCESSORIES Trolley (4-wheel base) VMe low VMe high VTi OFF to 39 L/mn Adult: 1,5 to 60 L/min Child: 1,1 to 60 L/min Infant: 1 to 40 L/min Low and High not measured Side tablet with pincers and hook Wall tablet Monnal T75 cover External Battery Others (please refer to catalogue)

[8] Monnal T75 (CO 2 )/ Air Liquide Medical Systems CONFIGURATION CLEANING AND STERILIZATION Selection of ventilation mode: Enabled, Disabled (except VCV always enabled) Autoclavable: Reusable expiratory valve Patient circuit Alarms: Save alarms current settings Reusable spirometry sensor Settings: Save current ventilation settings in the ventilation mode used Single use: Single use expiratory valve Alarm volume setting: 25% to 100% of custom alarm Patient circuit Single use spirometry sensor Min. frequency: Setting in VCV mode: Enabled, Disabled (only in PS and NIV-PS) Ti, Flow, TI/Ttot or I/E Turbine inlet: «Monnal Clean in» filter (quaterly inspection) Setting in PCV / PRCV mode: Ti, TI/Ttot or I/E MAINTENANCE COMMUNICATION / INTERFACE Serial port: RS 232 port (X 2) Periodic maintenance: Annual, performance check OTP: Open Taema Protocol Video output: Screen report to external monitor. BOW MEDICAL Interface: Communication with DIANE anaesthesia sheet DATACAPTOR: Capsuleteck CLINISOFT interface: Communication with the GE data collection software

Contact Air Liquide Medical Systems Parc de Haute Technologie 6, rue Georges Besse 92 182 ANTONY CEDEX FRANCE Tél. : +33 (0)1 40 96 66 00 Fax : +33 (0)1 40 96 67 00 Customer Service Credit Photo Le Square Air Liquide Medical Systems reserves the right to modify the design and the specifications contained herein without prior notice. Air Liquide Healthcare is a world leader in medical gases, home healthcare, hygiene products and healthcare specialty ingredients. It aims to provide customers in the continuum of care from hospital to home with medical products, specialty ingredients and services that contribute to protecting vulnerable lives.