Proof of Concept - Solar Energy DG Distribution Warehouse



Similar documents
Solar Power at Vernier Software & Technology

Additional Solar System Information and Resources

THE ROOFPOINT ENERGY AND CARBON CALCULATOR A NEW MODELING TOOL FOR ROOFING PROFESSIONALS

SOLAR PV INFORMATION. January, 2015

3.36 kw Solar PV Kit Pricing

Virtual Solar Tour 2014

Harnessing Solar Energy for Broiler Production

Solar Photovoltaic Frequently Asked Questions

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Simplified M&V Guidelines for Lighting Efficiency Measures

Summary of Electric Power Research Institute (EPRI) Report on Residential Off-Grid System Economics

Running the Electric Meter Backwards: Real-Life Experience with a Residential Solar Power System

Lighting Control in the Office Space

PENNSYLVANIA GREEN ENERGY LOAN FUND

ALL STAR ELECTRIC COMPANY 10,000 Trumbull SE, Suite #F Albuquerque, NM (505) voice & fax NM License

Replacing Fuel With Solar Energy

Energy and Energy Efficient Alternates Study

FDA Building One. R. Andy Pahwa. Faculty Advisor: Jim Freihaut/Dustin Eplee

CUTES Solar Power System

Case Study -Sandy Grove Middle School First Net Positive Energy P3 School In North Carolina

Solar Energy Systems. Matt Aldeman Senior Energy Analyst Center for Renewable Energy Illinois State University

The time is right for Solar!

LIGHTING and LIGHTING SYSTEMS

Sustainable Office Design (SOD) is different than existing programs STEP 1: STEP 2: STEP 3: STEP 4:

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings

Information sheet. 1) Solar Panels - Basics. 2) Solar Panels Functionality

GUIDE TO NET ENERGY METERING.

National Electrical Manufacturers Association Guidance on Energy Policy Act Commercial Building s Tax Deduction Certification Letters

NBF. Electrical. WHY GO SOLAR? NBF ELECTRICAL EXPLAINS WHY

Solar and Wind Energy for Greenhouses. A.J. Both 1 and Tom Manning 2

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Photovoltaic Industry Technologies, Markets & Trends

CA Title Lighting and Receptacle Control Requirements for Commercial Buildings. Michael Jouaneh, CEM, LEED AP July 1, 2014

SOLAR FARM KITS Off grid/battery backup

Rules of Thumb Energy Efficiency in Buildings

Los Angeles Community College District

Mailing Address 4650 Adohr Ln. Camarillo, CA Year Financial Analysis. $1,051 / mo (avg) Cost Breakdown. System Description

Everything you wanted to know (in simple language) about

Solar Energy for the Homeowner. Glen Salas

Greg Eikam Director of Facilities. University of California, Irvine Healthcare

Trinchero Family Estates Building: Operation User s Guide

Auburn University s Solar Photovoltaic Array Tilt Angle and Tracking Performance Experiment

ANALYSIS 2: Photovoltaic Glass Replacement

Q Utility Rebate Report. Houston, TX

Solar technology. A guide to solar power at utility scale. in Africa

Solar*Rewards Frequently Asked Questions

Solar power system installation for homes & businesses

High Bay Occupancy Sensor Selection Guide

NOTICE OF INTENT Department of Revenue Policy Services Division. Income Tax Credits for Wind or Solar Energy Systems (LAC: 61:I.

Energy Efficiency Market Transformation Opportunities for Texas

Code Compliance Commercial Application Guide

The Sun-Root System. Introducing the Latest Achievement in Sustainable Technology. Green Roof Technology 1. Sun-Root System. Green Roof Service, LLC

Financing Solar Energy Projects: The Role of Local Government

Solar for Homeowners. Bear Valley Solar Initiative (BVSI) Laura Williams, Project Manager. February,

Smart Cities Smart Streetlights Panel Discussion. September 23, 2014

Corona Department of Water & Power (DWP) Solar Partnership Program Guidelines and Application

2016 Santee Cooper Solar Home & Solar Share Home Program Manual

NY Solar Summit 2014 Case Studies - Strategic Solar Growth

Coslight Hybrid Power System with Solar

BUILDING INTEGRATED PHOTOVOLTAICS

Key words: Photovoltaic modules, insolation, charge controller, system sizing, continuous wattage, surge wattage.

Rooftop Revenues. How Your Business Can Profit from Solar Energy.

User Manual of Grid Tie Inverter with Limiter

Request for Proposals for Photovoltaic System Installation

Wind and Solar Renewable Energy Applications

The SunMizer SRS Advantage. Copyright 2013 Xandex Inc.

Ontario Electrical Safety Code 25 th Edition/ 2012

Gross/Active PV Surface Area: ,40 / ,29 m². Energy Produced by PV Array (AC):

Calculating Solar Energy System Performance & Payback

Solar Interconnections

Massachusetts PV and SHW Program Update Elizabeth Kennedy Program Director Massachusetts Clean Energy Center

Business Energy Rebates Application

Advanced solar power generation... Corporate Sales:

Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'

Energy Savings through Solar Energy for Municipalities

Financial Analysis of Solar Photovoltaic Power plant in India

Strategies and Incentives for Retrofitting Commercial Buildings to Reduce Energy Consumption

EFFICIENT EAST-WEST ORIENTATED PV SYSTEMS WITH ONE MPP TRACKER

Free electricity for your home, offices or factory with solar PV panels

Control of a Hybrid Energy System

Hybrid and Off grid Systems Princeton Power Systems Inverter Technology Ken McCauley and Alan Cohen Princeton Power Systems


Solar Energy. Airports Going Green Aimee Fenlon

Thanks for your interest in going solar at one of our group off-site solar farms.

FREQUENTLY ASKED QUESTIONS

Deep Energy Savings in Existing Buildings

SolarFlair Energy Inc. 190 Pleasant St, Ashland, MA

Industrial Green Building Retrofit 101 Opportunities and Challenges. Light Industrial Green Building Retrofits. Why Green Retrofit?

... TABLE OF CONTENTS

By: Crystal Warren IMPLEMENTATION OF SOLAR PANELS ON COMMERCIAL PROPERTIES AND THE COST-BASED INCENTIVES

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted.

How To Design A Sustainable Roofing

Solar Panels and the Smart Grid

Interpreting Solar Power Graphs Demonstration Activity

Solar Photovoltaic (PV) Systems

A SOLAR GUIDE - EVERYTHING YOU NEED TO KNOW

Chester Group Solar Farm Panel Purchase and License Quote

TECHNICAL GUIDE A GUIDE FOR THE SELECTION OF ENERGY EFFICIENT TECHNOLOGIES

Solar for Businesses. Getting Started with Solar. Laura Williams, Renewables Project Manager. June 10, 2015

BUSINESS CASE INSTALLATION OF SOLAR PV ON COUNCIL BUILDINGS CITY OF BELMONT 2014

Transcription:

Proof of Concept - Solar Energy DG Distribution Warehouse This is for a proof of concept for a high efficiency renewable energy lighting system at a Distribution Center in Rochester, NY. This LEED gold-rated facility is equipped with a lighting system that utilizes DC fluorescent ballasts, roof-integrated solar panels, occupancy sensors, and daylight sensors for the highest possible efficiency. The building, including the innovative lighting design, was designed by William McDonough and Partners of Charlottesville, VA. Facility: The facility has 6,600 sq ft of office space and 33,000 sq ft of warehouse. The warehouse roof is equipped with skylights and 21kW of solar panels bonded to the roof material (SR2001 amorphous panels by Solar Integrated Technologies). A canopy in the office area is equipped with 2.1kW of Sharp panels. Figure 1 - Sharp Panels - Canopy The power from the solar panels is distributed in three ways: 2.2 kw is dedicated to the lighting in the office, 11.5 kw powers the lights in the warehouse, 11.5 kw is not needed by the lighting system so it is inverted to AC and used elsewhere in the building or sold back to the utility. 1

The entire system consists of 35 NPS-1000 Power Gateways. These devices take all of the available power from the solar panels and send it directly to the lighting without significant losses. Additional power, when needed at night or on cloudy days, is taken from the grid. In the office, 6 NPS-1000 s power 198 T-8, four foot fluorescent lamps, illuminating most areas at 1.1 watts per square foot. Each of the fixtures is equipped with one high efficiency DC ballast for every two lamps. Most of the fixtures are controlled by a combination of manual switches, daylight sensors, and occupancy sensors in 13 zones. Figure 2 - Office Lighting Figure 3 - Warehouse Lighting In the warehouse area 29 NPS-1000 s power 158 6-lamp T-8 fixtures. These fixtures have a low (2 lamps on), medium (4 lamps on), and high (all 6 lamps on) setting so that they can be dimmed by 3 daylight sensors and 30 occupancy sensors located throughout the area. The goal of the control architecture is to maintain a lighting level of.74 watts per square foot, using daylight when available, whenever the area is occupied. The logic of the lighting system is designed for optimum efficiency. Sources of light and power are prioritized such that: First, daylight from the skylights is used. Second, if day-lighting is not sufficient and the area is occupied then power from the solar panels is added. Third, if daylight and solar power is not enough then the additional power required is taken from the grid. 2

Figure 4 - SensorSwitch Daylight, Occupancy Sensors A number of factors contribute to the value of this system; Using the electricity generated by the solar panels to power the lighting eliminated significant inverter losses and improved efficiency by as much as 20%. The low voltage control capability of the DC ballasts enabled the innovative control system to be installed easily, without additional AC wiring. Roof-Integrated solar panels reduced installation costs and allow the cost of the roof to be recovered using a 5-year accelerated depreciation formula. Performance Occupancy and Daylight Sensors Figure 5 - Occupancy Sensors The Red line shows the lighting profile of the building without load shedding. Most of the lighting comes on at 3AM. All lights are turned on from 6AM to 6PM. The Blue line shows the lighting load with the occupancy and daylight sensors controlling the lighting. Between March and Mid-June 2005 between 20% and 30% savings have been achieved due to the controls. 3

Performance of the Power Gateway In the chart below, power from the DC solar system is shown, along with the net utility power consumed by the lighting. Around noon, all of the power for the lighting is being supplied by the solar array. An important key here is that the efficiency of solar to lighting is nearly 100%. Only minimal wiring losses are encountered when no grid power is used. Figure 6 - Power Consumption by DC Lighting System Monitoring Web Based The Web-based Data Collection and Monitoring system provides a web-based display of power generated, power used, weather, and more. Available through the NextekPower.com website in a password protected directory, this system not only displays performance data, but also identifies anomalies in the system such as burned-out lamps, and sensors that are not operating properly. In June, remote analysis identified an opportunity to improve the settings of the occupancy sensors. The new settings will generate additional savings in coming months. Value The Green DC or Green Distribution Center has been a successful effort on this distribution center's part to bring more sustainable business practices into its facilities. The pay back on their investment at the Rochester location, after rebates and accelerated depreciation is approximately 12.6 years, as shown in the table below. The remaining system output will produce energy for 7.5 years, producing $60,000 in value at today s rates in Rochester. It is important to note that, in areas where the avoided cost of peak 4

power is higher than $0.10 per kwh, this Return of Investment can drop to under 6 years, meaning that, in those areas, the facility would enjoy free peak power from the solar PV array for at least 14 years after the investment is returned. That equates to an $112,000 benefit at today s rates. Either return-scenario grows in value as electricity prices rise, and the avoided cost increases. System Cost After Rebate $72,000 Approximate Power Savings per year $4000 @ $0.10 per kwh Value of System Accelerated Depreciation, per year, for 5 years, at 30% effective CTR Simple Payback Where Avoided Peak Cost is $0.20 per kwh Simple Payback $4320 12.6 years 5.84 years For further information, please contact: Madhu Chawla Communications Coordinator www.nuworldresearch.com 5